Академический Документы
Профессиональный Документы
Культура Документы
FKE...4
DATA SHEET
The FCXA2 level transmitter accurately measures liquid level
and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon
sensor with state-of-the-art microprocessor technology to
provide exceptional performance and functionality.
FEATURES
1. High accuracy
0.2% accuracy for all calibrated spans is a standard feature for all models covering 0.32kPa{3.2mbar} range to
500kPa{5bar} high differential pressure range. 0.1% accuracy is available as option. Fuji's micro-capacitance
silicon sensor assures this accuracy for all elevated or
suppressed calibration ranges without additional adjustment.
2. Minimum environmental influence
The "Advanced Floating Cell" design which protects the
pressure sensor against changes in temperature, static
pressure, and overpressure substantially reduces total
measurement error in actual field applications.
3. Fuji/HART bilingual communications protocol and
FOUNDATION fieldbus and Profibus compatibility
FCXA2 series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART.
Any HART compatible devices can communicate with
FCXA2.
Further, by upgrading electronics FOUNDATION
fieldbus and Profibus are also available.
4. Application flexibility
Various options that render the FCXA2 suitable for
almost any process applications include:
Analog indicator at either the electronics side or terminal side
Full range of hazardous area approvals
Built-in RFI filter and lightning arrester
5-digit LCD meter with engineering unit
Stainless steel electronics housing
Wide selection of materials
High temperature, high vacuum service.
5. Programmable output Linearization Function
Output signal can be freely programmable.
(Up to 14 compensated points at approximation.)
6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,
Over Scale: 20.8 to 21.6mA)
Burnout signal level is adjustable using Model FXW Hand
Held Communicator (HHC) to comply with NAMUR NE43.
7. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as
wet calibration.
SPECIFICATIONS
Functional specifications
Service:
Liquid, gas, or vapour
Static pressure, span, and range limit:
Type
F KE
F KE
F KE
Static
pressure
0.32
{3.2}
1.3
{13}
5
{50}
Up to
flange
rating
Min.
Max.
32
{320}
130
{1300}
500
{5000}
Range limit
[kPa] {m bar}
+/
{ +/
+/
{ +/
+/
{ +/
32
320}
130
1300}
500
5000}
EDSX7-60f
Date
Apr. 1, 2003
FKE...4
Load limitations: see figure below
[]
Load resistance
2000
1533
1500
1000
600
Operating
area
500
24V
250
10
45V
16.1
10.5V
Power voltage
50
[V]
Note: For communication with HHC(1) (Model: FXW), min. of 250 required.
ATEX
Factory
Mutual
CSA
TIIS
Flameproof
Intrinsic safety
Ex II 2 GD
- EExd IIC T5/T6
Class I II III
Div. 1
Groups B thru. G
Class I II III
Div. 1
Groups C thru. G
Ex do IIB+H2 T4
Ex II 1 GD
- EExia IIC T4/T5
Class I II III
Div. 1
Groups A thru. F
Class I II III
Div. 1
Groups A thru. G
Ex ia IIC T4 (*)
Type n
Nonincendive
Ex II 3 GD
- EExn IIC T4/T5
Class I II III
Div. 2
Groups A thru. G
Class I II III
Div. 2
Groups A thru. G
Zero/span adjustment:
Zero and span are adjustable from the
HHC(1). Zero and span are also adjustable
externally from the adjustment screw
(Span adjustment is not available with 9th
digit code "L, P, Q, S").
Damping:
Adjustable from HHC or local adjustment
unit with LCD display.
The time constant is adjustable between
0.12 to 32 seconds.
Zero elevation/suppression:
100% to + 100% of URL
Normal/reverse action:
Selectable from HHC(1)
Indication:
Analog indicator or 5-digit LCD meter, as
specified.
Burnout direction: Selectable from HHC(1)
If self-diagnostic detect transmitter failure, the analog signal will be driven to either Output Hold, Output Overscale
or Output Underscale modes.
Output Hold:
Output signal is hold as the value just before failure happens.
