Вы находитесь на странице: 1из 2

ON THE WELLHEAD

Simple Installation and Removal .


Adds 6.5 to Wellhead height.
Can adapt to any A.P.A. Wellhead in its
range.
5 No Wellhead Modification Required.
5 No custom built Tubing Hangers
required.
5 Utilizes existing Wellhead Components.
5
5
5

5
5
5
5
5

Can be converted to 3 1/2, 2 7/8 or 2 3/8


EUE by simply changing the Mandrel.
Lower Ring Gasket can be pressure
tested.
Virtually maintenance free.
Can be adapted for thermal applications
up to 210 C.
Components are built to API specifications.

IPS WILL CUSTOM DESIGN AND BUILD


TUBING ROTATORS TO MEET YOUR NEEDS !
COMPOSITE PUMPING TREE
5

Composite Pumping
tree is third party
supplied

Requires non-studded
rotator

CONVENTIONAL WELLHEAD
5

Conventional
Wellhead is third
party supplied

Requires studded
rotator

WELL ASSEMBLY

DOWNHOLE
Prolongs Tubing Life 6-10 times.
Paraffin build-up eliminated. (in most cases)
Rod hang-up eliminated. (in most cases)
Abnormal pump wear eliminated.
Sand build-up in pump barrel
Model CDHS
eliminated.
Downhole Swivel
5 Enhances corrosion inhibitors.
5
5
5
5
5

Model CRTA
Rotating Tubing
Anchor Catcher
The CRTA
Rotating
Anchor
Catcher allows
the entire tubing string
including the
tailpipe and
pump seating
nipple to
rotate while
pulled into tension. This
system is
excellent on
directional or
horizontal
wells where
the anchor is
to be set in
the vertical
section.

The CDHS
Clutched
Downhole
Swivel
Assembly is
designed to be
run in conjunction with the
IPS Tubing
Rotator on
pumping wells
that utilize a
progressive
cavity pump
and an antirotation anchor.

Run with Anti-Rotation


Anchor

Model JDHS
Jay Latch Swivel
The JDHS
Jaylatch Down
Hole Swivel is
designed to be
run in conjunction
with the IPS
Tubing Rotator on
pumping wells
that have a conventional anchor
or packer in
them.

Run on Beam Pump


Wells

CONVENTIONAL
TUBING HANGER

NO TUBING
HANGER

MODIFIED TUBING
HANGER

Run with Conventional


Anchors & Packers

ROTATOR
INSTALLATION

CTR
TUBING ROTATOR
1). Screw Mandrel into the Tubing Hanger

4). Screw Handling Sub into Mandrel

2). Insert Mandrel/Hanger Assembly into the


Wellhead

5). Pick up on Handling Sub and Unseat


hanger

3). Lower Rotator onto Wellhead (FIGURE 1)

6). Install Catch Dogs and Optional Retaining


Ring (FIGURE 2)

NOTE: R ring gasket must be in place. If


Hanger sits flush with wellhead as shown, use
RX ring gasket.

7). Lower Mandrel/Hanger Assembly so


Catch Dogs take the weight

ON THE SURFACE
MANUAL DRIVE

MECHANICAL DRIVE
5
5

Utilizes the Pump Jack


No external power source required

5 Used on
all types of
installations

5
5

Used with Pump Jacks and P.C.P Pumps


Three Phase, Single Phase, or 12 Volt
(Hydraulic Drive is also available)

If Hanger is recessed, use standard R ring


gasket.

8). At this point tubing can be rotated and the


Tubing Hanger is unseated

IPS WILL LOWER YOUR PRODUCTION COSTS


Contact your IPS Representative for more information
INTEGRATED PRODUCTION SERVICES
#1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.ca

INTEGRATED PRODUCTION SERVICES


#1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.ca

ARTIFICIAL LIFT SYSTEMS

NOTE:
Safety Shear Couplings are
incorporated into each drive
system, eliminating the possibility of over-torquing the tubing.

ARTIFICIAL LIFT SYSTEMS

ELECTRIC DRIVE