Академический Документы
Профессиональный Документы
Культура Документы
6-40 GHz
Split Architecture High Capacity Point to Point Microwave Backhaul System
User Manual
Revision1.3
Notice
ThisdocumentcontainsinformationthatisconfidentialandproprietarytoTrango
Systems,Inc.Nopartofthecontentofthispublicationmaybereproduced,modified,
used,copied,disclosed,conveyed,ordistributedtoanypartyinanymannerwhatsoever
withoutpriorwrittenauthorizationfromTrangoSystems,Inc.Thisdocumentisprovided
asis,withoutwarrantyofanykind.
Trademarks
TrangoSystems,TrangoLINK,andTrangoLINKGigaareregisteredtrademarksof
TrangoSystems,Inc.Othernamesmentionedinthispublicationareownedbytheir
respectiveholders.
StatementofConditions
Theinformationcontainedinthisdocumentissubjecttochangewithoutnotice.Trango
Systems,Inc.shallnotbeliableforerrorscontainedhereinorforincidentalor
consequentialdamageinconnectionwiththefurnishing,performance,oruseofthis
documentorequipmentsuppliedwithit.
InformationtoUser
Anychangesormodificationsofequipmentnotexpresslyapprovedbythe
manufacturercouldvoidtheusersauthoritytooperatetheequipmentandthe
warrantyforsuchequipment.
TrangoSystems,Inc.
14118StoweDrive,SuiteB
Poway,CA92064
Tel.:+1(858)3910010
Fax:+1(858)3910020
Copyright2011byTrangoSystems,Inc.Allrightsreserved.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
Contents
Tables ..................................................................................................... 9
Figures ................................................................................................. 10
Revision History .................................................................................. 13
Preface ................................................................................................. 14
Reference conventions ....................................................................... 15
Warranty Information .......................................................................... 15
Contacting Trango Technical Support .............................................. 15
Standards Compliance........................................................................ 16
1.0
Overview ............................................................................................................ 17
Ports and Indicators Indoor Unit ...................................................................... 19
Location of Serial No. and Out of Band MAC address........................................ 22
Ports and Indicators Outdoor Unit ................................................................... 22
Antenna Connection ........................................................................................... 24
Remote Mounting ............................................................................................... 24
Combiners for Antenna Sharing ......................................................................... 24
Power Supply ..................................................................................................... 25
Key Features ...................................................................................................... 26
Flexible Interfaces and Form Factor ................................................................... 26
Traffic Capacity................................................................................................... 26
Industry Leading System Gain............................................................................ 27
Full Licensed band frequency and T/R spacing support ..................................... 28
Channel Sizes from 3.5 MHz to 80 MHz ............................................................. 29
Adaptive Coding and Modulation ........................................................................ 29
Link Protection through 1+1 Hot Standby ........................................................... 30
2.0
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
3.0
4.0
Overview ............................................................................................................ 48
Graphical User Interface (Web Browser) ............................................................ 49
Command Line Interface (CLI) using SSH, Telnet or Console ........................... 52
Changing Password ...................................................................................... 54
Console Port ................................................................................................. 54
Simple Network Management Protocol (SNMP) ................................................. 55
Common Objects for Monitoring and Control ................................................ 56
Firmware Upgrade .............................................................................................. 57
Upgrade Procedure -TFTP ............................................................................ 58
Upgrade Procedure -FTP .............................................................................. 60
Capacity Upgrades ............................................................................................. 62
5.0
6.0
Installation .................................................................................. 64
Safety ................................................................................................................. 64
Installation Process ............................................................................................ 67
Preparing for Installation ..................................................................................... 67
Tools ................................................................................................................... 67
Grounding Overview ........................................................................................... 68
Power Supply Installation ................................................................................... 69
Antenna Installation ............................................................................................ 70
Install the IDU ..................................................................................................... 70
Connecting power............................................................................................... 71
Ferrite Installation .......................................................................................... 72
1+1 Hot Standby IDU Installation ....................................................................... 73
HP ODU Installation on Antenna ........................................................................ 74
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
7.0
8.0
GigaPlusUserManualRev1.3
MSE is too high and/or bit errors are showing when running linktest ............... 114
Receive Signal Level is too low ........................................................................ 115
RF Link is good but packet loss is occurring: ................................................... 116
No direct management using Out of band port ................................................. 116
No Radio Management connection over the link .............................................. 117
T1/E1 Ports not passing traffic.......................................................................... 117
GigaPlusUserManualRev1.3
GigaPlusUserManualRev1.3
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
Tables
Table 1: TrangoLINK GigaPlus part numbers ........................................................ 14
Table 2 Combiner Cross Reference......................................................................... 25
Table 3 GigaPlus Band and T/R Spacing Options .................................................. 28
Table 4 MSE Expected and Maximum Values ......................................................... 32
Table 5 ACM Threshold Table ................................................................................. 34
Table 6 Max Link Capacity (Mbps) for non-ACM Speed Settings ............................ 36
Table 7 Maximum Set Power Levels by Band and Modulation ................................ 38
Table 8 Minimum TX set power by band.................................................................. 38
Table 9 Max Receive Level Input ............................................................................. 39
Table 10 Failover Events ......................................................................................... 42
Table 11 Default Login Passwords .......................................................................... 49
Table 12 Recommended Torque ............................................................................. 70
Table 13 RSSI to Voltage Conversion ................................................................... 106
Table 14 T1/E1 Cable Wiring ................................................................................. 189
Table 15 Console Cable Pin-outs .......................................................................... 190
Table 16 Alarm Port Pin Functions ........................................................................ 191
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
Figures
Figure 1 IDU Functional Block Diagram ................................................................... 17
Figure 2 ODU Functional Block Diagram ................................................................. 18
Figure 3 Front Panel of GigaPLUS IDU ................................................................... 19
Figure 4 Side of IDU (Shows where MAC address can be found) ........................... 22
Figure 5 Outdoor Unit Connectors/Indicators (HP Model)........................................ 22
Figure 6 Polarization Indicator ................................................................................. 23
Figure 7 ODU Label ................................................................................................. 24
Figure 8 LDPC vs. Reed-Solomon ........................................................................... 27
Figure 9 Adaptive Coding and Modulation (ACM) .................................................... 29
Figure 10 1+0 Setup ................................................................................................ 40
Figure 11 1+1 Setup ................................................................................................ 41
Figure 12 Web Browser Login ................................................................................. 49
Figure 13 System Info Page .................................................................................... 50
Figure 14 Console Port Setting ................................................................................ 55
Figure 15 Windows Start & Telnet ........................................................................... 58
Figure 16 Capacity Upgrade in Link Setup Page ..................................................... 62
Figure 17 Site Based Grounding Diagram ............................................................... 68
Figure 18 IDU with Rack Ears installed .................................................................... 70
Figure 19 Power Connection on Front Panel ........................................................... 71
Figure 20 -48 VDC Power Connector Wiring ........................................................... 71
Figure 21 Ferrite ...................................................................................................... 72
Figure 22 Ferrite Installed ........................................................................................ 72
Figure 23 1+1 Hot Standby (IDUs) with CBLDAT-RIU3 ........................................... 73
Figure 24 Antenna to HP ODU Slip Fit Waveguide connection ............................... 74
Figure 25 Polarization Indication .............................................................................. 75
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
10
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
11
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
12
RevisionHistory
Revision
1.0
1.3
Revision Date
22 Apr 2010
6 June 2011
Description
Initial Release
Update to new format and add detail on new features in SW V 1.3
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
13
Preface
ThismanualcoversthebasicconfigurationandinstallationoftheTrangoLINKGigaPlus
licensedmicrowavebackhaulsystem,
Thisdocumentisintendedtoinstructandassistpersonnelintheoperation,installation
andmaintenanceoftheTrangolinkGigaPlusmicrowavebackhaulsystemandrelated
accessoriesshowninTable1.
Itisrecommendedthatallpersonnelengagedinsuchactivitiesbeproperlytrained.
TrangoSystemsdisclaimsallliabilitywhatsoever,impliedorexpress,foranyriskof
damage,lossorreductioninsystemperformancearisingdirectlyorindirectlyoutofthe
failureofthecustomer,oranyoneactingonthecustomer'sbehalf,toabidebythe
instructions,systemparameters,orrecommendationsmadeinthisdocument.
Part Number
Description
GigaPLUSIDU1
TrangoLINKGigaPLUSIndoorUnit,100MbpsFullDuplex,rack
mount(AllFrequencyVersions)ANSI/ETSI
HPXXYYYYZZ
TrangoLINKHighPower(HP)OutdoorUnit,640GHz
HP2XXYYYYZZ
TrangoLINKHighPower(HP2)OutdoorUnit,640GHz
PSUPPLYDT48
CBLDAT3
CBLDATRIU3
CBLDATRSSI
GigaPlusKEY1
GigaPlusKEY2
SFPGigEC
SFPGigES
SFPGigEM
48VoltUniversalDesktopPowerSupply
SerialConsoleCableforGigPlus
1+1HotStandbyCableforGigaPlus
BNCMtoBananaplugcableforRSSIvoltagemeasurement
SoftwareKeytoAllowThroughputsupto200Mbps
SoftwareKeytoAllowThroughputsupto375Mbps
SFP1000BaseTCopperRJ45
SFPFiberSingleModeModule
SFPFiberMultiMode
Table1:TrangoLINKGigaPluspartnumbers
Specificpartnumbersforradiounitsubbandsandbandspecificaccessoriessuchas
antennas,combinersandremotemountscanbefoundinAppendixE.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
14
Referenceconventions
Thisdocumentutilizesseveralconventions.
Allsystemcommandreferencesareshowninbolditalics.
Allreferencestoexternalpublicationsareshowninbold.
WarrantyInformation
TrangoLINKGigaPlusunitspurchasedfromTrangoSystems,Inc.arewarrantedfortwo
yearsfromdateofpurchase.Pleaseseewww.trangosys.comforacompletedescription
ofwarrantycoverageandlimitations.
ExtendedwarrantyprotectioncanbepurchasedthroughTrangoSalesorCustomer
Service(+18583910010).
ContactingTrangoTechnicalSupport
ShouldassistanceberequiredoranRMAberequired,youmaycontactthetechnical
supportdepartmentusingthefollowingmethods:
Address:
TrangoSystems,Inc.
14118StoweDr
SuiteB
Poway,CA,92064
USA
Phone:(858)3910010from8amto5pmPacificStandardTime.
Email:techsupport@trangosys.com
Web:www.trangosys.com
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
15
StandardsCompliance
FederalCommunicationsCommission(FCC)
ANSImodelsoftheTrangoLINKGigaPlusproductlinehavebeentestedandfoundto
complywiththefollowingFCCstandards:
CFR47Part15
CFR47Part101
AppendixEshowsthespecificpartnumbersthathavebeentested.
FederalCommunicationsCommission(FCC)EmissionDesignators
10M0D7Wfor10MHzBWratesandallmodulations
20M0D7Wfor20MHzBWratesandallmodulations
30M0D7Wfor27.5/28/30MHzBWratesandallmodulations
40M0D7Wfor40MHzBWratesandallmodulations
50M0D7Wfor50MHzBWratesandallmodulations
56M0D7Wfor55/56/80MHzBWratesandallmodulations
EuropeanTelecommunicationsStandardsInstitute(ETSI)
ETSImodelsoftheTrangoLINKGigaPlusproductlinehavebeentestedandfoundto
complywiththeEuropeanTelecommunicationsStandards:
EN30221721V1.2.1(200702)
EN30221722V1.2.2(200704)
EN3014891V1.8.1(200804)
EN3014894V1.4.1(200809)
EN609501,EN6095022
ThesestandardscoveralltheessentialrequirementsofDirective1999/5/EC.AppendixE
showsthespecificpartnumbersthathavebeentested.
RoHSCompliance
TheTrangoLINKGigaPlusproductlinecomplieswiththeEuropeanUnion(EU)
Directive2002/95/EContheRestrictionofHazardousSubstances(RoHS).
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
16
1.0 ProductDescription
Overview
TheTrangoLINKGigaPlusisahighperformancesplitarchitecturepointtopoint
wirelessmicrowavesystemdesignedforCarrier,Enterprise,andServiceProvider
networksusingthe640GHzlicensedspectrum.Thesystemprovidesafullduplex
wirelessLayer2Ethernetconnectionwithultralowpacketlatencyandjitter,and
supportsuptofour10/100/1000BaseT,twoEthernetFiberinterfaces,andeightT1/E1
interfacesfortimingorlegacyTDMsupport.
GigaPluswascreatedtoallowthehighestperformancepossibleacrossallstandard
frequencybandsandTRspacings.Eachendofthelinkconsistsofonecompactrack
width,1RUhighIndoorUnit(IDU)andoneOutdoorRFunit(ODU),connectedviaa
singlecoaxialcableupto1000feetlong.Figures1and2showthefunctionalblock
diagramofthesystemastheyaredividedbetweentheIDUandODU.
Figure1IDUFunctionalBlockDiagram
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
17
Figure2ODUFunctionalBlockDiagram
TheTrangoLINKGigaPlusisaFrequencyDivisionDuplex(FDD)radiowhichprovideslow
latencyoflessthan150microseconds(s),over1millionpacketspersecond,andupto
375Mbpsoffullduplexcapacity.StandardfeaturesincludeQualityofService(QoS)
trafficprioritizationtoensurethatcriticaltrafficgetsthrough,aswellasAdaptive
CodingandModulation(ACM)toimproveperformanceduringweatherrelatedsignal
degradation.
GigaPlussupportsdirect48VoltDCdualpowertoallowforredundantpowersupplies.
TheIDUpowerinputhasreversevoltageprotectiontopreventdamageandsurge
suppressioncircuitrytoreducesusceptibilitytonoise.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
18
PortsandIndicatorsIndoorUnit
TheFigurebelowshowsthevariousportsontheGigaPlusIDU.
Figure3FrontPanelofGigaPLUSIDU
TheTrangoLINKGigaPLUSfrontpanelinterfaceisdescribedbelow:
NTypeConnector(ODU):TheNTypeConnectorconnectstheIDUtotheODUthrough
coaxialcable.ThisportcarriesthetransmitandreceiveIFfrequencies,theODUcontrol
signal,andthe48VDCpowertotheODUonthecenterconductor.NMaletoNMale
cableterminationsarerequiredandLMR400isrecommendedformostinstallations.
GroundLug:Allowsforpropergroundingofthechassistotherack,whichisearth
grounded.
