WIRING DIAGRAMS
Video adapter
Power supply
Entrance panel
LIVING ROOM
349320
=
=5
P =
M =
ON
ROOM 1
349321
=
=4
P =
M =
N
BUS
ROOM 2
OFF
349320
=
=2
P =
M =
N
OFF
BUS
Kitchen
349321
=
=3
P =
M =
N
BUS
Reception room
OFF
349320
=
=1
P =
M =
N
OFF
BUS
BUS
230 Vac
TR
BUS
TK
P
N
T
S
PRI
2 PL S+ S-
NF
CEBEC
IP30
PS
BUS 2 1
P T
346230
230 Vac
BUS
PL
=1
=
T =
M =
JMP =
JMP =
P
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
343001
=
=
=
=1
=
=9
BUS
PI
Additional
door lock
346000
346830
S+ S-
S1 Door lock
PS
Max. 5 handsets
Max. 200 metres between the entrance panel and the last handset with cable, item 336904
Note 1: We recommend that the video handsets are configured using the software supplied with the product
Note 2: When a call is received, only the video handset configured with N=1 comes on
WIRING DIAGRAMS
Power supply
Outdoor
camera
Entrance panel
LIVING ROOM
ON
344163
=
=1
P =
M =
N
=
=4
P =
M =
N
BUS
ROOM 2
ROOM 1
349321
OFF
349320
=
=2
P =
M =
N
OFF
BUS
Kitchen
349321
=
=3
P =
M =
N
BUS
Reception room
OFF
349320
=
=5
P =
M =
N
OFF
BUS
BUS
342991
F441
=
=
=
N
=1
T =
S =9
OUT1
BUS
PL
S+ S-
OUT 2
O UT3
346000
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN
IN 1
S1 Door lock
I N2
IN 3
IN 4
NF
CEBEC
IP30
BUS 2 1
SC S
230 Vac
PS
391670
P
N
Z
M
A
PL
=
=1
=
=
=
=
=
391670
P
N
Z
M
A
PL
=
=2
=
=
=
=
=
Max. 5 handsets
Max. 200 metres between the entrance panel and the last handset with cable, item 336904
NOTE 1: We recommend that the video handsets are configured using the software supplied with the product
NOTE 2: The answering machine function is available only using the 344163 video handset, and can only be activated on 1 video
handset (the one configured with N=1)
NotE 3: When a call is received, only the video handset configured with N=1 comes on
WIRING DIAGRAMS
Video Polyx
Audio Polyx
Entrance panel
=
=
=1
N
=8
=
MOD
=
P
ON
344832
BUS
APARTMENT 18
=
=
=1
N
=6
=
MOD
=
344832
346841
APARTMENT 16
ON
BUS
=
=
=
N
=2
=
M
=
ON
APARTMENT 2
344192
346841
BUS
=
=
=
N
=1
=
M
=
ON
APARTMENT 1
BUS 344082
346841
351200
346000
= 352100
=
=
N
=1
S =
T = 352100
M =
J1 =
JMP
P
BUS BUS
TK PI
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
PS
S1
PS
BUS 2 1
346830
230 Vac
Move the micro-switch on the back of the last audio or video handsets of the line to the ON position
WIRING DIAGRAMS
Audio Polyx
To the handsets
To the handsets
F441
346000
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
F441
346000
SCS
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
SCS
BUS 2 1
230 Vac
PRI
NF
CEBEC
IP30
BUS 2 1
230 Vac
PE at the
bottom of
the stairs
=3
=9
MOD = 5
M
S1
346851
346851
PS
OFF
ON
OF F
351200
ON
==1
MOD = 5
M
ON
ON
ON
OFF
346851
=
P
=2
=
N
= 1 352000
S =
T =
M =
JMP
352000
JMP
34685 1
ON
346851
==1
MOD = -
346000
BUS
TK
BUS
PI
ON
PRI
ON
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
OF F
NF
CEBEC
IP30
PS
346851
BUS 2 1
346830
230 Vac
346000
BUS BUS
TK
PI
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
PS
346830
BUS 2 1
230 Vac
352400
=
=
=
N
=
S =
T =
M =
JMP
JMP
P
351100
39 risers
for each riser 1 EP at the bottom of the stairs and 64 handsets or 100 apartment interfaces
352500
Move the micro-switch on the back of the last system expansion module of the line to the ON position
Configure the EP at the bottom of the stair by missing one configuration step (ex. P = 2, P = 4, P = 6...)
WIRING DIAGRAMS
Outdoor camera
Indoor camera
Video display Axolute Eteris
Apartment
interface
Audio/video node
Power supply
344163
ON
Apartment extension 5
=
=5
P =1
M =
N
344163
BUS
ON
=
=2
P =1
M =
N
349340
BUS
=
=4
P =1
M =
N
OFF
OK
344163
BUS
OFF
=
=1
P =1
M =
N
344163
BUS
=
=3
P =1
M =
N
OFF
BUS
F441
OUT1
OUT 2
O UT3
346000
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN 1
I N2
IN 3
IN 4
NF
CEBEC
IP30
BUS 2 1
SC S
230 Vac
391661
P
346850
N
Z
M
A
PL
OFF
OUT
=
=5
M =3
N
IN
ON
ON
BUS
PL
=
=1
N =
T =
S =9
P
S+ S-
OFF
Door lock
PS
342991
Building
riser
391670
P
N
Z
M
A
PL
=
=3
=
=
=
=
=
=
=2
=
=
=
=
=
WIRING DIAGRAMS
Common entrance
panel
Apartment interface
Audio/video node
Power supply
SMALL HOUSE 35
SMALL HOUSE 99
346850
346850
=3
=5
M =3
=9
=9
M =3
OFF
OUT
IN
ON
OUT
ON
ON
BUS
OFF
BUS
SMALL HOUSE 1
SMALL HOUSE 26
346850
OUT
IN
=2
N
=6
M =3
OFF
OUT
ON
ON
IN
ON
OFF
BUS
OFF
BUS
Door lock
F441
346000
346260
=
=
T =
M =
JMP
JMP
P
TMP PL
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
RC
NF
CEBEC
IP30
SCS
SCS
BUS 2 1
NC NO/S+ S
230 Vac
max. 50 m
ON
346850
=
N
=1
M =3
OFF
ON
IN
OFF
ON
BUS
=
=
S =
P
349140
In alternative to the door lock actuator item 346260 it is also possible to use the 2 DIN module actuator,
item 346230, appropriately configured
DESCRIPTION
351000
352000
344704
344242
346040
346200
336842
L
PE
PE/S
PS
S1-S2-S3
WARNING
APARTMENT 2
=
N
=2
=
P
=
=
MOD
=
344704
(BUS) to other
Handsets
3
2
1
APARTMENT 9
BUS
(BUS) to other
Handsets
344242
=
=9
=
N
P
BUS
APARTMENT 1
N
P
=
=1
=
344242
APARTMENT 8
344704
=
=8
=
P
=
=
MOD
=
N
BUS
3
2
1
BUS
B
B
351000
351000
=
=2
=
N
=8
S = 352000
T =
M =
JMP
P
=
P
=1
=
N
=1
S = 352000
T =
M =
JMP
S2
PE/S
PL
S3
PL
PE/S
230 Vac
336842
To other Entrance Panels
(max. 4 common EP+local)
346040
PRI
12V
336842
BUS
346040
PRI 110 - 240 V 50 - 60 Hz 370 mA - 225 mA
BUS 26.0 V 600 mA
BUS
230V
351000
=
P
=
=
N
=1
S = 352000
T =
M =
JMP
346200
PRI
BUS
S1
PE
PS
5
1
6
2
7
3
8
4
230 Vac
230 Vac
NC
NO
DESCRIPTION
342702
342704
S1
344704
344082
344242
346000
346200
PS
TR
L
WARNING
always OFF.
PE0
PE1
PE2
--
PE8
APARTMENT 15
=
=
=
P
=
=
M
=
N
1
5
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
BUS
344082
100
64
50
38
30
22
18
14
10
66
66
56
46
36
26
26
16
16
BUS
apartment 3
344242
=
=3
P =
N
APARTMENT 2
344704
344704
=
=2
=
P
=
=
MOD
=
N
BUS
3
2
1
OFF
=
=2
=
P
=
=
MOD
=
N
3
2
1
OFF
APARTMENT 1
344242
=
=1
P =
N
BUS
346000
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
MAX 9 PE
346200
NF
CEBEC
IP30
BU S
PE/M
BUS
PL
S+ S-
S1
T
PS S
5
1
6
2
7
3
8
4
230 Vac
=
=
=
=1
=
=
230 Vac
NC
TR
NO
B
342702
342704
WARNING
ITEM
DESCRIPTION
351000
352100
342702
342704
344704
346000
346200
L
PE/M
PE/S
PS
S1 - S2 - S3
APARTMENT 2
=
=2
=
P
=
=
MOD
=
APARTMENT 11
=1
=1
=
P
=
=
MOD
=
3
2
1
344704
3
2
1
344704
BUS
BUS
APARTMENT 1
=
=1
=
P
=
=
MOD
=
APARTMENT 9
=
=9
=
P
=
=
MOD
=
3
2
1
344704
BUS
3
2
1
344704
BUS
N
T
S
342702
PE/M
BUS PL S+ S-
B
S2
PS
342702
342704
B
P
N
352100
S
T
M
J1
=
=
=
=
=
=
=
=
S3
PS
342704
346200
PRI
PE/S
346000
351000
BUS PL S+ S-
=
=
=
N
=
T =
S =
P
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
BUS 2 1
S1
PS
230 Vac
5
1
6
2
7
3
8
4
NC
230V a. c.
