Вы находитесь на странице: 1из 45

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES

N11

N9

N8

N5

Bla

N6

BLr

Bla

dh

Ha
V1
Y1

Y2

N1

Vt
N2

Vo

D
N4

0.10

st= 0.02

L=

Caractersticas del Canal Alimentador


Caudal (m3/s)
Qa =
Ancho de Base (m)
ba =
Talud
Z =
Pendiente (m/m)
Sa =
Rugosidad
n =
Altura de agua (m)
Y1 =
Velocidad (m/s)
V1 =
Carga de velocidad (m) :V1^2/2*g hv1 =
Altura de Canal (m) Ha =
0.84 ~

N7

N3

9.00

Lt = 3.00

Canal de Derivacin
0.625
0.400
1.500

Caudal (m3/s)
Ancho de Base (m)
Talud
Pendiente (m/m)
Rugosidad
Altura de agua (m)
Velocidad (m/s)
Carga de velocidad (m)
Altura de Canal (m)

0.0005

0.014
0.63
0.74
0.04
0.85

Qa =
ba =
Z =
Sd =
n =
Y2 =
V2 =
hv2 =
Hd =

0.185
0.300
1.500
0.0005

0.014
0.40
0.55
0.03
0.53

Sabemos que la velocidad en el conducto de la estructura de toma debe ser similar a la del canal derivado,
es decir, Vt = Vd; por lo tanto :
A (m2) : Qa / V2

0.336

Luego se har un tanteo para escoger la compuerta que se ajuste a una seccin cuadrada o tubera de tal
manera que nos permita pasar el caudal sin prdidas apreciables.
Probaremos con una compuerta deslizante Tipo ARMCO Modelo 5.00 de :
y un tubo de dimetro D =
24 pulgadas =
0.61 m
Area del Tubo (m2) : * D^2 / 4

At =

0.29

Velocidad en el tubo (m/s) : Qd / At

Vt =

0.63

>

0.55

24

24

pulgadas

OK !

Nota : En el caso que la velocidad Vt > Vd, se aumentar el dimetro hasta que : Vt ~ Vd
Como esta velocidad " Vt " es similar a la del canal derivado, podemos pasar a calcular las prdidas de carga :
dh (m) : (Vt^2 / 19.62) * [1 + (0.78 / Cc^2) + f * (L / D)]

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


Coeficiente de Contraccin en la Tubera : Cc =
0.644 (valor normal, cuando la toma es perpendicular al canal)
Factor de friccin
f =
0.0190 (en el cuadro, con D
24 " y
Vt =
0.63
Reemplazando valores en la frmula, se tiene :

Asumimos :

dh =
dh =

0.064
0.07

(prdida de carga en la toma)

El valor de " dh ", se aproxima por encima ya que de haber aproximado dh =


garanta de que va a pasar el caudal necesario; en tanto que aproximando a :
y podr controlarse con la compuerta

0.06 m, no tendramos
0.07 m, el caudal aumentar

Determinada la prdida de carga en la toma (dh), pasaremos a esquematizarla.


Cota de Rasante de fondo de Canal Alimentador " N1 ", en (msnm)
Supongamos un valor de :

N1 =

99.669

Nivel d' Agua Canal Alimentador:N1+Y1

N5 =

100.299

Cota de Rasante de fondo de Canal Derivado " N4 ", en (msnm)


N7 = N5 - dh - Y2

N7 =

99.829

Con el fin de obtener una medicin del caudal bastante aproximada, la sumergencia " S " debe ser igual al
dimetro del conducto, es decir : S = D; por lo tanto se tiene que la :
Cota de Captacin : N5 - 2 * D

N3 =

99.079

Se asume un valor de 0.10 m, por el empotramiento de la compuerta


Cota del escaln : N3 - 0.10

N2 =

98.979

Nivel d' Agua Canal Derivado : N1 - dh

N6 =

99.599

Cota:salida del conducto : N3 - L * St

N4 =

98.899

Altura del Relleno (m)


Altura del canal alimentador (m)

BLr =
Ha =

0.20
0.85

Nivel de subrasante (msnm)

N8 =

100.719

Bordo libre de afirmado (m)

Bla =

0.20

Nivel de Carretera C. Alimen. (msnm)