ODUStatusLEDs(2):TopLEDprovidesODUpower/PLLlockstatuswhilethebottom
LEDprovidesRFlinkstatus.IfthetopLEDisamber,theODUisnotpoweredon,not
connected,oroneofthePhaseLockedLoops(PLLs)intheODUisfaulty.Ifthebottom
LEDisamber,RFlinkisnotestablished.IfthelinkisestablishedbothLEDswillbegreen.
DualPowerConnector:Thisisathreepinpluggableterminalblock.TheIDUispowered
bya48Vpowersupply(notincluded).TheGigaPLUSIDUdoessupporttheuseoftwo
powersuppliesforpowerredundancy.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
19
USINGTWOPOWERSUPPLIESFORREDUNDANCY
Thepositive(+)groundwireonbothpowersuppliesshouldbeconnectedtothecenterpinof
thethreepinpluggableterminalblock.Onenegativewirefromthefirstpowersupplyshould
beconnectedtotheleftpinwhiletheothernegativewireofthesecondpowersupplyshould
beconnectedtotherightpin.
FUSING
TheIDUcontainstworesettablefusesthatwillautomaticallyopentheifthecurrentdraw
becomestoohigh,asinashortcircuitcondition.OnefuseisfortheODUNConnector,and
theotherisfortheIDUmainchassiscircuitry.Circuitheatingtriggerstheopening,sothefuse
willresetitselfafteritcoolsdown.Ifthereisarealfaultthefusewillopenagainandthe
problemmustbediagnosed.Thefuseisratedfor1.1ampsmaximumandwillopenwith1.6
orgreaterampscurrentflowing.
T1/E1ports(18):StandardRJ45connectorsbreakoutalltheT1/E1portsinto8RJ45
120Ohmconnectors.
RSSI/PDHLEDs:
RSSIOperation:Bydefault,theIDUdisplaystheactualODUReceiveSignal
StrengthbyilluminatingtheLEDsthat,whenaddedtogether,giveathenegative
dBmindicationoftheReceivedSignalStrength.
Example:LEDs4010and1onlyilluminatedindicatesanRSSIof51dBm
sincethesumoftheLEDvaluesis51.
PDHOperation:Viasoftwarecommand,theLEDscanbemultiplexedtodisplay
theconnectionstatusoftheT1/E1circuit.Thearrowsindicatetheupper(Arrow
pointingup)orlower(arrowpointingdown)portabovetheindicator.
ManagementPorts(RJ4510/100BaseTAutosensing/Autonegotiating):Foroutof
bandWeb,SNMP,Telnet,andSSHmanagement.
RedundancyPort:ConnectthisporttothehotstandbyIDUusingtheredundancy
cable.Note:ThisportisnotastandardEthernetPortandwillnotfunctionusinga
standardEthernetcable.CBLDATRIU3isrequired(optional)
SerialConsolePort(DB9male):1serialRS232portusedtomanageunit.
Alarms(DB9female):Thereare2alarminputswhichareCMOSlevelandareuser
configurable.Thereare2outputswhicharedrycontactratedfor50Volt1Ampseach.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
20
ModeSwitch:TheModeswitchoperatesasfollows:
1) Holdformorethan2seconds,butlessthan6seconds,theunitwill:
a. TheIPaddresswillberesettodefaulttoallowaccessintheeventofa
forgottenpasswordorIPaddress.
b. TheCLImanagementpasswordswillberesettodefault
c. TheWebinterfacepasswordswillberesettodefault.
d. TheSNMPread/write/trapcommunitystringswillbesettodefaults.
e. TheCLIpromptwillbereset.
2) Holdformorethan6seconds:Theunitwillresetthesystemconfigurationto
thefactorydefault,butNOTresettheitemsit(1)above.TheunitWILLREBOOT
automatically.
RESET:RebootsIDUwithoutdisconnectingthepowersupply.
2xGigEports:ETH1andETH2portsarebothRJ4510/100/1000BaseTautosensing
GigEports.
2xSFPPort:ETH3andETH4SFPPortssupporttwoadditionalnative1000BaseTorLC
fiberEthernetconnectionfortraffic.SFPmodulesareavailabletosupporteachas
follows:
a. SFPGigECCopperRJ45moduletosupport1000BaseT
b. SFPGigESSingleModeFiberforlonghaul
c. SFPGigEMMultimodeFiberforshorthaul
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
21
LocationofSerialNo.andOutofBandMACaddress
Figure4SideofIDU(ShowswhereMACaddresscanbefound)
PortsandIndicatorsOutdoorUnit
TheFigurebelowshowsthevariousportsontheGigaPlusHPODU.TheHP2ODUhas
thesameports.
NFemaleIF
Connector
RSSIVoltage
BNCF
AirPressure
Vent
GroundLug
Figure5OutdoorUnitConnectors/Indicators(HPModel)
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
22
GoreTMAirVentTheairventispresenttoprovidepressureequalizationathigh
altitudeswhilepreventingmoisturefromenteringtheunit.Nooperatorinteractionis
necessary.
DONOTTAMPERwiththeAirVent.Itshouldnotbetwistedorremoved.Tampering
withordamagingtheProtectiveVentwillvoidthefactorywarranty.
RSSIVoltageBNCFConnectorThisconnectorisprovidedtoalloweasyantenna
alignmentwhenusedwithamultimeterandtheCBLDATRSSIcable.TheVoltage
presentontheconnectorisdirectlyproportionaltotheReceivedSignalStrengthinthe
receiversectionoftheGigaPlus.
MountingLatchesFourlatchesareprovidedtoalloweasyattachmentoftheGigaPlus
tothestandardantennas,combinersandremotemounts.Twoofthelatcheshave
keyholestoallowlockingtheunittodetertheftand/orsecuretheunit.
PolarizationIndicatorsTheletterVandanarrowarediecastontheODUhousing
perimetertoassistinmountingtheODUtotheantennainthecorrectpolarization.If
thearrowispointedupanddown(asshown)theODUisalignedforvertical
polarization.Ifthearrowispointedleftorrightthenhorizontalpolarizationisbeing
used.
Polarization
indicator
Figure6PolarizationIndicator
GroundingLugODUThegroundlugprovidedontheODUshouldbeconnectedto
thetower/structurelegperthegroundingsectionrecommendations.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
23
LabelsTheSerialnumbers,model,andregulatorycomplianceinformationareshown
ontheODUlabelsattachedtotheODUexterior.
Figure7ODULabel
AntennaConnection
TheODUportionoftheGigaPlusutilizesaslipfitconnectionthatmakesinstallation
simple.TheODUsarealldesignedtomounttoacircularwaveguideantennaor
combinerwiththeexceptionofthe6GHzmodels,whichrequirearectangular
waveguideantenna.For7to40GHzmodels,simplyrotatingtheODUwillchangethe
antennapolarizationbeingused.Acompatibilitylistofantennasisprovidedin
AppendixE.
RemoteMounting
WhenusingtheGigaPlusHPODUswithantennasthatusearectangularwaveguide
interfaceinsteadoftheslipfitcircularwaveguide,aRemoteMountplusflexwaveguide
willberequired.ThecompatibleremotemountsareshowninAppendixE.The
waveguideflangesareavailableformountingallstandardwaveguidesizes.
CombinersforAntennaSharing
TheGigaPlusODUisdesignedwithaneasyslipfitinterfacetotheantenna.Ifdesired,
twounitsmaybeconnectedtothesameantennafor1+1hotstandbyapplicationorto
aggregatetwochannelstogetherformorecapacity.Trangocanprovidemultiple
combineroptionsbasedonthecustomerapplicationsasthetableshowsbelow:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
24
Table2CombinerCrossReference
AppendixEgivesdetailedinformationonwhichspecificfrequencybandsaresupported
foreachtypeofcombiner.
PowerSupply
Trangocanprovidepowersuppliesforrackmountapplications.ThePSUPPLY1U48isa
rackmountpowersupplywith6.5Amperecapacitythatcansupportmultiplecolocated
GigaPlusunits.Thepowersupplymustbekeptinatemperaturecontrolled
environmentwithintheoperatingtempof0to40degC.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
25
KeyFeatures
FlexibleInterfacesandFormFactor
TheGigaPlusisanativeEthernetANDnativeT1/E1radio.Capacitycanbesplitto
supporttheEthernetandT1/E1circuits,ordedicatedtoonlytheEthernet.Thereare2
trafficportsonthefrontpanelthatsupport10/100/1000BaseT,and2thatcansupport
1000BaseTor1000BaseLXSingleorMultimodefiber.
Theformfactorissmallenoughtosupporttwounitsina1Urackspace,andwith
supportforupto1000feetofcabletotheODU,allowsmoreoptionsfortowercable
location.
TrafficCapacity
WithQAM256modulationina56MHzchannel,thelinkcansupportcapacitiesupto
375Mbpsfullduplexor750Mbpsaggregate,with8T1/E1circuitsprovidedforTDM
applications.
Thebasemodelcomeswith100MbpsEthernetfullduplexcapacityandtherearetwo
upgradekeysavailablethatcanopentheentire375Mbpscapacity:
GigaPlusKey1
Description:Unlocksthroughputcapacityfrom100upto200MbpsFullDuplexpayload
(200Mbpseachdirection)Coversonelink(2licensekeysprovided)
GigaPlusKey2:
Description:Unlocksthroughputcapacityfrom100MbpsuptoMaximumcapacityFull
Duplexpayload(375Mbpseachdirection)Coversonelink(2licensekeysprovided)
GigaPlusKeyPDH:
Description:Unlocksthe8T1/E1circuitsonthefrontpanel.100MbpsuptoMaximum
capacityFullDuplexpayload(375Mbpseachdirection)Coversonelink(2license
keysprovided)
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
26
IndustryLeadingSystemGain
ThecombinationoftheHighTransmitpowerandsuperbreceivesensitivityoftheODU
provideforoneofthehighestsystemgainsavailableonthemarkettoday.
ThetechnologybehindthehighsystemgainrelatestotheLowDensityParityCheck
(LDPC)forwarderrorcorrection(FEC)codingthatwasimplementedintheGigaPlus
design.
TheFigurebelowshowshowtheLowDensityParityCheck(LDPC)coding,which
replacestheolderReedSolomonlockcoding,reducesthesignaltonoiseratiorequired
toachievea1E6BitErrorRate(BER).Asaresult,thereceivesensitivityisloweredby
thesameamount,typically3to4dB.
Figure8LDPCvs.ReedSolomon
Systemgainisoneofthemostimportantmetricsforamicrowavesystembecauseithas
adirectrelationshiptothelinkreliability,antennasize,andtransmissiondistanceas
showninthefigurebelow.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
27
FullLicensedbandfrequencyandT/Rspacingsupport
AllstandardfrequencybandsandT/Rspacingsareavailableforthisproductwithno
productrolloutdelays.TheFigurebelowshowsthecurrentlysupportedbandandT/R
spacingsforHPandHP2ODUswhichareusedwiththeGigaPlus.Thenumbers
representthenumberofsubbandsforeachfrequencyband.
Table3GigaPlusBandandT/RSpacingOptions
SpecificinformationonthesubbandsisshowninAppendixE.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
28
ForHPODUmodelstheTRspacingcanbecustomizedviaasoftwarecommandaslong
asthenewTRspacingandchannelbandwidthsarewithinthediplexerrange.
SeeAppendixAformoreinformation
ChannelSizesfrom3.5MHzto80MHz
Acrossallthefrequencybands,thesystemcansupportchannelsizesaslowas3.5MHz.
ThetablebelowshowsthevariouschannelssupportedandtheEthernetcapacitiesfor
eachinnonACMmode.ACMcapacitieswillbeslightlylessduetotheACMoverhead.
AdaptiveCodingandModulation
Adaptivecodingandmodulationprovideserrorfreehitlesschangingofthemodulation
levelforafixedchannelwidthtoallowthelinktobemaintainedduringheavyweather
relatedfadingconditions.Insteadofthelinkdroppingandnotrafficpassing,thelink
willbemaintainedwithalowercapacityuntilthefadingconditionisremoved,atwhich
timethelinkwillreturntothenormalmodulationlevel.
Thetransitionsbetweenmodulationlevelsarecontrolledbythresholdswhichareuser
modifiableandeachtransitionismadewithoutdroppingpacketssincebothendsofthe
linkcoordinatethetransitionautomatically.
TheFigurebelowshowstheAdaptiveCodingandmodulationinaction.
Figure9AdaptiveCodingandModulation(ACM)
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
29
LinkProtectionthrough1+1HotStandby
TwoGigaPlusODUscanbemountedusingacombinerdirectlyonasingleantenna,and
withanoptionalshortjumpercablebetweenthetwoIDUs,provide1+1hotstandby
functionalitytoprotectagainstahardwarefailureofoneGigaPlusIDU,ODUorIFcable.
Thehotstandbyfeatureisavailableonallfrequenciesandcansupportlayer2andlayer
3routednetworkstoallowimmediateroutingofthesignaltothestandbylink.The
failovertimeistypicallylessthan200milliseconds.
1+1isavailableusingequalandunequalpowerdivisioncombinerswiththesame
polarizationforbothODUs.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
30
2.0 WirelessOperationDetail
ChannelBandwidth
Thesystemsupportsthefollowingchannelbandwidths:
3.5MHz
7MHz
10MHz
13.75/14MHz
20MHz
27.5/28MHz
30MHz
40MHz
50MHz
55/56MHz
80MHz
Thespeedischangedviathemanagementinterfaceusingthespeedcommandora
dropdownboxinthewebinterface.Bothsidesofthelinkmustbechanged
independentlytoensuretheRFlinkisestablished.
Modulation
Thefollowingmodulationlevelsaresupportedwithineachofthechannelbandwidths
shownabove:
QAM256
QAM128
QAM64
QAM32
QAM16
QPSK
Themodulationischangedviathemanagementinterfaceusingthespeedcommandor
adropdownboxinthewebinterface.Bothsidesofthelinkmustbechanged
independentlytoensuretheRFlinkisestablished.
MeanSquaredError(MSE)
MeanSquareError(MSE)issimilartoSignaltoNoiseRatio(SNR)exceptthatitaccounts
fordistortionandinterferenceinadditiontonoisepower.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
31
DistortionmaycomefromseveralsourcessuchasbadEthernetcables(poorshield,
damaged,orlowquality),pathdegradationssuchasmultipath,orFresnelzone
encroachment.
Interferencecancomefromothertransmittersonthetower,aswellasfromsources
insideanindoorshelter.Highpowertransmittersinsideasheltercancauseinterference
whennearthePoEdeviceorwhenlocatedveryclosetothecabling.