NO
DESCRIPTION
342971
S1
344704
346000
PS
WARNING
PE0
PE1
PE2
--
PE8
9
9
9
9
9
DEVICE 5
3
3
2
3
2
3
1
2
1
2
1
1
Intercom with
handset 3
Intercom with
handset 2
Intercom with
handset 1
Intercom with
handset 4
Intercom with
handset 5
Intercom with
handset 2
Intercom with
1
1 handset 1
Intercom with
handset 4
=_
=5
=
P
=
=1
MOD
=1
N
3
2
1
344704
=_
=3
=
P
=
=1
MOD
=1
DEVICE 4
Intercom with
handset 3
Intercom with
handset 5
Intercom with
1
1 handset 1
Intercom with
handset 4
DEVICE 2
=_
=4
=
P
=
=1
MOD
=1
N
3
2
1
344704
BUS
BUS
3
3
2
3
2
3
1
2
1
2
DEVICE 3
3
3
2
3
2
3
1
2
1
2
Intercom with
handset 3
Intercom with
handset 2
Intercom with
1
1 handset 1
Intercom with
handset 5
3
3
2
3
2
3
1
2
1
2
3
2
1
344704
=_
=2
=
P
=
=1
MOD
=1
N
BUS
3
2
1
344704
BUS
DEVICE 1
3
3
2
3
2
3
1
2
1
2
1
1
Intercom with
handset 3
Intercom with
handset 2
Intercom with
handset 5
Intercom with
handset 4
=_
=1
=
P
=
=1
MOD
=1
N
346000
3
2
1
344704
BUS
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
BUS
230 Vac
MAX 9 PE
BUS PL S+ S-
P
N
T
S
=
=
=
=
=
=
342971
A
S1
PS
PEO
WARNING
ITEM
DESCRIPTION
351100
344082
346000
PE/S
PL1
S1
APARTMENT 1
Intercom inside apartment
Intercom between
apartments
Relay control configured
with MOD=9 and P+1
Relay control configured
with MOD=5 and P+1
APARTMENT 2
344082
=
N
=1
=
P
=
=
MOD
=1
344082
344082
=
N
=2
=
P
=
BUS
=
MOD
=1
BUS
344082
344082
=
N
=1
=
P
=
=
MOD
=1
344082
=
N
=2
=
P
=
BUS MOD =
=1
BUS
=
N
=1
=
P
=
=
MOD
=1
=
N
=2
=
P
=
BUS
=
MOD
=1
BUS
346000
PE/S
=
=
=
N
=
S =
T =
M =
JMP
JMP
P
1 351100
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
S1
PS
NF
CEBEC
IP30
BUS 2 1
230 Vac
MOD = 5
=
=
=
N/P
=1
T =
346200
5
1
6
2
7
3
8
4
NC
230V a.c.
NO
DESCRIPTION
351000
352100
344704
346000
346200
L
PE/S
PL
S1
WARNING
PE0
1
PE1
1
PE2
1
--
1
PE8
1
N = first apartment that can be called by the EP
APARTMENT 11
=1
=1
=
P
=
=
MOD
=
344704
APARTMENT 5
3
3 Intercom with apartment 3
3
2
2 Intercom with apartment 2
2
1
1 Intercom with apartment 1
1
=
N
=5
=
P
=
=1
MOD
=1
344704
APARTMENT 4
BUS
APARTMENT 3
=
=3
=
P
=
=1
MOD
=1
344704
C
BUS
344704
352100
S
T
M
J1
344704
3
2
1
346200
=
=2
=
P
=
=1
MOD
=1
N
346000
BUS
=
=
=
=
=
=
=
=
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
3
2
1
BUS
3
2
1
PRI
PE/S
344704
APARTMENT 2
3 Intercom with apartment 3
3
3
2
2
2 Intercom with apartment 5
1
1
1 Intercom with apartment 1
351000
=
=4
=
P
=
=1
MOD
=1
N
BUS
3
2
1
APARTMENT 1
=
N
=1
=
P
=
=1
MOD
=1
BUS
3
2
1
3
2
1
NF
CEBEC
IP30
BUS
230 Vac
5
1
6
2
7
3
8
4
230 Vac
NC
NO
S1
PS
ITEM
DESCRIPTION
336842
344704
346000
346040
346230
346991
346992
PS
S1
Transformer
SWING audio handset
Power supply
Power supply
Door lock actuator
Universal speaker module
Pushbutton expander
Door lock release pushbutton
Electrical door lock
WARNING
SWITCHED OFF. Also every time the configuration is
modified the power supply to the system must be
switchedoff and on again, waiting about 1 minute.
(BUS)
to other
Handsets
APARTMENT N
PRI
PRI
BUS
=
N
=N
P =
3
2
1
344704
344704
BUS
BUS
=
N
=N
P =
3
2
1
346040
PRI 110 - 240 V 50 - 60 Hz 370 mA - 225 mA
BUS 26.0 V 600 mA
BUS
346040
BUS
3
2
1
344704
BUS
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
346000
BUS 2 1
230 Vac
346991
P N S
BUS
Possible systems
WITH 346000
WITH 346040
56
56
346991
8 7 6 5 4 3 2 1
(BUS)
to other Entrance Panels
(max. 4 with 346040)
maximum No. of
call pushbutton
maximum No. of
expanders
=
N
=N
P =
PE0
1
PE1
1
PE2
1
--
1
N = first apartment that can be called by the EP
C
N
N+1
C
n8
N+7
max 3 m
C
N+8
N+9
12 Vac
18 V A
12V
336842
230V
N +15
336842
2 1 C
IN
230 Vac
OUT
346992
346000
PS
BUS
S1
18V 4A
2 PL S+ S-
N+55
A
P T
BUS
J J
M M
P P
346230
J J
M M
P P
IN
346992
2 1 C
OUT
DESCRIPTION
351200
352100
344192
346000
346200
346830
346870
L
PE/S
PL
S1
WARNING
APARTMENT 18
ON
344192
BUS
=
N
=
=
P
=
=
M
=
1
8
=
=
=
P
=
=
M
=
N
OFF
max. 50 m
APARTMENT 9
344192
BUS
APARTMENT 2
ON
=
=
=
P
=
=
M
=
=
=
=
P
=
=
M
=
G
344192
BUS
APARTMENT 1
ON
346841
344192
BUS
50 m
IN
OUT
351200
352100
352100
max. 50 m
346870
PE/S
=
P
=
=
N
=1
S =
T =
M =
J1 =
JMP
346200
346000
BU S
TK
BUS
PI
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
S1
PS
PS
NF
CEBEC
IP30
BUS 2 1
5
1
6
2
7
3
8
4
230 Vac
NC
NO
DESCRIPTION
346000
346830
346991
346992
391670
Power supply
Video adapter
Universal speaker module
Key expansion module
2 WIRE outdoor camera
To the 346991
BUS terminal
NP
Z
M
A
PL
=
=
=N Z
=
=
=
=
Conf. in P = conf. in
346991 P
M A PL
To the handsets
Call
pushbuttons
=
=
=
N
=
S =
P
346991
P N S
BUS
8 7 6 5 4 3 2 1 C
346991
346000
BUS BUS
PI
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
PS
346830
BUS 2 1
230 Vac
2 1 C
IN
OUT
To other
modules 346992
BUS
P
391670
N
Z
M
A
PL
=
=
=
=
=
=
=
346992
NF
CEBEC
IP30
DESCRIPTION
351100
352100
352400
344082
344192
346000
346200
346830
346841
L
PE/S
PS
S1
WARNING
SWITCHED OFF. Also every time the configuration is
modified the power supply to the system must be
switchedoff and on again, waiting about 1 minute.
APARTMENT 15
ON
CONNECTION LIMITS
=
=
=
P
=
=
M
=
1
5
=
=
=
P
=
=
M
=
1
4
=
=
=
P
=
=
M
=
344192
BUS
APARTMENT 14
N
ON
344192
346841
BUS
APARTMENT 1
ON
APARTMENT 2
=
=
=
P
=
=
M
=
ON
344192
344082
BUS
346841
BUS
A
346000
352400
=
=
=
N
= 1 351100
S =
T =
M =
J1 = 352100
JMP
346200
PE/S
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
BUS 2 1
S1
230 Vac
PS
BUS
TK
NF
CEBEC
BUS
PI
IP30
5
1
PS
6
2
7
3
8
4
346830
NC
NO
L
230 Vac
DESCRIPTION
351300
352500
344704
344192
346000
346200
346830
3499
L
PE/S
PS
S1
WARNING
CONNECTION LIMITS
1 video EP, max. 2 risers on Handset BUS, item 346830
2 video EPs, max. 1 riser on Handset BUS, item 346830
APARTMENT 32
APARTMENT 11
=
=
=
P
=
=
M
=
N
ON
344192
1
1
ON
=3
=2
P =
N
3
2
1
344704
346841
BUS
BUS
APARTMENT 13
APARTMENT 2
=
N
=2
P =
ON
3
2
1
344704
344192
346841
=
=
=
P
=
=
M
=
1
3
=
=
=
P
=
=
M
=
1
2
ON
BUS
BUS
APARTMENT 1
APARTMENT 12
=
N
=
=
P
=
=
M
=
ON
D
344192
ON
344192
346841
BUS
BUS
3499
346000
351300
352500
PE/S
B
N
PRI
=
P
=
=
N
=
S =
T =
M =
JMP
JMP
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
230 Vac
PS
BUS
TK
NF
CEBEC
BUS
PI
IP30
BUS 2 1
S1
346200
5
1
PS
6
2
7
3
8
4
346830
NC
NO
L
230 Vac
DESCRIPTION
351200
352100
344192
346000
346200
346830
L
PE/S
PS
S1 - S2
WARNING
or generic actuations.
