2000 kg 1 / 2600 kg
Section
Dimensions
45
160
Dimensions
Free space
Free space
80
50
Car data
Page 2
Width dim.
without door
Page 4
100
Approach
Load plan
Headroom according 12
to local regulations
Delimitation
Page 3
Width dim.
with door
Function
Cutting through
Suitable for
Standard passenger cars:
Limousine, station wagon, SUV, van
according to clearance and maximal
surface load.
Standard
Special 3
190 cm 4
190 cm 4
max. 2000 kg max. 2600 kg
wheel load
max. 500 kg max. 650 kg
width
weight
Clearance prole
Page 5
Installation
4
5
6
7
55
45
360 (340) 5
190
185
350 (335)
185
9
10
11
12
car height
upper
lower
200
200
150
200
430 (375)
420 (370)
height
420
(370)
car height
upper
lower
170
170
150
170
2072-220
220
205
210
car height
upper
lower
190
190
150
190
Standard type
Special system: maximum load for extra charge
(maximum load for EB up to 3000 kg per place for extra charge).
To follow the minimum nished dimensions, make sure
to consider the tolerances according to VOB, part C
(DIN 18330 and 18331) and the DIN18202.
Car width for platform width 230 cm. If wider platforms
are used it is also possible to park wider cars.
If a higher ceiling height is available higher cars can
be parked.
For dividing walls: cutting through 10 x 10 cm.
Potential equalization from foundation grounding connection
to system (provided by the customer).
height
360
(340)
height
430
(375)
car height
upper
lower
205
205
150
205
height
400
(360)
car height
upper
lower
165
165
150
165
2072-215
400 (360)
380 (350) 5
1
car height
upper
lower
180
180
150
180
height
350
(335)
2072-205
200
195
height
380
(350)
car height
upper
lower
155
155
150
155
225
height
330
(325)
2072-185
car height
upper
lower
150
150
2072-195
2072-180
175
170
320
170
165
height
320
125
50
330 (325) 5
Description
500 (520)
2072-170
13
100
180
2072-165
15
220
Page 7
10
Water drainage 9
1-2% 1-2%
Technical
data
see table
215
Grounding
Page 6
To be performed by the
customer
30
160
Electrical
installation
Page 2 of 7
Page 2
Width dim.
without door
Page 3
Width dim.
with door
Function
Page 4
Approach
Load plan
EB
DB
B1
B1
B1
260
270
280
290
300
Page 5
EB
DB
B1
B1
490
500
510
520
530
540
550
560
570
Carriageway in
accordance with
local regulations
B1
750
770
790
810
830
840
850
860
870
Installation
B2
B3
Page 7
To be performed by the
customer
DB
DB
B2
B3
EB
DB
EB
DB
min. 20
min. 20
B3
B2
Description
B2
255
265
275
285
295
B3
245
255
265
275
285
B2
485
495
505
515
525
535
545
555
565
B3
475
485
495
505
515
525
535
545
555
max.
30
EB
max.
140
EB
max.
140
Technical
data
max.
140
Page 6
Columns in pit
max.
30
Electrical
installation
B2
745
765
785
805
825
835
845
855
865
B3
735
755
775
795
815
825
835
845
855
min. 20
Carriageway in
accordance with
local regulations
EB
EB
B4
B5
min. 20
B4
250
260
270
280
290
B5
240
250
260
270
280
DB
DB
B4
B5
B4
480
490
500
510
520
530
540
550
560
EB
min. 20
B5
470
480
490
500
510
520
530
540
550
DB
EB
B5
B4
DB
B4
740
760
780
800
820
830
840
850
860
B5
730
750
770
790
810
820
830
840
850
min. 20
Carriageway in
accordance with
local regulations
For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm
for single platforms and 540 for double platforms. Problems may occur if smaller platform widths are used (depending on
car type, access and individual driving behaviour and capability).
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).
Page 3 of 7
Dimensions
Car data
A1 13
Page 2
EB
Page 4
Approach
Load plan
B7
EB
B6
B8
B6
B7
B6
Height
A2 13
Headroom according
to door specifications
B7
Page 3
Width dim.
with door
Function
EB
A3 15
80
Width dim.
without door
B8
Carriageway in accordance
with local regulations
B7
15
15
15
15
15
B8
30
30
30
30
30
Page 5
Installation
Electrical
installation
B7
50
Page 7
To be performed by the
customer
DB
A3
Technical
data
DB
15
DB
Water drainage 14
1-2% 1-2%
Page 6
A3
13
B7
B6
B7
B8
B6
B8
B6
Carriageway in accordance
with local regulations
13
14
15
Description
B7
15
15
15
15
15
15
15
15
15
B8
30
30
30
30
30
30
30
30
30
For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm
for single platforms and 540 for double platforms. Problems may occur if smaller platform widths are used (depending on
car type, access and individual driving behaviour and capability).
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).
Function
System lifted
System lowered
Page 4 of 7
Approach
Dimensions
Car data
Page 2
Width dim.
without door
Page 3
Width dim.
with door
Function
maximum
descending
slope 3 %
Page 4
The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious
maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking
accepts no responsibility.