TherearemaximumacceptableMSEvaluesforeachmodulationwhichareusefulin
determiningthequalityofthelink.TheMSEvaluereportedisonlyrelevanttoonetxrx
path,sotheMSEofeachtxrxpathmustbeevaluatedtoverifythelinkisoperatingas
expected.Thelowerthenumberthebetter,soa35dBisbetterthana30dB.Thetable
belowshowsthemaximumMSEvaluetoexpectinIFLoopback,NormalOperation,and
AbsoluteMaximum.
MSEExpectedandMaximumValues(dB)
MaximumExpectedvalue
IFloopback
QAM256
QAM128
QAM64
QAM32
QAM16
QPSK
36
36
36
36
36
36
MaximumExpectedvalue
Normaloperationatmax
power
34
33
32
30
30
29
AbsoluteMaximumfor1E
6BERSensitivityThreshold
28
25
22
19
16
Table4MSEExpectedandMaximumValues
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
32
AdaptiveCodingandModulation(ACM)
TheACMfeatureworksinconjunctionwiththeMeanSquareError(MSE)values.Using
theacmcommand,theoperatorenablestheACMfunctionandthensetsthespeed
usingthespeedcommand.WhenACMisenabled(on)andthelinkMSEbecomes
degraded,theradiowillautomaticallyshiftdowninmodulationandspeedbasedonthe
MSEdegradethresholdsettingshowninTable5.Sincetheoriginalsetmodulationmay
beQAM256,QAM128,QAM64,QAM32,orQAM16,thetableshowseachsettingand
totalrangeofmodulationlevelsthatwillbeusedforthatsetting.Thethresholdvalues
canbechangedbytheoperatorifdesired,howeverthedefaultvaluesshownarethe
recommendedsettings.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
33
SpeedSettingQAM256
Modulation
Improve
Degrade
QAM256
NA
27.2
QAM64
29.2
24.3
QAM16
25.3
18.5
QPSK
20.3
NA
SpeedSettingusingQAM128
Modulation
Improve
Degrade
QAM128
QAM64
QAM32
QAM16
QPSK
NA
27.2
29.2
24.3
26.3
21.3
25.3
18.5
20.3
NA
SpeedSettingusingQAM64
Modulation
Improve
Degrade
QAM64
QAM32
QAM16
QPSK
NA
24.3
26.3
21.3
25.3
18.5
20.3
NA
SpeedSettingusingQAM32
Modulation
Improve
Degrade
QAM32
QAM16
QPSK
NA
21.3
25.3
18.5
20.3
NA
SpeedSettingusingQAM16
Modulation
Improve
Degrade
QAM16
NA
18.5
QPSK
20.3
NA
Table5ACMThresholdTable
!
TheACMfeaturewillautomaticallyshiftthemodulationlevelupordownbasedonthe
MSEvalueandtheabovespecifiedthresholds.Ifyoudonotwanttheradioto
automaticallychangespeedsettingsthendisableACM.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
34
ACMDetailedDescription
Ifthechannelconditionsdegradeduetomultipathorfading,theMSEmaybeaffected.
Thistypicallyoccursduringheavyrainandismorepronouncedwithhigherfrequencies
andlongertransmissionpaths.
Ifthedegradethresholdshowninthetableisexceeded,theACMenginewillcoordinate
ashiftofthemodulationleveldowntothenextlevelshown.Nopacketswillbe
droppedduringthistransitionsincethetwoendsofthelinkarecoordinatingwitheach
othertoensurethattheswitchoccursatthesametime.Sincelowermodulationlevels
aremorerobustagainstchannelfadingandmultipath,theycantolerateahigherMSEas
isevidentfromthetable.
Ifthelinkconditionscontinuetodegrade,theshiftsdownwardwillcontinueuntilthe
lowestmodulationlevel,QPSK,hasbeenreached.Iffurtherdegradationoccursabove
themaximumMSE(shownpreviouslyinTable5)forQPSK,thelinkwillbedroppedand
packetlosswilloccur.IfthelinkMSEstartstoimprove,however,theACMenginewill
graduallyshiftthemodulationlevelupastheimprovethresholdsarepassed.
WhenACMisactivethemodulationlevelmaybeasymmetrical,meaningthatone
directionmayberunningatQPSKandtheothermayberunningattheoriginallyset
highermodulationsuchas256QAM.ThisisbecausetheACMengineacts
independentlyateachendpointofthelink.AlowlevelBinaryPhaseShiftKeying(BPSK)
channelismaintainedoutofthedatapathbetweenthetwoendsofthelinktoallow
verytightcoordinationoftheswitchesinmodulation.Onlydatatrafficcapacityinthe
directiontowardstheaffectedreceiverwillbereduced,maintainingperformanceon
theunaffecteddirection.
DuringallACMoperationthetransmitterpowerremainsatthesetlevelifATPCisoff.If
enabled,ATPCactsnormallywhenACMisactiveandmayincreaseordecreasethe
transmitpowerbasedonRSSIlevels.
TheacmcommandprovidesconfigurationoftheACMandmustbedoneonbothsides
ofthelink.ThelinktestcommandfromtheCLIcanbeusedtoviewthecurrentTXand
RXmodulationlevels.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
35
WirelessLinkCapacity
ThetablebelowshowsthecapacityofthesystemforeachnonACMspeedsetting.The
capacitiesfortheACMsettingswillbeapproximately12%lowerduetotheadditional
overheadoftheACM.
AllcapacitiesshownareinMbpsfullduplex,meaningthattheaggregatebidirectional
capacityistwicethenumbershown.
Thecapacitiesshownarealsolayer2using1518bytepacketsforIPV4.Layer1numbers
willbehigher,especiallyforsmallpackets:
BW(Mhz)
Symbol
Rate QPSK
(Msps)
4
7
10
14
20
28/30
40
50
55/56/80
3
5.6
8.32
12.2
17.42
26
34.83
43
49.5
4
9
14
21
31
47
63
78
90
9
19
29
44
63
95
128
157
181
12
24
36
54
78
118
158
195
225
15
30
45
66
96
142
192
238
275
18
35
52
78
111
166
225
277
320
20
39
59
88
126
190
256
318
365*
*375Mbpswhensettospeed80qam256
Table6MaxLinkCapacity(Mbps)fornonACMSpeedSettings
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
36
AutomaticTransmitPowerControl(ATPC)
ATPCandtargetRSSIworktogethertocontroltheremotesidepoweroutputinorderto
achieveoptimalsignalstrength.ATPCcanbeenabledordisabled.Whenenabled,
ATPCwilladjustthepoweroftheremotesidebasedonthelocaltargetRSSIsetting.
IfthecurrentRSSIvalueislowerthanthetargetRSSIsettingofthelocalradio,thelocal
radiowillsendcommandsovertheairinstructingtheremoteradiounittoincreaseits
outputpowertoachievethetargetRSSIsettingwithin+/2dB.
IftheRSSIvalueishigherthatthetargetRSSIsetting,theremoteradiowillbe
commandedtoreducethepoweruntileitherthetargetlevelisreachedwithin+/2dB
ortheTXpowerhashittheminimumlevel(SeeTable8).
ATPChasStepSizeandMaxPowersettingstolimittheoutputpoweroftheunitand
preventaviolationofthelicense.
ThepowersettingcannotbechangedonceATPCisenabled.Tomanuallychangethe
powersetting,ATPCneedstobedisabled.
ATPCMaxPower&StepSize
SettingsforATPCMaxPowerandtheATPCStepSizecontrolhowtheATPCfunctionwill
behavewhenattemptingtoachievetheTargetRSSI.ATPCMaxPoweristhemaximum
powersettingATPCcansetthepoweroutputtowhentryingtoreachtheTargetRSSI.
ATPCStepSizeistheamountofdBperattemptthatATPCcanchangepoweroutput.
TransmitterMaximumPowerOutput
MaximumTransmitterpoweroutputisdependentonthebandofoperationandthe
modulationlevel.BoththeHP1andHP2ODUmodelshavethesamemaximumpower
levelsforeachbandandmodulation.
Thereisnodependencyonthechannelbandwidthusedwithinaparticularband.Asan
example,thepowerlevelforQAM256withinthe6GHzbandisthesamefor3.5MHz
channelsasitisfor56MHzchannels.Thetableillustratesthisandshowsthemaximum
setpowerlevelsforeachmodelfamily,band,andmodulationlevel.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
37
TransmitterMaximum PowerOutputLevel (dBm)
Modulation
Level
6
GHz
7
GHz
8
GHz
10 11 13
15
18
GHz GHz GHz GHz GHz
23
GHz
26
GHz
28
GHz
32
GHz
38
GHz
256QAM
+24
+24
+24
+21
+19
+19
+16
+16
+16
128QAM
+20
+20 +17
+17
+17
64QAM
+25
+25
+25
+22
+22
+21
+21
+20
+20
+20
+17
+17
+17
32QAM
+28
+28
+28
+26
+26
+23
+23
+22
+22
+22
+21
+21
+21
16QAM
+28
+28
+28
+26
+26
+23
+23
+22
+22
+22
+21
+21
+21
QPSK
+30
+28
+26
+26
+25
+25
+25
+23
+23
+23
+21
+20
+20
+19
Table7MaximumSetPowerLevelsbyBandandModulation
WhenATPCisactive,theatpc_maxpowermustbesettothemaximumpowerforthe
highestmodulationused.
TransmitterMinimumPoweroutput
TheminimumtransmitpowerthatcansetislimitedbytheODUmodelandisnot
dependentonthemodulationlevellikethemaximumlevelsare.Thetablebelowshows
theminimumpowerlevelsforeachbandandmodelfamily.Thelevelsarealsothe
minimumlevelsthatATPCcansettheoutputtowhenenabled.
TransmitterMinimumPowerOutputLevel(dBm)
HPODUModel
6
GHz
7
GHz
HPXXYYYYZZ
+9
+9
+9
NA
+6
+3
+3
HP2XXYYYYZZ
+0
+0
+0
+0
+0
+0
+0
8
10
11 13 15
18
GHz GHz GHz GHz GHz GHz
23
GHz
26
GHz
28
GHz
32
GHz
38
GHz
+2
+2
+2
+2
+1
+1
+0
+0
+0
+0
+0
+0
Table8MinimumTXsetpowerbyband
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
38
ReceiverMaximumInput
ThemaximumreceiverRFlevel,measuredbyRSSI,isdepictedinTable9below.Ifthe
RSSIvalueishigherthanlistedforthemodulationbeingused,packetlossmayresult.
Whenoperatingshortrangelinkswithahighreceiverinputlevel,alwaysmakesurethat
thetransmitterpowerisadjusteddownfromthemaximumtoensurethelevelsshown
belowarenotexceeded,oractiveATPCwithatargetrssithatisatleastseveraldB
belowthelevelsshowntoprovideasafetymargin.
ModulationLevel
MaxRSSI
256QAM
24dBm
128QAM
22dBm
64QAM
20dBm
32QAM
18dBm
16QAM
16dBm
QPSK
14dBm
Table9MaxReceiveLevelInput
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
39
3.0 NetworkOperationDetail
Thissectiondescribeskeynetworkrelatedelementsofthesystemindetail.
1+0NonProtectedLinkConfiguration
ThediagrambelowshowsthetypicalsetupoftheGigaPlusinanetworkenvironment.
Althoughthisconfigurationiscallnonprotected,itiscommonlyusedinring
architectureswhichuselayer2or3routingtoreroutethetraffictheotherdirectionif
thelinkfails.
TheFigurebelowshowsthenonprotected1+0linksetupwithswitchesorrouters.
Figure101+0Setup
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
40
1+1HotStandbyProtectedLinkConfiguration
Figure11showstheprotected1+1hotstandbyconfiguration.
ThisconfigurationconsistsoftwoGigaPlusunitsateachendofthelink.Theeasiestway
tothinkofa1+1setupisasingle1+0linkoperatingnormallywithanotherstandbylink
readytotakeoverintheeventofafailurecondition.
Thestandbyunitsmonitortheactivelink,includingreceivingthesamesignalfromthe
farend,butthestandbydoesnottransmitasignalunlessitbecomestheactiveunitas
theresultofafailuredetectionandsubsequentfailoverevent.Thestandbyunits
monitorthehealthoftheactiveunitbypollingitthroughtheredundancycablepart
numberCBLDATRIU3.
Ifthereisaneventthattriggersafailoverfromactivetostandby,bothendsofthelink
willswitchtothestandbylink.Thismeansthatanetworkswitchorroutercapableof
RapidSpanningTreeProtocol(RSTP),BGPorOSPFroutingmustmovethetraffictothe
standbylinkonbothends.Toassistinthisprocess,RapidPortShutdown(RPS)canbe
enabledonthefailedunitasanactionafterafailoveroccurs.
Figure111+1Setup
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
41
TheTablebelowshowstheeventswillcauseafailoverfromactivetostandby:
Event
FailoverType
(localSite)
FailoverType
(remotepair)
ModemlinklostonActive
Hardware
Hardware
CLIutype_switch
Software
Hardware
PowersupplyfailureonActive
Software
Hardware
RebootonActive
Software
Hardware
ODUPLLfailureonActive
Software
Hardware
Violationofthresholdsetting
Software
Hardware
Linkrelatedcommand(seelist)
Nofailover
Hardware
PowersupplyfailureonStandby
Nofailover
Nofailover
RebootonStandby
Nofailover
Nofailover
Odupoweron/offonStandby
Nofailover
Nofailover
ODUPLLfailureonStandby
Nofailover
Nofailover
ModemlinklostonStandby
Nofailover
Nofailover
1+1cableremoval/failure
Nofailover
Nofailover
ACMTx/Rxprofilechanges
Nofailover
Nofailover
Table10FailoverEvents
Hardwaretriggeredfailover
IntheeventthatthemodemRXlinkislost(statuschangesfrom1to0),ahardware
triggeredfailoverwilloccurandthefollowingsequenceofactionswilloccur:
Actions:
1) TheIFtransmitsignalwillbeshutoffontheactiveunitandenabledon
thebackupunit
2) ThestandbyGigaPlusutypewillchangefromstandbytoactiveandthe
previouslyactiveunitutypewillchangetostandby.
3) TheEthernetportwillbeshutdownonthenewstandbyunitifRPSwas
enabled.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
42
4) Thefarendofthelinkwillalsofailoversincethetransmitterswitchwill
causethefarendtoloselockaswell.Steps13abovewillrepeatforthe
farend.