CONNECTION LIMITS
1 video EP, max. 2 risers on Handset BUS, item 346830
2 video EPs, max. 1 riser on Handset BUS, item 346830
APARTMENT 17
MASTER
=
=
P =
=
M
=
N
J2
IN
OFF
344192
1
7
SLAVE
J2
OUT
=
=
P =
=
M
=
N
ON
1
7
344192
BUS
APARTMENT 1
=
=
P =
=
M
=
N
OFF
344192
BUS
351200
PE/S
=
=1
=
N
=1
352100
S =
T =
M =
J1 =
JMP 352100
P
S1
PS
346200
346000
351200
=
P
=
=
N
=1
352100
S =
T =
M =
J1 =
JMP 352100
PE/S
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS
TK
NF
CEBEC
IP30
BUS 2 1
S2
PS
230 Vac
BUS
PI
PS
5
1
6
2
7
3
8
4
346830
NC
NO
L
230 Vac
DESCRIPTION
351200
352000
352500
344192
346000
346020
346200
346830
346841
L
PE/S
PE/S1
PL
S1 - S2
WARNING
CONNECTION LIMITS
1 video EP, max. 2 risers on Handset BUS, item 346830
2 video EPs, max. 1 riser on Handset BUS, item 346830
APARTMENT 4
=
=
P =
=
M
=
N
ON
344192
Ad altri derivatori di
piano o ad un citofono
o videocitofono
BUS
APARTMENT 1
=
=
P =
=
M
=
N
ON
344192
BUS
351200
346841
PE/S
=
=1
=
N
=1
352000
S =
T =
M =
JMP
J2 = 352000
P
230 Vac
PRI
S1
1- 2
PS
(*)
346020
A
351200
230 Vac
PE/S1
=
P
=
=
N
=
S = 352500
T =
M =
JMP
J2 =
346200
BUS BUS
PI
TK
N
PRI
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
PS
S2
BUS 2 1
(*)
(*) Remove the configurator from the socket (J2) to enable
additional entrance panel power supply
346000
PS
5
1
1- 2
346020
230 Vac
6
2
7
3
8
4
NC
C NO
346830
230 Vac
DESCRIPTION
351300
344192
346000
346200
346830
L
PE/S
PS
S1
WARNING
DEVICE 3
Intercom with
handset 1
Intercom with
handset 2
Intercom with
handset 5
Intercom with
handset 4
=
=
P =
=
M
=
N
ON
344192
E
DEVICE 5
Intercom with
handset 1
Intercom with
handset 2
Intercom with
handset 3
Intercom with
handset 4
BUS
DEVICE 2
Intercom with
handset 1
Intercom with
handset 5
Intercom with
handset 3
Intercom with
handset 4
=
=
P =
=
M
=
N
OFF
344192
Intercom with
handset 1
Intercom with
handset 2
Intercom with
handset 3
Intercom with
handset 5
DEVICE 1
OFF
344192
=
N
=
P =
=
M
=
344192
=
=
P =
=
M
=
BUS
Intercom with
handset 5
Intercom with
handset 2
Intercom with
handset 3
Intercom with
handset 4
=
=
P =
=
M
=
N
ON
DEVICE 4
N
OFF
344192
BUS
BUS
A
PE/S
=
P
=
=
N
=
S =9
T =
M =
JMP
JMP
346000
346200
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
351300
BUS
PI
NF
CEBEC
IP30
PS
S1
D
PS
BUS 2 1
230 Vac
5
1
6
2
7
3
8
4
NC
NO
346830
230 Vac
DESCRIPTION
351200
344192
346000
346830
346200
PE
PS
S1
A/V SFERA
POLYX VIDEO handset
Power supply
Video adapter
Staircase light actuator
SFERA entrance panel (main)
Door lock release pushbutton
Electric door lock 18 V 4 A impulsive
250 mA holding current (max. 30 Ohm)
WARNING
APARTMENT 1
APARTMENT 2
=
=1
=
P
=
=
MOD
=1
344192
ON
J2
OUT
SLAVE
Intercom inside
apartment
Intercom between
apartments 1 and 2
Relay actuator control
configured with
MOD=9 and P+1
Actuator control
346200 configured
with MOD=5 and
P+1 or 346230
configured with P+1
344192
OFF
J2
OUT
344192
OFF
J2
IN
MASTER
BUS
Intercom inside
apartment
Intercom between
apartments 1 and 2
Relay actuator control
configured with
MOD=9 and P+1
Actuator control
346200 configured
with MOD=5 and
P+1 or 346230
configured with P+1
=
=1
=
P
=
=
MOD
=1
N
SLAVE
=
=2
=
P
=
=
MOD
=1
N
J2
OUT
BUS
344192
ON
BUS
=
=1
=
P
=
=
MOD
=1
N
SLAVE
344192
=
=2
=
P
=
=
MOD
=1
N
OFF
J2
OUT
BUS
SLAVE
=
=2
=
P
=
=
MOD
=1
344192
OFF
J2
IN
BUS
BUS
MASTER
B
B
346000
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
MOD = 5
=
=
=
N/P
=1
T =
346200
BUS
PI
NF
CEBEC
IP30
PS
BUS 2 1
=
=
=
N
=1
S =
T =
M =
J1 =
JMP
351200
PE
7
3
8
4
NC
230 Vac
S1
PS
6
2
NO
346830
230 Vac
5
1
DESCRIPTION
351200
352000
344704
344824
346000
346200
346830
L
PE/S
PS
S1
APARTMENT 5
=
=
=
P
=
=
MOD
=
N
3
2
1
0
3
2
1
0
OFF
344704
BUS
=
=
=
P
=
=
MOD
=
5
3
=
=
=
P
=
=
MOD
=
5
3
3
2
1
0
The apartment intercom connection will be interrupted when a call is received from an EP.
The system only manages one intercom call at the time.
5
3
OFF
3
2
1
0
344824
APARTMENT 3
APARTMENT 4
=
=
=
P
=
=
MOD
=
N
ON
3
2
1
0
3
2
1
0
OFF
3
2
1
0
344824
351200
=
=
=
P
=
=
MOD
=
5
3
352000
BUS
=
=
=
P
=
=
MOD
=
N
3
2
1
0
OFF
3
2
1
0
344824
BUS
5
3
BUS
PE/S
=
=
=
N
=3
S =
T =
M =
JMP
JMP
P
352000
3
2
1
0
OFF
344704
N
3
2
1
0
BUS
344704
3
2
1
0
5
3
346000
346200
BUS
TK
N
PRI
S1
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS
PI
NF
CEBEC
IP30
PS
BUS 2 1
PS
230 Vac
5
1
6
2
7
3
8
4
NC
NO
346830
230 Vac
DESCRIPTION
351100
352000
352400
344192
346000
346200
346830
L
PE/S
PS
S1
WARNING
CONNECTION LIMITS
Intercom with
handset 1
Intercom with
handset 2
Intercom with
handset 5
Intercom with
handset 4
APARTMENT 5
Intercom with
handset 1
Intercom with
handset 2
Intercom with
handset 3
Intercom with
handset 4
=_
=5
=
P
=
=
MOD
=3
Intercom with
handset 1
Intercom with
handset 2
Intercom with
handset 3
Intercom with
handset 5
344192
344192
=_
=4
=
P
=
=
MOD
=3
N
OFF
344192
BUS
Intercom with
handset 1
Intercom with
handset 5
Intercom with
handset 3
Intercom with
handset 4
OFF
344192
BUS
APARTMENT 1
Intercom with
handset 5
Intercom with
handset 2
Intercom with
handset 3
Intercom with
handset 4
BUS
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
=_
=1
=
P
=
=
MOD
=3
N
OFF
344192
BUS
346200
BUS
TK
S1
=_
=2
=
P
=
=
MOD
=3
N
346000
APARTMENT 2
BUS
PE/S
=
P
=
=
N
= 1 351100
S =
T =
M =
JMP 352000
JMP
=_
=3
=
P
=
=
MOD
=3
N
OFF
ON
APARTMENT 4
352400
BUS to other
Handsets
APARTMENT 3
BUS
PI
NF
CEBEC
IP30
PS
BUS 2 1
PS
230 Vac
5
1
6
2
7
3
8
4
NC
NO
346830
230 Vac
DESCRIPTION
351200
351100
352100
344192
346000
346850
391670
F441
PE
PS
S - S1
To other Handsets /
apartment interfaces
346850
INT
B
D
EXT
ON
APARTMENT 2
OFF
WARNING
=
=2
M =3
N
ON
OFF
346850
EXT
CONNECTION LIMITS
APARTMENT 1
OFF
B
344192
Riser
3
Riser
2
Riser
4
BUS
F441
OUT1
351200
PE
OUT2
OUT3
346000
OUT4
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN1
352100
PRI
OUT
IN2
IN3
IN4
NF
CEBEC
IP30
BUS 2 1
SCS
230 Vac
=
=3
=
N
=1
Z =
M=
JMP
JMP
P
351100
BUS
BUS
BUS
S
=
P
=
=
N
=1
S =
T =
M =
J1 =
JMP
PS
391670
N
Z
M
A
PL
=
=
=
=
=
=
=
=
391670
N
Z
M
A
PL
=
=
=
=
=
=
=
=
391670
N
Z
M
A
PL
=
=
=
=
=
=
=
=
S1
PS
ITEM
DESCRIPTION
349410
351200
344163
349311
F441
346000
391670
PS
2 WIRE/analogue interface
SFERA A/V module
POLYX MEMORY DISPLAY video handset
VIDEO DISPLAY video handset
Audio/video node
Power supply
2 WIRE outdoor camera
Door lock release pushbutton
lock.
CLAMPS
349410
Video
2
3
4
5
6
7
8
9
10
11
12
2
3
4
5
6
7
8
14
Audio
1 and S+
(of the actuator)
3
4
5
A
14 (optional)
From the
analogue audio
building riser
wire 6
2 WIRE BUS
2
2 WIRE BUS
From the
analogue video
building riser
WARNING
PRIVATE APARTMENT
Entrance
Room
=
=1
P =
=
=2
P =
Kitchen
349311
=
=3
P =
N
349311
344163
F441
346000
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
230 Vac
APARTMENT
ENTRANCE PANEL
351200
BUS
S
PS
=
P =1
=
N
=
S =9
T =
M =
JMP
JMP
BUS
391670
P
N
Z
M
A
PL
=
=
=
=
=
=
=
=
391670
P
N
Z
M
A
PL
=
=
=
=
=
=
=
=
WARNING
ITEM
DESCRIPTION
351200
344192
346000
346850
F441
PEA
PS
S1
APARTMENT 2
344192
=
=
P =
M =
N
BUS
344192
ON
=
=
P =
M =
N
BUS
344192
ON
344192
ON
=
=
P =
M =
N
BUS
ON
=
=
P =
M =
N
To other
apartments or
apartment
interfaces
BUS
344192
OFF
=
=
P =
M =
N
BUS
346850
F441
346000
OUT1
OUT 2
O UT3
OUT 4
346850
IN T
PRI
OUT
EXT
ON
ON
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
NF
CEBEC
IP30
OF F
OFF
IN 1
I N2
IN 3
IN 4
BUS 2 1
SC S
=
=2
M =3
N
230 Vac
351200
BUS
PE A
BUS
P
S1
2 WIRE
building
riser
=
=1
=
N
=
S =9
T =
M =
JMP
JMP
P
PS
391657
391658
391659
391661
391662
391667
391668
391669
N
Z
M
A
PL
=
=
=
=
=
=
=
391670
N
Z
M
A
PL
=
=
=
=
=
=
=
DESCRIPTION
351200
346000
346830
346851
PE
PS
S1
F441
WARNING
BUS PI
346000
BUS BUS
PI
TK
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
PS
BUS 2 1
346830
200 m
Line B
230 Vac
346851
346851
=
=1
MOD =
ON
ON OFF
ON
OFF
F441
OUT1
OUT2
OUT3
346000
OUT4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN1
IN2
IN3
IN4
BUS 2 1
SCS
230 Vac
351200
NF
CEBEC
IP30
200 m
Line A
PE
=
=
=
N
=
S =
T =
M =
JMP
JMP
S1
PS
DESCRIPTION
351200
352500
352400
351100
352100
353000
344192
344824
346000
346850
346851
PE
PS
S1 S2 S3 S4
PEP
F441
Riser 1
APARTMENT 1
=
=
=
P
=
=
M
=
N
OFF
BUS
346851
344192
F441
OUT1
OUT2
OUT3
346000
OUT 4
346851
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
IN
=
=1
MOD = 5
ON
ON
OF F
ON OFF
IN 1
IN 3
I N2
IN 4
BUS 2 1
SC S
230 Vac
352400
F441
OUT1
OUT2
OUT3
346000
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
IN
IN 1
I N2
IN 3
BUS 2 1
SC S
IN 4
=
=2
=
N
=1
S =
T =
M =
J1 =
JMP
PEP
351100
S2
PS
352100
230 Vac
To other Entrance Panels or
common cameras
351200
=
=
=
352500
N
=
S =
T =
M =
JMP 353000
JMP
P
S2
A
PE
PS
The entrance panel must include at least one speaker module, A/V + display
module.