N9 =

100.919

N8 = N1 + BLr + Ha

N9 = N8 + Bla

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


N10 = N7 + Hd + Blr
Altura del canal derivado (m)
Bordo libre de afirmado (m)

Hd =
BLr =

0.55
0.20

Nivel de Carretera C. Derivado (msnm)

N10 = 100.579

N11 = N3 + (D / 2) + H
Valor obtenido del manual Compuertas de Control Tipo ARMCO; para compuertas Modelo 5.00 y
Tamao d' Abertura:
24 x 24
pulgadas, se tiene
H=
4 a 8
pies
tomaremos : H =

5.5 pies
H=

1.68

Nivel superior de la pantalla de concreto (N11) donde se empotra la compuerta


N11 = 101.064

>

N9 =

100.919

OK !

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES

ALES
Pg 1

N10

Hd

V2
N7

0.55

Valores de " f " para Tuberas Lisas y Limpias de Hierro Colado, de Acero y de Concreto
Dimetro
pulgadas

rdidas de carga :

(Pulg)

(m)

0.30
f

4
5
6
8
10
12
14
16
18
20
24
30

0.10
0.13
0.15
0.20
0.25
0.30
0.36
0.41
0.46
0.51
0.61
0.76

0.0285
0.0275
0.0265
0.0255
0.0245
0.0235
0.0233
0.0228
0.0220
0.0215
0.0210
0.0200

0.61

0.91

0.0255
0.0245
0.0240
0.0230
0.0220
0.0215
0.0210
0.0205
0.0200
0.0195
0.0190
0.0185

0.0240
0.0230
0.0225
0.0215
0.0205
0.0200
0.0197
0.0194
0.0190
0.0185
0.0180
0.0175

Velocidad ( Vt ) en m/s
1.22
1.52
1.83
2.44
0.0230
0.0225
0.0215
0.0205
0.0200
0.0190
0.0188
0.0185
0.0180
0.0175
0.0170
0.0165

0.0225
0.0215
0.0210
0.0200
0.0190
0.0185
0.0183
0.0180
0.0175
0.0170
0.0165
0.0160

0.0220
0.0210
0.0200
0.0195
0.0185
0.0180
0.0178
0.0175
0.0170
0.0165
0.0160
0.0155

0.0210
0.0200
0.0195
0.0185
0.0180
0.0175
0.0170
0.0167
0.0165
0.0160
0.0155
0.0150

3.05
0.0200
0.0195
0.0190
0.0180
0.0175
0.0170
0.0165
0.0162
0.0160
0.0155
0.0150
0.0145

ALES

pendicular al canal)

m/s)

Pg 2

caudal aumentar

36
42
48
60
72
84
96

0.91
1.07
1.22
1.52
1.83
2.13
2.44

0.0195
0.0190
0.0185
0.0180
0.0175
0.0170
0.0165

0.0180
0.0175
0.0170
0.0165
0.0160
0.0155
0.0150

0.0170
0.0165
0.0160
0.0155
0.0150
0.0145
0.0140

0.0160
0.0155
0.0155
0.0150
0.0145
0.0140
0.0135

0.0155
0.0150
0.0150
0.0145
0.0140
0.0135
0.0130

0.0150
0.0145
0.0145
0.0140
0.0135
0.0130
0.0125

0.0145
0.0140
0.0140
0.0135
0.0130
0.0125
0.0120

Fuente : " Hidrulica " , de George E. Russell, pg. 231, sexta edicin 1976

0.0140
0.0135
0.0135
0.0130
0.0125
0.0120
0.0120

ALES

Pg 3

ALES

Lisas y Limpias de Hierro Colado, de Acero y de Concreto


Velocidad ( Vt ) en m/s
4.57

6.10

0.0190
0.0185
0.0175
0.0170
0.0165
0.0160
0.0155
0.0152
0.0150
0.0145
0.0140
0.0135

0.0180
0.0175
0.0170
0.0160
0.0155
0.0150
0.0148
0.0145
0.0140
0.0140
0.0135
0.0130

