Вы находитесь на странице: 1из 8

P30 Series

Portable Water Quality Meters

1/30

As low as
the power consumption
(compared to previous models)

Waterproof
Construction
1000 Data
Points Memory

P30 Series
Features 8meters
including
pH
dual channel ION
modes
ORP
DO
EC

Low Power Consumption & Waterproof


Construction Perfect for Field Measurements

Can use rechargeable


nickel-hydrogen batteries

Enables you to dramatically reduce battery waste.


( Rechargeable nickel - hydr ogen A A bat teries are sold
separately.)

Improved indicator that is easier to read


Dual channel meters that can display
two items simultaneously

The custom LCD indicators are 1.2 times larger


than previous models, making them easier to read.
Additionally, dual channel meters can display two
items simultaneously. This makes it easier to read
data for two separate items in real time.

1000 Data points memory capacity


Can specify auto memory at xed time intervals*

Ideal for brief (half day) simple monitoring, etc.

Superb expandabilityexcept HM-30PRM-30P


Can be connected to PCs, external printers,
recorders, and other devices

Short interval memory function: 1 sec. 99 min. 59 sec.,


or Long interval memory function: 2 min. 99 hr. 59 min.
(For the long interval memory function, the power goes
OFF [into sleep mode] after the rst minute measurement
and remains off until the next measurement is made.)

Desktop-level expandability allows you to manage


data easily.

Two year warranty for the main unit

Supporting functions for enhanced validation

(Sensors and other parts are not covered under


the warranty.)

Utilizing the concepts from previous models, we


have developed a number of functions essential
for measurement control, such as sensors with
built-in memory, calibration history, and calibration
interval warning function.

Lineup
pH

Please refer to the Specications & Function table for detailed


information about each model.

(If you want an electrode that is not tted as standard, please place separate orders for
the main unit only and the electrode you need.)

Temperature

Temperature

DO

Portable pH Meter

Portable DO Meter

Common type for


conducting pH measurements

Can be used to conduct


eld measurements of DO/BOD

Comes with the pH combination


electrode GST-2739C.

Comes with the immersion type DO


electrodeCal-memo (Calibration
Memo)OE-270AA.

DO-31P

HM-30P

Note : For conducting BOD


measurements, please place orders
for the main unit onlyand theDO electrode for the
DO electrode for the
incubator bottle OE-470AA.
incubator bottle

pH

ORP

ch1

Temperature

ch2

Portable pH Meter

HM-31P

Electrical
Conductivity

pH

Electrical
Resistivity

ORP

Salinity

Temperature

Temperature

Portable Electrical
Conductivity/pH Meter

High performance model that


can conduct pH or
ORP measurements

WM-32EP

High performance dual channel


type that can simultaneous display
electrical conductivity and pH

Comes with the pH combination


electrode Cal-memo (Calibration
Memo) GST-2729C.

Comes with the pH combination


electrodeCal-memo (Calibration
Memo)GST-2729C, and the
electrical conductivity cellCal-memo
(Calibration Memo) CT-27112B.

ORP electrode is sold separately.

c h D u al
an
t y p n el
e

The ORP electrode is sold separately.

ORP

Temperature

Portable ORP Meter

RM-30P

ch1

pH

ORP

Ion

Temperature

ch2

pH

ORP

Ion

Temperature

Portable Ion/pH Meter

IM-32P

Common type for


ORP measurement

High performance dual channel


type that can be used for
ion measurements

Comes with the ORP combination


electrode PST-2739C.

Comes with the pH combination


electrodeCal-memo (Calibration
Memo)GST-2729C.

c h D u al
an
t y p n el

The ORP electrode, ion electrode,


and ion standard solutions are sold
separately.
Electrical
Conductivity

Electrical
Resistivity

Salinity

Temperature
ch1

Portable Electrical
Conductivity Meter

ch2

CM-31P

DO
pH

Temperature
ORP

Temperature

Portable DO/pH Meter

DM-32P

Can be used general


environmental measurements as
well as pure water measurements

High performance dual channel


type that can simultaneous
display DO and pH

CM-31P

for general environmental measurements

Comes with the pH combination electrode


Cal-memo (Calibration Memo)GST-2729C,
and the immersion type DO electrodeCalmemo (Calibration Memo) OE-270AA.

Comes with the electrical conductivity


cellCal-memo (Calibration Memo)CT-27112B.

CM-31P-W

for pure water measurements

Comes with the electrical conductivity cellCal-memo (Calibration Memo)


CT-27111D for pure water, and special ow cell CEF-22A (made of PP).
Make sure to select the one that
best ts your needs.