Output Overscale:
Adjustable within the range 20.8mA to
21.6mA from HHC(1)
Output Underscale:
Adjustable within the range 3.2mA to
3.8mA from HHC(1)
3.2
3.8 4
20 20.8
Fluorinated oil
W, A and D
20 to 120C
Silicone oil
15 to 250C
40 to 120C
15 to 250C
85 to 300C
2.7kPa abs
{20.3mmHg abs}
0.13kPa abs
{0.98mmHg abs}
Low pressure side contact liquid temperature on transmitter of
Code H, J, S, T is 120C or lower. Low pressure side contact liquid
temperature of Code K is 85C or lower
K
15 to 150C
Storage: 40 to + 90C
Humidity limit: 0 to 100% RH
Communication: With HHC(1) (Model FXW, consult Data
Sheet No. EDS8-47), following information can be remotely displayed or reconfigured.
Note: HHC's version must be more than
6.0 (or FXW
1 3), for FCXA2.
Items
Display
Set
Tag No.
Model No.
Serial No.
Engineering unit
Range limit
Measuring range
Damping
Output mode
Burnout direction
Calibration
Output adjust
Data
Self diagnoses
Printer
Transmitter display
Linearize
Rerange
21.6 [mA]
Atmospheric
pressure
85 to 300C
Y and G
Over scale
Burnout
Normal operating range
Under scale
Probable under range
Burnout
Lower limit
of
static press
Process
temperature
Hazardous locations:
Authorities
Loop-check output:
Transmitter can be configured to provide
constant signal 3.8mA through 21.6mA
by HHC (1).
Temperature limit:
Ambient: 40 to + 85C
( 20 to + 80C for LCD indicator)
( 40 to + 60C for arrester option)
( 10 to + 60C for fluorinated oil fill transmitter)
For explosionproof units (flameproof or intrinsic safety),
ambient temperature must be within the limits specified in each standard.
Process:
Performance specifications
Physical specifications
Range code
*)
Time constant *)
"3"
0.55 s
0.3 s
Dead time *)
0.2 s
Electrical connections:
G 1/2, 1/2-14 NPT, Pg13.5, or M20 x 1.5
conduit, as specified.
And 1-conduit or 2-conduit, as specified.
Process connections:
LP side: 1/4-18 NPT or Rc1/4.
HP side: ANSI, DIN, or JIS raised face
flange. See OUTLINE DIAGRAM for detailed dimensions.
Refer to "Code symbols"
Process-wetted parts material:
LP side
HP side
Material
code
Wetted
Diaphragm &
Process
(7th digit
Diaphragm
sensor body
flange face
cover
in "Code
symbols")
316 stainless 316L stainless 316 stainless 316L stainless
V
316 stainless 316L stainless 316 stainless 316L stainless
J
steel
+Au coating
316 stainless 316L stainless 316 stainless Hastelloy-C
C
316 stainless 316L stainless 316 stainless Monel
D
316 stainless 316L stainless 316 stainless Tantalum
E
Hastelloy-C
316 stainless Hastelloy-C
Hastelloy-C
H
lining
Monel lining Monel
M
316 stainless Monel
Tantalum
T
316 stainless Tantalum
Tantalum
lining
Hastelloy-C
Hastelloy-C Hastelloy-C
Hastelloy-C
B
lining
Monel lining Monel
L
Monel lining Monel
Tantalum
U
Tantalum
Hastelloy-C
Tantalum
lining
P
316 stainless 316L stainless 316 stainless Tantalum
316 stainless 316L stainless 316 stainless Zirconium
R
Optional features
Indicator:
FKE...4
Local adjustment unit with LCD display:
An optional 5-digit LCD meter with Zero/
Span adjustment function, loop-check
function and damping adjustment function, is available.
Arrester:
A built-in arrester protects the electronics from lightning surges.
Lightning surge immunity:
4kV (1.2 50s)
Oxygen service: Special cleaning procedures are followed
throughout the process to maintain all
process wetted parts oil-free.
The fill fluid is fluorinated oil.
Chlorine service: Oil-free procedures as above. Includes
fluorinated oil for fill.
Degreasing:
Process-wetted parts are cleaned, but the
fill fluid is standard silicone oil. Not for
use on oxygen or chlorine measurement.
Vacuum service: Special silicone oil and filling procedure
are applied. See Fig.1 and Fig.2
Optional tag plate:
An extra stainless steel tag with customer
tag data is wired to the transmitter.