0.0130
0.0130
0.0125
0.0120
0.0120
0.0115
0.0110

0.0125
0.0125
0.0120
0.0115
0.0115
0.0110
0.0105

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


N11

N9

N8

N5

Bla

N6

BLr

Bla

dh

Ha
V1
Y1

Y2

N1

Vt
N2

Vo

D
N4

0.10

st= 0.002

L=

Caractersticas del Canal Alimentador


Caudal (m3/s)
Qa =
Ancho de Base (m)
ba =
Talud
Z =
Pendiente (m/m)
Sa =
Rugosidad
n =
Altura de agua (m)
Y1 =
Velocidad (m/s)
V1 =
Carga de velocidad (m) :V1^2/2*g hv1 =
Altura de Canal (m) Ha =
1.3 ~

N7

N3

10.00

Lt =

2.00

Canal de Derivacin
5.000
1.400
1.000

Caudal (m3/s)
Ancho de Base (m)
Talud
Pendiente (m/m)
Rugosidad
Altura de agua (m)
Velocidad (m/s)
Carga de velocidad (m)
Altura de Canal (m)

0.0020

0.014
0.97
2.16
0.11
1.60

Qa =
ba =
Z =
Sd =
n =
Y2 =
V2 =
hv2 =
Hd =

1.000
1.000
0.000
0.0020

0.014
0.71
1.41
0.07
0.95

Sabemos que la velocidad en el conducto de la estructura de toma debe ser similar a la del canal derivado,
es decir, Vt = Vd; por lo tanto :
A (m2) : Qa / V2

0.709

Luego se har un tanteo para escoger la compuerta que se ajuste a una seccin cuadrada o tubera de tal
manera que nos permita pasar el caudal sin prdidas apreciables.
Probaremos con una compuerta deslizante Tipo ARMCO Modelo 5.00 de :
y un tubo de dimetro D =
12 pulgadas =
0.305 m
Area del Tubo (m2) : * D^2 / 4

At =

0.073

Velocidad en el tubo (m/s) : Qd / At

Vt =

13.7

>

1.410

12

12

pulgadas

OK !

Nota : En el caso que la velocidad Vt > Vd, se aumentar el dimetro hasta que : Vt ~ Vd
Como esta velocidad " Vt " es similar a la del canal derivado, podemos pasar a calcular las prdidas de carga :
dh (m) : (Vt^2 / 19.62) * [1 + (0.78 / Cc^2) + f * (L / D)]

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


Coeficiente de Contraccin en la Tubera : Cc =
0.644 (valor normal, cuando la toma es perpendicular al canal)
Factor de friccin
f =
0.0190 (en el cuadro, con D
12 " y
Vt =
13.7
Reemplazando valores en la frmula, se tiene :

Asumimos :

dh =
dh =

33.52
35

(prdida de carga en la toma)

El valor de " dh ", se aproxima por encima ya que de haber aproximado dh =


garanta de que va a pasar el caudal necesario; en tanto que aproximando a :
y podr controlarse con la compuerta

33.52 m, no tendramos
35 m, el caudal aumentar

Determinada la prdida de carga en la toma (dh), pasaremos a esquematizarla.


Cota de Rasante de fondo de Canal Alimentador " N1 ", en (msnm)
Supongamos un valor de :

N1 =

338.07

Nivel d' Agua Canal Alimentador:N1+Y1

N5 =

339.044

Cota de Rasante de fondo de Canal Derivado " N4 ", en (msnm)


N7 = N5 - dh - Y2

N7 =

303.335

Con el fin de obtener una medicin del caudal bastante aproximada, la sumergencia " S " debe ser igual al
dimetro del conducto, es decir : S = D; por lo tanto se tiene que la :
Cota de Captacin : N5 - 2 * D

N3 =

338.434

Se asume un valor de 0.10 m, por el empotramiento de la compuerta


Cota del escaln : N3 - 0.10

N2 =

338.33

Nivel d' Agua Canal Derivado : N1 - dh

N6 =

303.07

Cota:salida del conducto : N3 - L * St

N4 =

338.414

Altura del Relleno (m)


Altura del canal alimentador (m)

BLr =
Ha =

0.20
1.6

Nivel de subrasante (msnm)

N8 =

339.87

Bordo libre de afirmado (m)

Bla =

0.20

Nivel de Carretera C. Alimen. (msnm)

N9 =

340.07

N8 = N1 + BLr + Ha

N9 = N8 + Bla

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


N10 = N7 + Hd + Blr
Altura del canal derivado (m)
Bordo libre de afirmado (m)

