Вы находитесь на странице: 1из 27

Workshop GTZ Eletrobrs

Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

PADRES TCNICOS PARA SISTEMAS FOTOVOLTAICOS


DOMICILIARES NO BRASIL CONCEPO E EXEMPLO DE APLICAO

TECHNICAL STANDARDS FOR SOLAR HOME SYSTEMS IN BRASIL


CONCEPTUAL DESIGN AND APPLICATION EXAMPLE

Roberto Zilles

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

A regulamentao de sistemas fotovoltaicos domiciliares para eletrificao de comunidades isoladas

50 Wp

3,7 kWh/ms

(premissa de 4,0 kWh/m2.dia)

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

SISTEMA FOTOVOLTAICO DOMICILIAR

ESQUEMA UNIFILAR SISTEMA CC

Generador fotovoltaico
Controlador de Carga
Interruptor Geral

Quadro eltrico
Padro de entrada
Contador de
fornecimento

Sistema de acumulao

Interruptor de
Controle de Potncia
(ICP)
Quadro de
distribuio

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

A regulamentao de sistemas fotovoltaicos domiciliares para eletrificao de comunidades isoladas

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

A regulamentao de sistemas fotovoltaicos domiciliares para eletrificao de comunidades isoladas

75 Wp

5,6 kWh/ms
(premissa de 4,0 kWh/m2.dia)
INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

A regulamentao de sistemas fotovoltaicos domiciliares para eletrificao de comunidades isoladas

100 Wp

Gerador fotovoltaico
Abrigo com
acumuladores

7,5 kWh/ms

(premissa de 4,0 kWh/m2.dia)

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

SISTEMA FOTOVOLTAICO DOMICILIAR

ESQUEMA UNIFILAR SISTEMA CC + CA

Generador fotovoltaico

Conversor CC/CA

Controlador de Carga

Interruptor Geral

Quadro eltrico
Padro de entrada
Contador de
Fornecimento CC

Contador de
Fornecimento CA

Sistema de acumulao

Interruptor de
Controle de Potncia (ICP)

Quadro de
distribuio

Interruptor de
Controle de Potncia (ICP)

Quadro de
distribuio

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Resoluo ANEEL N0. 83, SIGFI Sistema de Gerao de Energia Eltrica com Fontes Intermitentes
SISTEMA FOTOVOLTAICO DOMICILIAR

ESQUEMA UNIFILAR
UNIDADE DE CONDICIONAMENTO
DE POTNCIA

Generador fotovoltaico
Controlador de Carga

Interruptor Geral

*
Conversor CC/CA

Protees
Quadro eltrico
Padro de entrada
Contador de
fornecimento

Sistema de acumulao

Interruptor de
Controle de Potncia
(ICP)
Quadro de
distribuio

As protees e as funes do controlador de carga podero estar integradas no conversor CC/CA

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Resoluo ANEEL N0. 83, SIGFI Sistema de Gerao de Energia Eltrica com Fontes Intermitentes

Especificaes tcnicas gerais dos SIGFI.


Classe de
atendimento
SIGFI13
SIGFI30
SIGFI45
SIGFI60
SIGFI80

Consumo dirio de
Referncia
(Wh/dia)
435
1000
1500
2000
2666

Autonomia
mnima
(dias)
2
2
2
2
2

Potncia mnima
disponibilizada*
(W)
250
500
700
1000
1250

Disponibilidade
mensal
(kWh)
13
30
45
60
80

* a tenso de sada, VCA, obedecer aos padres das localidades prximas atendidas pela rede.

PADRES DE QUALIDADE, SIGFI


INDICADOR

Padro de referncia (horas)

DIC mensal

216 horas = 9 dias

DIC anual

648 horas = 27 dias

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

EXEMPLO DE APLICAO
Sistemas Fotovoltaicos Domiciliares
Projeto CT-ENERG/MME/CNPq 03/2003 - Processo CNPq 504601/2003-2

Laboratrio de Sistemas Fotovoltaicos


Instituto de Eletrotcnica e Energia - USP

Instituto DE Desenvolvimento sustentvel mamirau

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

10

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

O Projeto
Eletrificao de 19 residncias em uma comunidade ribeirinha da Amaznia utilizando Sistemas
Fotovoltaicos Domiciliares, tais sistemas se enquadram na Classe de Atendimento SIGFI13,
conforme a Resoluo Normativa ANEEL N 83/2004.