The 353000 keypad module gives the possibility of releasing the door lock
using a numerical code
APARTMENT 2
Riser 2
=
=2
M =3
N
346850
IN T
EXT
ON
ON
Riser 39
OF F
346850
ON OFF
APARTMENT 1
APARTMENT 1
=_
=1
=
P
=4
=
MOD
=
N
OFF
3
2
1
0
344824
BUS
346851
OUT2
OUT3
OFF
346851
OUT1
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
OUT2
OUT3
346000
346851
NF
PRI
OUT
CEBEC
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
OUT 4
IP30
NF
CEBEC
IP30
IN
ON
ON
344824
F441
OUT 4
346851
3
2
1
0
BUS
346000
F441
OUT1
=_
=1
=7
P
=8
=
MOD
=
N
ON
BUS 2 1
OFF
IN 1
I N2
IN 3
IN 4
SC S
230 Vac
BUS 2 1
OF F
IN 1
ON OFF
ON OFF
=
=2
MOD = 5
ON
I N2
IN 3
SC S
IN 4
=3
=9
MOD = 5
230 Vac
352400
PEP
PEP
352400
D
351100
=
P
=4
=
N
=1
S =
T =
M =
J1 =
JMP
351100
S3
PS
WARNING
352100
=7
P
=8
=
N
=1
S =
T =
M =
J1 =
JMP
S4
PS
A
352100
P=3
........
P=4
DEVICE 1
OFF
349320
DESCRIPTION
3499
349320
F441
346000
342991
391670
PE
PS
S1
Line terminator
Axolute Video Station Nighter
Audio/video node
Power supply
Linea 2000 Metal EP
2 WIRE outdoor camera
Entrance panel
Door lock release pushbutton (optional)
Electric door lock 18 V 4 A impulsive
250 mA holding current (max. 30 Ohm)
Outdoor camera
Indoor camera
TLC1-TLC3
TLC4-TLC7
BUS
ITEM
B
F441
OUT1
OUT2
OUT3
346000
OUT4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN1
IN2
IN3
IN4
NF
CEBEC
IP30
BUS 2 1
SCS
230 Vac
F441
OUT1
OUT2
OUT3
OUT4
OUT
IN
IN1
IN2
IN3
IN4
SCS
3499
P
N
T
S
=
=
=
=1
=
=9
342991
PE
BUS PL S+ SPS
N
Z
M
A
PL
=
=1
=
=
= 391670
=
=
N
Z
M
A
PL
P
N
Z
M
A
PL
=
=2
=
=
=
=
=
391670
S1
Camera 1
Camera2
=
=3
=
=
=
=
=
391670
Camera3
WARNING
When the nodes are used in cascade, the distances of the
various lines are halved (max. 100 m with cable item 336904).
F441
OUT1
OUT2
OUT3
F441
OUT4
OUT1
OUT2
OUT3
F441
OUT4
OUT
OUT
OUT
IN
IN
IN
IN1
IN2
IN3
IN4
SCS
IN1
3499
IN2
IN3
IN4
SCS
OUT1
OUT2
OUT3
IN1
IN2
IN3
3499
P
N
Z
M
A
PL
Camera 5
=
=4
=
=
=
=
=
P
N
Z
M
A
PL
Camera 6
=
=5
=
=
=
=
=
P
N
Z
M
A
PL
IN4
SCS
3499
Camera 4
OUT4
Camera 7
=
=6
=
=
=
=
=
P
N
Z
M
A
PL
=
=
=
=
=
=
=
OFF
7
LIVINGLight - WHITE
LIVINGLight Tech
LivingLIGHT - ANTHRACITE
Axolute - WHITE
Axolute Tech
Axolute - antHracite
DESCRIPTION
351200
352500
352400
352100
351100
344192
346000
346830
346850
346851
PE
PS
S1-S2-S3
PEP
F441
APARTMENT 1
Riser 1
344192
=
=
P =
=
M
=
N
OFF
BUS
F441
OUT1
OUT2
OUT3
346000
OUT4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN
IN1
IN2
1
2
IN3
IN4
NF
CEBEC
IP30
BUS 2 1
SCS
230 Vac
346851
=
M
=1
MOD = 5
PEP
351200
=
=2
=
N
=
S =
T =
M =
JMP
JMP
P
346851
ON
ON
352500
OFF
ON OFF
A
346851
=
M
=1
MOD = 2
F441
OUT1
OUT2
OUT3
C
346000
OUT4
346851
ON
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
ON
NF
CEBEC
IP30
OFF
ON
IN1
IN2
IN3
IN4
BUS 2 1
SCS
230 Vac
A
351200
PE
=
=
=
N
=
352500
S =
T =
M =
JMP
JMP
346830
346000
BUS BUS
PI
TK
S1
PRI
PS
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
PS
BUS 2 1
The Entrance Panel must be made with speaker module/A/V + display module.
230 Vac
S2
PS
WARNING
free address.
Riser 1 : P = 2
Riser 2 : P = 6
Riser 2
344192
=
=
P =
=
M
=
N
OFF
P=3
........
P=4
1
4
APARTMENT 2
BUS
346850
B
346850
INT
EXT
ON
ON
OFF
ON OFF
=
=2
M =3
EXT
F441
OUT1
OUT2
OUT3
346000
OUT4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN2
IN3
IN4
NF
CEBEC
IN
IN1
IP30
BUS 2 1
SCS
230 Vac
346851
=
=2
MOD = 5
M
=
=4
=
N
=
S =
T =
M =
J1 =
JMP
P
346851
ON
ON
352400
351100
OFF
ON OFF
S3
To other
risers
PS
352100
351200
352500
352400
351100
352100
344192
346000
346830
346851
PE
PEP
F441
S1 - S2 - S3
Riser 1
APARTMENT 51
=
=
P =
=
M
=
N
OFF
Max. 50 Handsets
on the 4 node outputs
ITEM
344192
BUS
F441
=
M
=1
MOD =
OUT1
OUT2
OUT3
5
1
2
346000
OUT4
346851
N
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN
NF
CEBEC
IP30
ON
OFF
ON
ON
IN1
IN2
IN3
BUS 2 1
SCS
IN4
346851
230 Vac
D
Max. 50 Handsets
on the 4 node outputs
APARTMENT 1
=
=
P =
=
M
=
N
OFF
BUS
F441
OUT1
OUT2
OUT3
344192
346000
OUT4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN2
IN3
IN4
NF
CEBEC
IN
IN1
1
2
IP30
BUS 2 1
SCS
230 Vac
352400 PEP
=
=1
MOD = 5
M
A
351200
PE
=
P
=
=
N
=
S =
T =
M =
JMP
JMP
346851
ON
ON
S2
OFF
OFF
346851
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
352500
PS
346000
BUS BUS
PI
TK
S1
NF
CEBEC
IP30
PS
BUS 2 1
PS
346830
230 Vac
=
=2
=
N
=1
S =
T =
M =
J1 =
JMP
P
351100
352100
APARTMENT 51
=
=
P =
=
M
=
N
Max. 50 Handsets
on the 4 node outputs
OFF
344192
BUS
346851
=
M
=2
MOD =
346000
F441
OUT1
OUT2
OUT3
5
1
4
OUT4
346851
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN
ON
ON
PRI
OUT
NF
CEBEC
IP30
OFF
ON
IN1
IN2
IN3
IN4
BUS 2 1
SCS
230 Vac
D
APARTMENT 1
=
=
P =
=
M
=
Max. 50 Handsets
on the 4 node outputs
OFF
BUS
344192
1
4
B
WARNING
F441
OUT1
OUT2
OUT3
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN2
IN3
IN4
NF
CEBEC
IN
IN1
346000
OUT4
IP30
BUS 2 1
SCS
230 Vac
346851
ON
PEP
=
=4
=
N
=1
S =
T =
M =
J1 =
JMP
P
ON
OFF
=
=2
MOD = 5
M
OFF
S3
346851
PS
To other
risers
351100
352100
P=4
DESCRIPTION
351300
346000
346841
346850
349320
349321
F441
S1
When the handsets are configured as shown, the intercom function for all devices is enabled. Upon receipt of a call from
the EP, all handsets will ring, but only the handset configured with N = 1 will switch on.
To enable the video handsets to switch on simultaneously, it will be necessary to power each handset locally using the
additional power supply item 346020.
APARTMENT 16
B
B
ON
=
=4
P =1
N
C
ON
=
=3
P =1
N
349320
349320
=
=5
P =1
=
=2
P =1
ON
ON
349321
349320
346841
=
=1
P =1
N
ON
F441
349321
OUT1
OUT2
OUT3
OUT 4
OUT
IN 1
346850
IN T
To other
apartments
EXT
OFF
ON
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
346850
346000
I N2
IN 3
IN 4
SC S
NF
CEBEC
IP30
BUS 2 1
230 Vac
PE
ON
OF F
=1
=6
M =3
Building
riser
351300
S1
PS
=
=1
=
N
=
S =9
T =
M =
JMP
JMP
P
WARNING
ON
=
=9
P =1
N
349321
=1
=0
P =1
N
=
=7
P =1
ON
ON
346841
349321
349320
=
=8
P =1
ON
=
=6
P =1
ON
349320
349320
F441
OUT1
OUT2
OUT 3
O UT4
OUT
IN 1
=
=1
MOD =
346851
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN
346000
I N2
IN 3
IN 4
SC S
NF
CEBEC
IP30
BUS 2 1
230 Vac
ON
ON
ON
OF F
346851
DESCRIPTION
351300
346000
346830
346841
346851
349320
349321
F441
347400
S1
=
=3
P =
=
=4
P =
ON
ON
349321
349320
=
=2
P =
N
B
ON
=
N
=3
P =
ON
349320
349321
ON
=
N
=4
P =
346841
=
=1
P =
ON
349320
349320
ON
=
=2
P =
N
ON
346000
=
=1
MOD =
=
=5
P =
349321
349321
BUS BUS
PI
TK
346851
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
ON
PS
OFF
ON
BUS 2 1
346851 346830
230 Vac
346841
=
=1
P =
NF
CEBEC
IP30
ON
B
N
F441
ON
OUT1
OUT2
OUT3
OUT4
OUT
349320
346000
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN1
IN2
IN3
IN4
NF
CEBEC
IP30
SCS
BUS 2 1
230 Vac
PE
351300
=
P
=
=
N
=1
S =9
T =
M =
JMP
JMP
S1
PS
ON
=
N
=5
P =
349320
N
T
M
A
PL
=
=1
=
=
=
=
=
2 WIRE cameras
P
N
T
M
A
PL
=
=2
=
=
=
=
=
P
N
Z
M
A
PL
=
=3
=
=
=
=
=
347400
Tlc 12 Vdc
150 mA
max 3 m
WARNING
Upon arrival of the call, all Handsets ring and all those configured with N = 1 switch on. The INTERCOM call causes all
handsets with the same configuration to ring.