Hd =
BLr =

1
0.20

Nivel de Carretera C. Derivado (msnm)

N10 =

304.54

N11 = N3 + (D / 2) + H
Valor obtenido del manual Compuertas de Control Tipo ARMCO; para compuertas Modelo 5.00 y
Tamao d' Abertura:
12 x 12
pulgadas, se tiene
H=
4 a 8
pies
tomaremos : H =

5.5 pies
H=

1.68

Nivel superior de la pantalla de concreto (N11) donde se empotra la compuerta


N11 =

340.27

>

N9 =

340.07

OK !

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES

ALES
Pg 1

N10

Hd

V2
N7

1.00

Valores de " f " para Tuberas Lisas y Limpias de Hierro Colado, de Acero y de Concreto
Dimetro
pulgadas

rdidas de carga :

(Pulg)

(m)

0.30
f

4
5
6
8
10
12
14
16
18
20
24
30

0.10
0.13
0.15
0.20
0.25
0.30
0.36
0.41
0.46
0.51
0.61
0.76

0.0285
0.0275
0.0265
0.0255
0.0245
0.0235
0.0233
0.0228
0.0220
0.0215
0.0210
0.0200

0.61

0.91

0.0255
0.0245
0.0240
0.0230
0.0220
0.0215
0.0210
0.0205
0.0200
0.0195
0.0190
0.0185

0.0240
0.0230
0.0225
0.0215
0.0205
0.0200
0.0197
0.0194
0.0190
0.0185
0.0180
0.0175

Velocidad ( Vt ) en m/s
1.22
1.52
1.83
2.44
0.0230
0.0225
0.0215
0.0205
0.0200
0.0190
0.0188
0.0185
0.0180
0.0175
0.0170
0.0165

0.0225
0.0215
0.0210
0.0200
0.0190
0.0185
0.0183
0.0180
0.0175
0.0170
0.0165
0.0160

0.0220
0.0210
0.0200
0.0195
0.0185
0.0180
0.0178
0.0175
0.0170
0.0165
0.0160
0.0155

0.0210
0.0200
0.0195
0.0185
0.0180
0.0175
0.0170
0.0167
0.0165
0.0160
0.0155
0.0150

3.05
0.0200
0.0195
0.0190
0.0180
0.0175
0.0170
0.0165
0.0162
0.0160
0.0155
0.0150
0.0145

ALES

pendicular al canal)

m/s)

Pg 2

caudal aumentar

36
42
48
60
72
84
96

0.91
1.07
1.22
1.52
1.83
2.13
2.44

0.0195
0.0190
0.0185
0.0180
0.0175
0.0170
0.0165

0.0180
0.0175
0.0170
0.0165
0.0160
0.0155
0.0150

0.0170
0.0165
0.0160
0.0155
0.0150
0.0145
0.0140

0.0160
0.0155
0.0155
0.0150
0.0145
0.0140
0.0135

0.0155
0.0150
0.0150
0.0145
0.0140
0.0135
0.0130

0.0150
0.0145
0.0145
0.0140
0.0135
0.0130
0.0125

0.0145
0.0140
0.0140
0.0135
0.0130
0.0125
0.0120

Fuente : " Hidrulica " , de George E. Russell, pg. 231, sexta edicin 1976

0.0140
0.0135
0.0135
0.0130
0.0125
0.0120
0.0120

ALES

Pg 3

ALES

Lisas y Limpias de Hierro Colado, de Acero y de Concreto


Velocidad ( Vt ) en m/s
4.57

6.10

0.0190
0.0185
0.0175
0.0170
0.0165
0.0160
0.0155
0.0152
0.0150
0.0145
0.0140
0.0135

0.0180
0.0175
0.0170
0.0160
0.0155
0.0150
0.0148
0.0145
0.0140
0.0140
0.0135
0.0130

