Вы находитесь на странице: 1из 7

3G UE TIMERS AND CONFIGURATIONS

3G UE Protocol timers, counters, other


parameters and default configurations
Timers for UE
Timer

Start

Stop

At expiry

T300

Transmission of Reception of RRC


RRC
CONNECTION
CONNECTION SETUP
REQUEST

Retransmit RRC
CONNECTION
REQUEST if V300 =<
N300, else go to Idle
mode

T302

Transmission of
CELL
UPDATE/URA
UPDATE

Retransmit CELL
UPDATE/URA
UPDATE if V302 =<
N302, else, go to Idle
mode

T304

Transmission of Reception of UE
UE CAPABILITYCAPABILITY
INFORMATION INFORMATION
CONFIRM

Retransmit UE
CAPABILITY
INFORMATION if
V304 =< N304, else
initiate a cell update
procedure

T305

Entering
Entering another state.
CELL_FACH or
URA_PCH or
CELL_PCH state.
Reception of
CELL UDPATE
CONFIRM/URA
UPDATE
CONFIRM.

Transmit CELL
UPDATE if T307 is
not activated and the
UE detects in service
area. Otherwise, if
T307 is not active, start
T307.

T307

When the timer When the UE detects Transit to idle mode


T305 has expired in service area.
and the UE
detects out of
service area.

T308

Transmission of

2015-05-10

Reception of CELL
UPDATE
CONFIRM/URA
UPDATE CONFIRM

Not stopped

Transmit RRC

Huawei Proprietary - Restricted Distribution

Page1, Total7

3G UE TIMERS AND CONFIGURATIONS

Timer

Start

RRC
CONNECTION
RELEASE
COMPLETE

Stop

At expiry

CONNECTION
RELEASE
COMPLETE if V308
<=N308, else go to
idle mode.

T309

Upon reception of Successful response to Resume the connection


CELL CHANGE a connection
to UTRAN
ORDER FROM establishment request
UTRAN message in the new cell.

T310

Transmission of
PUSCH
CAPACITY
REQUEST

Reception of
Transmit PUSCH
PHYSICAL SHARED CAPACITY
CHANNEL
REQUEST if V310 =<
ALLOCATION
N310, else procedure
stops.

T311

Reception of
PHYSICAL
SHARED
CHANNEL
ALLOCATION
message with the
CHOICE
PUSCH
allocation set to
PUSCH
allocation
pending.

Reception of
UE may initiate a
PHYSICAL SHARED PUSCH capacity
CHANNEL
request procedure.
ALLOCATION
message with
CHOICE PUSCH
allocation set to
PUSCH allocation
assignment.

T312

When the UE
When the UE detects The criteria for
starts to establish N312 in sync
physical channel
dedicated CH
indication from L1.
establishment failure is
fulfilled

T313

When the UE
When the UE detects The criteria for Radio
detects
consecutive N315 in Link failure is fulfilled
consecutive N313 sync indication from
out of sync
L1.
indication from
L1.

T314

When the criteria When the Cell Update See subclause 8.3.1.13
for radio link
procedure has been
failure are
completed.
fulfilled.

2015-05-10

Huawei Proprietary - Restricted Distribution

Page2, Total7

3G UE TIMERS AND CONFIGURATIONS

Timer

Start

Stop

At expiry

The timer is started


if radio bearer(s)
that are associated
with T314 exist of
if only RRC
connection exists.

T315

When the criteria When the Cell Update See subclause 8.3.1.14
for radio link
procedure has been
failure are
completed.
fulfilled.
The timer is started
only if radio
bearer(s) that are
associated with
T315 exist.

T316

When the UE
When the UE detects
detects out of
in service area.
service area in
URA_PCH or
CELL_PCH state

Initiate cell update


procedure if in service
area is detected.
Otherwise start timer
T317, transit to
CELL_FACH state and
initiate cell update
procedure when the
UE detects in service
area.

T317

When the T316 When the UE detects Transit to idle mode


expires or when in in service area.
CELL_FACH
state, the UE
detects out of
service area.

Counters for UE
2015-05-10

Huawei Proprietary - Restricted Distribution

Page3, Total7

3G UE TIMERS AND CONFIGURATIONS

Counter Reset

Incremented

When reaching max


value

V300

When initiating Upon expiry of T300. When V300 > N300,


the procedure
the UE enters idle
RRC connection
mode.
establishment

V302

When initiating Upon expiry of T302 When V302 > N302


the procedure Cell
the UE enters idle
update or URA
mode.
update

V304

When sending the Upon expiry of T304 When V304 > N304
first UE
the UE initiates the
CAPABILITY
Cell update procedure
INFORMATION
message.