Silicone (Code S)
Silicone (Code T)
Operating pressure
101
{1010}
53.3
{533}
Operating area
13.3
{133}
ACCESSORIES
Oval flanges:
ORDERING INFORMATION
2.7
{27}
40 15
Fig. 1
60 85 120
Process temperature[C ]
[kPa abs]
{mbar abs}
Sealing liquid:Silicone (Code K)
300
are :
EMI (Emission)
EN61326 : 1997
Class A (standard for Industrial Location)
Frequency range
MHz
Limits
Reference
standard
30 to 230
CISPR16-1 and
CISPR16-2
230 to 1000
EMI (Immunity)
101
{1010}
EN61326: 1997
Annex A (standard for Industrial Location)
Basic
standard
Performance
criteria
IEC61000-4-2
80 to 1000MHz
Electromagnetic
10V/m
field
80%AM (1kHz)
IEC61000-4-3
Rated power
frequency
magnetic field
30A/m
50Hz
IEC61000-4-8
Burst
2kV
5kHz
IEC61000-4-4
Surge
1.2s/50s
1kV (Line to line)
2kV (Line to ground)
IEC61000-4-5
Conducted RF
0.15 to 80MHz
3V
80%AM (1kHz)
IEC61000-4-6
Phenomenon
Operating pressure
Electrostatic
discharge
Operating area
Non-operating area
0.13
{1.3}
15
150
Process temperature[C ]
Fig. 2
[kPa abs]
{mbar abs}
Coating of cell:
Test value
4kV (Contact)
8kV (Air)
CODE SYMBOLS
1 2 3 4 5 6 7 8
Digit
4
Description
<Connections>
Process
connection
Rc1/4
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/4-18NPT
Rc1/4
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/4-18NPT
Oval flange
screw
7/16-20UNF
7/16-20UNF
M10
M10
7/16-20UNF
7/16-20UNF
7/16-20UNF
M10
M10
7/16-20UNF
Conduit
connection
G 1/2
(1)
1/2-14NPT (1)
Pg13.5
(1)
M201.5 (1)
Pg13.5
(1)
G 1/2
(2)
1/2-14NPT (2)
Pg13.5
(2)
M201.5 (2)
Pg13.5
(2)
Note
Hastelloy-C lining
Hastelloy-C
Monel lining
Monel
Tantalum lining
Tantalum
Hastelloy-C lining
Hastelloy-C
Monel lining
Monel
Tantalum lining
Tantalum
316L stainless steel 316 stainless steel
316L stainless steel 316 stainless steel
9 10 11 12 13
14 15
21
Digit No.
of code
A
B
C
D
E
S
T
V
W
X
<Mounting flange>
Material
Size and rating
304 stainless
JIS 10K 80A
steel
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN40 DN80
DIN PN16 DN100
JIS 20K 80A
ANSI/JPI 600LB 3B
Carbon steel
JIS 10K 80A
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN40 DN80
DIN PN16 DN100
316 stainless
JIS 10K 80A
steel
ANSI/JPI 150LB 3B
ANSI/JPI 150LB 4B
ANSI/JPI 300LB 3B
ANSI/JPI 300LB 4B
ANSI/JPI 600LB 3B
<Span limit (*1) [kPa] {m bar}>
0.32
32
{3.2
320}
1.3
130
{13
1300}
5
500
{50
5000}
<Material>
LP side
Wetted sensor
Diaphragm
Process cover
body
316 stainless steel 316L stainless steel 316 stainless steel
316 stainless steel 316L stainless steel 316 stainless steel
316 stainless steel 316L stainless steel 316 stainless steel
316 stainless steel 316L stainless steel 316 stainless steel
316 stainless steel 316L stainless steel 316 stainless steel
F KE
Note 1
0
1
2
3
4
5
6
7
8
9
M
R
A
B
C
D
E
F
G
H
J
K
S
T
U
V
W
X
3
5
6
HP side
Diaphragm and
flange face
316L stainless steel
Hastelloy-C
Monel
Tantalum
Diaphram:
316L stainless steel
+Au coating
Flange:
316 stainless steel
Hastelloy-C
Monel
Tantalum
Hastelloy-C
Monel
Tantalum
Titanium
Note 3
Zirconium
Note 2, 3
V
C
D
E
J
H
M
T
B
L
U
P
R
Note 1: (*1) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance.
Note 2: (*2) Material Code R; 6th digit code "6" is not available.
Note 3: (*3) 5th digit code "0, 2, 4, 6, 8, A, C, E, G, J" are available.