Hardwareinitiatedfailovertothebackuppairwilloccuronthefarendunitduetothe
smallgapinthetransmitterbeingswitchedfromactivetostandbyonthelocalside.The
totaltimeforthefailovertooccuristypically150200milliseconds.
Ahardwarefailoverwillonlyoccurthefollowinginitialconditionsaremet,otherwise
noneoftheeventsintheTablewillcauseafailover.
1)
2)
3)
4)
AStandbyunitisdetected
TheactiveRadiohasitsRXlocked.
Theelectiontimeperiodisover.
Theguardtimehaselapsed
Softwaretriggeredfailover
SoftwaretriggeredfailoverisInitiatedbythesoftwarebasedonthefollowing
conditions.Softwarefailoverswilltake35secondsduetothefactthattheeventsare
polledbytheoperatingsoftwareinsidetheunit.
1) ODUPLLunlocked
2) Violationofathresholdsettingwhenfailoverisconfiguredasoneofthe
thresholdactions.
3) PowerSupplyfailure
Usertriggered(manual)failover
InitiatedbyuserissueCLI/SNMP/webcommandsasshownbelow.Typicallytheonly
usertriggeredcommandthatshouldbeexecutedistheutype_switchcommand,which
isusedwhentheoriginalactiveunitisrestoredorreplacedandtheoperatorwantsto
returnittoactivestatus.Theothercommandsarelistedtomaketheoperatoraware
thattheywillcauseanunintentional(andusuallyundesired)failover.
Commandsthatwillforceafailover
1. Usingtheutype_switchcommandtorestoretheactiveafterafailover
a. ThiscommandcanonlybeinitiatedontheActiveunit.
b. AlowlevelcommandissentfromActivetoStandbyunittoturn
ontransmitter.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
43
2. Usercommands:Whentheoperatorchangesthefollowingsettingsonthe
activeunit,anunintentionalfailovermayoccur.Itisnotrecommendedtorun
anyofthesecommandswhileanactive1+1linkisrunning:
a. acmenable
b. bootimageupgradeodu
c. datapath
d. datapattern
e. loopback
f. opmode
g. odupower
h. power
i. reboot
j. speed
RapidPortShutdown(RPS)
GigaPlussupportstheshutdownoftheEthernetportstoassistinreroutingtrafficinthe
eventofalinkfailure.Whenenabledatbothendsofthelink,AllEthernetportsatboth
endsoftheactivelinkwillbeshutdownwithin50mSofthemodemlockstatus
changingfrom1to0ateitherendofthelink.
RPSemulatesacablefailureiftheentirelinkisthoughtofasacable,andwilltriggera
routingchangewhenusedwithaswitchorroutersetupforRapidSpanningTree
Protocol(RSTP)oranotherlayer2routingprotocolatbothends,asisnormalinaring
architecture.Forhigherlayerroutingprotocolstheportsarenormallyleftactiveinthe
eventofalinkloss.
ItishighlyrecommendedthattheoperatorenableACMwhenusingRPSsincethefade
marginwillbemuchhigherthananonACMspeedsetting,preventinglinklossand
subsequentreroutingduringweatherrelatedevents.
VLANTagging
GigaPlussupportstaggedpacketswithVLANIDsrangingfrom04089.Thelastseven
VLANIDsareusedinternallyasdescribedinthePortMappingSectionbelow.IfInBand
Management(IBM)isused,themanagementtrafficcanbeconfiguredtohaveaVLAN
tagtoallowtheswitchinternaltothesystemtoidentifypacketsinthedatastreamand
directthemtotheCPUforprocessing.TheVLANIDformanagementisuserspecified
usingtheibmcommand,withafactorydefaultVLANIDof4085.Itisrecommendedthat
themanagementtrafficbetaggedwiththehighestprioritysettingtoensurethatinthe
eventofnetworktrafficsaturation,themanagementtrafficwillhaveprecedence(See
ClassofServiceSection).UntaggedIBMisalsosupportedinFirmwarerelease2.0and
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
44
higher,butthereisnoguaranteeofprioritizationwhenthetrafficisonthesameport
andtheusertraffic.
QinQSupport:GigaPlussupportsQinQ,however,duetotheportmappingfeature
beingenabledbydefault,theoperatormustdisabletheportmapping.SeethePort
Mappinganddiscussiononsmart_modebelowformoreinformation
PortMapping(802.1q)
Theportmappingfeatureisafixedsettingandprovidesanadditionalamountofdata
securitysincetrafficontheindividualEthernetportsissegmentedandisolatedfrom
trafficonotherEthernetports.PortmappingisimplementedbyusingfixedVLANtags
internaltotheGigaPluslink.WhenEthernettrafficarrivesinaport,itmaybetaggedor
untagged.BothtaggedanduntaggedpacketsaretaggedwithanadditionalVLANTag
dependingonwhichporttheyarrivedatasfollows:
GE1:GigE10/100/1000BaseTport:VLANID4091
GE2:GigE10/100/1000BaseTport:VLANID4092
GE3:GigESFPport:VLANID4093
GE4:GigESFPport:VLANID4094
Attheotherendofthelink,theinternaltagsareremovedandtheoriginalpacketsare
sentoutunaltered.EssentiallytheGigaPlusisperformingdoubletaggingonpackets
thathavealreadybeentagged.
Portmappingisactivewhensmart_modeison.
QinQ/DoubleTaggingandsmart_mode
Iftheoperatorwishestosendpacketsthatarealreadydoubletaggedthroughthelink,
thensmartmodemustbedisabled.Withsmart_modeoff,alltrafficcominginonGE1
willappearatBOTHGE1andGE2portsonthefarend.Smart_modemustbeenabled
onbothendsofthelinkanditisrecommendedthatonlyoneofthetrafficportsGE1or
GE2beutilizedateachend.Oneaddedbenefitofsmart_modebeingoffisthatthelink
canactasamediaconverter.SideAofthelinkcanbecopperRJ45andsideBcanbe
GigEfibersingleormultimode.Themediaconversionwillonlyworkfor1000BaseT,as
thefiberinterfacedoesnotsupport10/100BaseTmodes.Itisrecommendedthatboth
portsbesettothesamespeedandduplexatbothendsofthelink.
InBandManagement(IBM)withVLANtaggingwillnotoperatewiththesmartmode
turnedoff.OutofbandmanagementandIBMwithVLANtaggingoff(SWV2.0)willstill
beavailableaswhenSmartModeisoff.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
45
ClassofService(802.1p)
GigaPlushasClassofServicecapabilitiesthatprovidepriorityfordifferenttypesof
trafficacrossthelink,whentheCOSbitsintheVLANtagonincomingEthernettraffic
areset.
Thetrafficcanbeclassifiedinto8priorities(07basedontheVLANtagCOSbits).Thisis
doneexternaltotheGigaPlusunitusingaswitchorapplicationtosettheprioritytag
field.OncethetaggedtrafficwithCOSprioritybitssetarrivesintheGigaPlusEthernet
port,theinternalswitchwillperformprioritizationonthetrafficbymappingittooneof
8queues.
The8queuesareFIFOsthatareemptiedintoasingledatapipegoingintothemodem
andsubsequentlyovertheair.Theschedulingofthequeuetrafficintothemodemdata
pipeisstrictpriorityfollowingthefollowingrule:
COSQ7>COSQ6>COSQ5>COSQ4>COSQ3>COSQ2>COSQ1>COSQ0
ThisruleessentiallymeansthatthesystemwillemptyCOSQ7beforesendingany
COSQ6packetsacrossthelink,andifbothCOSQ7andCOSQ6areemptythenCOSQ5
packetswillbesent,etc.
Thedefaultprioritymappingofthepacketwillbesetasfollows:
COSpriority0COSQ0,LowestPriorityQueue
COSpriority1COSQ1
COSpriority2COSQ2
COSpriority3COSQ3
COSpriority4COSQ4
COSpriority5COSQ5
COSpriority6COSQ6
COSpriority7COSQ7,HighestPriorityQueue
Thesedefaultmappingscanbechangedwiththecoscommand,allowingthepacketsto
bemappedintoanyoneofthe8queuesbasedontheCOSbitintheVLANtag.
PortPriority
TheportpriorityfeatureallowsforuntaggedtrafficarrivingintoeachEthernetportto
haveprioritylevelassignedtoit.Ifthearrivingtrafficisalreadytaggedthenthattag
prioritylevelwillbehonoredovertheportpriority.Theportprioritysettingwill
determinewhichporttrafficisforwardedintheeventofmoretrafficcomingintoallthe
portsthanthecapacityofthesystemcanhandle.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
46
Portprioritycanaugmentportratelimiting,especiallyinwhenACMisactiveandthe
linkhasdownshiftedtoalowermodulation.Theportcommandisusedtosettheport
priorityforeachport.
PortRateLimiting(Ingress)
Theportratelimitingfeatureisusedtorestricttheingresstrafficrateonaspecific
Ethernetport.ThisisusefulforServiceLevelAgreements(SLAs)whenbothportsofthe
GigaPlusarebeingusedtosupplytwocustomersandthechannelcapacityislimitedto
lessthanthesumofthecapacityofthetwoEthernetports.
Forexample,ifbothportsaresetto1000BaseT,andtheRFchannelcapacityis375
Mbps,settingGE1toratelimitof125MbpsandGE2toaratelimitof250Mbpswill
alwaysguaranteethatbothusershavethebandwidthofthechannelreservedforthem.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
47
4.0 LinkManagement
Thissectiondescribesthevariouswaystomanageandmonitorthehealthand
performanceoftheGigaPlusmicrowavebackhaullink.
Overview
TheGigaPluscanbemanagedthroughthefollowingmethods:
GraphicalUserInterface(GUI):
WebBrowser:Remoteaccessviainbandandoutofbandmethodswith
view/configurationlevelaccess(singleuser+password)usinganystandardweb
browsersuchasInternetExplorer,Chrome,Firefox,andSafari.
CommandLineInterfaces
SSHEncryptedremoteaccessviainbandandoutofbandmethodswith
separateviewandconfigurationlevelaccess(passwordprotected)
TelnetRemoteaccessviainbandandoutofbandmethodswithseparateview
andconfigurationlevelaccess(passwordprotected)
ConsoleLocalAccessusingaserialcableforbenchconfigurationwithseparate
viewandconfigurationlevelaccess(passwordprotected).
SNMPRemotecontrolandmonitoringviainbandandoutofbandmethods
usinganythirdpartyNetworkManagementSoftware(NMS).SeeAppendixDfor
detailsontheMIBandSNMPobjects.StandardMIBIISystemLeveland
EnterpriseMIBBlocksaresupportedwithmonitoringforallmajorlinkhealth
andtrafficrelatedmetrics.
DefaultIPAddress
ThefactoryconfigurationforIPaddressis192.168.100.100forallunits,andtheIBM
defaultaddressis172.16.1.1fortheAsideunitand172.16.1.2fortheBsideunit.
DefaultPasswords
Thedefaultpasswordsareshowninthetablebelow:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
48
Accessmode
Username
Password
CLIViewMode
admin
trango
CLIConfigMode
N/A
trango
CLIDebugMode
N/A
N/A
WebInterface
admin
trango
SNMPReadCommunity
N/A
public
SNMPWriteCommunity
N/A
private
SNMPTrap
N/A
trapstr
Table11DefaultLoginPasswords
GraphicalUserInterface(WebBrowser)
ToaccessthebrowserinterfacesimplyopenyourWebbrowserandentertheIPaddress
oftheradio.Aloginwindowwillpopup,requiringausernameandpassword(Figure
10).EnterthedefaultormodifiedusernameandpasswordthenpressOK.EitherHTTP
orHTTPSmaybeused.
Figure12WebBrowserLogin
ThefirstpagetodisplaywillbetheSystemInfoPageasshownintheImagebelow:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
49
Figure13SystemInfoPage
ThemainformatoftheGigaPlusWebInterfaceisshowninFigure11above.Thelayout
isdesignedtoallowtheoperatortoviewthecurrentlinkstatusonallpages.Theleft
sideofthedisplayshowsvariousfoldersorganizedbyfunction.Eachfoldercanbe
openedandexploredforthevarioussubpagesbysimplyclickingonthefolders
themselves:
NavigationBar:Thenavigationbartheleftshadedareacontainingthefunctional
folders.Thenavigationbarcontainslinktothefollowingfolders:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
50
RadioSettings:TheessentialRadioLinksetupparameters,TX/RXfrequency,
transmitterpower,speedandmodulation,aswellasthecapacitylicenseare
foundhere.Settingsfor1+1failoverarefoundhere.
NetworkSettings:TheessentialNetworksetupparameters,suchasIPaddress,
IBMsetup,andSNMPsetuparelocatedhere.
SystemStatus:Showsmostofthebasicconfigurationparametersoftheradio,
includingmodelsandserialnumbers,alongwiththecurrentlinkstatusincluding
PLLlocks.
SystemStatistics:CounterinformationonallinterfacesRF,Fiber,andGigEis
displayed.Thesestatisticsarerefreshedautomatically.
Diagnostics:Thisfoldercontainspagesthatshowcurrentsystemsettings,the
systemlogwhichrecordsalltheeventsandusersettings,andaspecial
diagnosticexportfunctionthatproducesatextfileforTrangoTechSupportto
usewhentroubleshootingisrequired.Thisfolderalsohasapagetocontrolthe
loopbackfunctionandantennaalignmentmodewhichincreasestheupdaterate
fortheantennaRSSIvalues
UserSetting:Usercanchangetheconfigpasswordandenterthelicense
upgradekeyforhighercapacity.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
51
CommandLineInterface(CLI)usingSSH,TelnetorConsole
Alltypicalradiofunctionscanbemanagedviathebrowserinterface,buttheCommand
LineInterface(CLI)hasadditionalfunctionalitythatfacilitatesinstallationand
troubleshooting.
TheCommandLineInterfacehas3nodes:View,Config,andDebug.Loggingintothe
radioviaCommandLineInterfaceiscoveredherebriefly,andacompletelistingofall
CLIcommandsisprovidedinAppendixA
LoggingintotheradioviaCommandLineInterfaceiscoveredherebriefly.Acomplete
listingofallCLIcommandsisprovidedinAppendixACommandLineInterface.
LaunchTelnet
Openacommandprompt(DOS)sessiononyourPC(WindowsStarticonandselect
Run).OpenaTelnetsessionbytyping:
telnet [ip address of radio]
Example:
C:>telnet 192.168.100.100
OnceattheCLIloginprompt,typeintheloginandpressenter,thenthepasswordand
pressenter.