Objetivos especficos
Implementar um modelo de gesto, operao e manuteno dos sistemas
Instalar Sistemas Fotovoltaicos Domiciliares com disponibilidade mensal de 13 kWh/ms
Atendimento em corrente alternada: 127 Vac, senoidal
Monitorar as taxas de falhas e interrupo do servio (DIC mensal e anual)
Monitorar o nvel de satisfao dos usurios
Dar subsdios aos programas de eletrificao usado SIGFI em comunidades ribeirinhas
Divulgar amplamente os resultados
INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

11

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

So Francisco do Aiuc
19 domiclios
Populao 126 habitantes
S. Francisco
do Aiuc

Vila Alencar

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

12

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

13

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Configurao Utilizada: Sistemas Fotovoltaicos Domiciliares

Controlador
de carga 20 A

Inversor de 250 W

=
Disjuntor
10A
2 Painis
(100 Wp cada)

~
conversor CC/CA

Protees

Disjuntor
32 A

Interruptor
Diferencial
30 mA

Medidor de Ah

+ _ + _
Interruptor
Geral 3 A
2 Baterias
em Srie
(150 Ah cada)

Cargas

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

14

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

15

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

16

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Relacionamento com a Comunidade: Discusses sobre o Consumo de Eletricidade


Consumos em kWh/Ms - SFD1
16

13 kWh/Ms

13

12
9

9
6

10
8
4

7
5

0
ago/05

set

out

nov

dez

jan/06

fev

mar

ago/05

abr

Consumo em kWh/Ms - SFD7

set

out

nov

dez

jan/06

fev

mar

abr

Consumos em kWh/Ms - SFD3

16

16

13 kWh/Ms

14

13 kWh/Ms

14
12

10

8
7

8
6

6
5

kWh/Ms

12
kWh/Ms

13 kWh/Ms

13

12

10

10

13

14
kWh/Ms

12
kWh/Ms

16

14

14

10

Consumo em kWh/Ms - SFD17

10
8
6
4

3
2

4
2

fev

mar

0
ago/05

set

out

nov

dez

jan/06

fev

mar

abr

ago/05

set

out

nov

dez

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

jan/06

abr

17

Carga
Instalada
(W)

Consumo Mensal
Consumo Mensal
Consumo Mensal
Workshop GTZ Eletrobrs
Mnimo
Mximo (kWh/ms)
Mdio (kWh/ms)
Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges
(kWh/ms)

Consumo de gua das


Baterias
(Litros)

SFD1

106

6.15

14.22

9.84

<1

SFD2

166

4.47

9.47

7.63

<1

SFD3

55

1.49

3.72

2.76

<1

SFD4

70

0.43

2.81

1.39

<1

SFD5

70

0.85

4.94

2.78

<1

SFD6

175

5.43

14.38

9.52

<1

SFD7

85

1.29

8.35

5.13

<1

SFD8

185

2.67

12.42

5.51

<1

SFD9

161

7.43

4.52

<1

SFD10

314

7.18

15.46

10.47

<1

SFD11

199

8.90

4.99

Maior que 1

SFD12

125

1.95

11.84

7.26

<1

SFD13

130

14.59

7.77

<1

SFD14

211

4.79

11.17

7.89

Maior que 1

SFD15

197

5.55

11.38

8.07

Maior que 1

SFD16

300

5.67

11.16

8.14

Maior que 1

SFD17

198

7.26

13.48

8.88

Maior que 1

SFD18

55

1.57

11.33

6.60

<1

SFD19

80

2.26

12.19

6.51

Maior que 1

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

18

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Quantidade de lmpadas trocadas, interrupes no servio de eletricidade e DIC mensal e anual


dos 19 SFDs entre Agosto de 2005 e Agosto de 2006.

Lmpadas
Trocadas
SFD1
SFD2
SFD3
SFD4
SFD5
SFD6
SFD7
SFD8
SFD9
SFD10
SFD11
SFD12
SFD13
SFD14
SFD15
SFD16
SFD17
SFD18
SFD19

Interrupes
do Servio

DIC mensal
(horas)

DIC anual
(horas)

Disjuntor diferencial

120

120 (5 dias)

Corte automtico

24

24

1 x 20W
1 x 15W

Corte automtico
Conexo no quadro
Corte automtico

24
168
24

24
168 (7 dias)
24

1 x 15W
1 x 20W

Corte automtico
Corte automtico

24
24

24
24

3 x 20W
1 x 15W
1 x 15W
1 x 15W
1 x 15W
2 x 20W
1 x 20W

1 x 15W

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

19

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Objetivos do curso de capacitao dos usurios:


1. Saber identificar os componentes do Sistema Fotovoltaico e suas funes.
2. Identificar as ferramentas e sua utilidade nas tarefas de instalao e manuteno.
3. Conhecer as grandezas eltricas: tenso, corrente, resistncia e potncia.
4. Conhecer os cuidados e procedimentos de segurana (choque eltrico, materiais isolante, condutores).
5. Utilizar o multmetro para medir tenso e continuidade.