To activate the intercom on all the handsets see the previous diagram.
To enable the video handsets to switch on simultaneously, it will be necessary to power each handset locally using the
additional power supply item 346020.
ON
ON
= 349320
N
=3
P =
= 349321
N
=4
P =
ON
ON
C
= 349321
=3
P =
= 349320
=4
P =
ON
ON
B
= 349321
=2
P =
= 349321
=5
P =
ON
ON
346841
= 349320
=2
P =
= 349320
=5
P =
N
346841
ON
= 349320
=1
P =
ON
= 349320
=1
P =
N
346851
346851
346830
PRI
ON
ON
346000
BUS BUS
PI
TK
PS
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
346851
NF
CEBEC
OFF
346851
ON
=
=2
MOD =
346830
IP30
BUS 2 1
PRI
ON
230 Vac
ON
346000
BUS BUS
PI
TK
PS
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
OFF
ON
=
=3
MOD =
BUS 2 1
230 Vac
DESCRIPTION
346310
346020
F441
346000
Switchboard
Additional power supply
Audio/video node
Power supply
WARNING
Additional power supply item 346020 recommended
For the functional check and the calculation of current absorptions use the YouDiagram software - which can be downloaded free of
charge from the website www.international.bticino.com
For the configuration of the switchboard refer to the documentation supplied with the product or the configuration software
346310
230 Vac
346020
PRI
1- 2
2 1
BUS
To Handsets or
riser interfaces
F441
OUT1
OUT2
OUT3
346000
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN 1
I N2
IN 3
IN 4
BUS 2 1
SC S
230 Vac
Main EP
(P = 1)
NF
CEBEC
IP30
DESCRIPTION
346310
346020
F441
346000
346851
Switchboard
Additional power supply
Audio/video node
Power supply
System expansion module
WARNING
Additional power supply item 346020 recommended
For the functional check and the calculation of current absorptions use the YouDiagram software - which can be downloaded free of
charge from the website www.www.international.bticino.com
For the configuration of the switchboard refer to the documentation supplied with the product or the configuration software
The switchboard does not manage riser EPs and apartment EPs
Riser 1
Riser 2
346851
F441
OUT1
OUT2
OUT3
346000
OUT1
346851
OUT2
OUT3
346000
OUT 4
346851
N
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN
NF
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
CEBEC
IP30
IN
ON
ON
F441
346851
OUT 4
NF
CEBEC
IP30
ON
OF F
IN 1
ON OFF
I N2
IN 3
IN 4
=
=1
MOD = 5
ON
BUS 2 1
SC S
IN 1
ON OFF
I N2
IN 3
IN 4
=
=2
MOD = 5
230 Vac
OFF
230 Vac
Riser EP
BUS 2 1
SC S
Riser EP
To other interfaces 346851
346310
230 Vac
346020
PRI
1- 2
BUS
F441
OUT1
OUT2
OUT3
OUT 4
346000
N
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN 1
I N2
IN 3
IN 4
2 1
NF
CEBEC
IP30
BUS 2 1
SC S
230 Vac
Main EP
(P = 1)
DESCRIPTION
346310
346020
F441
346000
Switchboard
Additional power supply
Audio/video node
Power supply
WARNING
Additional power supply item 346020 recommended
Max. 3 switchboards that can be connected with star type connection to a video/audio node With the IN/OUT connection it is possible
to connect up to 16 switchboards and 80 EPs
For the configuration of the switchboard refer to the documentation supplied with the product or the configuration software
Riser 1
Riser 2
346851
F441
OUT1
OUT2
OUT3
346000
OUT1
346851
OUT2
OUT3
346000
OUT 4
346851
N
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
NF
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
CEBEC
IP30
IN
ON
ON
F441
346851
OUT 4
NF
CEBEC
IP30
ON
OF F
ON OFF
IN 1
I N2
IN 3
IN 4
BUS 2 1
SC S
=
=1
MOD = 5
ON
ON OFF
IN 1
I N2
IN 3
IN 4
=
=2
MOD = 5
230 Vac
OFF
230 Vac
Riser EP
Riser EP
346310
BUS 2 1
SC S
230 Vac
346020
PRI
1- 2
2 1
BUS
F441
OUT1
OUT2
OUT3
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN 1
I N2
IN 3
IN 4
346310
346000
NF
CEBEC
230 Vac
IP30
BUS 2 1
SC S
346020
PRI
230 Vac
1- 2
BUS
Main EP
(P = 1)
2 1
DESCRIPTION
ITEM
DESCRIPTION
346310
346020
F441
346000
E46ADCN
Switchboard
Additional power supply
Audio/video node
Power supply
Power supply
F422
3480
4615
346851
SCS/SCS gateway
Contact interface
Auxiliary channel interface
System expansion module
Riser 1
Riser 2
ON OFF
346851
=
=2
MOD = 5
M
ON
ON
346851
346851
=
=1
MOD = 5
ON
346851
346851
OF F
Riser 3
346851
ON
WARNING
OFF
ON OFF
ON
ON
ON OFF
OFF
=
=3
MOD = 5
M
BUS
346310
230 Vac
F441
OUT1
OUT2
OUT3
346020
346000
OUT 4
PRI
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
NF
CEBEC
IP30
1- 2
IN 1
I N2
IN 3
IN 4
BUS 2 1
SC S
2 1
230 Vac
E46ADCN
Main EP
(P = 1)
F422
OUT
F422
IN
I1
I2
I3
I4
MOD
=
=
=
= 1 (*)
=3
230V a.c .
3480
NC pushbutton
NO pushbutton
Technical alarm activation
Z1 = 9
N1 = 1
MOD1 =
Z2 =
N2 =
MOD2 = 1-9
4615
N
AUX
MOD
T
NC pushbutton
N = 2
AUX = 1-9
MOD =
Alarm Reset
WIRING DIAGRAMS
DESCRIPTION
ITEM
DESCRIPTION
346310
346020
F441
346000
Switchboard
Additional power supply
Audio/video node
Power supply
346830
346841
346851
3499
Video adapter
Floor shunt
Riser interface
Line terminator
WARNING
In systems with several switchboards, secondary switchboards
must be powered locally with an additional power supply item
346020
For the configuration of the switchboard refer to the
documentation supplied with the product or the
configuration software
3499
346851
346830
BUS
TK
OUT
346000
BUS
PI
N
PRI
IN
ON
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
ON
NF
CEBEC
IP30
PS
OFF
BUS 2 1
230 Vac
346841
Switchboard 5
Switchboard 6
3499
346841
Switchboard 9
Switchboard 10
F441
OUT1
OUT2
OUT3
346000
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN 1
I N2
IN 3
IN 4
NF
CEBEC
IP30
BUS 2 1
SC S
3499
230 Vac
346841
Switchboard 13
Switchboard 14
Main EP (P=1)
346310
Main switchboard = 0
230 Vac
346310
346020
PRI
BUS
Secondary switchboard = 3
230 Vac
1- 2
2 1
346020
PRI
BUS
1-
2 1
346310
Secondary switchboard = 4
230 Vac
346310
346020
PRI
Secondary switchboard = 7
BUS
230 Vac
1- 2
2 1
346020
PRI
BUS
1-
2 1
346310
Secondary switchboard = 8
230 Vac
346310
346020
PRI
Secondary switchboard = 11
BUS
230 Vac
1- 2
2 1
346020
PRI
BUS
1-
2 1
346310
Secondary switchboard = 12
230 Vac
346310
346020
PRI
Secondary switchboard = 15
BUS
230 Vac
1- 2
2 1
346020
PRI
BUS
1-
2 1
WIRING DIAGRAMS
APARTMENT 2
=
= 1
P =
M =
N
ON
BUS
346850
PSTN
346850
INT
345020
ON
=
N
=
P =
M =
OFF
BUS
EXT
ON
ON
OFF
PSTN
345020
346000
BUS
TK
a b
IN
BUS
PI
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
PLT1
NF
CEBEC
OUT
a b
IP30
PS
PLT1
BUS 2 1
346830
230 Vac
=
= 2
M = 3
N
346850
INT
OFF
EXT
ON
ON
OFF
346850
F441
OUT1
OUT 2
O UT3
346000
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN 1
I N2
IN 3
IN 4
NF
CEBEC
IP30
BUS 2 1
SCS
230 Vac
352400
=
P
=
=
N
=1
S =
T =
M =
J1 =
JMP
352400
PE/S
351100
S1
352100
PS
=
P
=1
=
N
=1
S =
T =
M =
J1 =
JMP
PE/S
351100
S2
352100
PS
=
= 1
P =
M =
N
BUS
PSTN
=
=
P =
M =
ON
ON
BUS
PSTN
345020
=
=
P =
M =
N
345020
=
=
P =
M =
N
OFF
OFF
BUS
PSTN
BUS
PSTN
345020
345020
F441
OUT 2
O UT3
346000
OUT 4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
a b
IN
NF
CEBEC
IP30
PLT1
IN 1
I N2
IN 3
IN 4
BUS 2 1
SCS
OUT
a b
PLT1
230 Vac
=
= 1
M = 3
EXT
OFF
OFF
346850
P
N
Z
A
PL
ON
ON
BUS
346850
INT
=
=
=
=
=
=
3916..