0.0130
0.0130
0.0125
0.0120
0.0120
0.0115
0.0110

0.0125
0.0125
0.0120
0.0115
0.0115
0.0110
0.0105

CALCULO HIDRAULICO : TOMAS DE PARCELAS


N5
N4

N6
H
Ha

V1
Y1

N2

N1

Vo

N3
D

Vt
Terreno de Cultivo

0.10

St = 0.02
L = 3.00

Caractersticas del Canal Alimentador


Caudal (m3/s)
Ancho de Base (m)
Talud
Pendiente (m/m)
Rugosidad
Altura de agua (m)
Velocidad (m/s)
Carga de velocidad (m) :V1^2/2*g
Altura de Canal (m)
Ha =

Canal de Derivacin
Qa =
ba =
Z =
Sa =
n =
Y1 =
V1 =
hv1 =
0.84 ~

0.625
0.400
1.500

Caudal (m3/s)

Qa =

0.050

0.0005

0.014
0.63
0.74
0.04
0.85

Sabemos que la velocidad en el conducto de la estructura de toma debe ser similar a la del Caudal derivado,
es decir, Vt = Vd; por lo tanto :
Asumiendo una velocidad en el tubo Vt =
At (m2) : Qa / V2

0.80 m/s, entonces, el rea en el tubo es :


At =

0.781 valor muy alto, por lo que haremos unos reclculos :

Luego se har un tanteo para escoger la compuerta que se ajuste a una seccin cuadrada o tubera de tal
manera que nos permita pasar el caudal sin prdidas apreciables.
Probaremos con una compuerta deslizante Tipo ARMCO Modelo 5.00 de :
y un tubo de dimetro D =
14 pulgadas =
0.356 m
Area del Tubo (m2) : * D^2 / 4

At =

0.100

Velocidad en el tubo (m/s) : Qd / At

Vt =

0.50

<

V1 =

14

0.74

14

pulgadas

OK !

Nota : En el caso que la velocidad Vt > Vd, se aumentar el dimetro hasta que : Vt ~ Vd
Como esta velocidad " Vt " es similar a la del canal derivado, podemos pasar a calcular las prdidas de carga :
a) Prdidas por Friccin (hf)

CALCULO HIDRAULICO : TOMAS DE PARCELAS


hf (m) : f * (L / D) * Vt^2 / 19.62
Factor de friccin

f =

0.0218 (en el cuadro con D=

14 " y

Vt =

0.50

Reemplazando valores en la frmula, se tiene :


hf =

0.0023

b) Prdidas por Entrada (he)


he (m) : Ke * Vt^2 / 19.62
En la cual " Ke " es un coeficiente que depende del grado de abocinamiento de la entrada, a tal efecto, en
nuestro caso trabajaremos con Ke =
0.50
reemplazando :

he =

0.0064

Hf =

0.01

c) Prdida de Carga Total (Hf)


Hf (m) : hf + he

Determinada la prdida de carga en la toma (Hf), pasaremos a esquematizarla.


Cota de Rasante de fondo de Canal Alimentador " N1 ", en (msnm)
Supongamos un valor de :

N1 =

99.669

Nivel d' Agua Canal Alimentador:N1+Y1

N4 =

100.299

Se asume un valor de 0.10 m, por el empotramiento de la compuerta


Cota del escaln : N1 + 0.10

N2 =

99.769

Cota:salida del conducto : N2 - L * St

N3 =

99.709

Nivel d' Agua en la Salida : N3 + D - He

N6 =

100.055

N5 = N2 + (D / 2) + H
Valor obtenido del manual Compuertas de Control Tipo ARMCO; para compuertas Modelo 5.00 y
Tamao d' Abertura:
0 x Qa = pulgadas, se tiene
H=
4 a 8
pies
tomaremos : H =

4 pies

H=
N5 =

1.22
101.167

CALCULO HIDRAULICO : TOMAS DE PARCELAS

Pg. 1

Terreno de Cultivo

Valores de " f " para Tuberas Lisas y Limpias de Hierro Colado, de Acero y de Concreto
Dimetro

s unos reclculos :

pulgadas

rdidas de carga :

(Pulg)

(m)

4
5
6
8
10
12
14
16
18
20
24
30
36
42
48
60
72
84
96

0.10
0.13
0.15
0.20
0.25
0.30
0.36
0.41
0.46
0.51
0.61
0.76
0.91
1.07
1.22
1.52
1.83
2.13
2.44

0.30

0.61

0.91

0.0285
0.0275
0.0265
0.0255
0.0245
0.0235
0.0233
0.0228
0.0220
0.0215
0.0210
0.0200
0.0195
0.0190
0.0185
0.0180
0.0175
0.0170
0.0165