Electrical conductivity cell


for pure water

Note : For conducting BOD measurements,


please place orders for themain unit only
and theDO electrode for the incubator
bottle OE-470AA.

c h D u al
an
t y p n el
e

LEA

Waterproof sensors perfect for eld measurement.


TheCal-memo (Calibration Memo)sensor has built-in memory
and is designed for validation support.

FREE SEN
D-

LEAD-FREE

R
SO

Full lineup of high-reliability


sensors for a variety of uses

Corresponding sensors
GST-2729C CT-57101B
GST-2739C CT-57101A
PST-2729C CT-57101C
PST-2739C

Can store calibration data and cell constants


Realizes advanced measurement control
Free of setting errors for cell constants and ion species

Our original built-in oat for monitoring the internal solution concentration
allows the user to instantly recognize when the solution needs to be replaced.
(pH/ORP)

Cal-memo

pH/ORP
Electrode

Use

pH combination electrode
General environment/
Cal-memo (Calibration Memo)
immersion
GST-2729C
Waterproof type

pH combination electrode General environment/


GST-2739C
immersion
Waterproof type

Measuring range Lead length


1mStandard
3m
pH014
0100
5m
11m
1mStandard
3m
pH014
0100
5m
11m

Remarks
Electrode with HM-31P/WM-32EP
tted as standard (Lead length: 1 m)
Approval of type by Measurement Law
Electrode with HM-30P tted as
standard
(Lead length: 1 m)
Approval of type by Measurement Law

pH combination electrode
Organic solventCal-memo (Calibration Memo)
containing solution
ELP-031

pH014
0100

1m

Approval of type by Measurement Law

pH combination electrode
Fluorinated acid
Cal-memo (Calibration Memo)
solution-resistance*1
ELP-040

pH212
050

1m

Replaceable type glass electrode tip


glass electrode tip (5082L)

General environment/
ORP combination electrode
Cal-memo (Calibration Memo) immersion
PST-2729C
Waterproof type

0
2000mV
0100

General environment/
immersion

0
2000mV
0100

ORP combination electrode


PST-2739C

Waterproof type

Product Name
Code number
pH4.01 standard solution, 500 mL
143F191
pH6.86 standard solution, 500 mL
143F192
pH9.18 standard solution, 500 mL
143F193
Reference electrode internal
solution, 50 mL (4 bottles)
RE-4-20
(3.3 mol/L KCl solution)
ORP check solution
(pH4.01 standard solution, 500 mL
143F196
+ quinhydron powder, 5 packs)
Abrasive for ORP electrode, 10mL
AO-001

1mStandard
5m
11m
1mStandard Electrode with RM-30P tted as
5m
standard
(Lead length: 1 m)
11m

1 The glass electrode is affected by uorinated acid solution. However, because this product is a replaceable type glass
electrode tip, a reduction in operating costs can be expected. In regards to measuring the 1% uorinated acid solution (at
25 , for 1 min.), approximately 1000 measurements can be performed.

Electrical Conductivity
Cell

Use

Meas.Range
(Cell Constant)

0.1mS/m
Electrical conductivity cell
General environment/
Cal-memo (Calibration Memo)
10S/m250m -1
immersion
CT-27112B
080
Waterproof type
pure water
Electrical conductivity cell
Cal-memo (Calibration Memo) measurement/
CT-27111D
ow-through type

5S/m
20mS/m1m -1
080
100S/m
Electrical conductivity cell
General environment/
Cal-memo (Calibration Memo)
10S/m100m -1
tabletop use
CT-57101B
0100
High electrical
1mS/m
Electrical conductivity cell
Cal-memo (Calibration Memo) conductivity/tabletop 100S/m
1000m -1
CT-57101A
use
0100
Low electrical
5S/m
Electrical conductivity cell
Cal-memo (Calibration Memo) conductivity/tabletop 1S/m10m -1
CT-57101C
use
0100

Lead
Remarks
Length
Standard
1m
Cell with CM-31P/WM-32EP tted as
5m
standard (Lead length: 1 m)
11m
Cell with CM-31P-W tted as standard
1m
<Flow cell sold separately.>*2
Note: Cannot be connected to WM-32EP.

Product Name
Electrical conductivity cell check solution,
C solution, 100 mL (4 bottles)
Electrical conductivity cell check solution,
B solution,250 mL (2 bottles)
Flow cell (made of PP)
Flow cell (made of SUS)

Code number
0BI00001
0BI00002
CEF-22A
CEF-23A

1m

1m

1m

Note: When you perform


measurements in pure water, you must
use CT-27111D.

