Академический Документы
Профессиональный Документы
Культура Документы
Introduction: A pulverized coal combustion simulation involves modeling a continuous gas phase flow field and its interaction with a discrete phase of coal particles. The coal particles, traveling through
the gas, will devolatilize and undergo char combustion, creating a
source of fuel for reaction in the gas phase. Reaction can be modeled using either the species transport model or the non-premixed
combustion model. In this tutorial you will model a simplified coal
combustion furnace using the non-premixed combustion model for
the reaction chemistry.
In this tutorial you will learn how to:
Prepare a PDF table for a pulverized coal fuel using the
prePDF preprocessor
Define FLUENT inputs for non-premixed combustion chemistry modeling
Define a discrete second phase of coal particles
Solve a simulation involving reacting discrete phase coal particles
The non-premixed combustion model uses a modeling approach
that solves transport equations for one or two conserved scalars,
the mixture fractions. Multiple chemical species, including radicals
and intermediate species, may be included in the problem definition and their concentrations will be derived from the predicted
mixture fraction distribution. Property data for the species are
accessed through a chemical database and turbulence-chemistry
interaction is modeled using a Beta or double-delta probability
density function (PDF). See the Users Guide for more detail on
the non-premixed combustion modeling approach.
12-1
Prerequisites: This tutorial assumes that you are familiar with the
menu structure in FLUENT, and that you have solved Tutorial 1
or its equivalent. Some steps in the setup and solution procedure
will not be shown explicitly.
Problem Description: The coal combustion system considered in this
tutorial is a simple 10 m by 1 m two-dimensional duct depicted in
Figure 12.1. Only half of the domain width is modeled because
of symmetry. The inlet of the 2D duct is split into two streams.
A high-speed stream near the center of the duct enters at 50 m/s
and spans 0.125 m. The other stream enters at 15 m/s and spans
0.375 m. Both streams are air at 1500 K. Coal particles enter the
furnace near the center of the high-speed stream with a mass flow
rate of 0.1 kg/s (total flow rate in the furnace is 0.2 kg/s). The duct
wall has a constant temperature of 1200 K. The Reynolds number
based on the inlet dimension and the average inlet velocity is about
100,000. Thus, the flow is turbulent.
Details regarding the coal composition and size distribution are
included in Step 5: Models: Continuous (Gas) Phase and Step 8:
Materials: Discrete Phase.
12-2
T = 1200 K
w
0.5 m
Coal Injection: 0.1 kg/s
0.125 m
12-3
(a) Under Heat transfer options, keep the default setting of Adiabatic.
The coal combustor studied in this tutorial is a non-adiabatic
system, with heat transfer at the combustor wall and heat
12-4
transfer to the coal particles from the gas. Therefore, a nonadiabatic combustion system must be considered in prePDF.
Because non-adiabatic calculations are more time-consuming
than those for adiabatic systems, you will start the prePDF
setup by considering the results of an adiabatic system. By
computing the PDF/equilibrium chemistry results for the adiabatic system, you will determine appropriate system parameters that will make the non-adiabatic calculation more efficient. Specifically, the adiabatic calculation will provide information on the peak (adiabatic) flame temperature, the stoichiometric mixture fraction, and the importance of individual
components to the chemical system. This process of beginning with an adiabatic system calculation should be followed
in all PDF calculations that ultimately require a non-adiabatic
model.
(b) Under Chemistry models, keep the default setting of Equilibrium Chemistry.
In most PDF-based simulations, the Equilibrium Chemistry option is recommended. The Stoichiometric Reaction (mixed is
burned) option requires less computation but is generally less
accurate. The Laminar Flamelets option offers the ability to
include aerodynamic strain induced non-equilibrium effects,
such as super-equilibrium radical concentration and
sub-equilibrium temperatures. This can be important for NOx
prediction, but is excluded here.
(c) Keep the default setting of the PDF models.
The Beta PDF integration is always recommended because it
is more accurate than the Delta PDF approach.
(d) Under Empirically Defined Streams, enable the Fuel stream option.
This will allow you to define the fuel stream using the empirical input option. The empirical input option allows you to
define the composition in terms of atom fractions of H, C, N,
and O, along with the lower heating value and heat capacity
12-5
12-6
You should include both C and C(S) in the system when the
empirical input option is used.
(a) Set the Maximum # of Species to 13. Use the up and down
arrows to set the maximum number of species, or enter the
number in the text field followed by <ENTER>.
(b) Select the top species in the Defined Species list (initially labeled UNDEFINED).
12-7
(c) In the Database Species drop-down list, use the slider bar to
scroll the list, and select C. The Defined Species list now shows
C as the first entry.
(d) Select the next species in the Defined Species list (or increment
the Species # counter to 2).
(e) In the Database Species drop-down list, use the slider bar to
scroll the list, and select the next species (C(S)).