CLI login: admin
Password: (No characters will be display during input)
Trango System:
v1.0.0
(CLI-view)#
Iftheincorrectpasswordisenteredduringlogin,thesystemwillallowtwomoretries
beforeterminatingatelnetsession.Anewsessionwillneedtobeopentotryagain.
ToterminateaCLIsession(TelnetorConsole)simplyclosetheconsolewindow.ACLI
SESSIONCANALSOBETERMINATEDFROMTHEDEBUGNODEWITHEXITCOMMAND.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
52
ALLCONFIGURATIONCHANGESHAVETOBESAVEDTOFLASHINORDERTOBE
PERSISTENTACROSSAREBOOT.ASINGLECONFIGSAVECOMMANDWILL
SAVEALLCONFIGURATIONCHANGES
Example:
CLI login: admin
Password:
Trango System:
v1.3.0
(CLI-view)# config
Password:
(CLI-config)#
(CLI-config)#exit
SUCCESS
(CLI-view)#
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
53
TheCommandLineInterfaceskeepsahistoryofcommandsused,pressingtheuparrow
willdisplaypreviouscommandsused.TheCLIcansupportsautocompleteofa
commandbeingtypedbypressing<tab>key.Ifacommandispartiallytypedfollowed
immediatelybya?itwilldisplayallrelatedcommands.
Example:
(CLI-config)#
targetrssi
tdm
telnetd
temp
tftpd
threshold
trap
(CLI-config)#
TYPE?FORALISTINGOFALLCLICOMMANDS.
ChangingPassword
Thedebugandviewnodesharethesamepassword.Theconfignodehasaseparate
password.Theviewanddebugmodepasswordischangedinthedebugmode.The
confignodepasswordischangedintheconfignode.UsetheCLIcommandpasswrdto
changethepassword.Theexamplebelowdemonstrateschangingthepasswordforthe
confignodetocontrol
Syntax: passwrd <newpassword> <newpassword>
Example:
(CLI-config)# passwrd control control (The password must be entered twice)
Ifthecommandisproperlyexecuted,thesystemwillreturnaSUCCESSandreturnto
theCLIconfigprompt.
Ifthepasswordislostandtheunitislocked,thepushbuttonontheaccesspanelcanbe
usedtoresetthepasswordanddefaultIPbacktothefactorysettings
ConsolePort
GigaPlusfeaturesaconsoleportwhichismultiplexedwiththeportforthe1+1hot
standbyoperation.If1+1hotstandbyisactivetheconsolecablecannotbeused.The
consoleportisusefulintheeventthattheunitcannotbeaccessedviaTCP/IP(HTTPor
Telnet).ATerminalEmulationprogramsuchasHyperTerminalorPuttycanbeusedto
accesstheradiosCLIviatheconsoleportasshowninFigure12.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
54
Figure14ConsolePortSetting
SimpleNetworkManagementProtocol(SNMP)
TrangoLINKGigaPlussupportsSimpleNetworkManagementProtocol(SNMP)for
networkmanagement.Networkmanagementconsistsof4categories:
1. Configuration
2. Accounting
3. Alarm
4. Monitoring/Control
Thesecapabilitiesallowthenetworkoperatortoprovidesuperiorservicesthrough
highernetworkaccessibilityandintegratedaccountingsystem.UseofSNMPrequires
thecustomertohavealreadyimplementedaNMSorSNMPsoftwarepackage.
TheTrangoSNMPsolutionsupportsMIBII(systemonly)andtheTrangoproprietary
ManagementInformationBase(MIB).
UsersinterestedinusingtheSNMPfunctionalityshouldreviewtheentireTrangoLINK
GigaPlusMIB,foundinAppendixD,foracompleteunderstandingofitsfeatures.
ThefollowingisanoverviewofsomeofthemorecommonlyusedSNMPobjectsinthe
TrangoLINKGigaPlussystem.AcompletelistingcanbefoundinAppendixD.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
55
AcopyoftheMIBfilesforthecurrentfirmwareversioncanbeobtainedbycontacting
TrangoTechnicalSupport.
CommonObjectsforMonitoringandControl
GigEBandwidthMonitoring
gigeEth1InOctets:NumberofoctetsofpayloadreceivedonGigEport1(copper).
gigeEth2InOctets:NumberofoctetsofpayloadreceivedonGigEport2(copper).
gigeEth3InOctets:NumberofoctetsofpayloadreceivedonGigEport3(SFP).
gigeEth4InOctets:NumberofoctetsofpayloadreceivedonGigEport4(SFP).
gigeEth1OutOctets:NumberofoctetsofpayloadtransmittedonGigEport1
(copper).
gigeEth2OutOctets:NumberofoctetsofpayloadtransmittedonGigEport2
(copper).
gigeEth3OutOctets:NumberofoctetsofpayloadtransmittedonGigEport3
(SFP).
gigeEth4OutOctets:NumberofoctetsofpayloadtransmittedonGigEport4
(SFP).
RFMonitoring
rfInOctet:NumberofoctetsofpayloadreceivedfromtheRFport.
rfOutOctet:NumberofoctetsofpayloadtransmittedtotheRFport.
rfEthernetInPackets:NumberofoctetsofpayloadreceivedfromtheRFport.
rfEthernetOutPackets:NumberofEthernetpayloadpacketstransmittedtothe
RFport.
rfRSSI:TheReceiveSignalStrengthIndicationindBmtheunitreceivesfromthe
ODU.CommonlyreferredtoasReceiveSignalLevel(RSL)
LinkStatusTraps
Varioustrapsaredefinedasfollows:
trapReboot:trapistriggeredwhentheunitisrebooted.
trapStartUp:trapistriggeredwhentheunitbootsup.
trapBackupLink:traptriggeredwhenthebackupstatuschanges.
trapBackupTakeover:ThetrapistriggeredwhentheBackupunithastakenover.
trapModemLockThistrapwillinformyouwhenthereisachangetothelink
lock.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
56
trapDownShiftThistrapwillinformyouwhenthemodulationoftheradiohas
shifteddowned.
TrangorecommendsmonitoringRSSI,MSE,EthernetTraffic(gigeEthOctets),Temp,and
modemlockasaminimumforthoroughmonitoringofthelink.Additionalobjectsand
trapscanbeaddedtothemonitoringsoftwareasrequired.PleasereviewAppendixD
MIBforacompletelistingofMIBObjectsandTraps.
UnderstandingandfamiliarizationofSimpleNetworkManagementProtocol(SNMP)
conceptsandsoftwareplatformsarerequiredtoutilizeSNMPmanagementofthe
TrangoLINKGigaPlussystem.
DuetothelargenumberofprogramsavailableforSNMP,Trangodoesnotprovide
supportofSNMPsoftwarepackagesorNMSsystems.Somecommonitemstotrywhile
havingissuesmonitoringspecificOIDsare:
ProperlyloadtheMIBsintoyoursoftware
Tryaddinga.0attheendoftheOIDstring
FirmwareUpgrade
ThefirmwareontheTrangoLINKGigaPluscanbeupdatedtoanewerversionthrough
IBMorOBMEthernetPorts.Afirmwarereleaseconsistsofuptotwofileswhich
containstheappropriatesoftwarefilesthatareloadedontotheIDUandODU:
IDUOSImageFirmwareFile
<idu_GigaPlus_<version>.tar.gz>
ODUImageFirmwareFile
<odu_fw.bin>
IfonlytheIDUfirmwarewaschangedthentheODUfirmwaredoesnotneedtobe
updated.
Beforebeginningtheupdateprocedure,becertainthatallrequiredfileshavebeen
downloadedtoaneasilyaccessibledirectoryonyourlocalharddrive.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
57
UpgradeProcedureTFTP
ALWAYSCONSULTTHEUPGRADEINSTRUCTIONSTHATAREINCLUDEDWITHANEWFIRMWARE
RELEASEASCERTAINFILESMAYNOTBEREQUIREDFORANUPGRADE.
1) Placethefirmwarefilesinaneasilyaccessibledirectorypathonyourcomputer.
2) TelnetintotheradiobyClickingonStartmenuthenRUN.Thefiguresusethe
defaultIPaddress;youmustusethecorrectIPaddressfortheTrangoLINK
GigaPlus.
Figure15WindowsStart&Telnet
3) Attheloginenteryourusernameandpassword.Theusernameisadminand
defaultpasswordistrango
4) Enterconfignodebytypingconfigandenteringyouwriteaccesspassword.
Thedefaultconfignodepasswordistrango
5) Enablethetftpdaemonusingthetftpdcommandasshownbelow.
Loginas:admin
Password:
TrangoSystem:TrangoLinkGigaPLUSCommandLineInterfacev1.3
(CLIview)#config
Password:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
58
(CLIconfig)#
(CLIconfig)#tftpdon
tftpd:on
SUCCESS
(CLIconfig)#
6) Openacommandprompt(orotherCLIinterface)windowonthePCwherethe
newfirmwareisbeingstoredandaccessthedirectorythatyouextractedthe
firmwarefiles.
C:\CDFirmware
C:\Firmware
7) UsingtheTFTPcommandlinetool,uploadthefirmwarefile.Thetftpsyntaxand
anexamplearebelow.
TFTP[i]host[GET|PUT]source[destination]
C:\firmware>tftpi192.168.100.100putidu_gigaplus_v13.tar.gz
Transfersuccessful:1951744bytesin15seconds,130116bytes/s
8) Oncethefilehasbeentransferredsuccessfully,logbackintotheunitandapply
theupdatesintotheFLASHmemoryusingthebootimageupgradecommand
fromtheconfigmode.Eachfirmwareneedstobeupgradedontheunitusingthe
bootimageupgradecommand.
(CLIconfig)#
(CLIconfig)#bootimageupgradeidu
NOTE:THEBOOTIMAGEUPGRADECOMMANDMUSTBEALLOWEDTO
COMPLETEBEFORETHESYSTEMISREBOOTED.IFTHESYSTEMISREBOOTED
DURINGTHEWRITINGOFTHEIMAGETOFLASH,THEFLASHMAYBECOME
CORRUPTWAITFORTHESUCCESSINDICATIONBEFOREPROCEEDING.
IftheODUfirmwarewasalsobeingupgraded,theODUfilewouldbetransferred
totheGigaPlusODUusingthesamemethodastheIDUfile.Afterloadingthe
file,thebootimageupgradeoducommandwouldbeusedtowriteittoFLASH.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
59
(CLIconfig)#bootimageupgradeodu
9) Arebootoftheradioisrequiredtoloadthenewimageafterupgrade
(CLIconfig)#reboot
Theupgradetimevariesdependingupontheimagesandthesizeoftheimage.
ThefirmwarecanbeverifiedbyloggingintotheradioviatheCLIthroughtheversion
commandorWebbrowserversionpageundertheFirmwareVersionsection.
TheCurrentfirmwareisthecurrentlyrunningfirmware.Thefirmwarewhichwas
replacedwillbelocatedinthepreviousimages.
UpgradeProcedureFTP
ToperformthefirmwareupgradeusingFTP,usetheftpcommandtoloadtheimages
intomemory,thenthebootimageupgradecommandsjustaswiththeTFTPmethod.
TheFTPmethodismuchfasterandhasbuiltinerrorchecking.
AllthatisneededistheIPaddressoftheftpserver,ausername/password,andthe
filenametobeuploaded.Thenewfiletobeuploadedshouldbeplacedontheserver.
Theftpserverwillpromptforthepasswordbeforeallowingaccess.
1) Putthenewsoftwarefilesontheftpserverusingtheftpputcommandfroma
localcomputer(thesecommandsarenotdonefromtheTrangoequipment).
ftp>put<sourcefile><destination>:
The<source>willbethefilenameonly.The<destination>willincludebothpathandfile
name.
2) Afterputtingthefileontotheserver,logintotheGigaPlusandruntheftp
commandfromthecommandlineasfollowstoopenaccesstotheserver:
ftp<server_ip><user_name>
password:xxxxxxx
Ifpromptedforthepasswordmultipletimes,checktheconnectivitytothe
serverbypingingtheFTPserverIPaddressfromthedebugprompt.
3) Next,getthefilefromtheFTPserverbytypingthegetcommandfromtheftp
prompt.
ftp>get<file_name>
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
60
4) Logoutoftheftpsession
ftp>logout:logoutofftpsession.
5) Runthebootimageomuand/orbootimageoducommandasrequired.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
61
CapacityUpgrades
TheGigaPlusspeedcapacityisstandardat100Mbps.Toupgradethecapacity,an
alphanumerickeywillberequired.ThiskeycanbepurchasedfromyourTrangosales
representative.
ToupdatethecapacitykeyfromtheWeb,copyandpastethekeyintotheSpeed
LicensefieldontheLinkSetupPage.Clickthesubmitbutton.Ifthelicenseisaccepted,
thewordEnablewillbedisplayedasshownbelowandreplacetheblankfield.
Figure16CapacityUpgradeinLinkSetupPage
Thecapacitykeycanalsobeenteredusingthelicensecommandfromthecommand
lineinterface.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
62
5.0 LinkPlanning
Thissectiondescribestheprocessthatoccursbeforeinstallingandsettingupan
GigaPlusmicrowavebackhaullink
Frequency/PathPlanning
Mostmicrowavelinksuselicensedspectrumthatrequiresthirdpartycoordinationto
ensureminimalinterferencewilloccurtonearbylicensedspectrumusers.Toensure
success,apathanalysismustbedoneforeachlinkthatisbeingconsidered.Antenna
heights,systemgain,rainregionandterraindataareevaluatedtodeterminethe
reliabilityofthelinkovertimeandchangingweather.
Trangowillrunpathanalysisforitscustomersusingindustrystandardsoftware,
evaluatedifferentequipmentoptionstoachievethecustomergoals,andassistthe
coordinationprocess.
SiteSelection
AfterthePlanningphaseiscomplete,itisessentialthattheproposedsitebephysically
evaluatedbytheoperatortoensurethatnobuildingsorvegetationhascrossedintothe
Fresnelzonethatwouldaffectoperationalreliability.
Itisnotuncommonfortallbuildingstobelocatedinwhatwouldotherwisebeaperfect
nonblockedlineofsightpathbasedonterraindata,buttoooftenthisisdiscovered
whentheinstallationisbeingperformed.
Thesitemustalsobeevaluatedforpowerandshelterprovisions.