2 If you order the full CM-31P-W set, a ow cell is also tted as standard.

DO
Electrode

Use

Measuring range
If a standard membrane is

DO electrode
General environment/ used:
Cal-memo (Calibration Memo)
020mg/L
immersion
OE-270AA
If a high concentration
Waterproof type
membrane is used:

050mg/L
DO electrode
General environment/ 050
Cal-memo (Calibration Memo)
immersion
(High concentration membrane
OE-570BA
Waterproof type
set is sold separately.)

DO electrode
Cal-memo (Calibration Memo) Incubator bottle
OE-470AA
DO electrode
Cal-memo (Calibration Memo) Incubator bottle
OE-470BA

Remarks
Electrode with DO-31P/DM32P tted as standard
(Lead length: 3 m)
Can be used to conduct zero
ow rate measurements

1m

Equipped with a stirring function.


(Recommended for conducting
BOD measurements)

1m

Can be used to conduct zero


ow rate measurements

020mg/L

Product Name

Code

Remarks

DO module

OEC-002

E xclusive to O E - 270A A One -touch fit ting t y pe featuring an integral


construction made up of an electrode, membrane, and electrolysis solution.

Membrane set for OE-270AA (3 sets)

0CC00001
0CC00002
0CC00023
0CC00024
0CC00003
OCT-2502
0CC00022
0SM00002
0BG00007
143A030

For OE-270AA (standard measurement)

Membrane set for OE-270AA (high concentration DO) (3 sets)


Membrane set for OE-570BA (3 sets)
Membrane set for OE-570BA (high concentration DO) (3 sets)
Membrane set for OE-470AA (3 sets)
Membrane cartridge for OE-470AA (5 pieces)
Membrane set for OE-470BA (3 sets)
Underwater stirrer
Electrolysis solution R-9, 50 mL (3 bottles)
Sodium sulte 50 g

Lead
3mStandard
5m
11m
3mStandard
5m
11m

For OE-270AA (high concentration measurement)


For OE-570BA (standard measurement)
For OE-570BA (high concentration measurement)
For OE-470AA (measurement)
For OE-470AA (measurement)
For OE-470BA (measurement)
For OE-270AA/570BA
For OE-270AA/570BA/470AA/470BA
Used for preparing zero solution

Ion

Cal-memo

The ion sensing portion is a replaceable tip (except membrane electrode).


Lead length is 1 m.

Notes: (1) The ion electrode is not provided for waterproof function and temperature measurement function. Measurable
solution temperature range is 0 50 .
(2) The batch measurement method is primarily used to conduct ion measurements. This method is conducted after
sampling, which uses beakers and other apparatuses.
(3) In addition to the electrode, the standard solution, ionic strength adjuster, and reference electrode external
solution are also required for conducting ion measurements.
(4) Make sure to contact us before you conduct ion measurements. We ask this because in certain cases it can be
difcult to conduct ion measurements, such as when there are coexisting ions in the sample.

Electrode name
Fluoride ion combination electrode
F-2021
Chloride ion combination electrode
CL-2021
Bromide ion combination electrode
BR-2021
Iodide ion combination electrode
I-2021
Cyanide ion combination electrode
CN-2021
Nitrate ion combination electrode
N-2031
Sulde ion combination electrode
S-2021
Sodium ion combination electrode
NA-2011
Potassium ion combination electrode
K-2031
Calcium ion combination electrode
CA-2031
Cadmium ion combination electrode
CD-2021
Copper ion combination electrode
CU-2021
Silver ion combination
electrodeAG-2021
Ammonia combination electrode
AE-2041
Carbon dioxide combination electrode
CE-2041

Model name of the


Measuring range
ion replacement tip
(optimal pH range)
F-200
0.01919,000mg/L F
Solid membrane pH56
CL-200B
135,000mg/L Cl
Solid membrane pH56
BR-200
0.880,000mg/L Br
Solid membrane pH56
I-200
0.01127,000mg/L I
Solid membrane pH56
CN-200B
0.00326mg/L CN
Solid membrane pH1213
N-300
0.6262,000mg/L NO3
Liquid membranepH56
S-200
0.332,000mg/L S2
Solid membrane pH13 or more
NA-100B
2.323,000mg/L Na+
Glass membranepH1011
K-300B
0.393,900mg/L K+
Liquid membranepH56
CA-300
0.440,000mg/L Ca2+
Liquid membranepH56
CD-200
0.011,120mg/L Cd2+
Solid membrane pH56
CU-200
0.06630mg/L Cu2+
Solid membrane pH56
AG-200
0.1108,000mg/L Ag+
Solid membrane pH56
0.091,800mg/L NH4+

pH12 or more

Dissolved gas
1.491,490mg/L

Effect of coexistent ion */Remarks


OH=101
HPO42
HCO3=103pH78
Cl
Br
I
NO3
SO42
S2O32=105
S2=Cannot coexist
CN
I=105 Br
S2O32=102 NO3
SO42
CO32
PO43
F=103
S2=Cannot coexist
CNI=104 S2O32SCN=100 Cl=102 NO3SO42CO32F=104
S2reducing substances=Cannot coexist CN=100
S2O32=101 SCN=103 Br=104 NO3
CO32
PO43
Cl
F=105
S2=Cannot coexist I=101 S2O32=101
Br=103 NO3
SO42
PO43=104 CO32
Cl
F=105
I=103 Br
NO2=100Cl=101
CH3COO
SO42
CO32
F=102