0.0255
0.0245
0.0240
0.0230
0.0220
0.0215
0.0210
0.0205
0.0200
0.0195
0.0190
0.0185
0.0180
0.0175
0.0170
0.0165
0.0160
0.0155
0.0150

0.0240
0.0230
0.0225
0.0215
0.0205
0.0200
0.0197
0.0194
0.0190
0.0185
0.0180
0.0175
0.0170
0.0165
0.0160
0.0155
0.0150
0.0145
0.0140

Velocidad ( Vt ) en m/s
1.22
1.52
1.83
2.44
f
0.0230
0.0225
0.0215
0.0205
0.0200
0.0190
0.0188
0.0185
0.0180
0.0175
0.0170
0.0165
0.0160
0.0155
0.0155
0.0150
0.0145
0.0140
0.0135

0.0225
0.0215
0.0210
0.0200
0.0190
0.0185
0.0183
0.0180
0.0175
0.0170
0.0165
0.0160
0.0155
0.0150
0.0150
0.0145
0.0140
0.0135
0.0130

0.0220
0.0210
0.0200
0.0195
0.0185
0.0180
0.0178
0.0175
0.0170
0.0165
0.0160
0.0155
0.0150
0.0145
0.0145
0.0140
0.0135
0.0130
0.0125

0.0210
0.0200
0.0195
0.0185
0.0180
0.0175
0.0170
0.0167
0.0165
0.0160
0.0155
0.0150
0.0145
0.0140
0.0140
0.0135
0.0130
0.0125
0.0120

Fuente : " Hidrulica " , de George E. Russell, pg. 231, sexta edicin 1976
V

0.30
0.61
-0.31
0.20
X=

0.0233
0.0210
0.0023
X
-0.0015

3.05
0.0200
0.0195
0.0190
0.0180
0.0175
0.0170
0.0165
0.0162
0.0160
0.0155
0.0150
0.0145
0.0140
0.0135
0.0135
0.0130
0.0125
0.0120
0.0120

f = 0.0218
m/s)

Pg. 2

Lisas y Limpias de Hierro Colado, de Acero y de Concreto


Velocidad ( Vt ) en m/s
4.57

6.10

0.0190
0.0185
0.0175
0.0170
0.0165
0.0160
0.0155
0.0152
0.0150
0.0145
0.0140
0.0135
0.0130
0.0130
0.0125
0.0120
0.0120
0.0115
0.0110

0.0180
0.0175
0.0170
0.0160
0.0155
0.0150
0.0148
0.0145
0.0140
0.0140
0.0135
0.0130
0.0125
0.0125
0.0120
0.0115
0.0115
0.0110
0.0105

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


N11

N9

N8

N5

Ha
V1
Y1
N1

Vt
N2

Vo

N3
0.10

st= 0.002

L=

Caractersticas del Canal Alimentador


Caudal (m3/s)
Qa =
Ancho de Base (m)
ba =
Talud
Z =
Pendiente (m/m)
Sa =
Rugosidad
n =
Altura de agua (m)
Y1 =
Velocidad (m/s)
V1 =
Carga de velocidad (m) :V1^2/2*g hv1 =
Altura de Canal (m) Ha =
1.3 ~

4.00

Canal de Derivacin
5.000
1.400
1.000

Caudal (m3/s)
Ancho de Base (m)
Talud
Pendiente (m/m)
Rugosidad
Altura de agua (m)
Velocidad (m/s)
Carga de velocidad (m)
Altura de Canal (m)

0.0020

0.014
0.97
2.16
0.11
1.6

Sabemos que la velocidad en el conducto de la estructura de toma debe ser similar a la del canal derivado,
es decir, Vt = Vd; por lo tanto :
A (m2) : Qa / V2

0.709

Luego se har un tanteo para escoger la compuerta que se ajuste a una seccin cuadrada o tubera de tal
manera que nos permita pasar el caudal sin prdidas apreciables.
Probaremos con una compuerta deslizante Tipo ARMCO Modelo 5.00 de :
y un tubo de dimetro D =
36 pulgadas =
0.914 m
Area del Tubo (m2) : * D^2 / 4

