Вы находитесь на странице: 1из 48

P R O D U C T

C A T A L O G U E

KEI Industries Limited is a leading player in the power cable


segment and is one of the most respected cable manufacturing
companies in India. KEI manufactures high and low tension
cables (EHV, HT & LT), control and instrumentation cables,
house wires and stainless steel wires. It is one of the select
companies in the country to manufacture speciality cables
including braided cables, fire survival, Zero halogen cables,
Shipwiring cables and Flexible mining cables.
Established in 1968, KEI has built up it's leadership position
over a period of five decades with a customer-focused
approach and a continous quest for world-class quality.
Supported by an efficient marketing and distribution network
KEI has a reputation for strong customer support. KEI also has a
substantial international presence with a global spread of
clients spreading across 35 countries.

An ISO 9001:2000 certified company; KEI carries out stringent quality control measures under surveillance of a competent team of
technocrats and quality enablers. Continuous Product Innovations and cutting-edge R&D at KEI's in-house labs is what contributes
towards constant evolution in our offerings and services. All KEIs cables and wires are of a superior quality, a reason why they have been
accredited and certified by Testing Agencies across the globe.

Troester's CCV Line Chopanki

MANUFACTURING FACILITIES
A large infrastructure, spread over an area of 86,000 sq metres across three strategically located units, supported by state-of-the-art
production line-ups, gives KEI the strength to meet the varied needs of it's wide client base. No wonder KEI caters to over 100 large
Indian companies covering almost all the industrial sectors.

CORPORATE
OFFICE
BHIWADI
CHOPANKI (EOU)

SILVASSA

CLIENTS AND SECTORS


MINING
-

SECL
WCL
ECL
Hindustan Zinc
Marble Industries
Birla Copper

FERTILIZERS
-

National Fertilizers Ltd


Indo Gulf Fertilizers
Indian Farmers & Fertilizers Corporation
Gujrat State Fertilizers
Co-operative Corporation
Chambal Fertilizers
Deepak Fertilizers
Zuari Agro
Rashtriya Chemicals
and Fertilizers
Tata Chemicals
Hindustan Fertilizers Co. Ltd.

TELECOMMUNICATION
- Bharat Sanchar Nigam
- Basic Operators and Telecom
Networking Engineers
- Cyprus Telecommunication
- Spice Telecom
- Marconi
- Secure Meters
- Reliance Infocomm
- Defence
INTERNATIONAL EPCS
- ABB
- Mcdermott
- VA Tech Hydro and VA
Tech Flowel
- SIEMENS
- Mitsui
- Doosan
- SAMSUNG
- Itochu
- Hyundai
- LG
- Punj Llyods
- EIL
- TOYO
- BHEL
- Bechtel
- TECHNIP
- Larsen and Toubro
- TICB
- PETROFAC
- Skanska
- Alstom / Areva
- Briggs and Burton
GLOBAL SUPPLIES
- Ireland Blyth Ltd., Mauritius
- 400 KV Switchyard
Project Stage-1
- Industrial Pumps, Philippines
- Rey and Lenferna Ltd.,
Mauritius
- Baji Iraq
- BK Overseas, Ugande
- Bahri and Mazroei Trading Co., U.A.E
- Gulf Incon Doha, Qatar
- Joba Trading
- Abu Dhabi Commercial
Corporation, U.A.E
- Oman Cable
Industry, Muscat, Oman

- Min. of Electricity
and Water, Bahrain
- Ministry of Finance, Dubai
- J Ray McDermott
East Inc., Dubai
- Kuwait National
Petroleum Corporation
- Cyprus Telecom. Authority,
Nicosia, Cyprus
- Modern Electrical, Trinidad
- Kahrama, Qatar
- Al Hamas
- Innovative Technologies,
Dubai
- Qatar Petroleum
- SEWA, Sharjah
- Systems Building,
Mauritius
- Sohar Aluminium,
Dubai
- FEWA
- PPC Ltd., Canada
PRIVATE PROJECTS
-

IBM
DELL
Inox Multiplex
Hotel Taj
Biocon
MICROSOFT
ITC
ICICI
Asian Paints
TCS
CENTURY-DOMAIN
Infosys software
HSBC
Jet Airways
Balakrishna Tyres
MOSER BAER
Ranbaxy
HDFC
Sahara
Godfrey Philips
SAMTEL
PVR Multiplex
Citi Bank
Mind Space
Kala Academy

OIL AND GAS


- Oil and Natural Gas
Commission
- Gas Authority of India
- Oil india Limited
- SHELL
- PETRONET
CEMENT
- ACC
- RAS Cement
- Gujrat Ambuja
- ARM
- Jai Prakash Industries
- TCIL - TORO
- Binani Cement
- TATA Cement
- Birla Corporation
- Lafarge
- Larsen and Toubro
- Jabel Ali Cement
- Nigeria Cement
- Benue Cement

FERROUS AND NON


FERROUS METALS
-

HINDALCO
Hindustan Zinc
Steel Authority of India Ltd.
NALCO
Essar
BALCO
Jindal
Monnet Ispat
TATA
EBG India
Sponge Iron Plants

REFINERIES AND
PETROCHEMICALS
- Indian Oil
Corporation Ltd
- Bongaigaon
Refineries Ltd
- Bharat Petroleum
Corporation Ltd.
- Haldia Petrochemicals
Ltd
- Indian Petrochemicals
Ltd.
- CPCL, Chennai
- Kochi Refineries Ltd.
- MRPL, Mangalore
- National Aluminium
Co. Ltd.
- Carin Energy
- Hindustan Petroleum
Co. Ltd.
- Reliance
- Numaligarh Refineries Ltd.
POWER AND
TRANSMISSION
/DOMESTIC
- TATA Power
- BSES Limited
- Gujarat State Energy
Corporation
- Essar Power
- Nuclear Power
Corporation
- National Thermal
Power Co.
- Indian Railway
- State Electricity Boards
- Jindal Power
- DMRC
- CPWD/PWD
- CEB Mauritius
- Ahmedabad
Electricity Co. Ltd.
- Crompton and
Greaves
- Power Grid
Corporation
- Surat Electricity
Co.Ltd.
- JSPL
- ENRON
- Karnataka Power
Co. Ltd.
- JVSL
- NDPL
- GEB
- BESCOM
- MSEB
- GOA Board

PRODUCT RANGE
KEI provides a very wide range of products to its customers.
The company is perhaps one of the few to offer customers
specialty cables such as fire survival cables, zero halogen cables
and braided cables. All wires are manufactured as per global
quality and customer specifications.

EHV Cable Range - upto & including


132 kv
Low Voltage copper/aluminium
Cables
Low Voltage PVC and XPLE
Control Cables
Thermocouple Compensating &
Extension Cables
FRLS / FR / HR / HFFR / HOFR /
Rubber / LDPE / LSOH Power
Control & Instrumentation Cables
Flexible (Single & Multicore)
and Cords
Housewires
(FR / FRLS / HRPVC / LSOH')
Fire Survival
Welding Cables/Rubber Cables
Flat Cable
Mining Cable (UNDERGROUND &
OPEN CAST)
Ship Wiring Cables
Aerial Bunched Cables (AB Cables)

Bare Conductors

& MORE AS PER CUSTOMER SPECIFICATIONS


IN BS, VDE, IEC, IS AND SABS STANDARDS
(UPTO AND INCLUDING 132KV)

MV XLPE INSULATED ARMOURED CABLES


Application

Power cables for medium voltage (upto 33KV) are used in outdoor cable ducts,
cable trays, conduits or underground locations under mechanical stresses in
power and switching stations, local distribution systems and industrial plants
Standards.

BS 6622 & IEC 605022

Operating temperature
Short circuit temperature

90C
250C

Cable range manufactured 19/33 KV Screened Cables (33 KV Earth)


12.7/22 KV Screened Cables (22 KV Earth)
11/11 KV i.e. 11 KV (UE) Screened Cables
6.6/6.6 KV Screened Cables [6.6 KV (UE) & 11 KV (E)]
3.8/6.6 KV Screened Cables
3.3 KV (E) and (UE) Unscreened / Screened Cables

Test Voltage

Sizes

50 Sq.mm to 1000 Sq.mm in Single Core Cables


25 Sq.mm to 400 Sq.mm in Multi Cores Cables

Rated Voltage
Uo KV
3.8
6.35
8.7
12.7
19

Test Voltage (for 5 min.)


RMS
11
15
22
30
45

CONSTRUCTION

ISO

9001

COMPANY
8

Conductor

Aluminium / Annealed Plain Copper Stranded compacted circular conductor conform


to BS 6360 and IEC 60228, class 2

Conductor
Screening

Semi-Conducting layer over conductor

Insulation

Cross linked Polythylene to (XLPE)

Insulation
Screening

Semi-Conducting layer over insulation, in combination with Copper tape.

Core colour

Single Core Natural


Multi Core Numbered or colour polyster tapes applied over Copper tapes

Bedding

Extruded PVC

Armour

Single Core - Non-magnetic (Aluminium) wire / Flat wire Multi core - Galvanised steel
wire / Flat wire / Tape

Outer Sheath

Extruded PVC / Special PVC compound such as Flame Retardant (FR), Flame
Retardant Low Smoke (FRLS), Low Smoke Zero Halogen (LSOH) can be used for
outer sheath to suit a variety of environment and fire risk conditions. Flamabillity test
confirms to IEC 332. For installation where fire and associated problems such as
emission of smoke and toxic fumes offer a serious potential threat, special LSF (Low
smoke & fumes) compound can be provided. LSF compound is Halogen free
(Flourine, Chlorine, Bromine) when tested as per BS 6425 (Pt 1) & IEC 60754
(Pt 1). The acid gas evolved during combustion is less than 0.5% by weight of
material.

ISO-9001 REGISTERED

C024

DNV-Certification B.V. THE NETHERLANDS

Note : Unarmoured cables construction details available upon request.


**Modification which serve to improve our products will be implemented without notice.

Cables Constructions
IEC 60502-2 3/6.6 KV Single Core Alu. Wire Armoured
Nominal
cross
sectional area
mm2

Nominal
thickness
of insulation
mm

Approx.
thickness
of bedding
mm

Nominal Alu.
armour wire
diameter
mm

Nominal
Thickness of PVC
outer sheath
mm

Approx.
overall
diameter
mm

Approx. Cu.
cable
weight
Kg/Km

50
70
95
120
150
185
240
300
400
500
630
800
1000

2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2
3.2
3.2

0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6

1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.8
1.8
1.8
1.9
1.9
2.0
2.1
2.2
2.3
2.5
2.6
2.8
2.9

25
27
29
31
32
34
38
41
44
49
53
58
64

1020
1247
1530
1832
2112
2504
3171
3828
4846
6031
7351
9082
11095

717
827
974
1119
1214
1408
1751
2054
2443
3064
3653
4397
5261

1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.8
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.5
2.6
2.8
3.0

27
29
31
33
35
37
39
42
45
49
53
58
64

1121
1348
1639
1934
2312
2692
3277
3909
4907
6079
7403
9139
11188

819
928
1084
1221
1413
1596
1858
2135
2504
3112
3705
4454
5354

1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5

1.8
1.9
1.9
2.0
2.1
2.1
2.2
2.3
2.4
2.6
2.7
2.8
3.0

30
31
33
36
36
39
42
44
49
52
56
61
67

1257
1495
1796
2107
2412
2809
3473
4115
5299
6366
7688
9421
11495

955
1075
1241
1394
1513
1713
2054
2341
2896
3399
3990
4737
5661

Approx. Alu.
cable
weight
Kg/Km

IEC 60502-2 6/10 KV Single Core Alu. Wire Armoured


50
70
95
120
150
185
240
300
400
500
630
800
1000

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6

IEC 60502-2 8.7/15 KV Single Core Alu. Wire Armoured


50
70
95
120
150
185
240
300
400
500
630
800
1000

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

1.0
1.0
1.1
1.1
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.6

CCV Line

Cables Constructions
IEC 60502-2 12/20 KV Single Core Alu. Wire Armoured
Nominal
cross
sectional area
2
mm