FKE...4
1 2 3 4 5 6 7 8
Digit
Description
Note
<Indicator and arrester>
9
Indicator
Arrester
None
None
Z/S board
Analog, 0 to 100% linear scale
None
attached.
Analog, custom scale
None
Approval pending
None
Yes
for 10th digit code
Analog, 0 to 100% linear scale
Yes
"G, H, J, K, P"
Analog, custom scale
Yes
Digital, 0 to 100%
None
Digital, custom scale
None
Digital, 0 to 100%
Yes
Digital, custom scale
Yes
Digital, 0 to 100%
(Local adjustment unit with LCD display)
None
Digital, custom scale
(Local adjustment unit with LCD display)
None
Digital, 0 to 100% square root
Approval pending
(Local adjustment unit with LCD display)
None for 10th digit code
Digital, 0 to 100%
"D, E, G, H, J, K, P"
(Local adjustment unit with LCD display)
Yes
Digital, custom scale
(Local adjustment unit with LCD display)
Yes
Digital, 0 to 100% square root
(Local adjustment unit with LCD display)
Yes
<Approvals for hazardous locations>
10
None (for ordinary locations)
TIIS, Flameproof (Conduit seal)
(Available for 4th digit code A, S)
TIIS, Flameproof (Cable gland seal) (Available for 4th digit code A, S)
FM, Flameproof (or explosionproof) (Available for 4th digit code B, T)
CSA, Flameproof (or explosionproof) (Available for 4th digit code B, T)
ATEX, Flameproof
TIIS, Intrinsic safety (Approval pending)
FM, Intrinsic safety and nonincendive
CSA, Intrinsic safety and nonincendive
ATEX, Intrinsic safety
ATEX, Type n
<Diaphragm extension [mm]>
11
Extension [mm]
Applicable material code
0
Any
50
100
(7th digit code "V" only)
150
200
50
100
(7th digit code "H" ,"B" ,"C" only)
150
200
<Options>
12
Extra SS tag plate
Stainless steel elec. housing
Coating of cell
None
None
None
Yes
None
None
None
Yes
None
Note 4
Yes
(* 4)
Yes
None
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
13
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Oxygen service
Fluorinated oil (7th digit code "V", "J" only)
Chlorine service
Fluorinated oil (7th digit code "H", "T", "B", "U", "C" and "E")
High temp. 250C
7th digit code "V", "C", "H", "B"
High temp. 300C
High temp. and vacuum (250C)
(* 5) Note 5
7th digit code "V"
High temp. and vacuum (300C)
High temp. and high vacuum Silicone oil
<O-ring, gasket and Teflon membrane>
14
O-ring /Gasket
Teflon membrane
Viton (O-ring)
None
Teflon (gasket)
None
Viton (O-ring)
Yes (5th digit code "0", "2", "4", "6", "8", "A", "C", "E",
Teflon (gasket)
Yes "G", "J", "M", "R", "S", "T", "V", "X" and 11th
digit code "Y" are available.
13th digit code "H, J, S, T, K" are not available.)
F KE
9 10 11 12 13
14 15
21
A
B
D
E
F
H
L
P
Q
S
1
2
3
4
5
6
A
B
C
D
E
X
G
H
J
K
P
Y
A
B
C
D
E
F
G
H
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
H
J
S
T
K
A
B
C
D
Note 4: (*4) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select "Yes"
Note 5: (*5) Treatment; None
Digit No.
of code
1 2 3 4 5 6 7 8
Digit
15
21
Description
<Bolt/nut> (* 6)
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut
Cr-Mo alloy hexagon bolt/nut
304 stainless steel bolt /304 stainless steel nut
<Other options>
High accuracy type
Low temperature effect type
H+J
Note
Note 6
F KE
9 10 11 12 13
14 15
21
Digit No.
of code
A
B
E
H
J
K
Note 6: (*6) In case of tropical use, select stainless bolts and nuts.
FKE...4
Flange : ANSI/JPI
-150LB-3B
Zero ADJ.screw
Fastener
(Flameproof only)
(10)
N holes
h dia
52.5
105
80
Up
80
88
Down
L2
Note 1)
(27)
L1
Vent / drain plug
t
41.3
Inner of gasket
Detail "A"
(L.P conn.)
18.5
H.P. conn.