Licensing
Licensingofspectrumistypicallydoneonanindividualpathbasis.IntheUS,theFCCwill
grantlicensesfor11yearsforpathsthatdonotinterferewithotherusersafterthe
coordinationandfeeshavebeenpaid.
ContactTrangoformoreinformationontheabovetopics.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
63
6.0 Installation
ThissectiondescribestheinstallationtoensurethattheGigaPlusunitsarecorrectly
installed.Failuretofollowtheseproceduresmayresultindamagetotheequipment
andvoidthefactorywarranty.
Safety
Installingmicrowaveequipmentcanbedangerous.Pleasetakethefollowing
precautionswheninstallingorperformingmaintenanceontheequipment.
EquipmentProtrusions:Theequipmenthasbeendesignedtobefreeofunnecessary
protrusionsorsharpsurfacesthatmaycatchorotherwisecauseinjuryduringhandling.
However,alwaystakecarewhenworkingonoraroundtheequipment.
LaserandFiberOpticCableHazards:TrangofiberopticSFPModuletransmittersare
IEC608251/21CFR10401ClassIcompliantandpresentnodangertopersonnelin
normaluse.However:Donotlookintoactiveunterminatedopticalportsorfibers.If
visualinspectionisrequiredensuretheequipmentisturnedoffor,ifafibercable,
disconnectthefarend.Followthemanufacturer'sinstructionswhenusinganoptical
testset.Incorrectcalibrationorcontrolsettingscouldresultinhazardouslevelsof
radiation.Protect/coverunconnectedopticalfiberconnectorswithdustcaps.
Placeallopticalfibercuttingsinasuitablecontainerforsafedisposal.Barefibersand
fiberscrapscaneasilypenetratetheskinandeyes.
LiftingEquipment:BecarefulwhenhoistingorliftingtheODUoritsantennaduring
installationormaintenance.TheGigaPlusHPODUisnominally12lbs.However,
antennaswiththeirmountinghardwarecanweighinexcessof100kg(220lb)and
requirespecializedliftingequipmentandanoperatortrainedandcertifiedinitsuse.
ProtectionfromRFBurnsTrangoODUs:TrangoGigaPlusODUsdonotgenerateRF
fieldsintenseenoughtocauseRFburns,however,installers/operatorsshouldcomply
withthefollowingcautions:
1) Itishazardoustolookintoorstandinfrontofanactiveantennaaperture.Do
notstandinfrontoforlookintoanantennawithoutfirstensuringtheassociated
transmitterortransmittersareswitchedoff.
2) DonotlookintothewaveguideportofanODUwhentheradioisactive.
ProtectionfromRFBurnsTowerSite:WhentheGigaPlusODUistobeinstalledwhere
existingantennasarelocated,avoidexposuretopotentiallyharmfullevelsofRF
radiationfromtheseantennasby:
1) DeterminingtheRFexposurerisk.Ifnecessaryaskthestructure/towerowneror
operator.Whennecessary,wearaprotectivesuitorhavethetransmitter(s)
switchedoffforthedurationoftheinstallation.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
64
2) Donotstandinfrontoforlookintoanyantennas.
SafetyWarnings:Whenapracticeorprocedureposesimpliedorpotentialharmtothe
userortotheradioequipment,awarningisincludedinthismanual.
AirflowRequirements:Installationsmustbemadesotheairflowrequiredforsafeand
correctoperationofTrangoequipmentisnotcompromised.FortheGigaPlusODU,
unobstructedairpassagemustbemaintainedtoallsidesoftheunit.FortheGigaPlus
IDU,thebackoftheunitmustbekeptcleartoallowthefantooperateproperly.
CircuitOverloading:WhenconnectingtheGigaPlus,determinetheeffectthiswillhave
onthepowersupply,circuitprotectiondevices,andsupplywiring.CheckGigaPlus
powerconsumptionspecificationsandthesupplycapabilityofthepowersupplysystem.
Thischeckofcapacitymustextendtothedcpowersupplyandnotjusttoan
intermediateconnectionpoint.
PowerSupplyEarthing:48Vpowersupplyearthmustbeconnecteddirectly
toabondingjumperfromanearthingterminalbarorbus.
ElectrostaticDischarge(ESD):ESDcandamageelectroniccomponents.Evenif
componentsremainfunctional,ESDcancauselatentdamageand/orprematurefailure.
AlwayswearproperESDgroundingstrapswhenhandlingortouchinganyPCB
assemblies.ConnectyourESDgroundingstraptothegroundconnectorontheODUor
IDUunitsasapplicable
FiberOpticCables:Handleopticalfiberswithcare.Keeptheminasafeandsecure
locationduringinstallation.Donotattempttobendthembeyondtheirminimumbend
radius.Protect/coverunconnectedopticalfiberconnectorswithdustcaps.
GroundConnections:Reliablegroundingofthesystemmustbemaintained.Referto
instructionsinthismanualforgroundingoftheODU,ODUcable,lightningsurge
suppressor,andIDU.
LightningSurgeSuppressor:TheGigaPlusIDUtoODUIFcablemustbefittedwithsurge
suppressorstopreventdamagetoequipment.Seetheinstallationsectionforfurther
details.
MainsPowerSupplyRouting:GigaPlusDCpower,T1/E1,Ethernetdataand
managementcablesarenottoberoutedwithanyACmainspowerlines.Theyarealso
tobekeptawayfromanypowerlineswhichcrossthem.
AmbientTemperature:TheambienttemperaturerangefortheGigaPlusODUis40to
+65Celsius,and5to+55CelsiusfortheIDU.Toensureoperationandtomaximize
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
65
longtermcomponentreliability,ambienttemperaturesmustnotbeexceeded.
Operationalspecificationcomplianceisnotguaranteedfortemperaturesoutsidethis
range.
MechanicalLoading:WheninstallingtheGigaPlusODUandantenna/remotemounton
atowermountorbuilding,ensurethemountissecurelyanchoredfirstandcansupport
thefullloadoftheradiounitandantenna.Ensurethattheadditionalloadingofan
GigaPlusODUwillnotcauseanyreductioninthemechanicalstabilityofthemount.
PowerSupplyConnection:TheGigaPlusIDUhasthepositivepinonitsdcpowersupply
connectorconnecteddirectlytothechassis,whichisinturnconnecteddirectlytothe
earthgroundthroughthetowerleg.TheGigaPlussystemmustbeusedwitha48Vdc
powersupplywhichhasapositiveearth;thepowersupplyearthconductoristhe
positivesupplytotheIDU.
1) Theremustbenoswitchingordisconnectingdevicesinthisearthconductor
betweenthedcpowersupplyandthepointofconnectiontoaGigaPlussystem.
2) ThepowersupplymustbelocatedinthesamepremisesastheGigaPlussystem.
3) AllwiringwhichiscarryingpowertotheGigaPlusIDUfromthepowersupply
mustbelargerthan18AWGandshouldbetwistedtoreducenoiseintotheIDU.
PowerSupplyDisconnect:Anappropriatepowersupplydisconnectdeviceshouldbe
providedaspartofthebuildinginstallation.
RackMountTemperatureConsiderations:IftheGigaPlusIDUisinstalledinaclosedor
multiunitrackassembly,theoperatingambienttemperatureoftherackenvironment
maybegreaterthanroomambient.Themaximumambienttemperatureof+55Celsius
appliestotheimmediateoperatingenvironmentsurroundingtheIDU,whichifinstalled
inarack,istheambientwithintherack.
RestrictedAccess:TheGigaPlussystemmustbeinstalledinrestrictedaccesssites.The
PoEunitandassociatedpowersupplymustbeinstalledinrestrictedareas,suchas
dedicatedequipmentrooms,closets,cabinets,orthelike.Accesstothetowerand
ODU/antennalocationmustberestricted.
Note:ForUSA:InrestrictedaccessareasinstalltheGigaPlussysteminaccordancewitharticles11026
and11027ofthe2002NationalElectricalCodeANSI/NFPA70.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
66
InstallationProcess
Thestandardprocedureforinstallingtheequipmentisasfollows:
1) Installantennaperantennainstallationmanual
2) InstallGigaPlusPowerSupplyandIDUinrack
3) InstallODUonantennaatbothends
4) InstallIFcablingandsurgesuppressors
5) Alignantennas
6) Proceedtocommissioning.
CAUTION:GigaPlushasnouserserviceableparts.Onlyfactorycertifiedpersonnel
shouldmakeanychangesorrepairstotheunits.
PreparingforInstallation
Tools
Thefollowingtoolsarerequiredforinstallation:
AdjustableOpenEndedWrench
LMR400cable
NMaleconnectorforLMR400
LMR400stripppingtoolorrazorblade
LMR400cablecrimptool
#2Flatscrewdriver
#2PhilipsHeadscrewdriver
Stranded18AWGwireforpowerconnection
Stranded12AWGwireforODUandIDUgroundconnections
WireInsulationstrippersforgroundandpowerwire
Terminalcrimpersforgroundandpowerwire
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
67
GroundingOverview
GroundingoftheIFcableshouldbedoneatthebaseofthetowerandneartheODU
usinggroundingkitssuppliedbyTrango.Inaddition,lightningsurgesuppressorsshould
beusedtopreventdamageduetonearbylightningstrikes.AntennaandODUshouldbe
installedatleast10feetbelowthetopofthetowertopreventdirectlightningstrikes.
AGroundwireofAWG12orlargershouldbeusedandgroundedtoanEarthgrounded
towerlegorBusBarbeforeentryintotheshelter.Figure16showstheoverallground
design.
Figure17SiteBasedGroundingDiagram
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
68
PowerSupplyInstallation
TheGigaPlusrequiresa48VoltpowersupplytopowerboththeIDUandtheODU.
Trangorecommendsthe48VDC,1Urackmountpowersupply(part#PSUPPLY1U
48).ThispowersupplycansupportuptotwoGigaPlusIDUsandODUsandisshown
below:
Installthepowersupplyinatemperaturecontrolledshelterorstandard19inchrack
usingtheholesprovided.
NOTE:Ensurethatonlya48VoltSupplyisusedandthatthewiringiscorrect.Ifa+48
VDCsupplyisusedandtheEarthgroundiswiredtothenegativeterminalshownin
thefigure,permanentdamagetotheunitmayoccur.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
69
AntennaInstallation
Antennasaretypicallyinstalledandarecoarsealignedusingeithervisuallyorwiththird
partyequipment.Alternatively,someoperatorsprefertoinstalltheradioequipment
ontotheantennapriortoinstallingtheantennaontherooftoportower.
Consultthespecificantennamanualfortheantennabeingusedfordetailedinstallation
instructions.
TheLinkConfigurationsectioncoversthealignmentoftheantennas.
InstalltheIDU
TheIDUissuppliedwithmountingbracketsandscrewsforinstallationintoastandard
19inchrack.TheIDUisprovidedwithagroundlugthatshouldbeconnectedtotherack
groundwithashortlengthofstrandedcopperwiretoensurealowimpedancepathto
ground.WhentighteningscrewsfollowtherecommendedtorqueintheTablebelow
Screw or Nut
Torque (in-lbs)
Size
4-40
6
6-32
12
8-32
22
10-32
37
-20
65
Table12RecommendedTorque
AsingleIDUwiththeRackEarsinstalledisshownintheFigurebelow.Itis
recommendedtoalwaysinstalltheIDUontheleftsidetoreducethelengthofthe
groundingwiretotherack.
Figure18IDUwithRackEarsinstalled
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
70
Connectingpower
TheGigaPlusissuppliedwithathreepositionlockingterminalblockforconnectingthe
48VDCpowersupply.ThemiddlepositionisEarthGroundandtheoutertwopositions
are48VDC.SeetheFigurebelow.
Figure19PowerConnectiononFrontPanel
Althoughonlyoneofthe48VDCconnectionsisrequired,dualpowersuppliescanbe
usedtoprovideredundancybyconnectiontheleftpositiontoonesupplyandtheright
positiontotheothersupply.
Internaldiodespreventcurrentfromflowingthewrongdirectioninthecasethatoneof
thepowersuppliesshouldfail.Undernormaloperationthecurrentwillbedivided
betweenthetwosupplies.
Asmentionedpreviously,thepowersupplywiresshouldbetwistedtoimprovethe
noiserejectionofthesystem.
Thewiringusedshouldbetwostrandedcopperwiresofasizenosmallerthan18AWG.
Thewiresshouldbetwistedtogethertoreducesusceptibilitytonoise.Atleastoneturn
perinchisrecommended.Tightenthetwo#2screwstothechassisafterinstallationof
theconnectortopreventitfrompullingout.
48V(2positions)
Ground(+)
Figure2048VDCPowerConnectorWiring
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
71
FerriteInstallation
TheIDUshipswithaferrite(Figure21)toreducenoiseenteringtheunitthroughthe
powercable.Toinstalltheferrite,loopthepowercablethroughatleastonceandclose
theferrite.BesuretoinstalltheferriteascloseaspossibletotheIDUpowerplugas
showninFigure22toimprovethenoiserejection.
Figure21Ferrite
Figure22FerriteInstalled
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
72
1+1HotStandbyIDUInstallation
Theinstallationofthe1+1HotStandbyissimilartothe1+0installation,exceptthe
installationisrepeatedforthesecondstandbyunitwhichismountedintheracknextto
themainunit.Thedummypanelisremovedinthiscase.
CBLDATRIU3
Figure231+1HotStandby(IDUs)withCBLDATRIU3
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
73
HPODUInstallationonAntenna
TheODUportionoftheGigaPlusutilizesaslipfitconnectionthatmakesinstallation
simple.TheODUsarealldesignedtomounttoacircularwaveguideantennaor
combinerwiththeexceptionofthe6GHzmodels.
For7to40GHzmodels,simplyrotatingtheODUwillchangetheantennapolarization
beingused.
AntennaO
RingSeal
HPODU
Waveguide
Antenna
Circular
Waveguide
port
Figure24AntennatoHPODUSlipFitWaveguideconnection
AfterinstallingandsecuringtheantennatheHPODUcanbeinstalleddirectlyonthe
backoftheunit.First,determinewhichAntennapolarizationwillbeusedandensure
thatthepolarizationindicatorisatthetopoftheunit.
PolarizationIndicatorsTheletterVisdiecastontheODUhousingperimeterto
assistinmountingtheODUtotheantennainthecorrectpolarization.