APARTMENT 1
ITEM
DESCRIPTION
QuantitY
ITEM
DESCRIPTION
QuantitY
PLT1
345020
352400
351100
352100
F441
346000
346850
2
6
2
2
2
2
3
3
346830
PE/S
391657
391658
391659
391661
391662
391663
Video adapter
SFERA entrance panel (main)
1
2
Wiring versions
230 Vac
346000
OUT1
OUT2
OUT3
346230
F441
OUT4
346020
1 2 PL S+ S-
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
349140
346230
OUT
NF
BUS
CEBEC
IN
IP30
35,
3 7
IN1
BUS 2 1
IN3
IN2
IN4
SCS
230 Vac
NOTE (*): Additional power supply needed for distances (EP-SCS power supply) exceeding 50 m (with cable item 336904 ).
ETHERNET IP CONNECTION
PE
346000
230 Vac
346230
346020
35,
1 2 PL S+ S-
346230
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
3 7
C9455
SWITCH
BUS 2 1
349140
230 Vac
BUS
'&,Q
IP
NOTE (*): Additional power supply needed for distances (EP-SCS power supply) exceeding 50 m (with cable item 336904 ).
To the BASIC 351000 speaker module it is possible to connect ONLY pushbutton modules
352000/352100, with all the pushbuttons on single column, or all on double column- mixed
solutions are NOT possible.
Pushbutton 352000
module
352100
Inductive loop
module
352700
Speaker module
351100
inductive loop module and voice synthesis of controls 352700, and the N&D
352400
A/V 351200
module 351300
1
Display
module
352500
All the other electronic modules must be connected complying with the following
connection order:
1. Display module 352500 (ONLY 1 per installation)
2. Door lock release modules (keypad 353000, badge reader 353200, and fingerprint
reader 353300)
NOTES:
- The use of display module 352500 prevents the installation of pushbutton modules 352000/352100, and vice
versa.
- The nameplate module 352200 may be installed without limitations (with the exception of the system
absorption limits), in conjunction with display module 352500 and/or door lock release modules.
- The door lock release modules (keypad 353000, badge reader 353200, and fingerprint reader 353300) can be
Pushbutton module
352000
352100
used individually and/or at the same time, also in STAND ALONE installations.
230 Vac
351000
PRI
BUS
346040
PRI 110 - 240 V 50 - 60 Hz 370 mA - 225 mA
BUS 26.0 V 600 mA
BUS
BUS
BUS
BUS
Pushbutton
module
352000
352100
NOTE: other pushbutton modules 352000/352100 may be installed, complying with the installation requirements for SFERA NEW-SFERA ROBUR entrance panels.
351100
BUS
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
BUS 2 1
230 Vac
Pushbutton
module
352000
352100
BUS
NOTE: other pushbutton modules 3520000/352100 may be installed, complying with the installation requirements for SFERA NEW-SFERA ROBUR entrance panels.
Speaker
module
351100
BUS
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
BUS 2 1
Display
module
352500
230 Vac
BUS
NOTE: The residents address book of display module 352500 must be created using a PC and the TiSferaDesign software, and then downloaded to the module using a USB interface.
Audio/video
module
351200
351300
351200
351300
A/V module
J1=JMP
J2=
Remove J2 to
enable additional
power supply
BUS PI
BUS PI
Pushbutton
module
BUS PE
352000
352100
346000
Power supply
Video adapter
BUS
TK
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
Video
adapter
BUS
PI
NF
BUS
TK
BUS
PI
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
CEBEC
IP30
PS
PRI
NF
CEBEC
346020
IP30
PS
346830
BUS 2 1
230 Vac
Additional
power supply
346000
Power supply
346830
230 Vac
PRI:
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
BUS 2 1
346020
230 Vac
NOTE: In installations with over 26 handsets an additional power supply is required, connected
to the entrance panel speaker module. To connect the additional power supply, configurator J2
must be removed from the speaker module.
Camera
module
Inductive loop
module
352400
Speaker
module
352700
BUS PI
351100
BUS PE
A/V module
346000
Power supply
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS PI
Video adapter
BUS
TK
PRI
NF
BUS
PI
346830
351200
351300
Power supply
346000
Video adapter
CEBEC
BUS
TK
IP30
PS
BUS
PI
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
PS
BUS 2 1
346830
BUS 2 1
230 Vac
230 Vac
NOTE: The residents address book of display module 352500 must be created using a PC and
the TiSferaDesign software, and then downloaded to the module using a USB interface.
342150
230 Vac
336842
12 V
BUS C NO
Power supply
PRI
PRI
12V
336842
BUS
346040
PRI 110 - 240 V 50 - 60 Hz 370 mA - 225 mA
BUS 26.0 V 600 mA
230V
BUS
BUS
BUS
346040
230 Vac
342240
Pushbutton module
NOTE: other pushbutton module Item 342240 can be installed in respect to the installed standards of the SFERA CLASSICentrance panels. Allow for a transformer 336842 for the powering of the door lock.
SFERA CLASSIC Entrance Panels to be installed on audio systems with power supply, item 346000
Speaker
module with
graphic display
Speaker
module
342170
342630
BUS BUS
Power supply
PRI
PRI
NF
346000
346000
CEBEC
PRI 230 V~ 50 - 60PRI
Hz230
260V~
mA
50 - 60 Hz 260 mA
BUS
BUS
IP30
2 - 1 27V 1,2A
2 - 1 27V 1,2A
BUS BUS
Power supply
346000
NF
PRI
CEBEC
PRI
346000
NF
346000
346000
CEBEC
PRI 230 V~ 50 - 60PRI
Hz230
260V~
mA
50 - 60 Hz 260 mA
BUS 27V 1,2A
BUS 27V 1,2A
IP30
2-1
2-1
IP30
BUS BUS
PL S+
PLS-S+ S-
IP30
BUS BUS
PL S+
PLS-S+ SBUS BUS
2121
Pushbutton
module
NF
CEBEC
BUS BUS
2121
230 230
Vac Vac
230 230
Vac Vac
BUS BUS
BUS BUS
342240
NOTE: other pushbutton module item 342240 can be installed in respect to the installed standards
of the SFERA CLASSIC entrance panels.
Connect the orange card (CT15/11) supplied with the speaker module to the last SFERA
CLASSIC pushbutton module.
NOTE: It is not necessary to install other modules. Item 342630 must be programmed downloading
by the appropriate RS232 interface item 335919 or USB (item 3559) the directory created with a
PC and the TICALL software (provided with it). The programming can be made also without a PC
through an infrared remote control item 392123.
Speaker
module
Double keys
speaker module 342350
342170
Power supply
346000
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
BUS
Power supply
PRI
NF
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
CEBEC
IP30
BUS PL S+ S-
Numeric call
module
BUS 2 1
230 Vac
BUS
342480
Double keys
module
NOTE: other nameplate modules item 342200 can be installed in respect to the installed standards of the SFERA CLASSIC entrance panels.
NF
CEBEC
IP30
BUS PL S+ SBUS 2 1
342610
346000
230 Vac
BUS
BUS
JMP 3
JMP 1
Camera
module
342510 (b/w)
342550 (colour)
JMP 4
JMP 2
Speaker module
342170
Camera
module
342510 (b/w)
342550 (colour)
JMP 1
JMP 4
JMP 2
BUS PI
1
BUS PL S+ S-
BUS PE
Power supply
Power supply
230 Vac
BUS
PI
BUS
TK
N
BUS
TK
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
PS
PRI
346020
BUS 2 1
346830
Video
adapter
230 Vac
PRI:
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
Additional
power supply
346020
IP30
ART.342560
J2
J1
USB
Additional
power supply
346020
IP30
PRI
BUS 2 1
NOTE: in systems with more than 26 handsets install an additional power supply to be connected
to speaker module of entrance panel. For connecting the additional power supply remove from
the speaker module the JMP3 jumper. Other pushbutton module Item 342240 can be installed in
respect to the installed standards of the SFERA CLASSIC entrance panels.
J1 J2
230 Vac
BUS
PI
NF
CEBEC
PS
230 Vac
Additional keypad
342640
346000
PRI
NF
CEBEC
BUS PE
Additional
modules
346000
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS PL S+ S-
346020
346830
Video
adapter
PRI:
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
NOTE: in systems with more than 26 handsets install an additional power supply to be connected
to speaker module of entrance panel. For connecting the additional power supply remove from the
speaker module the JMP3 jumper. Using the display call module is not necessary to install other
modules. Item 342630 must be programmed downloading by the appropriate RS232 interface
item 335919 or USB (item 3559) the directory created with a PC and the TICALL software. The
programming can be made also without a PC through an infrared remote control item 392123.
A/V module
342560
P
TS
BUS
PL S+ S
BUS PL S+ S-
Remove the J1
BUS PI
2 1
BUS PE
230 Vac
Additional
power supply
346020
PRI
346020
PRI:
SCS:
220 240 V~
175 165 mA
47/63 Hz
27 Vdc
600 mA
346000
Power supply
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS
PI
NF
CEBEC
IP30
PS
BUS 2 1
230 Vac
346830
Video
adapter
NOTE: in systems with more than 26 handsets install an additional power supply to be connected
to speaker module of entrance panel. For connecting the additional power supply remove from the
speaker module the JMP3 jumper.
342510 (b/w)
342550 (colour)
Camera module
Camera module
Speaker module
BUS PI
BUS PL S+ S-
342170
Power supply
342240
342630
BUS PE
Pushbutton
module
346000
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS PI
BUS PL S+ S-
BUS
PI
NF
BUS PE
Power supply
Video
adapter
346830
CEBEC
IP30
342640
PS
346000
BUS
TK
Additional
keypad
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
BUS
PI
NF
Video
adapter
346830
CEBEC
IP30
PS
BUS 2 1
BUS 2 1
230 Vac
230 Vac
NOTE: other pushbutton module Item 342240 can be installed in respect to the installed standards
of the SFERA entrance panels.
NOTE: It is not necessary to install other modules. Item 342630 must be programmed downloading by
the appropriate RS232 interface item 335919 or USB (item 3559) the directory created with a PC and the
TICALL software. The programming can be made also without a PC through an infrared remote control
item 392123.
342510 (b/w)
342550 (colour)
342560
Camera module
A/V module
ART.342560
J2
J1
USB
N
P
TS
Speaker module
342170
BUS PE
Power supply
342610
346000
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS
PL S+ S
BUS PL S+ S-
BUS PI
BUS PI
BUS PL S+ S-
Numeric
call
module
NF
BUS
PI
Video
adapter
346830
342480
or
342240
Pushbutton
module
BUS PE
Power supply
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
CEBEC
IP30
346000
NF
CEBEC
PS
BUS 2 1
BUS 2 1
NOTE: other nameplate modules item 342200 can be installed in respect to the installed standards
of the SFERA entrance panels.