Nominal
thickness
of insulation
mm

Approx.
thickness
of bedding
mm

Nominal Alu.
armour wire
diameter
mm

Nominal
Thickness of PVC
outer sheath
mm

Approx.
overall
diameter
mm

Approx. Cu
cable
weight
Kg/Km

50
70
95
120
150
185
240
300
400
500
630
800
1000

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

1.0
1.1
1.1
1.1
1.2
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.7

1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5

1.9
2.0
2.0
2.1
2.1
2.2
2.3
2.3
2.5
2.6
2.8
2.9
3.1

32
35
36
39
40
42
44
48
51
54
59
63
69

1382
1731
2023
2357
2662
3076
3685
4442
5497
6566
7948
9703
11785

1080
1312
1468
1643
1764
1980
2266
2668
3095
3598
4250
5018
5951

2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

2.1
2.2
2.2
2.3
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3.1
3.3

39
41
43
45
47
49
51
54
57
60
65
69
75

1839
2131
2440
2794
3239
3672
4322
5000
6062
7164
8558
10384
12522

1536
1711
1885
2080
2340
2576
2902
3226
3659
4197
4859
5699
6688

Approx. Alu.
cable
weight
Kg/Km

IEC 60502-2 18/30 KV Single Core Alu. Wire Armoured


50
70
95
120
150
185
240
300
400
500
630
800
1000

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

CCV Line

10

1.1
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.8

Medium Voltage Cable Testing

Cables Constructions
IEC 60502-2 3.6/6 KV Three Core Flat Strip Armoured
Nominal
cross
sectional area
2
mm

Nominal
thickness
of insulation
mm

Approx.
thickness
of bedding
mm

35
50
70
95
120
150
185
240
300
400

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0

1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.6
1.8
1.8

Nominal
Thickness of
outer sheath
mm

Approx.
overall
diameter
mm

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

2.2
2.3
2.4
2.5
2.6
2.7
2.9
3.0
3.2
3.5

42
44
48
52
57
59
63
69
75
83

2790
3365
4108
5049
6037
6984
8230
10237
12361
15632

2168
2455
2850
3359
3903
4294
4941
5987
7050
8438

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

2.3
2.4
2.6
2.7
2.8
2.9
3.0
3.2
3.3
3.5

46
48
52
56
61
63
67
73
78
85

3186
3709
4526
5495
6566
7451
8720
10632
12646
15951

2564
2799
3269
3804
4431
4762
5431
6383
7336
8757

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

2.6
2.7
2.8
2.9
3.0
3.2
3.3
3.5
3.7

54
58
62
66
68
73
78
83
90

4184
5080
6058
7134
8027
9362
11348
13369
16707

3275
3822
4367
5001
5338
6073
7099
8059
9513

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

2.8
2.9
3.0
3.1
3.2
3.3
3.5
3.6
3.9

59
62
66
71
73
77
83
88
95

4717
5593
6601
7711
8614
10016
12011
14028
17457

3807
4336
4910
5577
5925
6727
7762
8718
10263

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

3.1
3.2
3.4
3.5
3.6
3.7
3.9
4.0
4.2

71
75
79
84
86
90
96
101
107

6181
7176
8322
9501
10433
11852
13952
16145
19534

5272
5919
6632
7367
7743
8563
9704
10835
12340

Nominal
Dimension
G.I.Flat Strip.
mm

Approx.
Copper cable
weight
Kg/Km

Approx. Alu.
cable
weight
Kg/Km

IEC 60502-2 6/10 KV Three Core Flat Strip Armoured


35
50
70
95
120
150
185
240
300
400

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.8
1.8

IEC 60502-2 8.7/15 KV Three Core Flat Strip Armoured


50
70
95
120
150
185
240
300
400

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

1.4
1.6
1.6
1.6
1.6
1.6
1.8
1.8
1.8

IEC 60502-2 12/20 KV Three Core Flat Strip Armoured


50
70
95
120
150
185
240
300
400

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

1.6
1.6
1.6
1.6
1.6
1.8
1.8
1.8
1.8

IEC 60502-2 18/30 KV Three Core Flat Strip Armoured


50
70
95
120
150
185
240
300
400

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

1.6
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0

11

Cables Constructions
IEC 60502-2 3.6/6 KV Three Core RWA Cable
Nominal
cross
sectional area
mm2

Nominal
thickness
of insulation
mm

Approx.
thickness
of bedding
mm

Nominal
G.I. Armour wire
diameter
mm

Nominal
Thickness of
outer sheath
mm

Approx.
overall
diameter
mm

Approx.
Copper cable
weight
Kg/Km

35
50
70
95
120
150
185
240
300
400

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0

1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.6
1.8
1.8

2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.15
3.15

2.3
2.4
2.5
2.7
2.8
2.9
3.0
3.2
3.4
3.7

45
48
52
56
60
63
67
73
80
88

3457
4425
5270
6314
7419
8395
9753
11933
14957
18529

2835
3515
4013
4624
5285
5706
6464
7685
9647
11336

2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15

2.4
2.5
2.7
2.8
2.9
3.0
3.1
3.3
3.5
3.7

49
51
55
59
64
66
70
77
82
89

4271
4758
5677
6757
7936
8871
10214
13045
15257
18796

3649
3849
4419
5067
5801
6181
6925
8797
9946
11603

2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15
3.15

2.7
2.8
3.0
3.1
3.2
3.3
3.5
3.6
3.9

57
61
65
70
72
77
84
88
95

5475
6448
7557
8728
9673
11852
14074
16225
19864

4565
5190
5866
6594
6983
8563
9825
10914
12670

2.5
2.5
2.5
2.5
3.15
3.15
3.15
3.15
3.15

2.9
3.0
3.1
3.2
3.4
3.5
3.6
3.8
4.0

62
66
70
75
78
83
88
93
100

6125
7079
8188
9389
11139
12706
14866
17090
20740

5215
5821
6497
7254
8449
9417
10618
11780
13545

2.5
3.15
3.15
3.15
3.15
3.15
3.15
3.15
3.15

3.3
3.4
3.5
3.6
3.7
3.9
4.0
4.2
4.4

75
80
84
89
90
95
101
106
113

7892
9795
11071
12416
13384
15011
17212
19675
23302

6982
8536
9381
10282
10695
11722
12963
14364
16109

Approx. Alu.
cable
weight
Kg/Km

IEC 60502-2 6/10 KV Three Core RWA Cable


35
50
70
95
120
150
185
240
300
400

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.8
1.8

IEC 60502-8.7/15 KV Three Core RWA Cable


50
70
95
120
150
185
240
300
400

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

1.4
1.6
1.6
1.6
1.6
1.6
1.8
1.8
1.8

IEC 60502- 12/20 KV Three Core RWA Cable


50
70
95
120
150
185
240
300
400

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

1.6
1.6
1.6
1.6
1.6
1.8
1.8
1.8
1.8

IEC 60502- 18/30 KV Three Core RWA Cable


50
70
95
120
150
185
240
300
400
12

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

1.6
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0

Cables Constructions
BS6622 3.8/6.6 KV Single Core CU/ XLPE/Alu. Wire / PVC
Nominal
cross
sectional area
2
mm

Nominal
thickness
of insulation
mm

Minimum
thickness
of bedding
mm

Nominal
armour wire
diameter
mm

Min. Thickness
of PVC outer
sheath
mm

Approx.
overall
diameter
mm

Approx.
cable
weight
Kg/Km

50
70
95
120
150
185
240
300
400
500
630
800
1000

2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2
3.2
3.2

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.84
0.92
0.92
1.00

1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.24
1.24
1.32
1.32
1.40
1.40
1.48
1.56
1.64
1.80
1.88
1.96
2.12

24.2
25.8
27.7
29.8
30.7
33.4
36.4
39.0
42.6
47.7
51.5
56.1
61.9

1090
1340
1660
1970
2260
2760
3430
4130
5080
6490
8030
9930
12200

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.24
1.32
1.32
1.40
1.48
1.48
1.56
1.56
1.72
1.80
1.88
1.96
2.12

26.2
28.0
29.7
32.0
33.7
35.6
38.3
40.3
43.7
48.1
51.9
56.5
62.3

1200
1470
1780
2110
2500
2920
3580
4230
5180
6530
8080
9970
12250

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5

1.32
1.32
1.40
1.48
1.48
1.56
1.64
1.64
1.80
1.88
1.96
2.04
2.20

28.9
30.5
33.2
35.5
36.2
38.3
41.0
43.0
47.6
50.6
54.6
59.4
65.2

1360
1620
2050
2390
2680
3130
3800
4470
5610
6780
8370
10310
12630

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

1.60
2.00
2.00
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50

1.40
1.40
1.48
1.48
1.56
1.56
1.64
1.72
1.80
1.88
2.04
2.12
2.20

32.1
34.5
36.4
38.5
39.4
41.3
44.0
47.4
50.6
53.8
57.8
62.6
68.2

1570
1940
2290
2630
2950
3390
4070
4940
5920
7130
8740
10720
13040

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

Max.DC
Resistance
at 20oC
Ohm/Km

6.35/11KV Single Core CU/ XLPE/Alu. Wire / PVC


50
70
95
120
150
185
240
300
400
500
630
800
1000

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.84
0.92
0.92
1.0

8.7/15 KV Single Core CU/ XLPE/Alu. Wire / PVC


50
70
95
120
150
185
240
300
400
500
630
800
1000

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.84
0.84
0.92
1.00
1.08

12.7/22 KV Single Core CU/ XLPE/Alu. Wire / PVC


50
70
95
120
150
185
240
300
400
500
630
800
1000

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.84
0.84
0.92
0.92
1.00
1.08

13

MV XLPE Insulated Armoured Cables


19/33 KV Single Core CU/ XLPE/Alu. Wire / PVC
Nominal
cross
sectional area
mm2

Nominal
thickness
of insulation
mm

Minimum
Thickness
of bedding
mm

Nominal
armour wire
diameter
mm

Min. Thickness
of PVC outer
sheath
mm

Approx.
overall
diameter
mm

Approx.
cable
weight
Kg/Km

50
70
95
120
150
185
240
300
400
500
630
800
1000

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

0.76
0.76
0.76
0.76
0.84
0.84
0.84
0.92
0.92
1.00
1.00
1.08
1.16

2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

1.56
1.56
1.64
1.64
1.72
1.80
1.80
1.88
1.96
2.04
2.12
2.28
2.36

38.7
40.3
42.2
44.3
46.4
48.5
51.0
53.2
56.4
59.8
63.6
68.6
74.2

2100
2390
2770
3130
3630
4110
4810
5540
6560
7830
9460
11520
13900

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.15
3.15

1.56
1.64
1.80
1.88
1.96
2.04
2.12
2.20
2.36
2.60
2.76

40.2
42.5
46.5
50.2
54.2
59.2
60.9
65.4
72.0
79.3
87.5

3330
3850
4900
5880
7090
8360
9300
10900
13430
16950
20480

0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15

1.72
1.80
1.88
1.96
2.04
2.20
2.28
2.36
2.52
2.68
2.84

46.1
48.4
51.2
54.9
58.9
64.1
65.8
70.3
77.6
82.5
89.6

4330
4880
5540
6550
7800
9150
10100
11700
15020
17010
21040

0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15
3.15

1.88
1.96
2.04
2.12
2.20
2.28
2.36
2.52
2.68
2.76
3.00

52.1
54.4
57.2
60.9
64.9
69.9
71.6
77.6
83.6
88.3
95.6

5200
5690
6470
7420
8720
10080
11170
13660
16360
18870
22290

0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

Max.DC
Resistance
at 20oC
Ohm/Km

3.8/6.6 KV THREE CORE CU/ XLPE/ SWA / PVC


25
35
50
70
95
120
150
185
240
300
400

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0

0.76
0.76
0.84
0.84
0.92
1.00
1.00
1.08
1.16
1.24
1.40

6.35/11 KV THREE CORE CU/ XLPE/ SWA / PVC


25
35
50
70
95
120
150
185
240
300
400

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

0.84
0.84
0.92
0.92
1.00
1.08
1.08
1.16
1.24
1.32
1.40

8.7/15 KV THREE CORE CU/ XLPE/ SWA / PVC


25
35
50
70
95
120
150
185
240
300
400
14

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

0.92
0.92
1.00
1.00
1.08
1.16
1.16
1.24
1.32
1.40
1.48

Cables Constructions
12.7/22 KV Three Core CU/ XLPE/SWA/ PVC
Nominal
cross
sectional area
mm2