Mg2+
Ca2+
Zn2+
NH4+
K+
Li+=103
H+=102 NH4+=3102 Na+=2103 Li+=104
Pb2+
Zn2+=101Mn2+=102
Cu2+
Mg2+
Cd2+
Ba2+
Fe2+=103 Ni2+=104
Hg2+
Ag+
Cu2+=Cannot coexist
Pb2+
Fe3+=100Cr3+=102 Na+
K+
Mg2+
Ca2+
Zn2+
Al3+=105
Ag+
Hg2+=Cannot coexist
Fe3+=101 Al3+=101 Cr3+=102 Ni2+=103Na+
Mg2+
Ca2+=104
Hg2+=Cannot coexistMg2+=103
Ca2+
Cu2+
Pb2+
Cd2+
Zn2+=104 Na+
K+=106
Volatile amines
Dissolved gas : Volatile weak acidAirborne gas : Acid gas
Note : A cell for calibration (CGC-202L) and an adapter for calibration
(6791140K) sold separately.

Effect of coexistent ion (selectivity coefcient for 0.1 mol/L ion concentration)
If an ion coexists in the solution, it can cause data errors when measuring the targeted ion. The effects of the coexistent ion are shown here.
A selectivity coefcient of 10x means that if the solution contains a coexistent ion that is 10 times greater than the value of the targeted ion that is measured, an error occurs in which the
value of the targeted ion equals the coexistent ion value.
If the concentration level of the coexistent ion is high enough to affect the measured values, we recommend conducting pretreatment in order to prevent interference.

Product Name
Exchange liquid junction for ion sensor (10 pieces)
Exchange membrane for ammonia electrode (10 sheets)
Membrane cartridge for carbon dioxide gas electrode (4 pieces)
Calibration cell for carbon dioxide electrode
Calibration adapter

Code
0LF00001
AE-FILM
CTC-211
CGC-202L
6791140K

Remarks

KCl saturated solution, 100 mL

143F237

For the internal solutions of all ion combination electrodes (except AE /CE-2041).
Reference external solution for CA-2031 and I/S//F-2021.

RE-2 reference electrode external solution, 100 mL


RE-3 reference electrode external solution, 100 mL
Ammonia electrode internal solution, 50 mL (3 bottles)
Carbon dioxide electrode internal solution RE-11, 500 mL
Na standard solution NA-1000,
500 mL
Cl standard solution CL-1000,
500 mL
Br standard solution BR-1000,
500 mL
I standard solution I-1000,
500 mL
CN standard solution,
500 mL *Toxi
Cd standard solution CD-100,
500 mL
K standard solution K-1000,
500 mL
Ca standard solution CA-1000,
500 mL
NH4 standard solution NH4-1000, 500 mL
NH4-N standard solution NH4-N, 500 mL
NO3 standard solution NO3-1000, 500 mL
NO3-N standard solution NO3-N, 500 mL
F standard solution F-1000,
500 mL
F buffer standard solution F-10,
500 mL
F buffer standard solution F-100 500 mL
Carbon dioxide electrode calibration powder (10 packs)
Ionic strength adjuster ISA-NA,
500 mL
Ionic strength adjuster ISA-CL
500 mL
Ionic strength adjuster ISA-CN
500 mL
Ionic strength adjuster ISA-CU
500 mL
Ionic strength adjuster ISA-K
500 mL
Ionic strength adjuster ISA-CA
500 mL
Ionic strength adjuster TISAB-01 500 mL
Ionic strength adjuster TISAB-11 500 mL
Ionic strength adjuster ISA-NO
500 mL
Ionic strength adjuster ISA-NH
500 mL
Ionic strength adjuster ISA-CO
500 mL
Ionic strength adjuster ISA-S (powder) (10 packs)

143F238
143F239
0BG00005
143D042
143E031
143A281
143C483
143H091
CN-100
143B500
143B482
143B481
143A041
143A042
143C486
143C487
143F391
143F393
143F392
143D044
143A338
143A334
143A335
143A336
143A337
143A333
143A279
143A280
143A340
143A339
143D045
143A332