Approach
Load plan
Page 5
Installation
maximum
ascending
slope 10 %
Load plan
Electrical
installation
F5 F6
F6 F5
F2
Page 6
F2
F3 F4
Technical
data
F5 F6
F6 F5
F3 F4
F4 F3
F2
F4 F3
F2
F6
H1
F4
To be performed by the
customer
F5
F3
Description
F1
F1
F1
F1
10
Page 7
F2
EB
F1
Marking
180
10
290
7,5
520 (540)
platform load
EB 2000 kg
EB 2600 kg
EB 3000 kg
DB 2000 kg
DB 2600 kg
F1
+28
2
+36
2,5
+42
2,9
+51
7,9
+67
10
F2
F3
F4
F5
F6
+12
0,8
1,1
1,1
+15
1,3
1,4
1,4
+17
1,5
1,2
1,6
1,6
+20
1,6
2,6
+26
2,1
3,4
2,6
2,6
18
DB
17
Marking
7,5
7,5
B1 16
Type
2072-165
2072-170
2072-180
2072-185
2072-195
2072-205
2072-215
2072-220
7,5
B1
H1
195
200
210
215
225
235
245
250
17
Marking compliant to ISO 3864 (colors used in this illustration are not ISO 3864 compliant)
18
All forces in kN
17
Page 5 of 7
Installation data Free space for longitudinal and vertical ducts (e.g. ventilation)
Dimensions
19
B1+5
Car data
10
35
Page 2
B1+2,5
B1+2,5
10
35
B1+5
10
35
35
10
Width dim.
without door
30
Page 3
Width dim.
with door
Function
Approach level
20
20
Page 4
Approach
Load plan
Page 5
Installation
EB
EB
DB
DB
Example for ventilation branch
canal and/or vertical pipelines.
max.140
Electrical
installation
Page 6
Technical
data
B2 19
Page 7
B3 19
B2
20
To be performed by the
customer
20
Free space only applicable if vehicle is parked forwards = FRONT FIRST and drivers door on the left side.
Description
19
Electrical installation
Installation diagram
1
2
3
Electricity meter
Main fuse:
4
13
Conduit EN 25 (M25)
height: + 1.70 m
10
Conduit EN 25 (M25)
height: + 1.10 m
120
12
180
11
Position
Frequency
in the supply
line
3 x fuse 16 A (slow)
or circuit breaker 3 x 16 A
(trigger characteristic K or C)
in the supply
line
1 per
3,0 kW
unit
3 x fuse 20 A (slow)
or circuit breaker 3 x 20 A
(trigger characteristic K or C)
in the supply
line
1 per
5,2 kW
unit
1 per unit
to main switch
defined at the
1 per unit
plan evaluation
every
10 m
0,00
14
Description
from main
switch to unit
1 per unit
1 per
system
6
to the next
system
Description
Terminal box
10
Control line 7 x 1.5 mm2 with marked wire and protective conductor
11
Operating device
12
Control line 5 x 1.5 mm2 with marked wire and protective conductor
20
13
14
Control line 5 x 1.5 mm2 with marked wire and protective conductor
20
Page 3
Width dim.
with door
Function
Technical data
Field of application
By default, the system can only be used for a xed number of
users.
If different users use the system only on the upper parking
spaces (e.g. short-time parkers in ofce buildings or hotels)
the Multiparking system needs to be adjusted. If required,
would you please contact us.
Units
Low-noise power units mounted to rubber-bonded-to metal
mountings are installed. Nevertheless we recommend that
parking systems garage be built separately from the dwelling.
Available documents
Page 4
Approach
Load plan
Page 5
Installation
Electrical
installation
Page 6
Technical
data
Environmental conditions
Environmental conditions for the area of multiparking systems:
Temperature range 10 to +40 C. Relative humidity 50% at a
maximum outside temperature of +40 C.
If lifting or lowering times are specied, they refer to an
environmental temperature of +10 C and with the system set
up directly next to the hydraulic unit. At lower temperatures or
with longer hydraulic lines, these times increase.
Sound insulation
Page 7
To be performed by the
customer
Description
Page 6 of 7
Page 2
Width dim.
without door
Safety fences
Any constraints that may be necessary according to DIN EN ISO
13857 in order to provide protection for the park pits for pathways
directly in front, next to or behind the unit. This is also valid during
construction. Railings for the system are included in the series
delivery when necessary.
Numbering of parking spaces
Page 3
Width dim.
with door
Function
Page 4
Approach
Load plan
Page 5
Installation
Electrical
installation
Page 6
Technical
data
Page 7
To be performed by the
customer
Description
Wall cuttings
Any necessary wall cuttings according to page 1.
Electrical supply to the main switch / Foundation earth connector
Suitable electrical supply to the main switch and the control wire
line must be provided by the customer during installation. The
functionality can be monitored on site by our tters together with
the electrician. If this cannot be done during installation for some
reason for which the customer is responsible, the customer must
commission an electrician at their own expense and risk.
In accordance with DIN EN 60204 (Safety of Machinery. Electrical
Equipment), grounding of the steel structure is necessary, provided
by the customer (distance between grounding max. 10 m).
Operating device
Cable conduits and recesses for operating device (for double wing
doors: please contact the local agency of KLAUS Multiparking).
Operating device exposed
110 above
carriageway
level
= =
= =
Strip footings
20
Car data
15
Dimensions
Section
Page 7 of 7
Page 1
Conduit EN 25 (M25)
Marking
According to DIN EN 14010, a warning that identies this
danger area must be placed in the entrance area that conforms
to ISO 3864. This must be done according to EN 92/58/EWG
for systems with a pit (platforms within the pit) 10 cm from the
edge of the pit.
Hydraulic cylinder
Solenoid valve
Safety valve
Hydraulic conduits
Screwed joints
High-pressure hoses
Installation material