(f) Repeat steps (d) and (e) until all 13 species are defined.
(g) Click Apply and then close the panel.
Note: In other combustion systems, you might want to include additional chemical species, but you should not add slow chemical species like NOx .
3. Determine the fuel composition inputs.
The fuel considered here is known, from proximate analysis, to
consist of 28% volatiles, 64% char, and 8% ash. You will use this
information, along with the ultimate analysis given below, to define
the coal composition in prePDF. The fuel stream composition (char
and volatiles) is derived as follows.
Begin by converting the proximate data to a dry-ash-free basis:
Proximate Analysis
Volatiles
Char (C(s))
Ash
Wt %
(dry)
28
64
8
Wt %
(DAF)
30.4
69.6
-
Wt % (DAF)
89.3
5.0
3.4
1.5
0.8
For modeling simplicity, the sulfur content of the coal can be combined into the nitrogen mass fraction, to yield:
Element
C
H
O
N
S
Wt % (DAF)
89.3
5.0
3.4
2.3
-
Wt %
89.3
5.0
3.4
2.3
Moles
7.44
5
0.21
0.16
12.81
Mole Fraction
0.581
0.390
0.016
0.013
You will enter the mole fractions in the final column, above, in
order to define the fuel composition. prePDF will use this information, along with the coal heating value, to define the species present
in the fuel.
The lower heating value of coal (DAF) is known to be:
LCVcoal,DAF = 35.3 MJ/kg
The specific heat and density of the coal are known to be 1000 J/kgK and 1 kg/m3 respectively.
12-9
iv. Select N2 in the Defined Species list and enter 0.79 in the
Species Fraction field.
(b) Enable the input of the fuel stream composition.
Note: Because the empirical input option is enabled for the
fuel stream, you will be prompted to enter atom mole fractions for C, H, O, and N, along with the heating value and
heat capacity of the coal.
12-11
iii. Select C in the Defined Species list and enter 0.581 in the
Atom Fraction field.
iv. Select H in the Defined Species list and enter 0.390 in the
Atom Fraction field.
v. Select N in the Defined Species list and enter 0.016 in the
Atom Fraction field.
vi. Select O in the Defined Species list and enter 0.013 in the
Atom Fraction field.
vii. Enter 3.53e7 J/kg for the Lower Caloric Value and 1000
J/kg-K for the Specific Heat.
viii. Click Apply and close the panel.
5. Define the density of the solid carbon.
Here, a value of 1300 kg/m3 is assumed.
Setup Species Density...
12-12
12-13
(a) Enter 400 K and 1500 K as the Fuel and Oxidiser inlet temperatures.
(b) Click Apply and close the panel.
12-14
Step 2: Compute and Review the Adiabatic System prePDF Look-Up Tables
1. Accept the default PDF solution parameters.
Setup Solution Parameters...
12-15
12-16
(a) Select TEMPERATURE from the Plot Variable list and then
click Display to generate the table (Figure 12.2).
12-17
The temperature display shows how the time-averaged system temperature varies with the mean mixture fraction and
its variance.
The temperature/mixture-fraction relationship shows that the
peak flame temperature is about 2750 K at fuel stoichiometric mixture fractions of approximately 0.1. The relatively high
flame temperature is a result of the high pre-heat in the combustion air.
Note: The adiabatic flame temperature predicted by the adiabatic system calculation will be used to select the maximum temperature in the non-adiabatic system calculation.
2.8E+03
2.4E+03
T
E
M
P
E
R
A
T
U
R
E
2.0E+03
2.50E-01
2.00E-01
1.6E+03
1.50E-01
SCALED-F-VARIANCE
1.00E-01
1.2E+03
5.00E-02
7.6E+02
0.00E+00
0.00E+00
2.00E-01
4.00E-01
6.00E-01
8.00E-01
1.00E+00
F-MEAN
prePDF V4.00
Fluent Inc.
12-18
12-19
(a) Select Non-Adiabatic under Heat transfer options and click Apply.
12-20
12-21
(a) Enter 298 for Min. Temperature and 3000 for Max. Temperature.
(b) Click Apply and close the panel.
3. Save the non-adiabatic system inputs (coal.inp).
File Write Input...
4. Compute the non-adiabatic PDF look-up tables.
Calculate PDF Table
The non-adiabatic prePDF calculation requires much more computation than the adiabatic calculation. prePDF begins by accessing
the thermodynamic data from the database. Next, the enthalpy
12-22
12-23
12-24
2.8E+03
2.4E+03
T
E
M
P
E
R
A
T
U
R
E
2.0E+03
2.50E-01
2.00E-01
1.6E+03
1.50E-01
SCALED-F-VARIANCE
1.00E-01
1.2E+03
5.00E-02
7.6E+02
0.00E+00
0.00E+00
2.00E-01
4.00E-01
6.00E-01
8.00E-01
1.00E+00
F-MEAN
prePDF V4.00
Fluent Inc.