ForverticalpolarizationtheVshouldbeatthetopoftheunitasshownintheFigure
below,andforhorizontalpolarizationtheVshouldbeatthesideoftheunit.TheIF
connectorshouldbepositionedtowardsthelowerrightforverticalandlowerleftfor
horizontalpolarization.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
74
Vpolarization
indicatorattop
Figure25PolarizationIndication
CovertheantennaOringwithsiliconegreasepertheAntennamanual.Failuretodo
thismayresultinadamagedOringandsubsequentdamagetoorwaterintrusioninto
theantennaorODU.
GentlyslidetheODUontotheantennaandclipthefourspringloadedlatchestothe
antennaclipsasshownbelow.Thelatchesshouldbeverysnugandclickintoplace.If
thereisdifficultyclosingthelatches,thencheckthewaveguidefordebrisorforeign
matteraroundtheperimeter.
Securethelatchesthathaveeyeletswithlocksifdesired.
Latchwith
Eyelet
Figure26Latch
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
75
ForHP06yyyyzzandHP06yyyyzzmodels,boththeantennasandradiosusea
rectangularwaveguideopeningonthesameslipfitdesign.Thestandardpolarizationis
suppliedasVertical.Tochangethepolarization,theantennamustbechangedfrom
verticaltohorizontalbyrotatingeithertheantennaortheantennawaveguideport.
Consulttheantennainstallationmanualformoreinformation.
IFCableInstallation
GigaPluscansupportupto1000footcablerunsbetweentheIDUandODU.
LightningMitigationRecommendationsAsshowninthegroundingdiagram,Trango
stronglyrecommendsinstallingLightningarrestorsataminimumtwopointsintheIF
Cablerouting:
1) Attheclosestpointoftheradiopossible
2) Attheentrypointtothebuildingorequipmentshelter
3) Foroptimumprotection,Trangorecommendsinstallingatevery
5075ft
Theseconnectionsshouldbesecuredtothetowerorpoleatapointwherethereall
paint/platinghasbeenremovedtoensurealowimpedancepathtoground.NOTE:
thereisnoguaranteethatuseofthesearrestorswillpreventLightningdamagetothe
radioorotherelectronics,butitisprudentsystemdesigntoaggressivelymitigatethe
effects.
CableLengthRecommendationsTrangorecommendsthattheIFCablebeinstalled
witha2ftserviceloopnexttoeachconnector(i.e.belowtheODU/LightningArrestor,
nexttotheIDU,etc.)toallowforreplacementterminationsinthefuture.
CableConnectivityTheIFCablecanbeconnectedtotheODUandIDUwithrightangle
Nadapters(femaletowardsthecableandmaletotheIDU/ODU)whichpreventthe
bendradius(minimum1inch)fromobstructingcabinetdoors.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
76
Figure27RightAngleNConnectorMount
CableDressRecommendationsProperlysecuringtheIFCabletothetowerorpole
structureisimportantsincepoorlydressedcablescanbeabradedbythefrictionofwind
actionandcableconnectioncanbedegradedovertimebythesamestresses.When
securingtheIFCabletothetowerorpole,Trangorecommendsusingtiewrapsthatare
UVresistant(black)tominimizedeterioration.Tiewrapsshouldbeatleastinwide
andpulledonlyastightasneededtosnugthecabletothestructure.Narrowtiewraps
orovertighteningatiewrapcancompromisetheinternalstructureofthecoaxand
degradeperformance.TheIFCableshouldbesecuredtothetowerormountingpoleat
leastevery3to6ftwithtiewrapsorotherapprovedmethods.HangerAssembliesand
CableClampsareofferedbytowercompaniesthatcanprovideanevenmorerigid
attachmentforhighwindenvironments.
CableTerminationsRobustcableandcableconnectionsareCRITICALtothelongterm
performanceofthelink.Anycompromiseinmaterial,connectionprecision,or
weatherproofingmayresultinproblemsthataredifficulttofaultisolateandonly
emergeafterthelinkhasbeenexposedtothenormalstressesoftemperature,rain,and
winds.
CableTypeTrangostronglyrecommendstheuseofqualityLMR400cableandtopof
thelineconnectorscomplimentedbywelltrainedinstallationpersonnelfollowing
manufacturersinstructions.Othertypesofcablemaynothaveadequateshieldingand
maycauseorreceiveoutsideinterference.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
77
WeatherProofingCabling
Itisimportanttoproperlysealeachantennaconnectiontoprotectagainstmoistureand
corrosion.TrangoSystemsrecommendsusingCoaxSealwhichshouldbeappliedover
theODUNTypeconnector.CoaxSealisagumliketapewhichisappliedbywrapping
aroundtheconnectorandthencompressed/moldedtoformasinglecohesive
protectivecoveringovertheconnector.
ToproperlyapplytheCoaxSealproductfirstwraptheconnector/caseasshownin
Figure28:
Figure28WeatherProofingofcable
Secondly,compresstheCoaxSealproducttomoldintoasingleprotectivecovering
(Figure29):
Figure29Completeweatherproofingofcable
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
78
1+1HotStandbyODUInstallation
Theinstallationofthe1+1HotStandbyODUisdoneusingacombinerwhichhastwo
latchmountpositionsformainandstandbyODUs,andthelatchandboltmountfor
connectingtotheantenna.TheODUsmaybeattachedtothecombinerfirstandthe
combinerboltedandlatchedtotheantennanextasshownbelow.TwoIFcablesmust
beruntoeachofthetwoIDUs.
TheODUsmustbemountedusingthesamepolarizationfor1+1hotstandbyoperation.
FormoredetailseethemanualfortheSMCXXXXcombinerfamily.
Figure30ODUsonSMCcombiner(1+1)
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
79
7.0 LinkConfiguration
Thissectiondescribesthestepbystepprocessofconfiguringalinkandmakingsureitis
workingproperlybeforeinstallingandputtinglivetrafficonthesystem.
Thissectioncoversbasiclinkestablishmentforasinglelink.Thissetupmaybedoneon
thebenchorinthefield.Itishighlyrecommendedthatthebasiclinksetupbedoneon
thebenchtoavoidproblemswheninstallingtheequipment.
Specialbenchtestsetupsthatprovidemountingandfixedorvariableattenuation
betweentheRFportsoftheunitscanbeobtainedfromTrangoforthispurpose.All
stepsgivenshouldbeperformedonbothendsofthelink.
IMPORTANTNOTE:IfthelinkwasfactorypreconfiguredatTrangobeforeshipment,
thissectioncanbeskippedsincethepropersettingsarealreadyinplaceinsidethe
radiounits.
OnlytheIPaddressesneedtobechangedandtheOpmodeneedstobeenabledat
bothends.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
80
WebBasedConfiguration
WebBased1+0Setup
TheWebinterfaceisthemostcommonlyusedwaytosetupalink.Astepbystepguide
isshownbelow.ToaccesstheBrowserinterfacefromtheOutofBandmanagement
port,simplyconnecttotheunitusingEthernetcabling,openawebbrowserandenter
theIPaddressoftheradiointotheaddressline.ThedefaultIPaddressis
192.168.100.100
Figure31WebInterfaceLogin
Step1:Entertheusernameandpassword
Aloginwindowwillpopup,requiringtheusertoenterusernameandpassword(See
Figure33).Enterthedefaultusernameandpassword(user:admin,password:trango)
andclickOK.
Figure32WebLoginwithPassword
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
81
Oncetheusernameandpasswordareauthenticated,theSystemInfopagewillbe
displayedasshownbelow:
Figure33SystemInformationPage
Step2:SettheIPaddresses
a. ClickontheNetworkSettingsfolderandIP/IBMconfigurationpage.Set
theIPaddress,Subnet,andGatewaytotheaddressthatisdesiredforthe
OutofbandManagementPort.ClickSubmit.AtthispointtheWeb
sessionwillterminateandtheoperatormustloginagainusingthenewIP
address.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
82
Figure34IPConfigurationPage
b. SettheIPaddress,Subnet,andGatewaytotheaddressthatisdesiredfor
theOutofbandManagementPort.ClickSubmit.
AtthispointtheWebsessionwillterminateandtheoperatormustloginagainusingthe
newIPaddress.
Step3:SettheRadiolinkparameters
Alltheparametersshouldmatchthosesubmittedandapprovedbythelicensingagency.
c. SettheOdupowertoOnifitisnotalreadyon.
d. TurntheOpmodetoOffifitisnotalreadyoff.
e. SettheTXfrequency,bandwidth,modulationandtransmitterpower,
thenclickLinkSetup.Ingeneral,theFreqDuplexdoesnotneedtobe
changedunlessanonstandardspacingisbeingused.
f. Afterbothendsofthelinkaresetup,turntheopmodebuttononto
establishthelink.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
83
DonotadjusttheFailoversettingsunless1+1isdesiredSeetheSectiononsettingup
1+1fordetailonthis.
Figure35LinkSetupPage
Thelinkshouldnowbeestablishedbetweenthetwosides.TheActiveLinkindicators
willturngreenandtheRSSIandMSElevelswillchangeaccordingtothelinkdistanceor
attenuationused(bench)
ClicktheConfigSavebuttonatthelowerleftofanywebpageThismustbedoneon
bothsidesofthelink.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
84
WebBased1+1Setup
The1+1Setupisanextensionofthebasic1+0setup.1+1hotstandbyutilizestwo
GigaPlusunitsconnectedtoacombinertoallowsharingofanantennaateachendof
thelink.Oneoftheunitsateachendisthemain(active)unitandtheotherunitisin
standby,whichmeansthatitisreadytotakeovershouldtheactiveunitfail.
Thissectionassumesthatthephysicalinstallationhasbeendonealready.Returntothe
Installationsectionandconnecttheunitsina1+1configurationifrequired.
1) Followthestepsfor1+0onthemainlinkasdescribedabovewiththebackup
unitsturnedoff.
2) Turnthestandbyradiounitson,butensuretheopmodeisoffonbothtoavoid
disturbingtheactivelink.
3) OntheActiveLinkConfigPageclicktheFailoverModewithPortOffbutton:
Figure36FailoverModeSet
4) RepeatfortheActivelinkotherendunit.
5) ThedisplayfortheLinkstatusatthetopofthepageshouldchangetoshowboth
ActiveandStandbyunitsGreenforall4units.
6) Thesystemisnowsetupin1+1mode.Ifthemainlinkfails,theportswillbeshut
downonthemainlinkandthetrafficwillflowthroughthestandbylink,allowing
connectedswitchestoreroutethetraffic.
7) ClicktheConfigSavebuttonatthelowerleftofanywebpageThismustbe
doneonbothsidesofthelink.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
85
AdaptiveCodingandModulation(ACM)(Optional)
EnablingACMpermitsconfigurationoftheMSEImproveandDegradethresholds.Itis
recommendedtousethedefaultvaluesforbestperformance.SelecttheOnbutton
andthenclickonthesubmitbuttontomakethechangeifACMisdesired.
Figure37ACMSetup
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
86
AutomaticTransmitPowerControl(ATPC)(Optional)
EnableATPCtomaintainthereceivesignallevelataconstantlevel(targetRSSI)during
rainfading.ATPCistypicallyusedforveryshortrangelinksthatrequiretheinputlevel
intotheradiounittobereducedtoavoidsaturatingthereceiver.EnablingATPCresults
inatransmitpowerlevelonbothsidesofthelinkthatislowerthanthemaximumlevel
forthesetmodulation.Ifsetpowerwouldnormallybethemaximumlevelandthe
receiverwillnotbeoverdriven,itisrecommendedtoleaveATPCoffsinceitwillnever
beexercised.
Alarms,RPSandTelnet/TFTPDaemons
TheSystempagealsoallowstheindividualalarmsonthefrontpaneltobeenabledand
disabledfromthewebthesecanbeusedtoturnvariousotherdevicesonandoffas
longasthecurrentandvoltagelimitsoftherelaysarenotexceeded.Thetelnetandtftp
daemonscanalsobeturnedonandofffromthewebtocontrolaccesstothesystem.
TheRapidPortShutdowncanbeenabledordisabledhereaswelltoallowforrouting
protocolstoreroutetrafficifthelinkshouldgodown.
Figure38ATPCSetup/RPS/Telnetd/tftpd/alarms
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
87
EthernetConfiguration
TheEthernetpageallowstheindividualEthernettrafficportsonthefrontpaneltobe
enabled,disabled,andconfiguredfromthewebThetwomaintrafficportsGE1and
GE2canbeconfiguredfor10/100/100BaseToperation.IftheAutoNegoissetto
disable,theAutosensingfunctionisalsodisabledandthematchingsettingsmustbe
madeontherouterorswitch.OtherwisethelinkbetweenthedeviceandtheIDUvia
theEthernetcableforthespecificEthernetportwillbelost.
ThePrioritysettingallowsassigningpriorityforalluntaggedtrafficonthatportfrom0
to7(7beinghighest).Ifapreviouslytaggedpacketarrives,thepriorityfieldintheVLAN
tagCOSfiledwilltakeprecedenceovertheportpriority.Alluntaggedtrafficwillbe
giventheportpriority.
Ingressratelimitingallowstheoperatortorestrictthetrafficonanyoneporttoa
maximumrate,whichallowssomebandwidthshapingforeachport.
TheSFPports,GE3andGE4arefixedat1000BaseTbutcanaccommodatesingleand
multimodefibermodulesaswellascopper.
Figure39EthernetSetupPage
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
88
StatusMonitoringOverview
TheWebinterfaceprovidesmanywaystolookatthestatusofthetrafficflowingacross
thelinkandthehealthofthelink.ThefollowingFiguresshowthevariouscountersthat
canbemonitored.
SystemStatus
ThispagedisplaystheRadioandSystemStatus.TheSystemcontainsinformationonthe
Alarms,IDUtemperature,andfanstatus.TheRadiostatusdisplaysRSSI,MeanSquare
Error(MSE),BitErrorRate(BER),FrameErrorRate(FER)andODUtemperatures.The
temperaturesarethetemperatureinCelciusinsidetheODUandIDUunitsandwill
alwaysbehigherthantheoutsideairtempby1520degrees.
Figure40SystemStatusPage
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
89
LinkStatus
Containsthestatusonthemodem,EthernetPorts,T1/E1,andEthernetports.
Allthestatusindicatorsshouldbegreenwhenworkingproperly.Redusuallyindicates
thatanODUisoffornotconnected,orpossiblyarealhardwarefailure.AGreystatus
indicatorrepresentsanindicatorthatdoesnotapplyforthemodelofODUbeingused.
TheT1/E1PortStatusindicatorswillonlyturngreenwhentheT1/E1portisconnected
withavalidsignalformat.
