Safetran
AIR GAP ARRESTERS
CLEARVIEW , HEAVY DUTY CLEARVIEW, HEAVY DUTY, CLEAR-COMM

Clearview

Heavy Duty Clearview

Clear-Comm

Heavy Duty

The Clearview Lightning Arrester is an air gap type with 16 discharge point electrodes. It has a large safety
factor against shorting due to this open toothed construction. It operates on 0-50 VDC for use on all low
voltage signal circuits and 0-175 VAC for 115 VAC power circuits. The Clearview has a consistent breakdown
voltage of 700-1000 volts. The Clearview is composed of a discharge unit, with the CLEARVIEW stamped in
one of the mounting clips for identification, and clear plastic cap.
The Heavy Duty Clearview Lightning Arrester is described on page H-1-3.
The Heavy Duty Lightning Arrester is a full air gap type for use on track circuits or where extremely high surge
currents are experienced. It operates on 0-50 VDC for use on all low voltage signal circuits and 0-175 VAC for
115 VAC power circuits. The Heavy Duty has a consistent breakdown voltage of 700-1000 volts. The Heavy
Duty is composed of a discharge unit with circular rather than point discharge electroides, with the name H.D.
ARRESTER stamped in one of the mounting clips for identification, and clear plastic cap.
The Clear-Comm Lightning Arrester is an air gap type with 16 discharge point electrodes designed to be used
with communications circuits. It operates on either 0-30 VDC or 0-100 VAC. The Clear-Comm has a consistent
breakdown voltage of 400-700 volts. The Clear-Comm is composed of a discharge unit, with the name CLEARCOMM stamped in one of the mounting clips for identification, and clear plastic cap.
All four types of arresters have standard mounting centers of 2-3/8 inches. They also meet or exceed
all applicable AREMA recommended practices.
3-01

Surge
Protection

H-1-2

CLEARVIEW LIGHTNING ARRESTER

Clearview
Lightning Arrester

Clearview Lightning Arrester


on 3 Post Porcelain Base

Clearview Lightning
Arrester
on Bakelite Base

Clearview Lightning Arrester


on Porcelain Base

ORDERING INFORMATION
To order, specify description and part number.

Description
Clearview Lightning Arrester
Clearview Lightning Arrester mounted on Bakelite base
Clearview Lightning Arrester mounted on Porcelain base
Clearview Lightning Arrester on 3 post Porcelain base
Dual Clearview Lightning Arrester on Porcelain base
Discharge Unit Only, Clearview Lightning Arrester
Protective Cap
3-01

Part Number
022485-28X
022485-31X
022485-32X
022485-33X
022485-71X
022485-36X
022485-20

H-1-3

HEAVY DUTY CLEARVIEW


LIGHTNING ARRESTER
HIGHER SURGE CURRENT
CAPABILITY
GREATER SURGE DISSIPATING
CAPABILITY
EXCEEDS ALL APPLICABLE
AREMA RECOMMENDED PRACTICES

The Heavy Duty Clearview Lightning Arrester is an air gap type with 16 discharge point electrodes. It has a
safety factor against shorting due to this open toothed construction. Though similar to the Safetran Clearview
Arrester, the discharge point electrode is machined from bar stock as it is on the Safetran heavy Duty
Arrester. This provides a higher surge current capability than the Clearview, while retaining the same open
construction to avoid shorting.
The Heavy Duty Clearview Arrester is designed as a primary arrester for all signal circuits where extremely
high surge currents are likely to be experienced. However, for severe surge conditions on track circuits, the
Safetran Heavy Duty Arrester provides even greater surge dissipating capability.
As with all Safetran air gap signal arresters, the Heavy Duty Clearview is designed for low voltage signal
circuits of 0-50 volts dc or signal and power circuits of 0-175 volts ac. It has a consistent breakdown voltage
of 700-1000 volts. Discharge current is conservatively rated at 50,000 amps.
The arrester has a clear plastic cap for checking surge activity without cap removal. However, the cap is
easily removable for closer inspection. Mounting centers are 2-3/8 inches for standard AREMA stud type
terminals.
The Heavy Duty Clearview Arrester meets or exceeds all applicable AREMA recommended practices.

ORDERING INFORMATION
To order, specify description and part number.
Description
Heavy Duty Clearview
Heavy Duty Clearview with Bakelite base
Heavy Duty Clearview with Porcelain base
Heavy Duty Clearview with 3 Terminal base

Part Number
022585-1X
022585-3X
022585-4X
022585-5X
3-01

H-1-4

HEAVY DUTY LIGHTNING ARRESTER

Heavy Duty Lightning Arrester

Heavy Duty Lightning Arreser


on Porcelain Base

Heavy Duty Lightning Arrester


on Bakelite Base

Heavy Duty Lightning Arrester


on 3 Post Porcelain Base

ORDERING INFORMATION
To order, specify description and part number.
Description
Heavy Duty Lightning Arrester
Heavy Duty Lightning Arrester on Bakelite base
Heavy Duty Lightning Arrester on Porcelain base
Heavy Duty Lightning Arrester on 3 post Porcelain base
Discharge Unit Only
Protective Cap

3-01

Part Number
022615-1X
022615-2X
022615-3X
022615-4X
022615-5X
022485-20