Nominal
thickness
of insulation
mm

Minimum
Thickness
of bedding
mm

Nominal
armour wire
diameter
mm

Min. Thickness
of PVC outer
sheath
mm

Approx.
over all
diameter
mm

Approx.
cable
weight
Kg/Km

35
50
70
95
120
150
185
240
300
400

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

1.00
1.00
1.08
1.16
1.16
1.24
1.32
1.40
1.40
1.56

2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
3.15
3.15

2.04
2.12
2.20
2.36
2.44
2.52
2.68
2.76
2.92
3.08

60.9
63.5
67.3
71.6
77.6
79.5
84.2
90.0
94.8
102.0

6440
7150
8280
9630
11930
12930
14750
17210
19720
23140

0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

3.15
3.15
3.15
3.15
3.15
3.15
3.15
3.15
3.15

2.52
2.60
2.68
2.76
2.84
2.92
3.08
3.24
3.40

78.5
82.1
86.2
91.1
92.8
97.3
103.3
108.3
115.3

10730
11870
13380
14940
16170
18050
20810
23480
27150

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

Max.DC
Resistance
at 20oC
Ohm/Km

19/33 KV Three Core CU/ XLPE/ SWA / PVC


50
70
95
120
150
185
240
300
400

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

1.24
1.24
1.32
1.40
1.40
1.48
1.56
1.64
1.72

Impulse Testing Lab

15

Conductor Technical Data for single Core and Multicore cables conforming to IEC 60228 (Stranded-Class-2) Aluminium Conductors and annualed copper conductors,
stranded circular, compacted circular or shaped
Nominal size of

Short Circuit Rating (ISC) for XLPE cables

Max. D.C. Resistance at 20oC

Conductor

Copper

Aluminium

Plain Copper

Aluminium

mm2

KA/sec

KA/sec

/Km

/Km

Max. A.C. Resistance at 90oC


Plain Copper

Aluminium

/Km

/Km

1.5
2.5
4.0
6.0
10
16

0.21
0.36
0.57
0.85
1.42
2.27

0.38
0.56
0.94
1.50

12.200
7.410
4.610
3.080
1.830
1.150

7.410
4.610
3.080
1.910

15.430
9.450
5.880
3.930
2.330
1.470

9.480
5.900
3.490
2.420

25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

3.60
5.00
7.10
10.0
13.6
17.1
21.4
26.4
34.3
42.9
57.1
71.4
90.0
114.3
142.9

2.40
3.30
4.70
6.60
9.00
11.3
14.2
17.5
22.6
28.3
37.7
47.2
59.4
75.5
94.3

0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

1.200
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
0.0367
0.0291

0.930
0.671
0.495
0.343
0.247
0.196
0.159
0.127
0.0965
0.0769
0.0602
0.0468
0.0362
0.0283
0.0225

1.540
1.110
0.820
0.567
0.410
0.324
0.264
0.210
0.160
0.130
0.100
0.0774
0.0600
0.0470
0.0372

Short Circuit Current Ratings for XLPE Cables


Short Circuit Rating for I second duration for Copper and Aluminium XLPE Cables (Isc Current in KAmps)
Ratings for any other duration :
1) Max. Initial Conductor Temperature during operation : 90oC
2) Max. Final Conductor Temperature during short circuit : 250oC
Formula relating short Circuit Rating with t second duration
1t=1sc t
Where 1t = Short Circuit Rating for t seconds.
t = Duration in seconds.
1sc = Short Circuit rating for 1 second.
Emergency overload : Cable may operate under overload conditions. Under such condition conductor temperature not to exceed 130o C for maximum 100 hours per year
and not more that 500 hours during lifetime of cable. This is approximately 20% higher than specified rated current during the emergency period.

CCV Line

16

Current ratings for single core cable with XLPE insulation


Rated Voltage 3.6/6 KV to 18/30 KV Copper Conductor
o

Buried direct in the ground 20 C

In single-way ducts 20 C

In Air 30 C

Nominal area of
conductor

Trefoil

Flat spaced

Trefoil
Ducts

Flat touching
ducts

mm2

109
140
166
196
239
285
323
361
406
469
526
590
650
730
820
930

113
144
172
203
246
293
332
366
410
470
524
572
710
790
910
1030

103
132
157
186
227
271
308
343
387
447
504
564
-

104
133
159
188
229
274
311
347
391
453
510
571
-

125
163
198
238
296
361
417
473
543
641
735
845
950
1070
1200
1360

128
167
203
243
303
369
426
481
550
647
739
837
-

150
196
238
286
356
434
500
559
637
745
846
938
1090
1260
1410
1610

Trefoil

0.5 De

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Maximum conductor temperature


Ambient air temperature
Ground temperature
Depth of playing
Thermal resistivity of soil
Thermal resistivity of earthenware ducts
Screens bonded at both ends.

Flat touching

0.5 De

Flat spaced

0.5 De

90oC
30oC
20oC
0.8 m
1.5 K.m/W
1.2 k.m/W

Lead Sheathing

17

Current ratings for single-core cables with XLPE insulation-rated voltage 3.6/6 KV to 18/30 KV
Aluminium conductor
Buried direct in the ground 20o C

In single-way ducts 20o C

In Air 30o C

Nominal area of
conductor

Trefoil

Flat spaced

Trefoil
Ducts

Flat touching
ducts

mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

84
108
129
152
186
221
252
281
317
367
414
470
520
590
670
750

88
112
134
157
192
229
260
288
324
373
419
466
560
640
720
800

80
102
122
144
176
210
240
267
303
351
397
451
-

81
103
123
146
178
213
242
271
307
356
402
457
-

97
127
154
184
230
280
324
368
424
502
577
673
660
740
840
950

99
130
157
189
236
287
332
376
432
511
586
676
-

116
153
185
222
278
338
391
440
504
593
677
769
760
850
960
1100

Trefoil

0.5 De

Flat touching

0.5 De

Flat spaced

0.5 De

90oC
30oC
20oC
0.8 m
1.5 K.m/W
1.2 k.m/W

Maximum conductor temperature


Ambient air temperature
Ground temperature
Depth of playing
Thermal resistivity of soil
Thermal resistivity of earthenware ducts
Screens bonded at both ends.

Current ratings for three-core cables with XLPE insulation-rated voltage 3.6/6 KV to 18/30 KV
Copper conductor Armoured and Unarmoured
Unarmoured
Nominal area of
conductor

In a Buried
duct 20o C

In Air
30o C

Buried Direct
in ground 20o C

In a Buried
duct 20o C

In Air
30o C

mm2

16
25
35
50
70
95
120
150
185
240
300
400

101
129
153
181
221
262
298
334
377
434
489
553

87
112
133
158
193
231
264
297
336
390
441
501

109
142
170
204
253
304
351
398
455
531
606
696

101
129
154
181
220
263
298
332
374
431
482
541

88
112
134
158
194
232
264
296
335
387
435
492

110
143
172
205
253
307
352
397
453
529
599
683

Maximum conductor temperature


Ambient air temperature
Ground temperature
Depth of playing
Thermal resistivity of soil
Thermal resistivity of earthenware ducts
Screens bonded at both ends.
18

Armoured

Buried Direct
in ground 20o C

90oC
30oC
20oC
0.8 m
1.5 K.m/W
1.2 k.m/W

Current ratings for three core XLPE insulated cables rated voltage 3.6/6 KV. to 18/30 KV
Aluminium conductor, Armoured and Unarmoured
Unarmoured

Armoured

Nominal area of
conductor

Buried Direct
in ground 20o C

In a Buried
duct 20o C

In Air
30o C

Buried Direct
in ground 20o C

In a Buried
duct 20o C

In Air
30o C

mm2

16
25
35
50
70
95
120
150
185
240
300
400

78
100
119
140
171
203
232
260
294
340
384
438

67
87
103
122
150
179
205
231
262
305
346
398

84
110
132
158
196
236
273
309
355
415
475
552

78
100
119
140
171
204
232
259
293
338
380
432

68
87
104
123
150
180
206
231
262
304
343
393

85
111
133
159
196
238
274
309
354
415
472
545

Maximum conductor temperature


Ambient air temperature
Ground temperature
Depth of playing
Thermal resistivity of soil
Thermal resistivity of earthenware ducts
Screens bonded at both ends.

90oC
30oC
20oC
0.8 m
1.5 K.m/W
1.2 k.m/W

19

XLPE INSULATED ARMOURED CABLES


Application

Indoors or Outdoors in cable ducts, cable trays, conduits or underground


locations under mechanical stresses in power and switching stations.
Local distribution systems, Industrial and Commercial units for basic power
& lighting purpose.
Standards

BS 5467, IEC 60502-1& VDE 0276

Operating Temperature

90 C

Short Circuit Temp.

250 C

Working Voltage

600 / 1000 Volts

Test Voltage

3.5 KV r m s for 5 minutes

CONSTRUCTION
Conductor

Aluminium / Annealed plain copper solid* / stranded conductor conform to BS 6360


and IEC 60228 Class 2 (Circular / Sector shaped)

Insulation

Cross linked polyethylene (XLPE)

Core Colour

Single core
2 Core
3 Core
4 Core
5 Core
6 Core & above

Red or Black
Red , Black
Red , Yellow , Blue
Red , Yellow, Blue, Black
Red , Yellow, Blue, Black & Yellow - Green
Black colour with number printing

Assembly

Insulated conductors are laid up together, if necessary interstices may be filled with
fillers.

Fillers

Non-hygroscopic Poly propylene fillers are included between laid up cores wherever
required.
A separator tape of non-hygroscopic poly propylene material is applied over laid up
core wherever necessary.

Bedding

Extruded PVC compatible with operating temperature

Armour

For Single Core - Aluminium round wire / flat wire. For Multicore - Galvanised Steel
round wire / flat wire / tape.

Outer Sheath

Extruded PVC / Special PVC compound such as Flame Retardant (FR), Flame
Retardant Low Smoke (FRLS), Low Smoke Zero Halogen (LSOH) can be used for
outer sheath to suit a variety of environment and fire risk conditions. Flamabillity test
confirms to IEC 332 & Swidish chimeny. For installation where fire and associated
problems such as emission of smoke and toxic fumes offer a serious potential threat,
special LSF (Low smoke & fumes) compound can be provided. LSF compound is
Halogen free (Flourine, Chlorine, Bromine) when tested as per BS 6425 (Pt 1) & IEC
60754 (Pt 1). The acid gas evolved during combustion is less than 0.5% by weight of
material.
Minimum Bending radius 12 times the cable diameter
Admissible Pulling Force Aluminium - 30N/mm2 Copper - 50N/mm2

ISO

9001

COMPANY
20

ISO-9001 REGISTERED

C024

DNV-Certification B.V. THE NETHERLANDS

Note : Unarmoured cables construction details available upon request.


