CSH & CSH-B

40 kA Horizontal Interrupter Circuit Switcher

MAXIMUM VOLTAGE RATINGS


38 kV to 170 kV

CONTINUOUS CURRENT RATINGS


1200 A, 1600 A, and 2000 A

PRIMARY FAULT INTERRUPTING RATING


25 kA, 31.5 kA, 40 kA
„ 15.5 kV – 72.5 kV
INTERRUPTING SPEED
5 Cycle
„ 1200 A & 1600 A Continuous Current
FAULT CLOSE RATING
„ 10
20Time
kA &4025kAkA Primary Fault Current
Interrupting
MAKES AND BREAKS CIRCUIT IN SF6 GAS
„ 5 Cycle Interrupting Speed
AVAILABLE WITH CMD THREE-PHASE
TM

NON-CONTACT CURRENT TRANSFORMER


„ 5 Time 25 kA Fault Closing
AVAILABLE WITH COMPOSITE INSULATORS
„ AND
Available with CMD
COMPOSITE TM
HOUSED INTERRUPTERS
Three-Phase Non-
Contact
Current Transformer

The Most Versatile And Capable Horizontal Interrupter Circuit


Switchers Available In The Marketplace Today

New Enhanced design! Now available in 25 kA, 31.5 kA, and


40 kA interrupting rating!
Southern States CSH and CSH-B, the industry’s only 5 cycle interrupting time, 40 kA
interrupting capability, horizontal interrupter circuit switchers, provide economical,
versatile, space saving solutions for fault protection and switching applications, including:
ƒ Power Transformer Switching and Protection
ƒ Capacitor Switching (Non-Transient Mitigating) and
Protection
ƒ Line or Cable Switching and Protection
ƒ Reactor Switching and Protection
ƒ Series Capacitor Bypassing

The Quality Name In High Voltage Switching


CSH & CSH-B
40 kA Horizontal Interrupter Circuit Switchers
Key Advantages:
„ Makes and breaks the circuit in SF6 gas
rather than in air Ratings
„ 5 cycle interrupting speed minimizes Maximum kV
38 48.3 72.5 123 145 170
system disturbance Rating
Interrupter/Blade
„ Puffer interrupters provide long contact 350/200 350/250 350 550 650 750
BIL (kV)
life and multi-time fault closing capability
Continuous
„ Single gap interrupters provide full BIL 1200 A, 1600 A, 2000 A for all kV ratings
Current
without the need for an integral
disconnect switch or voltage grading Primary Fault
25 kA, 31.5 kA, and 40 kA for all kV ratings
resistors/capacitors Interrupting
„ Simple, easy erection minimizes field
Interrupting Time 5 cycles
installation time required
„ Ships with minimal gas pressure for Number of Full
10 at 40 kA, 15 at 31.5kA, 30 at 25 kA
safety during transportation and in Fault Operations
handling during installation Fault Close 10 time 40 kA, 15 time 31.5 kA, 30 time 20 kA
Ratings for all kV ratings
„ Adaptable to a wide variety of mounting
positions, structure heights, and phase Ambient
-40º C to +50º C standard
spacings Temperature
-50º C to +50º C optional
„ Ideally suited to upgrade the fault Range
interrupting capability of existing
horizontal interrupter circuit switcher
installations, reusing the existing circuit
switcher’s structure and foundations
„ The only available 40 kA interrupting
capability, 5 cycle interrupting time,
makes-the-circuit-in-the-interrupter circuit
switcher available for mobile trailer
mounting
„ Available with CMD TM three-phase non-
contact current transformer (See catalog
flyer CF1501 for details.) which can be
integrally mounted on the CSH or on the
CSH-B to provide the CSH or the CSH-B
with current sensing capability and also
to allow the unprotected zone between
the circuit switcher and the power
transformer’s primary side bushings and
arresters to be protected
„ Southern States 5-year warranty
promises trouble-free operation

Southern States, LLC


30 Georgia Avenue
Note: For dimensional information Hampton, GA 30228
on the CSH and/or CSH-B please e-mail: sales@southernstatesLLC.com
phone: 770-946-4562
contact Southern States for fax: 770-946-8106
drawing(s) of the rating(s) of www.southernstatesLLC.com
The Quality Name In High Voltage Switching interest. www.ssipower.com

Publication No. CF803-40-010908• Printed in USA January, 2008 • © 2008 Southern States, LLC