Video
adapter
346830
IP30
PS
230 Vac
BUS
PI
230 Vac
NOTE: other pushbutton module item 342240 or item 342240 can be installed in respect to the
installed standards of the SFERA entrance panels.
EP speaker module
J2
J1
USB
P
TS
BUS PI
J2
J1
USB
P
TS
2 1
BUS PL S+ S
2 1
BUS PL S+ S-
BUS PL S+ S
BUS PE
Power supply
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
346000
Video
adapter
BUS
TK
BUS
PI
NF
CEBEC
IP30
PS
346830
BUS 2 1
230 Vac
EP speaker module
J1 J2
Remove
J1
J2
J1
USB
P
TS
2 1
BUS PL S+ S
BUS PI
BUS PL S+ S-
2 1
BUS PE
Power supply
230 Vac
346000
BUS
TK
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
BUS
PI
Video
adapter
346020
NF
PRI:
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
CEBEC
IP30
PS
346020
PRI
BUS 2 1
346830
Additional
power supply
230 Vac
NOTE: in systems with more than 26 handsets install an additional power supply to be connected to
speaker module of entrance panel. Before connecting the additional power supply remove from the
speaker module the J1 jumper.
Speaker module
230 Vac
BUS PI
346040
PRI
PRI
BUS
346040
PRI 110 - 240 V 50 - 60 Hz 370 mA - 225 mA
BUS 26.0 V 600 mA
BUS
OUT
Power supply
BUS
IN
OUT
BUS
L
E
D
342704
342702
NOTE: other pushbutton expansion module item 342704 can be installed in respect to the installed standards of the MINISFERA
entrance panels. MINISFERA Entrance Panels cannot be powered locally.
BUS PI
BUS PE
Power supply
IN
346000
OU T
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
L
E
D
BUS
PI
Video
adapter
NF
CEBEC
IP30
PS
342704
BUS 2 1
342708
230 Vac
NOTE: other pushbutton expansion module item 342704 can be installed in respect to the installed standards of the MINISFERA
entrance panels. MINISFERA Entrance Panels cannot be powered locally.
346830
342911
342921
342971
342972
PRI
BUS
PRI
BUS
346040
PRI 110 - 240 V 50 - 60 Hz 370 mA - 225 mA
BUS 26.0 V 600 mA
BUS
N TS
Power supply
BUS
BUS
LINEA 2000/LINEA 2000 METAL Entrance Panels to be installed on video mono and two-family
BUS PI
342951
342961
342981
342982
342991
342992
343001
343002
BUS PL S+ S-
346000
Power supply
Video
adapter
BUS BUS
PI
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
PS
346830
P N TS
BUS 2 1
230 Vac
BUS
Example separate camera connected in IN-OUT on the speaker module, item 342170
The interface item 347400 (used for the connection of the separate camera) and the relating speaker module must be configured with the same
value in P.
BUS PI
BUS PE
Power supply
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
=
=
=
N
=
T =
P
346000
BUS
TK
BUS
PI
Video
adapter
NF
Speaker
module
CEBEC
342170
IP30
PS
BUS 2 1
346830
BUS PL S+ S-
N
Z
M
A
PL
Coaxial/2 WIRE
interface
*
=
=
=
=
=
=
=
347400
230 Vac
max 3 m
Tlc 12 Vdc
150 mA
* Connecting
the camera in
IN-OUT, the interface
must be the device
which ends the line
NOTE: the Entrance Panel so created (speaker module item 342170 and separate camera) must be considered as a video Entrance Panel both for the number of risers
connectable and for the Handsets number.
BUS PI
BUS PE
BUS PE
346000
Power supply
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
BUS BUS
PI
TK
NF
Video
adapter
=
=
=
N
=
T =
P
CEBEC
IP30
PS
Speaker
module
342170
346830
BUS 2 1
BUS PL S+ S-
230 Vac
P
N
Z
M
A
PL
Coaxial/2 WIRE
interface
=
=1
=
=
=
=
=
Speaker
module
347400
=
=
=
N
=
T =
P
342170
max 3 m
BUS PL S+ S-
Tlc 12 Vdc
150 mA
BUS
NOTE: the camera must be considered as a video Entrance Panel both for the number of connectable risers and for the number of Handsets
OUT1
OUT2
OUT3
OUT4
IN1
IN2
IN3
IN4
F441
OUT
IN
P
N
Z
M
A
PL
SCS
347400
=
=
=
=
=
=
=
COAX
COAX
18
1/2 Watt
max. 1 m
COAX
E45/24DC
COAX
1 2 7 8
DVR TVCC
IN
337320
OUT
Max. 800 m
Handsets
F441
OUT1
OUT2
OUT3
346000
OUT4
PRI
OUT
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
IN
IN1
IN3
IN2
IN4
NF
CEBEC
IP30
BUS 2 1
SCS
230 Vac
BUS
BUS
P
N
Z
M
2 WIRE flush
mounted camera A
PL
=
=1
=
=
=
=2
=1
P
N
Z
M
A
PL
391670
=
=2
=
=
=
=1
=1
OUT
F422
OUT
L1
L
230 Vac
N
ART.F422
L2
I1
I2
I3
I4
MOD
=
=
=
=1
=
IN
346000
A =1
PL = 1
F411/1N
1
A =2
PL = 1
F411/1N
1
F411/1N
C1
F411/1N
C1
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
CEBEC
IP30
BUS
230 Vac
230 Vac
346982 - 346983
346984 - 349412
349413
3499
ON
PRI
230 Vac
J1
OUT
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
346020
BUS
=
N
=
=
P
=
=
BUS M
=
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
346020
J1
OUT
344192
346020
=
N
=
=
P
=
=
BUS M
=
ON
PRI
344192
346020
PRI:
230 Vac
J1
OUT
PRI
344192
346020
PRI:
ON
PRI:
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
=
=
=
P
=
=
BUS M
=
N
346020
344192
NOTES:
If the melodic bell is installed in video systems as last riser
or line device, it is necessary to install a line terminator, item
3499.
ON
=
=
=
P
=
=
M
=
N
BUS
346841
Handset BUS
(to 346830 or F441)
ON
=
=
=
P
=
=
M
=
N
ON
=
=2
P =
336982
336803
BUS
5 - brown
6 - brown - white
OUT3
346000
OUT 4
PRI
OU T
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
IN
IN 1
I N2
IN 3
IN 4
Video sources
NF
CEBEC
OUT2
IP30
BUS 2 1
SC S
230 Vac
8 7 6 5
OUT2
34
1 2 3 4
F441
OUT1
12
BUS
audio
=
=2
=
P
=
M
=
N
BUS
BUS
audio
=
=2
=
P
=
M
=
N
OFF
BUS
344082
=
=2
=
P
=
M
=
N
OFF
BUS
344082
OFF
344082
Example - one ADDITIONAL audio handset and bell to basic video handset
APARTMENT 11
=1
=1
=
P
=
M
=
N
OFF
344192
=1
=1
=
P
=
M
=
ON
1
5
1
5
344082
336992
336993
336994
BUS
336910
BUS
from floor shunt (346841) or audio/video node (F441)
=
M
=
N
OFF
=
=3
=
P
=
M
=
N
OFF
344192
344082
BUS
ON
=
=3
=
P
=
M
=
N
344082
BUS
BUS
from floor shunt (346841) or audio/video node (F441)
Example - AN AUDIO HANDSET AND A melodic BELL, IN ADDITION TO THE BASIC video HANDSET
APARTMENT 12
=1
=2
=
P
=
M
=
N
=1
=2
=
P
=
M
=
N
OFF
N1 =
N2 =
S =
M =
OFF
1
2
344082
344192
BUS
346982
346983
346984
349412
349413
BUS
Melodic bell
3499*
BUS
from floor shunt (346841) or audio/video node (F441)
APARTMENT 1
=
=1
=
P
=
M
=
=
=1
=
P
=
M
=
=
=1
=
P
=
M
=
OFF
J2
IN
OFF
J2
OUT
J2
OUT
SLAVE
MASTER
344192
ON
344192
BUS
SLAVE
344192
BUS
Handset BUS
from floor shunt (346841) or audio/video node (F441)
APARTMENT 4
=
=4
=
P
=
M
=
N
=
=4
=
P
=
M
=
N
OFF
J2
IN
344192
MASTER
BUS
=
=4
=
P
=
M
=
N
OFF
J2
OUT
344192
SLAVE
BUS
OFF
J2
OUT
344192
SLAVE
230 Vac
230 Vac
PRI
PRI
346020
346020
PRI:
220 240 V~
175 165 mA
47/63 Hz
PRI:
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
SCS:
27 Vdc
600 mA
346020
1
=1
N
=1
=
P
=
M
=
BUS
PI
346020
=1
N
=1
=
P
=
M
=
ON
ON
J1
OUT
=1
N
=1
=
P
=
M
=
ON
J1
OUT
344192
344192
BUS
344192
BUS
BUS
346841
Handset BUS
Example - ONE HANDSET AND AN ADDITIONAL BELL TYPE BADENIA ADDED TO THE BASIC VIDEO HANDSET
APARTMENT 15
=1
=5
=
P
=
M
=
N
=1
=5
=
P
=
M
=
346200
OFF
344192
OFF
3499*
NC C NO
344082
BUS
MOD = SLA
=
M
=
= 1
P/N
= 5
T = 2
5
1
6
2
7
3
8
4
BUS
Handset BUS
from floor shunt (346841) or
audio/video node (F441)
230 Vac
Additional
power supply
PRI
346020
PRI:
220 240 V~
175 165 mA
47/63 Hz
SCS:
27 Vdc
600 mA
346020
1
230Vac
89. xx
90. xx
91. xx
NOTE (*): If the actuator is installed as the last line or riser device, allow for a line termination,
item 3499
to Handsets
Audio/video
node
to EP
346000
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
OUT 1 OUT2
Video
adapter
BUS
PI
OUT3
OUT
NF
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
CEBEC
IP30
346000
OUT4
IN
NF
CEBEC
IP30
PS
BUS 2 1
346830
IN 1
IN 2
IN 3
IN 4
BUS 2 1
SCS
F441
230 Vac
230 Vac
to EP
Handset risers
F441M
OUT 1
TK1
OUT 2
TK2
OUT 3
TK3
OUT 4
TK4
OUT 5
S1
OUT 6
S2
OUT 7
S3
OUT 8
S4
346000
BUS 2 1
BUS
230 Vac
Entrance Panels
or cameras
Sound sources
BUS PE
APARTMENT 2
344192
ON
=
=
=
P
=
=
M
=
N
BUS
344192
ON
=
=
=
P
=
=
M
=
N
BUS
344192
344192
ON
=
=
=
P
=
=
M
=
N
BUS
ON
=
=
=
P
=
=
M
=
N
BUS
To other apartments or
apartment interfaces
EXT
ON
346030
346850
INT
344192
ON
346841
OF F
OFF
=
=2
M =3
346030
PRI:
2 WIRE
building riser
PR I
ON
BUS
=
N
=
=
P
=
=
M
=
220 - 240V ~
185-175m A
50/60 Hz
SCS A- V
SCS
27Vd c
600m A
SCS A-V
SCS
NOTE: 5 handsets max. per apartment. AXOLUTE, Nighter/Whice, Video Station item 349320/21 handsets must be powered locally using item 346020.
