Вы находитесь на странице: 1из 6

Return to Pumps

D1400N Pump
400 Series, Min. Casing Size 512-in. [139.7-mm] OD
Carbon Steel

ES Carbon Steel

ARZ Carbon Steel

Housing

Length,
ft [m]

Weight,
lbm [kg]

Max.
Stages

FL-CT
Part Number

Max.
Stages

FL-CT-ES
Part Number

Max.
Stages

FL-CT-ARZ
Part Number

10
20
30
40
50
60
70
80
90
100
110
120

2.1 [0.64]
3.5 [1.07]
4.9 [1.49]
6.3 [1.92]
7.7 [2.35]
9.1 [2.78]
10.5 [3.20]
11.9 [3.63]
13.3 [4.06]
14.7 [4.48]
16.1 [4.91]
17.5 [5.34]

45 [20.4]
75 [34.1]
105 [47.7]
135 [61.3]
165 [74.9]
195 [88.5]
225 [102.2]
255 [115.8]
285 [129.4]
315 [143.0]
345 [156.6]
375 [170.3]

17
36
54
73
92
110
129
147
166
184
202
221

tba
tba
tba
1346386
2005388
tba
1326156
1326164
1328103
1315571
1334176
1328111

17
36
54
73
92
110
129
147
166
184
202
221

tba
tba
tba
tba
100030084
2004453
tba
tba
100023140
100023147
D334176
tba

13
29
45
61
78
94
110
127
143
160
176
192

tba
tba
tba
tba
tba
2006230
2006228
tba
tba
tba
tba
tba

to

be assigned

Pumps

D1400N Pump

2005 Schlumberger. All rights reserved.

Return to Pumps

Return to Pumps

D1400N Pump, 400 Series, Tandem Combinations


Tandem Housing SectionsNumber
Pump
Housing

Number
of Stages

60

70

130
140
150
160
170
180
190
200
210
220
230

239
258
276
294
313
332
351
370
387
404
423

1
2
1

80

1
2
1

90

1
2
1

100

1
2
1

110

120

1
2
1

Note: Stage counts are for FL-CT-ES pumps.


Requires use of buttress threads in uppermost pump
Requires use of high-strength shaft in lowermost pump

ESP Catalog

2005 Schlumberger. All rights reserved.

Return to Pumps

Pumps

D1400N Pump

Head
(ft)

500

750

1,000

1,500

1,750

125 hp
200 hp
5,000 psi
6,000 psi
6,000 psi

3.00

Power
(hp)

250

Power

2005 Schlumberger. All rights reserved.


*Mark of Schlumberger

Return to Pumps

This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.

Capacity (B/D)

1,250

0
2,000

0.50

1.00

1.50

10

15

2.00

Operating range

Standard
High strength
Standard
Buttress
Welded

60 Hz, 3,500 rpm

20

Efficiency

Housing burst-pressure limit

Shaft brake-power limit

Curve computed for one stage in fluid of 1.00 sg.

2.50

Head

9601,700 B/D
4.00 in.
0.688 in.
0.371 in.2
5.500 in.

Return to Pumps
D1400N Pump Performance Curve

25

30

Optimum operating range


Nominal housing diameter
Shaft diameter
Shaft cross-sectional area
Min. casing size

REDA* ESP

10

20

30

40

50

60

Efficiency
(%)

Return to Pumps

REDA* Pump D1400N Performance Curve


Curve computed for one stage in fluid of 1.00 sg.

40
70 Hz

35

65 Hz

30

Head
(ft)

60 Hz

25

55 Hz
20
50 Hz
15
10
5

70 Hz

0.50
65 Hz

0.40
Power
(hp)

60 Hz

0.30
55 Hz
0.20

50 Hz

0.10

250

500

750

1,000

1,250

1,500

1,750

2,000

2,250

2,500

Capacity (B/D)

2005 Schlumberger. All rights reserved.


*Mark of Schlumberger

ESP Catalog

Return to Pumps

Pumps

D1400N Pump

Head
(m)

25

75

100

125

150

200

225

250

104 hp
167 hp
34,475 kPa
41,370 kPa
41,370 kPa

3.00

Power
(hp)

0
Capacity (m3d)

2005 Schlumberger. All rights reserved.


*Mark of Schlumberger

Return to Pumps

This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.

50

Power
175

0
275

0.50

1.00

2.00

1.00

1.50

3.00

2.00

Operating range

Standard
High strength
Standard
Buttress
Welded

50 Hz, 2,917 rpm

4.00

Efficiency

Housing burst-pressure limit

Shaft brake-power limit

Curve computed for one stage in fluid of 1.00 sg.

2.50

Head

127225 m3 d
10.16 cm
1.75 cm
2.39 cm2
13.97 cm

Return to Pumps
D1400N Pump Performance Curve

5.00

6.00

Optimum operating range


Nominal housing diameter
Shaft diameter
Shaft cross-sectional area
Min. casing size

REDA* ESP

10

20

30

40

50

60

Efficiency
(%)

Return to Pumps

REDA* Pump D1400N Performance Curve


Curve computed for one stage in fluid of 1.00 sg.

12.50

70 Hz
10.00
65 Hz
Head
(m)

60 Hz
7.50
55 Hz
50 Hz
5.00

2.50

70 Hz

0.50
65 Hz

0.40
Power
(hp)

60 Hz

0.30
55 Hz
0.20

50 Hz

0.10

50

100

150

200

250

300

350

400

Capacity (m3/d)

2005 Schlumberger. All rights reserved.


*Mark of Schlumberger

ESP Catalog

Return to Pumps

Вам также может понравиться