*Aluminium - upto 10 mm2 Copper - upto 6 mm2
**Modification which serve to improve our products will be implemented without notice.

Cables Constructions
IEC 60502-1 0.6/1.0 KV Single Core XLPE/PVC/RWA/PVC
Nominal
cross
sectional area
mm2

Nominal
thickness
of insulation
mm

Approx.
Thickness
of bedding
mm

Nominal Alu.
armour wire
diameter
mm

Nominal
Thickness of
outer sheath
mm

Approx.
overall
diameter
mm

25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00
2.20
2.40
2.60
2.80

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4

0.8
0.8
1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.1
2.2
2.3
2.5
2.7

15.5
16.5
19.0
21.0
22.5
25.5
26.5
29.0
32.0
34.0
39.0
43.0
47.0
53.5
59.5

IEC 60502-1 0.6/1.0 KV Two Cores XLPE/PVC/RWA/PVC

Approx.
Copper Cable
weight
Kg/Km

Approx.
Alu. Cable
weight
Ohm/Km

447
553
757
978
1,233
1,559
1,854
2,226
2,791
3,378
4,502
5,506
6,796
8,757
10,782

300
346
454
558
677
846
955
1,130
1,372
1,604
2,099
2,539
3,098
4,072
4,948

Approx.
Approx.
copper
Alu.
cable
Cable
weight
weight
Kg/Km Kg/Km

XLPE/PVC/FSA/PVC

Nominal
cross
sectional
area
mm2

Nominal
thickness
of
insulation
mm

Approx.
Thickness
of
bedding
mm

Nominal
G.I.
armour wire
diameter
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.7
0.7
0.7
0.7
0.7
0.7
0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6

0.8
0.8
0.8
0.8
1.25
1.25
1.60
1.60
1.60
1.60
2.00
2.00
2.00
2.50
2.50
2.50
2.50

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.1
2.2
2.3
2.5
2.7
2.8
3.1

14.0
15.0
16.0
17.0
20.0
22.0
21.0
22.5
24.5
27.5
31.5
34.5
37.0
42.0
46.0
50.0
55.0

mm

Approx.
Approx.
Copper
Alu.
Cable
Cable
weight
weight
Kg/Km Kg/Km
325
372
444
520
802
995
1124
1367
1714
2212
2993
3579
4282
5480
6712
8108
10204

298
328
397
446
680
807
830
952
1107
1374
1865
2155
2490
3287
3880
4568
5408

Nominal
dimension
G.I. Flat
Strip
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

1.8
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.6
2.7
3.0

19.5
21.0
23.0
26.0
29.0
31.5
34.5
38.5
42.0
46.5
51.5

mm

936
1158
1507
1964
2500
3059
3713
4546
5670
6947
8958

642
742
901
1126
1372
1636
1920
2353
2838
3407
4163

Testing Lab

21

Cables Constructions
IEC 60502-1 0.6/1.0 KV Three Cores XLPE/PVC/RWA/PVC

XLPE/PVC/FSA/PVC

Nominal
cross
sectional
area
2
mm

Nominal
thickness
of
insulation
mm

Approx.
Thickness
of
bedding
mm

Nominal
G.I.
armour wire
diameter
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.7
0.7
0.7
0.7
0.7
0.7
0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6

0.8
0.8
0.8
0.8
1.25
1.25
1.60
1.60
1.60
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.5
2.6
2.8
3.0
3.2

14.5
15.5
16.5
18.0
21.0
23.0
23.5
25.0
28.5
33.0
36.5
39.5
44.5
48.5
53.0
59.5
64.5

mm

Approx.
Approx.
Copper
Alu.
Cable
Cable
weight
weight
Kg/Km Kg/Km
353
411
497
597
922
1172
1474
1787
2348
3252
4092
4934
6367
7608
9378
11434
14456

314
345
427
486
738
890
1032
1165
1439
1995
2401
2800
3678
4319
5130
6123
7262

IEC 60502-1 0.6/1.0 KV Four Cores with reduced Neutral XLPE/PVC/RWA/PVC


Nominal
cross
sectional
area
mm2

Nominal
thickness
of
insulation
mm

Approx.
Thickness
of
bedding
mm

Nominal
G.I.
armour wire
diameter
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

25
35
50
70
95
120
150
185
240
300
400

0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00

1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6

1.60
1.60
1.60
2.00
2.00
2.00
2.50
2.50
2.50
2.50
3.15

1.8
1.8
1.9
2.1
2.2
2.4
2.5
2.7
2.9
3.0
3.3

24.5
26.0
29.5
34.5
38.0
41.5
46.5
51.5
57.5
61.5
69.0

mm

1117
1270
1552
2197
2660
3145
4049
4804
5808
6713
8806

IEC 60502-1 0.6/1.0 KV Four Cores XLPE/PVC/RWA/PVC

22

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

1.8
1.8
1.8
2.0
2.1
2.2
2.3
2.5
2.7
2.8
3.1

22.0
23.5
27.0
30.5
33.5
37.0
41.0
45.0
49.5
55.5
61.0

mm

Approx.
Approx.
Copper
Alu.
Cable
Cable
weight
weight
Kg/Km Kg/Km

1258
1565
2069
2774
3548
4340
5348
6465
8152
10009
12960

817
943
1160
1516
1857
2206
2659
3176
3903
4698
5766

XLPE/PVC/FSA/PVC

Approx.
Approx.
Copper
Alu.
Cable
Cable
weight
weight
Kg/Km Kg/Km
1652
1987
2608
3663
4653
5698
7156
8656
10769
12920
17096

Nominal
dimension
G.I. Flat
Strip.
mm

Nominal
dimension
G.I. Flat
Strip.
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

1.8
1.8
1.9
2.1
2.2
2.3
2.5
2.7
2.9
3.1
3.4

23.0
24.5
27.5
32.0
35.5
39.0
43.0
48.0
54.0
58.5
65.0

mm

Approx.
Approx.
Copper
Alu.
Cable
Cable
weight
weight
Kg/Km Kg/Km
1446
1758
2351
3159
4077
5088
6086
7467
9448
11547
14901

910
1042
1295
1694
2083
2535
2978
3614
4487
5339
6611

XLPE/PVC/FSA/PVC

Nominal
cross
sectional
area
mm2

Nominal
thickness
of
insulation
mm

Approx.
Thickness
of
bedding
mm

Nominal
G.I.
armour wire
diameter
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.7
0.7
0.7
0.7
0.7
0.7
0.90
0.90
1.00
1.10
1.10
1.20
1.40
1.60
1.70
1.80
2.00

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8

0.8
0.8
0.8
1.25
1.25
1.60
1.60
1.60
1.60
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.5
2.6
2.8
3.0
3.2
3.5

15.5
16.5
18.0
20.0
22.5
25.5
25.0
27.0
30.5
35.5
39.5
44.5
47.5
53.0
59.0
65.0
74.0

mm

Approx.
Approx.
Copper
Alu.
Cable
Cable
weight
weight
Kg/Km Kg/Km
393.2
465.8
574.0
828.7
1076.1
1525.3
1761.2
2201.1
2893.0
4033.8
5141.9
6630.8
7952.6
9565.0
11941.3
14495.5
19476.0

340.5
378.6
480.1
680.6
832.1
1149.3
1172.2
1370.4
1680.7
2356.7
2887.4
3784.3
4367.4
5180.3
6276.7
7415.0
9883.9

Nominal
dimension
G.I. Flat
Strip.
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

1.8
1.8
1.9
2.1
2.2
2.3
2.5
2.7
2.9
3.1
3.4

23.5
25.0
29.0
33.0
37.0
40.5
44.0
49.5
55.5
61.0
69.0

mm

Approx.
Approx.
Copper
Alu.
Cable
Cable
weight
weight
Kg/Km Kg/Km

1539.3
1944.8
2615.4
3490.0
4523.5
5587.7
6847.2
8338.3
10580.0
12999.4
16990.5

950.2
1114.1
1403.0
1812.8
2269.0
2741.2
3262.0
3953.6
4915.3
5918.8
7398.4

IEC 60502-1 0.6/1.0 KV Control Cables CU/XLPE/PVC/RWA/PVC


No.
of
cores

Nominal
cross
sectional
area
mm

Nominal
thickness
of
insulation
mm

Approx.
Thickness
of
bedding
mm

Nominal
G.I.
armour wire
diameter
mm

2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
43
47

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

0.8
0.8
0.8
0.8
0.8
0.8
1.3
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
1.6
1.6

No.
of
cores
mm2

Nominal
cross
sectional
area
mm

Nominal
thickness
of
insulation
mm

Approx.
Thickness
of
bedding
mm

Nominal
G.I.
armour wire
diameter
mm

2
3
4
5
6
7
10
12
14
16
19
24
27
30
37
40
43
47

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2

0.8
0.8
0.8
0.8
1.25
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0

mm

CU/XLPE/PVC/FSA/PVC

Nominal Approx.
Approx.
Thickness overall
Copper
of outer diameter
Cable
sheath
weight
mm Kg/Km Kg/Km
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
1.9

14.0
14.5
15.5
16.5
17.5
17.5
21.5
22.0
22.5
23.5
24.5
28.0
28.5
29.5
31.5
32.5
33.5
34.5

334
360
404
452
503
511
838
885
954
1031
1118
1543
1593
1695
1910
2046
2172
2307

Nominal Approx.
Approx.
Thickness overall
Copper
of outer diameter
Cable
sheath
weight
mm Kg/Km Kg/Km
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.0
2.0
2.1

15.0
15.5
16.5
17.5
19.5
19.5
23.0
23.5
24.5
26.0
27.0
30.5
31.0
32.5
34.5
35.5
37.5
39.5

378
418
477
537
731
746
1003
1077
1167
1406
1536
1905
1997
2129
2434
2608
3009
3254

Nominal
dimension
G.I. Flat
Strip.
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter
mm

Approx.
Copper
Cable
weight
Kg/Km

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9

21.5
22.5
23.5
26.5
27.0
28.0
29.5
31.0
32.0
33.0

872
930
1023
1277
1352
1423
1616
1731
1850
1993

Nominal
dimension
G.I. Flat
Strip.
mm

Nominal
Thickness
of outer
sheath
mm

Approx.
overall
diameter
mm

Approx.
Copper
Cable
weight
Kg/Km

4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8
4 X 0.8

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
1.9
2.0

22.0
22.5
23.5
24.5
25.5
29.0
29.5
30.5
32.5
34.0
35.0
37.0

922
977
1072
1178
1301
1627
1703
1830
2111
2262
2419
2638

PVC Extrusion Extruder

23

Current ratings for 0.6/1.0 KV XLPE cables


Copper Conductor Cable
In ground 200C

Conductor
size

2-core

Single-core

Sq mm

Trifoil

Flat 3 cables

Amp

Amp

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

28
38
49
62
82
108
140
166
197
239
287
325
363
404
465
519
573
634
697
736
781

In air 300C

206
249
295
333
366
402
454
498
528
571
611
630
661

3-or-4 core

Single-core
Trifoil

Flat 3 cables
Amp

Amp

Amp

Amp

34
44
58
72
96
125
159
191
225
273
328
373
418
466
539
603
677

29
37
49
61
81
106
132
158
189
229
275
313
350
390
451
505
565

27
37
44
56
78
105
139
174
222
285
346
402
463
529
625
720
815
918
1027
1119
1214