12-25
12-26
7.6E-01
6.1E-01
M
O
L
E
F
R
A
C
T
I
O
N
4.6E-01
2.50E-01
2.00E-01
3.1E-01
1.50E-01
SCALED-F-VARIANCE
1.00E-01
1.5E-01
5.00E-02
0.0E+00
0.00E+00
0.00E+00
2.00E-01
4.00E-01
6.00E-01
8.00E-01
1.00E+00
F-MEAN
prePDF V4.00
FROM 3D-PDF-TABLE
Fluent Inc.
Non-Adiabatic
3.1E-01
2.4E-01
M
O
L
E
F
R
A
C
T
I
O
N
1.8E-01
2.50E-01
2.00E-01
1.2E-01
1.50E-01
SCALED-F-VARIANCE
1.00E-01
6.1E-02
5.00E-02
0.0E+00
0.00E+00
0.00E+00
2.00E-01
4.00E-01
6.00E-01
8.00E-01
1.00E+00
F-MEAN
FROM 3D-PDF-TABLE
prePDF V4.00
Fluent Inc.
12-27
12-28
Step 4: Grid
1. Read the 2D mesh file, coal.msh.
File Read Case...
The FLUENT console window reports that the mesh contains 1357
quadrilateral cells.
2. Check the grid.
Grid Check
The grid check should not report any errors or negative volumes.
3. Display the grid (Figure 12.6).
Display Grid...
Due to the grid resolution and the size of the domain, you may find
it more useful to display just the outline, or to zoom in on various
portions of the grid display.
Note: You can use the mouse probe button (right button, by default) to find out the boundary zone labels. As annotated in
Figure 12.7, the upstream boundary contains two velocity inlets (for the low-speed and high-speed air streams), the downstream boundary is a pressure outlet, the top boundary is a
wall, and the bottom boundary is a symmetry plane.
12-29
Grid
wall-7
velocity-inlet-2
velocity-inlet-8
symmetry-5
Grid
12-30
12-31
Note: As indicated in the problem description, the Reynolds number of the flow is about 105 . Thus, the flow is turbulent and
the high-Re k- model is suitable.
12-32
When you click OK, FLUENT will open the Select File dialog
box, requesting input of the PDF file to be used in the simulation.
(b) In the Select File dialog box, select and read the non-adiabatic
PDF file (coal.pdf).
FLUENT reports in the console window that it is reading the
nonadiabatic PDF file containing 13 species. It also reports
that a new material, called pdf-mixture, has been created. This
mixture contains the 13 species that you defined in prePDF and
their thermodynamic properties.
FLUENT will present an Information dialog box telling you that
available material properties have changed. You will be setting
properties later, so you can simply click OK in the dialog box
to acknowledge this information.
Note: FLUENT will automatically activate solution of the energy equation when it reads the non-adiabatic PDF file, so
you do not need to visit the Energy panel to enable heat
transfer.
12-33
The P-1 model is one of the radiation models that can account for
the exchange of radiation between gas and particulates.
After you click OK, FLUENT will present an Information dialog box
telling you that available material properties have changed. You
will be setting properties later, so you can simply click OK in the
dialog box to acknowledge this information.
12-34
12-35
12-37
12-38
In the Set Injection Properties panel you will define the initial
conditions of the flow of coal particles. The particle stream
will be defined as a group of 10 distinct initial conditions,
all identical except for diameter, which will obey the RosinRammler size distribution law.
(b) Select group in the Injection Type drop-down list.
12-39
12-40
12-41
12-42
This panel can be used to copy and delete injection definitions. You can also select an existing injection and list the
initial conditions of particle streams defined by that injection
in the console window. The listing for the injection-0 group
will show 10 particle streams, each with a unique diameter
between the specified minimum and maximum value, obtained
from the Rosin-Rammler distribution, and a unique mass flow
rate.
12-43
12-44
12-45
12-46
This is the combusting particle material type that you selected from
the list of database options in the Set Injection Properties panel.
Additional combusting particle materials can be copied from the
property database, if desired. You can click the Database... button
in order to view the combusting-particle materials that are available.
Here, you will simply modify the property settings for the selected
material, coal-mv.
3. Set the following constant property values for the coal-mv material:
Density
Cp
Thermal Conductivity
Latent Heat
Vaporization Temperature
Volatile Component Fraction (%)
Binary Diffusivity
Particle Emissivity
Particle Scattering Factor
Swelling Coefficient
Burnout Stoichiometric Ratio
Combustible Fraction (%)
1300 kg/m3
1000 J/kg-K
0.0454 w/m-k
0
400 K
28
5e-4 m2/s
0.9
0.6
2
2.67
64
12-47
12-48
The settings for the Vaporization Temperature, Combustible Fraction, and Volatile Component Fraction inputs should all be
consistent with your prePDF inputs. (See Step 1: Define the
Preliminary Adiabatic System in prePDF.)