WARNING
2 WIRE video EP
BUS PL S+ S-
Handset BUS
2 WIRE audio EP
BUS PL S+ S-
PS
BUS PI
2 WIRE video EP
BUS PL S+ S-
2 WIRE audio EP
Audio 1 EP
Audio 2 EP
BUS PL S+ SBUS PL S+ S-
Handset BUS
PS
BUS TK
BUS PI
OUT M
BUS TK
OUT M
BUS 2 1
M2
N2
J
PE
IN
5
1
5
1
6
2
6
2
7
3
7
3
8
4
OUT M
PS
BUS PI
M1
2
1
BUS TK
PRI
M1 N1 M2 N2
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
8
4
OU T
5
1
6
2
7
3
BUS 2 1
N1
NF
CEBEC
IP30
M2
8
4
346000
12 345678
N2
J
=
=
=
=
=
=
=
=
=
346150
JMP
12 3 45678
PE
IN
5
1
6
2
6
2
7
3
7
3
8
4
8
4
OUT M
PS
BUS PI
2
1
BUS TK
PRI
M1 N1 M2 N2
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
OU T
5
1
6
2
7
3
8 WIRE digital
system backbone
NF
CEBEC
IP30
8
4
346000
1 2345678
230 Vac
230 Vac
8 WIRE digital
system backbone
5
1
JM P
N1
346150
JMP
12 34567 8
JM P
M1
=
=
=
=
=
=
=
=
=
344824
344704
1
5
1
5
3
2
1
3
2
1
0
ET
BUS
BUS
ET
BUS
ET
BUS
344212
+
346800
1
5
ET
With ADVANCED handsets it is necessary to use the call to the floor on the BUS (see below).
APARTMENT 3
N = 12
N=3
346833
346833
=
P
=
=
N
=
MOD =
1
2
=
P
=
=
N
=
MOD =
BUS
BUS
BUS
BUS
Pushbutton
Pushbutton
344824
344824
344824
N=1
N=2
3
2
1
0
N=3
3
2
1
0
3
2
1
0
346833
BUS
BUS
BUS
BUS
Configuration to be used in one-family or multi-family systems after apartment interface item 346850.
Pushbutton
NOTE: The configuration of interface item 346833 with MOD=4 gives the
possibility of associating the video image of a camera to the call to the
floor generated by the pushbutton outside the door.
APARTMENT 5
APARTMENT 13
L4651M2
H4651M2
A
PL
M
SPE
AUX
=
=
=
=
=
5
2
7
344192
344192
ON
=
=
=
P
=
=
M
=
N
BUS
L4651M2
H4651M2
A
PL
M
SPE
AUX
OFF
=
=
=
P
=
=
M
=
N
BUS
1
3
BUS
BUS
=
=
=
=
=
1
3
2
7
BUS
EXAMPLE - Call to the floor on BUS - connection after the Handset. If the special control
is connected as the last of the riser or apartment line, it is necessary to install a terminator
item 3499 in IN-OUT on the control.
BUS C NO
BUS PL S+ S-
BUS PL S+ S-
* PS
BUS C NO
S
1
2
12 Vac
BUS C NO
BUS PL S+ S-
PS
PS
349140
Handset risers
230 Vac
OUT1
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
OUT3
OUT4
230 Vac
1 2 S+ ED S-
346000
NF
CEBEC
OUT2
F441
OUT
I NO U T 1
IP30
OUT2
OUT3
PRI
346230
346020
346230
OUT4
P T
1 2 S+ ED S-
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
OUT
BUS 2 1
CEBEC
IP30
IN1
IN3
IN2
IN4
346020
1- 2
PRI
346230
SCS
346020
BUS
IN
P T
1- 2
230 Vac
IN1
BUS 2 1
IN2
IN3
IN4
SCS
BUS
230 Vac
OPZIONALE
OPZIONALE
* NOTE: required for lines (EP - SCS power supply) > 50 m - (cable item 336904 )
346000
230 Vac
346020
1 2 S+ ED S-
346230
230 Vac
346230
PRI
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
NF
346020
PRI: 220 - 240V~
175A
50/60
165m z
H
127Vdc
600 A
2:
m
CEBEC
IP30
346230
1- 2
PRI
P T
1 2 S+ ED S-
SWITCH C9455
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
CEBEC
IP30
NF
BUS 2 1
346020
PRI: 220 - 240V~
175A
50/60
165m z
H
127Vdc
600 A
2:
m
230 Vac
1
DC - In
DC - In
Ethernet cable
1
1
349140
1- 2
P T
BUS 2 1
230 Vac
** NOTE: required for lines (EP - SCS power supply) > 50 m - (cable item 336904 ).
A
PL
M
SPE
AUX
X
BUS
=
=
=
=
=
1
7
BUS PI
P3
P2
P4
P1 = A/PL + 1
P2 = A/PL + 3
P3 = A/PL
P4 = A/PL + 2
=
=
=
N
=
T =
Entrance panel
346000
BUS PL S+ SN
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
BUS BUS
PI
TK
NF
CEBEC
IP30
PS
346830
BUS 2 1
230 Vac
Speaker module
Power supply
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
342170
346000
JMP 3
JMP 1
JMP 4
JMP 2
NF
CEBEC
IP30
BUS PL S+ S-
BUS 2 1
= disconnected jumper
230 Vac
= inserted jumper
PS
230 Vac
Auxiliary transformer
230 Vac
Speaker module
Power supply
PRI
PRI
BUS
346040
PRI 110 - 240 V 50 - 60 Hz 370 mA - 225 mA
BUS 26.0 V 600 mA
342150
BUS
BUS
346040
BUS C NO
PS
230 Vac
Auxiliary transformer
Handset BUS
346000
346250
8 A cos = 1
8 A cos = 0,7
8 A cos = 1
24 Vdc; 24 Vac
24 Vac
24 Vac
BUS
TK
BUS
PI
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
NF
CEBEC
IP30
PS
346830
NOTE: The safety door lock remains closed when voltage is present. It opens when the voltage is interrupted.
5
1
8
4
7
3
BUS
12 V ~
Actuator
MOD =
=
M
=
=
P/N
=
T =
12V
336842
230V
6 A max
346200
Actuator
MOD =
=
M
=
=
P/N
=
T =
NC C NO
5
1
6
2
7
3
346200
NC C NO
8
4
5
1
6
2
8
4
7
3
230 V ~
Power supply
346040
1
2
BUS
Power supply
346000
BUS
* PS
* PS
230 Vac
230 Vac
Auxiliary transformer
6 A max
12V
PL1-C336842
230V
NC C NO
S2
1 2 PL S+ S-
346230
346230
P=1
5
1
6
2
230 V ~
346040
BUS
346833
=
=
=
N
=
230 Vac =
MOD
=
PS
to video adapter
346830
P T
BUS
S1
Distance 346833 pushbutton = max. 3 m
S1 opening
pushbutton
BUS PL S+ SP=0
8
4
7
3
6 A max
S2 opening
pushbutton
Actuator 346260
346040 * Entrancehall door
lock
BUS BUS
pushbutton
346230 346230
J J
T M M MP
P P
18V 4A
18V 4A
S+ S-
S+S- = 18 V 4 A impulsive
250 mA holding current
(max. 30 Ohm)
J J
T M M M
P P
T= -5 +45CT= -5 +45C
IP 30
IP 30
J J J J
MM MM
P P P P
SCS
346230
SCS
J J
M M
P P
J J
M M
P P
J J J J
MM MM
P P P P
346260
346000 * Entrancehall
346040
door lock
BUS pushbutton
346000
346040
* Entrance-hall
door lock pushbutton
BUS
6A max
(res)
6A max (res)
1
2 PL
S+ S-
- TMP
Auxiliary
transformer
346230
PL RC
346230
C NC NO/S+ S-
ART. 346260
T= -5 +45C
IP 30
Vac
C NC NO/S+
C NC
S- NO/S+ S-
ART. 346260
ART. 346260
Vac
SCS
T M
346260
M=5
BUS TK
346000
346830
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
346200
BUS
PI
NF
CEBEC
IP30
PS
BUS 2 1
NC C NO
6
2
5
1
7
3
MOD =
=
M
=
=
P/N
=
T =
8
4
230 Vac
230 Vac
BUS PI
associated to
the Handset = 2
L4651m2
H4651M2
BUS
PE
A
PL
M
SPE
AUX
=
=
=
=
=
2
3
7
346000
346200
BUS
TK
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
BUS
PI
NF
CEBEC
IP30
PS
BUS 2 1
346830
NC C NO
5
1
6
2
7
3
MOD =
=
M
=
=
P/N
=
T =
8
4
230 Vac
230 Vac
The special control acts on the actuator item 346200
configured to switch on the light. For further information see
technical sheets of the special control and the actuator item
346200.
NOTE: in audio systems, the wiring of the special control can
occur in any point of the system.
MOD = 0
MOD = 1
MOD = 2
Staircase
light
PL2-C
346833
=
P
=
=
N
=
=
MOD
=
Staircase light
pushbutton
to EP
346000
346830
N
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
2 - 1 27V 1,2A
BUS BUS
PI
TK
NF
CEBEC
IP30
PS
BUS 2 1
346200
MOD =
=
M
=
=
P/N
=
T =
NC C NO
5
1
6
2
7
3
8
4
230 Vac
230 Vac
BUS
PE
346000
PRI
346000
PRI 230 V~ 50 - 60 Hz 260 mA
BUS 27V 1,2A
2-1
346200
346830
BUS
TK
BUS
PI
NF
CEBEC
IP30
PS
BUS PL S+ SP=1
BUS 2 1
NC C NO
5
1
BUS
6
2
7
3
MOD =
=
M
=
=
P/N
=
T =
8
4
230 Vac
230 Vac
Closing of contact upon reception of a call from the EP configured with P=1.