40
50
69
96
120
144
171
208
248
266
304
349
406
450
487

27
35
44
81
101
121
144
175
210
239
268
301
349
393
437

34
43
58
80
109
123
162
207
252
292
337
391
465
540
661
748
846
976
1063

141
176
288
358
425
485
549
618
715
810
848
923
992
1042
1110

2-core

3-or-4 core

Amp

Amp

29
39
52
67
90
115
152
188
228
291
354
410
472
539
636
732
847

24
33
45
56
78
99
131
162
197
251
304
353
406
463
546
628
728

37
48
65
85
112
138
166
211
254
235
269
308
364
409
573

32
41
55
74
98
120
145
185
224
264
305
350
418
488
562

Aluminium Conductor Cable


4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
Ground temperature
Ground thermal resistivity

24

39
49
65
84
109
127
151
184
219
250
279
312
361
405
475
540
610
680
760

158
191
228
258
286
317
363
403

20oC
1.5 K.m/W

Depth of laying
An ambient air temperature

750 mm
30oC

109
135
215
270
324
372
424
477
554
626

Cables Constructions
BS 5467 0.6/1KV Single Core CU/XLPE/PVC/SWA/PVC
Nominal
cross
sectional area
2
mm
50
70
95
120
150
185
240
300
400
500
630
800
1000

Nominal
thickness
of insulation
mm

Thickness
of
bedding
mm

Nominal
AL wire
armour dia.
mm

Thickness
of outer
sheath
mm

Approx.
overall
diameter
mm

Approx.
cable
weight
Kg/Km

Max.
DC Resistance
at 200C
Ohm/Km

1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6
2.8

0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4

0.9
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5

1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.5

16.5
19.0
21.0
23.0
25.5
27.5
30.0
32.5
37.0
40.5
44.5
51.5
56.5

1135
1525
1916
2418
2985
3422
4641
5282
7049
7645
9681
12090
14257

0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8

12.0
13.0
14.0
15.0
17.0
19.5
20.0
22.0
24.5
27.0
30.5
33.0
36.0
40.5
44.0
47.5
53.0

409
465
567
679
846
1190
1265
1646
2065
2604
3506
4287
5041
6296
8156
9514
11960

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5

1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9

12.5
13.5
14.5
15.5
18.5
20.0
23.0
25.0
27.5
31.0
35.0
37.5
42.0
46.0
50.5
56.0
62.0

437
502
623
744
1070
1330
1721
2111
2632
3385
4585
5617
7040
8286
10769
12797
16043

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

BS 5467 0.6/ 1 KV Two Core CU/XLPE/PVC/SWA/PVC


1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6

BS 5467 0.6/ 1 KV Three Core CU/XLPE/PVC/SWA/PVC


1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6

25

Cables Constructions
BS 5467 0.6/ 1 KV Four Core Cu/XLPE/PVC/SWA/PVC
Nominal
cross sectional
area
mm2

Nominal
thickness of
insulation
mm

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

Thickness
of
bedding
mm

0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

Nominal
armour
wire
mm

0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8

Thickness
of outer
sheath
mm

0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15

Approx.
overall
diameter
mm

1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
3.2

Approx.
cable
weight
Kg/Km

13.0
14.0
15.5
17.5
20.0
22.0
25.0
27.0
30.5
35.0
38.5
43.5
46.5
51.5
57.5
62.5
71.5

474
586
725
967
1265
1572
2074
2567
3236
4538
5859
7459
8835
10965
13522
16489
21046

Max.
DC Resistance
at 20C
Ohm/Km
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

BS 5467 0.6/ 1KV Four Core with Reduced Neutral Cu/XLPE/PVC/SWA/PVC


Nominal
cross
sec. area
Phase
mm2
25
35
50
70
95
120
150
185
240
300
400

26

Nominal
cross
sec. area
Neutral
mm2

Nominal
thickness
of insulation
Phase
mm

Nominal
thickness of
insulation
Neutral
mm

Thickness
of
bedding

Nominal
armour
wire dia.

Thickness
of outer
sheath

Approx.
overall
diameter

Approx.
cable
weight

Max. DC
Resistance
at 20C

mm

mm

mm

mm

Kg/Km

Ohm/Km

16
16
25
35
50
70
70
95
120
150
185

0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.4
1.6

1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6

1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5

1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
3.0

24.5
27.0
29.0
33.5
37.0
40.5
45.5
49.5
55.0
60.5
66.5

1990
2399
2930
4157
5357
6473
7896
9932
12155
14982
18116

0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

Cables Constructions
BS 5467 0.6/1 KV Control Cables Cu/XLPE/PVC/SWA/PVC
Nominal
cross
sectionalarea
mm2
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0

No.
of
cores

Nominal
thickness
ofinsulation
mm

Thickness
of
bedding
mm

Nominal
armour wire
diameter
mm

Thickness
of outer
sheath
mm

Approx.
overall
diameter
mm

7
12
19
27
37
48
7
12
19
27
37
48
7
12
19
27
37
48

0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

0.8
0.8
0.8
1.0
1.0
1.0
0.8
0.8
1.0
1.0
1.0
1.2
0.8
1.0
1.0
1.0
1.2
1.2

0.9
1.25
1.25
1.6
1.6
1.6
0.9
1.25
1.6
1.6
1.6
2.0
1.25
1.6
1.6
1.6
2.0
2.0

1.4
1.5
1.6
1.7
1.7
1.8
1.4
1.6
1.7
1.8
1.8
2.0
1.5
1.6
1.7
1.9
2.0
2.1

15.2
19.4
22.2
26.7
29.0
32.7
17.1
22.4
26.6
30.7
33.8
39.3
19.7
25.7
29.3
34.4
39.2
44.1

Approx.
cable
weight
Kg/Km
430
720
945
1405
1685
2040
555
950
1440
1860
2270
3105
820
1365
1820
2405
3315
4040

Max.
DC Resistance
at 200C
Ohm/Km
12.1
12.1
12.1
12.1
12.1
12.1
7.41
7.41
7.41
7.41
7.41
7.41
4.61
4.61
4.61
4.61
4.61
4.61

Multiple Drum Twister

27

PVC INSULATED ARMOURED CABLES


Application

Indoors or Outdoors in cable ducts, cable trays, conduits or underground


locations under mechanical stresses in power and switching stations.
Local distribution systems, Industrial and Commercial units for basic power
& lighting purpose.
Standards

BS 6346, IEC 60502-1 & VDE 0271

Operating Temperature

70 C

Short Circuit Temp.

160 C

Working Voltage

600 / 1000 Volts

Test Voltage

3.5 KV r m s for 5 minutes

CONSTRUCTION
Conductor

Aluminium / Annealed plain copper solid* / stranded conductor conform to BS 6360


and IEC 60228, Class 2 (Circular / Sector shaped)

Insulation

PVC type TI1 as per BS 7655: Section 3.1 and PVC type A as per IEC 60502-1
Single core
2 Core
3 Core
4 Core
5 Core
6 Core & above

Red or Black
Red , Black
Red , Yellow , Blue
Red , Yellow, Blue, Black
Red , Yellow, Blue, Black & Yellow - Green
Black colour with number printing

Assembly

Insulated conductors are laid up together, if necessary interstices may be filled with
fillers.

Fillers

Non-hygroscopic Poly propylene fillers are included between laid up cores wherever
required
A separator tape of non-hygroscopic poly propylene material is applied over laid up cores
wherever necessary.

Bedding

Extruded PVC compatible with operating temperature.

Armour

For Single Core - Aluminium round wire / flat wire.


For Multicore - Galvanised Steel round wire / flat wire / tape.

Outer Sheath

Extruded PVC / Special PVC compound such as Flame Retardant (FR), Flame Retardant
Low Smoke (FRLS), Low Smoke Zero Halogen (LSOH) can be used for outer sheath to
suit a variety of environment and fire risk conditions. Flamabillity test confirms to IEC 332
& Swidish chimeny. For installation where fire and associated problems such as
emission of smoke and toxic fumes offer a serious potential threat, special LSF (Low
smoke & fumes) compound can be provided. LSF compound is Halogen free (Flourine,
Chlorine, Bromine) when tested as per BS 6425 (Pt 1) & IEC 60754 (Pt 1). The acid gas
evolved during combustion is less than 0.5% by weight of material.
Minimum Bending radius :12 times the cable diameter
Admissible Pulling Force : Aluminium - 30N/mm2

ISO

9001

COMPANY
28

ISO-9001 REGISTERED

Note : Unarmoured cables construction details available upon request.


*Aluminium - upto 10 mm2 Copper - upto 6 mm2

C024

DNV-Certification B.V. THE NETHERLANDS

**Modification which serve to improve our products will be implemented without notice.

Cables Constructions
BS 6346 0.6/ 1 KV Single Core Cu/PVC/PVC/SWA/PVC
Nominal
cross
sectional area
mm2

Nominal
thickness
of insulation
mm

Thickness
of
bedding
mm

Nominal
AL armour
wire diameter
mm

Thickness
of outer
sheath
mm

50
70
95
120
150
185
240
300
400
500
630
800
1000

1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8
2.8
3.0

0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4

1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5

1.5
1.6
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.1
2.2
2.4
2.5

18.5
20.5
22.5
26.0
27.0
29.5
32.5
35.0
40.0
43.5
47.5
53.5
59.5

780
1005
1288
1654
1969
2375
2983
3607
4794
5848
7154
9087
11162

0.387
0.268
0.193
0.153
0.124
0.0991
0.754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
1.9
2.1
2.2
2.3
2.4
2.5
2.7
2.9

12.0
13.5
15.0
16.0
20.0
22.0
22.0
24.0
26.5
28.5
33.0
35.5
38.5
43.5
47.0
51.5
56.5

258
311
431
516
826
1021
1208
1467
1864
2319
3187
3758
4485
5709
6998
8437
10592

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5

1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
3.0

12.5
14.0
15.5
17.5
21.0
23.0
25.0
26.5
30.5
34.0
38.0
40.5
46.0
50.0
54.5
61.0
66.5

287
357
490
689
957
1212
1577
1911
2522
3410
4349
5149
6648
7893
9768
11906
14996

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.288
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

Approx.
overall
diameter
mm

Approx.
cable
weight
Kg/Km

Max.
DC Resistance
at 20C
Ohm/Km

BS 6346 0.6/ 1 KV Two Core Cu/PVC/PVC/SWA/PVC


1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6

0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6

BS 6346 0.6/ 1 KV Three Core Cu/PVC/PVC/SWA/PVC


1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6

0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6

29

PVC Insulated Armoured Cables


BS 6346 0.6/ 1 KV Four Core Cu/PVC/PVC/SWA/PVC
Nominal
cross sectional
area
mm2

Nominal
thickness of
insulation
mm

Thickness
of
bedding
mm

Nominal
armour
wire
mm

Thickness
of outer
sheath
mm

Approx.
overall
diameter
mm

Approx.
cable
weight
Kg/Km

Max.
DC Resistance
at 20C
Ohm/Km

1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6

0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.8

0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15

1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
3.0
3.3

13.5
15.0
18.0
19.0
22.5
26.5
27.0
28.5
34.0
36.5
41.5
44.5
49.5
55.0
61.0
67.0
76.0

329
411
670
806
1125
1623
1917
2364
3358
4238
5459
6545
8274
9989
12436
15141
20181

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

BS 6346 0.6/ 1 KV Four Core with Reduced Neutral Cu/PVC/PVC/SWA/PVC

30

Nominal
cross
sec. area
Phase
2
mm

Nominal
cross
sec. area
Neutral
2
mm

Nominal
thickness
of insulation
Phase
mm

Nominal
thickness of
insulation
Neutral
mm

Thickness
of
bedding

Nominal
armour
wire dia.