Reference external solution for NA-2011 and CL/BR/CN/CD/CU/AG/F-2021

For all ion combination electrodes (except AE/CE-2041)


For AE-2041
For CE-2041
For CE-2041
For CE-2041

Reference external solution for K/N-2031


For AE-2041
For CE-2041
For NA-2011. Na: 1000 mg/L
For CL-2021. Cl: 1000 mg/L
For BR-2021. Br: 1000 mg/L
For I-2021. I: 1000 mg/L
For CN-2021. CN: 100 mg/LHazardous Material
For CD-2021. Cd: 100 mg/L
For K-2031. K: 1000 mg/L
For CA-2031. Ca: 1000 mg/L
For AE-2041. NH4: 1000 mg/L
For AE-2041. NH4-N: 1000 mg/L
For N-2031. NO3: 1000 mg/L
For N-2031. NO3-N: 1000 mg/L
For F-2021. F: 1000 mg/L
For F-2021. F: 10 mg/L (for special use)
For F-2021. F: 10 mg/L (for special use)
For CE-2041.
For NA-2021.
For AG/CL/BR/I-2021.
For CN-2021.Hazardous Material
For CU/CD-2021.Hazardous Material
For K-2031.
For CA-2031.
For F-2021. For general purpose use.
For F-2021. For solutions that contain heavy metals.
For N-2031.
For AE-2041.Hazardous Material
For CE-2041.
For S-2021.

Note : We do not sell silver ion standard and sulde ion standard solutions. If you need these solutions, you must prepare yourself, following the steps listed in the instruction manual.
*Toxic : Exercise caution when handling.

Portable Water Quality Meters

P30 Series

Product Name

Portable pH
Meter

Portable
ORP Meter

Portable pH
Meter

Model Name

HM-30P

RM-30P

HM-31P

Portable Electrical
Conductivity Meter

Specication and Function Table


Portable DO
Portable Electrical
Portable
Portable
Meter
Conductivity/pH Meter Ion/pH Meter DO/pH Meter

For general environment

CM-31P

For pure water

DO-31P

WM-32EP

IM-32P

DM-32P

Membrane
type galvanic
cell method

pH : Glass electrode
method
Electrical conductivity :
AC two-electrode
method

DO

Electrical Conductivity

pH
ORPIon

DO

pH
ORP

pH
ORPIon

pH
ORP

CM-31P-W

Measuring
method

Glass
electrode
method

Platinum
electrode
method

pH

ORP

Custom LCD

Display
Sensor
Connection

ch1

pHORP

pH :
0.00-14.00
Temperature :
0-100.0

ORP :
0-2000mV
Temperature :
0-100.0

pH :
0.00-14.00
ORP :
0-2000mV
Temperature:
0-100.0

[If standard cell is used]


Electrical conductivity :
0.1mS/m-10S/m
Electrical resistivity :
0.1m-10km
Salinity (NaCl equivalent
from electrical conductivity) :
0-4.00%
Temperature : 0-80.0

pH : 0.00-14.00
[If standard
ORP : 0-2000mV
membrane is used]
Temperature :
DO :
0-100.0
pH : 0.00-14.00
0-20.00mg/L
ORP :
Saturation rate :
[If
standard
cell
is
used]
0- 2000mV
0-200%
Electrical conductivity :
Temperature :
Temperature :
0.1mS/m-10 S/m
0-100.0
0-50.0
Electrical resistivity : Ion :
[If cell for pure water is
0.1
m-10k
m
[If high
differs
used]
Salinity (NaCl equivalent
according to
Electrical conductivity : concentration
obtained by electrical
membrane
is
used]
the electrode
5S/m-20mS/m
conductivity) : 0-4.00%
DO :
that is used.
Electrical resistivity :
0-50.0mg/L
Temperature : 0-80.0 (Temperature
50m-182km
measuring function
Saturation rate :
is not provided.)
Temperature : 0-80.0 0-500%
If the cell for tabletop
use is used, the
Temperature :
measuring range differs
If the cell for tabletop
0-50.0
according to the cell
use is used, the measuring
range differs according to
the cell that is used.

Display Range

pH :
-2.00-16.00
Temperature :
-5-110.0C

ORP :
0-2200mV
Temperature :
-5-110.0

pH :
-2.00-16.00
ORP :
0-2200mV
Temperature :
-5-110.0

Electrical conductivity :
0-200.0S/m
0-2.000mS/m
0-20.00mS/m
0-200.0mS/m
0-2.000S/m
0-20.00S/m
0-200.0S/m
Electrical resistivity :
0.005-2.000m
0-20.00m
0-200.0m
0-2.000km
0-20.00km
0-200.0km
0-2.000Mm
0-20.00Mm
Salinity(NaCl) :
0-4.04%
Temperature :
-5-110.0

that is used.