V308

When sending the Upon expiry of T308


first RRC
CONNECTION
RELEASE
COMPLETE
message in a RRC
connection release
procedure.

When V308 > N308


the UE stops retransmitting the RRC
CONNECTION
RELEASE
COMPLETE message.

V310

When sending the Upon expiry of T310


first PUSCH
CAPACITY
REQUEST
message in a
PUSCH capacity
request procedure

When V310 > N310


the UE stops retransmitting the
PUSCH CAPACITY
REQUEST message.

UE constants and parameters


Constant

Usage

N300

Maximum number of retransmissions of the RRC


CONNECTION REQUEST message

2015-05-10

Huawei Proprietary - Restricted Distribution

Page4, Total7

3G UE TIMERS AND CONFIGURATIONS

Constant

Usage

N302

Maximum number of retransmissions of the CELL UPDATE


/ URA UPDATE message

N304

Maximum number of retransmissions of the UE


CAPABILITY INFORMATION message

N308

Maximum number of retransmissions of the RRC


CONNECTION RELEASE COMPLETE message

N310

Maximum number of retransmission of the PUSCH


CAPACITY REQUEST message

N312

Maximum number of in sync received from L1.

N313

Maximum number of successive out of sync received


from L1.

N315

Maximum number of successive in sync received from L1


during T313 is activated.

UE Timer and Constant:


The following settings can only be changed when call status is Idle .

T300 RRC Conn Req Retransmit Timer


This setting determines how long the UE waits for the RRC Connection Setup after
sending an RRC Connection Setup Request.

2015-05-10

Huawei Proprietary - Restricted Distribution

Page5, Total7

3G UE TIMERS AND CONFIGURATIONS

T300 can be set to one of the following values: 400, 600, 800, 1000, 1200, 1400,
1600, 1800, 2000, 3000, 4000, 6000, 8000 ms.

N300 RRC Conn Req Max Retransmits


This setting specifies the maximum number of retransmissions of the RRC
Connection Request message.
N300 can be set to any integer value from 0 to 7.

T312 Link Establishment Timer (Idle)


This setting determines how long the UE waits for an N312 "in-sync" indication from
layer 1 when establishing a dedicated channel and the connection status is Idle. T312
can be set to any integer value from 1 to 15.

T312 Link Establishment Timer (Connected)


This setting determines how long the UE waits for an N312 "in-sync" indication from
layer 1 when establishing a dedicated channel in connected status. The value 0 is not
used.

N312 Link Establishment In-Sync Count (Idle)


This setting specifies the number of " in-syncs" required when establishing a
dedicated channel when the connection status is Idle.
N312 can be set to one of the following values: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600,
800, 1000.

N312 Link Establishment In-Sync Count (Conn.)


This setting specifies the number of " in-syncs" required when establishing a
dedicated channel in connected status.
N312 can be set to one of the following values: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600,
800, 1000.

T313 Out-of-Sync Reception Timer


3GPP TS 25.331 8.5.6 states that after receiving N313 consecutive "out of sync"
indications from layer, the UE shall start the T313 timer. Upon receiving N315
successive "in sync" indications from layer 1, the UE shall stop and reset the T313
timer. If T313 expires, a "Radio Link failure" has occurred, and the UE shall drop the
call.

N313 Successive Out-Of-Sync Reception Max


N313 specifies the maximum number of successive "out of sync" received from L1.
N313 can be set to one of the following integer values: 1, 2, 4, 10, 20, 50, 100, 200.

N315 Successive In-Sync Reception Counter


N315 specifies the maximum number of successive "in sync" received from L1 during
T313 is activated.

2015-05-10

Huawei Proprietary - Restricted Distribution

Page6, Total7

3G UE TIMERS AND CONFIGURATIONS

N315 can be set to one of the following integer values: 1, 2, 4, 10, 20, 50, 100, 200,
400, 600, 800, 1000.

T308 RRC Conn Release Comp Retransmit Timer


T308 specifies the time between the transmissions of RRC Connection Release
Complete message.

N308 RRC Conn Release Comp Max Retransmits


N308 specifies the maximum number of retransmissions of the RRC CONNECTION
RELEASE COMPLETE message.

T3212 Periodic Location Update Timer


T3212 specifies how often the UE will perform the periodic location update
procedure. It is signaled in SIB1.
When T3212 is set to zero, the UE will regard the timer to be infinite.

2015-05-10

Huawei Proprietary - Restricted Distribution

Page7, Total7

Вам также может понравиться