Thickness
of outer
sheath

Approx.
overall
diameter

Approx.
cable
weight

Max. DC
Resistance
at 20C

mm

mm

mm

mm

Kg/Km

Ohm/Km

25
35
50
70
95
120
150
185
240
300
400

16
16
25
35
50
70
70
95
120
150
185

1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6

1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8
2.0

1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8

1.8
1.8
1.9
2.0
2.2
2.3
2.4
2.5
2.7
2.9
3.1

26.0
27.5
31.5
35.5
40.0
44.0
48.0
52.5
59.0
64.0
71.5

1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15

1799
2127
2807
3830
4966
6353
7445
8973
11210
13525
17839

0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

Cables Constructions
0.6/1KV Auxilliary Cables Cu/PVC/PVC/SWA/PVC
Nominal
cross
sectional area
mm2
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0

No.
of
cores

Nominal
thickness
of insulation
mm

Thickness
of
bedding
mm

Nominal
armour wire
diameter
mm

Thickness
of outer
sheath
mm

Approx.
overall
diameter
mm

7
12
19
27
37
48
7
12
19
27
37
48
7
12
19
27
37
48

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0

0.8
0.8
0.8
1.0
1.0
1.0
0.8
0.8
1.0
1.0
1.0
1.2
0.8
1.0
1.0
1.2
1.2
1.2

0.9
1.25
1.25
1.6
1.6
1.6
1.25
1.25
1.6
1.6
1.6
2.0
1.25
1.6
1.6
2.0
2.0
2.0

1.4
1.5
1.6
1.7
1.8
1.9
1.5
1.6
1.7
1.8
1.9
2.1
1.6
1.7
1.8
2.0
2.1
2.2

15.2
19.4
22.2
26.7
29.2
32.9
18.0
22.4
26.6
30.7
34.0
39.5
20.5
26.8
30.5
37.1
40.8
46.0

Approx.
cable
weight
Kg/Km

Max.
DC Resistance
at 20C
Ohm/Km

450
750
990
1470
1790
2170
680
995
1505
1985
2410
3290
890
1510
2015
2940
3660
4485

12.1
12.1
12.1
12.1
12.1
12.1
7.41
7.41
7.41
7.41
7.41
7.41
4.61
4.61
4.61
4.61
4.61
4.61

Current Ratings Copper Conductor PVC Insulated Armoured cable 600/1000 V


Conductor
size
2

mm
16
25
35
50
70
95
120
150
185
240
300
400

IN AIR
Single Core
Flat
Trefoil
(A)
(A)
181
231
280
324
373
425
501
567
657

230
286
338
385
436
490
566
616
674

2-Core

3 or 4 Core

(A)

(A)

97
128
157
190
241
291
336
386
439
516
592
683

83
110
135
163
207
251
290
332
378
445
510
590

Single Core
Flat
Trefoil
(A)
(A)
203
248
297
337
376
423
485
542
600

211
257
305
341
377
417
469
515
549

IN GROUND
2-Core

3 or 4 Core

(A)

(A)

119
158
190
225
277
332
377
422
478
551
616
693

101
132
159
188
233
279
317
355
401
462
517
580

Testing Lab

31

INSULATED FIXED / FLEXIBLE CORDS & WIRES


Application

Installation in surface mounted or embedded conduits or similar closed systems.


indoors, building wires, power cords and domestic electrical wiring purpose.

Test Voltage

Standards

BS 6004, IEC 60227-3, BS 6007, BS 7919, BS


7211, BS 6231, BS 6141, BS 4737, BS 6500,
<HAR>

Operating Temperature

70C, 90C

Working Voltage

300/500, 450/750 Volts

Maximum Short Circuit


Temperature

160C

After immerse in water for 12 hours test voltage applied for 5 minutes Thickness of
insulation upto and including
0.7 mm
0.7 mm to 1.0 mm
1.0 mm and above

1.5 KV a.c.
2.0 KV a.c.
2.5 KV a.c.

TYPE OF
2491LSF, 6491X, 6491LSF, 6241Y, 6242Y, 6243Y, 6181Y, 6181XY, 6181LSF, 318Y,
WIRES/CORDS 309Y, 218Y, 318LSF, 638TQ, 318TRS, 318TQ, 318XY, 380TQ, 680TQ,
Conductor

Solid (class 1), Stranded (class 2), flexible (class 5), annealed copper conductor
conforming to BS 6360 or IEC 60228

Insulation

Poly Vinyl Chloride (PVC), Heat resistant (HR) PVC, Fire Retardant (FR) PVC, Fire
Retardant Low Smoke (FRLS) PVC, Zero Halogen (LSOH), Thermosetting (XLPE,
Rubber etc.)

Colours

Green/Yellow, Blue, Red, Black, Grey, White, any other colours on request

Sheath
(Multicore)

Poly Vinyl Chloride (PVC), Heat resistant (HR) PVC, Fire Retardant (FR) PVC, Fire
Retardant Low Smoke (FRLS) PVC, Zero Halogen (LSOH)

Comparitive Properties
Feature
Temperature Rating
Requirement of Oxygen
to catch Fire (% in air)
Temperature required to catch Fire
Temp (with 21% in Oxygen)
Visibility during cable burning (%)
Release of Halogen Gas during
burning (% by weight)
Flame Retardancy

HR PVC

FR-PVC

85C

70C

70C

105C

>21

>30

>30

>35

Room Temp.
<20

>250C
<35

>250C
>40

>300C
>80

<20
Good

<20
Very Good

<20
Very Good

ZERO
Excellent

FRLS-PVC

FLEXIBLE & FLAT (RHINOS) 2, 3, 4, 6, 10, 12, 14, 16, 19, 24 & 27
(Details available on request).

ISO

9001

COMPANY
32

ISO-9001 REGISTERED

Note : The number and diameter of conductor strands are for reference only and governed by conductor

C024

DNV-Certification B.V. THE NETHERLANDS

resistance. For other type of cords, wires, ECC, Flat, etc. the diamensions, parameters are available on request.
**Modification which serve to improve our products will be implemented without notice.

LSOH

Cables Constructions
6491x : Copper Conductor, PVC Insulated Unsheathed Wires
Nominal cross
section area
of conductor
2
mm
1.5

2.5

4.0

6.0

10

16
25
35
50
70
95
120
150
185
240
300
400

Number/Nominal
dimeter of wires

Thickness
of Insulation

No/mm
1/1.4
7/0.53
30/0.25
1/1.8
7/0.67
50/0.25
1/2.25
7/0.85
56/0.30
1/2.76
7/1.04
84/0.30
1/3.57
7/1.35
80/0.40
7/170
126/0.40
7/2.14
196/0.40
7/2.58
276/0.40
19/1.78
396/0.40
19/2.14
360/0.50
19/2.52
475/0.50
37/2.03
608/0.50
37/2.25
756/0.50
37/2.52
925/0.50
61/2.25
1221/0.50
61/2.52
61/2.85

mm

Overall
Diameter
Max.
mm

Current
carrying
capacity
Amps

0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.8
1.8
2.0
2.0
2.2
2.2
2.4
2.6

3.2
3.3
3.4
3.9
4.0
4.1
4.4
4.6
4.8
5.0
5.2
5.3
6.4
6.7
6.8
7.8
8.1
9.7
10.2
10.9
11.7
12.8
13.9
14.6
16.0
17.1
18.2
18.8
20.2
20.9
22.5
23.3
24.9
26.6
28.4
29.6
33.2

17.5
17.5
17.5
24
24
24
32
32
32
41
41
41
57
57
57
76
76
101
101
125
125
151
151
192
192
232
232
269
269
300
300
341
341
400
400
458
546

Resistance
per Km
at 20C
Ohms
12.1
12.1
13.3
7.41
7.41
7.98
4.61
4.61
4.95
3.08
3.08
3.3
1.83
1.83
1.91
1.15
1.21
0.727
0.78
0.524
0.554
0.387
0.386
0.268
0.272
0.193
0.206
0.153
0.161
0.124
0.129
0.099
0.106
0.0754
0.0801
0.0601
0.0470

Insulation
resistance
at 70C
M ohm-km
0.011
0.010
0.010
0.010
0.009
0.009
0.0085
0.0077
0.007
0.0070
0.0065
0.006
0.0070
0.0065
0.0056
0.0050
0.0046
0.0050
0.0044
0.0043
0.0038
0.0043
0.0037
0.0035
0.0032
0.0035
0.0032
0.0032
0.0029
0.0032
0.0029
0.0032
0.0029
0.0032
0.0028
0.0030
0.0028

33

AERIAL BUNCHED CABLES


Application:

Outdoor distribution in Rural or residential areas Offers cost effective safer


and reliable cable for reticulation.

Range:

LV Cables with XLPE, PVC or PE insulation MV cables with XLPE


insulation
Standard:

IS 14255, BS 7870-5, BS 625 HD 626,VDE


00276 P 626, IEC 60502 NF C 33-209

Voltage:

600/1000V, 11KV, 22KV

Conductor:

Hard Drawn Aluminium, alluminium alloy or


copper

Insulation:

Specially formulated for exposure to sunlight and outdoor application. LV


XLPE or PE is loaded with carbon black MV cable insulated and screened
cores are PVC sheathed

Max Operating Temp:

XLPE: Max 90oC


PVC or PE: Max 70oC

Construction:

Insulated cores may be bundled together or laid up around high tensile


insulated or bare messenger. If a messenger is provided; as the tension
is taken by it, phase conductors can operate at maximum allowable
conductor temperature.

Minimum Bending Radius: For LV 10 times & MV 15 times cable diameter


Solar Radiation:

ISO

9001

COMPANY
34

1000 W/ sq m

ISO-9001 REGISTERED

C024

DNV-Certification B.V. THE NETHERLANDS

**Modification which serve to improve our products will be implemented without notice.

Cables Constructions
LV Cables
Electrical Parameters

Conductor

Current Rating
In Air @ 30o C
Area (Sq. mm)

Strands

Maximum DC
Resistance @ 20o C

Reactance

Approx
Breaking Load

Amp

/km

/km

KN

16

87

1.91

0.091

2.84

25

107

1.20

0.087

4.17

35

132

0.868

0.085

5.78

50

165

0.641

0.083

8.45

70

19

205

0.443

0.0789

11.32

95

19

250

0.32

0.075

15.30

120

19

290

0.253

0.073

20.00

19

330

0206

0.072

25.00

150
o

Current rating for max cond temp 80 C and wind velocity 1 km/hr

91 Bobbin Stranding Machine

35

KEI RUBBER CABLES


In Keeping with the commpany's commitment to technological advancement, elastomer materials such
as Ethylene Propylene Rubber "EPR", Polychloroprene "PCP", Chloro Sulphonated Polyethylene "CSP"
Nitrile Rubber / PVC Blends, Ethylene Vivyl Acetate "EVA" and Silicone Rubber have been specially
compounded to meet numerous heat oil and fire resisting requirements. In the recent years KEI has also
developed special Elastomeric Fire Survival Cables for power, control and instrumentation wiring.
Elastomeric compounds for insulating and sheathing of cables are formulated to meet the requirement of
BS 6899, IEC 60502 and IEC 60092 other international specification.
GENERAL CONSTRUCTION "Conforming to IS 9968 Part I"
Conductor

Annealed tinned Copper wires Solid "Class 1", Stranded "Class 2" flexible "Class 5"
complying with the requirement of BS 6360/IE 60228

Seperator Tape
Insulation

Suitable Material Seperator Tape may be applied over the conductor.


General Service elastomer compound / Heat Resisting elastomer compound /
Silicone rubber as per IEC 60092 "351", BS-7655, VDE-0207Pt.-20

Core Identification

Coloured insulation, Nos. Polyester tape, Coloured proofed tape, Nos. printing.

Fillers

Natural or synthetic fibers or elastomer suitable for the operating temperature and
compatible with the insulating material.