At =

0.66

Velocidad en el tubo (m/s) : Qd / At

Vt =

1.52

>

36

1.41

Nota : En el caso que la velocidad Vt > Vd, se aumentar el dimetro hasta que : Vt ~ Vd
Como esta velocidad " Vt " es similar a la del canal derivado, podemos pasar a calcular las prdidas de carga :
dh (m) : (Vt^2 / 19.62) * [1 + (0.78 / Cc^2) + f * (L / D)]

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


Coeficiente de Contraccin en la Tubera : Cc =
Factor de friccin
f =

0.644 (valor normal, cuando la toma es perpendicular al canal)


0.0155 (en el cuadro, con D
36

Reemplazando valores en la frmula, se tiene :

Asumimos :

dh =
dh =

0.347
0.4

(prdida de carga en la toma)

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


El valor de " dh ", se aproxima por encima ya que de haber aproximado dh =
garanta de que va a pasar el caudal necesario; en tanto que aproximando a :
y podr controlarse con la compuerta

0.35
0.4

Determinada la prdida de carga en la toma (dh), pasaremos a esquematizarla.


Cota de Rasante de fondo de Canal Alimentador " N1 ", en (msnm)
Supongamos un valor de :

N1 =

99.669

Nivel d' Agua Canal Alimentador:N1+Y1

N5 =

100.643

Cota de Rasante de fondo de Canal Derivado " N4 ", en (msnm)


N7 = N5 - dh - Y2

N7 =

99.534

Con el fin de obtener una medicin del caudal bastante aproximada, la sumergencia " S " debe ser igual al
dimetro del conducto, es decir : S = D; por lo tanto se tiene que la :
Cota de Captacin : N5 - 2 * D

N3 =

98.815

Se asume un valor de 0.10 m, por el empotramiento de la compuerta


Cota del escaln : N3 - 0.10

N2 =

98.715

Nivel d' Agua Canal Derivado : N1 - dh

N6 =

99.269

Cota:salida del conducto : N3 - L * St

N4 =

98.807

Altura del Relleno (m)


Altura del canal alimentador (m)

BLr =
Ha =

0.20
1.6

Nivel de subrasante (msnm)

N8 =

101.469

Bordo libre de afirmado (m)

Bla =

0.20

Nivel de Carretera C. Alimen. (msnm)

N9 =

101.669

Altura del canal derivado (m)


Bordo libre de afirmado (m)

Hd =
BLr =

1
0.20

Nivel de Carretera C. Derivado (msnm)

N10 = 100.734

N8 = N1 + BLr + Ha

N9 = N8 + Bla

N10 = N7 + Hd + Blr

CALCULO HIDRAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


N11 = N3 + (D / 2) + H
Valor obtenido del manual Compuertas de Control Tipo ARMCO; para compuertas Modelo 5.00 y
Tamao d' Abertura:
36 x 36
pulgadas, se tiene
H=
4 a
tomaremos : H =

8 pies
H=

2.44

Nivel superior de la pantalla de concreto (N11) donde se empotra la compuerta


N11 = 101.712

>

N9 =

101.669

RAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


Pg 1

N10

Bla

N6

BLr

Bla

dh
Hd

Y2

V2
N7

N4

Lt = 0.00

Qa =
ba =
Z =
Sd =
n =
Y2 =
V2 =
hv2 =
Hd =

1.000
1.000
0.000
0.0020

0.014
0.71
1.41
0.07
0.95

e la estructura de toma debe ser similar a la del canal derivado,

mpuerta que se ajuste a una seccin cuadrada o tubera de tal

OK !
se aumentar el dimetro hasta que : Vt ~ Vd

l canal derivado, podemos pasar a calcular las prdidas de carga :

36

pulgadas

RAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


(valor normal, cuando la toma es perpendicular al canal)

" y

(prdida de carga en la toma)

Vt =

1.52 m/s)

RAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES


Pg 2

m, no tendramos
m, el caudal aumentar

984015045 lito quispe

al bastante aproximada, la sumergencia " S " debe ser igual al

RAULICO : TOMAS CON MEDICION DE CAUDAL EN CANALES

ontrol Tipo ARMCO; para compuertas Modelo 5.00 y


8

pies

OK !

Вам также может понравиться