[If standard
membrane is used]
DO :
0-22.00mg/L
Saturation rate :
0-220%

Electrical Conductivity/
Resistivity Unit
Switching

Repeatability
(Main unit)

Auto/manual

Can switch between SI Units


(S/m, m) and the previous
units (S/cm, cm).

pH : 0.02pH ORP : 2mV


Temperature : Temperature :
0.2
0.2

Electrical
conductivity :
0.5%FS
pH : 0.02pH Electrical
resistivity :
ORP : 2mV
Temperature : 0.5%FS
Salinity :
0.2
0.5%FS
Temperature :
0.2

Auto/manual

[If standard
membrane is used]
DO : 0.03mg/L
Saturation rate :
2%
[If high concentration
membrane is used]
DO : 0.2mg/L
Saturation rate :
2%
Temperature :
0.2

pH : 0.02pH
ORP : 2mV
Electrical
conductivity :
0.5%FS
Electrical
resistivity:
0.5%FS
Salinity : 0.5% FS
Temperature :
0.2

pH : 0.02pH
ORP : 2mV
[If standard
pH : 0.02 pH membrane is used]
ORP : 2 mV DO: 0.03mg/L
Ion : 0.5%FS Saturation rate : 2%
Temperature : [If high concentration
membrane is used]
0.2
DO : 0.2mg/L
Saturation rate : 2%
Temperature : 0.2

pH : Auto/Manual
Electrical Conductivity/
Resistivity :
Switch setting between
Auto/Manual/None

Auto/Manual Linear/pure water


Not applied to dual temperature
compensation
ORP

(For salinity and auto only)

Auto

Reference temperature :
25
Temperature coefcient
: 0-9.99%

Calibration

Capable of
three-point
calibration

Cell constant
calibration

Auto/Manual

Temperature
compensation method : Not applied to
ORP and ion
Linear method
Reference temperature :
25
Temperature coefcient
: 0-9.99%

pH :
Auto/Manual
DO : Auto

(optional setting)

(optional setting)

Capable of
three-point
calibration

pH :
-2.00-16.00
ORP :
0-2200mV
[If standard
membrane is used]
DO :
0-22.00mg/L
Saturation rate :
0-220%

Can switch between SI Units


(S/m, m) and the previous
units (S/cm, cm).

Temperature
compensation method :

[If high concentration


membrane is used]
DO:0-50.0mg/L
Saturation rate :
0-500%
Temperature :
0-50.0

(For salinity and auto only)

Auto/Manual

[If standard
membrane is used]
DO : 0-20.00mg/L
Saturation rate :
0-200%
Temperature :
0-50.0

differs according to the


cell that is used

Switch setting between


Auto/Manual/None

Temperature
Compensation

pH : -2.00-16.00
ORP : 0-2200mV
Electrical conductivity :
0-200.0S/m
0-2.000mS/m
0-20.00mS/m
0-200.0mS/m
0-2.000S/m
0-20.00S/m
0-200.0S/m
Electrical resistivity :
0.005-2.000m
0-20.00m
0-200.0m
0-2.000km
0-20.00km
0-200.0km
0-2.000Mm
0-20.00Mm
Salinity (NaCl) : 0-4.04%
Temperature : -5-110.0

pH : 0.00-14.00
ORP :
0-2000mV
Temperature :
0-100.0

pH :
-2.00-16.00
ORP :
[If high
0-2200 mV
concentration
Ion :
membrane is used]
0.0g/L-999 g/L [If high
DO :
0-55.0mg/L
Temperature : concentration
membrane is used]
-5-110.0
Saturation rate :
DO :
0-550%
0-55.0mg/L
Temperature :
Saturation rate :
-5-110.0
0-550%
* In regards to the
Temperature :
In regards to the range,
range, the electrical
-5-110.0
the electrical conductivity/
conductivity/resistivity
resistivity differs according
to the cell that is used.