Sheath

General Service elastomeric compound / Heavy Duty elastomeric compound as


per IEC 60092 "359", BS-7655, VDE 0207Pt.-21

Working Temperature of Commonly Used Elastomeric Insulating and Sheathing Material


MATERIAL

Natural Rubber (VIR and TRS)


Ethylene Propylene Rubber (EPR)
Polychloroprene (PCP)
Chlorosupphonated Polyethylene (CSP)
Silicone Rubber
HR Nautral Ruber (HR VIR)
Styrene Butadience Rubber
Butyl Rubber

Max. Cond. Temp.


for continuous
operation

Max. Cond.
Temp. for short
circuit

Min. Working
Temp.

Deg C.

Deg C.

Deg C.

60
90
70
90
150 / 180
75
60
85

200
250
200
200
350
200
200
220

-55
-50
-40
-35
-55
-55
-55
-50

Control Room Impulse Testing


& Heat Cycle Test etc.

ISO

9001

COMPANY
36

ISO-9001 REGISTERED

C024

DNV-Certification B.V. THE NETHERLANDS

**Modification which serve to improve our products will be implemented without notice.

Cables Constructions
Elastomeric Cables Range

Application

Cables up to 11 KV

Machine Trailling, Mining, Power

Flexible Trailing Cables

Reeling unreeling, Trailing, Festooning, Mobile Machines, Cranes, Coal Handling and
Conveyors

Mining Cables

FT or Pliable Armoured or Landline type as per IS 14494, NCB, SABS specs for UG, Open cast,
Coal or other mines and mining machines

Thermal Power Plants

For coal handling plants, flexible power and control application

Cables for steel plants

Flexible and high temp withstanding cables for furnace, melting shops, material handling

Wind energy

Flexible cables for power and control for Wind Mill generator connection

Fire Survival Cables

Fire Survival for 3 Hrs or 20 Min

Ship wiring

As per IEC specs and Naval specs DGS of DEFSTAN, NES

OFFSHORE and ONSHORE

For platforms and Ring as per IEC, BS and NEK Specs

Shore Supply & Generator Cables

For charging of ship batteries and supply from mobile generators

Motor Coil Leads

Elastomeric and Silicon as per IS, BS, or OEM Specs

High Temp Cables

Silicon insulated, glass fiber braided or unbraided

Pump Cables

For Water, submersible and sewerage pumps

Cables for Railway

Coach wiring, Metro railway

Wire

HFFR Low toxic emission under fire

Panel Wiring

For flexible, high power high temp zone, polluted or moist atmospheres

Battery Cables

For High current and long life

Low Temperature installations

Suitable for subzero temp installations and operations

Misc. Applications

outdoor high mast lighting, site power supply, white goods, oil or chemical resistant

Type

Power and Control cables up to 61 Crores Instrumentation Pairs 30 pairs, triads, quad
Wires, flat cables

Voltage Grades

11KV, 6.6KV, 3.3KV, 1.1KV, 750V, 250V, 110V, 60V

Conductor Range

0.5 to 630 Sq. mm

Polymers Processed
COMPOUNDS

EPR, EPDM, PCP, CSP, CPE, SILICONE, EVA HALOGEN FREE AND FIRE RESISTANT
NON TOXIC COMPOUNDS

Braiding Offered

ATC, GI wire braid, Synthetics or Textile Yarn, Glass Fiber

Armouring

Pliable armour or steel/copper wires/Stainless steel

Mica Taping Machine

Braiding Machine

37

CABLES FOR INSTRUMENTATION


KEI manufactures a wide variety of cables suitable for process instrumentation, which plays a vital role in
measurement, supervision and control of the process. Introduction of microprocessor based /
computerized instrumentation has demanded stringent quality requirements along with special electrical
parameters for instrumentation cables.
The cables used for instrumentation are designed and manufactured very meticulously. KEI maintains
high quality standards and follow & stringent in-process quality control during manufacturing of
instrumentation cables, meeting the design parameters of the customer
Conductor

0.5 Sq. mm to 2.5 Sq mm of solid/stranded Tinned/untinned copper


conductors.

Insulation

PVC/Polyethylene/XLPE/LSOH as per requirement.

Elements / Core:

Pair/Triad/Quad, colour coded / number printed.

Screening

Aluminium Polyester screen over all (collective) screen (OAS),


individual screen (IS), or both IS & OAS with ATC drain wire. Wire
braiding can also be given as per customer requirement.

Element Laying

Concentric formation or unit & group formation as per requirement.

Armouring

Unarmoured / Galvanised steel wire / Flat wire armoured.

Sheathing

PVC, FR PVC, FRLS, LSOH as per requirement.

Specification

EIL-6-52-46. Rev.05, BS: 5308 Part 1 & Part 2, BSC 143-0.75


(24/0.2 mm) OAS, IEC 60092-375, 376, BS EN 50288, VDE 0815,
VG 95218, NEK 606 and customers Specifications.)

French Machine for


Pairing & Screening

ISO

9001

COMPANY
38

ISO-9001 REGISTERED

C024

DNV-Certification B.V. THE NETHERLANDS

**Modification which serve to improve our products will be implemented without notice.

Cables Constructions
Typical Instrumentation Cable Constructions

OUTER SHEATH
1. PVC
2. FR/FRLS PVC
3. Halogen Free (LSOH)

ARMOUR
Galvanised Steel
Wire / Flat Wire

SCREENING (INDIVIDUAL & OVERALL)


1. Copper Wire Braid or
2. Al-Polyester tape with copper drain wire. (Individual & Overall)

CABLING ELEMENT

PAIR

TRIAD

UNIT

INNER SHEATH
1. PVC
2. FR/FRLS PVC
3. Halogen Free (LSOH)

INSULATION

COPPER CONDUCTOR

1. PVC
2. Polyethylene
3. XLPE
4. LSOH

1. Bare (ABC)
2. Tinned (ATC)
3. Solid
4. Stranded

Stranded copper
conductors class 2

Solid copper
conductors class 1

Insulation

Flexible copper
conductors
class 5
Insulation

Insulation
Triples in Metal Foil

Aluminium laminated
synthetic foil in contact
with a drain wire
Inner sheath

Aluminium
laminated
synthetic foil
in contact with
a drain wire

Inner sheath

Galvanized
steel wire
braid

Galvanized round
steel wire armour
Halogen-free
fire retardant outer sheath

Outer sheath
Outer sheath

39

THERMOCOUPLE EXTENSION / COMPENSATING


CABLES
Thermocouple extension and compensating cables are designed for interconnercion between
thermocouple probes and control instrumentation. They are generally available in the following types:
Type (1)
Unarmoured cables with conductors insulated with PVC and twisted together in pairs, sheathed overall
with PVC.
Type (2)
Armoured cables with conductors insulated with PVC and twisted together in pairs, PVC bedding,
Galvanised steel wire armour and sheathed overall with PVC.
All of the above types of cables can be supplied unscreened or screened (individually, collectively or both)
with an Aluminium Polyster tape screen incorporating tinned copper drain wire.
The construction is similar to paired instrumentation cable but the conductor material is different.
Thermocouple are used in processes to sense temperature and is connected to the pyrometers for
indication and control. The thermocouple and pyrometers are electrically connected by thermocouple
extension/compensating cables. The conductors used for these cables are required to have similar
thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature.
Range of Instrumentation Cables:

ISO

9001

COMPANY
40

Standard

ANSI MC 96.1, BS-1843, IEC 60584-3, ENI

Conductor

Solid type as per type & mentioned in the table

Insulation

PVC/Polyethylene/XLPE/LOSH as per requirement.

Elements

Pairs colour coded/number printed.

Screen

Aluminium Polyester tape screen with Copper drain wire or alternately with
Tinned Copper wire braiding. Individual element or overall screening as
specified.

Armouring

Galvanised steel round wire / Flat wire.

Sheathing

PVC, FR PVC, FRLS, LSOH as per requirement.

ISO-9001 REGISTERED

C024

DNV-Certification B.V. THE NETHERLANDS

**Modification which serve to improve our products will be implemented without notice.

SINGLE / MULTI CORE FIRE RESISTANT CABLES

Conductor :
Plain annealed copper stranded (class 2)
conductor for ease of handling.
Tape Insulation :
Mica fire resistant tape.
Insulation:
90C cross-linked insulation.
Bedding :
Extruded LSOH bedding compound.
Armour :
Single layer of galvanised steel wires.
Sheath :
Robut LSOH sheath, Colour Black.
Other Colours as per specification of the Customer

Core Identification :
Red Black
Red Yellow Blue
Black Red Yellow Blue
7- 37 Cores white with Printed numbers
Other Core colors available as per customer specification
Cable Characteristics

ISO

9001

COMPANY

TEMPERATURE

Range 25 to + 900C

BENDING RADIUS

Circular conductor r=6D Shaped conductor r=8D

MECHANICAL IMPACT

Very Good

FIRE PERFORMANCE

BS 4066-1, BS4066-3

FLEXIBILITY

Rigid

HALOGEN FREE

BS6425-1

LOW SMOKE

Emissions BS 7622

FIRE RESISTANT

BS 6387

ISO-9001 REGISTERED

C024

DNV-Certification B.V. THE NETHERLANDS

**Modification which serve to improve our products will be implemented without notice.

41

Cables Constructions
Single Core Fire Resistant Cables Low Voltage - 450/750 Volts
Nominal
cross
sectional
area
mm
+1
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Mean
overall
diameter

Approximate
cable
weight

mm

kg/km

3.7
3.9
4.7
5.3
5.9
7.3
8.5
11.3
12.5
14.5
16.5
18.5
20.5
22.5
25
28
31
35
38.5
42.5

20
26
38
54
75
122
185
300
390
525
730
1000
1230
1520
1890
2440
3045
3870
4930
6280

Maximum
conductor
resistance
at 20C
ohms/km (1
18.1
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047
0.0366
0.0283

Short
circuit
rating
sec) KA

Current
rating DC
or single
phase AC
Amps

0.1
0.15
0.25
0.4
0.6
1.0
1.6
2.5
3.5
5.0
7.0
9.5
12
15
18
24
30
40
50
63

17
22
30
40
51
71
95
126
156
189
240
290
336
375
426
500
573
683
783
900

Current
rating
Three
phase AC
Amps

Volt
drop
DC

Volt drop
Single
phase AC

Volt drop
Three
phase AC

mV/A/m

mV/A/m

mV/A/m

46
31
19
12
7.9
4.7
2.9
1.9
1.35
1.05
0.75
0.58
0.48
0.43
0.37
0.33
0.31
0.29
0.28
0.27

40
27
16
10
6.8
4.0
2.5
1.65
1.15
0.9
0.65
0.5
0.42
0.37
0.32
0.29
0.27
0.25
0.24
0.23

15
19
26
35
45
63
85
111
138
168
214
259
299
328
370
433
493
584
666
764

46
31
19
12
7.9
4.7
2.9
1.85
1.35
0.99
0.68
0.49
0.39
0.32
0.25
0.19
0.155
0.12
0.093
0.072

Current rating
DC or Single
phase AC
Clipped direct
Amps

Current
rating DC or
Single phase
AC Free Air
Amps

Volt drop
DC

Volt drop
Single
phase AC

mV/A/m

mV/A/m

18
27
36
49
62
85
110
146
180
219
279
338
392
451
515
637
698
787

21
29
39
52
66
90
115
152
188
228
291
354
410
472
539
636
732
847

47
31
19
12
7.9
4.7
2.9
1.85
1.35
0.98
0.67
0.49
0.39
0.31
0.25
0.195
0.155
0.12

47
31
19
12
7.9
4.7
2.9
1.9
1.35
1.0
0.69
0.52
0.42
0.35
0.29
0.24
0.21
0.19

Multi Core Fire Resistant Cables Low Voltage - 600/1000 Volts


Nominal
cross
sectional
area
mm

Approximate
overall
diameter

Approximate
diameter
under
armour

mm

mm

Nominal
diameter
of armour
wires
mm

Approximate
cable
weight
kg/km

Maximum
conductor
resistance
at 20C
ohms/km

Two core
+1
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

42

12.2
12.9
14.1
15.2
16.4
18.6
21.4
22.0
24.8
28.0
30.7
35.3
36.6
39.3
44.2
48.0
51.8
55.9