12-49
12-50
12-51
2. Set the following conditions for the velocity-inlet-8 zone (the highspeed inlet boundary).
12-52
3. Set the following conditions for the pressure-outlet-6 zone (the exit
boundary).
The exit gauge pressure of zero simply defines the system pressure
at the exit to be the operating pressure. The backflow conditions
for scalars (temperature, mixture fraction, turbulence parameters)
will be used only if flow is entrained into the domain through the
exit. It is a good idea to use reasonable values in case flow reversal
occurs at the exit at some point during the solution process.
12-53
12-54
The Apply button does not initialize the flow field data. You
must use the Init button. (Apply simply allows you to store
your initialization parameters for later use.)
Note: Here, with very high pre-heat of the oxidizer stream, you
can start the combustion calculation from the inlet-based initialization. In general, you may need to start your coal combustion calculations by patching a high-temperature region and
12-55
performing a discrete phase trajectory calculation. This provides the initial volatile and char release required to initiate
combustion. The Solve/Initialize/Patch... menu item and the
solve/dpm-update text command can be used to perform this
initialization.
3. Enable the display of residuals during the solution process.
Solve Monitors Residual...
4. Save the case file (coal.cas).
File Write Case...
5. Begin the calculation by requesting 400 iterations.
Solve Iterate...
12-56
12-57
2.26e+03
2.16e+03
2.05e+03
1.94e+03
1.84e+03
1.73e+03
1.63e+03
1.52e+03
1.41e+03
1.31e+03
1.20e+03
12-58
12-59
3.72e-02
3.35e-02
2.98e-02
2.61e-02
2.23e-02
1.86e-02
1.49e-02
1.12e-02
7.45e-03
3.72e-03
0.00e+00
12-60
(a) Select Discrete Phase Model... and DPM Evaporation/Devolatilization in the drop-down lists under Contours Of.
4. Display the char burnout rate (Figure 12.11) by selecting DPM
Burnout from the lower drop-down list.
Note: The display of devolatilization rate shows that volatiles are
released after the coal travels about one eighth of the furnace length. (The onset of devolatilization occurs when the
coal temperature reaches the specified value of 400 K.) The
char burnout occurs following complete devolatilization. Figure 12.11 shows that burnout is complete at about three-quarters
of the furnace.
12-61
2.95e-03
2.66e-03
2.36e-03
2.07e-03
1.77e-03
1.48e-03
1.18e-03
8.86e-04
5.90e-04
2.95e-04
0.00e+00
4.42e-04
3.97e-04
3.53e-04
3.09e-04
2.65e-04
2.21e-04
1.77e-04
1.32e-04
8.83e-05
4.42e-05
0.00e+00
12-62
12-63
3.63e-01
3.27e-01
2.90e-01
2.54e-01
2.18e-01
1.81e-01
1.45e-01
1.09e-01
7.26e-02
3.63e-02
0.00e+00
12-64
Note: Although transport equations are solved only for the mixture
fraction and its variance, you can still display the predicted
chemical species concentrations. These are predicted by the
PDF equilibrium chemistry model.
7. Select other species and display their mass fraction distributions
(e.g., Figures 12.1412.16).
12-65
2.33e-01
2.22e-01
2.11e-01
2.00e-01
1.89e-01
1.78e-01
1.67e-01
1.56e-01
1.45e-01
1.34e-01
1.23e-01
12-66
1.60e-02
1.44e-02
1.28e-02
1.12e-02
9.62e-03
8.02e-03
6.42e-03
4.81e-03
3.21e-03
1.60e-03
0.00e+00
12-67
12-68
heat of formation of the chemical species). Here, the net imbalance of total enthalpy (about 14 KW) represents the total
enthalpy addition from the discrete phase.
2. Compute the volume sources of heat transferred between the gas
and discrete particle phase.
Report Volume Integrals...
12-69
12-70
Number
---Incomplete
-----100
Fate
---Incomplete
Fate
---Incomplete
Done.
The report shows that the average residence time of the coal particles is about 0.33 seconds. Volatiles are completely released within
the domain and the char conversion is 100% .
Extra: You can obtain a detailed report of the particle position, velocity,
diameter, and temperature along the trajectories of individual particles. This type of detailed track reporting can be useful if you are
trying to understand unusual or important details in the discrete
model behavior. To generate the report, visit the Particle Tracks
panel. Select Step By Step under Report Type, and File under Report to. Enable the Track Single Particle Stream option, and set the
Stream ID to the desired particle stream. Clicking Track will bring
12-71
up the Select File dialog box, where you will enter the name of the
file to be written. This file can then be viewed with a text editor.
12-72