1. Verificar com o multmetro os valores de tenso no quadro eltrico, nas tomadas e nas lmpadas do SFD.
2. Aplicar as tarefas associadas manuteno preventiva (reposio da gua da bateria, limpeza e orientao dos painis,
desarmar o interruptor DR, limpeza e ajuste dos terminais das baterias).
3. Solucionar problemas de lmpada queimada, circuito aberto, mau contato, curto-circuito, disjuntor desligado
1. Identificar os sinais no controlador e inversor.
2. Identificar falhas no quadro eltrico; disjuntores, controlador e inversor.
3. Substituir equipamentos do quadro eltrico, disjuntores, controlador e inversor.
4. Saber identificar quais os equipamentos eltricos recomendados para utilizar nos sistemas instalados
1.Substituio de baterias.
1.Instalao de sistemas.

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

20

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

- Qual o custo de operao e manuteno?


IC

10

11

12 13

14 15 16 17

18

19

20

(540)

1
1
1
1
1
1
LCC = 600
600
600
600
600
600
+

(1 + i )18
3
6
9
12
15
(1 + i )
(1 + i )
(1 + i )
(1 + i )
(1 + i )

LCC = 503,40 + 422,40 + 354,60 + 298,20 + 250,20 + 210,00


LCC = 2.038,80

i (1 + i ) n
ALCC =
LCC
n
i
i
+

(
1
)
1

ALCC = 0,0871 2.038,80

ALCC = 166,57 14 R$/ms


INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

21

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Valores referentes ao fundo de O&M dos 19 SFDs na comunidade


So Francisco do Aiuc em Agosto de 2006.

Nmero de Sistemas
Valor da Mensalidade
Nmero de meses
Depsito Inicial da Comunidade
Arrecadado com Mensalidades
Total em Julho de 2006
Valor esperado em Julho de 2006
Inadimplncia total
Inadimplncia mdia por domiclio

19
15 reais
11
2850 reais
2921 reais
5771 reais
5985 reais
214 reais
11,3 reais

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

22

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Sugestes de aperfeioamento Resoluo ANEEL N0. 83, SIGFI

Nova redao

Atuais

DAS DEFINIES
III - Consumo dirio de referncia: quantidade de energia que o SIGFI capaz de fornecer
diariamente calculada a partir da Disponibilidade Mensal Garantida;
IV Disponibilidade Mensal Garantida: quantidade mnima de energia que o SIGFI capaz
de fornecer, em qualquer ms, unidade consumidora;

III - Consumo dirio de referncia: quantidade de energia que o SIGFI capaz de fornecer
diariamente calculada a partir da Disponibilidade Diria Mdia Anual;
IV Disponibilidade Diria Mdia Anual: quantidade de energia primria disponvel para
converso em energia eltrica;

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

23

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

6
5
4
3

= 10o

2
1
0
Jan

Fev

Mar

Abr

Mai

Jun

Jul

Ago

Set

Out

Nov Dez

1
0, 8
0, 6

C ol unas 3D 1

0, 4

C ol unas 3D 2

0, 2

C ol unas 3D 3

Disponibilidade diria mdia, pior ms, 4,1 kWh/m2.dia (10 graus)


Jan

M ar

M ai

Jul

S et

Nov

Disponibilidade diria mdia anual, 4,5 kWh/m2.dia (10 graus)

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

24

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

Disponibilidade diria mdia mdia


anual, 4,5 kWh/m2.dia

Controlador de
Carga

Consumo dirio
de referncia

Gerador
Fotovoltaico
Acumulador

! CERTIFICADO DE DISPONIBILIDADE ENERGTICA !

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

25

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

DAS CONDIES GERAIS DE ATENDIMENTO


1o A concessionria poder utilizar SIGFI com Disponibilidade Mensal Garantida
superior a 80 kWh/ms, desde que garantida uma autonomia mnima de 2 dias.
2o Os componentes do SIGFI e demais equipamentos necessrios para o fornecimento
de energia eltrica unidade consumidora devem ser fornecidos e instalados sob a
responsabilidade e s expensas da concessionria, de acordo com regulamentao
vigente que estabelece a responsabilidade pelo atendimento a pedidos de fornecimento.

Incluir

3o Os componentes do SIGFI devem atender s exigncias das normas expedidas


pelos rgos oficiais competentes, pelo Programa Brasileiro de Etiquetagem do Instituto
Nacional de Metrologia(INMETRO) ou outra organizao credenciada pelo Conselho
Nacional de Metrologia, Normalizao e Qualidade Industrial(CONMETRO).
4o O SIGFI dever possuir certificado de aprovao em teste operacional de
comprovao da disponibilidade energtica conforme especificado pelo Programa
Brasileiro de Etiquetagem do Instituto Nacional de Metrologia(INMETRO) ou outra
organizao credenciada pelo Conselho Nacional de Metrologia, Normalizao e
Qualidade Industrial(CONMETRO).
.

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

26

Workshop GTZ Eletrobrs


Photovoltaics in Rural Electrification Experiences, Opportunities and Challenges

INSTITUTO DE ELETROTCNICA E ENERGIA - LABORATRIO DE SISTEMAS FOTOVOLTAICOS

27

Вам также может понравиться