Electrical Conductivity/
Resistivity Range Switching

pH : Glass
pH : Glass
electrode method
electrode method
DO : Membrane
Ion : Ion electrode
type galvanic cell
method
method

Custom LCD (simultaneous display of dual channel measured data)


Electrical Conductivity

ch2

Measuring
Range

pH : Glass
electrode method AC two-electrode
ORP : Platinum
method
electrode method

Zero/span
calibration

pH : Capable of three-point
pH/ion :
calibration
Capable of threeElectrical conductivity :
point calibration
Cell constant calibration

pH : Capable of threepoint calibration


DO : Zero/span
calibration

Product Name

Portable pH
Meter

Portable ORP
Meter

Portable pH
Meter

Model Name

HM-30P

RM-30P

HM-31P

Portable Electrical
Conductivity Meter

Portable DO
Meter

Portable Electrical
Conductivity/pH
Meter

DO-31P

WM-32EP

Portable ion/ Portable DO/


pH Meter
pH Meter

For general environment

CM-31P

For pure water

IM-32P

DM-32P

CM-31P-W

One-point calibration

Temperature Calibration
Correction function
(Called by Key Input)

Salinity correction
Atmospheric pressure
correction

(DO)
Salinity correction
Atmospheric pressure
correction

Data Memory

1000 data points

Auto Hold Function

Provided (Stability threshold : Fixed)

Clock Function

Provided (To be shown while conducting a measurement)

Interval Memory Function

Provided (Interval: The interval can be specied between 1 sec.-99 min. 59 sec. or 2 sec.-99hr. 59 min.)

Printing Function
RS-232C
Interface

Number of Outputs/
Items

Analog
Output

Connectable
Devices
Communication
Specications

Can connect the external printer EPS-P30 (option)

PC or external printer EPS-P30 (option)

ch1

ch2

Connecting Cable available


separately as an option

Output
Specications

Communication system: Start-stop synchronous method


Number of outputs : 2 Number of outputs : 3
Measured value Measured value,
and temperature temperature,
and range (only
for electrical
conductivity/
resistivity)

Electrical conductivity/
electrical resistivity/
pH : 700mV salinity :
(pH0-14)
0-1V FS
(each range)
ORP : 1 V
(0-2000mV) Range :
Temperature : 100mV/range
0-1V (0-100 ) Temperature :
0-1 V (0-100 )

Baud rate: 19,200 bps

Number of outputs : 2
Measured
value and
temperature

Character length: 8 bits

Number of outputs : 3
Measured value,
temperature,
and range (only
for electrical
conductivity/
resistivity)

Parity: None

Stop bit: 1 bit

Number of outputs : 2 Number of outputs : 2


Measured value Measured value
(not available
and temperature
for ion) and
temperature

Number of outputs : 2 Number of outputs : 2 Number of outputs : 2


Measured value Measured value (not available Measured value
and temperature for ion) and temperature
and temperature

pH : 700mV
(pH0-14)
ORP : 1V
DO/saturation (0-2000mV)
rate :
resistivity/
0-1V FS
salinity :
(each range)
0-1V FS
Temperature : (each range)
0-1 V (0-100 ) Range :
100 mV/range
Temperature :
0-1V (0-100 )

pH : 700mV
(pH0-14)
pH : 700mV ORP : 1V
(pH0-14)
(0-2000mV)
ORP : 1V
DO/saturation
(0-2000mV) rate :
Temperature : 0-1V FS
0-1V (0-100 ) (each range)
Temperature :
0-1V (0-100 )

Waterproof Construction

IP67 (Enabled if the sensor is connected and if the external I/O portions are masked) (Can be immersed in water for 1m and 30 min.)

Performance Compensation
Temperature/humidity

0-45C, 90% or below (no condensation)


AA alkaline battery/
nickel-hydrogen battery (2 pieces)

Power Source
Power Consumption

(If 3 volt battery is used)2

Battery Life

AA alkaline battery/nickel-hydrogen battery (2 pieces) or special AC adapter (6VA option)

Approx. 0.003W Approx. 0.003W Approx. 0.003W Approx. 0.009W

Approx. 0.014W

Approx. 2000hours Approx. 2000hours Approx. 2000hours

Approx. 400hours4

Approx. 600hours

Approx. 0.009W Approx. 0.004W


Approx. 600hours

Approx. 1500hours

Approx. 0.014W
Approx. 400hours4

Approx. 68 (w) x 35 (h) x 173 (d) mm

Outside Dimensions
Mass

Approx. 280g

(Including Batteries)

Approx. 300g

1) If the sample is earthed, make sure to use RS-232C and analog output in a insulated condition.
If you want to simultaneously (realtime) use RS-232C interface and analog output, you must have the special option cable. Please contact us for details.
2) The power consumption (consumption current) values shown are for when option devices (e.g. PC, printer) are not connected. If option devices are connected, the power consumption might
be approximately twice as high as the values shown, depending on the model.
3) Except for when the DO electrode with the stirring function is connected.