Sensor unit
Electronics unit
185
150
126
100
73
38
8-19
JIS-10K-80A
210
175
151
103
96
38
8-19
JIS-10K-100A
200
160
126
100
73
42
8-23
JIS-20K-80A
210
170
126
100
73
48
8-23
JIS-30K-80A
240
195
151
103
96
52
8-25
JIS-30K-100A
191
152.5
126
100
73
44
4-20
ANSI/JPI-150LB-3B
229
190.5
151
103
96
44
N-h
8-20
See table 1
11th degit
code
Earth terminal
(Flange)
ANSI/JPI-150LB-4B
9.5
~ 13
A
E
50
10
~ 17
B
F
100
10.5 ~ 17.5
C
G
150
11
D
H
200
11.5 ~ 18.5
Press.conn.
J
A, S
17 8
Rc1/4
B, T
1/2-14NPT
16 5
1/4-18NPT
Pg13.5
1/4-18NPT
210
168
126
100
73
49
8-23
ANSI/JPI-300LB-3B
C, V
254
200
151
103
96
52
8-23
ANSI/JPI-300LB-4B
D, W
M20 1.5
16 5
1/4-18NPT
210
168
126
100
73
52
8-23
ANSI/JPI-600LB-3B
200
160
126
100
73
44
8-18
DIN
PN40
DN80
E, X
Pg13.5
1/4-18NPT
220
180
151
103
96
40
8-18
DIN
PN16
DN100
4.5
4.5
Table 1
CONNECTION DIAGRAM
CK CK
(M4 screws)
L1
L2
L3
323
150
286
317
144
290
~ 18
G1/2
Mass apprpx.
(kg)
L (mm)
Conduit conn.
K
M N
G1/2
See table 1
L3
13
15
43
46.4
D
E
F
143
27
2.5
Detail "C"
Detail "B"
(Conduit conn.)
17
20
M N
Cable gland
(option)
Screw depth15
7/16-20UNF
Screw depth15
M10
Screw depth15
M10
Screw depth15
7/16-20UNF
Screw depth15
Fastener
(Flameproof only)
Zero ADJ.screw
N holes
h dia
105
52.5
107
80
Up
80
(10)
Flange : ANSI/JPI
-150LB-3B
88
Down
L2
Note 1)
(27)
L1
Vent / drain plug
L
Cable gland
(option)
20
Detail "B"
(L.P conn.)
Detail "A"
(L.P. conn.)
4th digit code "S"
Earth terminal
Inner of gasket
16
40.5
16
10
2 -0.1
186
43
46.4
D
E
F
1/4-18NPT
+0.2
12 +0.1
4
L3
Detail "C"
(Conduit conn.)
H.P. conn.
L (mm)
Mass apprpx.
(kg)
11.5 ~ 15
A
E
50
B
F
100
12.5 ~ 19.5
C
G
150
13
D
H
200
13.5 ~ 20.5
12
L1
L2
L3
323
150
286
CK CK
317
144
15
CONNECTION DIAGRAM
~ 19
Detail "D"
13
(M4 screws)
17
11th degit
code
Electronics unit
M N
Sensor unit
G1/2
See table 1
290
~ 20
(Flange)
N-h
185
150
126
100
73
38
8-19
JIS-10K-80A
210
175
151
103
96
38
8-19
JIS-10K-100A
200
160
126
100
73
42
8-23
JIS-20K-80A
210
170
126
100
73
48
8-23
240
191
195
152.5
151
126
103
100
96
73
52
44
8-25
4-20
229
190.5
151
103
96
44
8-20
ANSI/JPI-150LB-4B
Conduit conn.
K
M N
A, S
G1/2
JIS-30K-80A
B, T
1/2-14NPT
16 5
JIS-30K-100A
ANSI/JPI-150LB-3B
C, V
Pg13.5
D, W
M20 1.5
16 5
E, X
Pg13.5
210
168
126
100
73
49
8-23
ANSI/JPI-300LB-3B
254
210
200
168
151
126
103
100
96
73
52
52
8-23
8-23
ANSI/JPI-300LB-4B
ANSI/JPI-600LB-3B
200
160
126
100
73
44
8-18
DIN
PN40
DN80
220
180
151
103
96
40
8-18
DIN
PN16
DN100
17 8
4.5
4.5
Table 1
FKE...4
Head office
11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan
http://www.fujielectric.co.jp
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202
Fax: 81-42-585-6187
http://www.fic-net.co.jp
Printed in Japan