7.8
8.3
9.6
10.6
12.0
14.0
15.9
16.3
18.2
21.2
23.7
27.3
28.4
30.9
34.4
38.0
41.6
45.3

0.9
0.9
0.9
0.9
0.9
0.9
0.9
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5

280
310
380
450
530
630
920
1200
1600
2000
2400
3300
3800
4400
5700
7200
8300
10500

18.1
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047

Single / Multi Core Fire Resistant Cables


Three Core
Nominal
diameter
of armour
wires
mm

Approximate
cable
weight

mm

Approximate
diameter
under
armour
mm

12.7
13.4
14.8
16.1
17.4
20.3
22.8
27.4
29.2
33.0
37.0
40.6
43.8
48.0
52.0
57.1
63.0
69.5

8.3
8.8
10.2
11.5
12.8
14.8
17.1
20.8
22.4
26.2
30.0
32.4
35.4
38.4
42.2
46.9
52.6
58.7

0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5

310
340
430
510
620
930
1210
1800
2100
2600
3400
4500
5500
6900
8200
10200
12200
15000

18.1
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

Nominal
cross
sectional
area
mm

Approximate
overall
diameter

Nominal
diameter
of armour
wires
mm

Approximate
cable
weight

mm

Approximate
diameter
under
armour
mm

kg/km

Maximum
conductor
resistance
at 200C
ohms/km

+1
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

13.5
14.3
16.0
17.3
19.6
21.8
24.6
29.1
32.2
35.0
40.2
44.0
48.4
52.5
57.1
62.7
69.6
78.0

9.1
9.7
11.4
12.7
14.1
16.3
18.9
22.5
25.4
28.0
32.0
35.6
38.8
42.7
46.9
52.3
58.8
65.3

0.9
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15

350
390
490
590
830
1040
1370
2100
2500
3200
4500
5600
7200
8500
10300
12800
15600
20400

18.1
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470

Nominal
cross
sectional
area
mm

Approximate
overall
diameter

+1
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400

kg/km

Maximum
conductor
resistance
at 200C
ohms/km

Short
circuit rating
(1 sec) of
Conductor
KA

Current
rating Three
phase AC
Clipped direct
Amps

Current
ratingThree
Phase
AC Free Air
Amps

0.14
0.20
0.35
0.57
0.86
1.4
2.2
3.6
5.0
7.1
10.0
13.6
17.2
21.4
26.5
34.3
42.9
57.2

17
23
31
42
53
73
94
124
154
187
238
389
335
386
441
520
599
673

18
25
33
44
56
78
99
131
162
197
251
304
353
406
463
546
628
728

40
27
16
10
6.8
4.0
2.5
1.65
1.15
0.87
0.60
0.45
0.37
0.30
0.26
0.21
0.185
0.165

Current
rating Three
phase AC
Clipped direct
Amps

Current
ratingThree
Phase
AC Free Air
Amps

Volt drop
Three
phase
AC
mV/A/m

Volt drop
Three
phase
AC
mV/A/m

Four core
Short
circuit rating
(1 sec) of
Conductor
KA
0.14
0.20
0.35
0.57
0.86
1.4
2.2
3.6
5.0
7.1
10.0
13.6
17.2
21.4
26.5
34.3
42.9
57.2

17
23
31
42
53
73
94
124
154
187
238
289
335
386
441
520
599
673

18
25
33
44
56
78
99
131
162
197
251
304
353
406
463
546
628
728

40
27
16
10
6.8
4.0
2.5
1.65
1.15
0.87
0.60
0.45
0.37
0.30
0.26
0.21
0.185
0.165

Circular conductor 1.0-16mm, Shaped conductor >= 25mm.

43

Cables Constructions
Nominal
cross
sectional
area
mm

Approximate
overall
diameter
mm

Approximate
diameter
under
armour
mm

Nominal
diameter
of armour
wires
mm

Approximate
cable
weight
kg/km

Maximum
conductor
resistance
at 20C
ohms/km

Current rating
DC or Single
phase AC
Clipped direct
Amps

Current rating
Volt
Volt drop
DC or Single
drop
Single
phase AC
DC
phase AC
Free Air
Amps
mV/A/m mV/A/m

Seven core
+1
1.5
2.5
4.0

15.6
16.4
18.3
20.8

11.0
11.8
13.7
15.3

0.9
0.9
0.9
1.25

450
500
640
910

18.1
12.1
7.41
4.61

18
27
36
49

*
*
*
*

21
29
39
52

*
*
*
*

47
31
19
12

47
31
19
12

20.1
21.2
24.0
27.3

14.6
15.7
18.3
20.9

1.25
1.25
1.25
1.6

750
850
1090
1550

18.1
12.1
7.41
4.61

18
27
36
49

*
*
*
*

21
29
39
52

*
*
*
*

47
31
19
12

47
31
19
12

22.8
24.2
28.6

17.1
18.5
22.0

1.25
1.25
1.6

970
1120
1650

18.1
12.1
7.41

18 *
27 *
36 *

21 *
29 *
39 *

47
31
19

47
31
19

21.1
22.8
26.6

1.6
1.6
1.6

1430
1650
2150

18.1
12.1
7.41

18 *
27 *
36 *

21 *
29 *
39 *

47
31
19

47
31
19

23.7
25.6
29.9

1.6
1.6
1.6

1700
2000
2650

18.1
12.1
7.41

18 *
27 *
36 *

21 *
29 *
39 *

47
31
19

47
31
19

Twelve core
+1
1.5
2.5
4.0

Nineteen core
+1
1.5
2.5

Twenty-seven core
+1
1.5
2.5

27.7
29.4
33.4

Thirty-seven core
+1
1.5
2.5

30.6
32.2
36.7

Circular conductor 1.0-16mm, Shaped conductor >= 25mm. Installation methods for current rating in accordance with BS7671/IEE Wiring
Regulations *.
The tabulated rating is as a two core cable and may be used where the number of cores carrying current does not exceed the square root of the
total number of cores. +Size not included in BS7846

Installation methods for current rating "Enclosed in conduit on a wall or in trunking" in accordance with BS7671/EE Wiring Regulations. The tabulated
ratings are based upon a 30C ambient temperature and 90 C operating temperature. For other ambient temperatures or where several circuits are
grouped together, the following rating factor should be applied.

44

Temperature rating factors


Ambient Temperature C
Rating factor

25
1.02

30
1.00

35
0.96

40
0.91

45
0.87

50
0.82

55
0.76

60
0.71

Correction factors for groupings


Number of circuits
Rating factor

2
0.80

3
0.70

4
0.65

5
0.60

6
0.57

7
0.54

8
0.52

9
0.50

KEI INDUSTRIES LIMITED


Registered and Corporate Office
D-90, Okhla Industrial Area Phase-1, New Delhi-110020.
Tel: (011)- 26818840/8642/0242 Fax: 26817225, 26811959.
E-mail: info@kei-ind.com, delhi@kei-ind.com, Website: www.kei-ind.com
Unit-1
SP-919/920/922 RIICO Industrial Area, Ph-III, Bhiwadi Distt. Alwar-301019, Rajasthan.
Tel: (01493)-220106/221731. Fax: 221731.
E-mail: bhiwadi@kei-ind.com
Unit-2
99/2/7, Madhuban Industrial Estate, Rakholi, Silvassa-396230,
D&N H. Tel.: +91-0260-2644404/2630944.
Fax: +91-0260-2645896. E-mail: silvassa@kei-ind.com
Unit-3 (EOU)
A 280/281/282/283 Chopanki Industrial Area (Bhiwadi) Distt. Alwar, Rajasthan-301019.
Tel.: 01493-260202/06. Fax: 01493-260204
E-mail: chopanki@kei-ind.com
Marketing Office (Mumbai)
101/102, Vastu Shilp, Vastu Enclave, Andheri Pump House, Andheri (East), Mumbai-400093.
Tel: 022-28239673, 28375642. Fax: 022-28258277.
E-mail: mumbai@kei-ind.com
Jaipur Office
7 Kailash Path, Suraj Nagar (W) Civil lines, Jaipur-302006
Tel: 0141-5179279, 09829036095 Fax: 0141-2221707
E-mail: jaipur@kei-ind.com
Pune Office
1st Floor-5, Vighnhar Chambers, Opp.Telephone Exchange Office, Karve Road, Pune - 411 004.
Tel: 9822048426 Fax: 020-25450345, 66407241
E-mail: pune@kei-ind.com
Baroda Office
803, Siddharth Complex, Near Hotel Express, R. C. Dutt Road, Baroda-390007.
Tel: 0265-6539719, 2341831 Fax: 0265-2334161.
E-mail: baroda@kei-ind.com .
Bangalore Office
303, 3rd Floor, President Chamber, Plot No. 8, Richmond Road, Bangalore-560025.
Telefax: 080-22111187. E-mail: bangalore@kei-ind.com
Chennai Office
F-1, Sir Usman Court, New No. 63 (Old No. 27), Eldams Road, Teynampet, Chennai-600018.
Tel: 044-42009120. Telefax: 044-42009130.
E-mail: chennai@kei-ind.com
Hyderabad Office
Plot No. 76, H.No.: 3-14-52/1, Shubodaya Colony, Near Little Chums School,
Mansoorabad,Vanasthalipuram, Hyderabad-500070.
Tel : (040) 20064358, 099855 22558, 099855 77886 Fax : 040-24024260
E-mail: hyderabad@kei-ind.com
Kolkata Office
33, Dr.Sundari Mohan Avenue, 1st Floor, Kolkata - 700 014.
Tel:(033) 22866696, 9831806270 Telefax: :(033) 22866697
E-mail: kolkata@kei-ind.com
Chandigarh Office
Flat no. 302, GH-26, Mansa Devi Complex, Sector 5, Panchkula, Punjab
Tel: 9876867788 Email: chandigarh@kei-ind.com
Bhopal Office
E/87, Minal Residency, Phase 1, J. K. Road, Govindpura, Bhopal (MP)-462023
Tel: 9752531145
E-mail: bhopal@kei-ind.com
Bhubaneswar Office:
C/21, Palashpalli, Near N.C.C. Office, Bhubaneswar- 751012 Tel: 9238396638
Jamshedpur Office:
Flat C1/3, Sabitri Tower, 1st floor, Ulyan,Kadma. Jamshedpur-831005. Jharkhand
Tel: 09470391385
Guwahati Office:
H/N 13, Pub Sarania Road, Guwahati -03
Tel: 09706026245
Chhatisgarh Office:
Soubhagya, 72/10, Nehru Nagar (West), Bhilai 490020 Chhattisgarh
Tel: 096300-19494
Kanpur Office:
8/6, F.M. Colony, Civil Lines Kanpur-208001
Tel: 09839081711 Email: kanpur@kei-ind.com
Goa Office:
F-1, Shetye Apts, Antilpeth, Bicholim, Goa - 403 504.
Tel:9765394685
Nagpur Office:
103, Misal Layout, Nagpur - 440014.
Tel: 9822473774
Cochin Office:
36 / 2853, Nagawallil, Balan Menon road, Kaloor, Cochin - 682 017. Kerala
Tel: 09846004702.
OVERSEAS OFFICE (Dubai)
Post Box No. 261739, Jebel Ali Free Zone, Dubai, U.A.E. Tel: +971-(050) 2112013.
Fax: +97143689337. E-mail: dubai@kei-ind.com

Вам также может понравиться