Standard Accessories
Product Name

Portable pH
Meter

Portable ORP
Meter

Portable pH
Meter

Model Name

HM-30P

RM-30P

HM-31P

Portable Electrical
Conductivity Meter

Portable DO
Meter

Portable Electrical
Conductivity/pH
Meter

Portable ion/
pH Meter

Portable DO/
pH Meter

DO-31P

WM-32EP

IM-32P

DM-32P

For general environment

CM-31P

For pure water

CM-31P-W

Only for customers


placing order for full set

Standard
Accessories

[CM-31P]
Electrical
Electrical
conductivity
conductivity cell
DO electrode
CT-27112B
cell
ORP
OE-270AA
pH combination
pH combination (Lead length : 1m)
pH combination
CT-27112B
combination
DO electrode
(Lead length : 3m)
electrode
electrode
electrode
(Lead length : 1m)
[CM-31P-W]
electrode
OE-270AA
GST-2739C
GST-2729C
GST-2729C
pH electrode
Electrical
PST-2739C
(Lead length : 3m) pH combination
(Lead length : 1m)
(Lead length : 1m) conductivity cell
(Lead length : 1m)
GST-2729C
(Lead length : 1m)
electrode
(Lead length : 1m)
CT-27111D
GST-2729C
Flow cell made of PP
(Lead length : 1m)
CEF-22A
pH4.01 standard
solution (100mL)

3.3 mol/L KCl


solution (50mL)

pH6.86 standard
solution (100mL)
3.3 mol/L-KCl
solution (50mL)
Polybeaker
(50mL) (3pieces)

Polybeaker
(50mL) (3pieces)

pH4.01 standard
solution (100mL)

pH4.01 standard
solution (100mL)

pH4.01 standard
solution (100mL)

pH4.01 standard
solution (100mL)

pH6.86 standard
solution (100mL)

pH6.86 standard
solution (100mL)

pH6.86 standard
solution (100mL)

pH6.86 standard
solution (100mL)

3.3 mol/L-KCl
solution (50mL)

3.3 mol/L-KCl
solution (50mL)

3.3 mol/L-KCl
solution (50mL)

3.3 mol/L-KCl
solution (50mL)

Polybeaker
(50mL) (3pieces)

Polybeaker
Polybeaker
Polybeaker
(50mL) (3pieces) (50mL) (3pieces) (50mL) (3pieces)

AA alkaline batteries (for initial operation) ( 2 pieces), hand strap, instruction manual

Options

Designed to t your needs, from the eld to the lab.

For managing data on PC


Product Name
RS-232C connecting cable

Code number
118N062

Remarks
For PC connection. Lead length: 2 m.

For connecting to a recorder or other devices


Product Name
Analog output cable

Code number
118N063

Remarks

External printer

Lead length: 1.5 m. Side terminal for connecting to external devices


(3 mmY terminal).
(This product cannot be used for HM-30P and RM-30P.)

For data recording


Product Name

Code number

External printer
(with connecting cable)

EPS-P30

Printer sheet (20 rolls)

P000119

Ink ribbon (1 piece)

0RD00001

Connecting cable for external

118N061

Remarks
Compact sized printer with chart width of approx. 60 mm.
Ordinary printing level is sufcient for long-term data storage
(Cannot connect to HM-30P and RM-30P.)

*You must have this cable in order to use an external printer


(EPS-G/EPS-R).

For laboratory use


Product Name

Code number

Remarks
Ask

AC adapter
Electrode stand
(with column and stopper)
Electrode holder

6948810K
0IB00001

This product cannot be used for DO electrode.

Electrode attachment (DP)

0IB00007

Standard electrode for all P30 series products.


(This product cannot be used for DO electrode.) For ELP-040.

Electrode attachment(G)

0IB00004

For sensors that are for tabletop use.

Electrode stand/
holder/attachment

*Please prepare an electrode stand, an electrode holder, and an electrode attachment.

Carrying case

For eld measurement


Product Name

Code number

Stick holder

0IB00009

Twin stick holder

0IB00010

Anchor (AN-21P)

0IC00001

Rope for AN-21P


Carrying case
Soft case

Remarks
This product provides a lead length of 5 m or more for waterproof
sensors that are immersed.
If you have trouble reaching a measurement point, you use this
product to safely measure from a position that is more accessible.
This product provides a lead length of 5 m or more for waterproof
sensors that are immersed.
Two sensors can be attached.

Can be used for waterproof sensors that are immersed. Anchor for
submerging.
1SUS rope
0IZ00002
This case allows you to store and carry the main unit, sensor, and
0DA00001 other accessories, such as the standard solution.
(comes with shoulder belt)
This portable soft case allows you to store the main unit when it is
SC-10P
connected to a sensor.

Soft case

Issued on 10/11/2009

A-1-20E

Вам также может понравиться