Figure41LinkStatusPage
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
90
EthernetStatistics
ContainsstatisticalinformationonindividualfrontpanelEthernetports.Thesestatistics
areusedtodeterminetheerrorrateoftrafficandthetrafficflow.
IN:Meanstrafficbeenreceivedfromthedevice(Switch/Router)attachedtothe
particularGigEport.
OUT:MeanstrafficsentfromtheIDUtothedeviceattachedtotheparticularGigEport
Figure42EthernetStatisticsPage
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
91
RFStatistics
ContainssummarystatisticalinformationontheRFinandRFoutinterfaces.RFout
showsstatisticsforthetotalpacketsplusT1/E1andACMoverheadframestransmitted
tothefarendofthelink.RFinshowsthesameinformationforpacketsreceivedfrom
thefarend.
ThePortrateisupdatedevery20seconds.ThePortUtilizationisapercentageofthe
totalavailablecapacitybeingusedandisalsoupdatedat20secondintervalsfrontpanel
Ethernetports.Thesestatisticsareusedtodeterminetheerrorrateoftrafficandthe
trafficflow.
Figure43RFStatisticsPage
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
92
T1/E1Statistics
ContainsindustrystandardstatisticalinformationoneachT1/E1interface,updated
every20seconds.
Figure44T1/E1StatisticsPage
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
93
DiagnosticOptions
IDULEDallowssettingtheLEDsundertheTDMportstoindicatetheTDMportstatusor
representtheRSSIlevelreadfromtheODU.
LoopbackModeisusedfortroubleshootingandwillenablethetraffictobeloopedback
eitherattheIDUIFsectionjustbeforetheODUconnector,oratthedigitallevelinside
themodem.Thisfeatureisveryusefulforfaultisolationduringsetup.
DiagnosticExportgeneratesadiagnostic.binfile.Todownloadthisfile,theTFTP
functionoftheIDUmustbeenabled.ThenfromthePCscommandprompt,executethe
followingcommand:tftpi[IPaddressoftheIDU]getdiagnostic.binThefilewillhave
tobesubmittedtoTrangoProductSupportforprocessing.
ResetConfigwillrestoreallthesettingontheIDUtofactoryexcepttheIPstackandthe
licensekeys.
Figure45DiagnosticOptions
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
94
SystemLog
Thesystemlogrecordsevents,errors,andstatisticswithtimestampsattached.Thelog
levelcanbeadjustedviatheCLI.Loglevelsare0,1and2.Level0isusetoidentified
anyconfigurationsettingexecutedatbootupbytheIDUaswellasanyerrorsreported
atbootup.
Level1isusetoidentifyanyeventsthataretriggeredatthecommandline,likesaving
theconfigurationorchangingthefrequency.
Level2isusetoidentifiedlinkstatisticsonaperiodicbasis.Itisrecommendedthatthis
levelonlybeusedfordebuggingsincetheentiresyslogmemory(about1500entries)
willbeusedupquicklyandoldereventsmaybeoverwritten.
TheSyslogExportprocessissimilartotheDiagnosticExportprocess(SeeDiagnostic
Exportabove).Thenameofthefiletodownloadissyslog.txt
Figure46SystemLog
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
95
ConfigView
ConfigViewallowscompletedisplayofthesystemconfigurationandalsoexportingthe
configurationfileasarecordofthesystemsetup.ByclickingontheConfigExport
button,thesystemwillgenerateaconfig.txtfile.Followthesameprocedures
mentionedundertheDiagnosticExportsectionabovetodownloadtheconfig.txtfile.
Figure47ConfigView
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
96
UserSettings
AllowssettingthesystemremarkfortheIDUwhichisdisplayedatthetopofeveryweb
page,aswellaschangingtheLoginPasswordfortheweb(HTTP)interface.
Figure48UserSettings&Password
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
97
CommandLineInterface(CLI)BasedConfiguration
CLIBased1+0Configuration
Thissectioncoversallthebasicsthatarenormallyrequiredforsettingupthelinkusing
eitherthetelnet,SSH,orserialCOMporttoaccesstheunits.Stepbystepinstructions
withsessionexamplesaregiven.TheCLIinterfacehasmorefunctionsavailablethanthe
WebInterface.Simplytypethe?toseealistofavailablecommands.
Step1:ConnecttoEachUnitviaoneoftheCLIinterfaces
Inalltheexamplesgiven,telnetwasused,buttheloginprocedureissimilarforeach.To
logintoeachunitsusingthedefaultIPaddressof192.168.100.100.
Usethewindowstelnetprogramoranyothertelnetclientprogram.Whenprompted
fortheLoginenteradminandforpassword,entertrango.TheTrangoSystems
commandlineinterfaceapplicationshouldrespondasfollows:
Trango System:
Whenloggingintotheradiounit,theoperatoralwaysentersthe(CLIview)#node,from
whichonlystatusofthesystemcanbeseen.Tomakechangestosystemsettings,the
operatormustenterthe(CLIconfig)#nodeoftoallowchangestothesystemtobe
made.Typethecommandconfigandthepasswordtrango.Thepasswordcanbe
changedlater.
(CLI-view)# config
Password:
Step2:ChangetheOutofBand(OBM)ManagementIPAddress
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
98
ItisrecommendedtochangetheIPaddressonbothendsoftheradiofirst,before
installingthelinktoensurethatnoproblemswillbeencounteredaccessingtheunitsin
thefieldfromthedestinationnetworksubnet
TochangetheIPaddressofthesystem,firstchecktheipsettingsusingtheipcommand.
(CLI-config)# ipconfig
IP Address:
192.168.100.100
Subnet Mask:
255.255.255.0
Gateway IP:
192.168.100.1
ETH1 MAC:
00:01:de:81:65:44
ETH2 MAC:
00:01:de:81:65:45
Next,changetheIPaddressandsubnetmask.Thesystemwillnotberesponsiveafter
thechange.ReconnecttotheGigaPlususingthenewIPaddress.
10.14.1.41
Netmask:
255.255.254.0
SUCCESS
Afterreconnecting,changethegatewayaddressasnecessary.
(CLI-config)# ipconfig gateway 10.14.0.1
Gateway IP:
10.14.0.1
SUCCESS
Confirmthatthechangesaremade:
(CLI-config)# ip
(CLI-config)# ipconfig
IP Address:
10.14.1.41
Subnet Mask:
255.255.254.0
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
99
Gateway IP:
10.14.0.1
ETH1 MAC:
00:01:de:81:65:44
ETH2 MAC:
00:01:de:81:65:45
Step3:TurntheODUSectionoftheradioon
TypeodupowerontoapplypowertotheRadiosectionoftheunit.AftertheCLIreturns
thestatusofon,entermodeltoshowthemodels,serialnumbers,TRspacingand
transmitfrequencyrangeoftheunit.
(CLI-config)# odupower on
ODU Power enable:
on
SUCCESS
(CLI-config)# model
IDU Model:
IDU-GigaPlus-1
8480068
ODU Model:
HP2-23-1200-3A
C110301327
Tx Freq Min:
22000.00
Tx Freq Max:
22400.00
Freq Duplex:
1200.00 (MHz)
Step4:SettheTransmitterandReceiverCenterfrequency
Thecenterfrequencymustbewithintheminandmaxshowninthemodelcommand
andmustbeatleastoftheoccupiedtransmitterbandwidthawayfromthelimitsfor
properoperation.
EnterthetransmitfrequencyinMHz(theresolutionofthefrequencyis.250MHz).The
receivefrequencywillautomaticallybeprogrammedasfollows:
ForAmodels,RXFreq=TXfreq+FreqDuplex.
ForBmodels,RXFreq=TXFreqFreqDuplex.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
100
InsomecasestheFreqduplexcanbechanged,buttypicallythiswillnotbenecessary.
ChangingtheFreqduplexwillautomaticallychangetheRXfrequency.Theopmode
mustbeofftosetthefrequency.
Firstsetthelocalendtransmitfrequency:
22300.00 (MHz)
Rx Freq:
23500.00 (MHz)
Freq Duplex:
1200.00 (MHz)
Next,Setthefarendtransmitterfrequency(separatesessionwiththeotherradio)
(CLI-config)# freq 23500
Tx Freq:
23500.00 (MHz)
Rx Freq:
22300.00 (MHz)
Freq Duplex:
1200.00 (MHz)
Ifthesystemhasbeeninstalledandthefarendtransmitterisalsoonthelinkcanbe
checkedusingthelinktestcommand
(CLI-config)# linktest
LOCK
1>
RSSI
MSE
-45.00
-36.70
BER
0.00E+00
Step5:EnableAdaptiveCodingandModulation(ACM)(Optional)
IfACMisdesired,theacmenablecommandshouldbeusedonbothendsofthelink.
IMPORTANT:AftertheACMisenabledafterinitiallinkestablishment,thespeed
commandmustbereissued.
on
SUCCESS
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
101
Thetwostepsabovemustbedoneonbothendsofthelink,startingwiththeunitthat
doesnothaveoutputbandmanagementorwhichreliesontheGigaPlusIBM
connectionformanagement
Step6:SettheSpeedandModulation
Thespeedsettingmayrequirealicensekeyiftheresultingpayloadspeedisabove100
Mbps.Thecommandspeedshowsthecurrentmodulation,BandwidthinMHz,Symbol
RateinMsym/sec,andthepayloadspeed(capacity)inMbps.
(CLI-config)# speed
Modulation:
128QAM
Bandwidth:
20.00
Symrate:
17.42
Speed:
111.00
Step7:EnabletheTransmitters
Turnopmodeononbothendsofthelink.Thisenablesthetransmitterontheunit.
Aftertheopmodeisturnedon,theTXfrequencycannotbechangedunlessopmodeis
turnedoffagain.
(CLI-config)# opmode on
Opmode:
on
SUCCESS
Step8:Verifythelinkisworking
Runthelinktestcommandtoconfirmthatthelinkisrunningproperlyafterenabling
ACM.NoticethattheTxandRxmodulationlevelsarenowshown.Now,ifthelink
conditionsdegradeduetorainfading,eithertheTxorRxmaydownshiftduringthefade
event.Runningthelinktestcommandagainwillshowthelowermodulationsuchas
64QAM,32QAM,etc.forTxorRx.TheRSSIwillalsolikelychangeforrainfading,but
mayremainunchangedifthelinkdegradationisduetomultipath.Themodulation/RSSI
willautomaticallyreturntothesetvalueoncethefadingconditionhaspassed.
(CLI-config)# linktest
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
102
LOCK
1>
RSSI
MSE
BER
-38.00
-35.00
0.00E+00
Tx
128QAM
Rx
128QAM
Step9:Savetheconfiguration
Runtheconfigsavecommandtosaveallthesettingsthatwerechangedintonon
volatileFLASHmemory.Ifapowerinterruptionsshouldoccur,thelinkwillreestablish
itselfaftertheinterruptionisover.(assumesdefault_opmodeonwasenabledandthe
configurationsavedpriortothepowerinterruption).
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
103
CLIBased1+1HotStandbyConfiguration
Thissectionassumesthatthephysicalinstallationhasbeendonealready.Returntothe
Installationsectionandconnecttheunitsina1+1configurationifrequired.
Stepstoconfigure1+1HotStandby:
1) Followthe1+0configurationsectiontoestablishalinkbetweenthetwomain
endsofthelink,withthesecondpairofradiosturnedoff.Theantennasshould
bealignedatthispoint.
2) Forbothendsofthemainlink:
a. SetthefailoverfunctiontoONusingthefailovercommand.
b. Setopmodeon.
c. Setdefault_opmodeon.
d. Savetheconfigurationusingconfigsave
e. Powerbothendsofthelinkdown.
3) Bringthesecondlink(Standby)upusingthesameconfigurationasthemainpair.
a. SetthefailoverfunctiontoONusingthefailovercommandonbothends
ofthestandbylink.
b. Savetheconfigurationusingconfigsave
c. Powerbothendsofthelinkdown.
4) ConnecttheredundancycableCBLDATRIU3betweenthetwoIDUs.
5) Powerbothmainlinkup
6) Afterthelinkisestablished,powerupthesecondlink.
7) Aftertheelectionperiodexpires,thetwounitsateachend(activeandstandby)
willsyncupwiththeproperutypeandconfigurationsettings.
8) Verifybyrunningthefailovercommandandobservingthestatus.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
104
AntennaAlignment
AfterBasicSetupofthelink,theantennascanbealigned.
Aligningnarrowbeamwidth(<2deg)overlongdistancescanbeadifficultprocess
withouttheproperequipment,patience,andacarefulprocess.
UsingaGPScompassandthePathAnalysistoestablishacrudeazimuthandelevation,
theinstallationcrewcanmounttheAntennaAssemblyonthesupportingstructuresat
eachendofthelink.Oncetheantennasareinstalledandaroughantennaalignment
hasbeenestablished,thenthefinealignmentprocesscanbeginatoneendofthelink
(typicallythesitewiththesmallerantenna).
OnceonesideisalignedtoachievebestRSSI,MSE,andBERthentheoperatorcan
adjusttheothersidetoimprovethelink.Alignmentcanbedoneusingthelinktest
commandfromthecommandlineinterface,orthevoltageindicationfromtheBNC
connectorontheODU.
Figure49BNCConnectorforRSSIVoltage
RunthelinktestcommandwhilealigningtheantennaandlookfortheMSEtoimprove
(ahighernegativenumber)whileadjusting.Whenthelockstatuschangesto1,you
mayfinetunethealignmentwiththeLEDdisplay
AntennaAlignmentProcedure
1.
Ensurethatbothsidesofthelinkareconfiguredcorrectly.
2.
ConnecttothemanagementportoftheGigaPlus.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
105
3.
Logintotheendofthelinkthatisbeingaligned.
4.
Runlinktest99commandwhileadjustingtheantenna(s),andmonitor
theBNCoutputvoltageuntiltheexpectedvoltage/RSSIlevelisreached.
ThevoltageattheBNCwillrangefrom0.1Voltsat90dBminputlevelto
4.5Voltsat20dBminputlevel.UseavoltmeterandCBLDATRSSIto
monitorthevoltagewhileadjustingtheantenna.Thefollowingequation
canbeusedtodeterminetheRSLwithin3dBaccuracy
RSL(dBm)=15.77xVBNC91.58
BelowisatableshowingthevoltagetoRSLforconvenience.
Voltage
(Volts)
0.1
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
2.5
2.75
3
3.25
3.5
3.75
4
4.25
4.5
RSSI
(dBm)
90
87.6
83.7
79.8
75.8
71.9
67.9
64
60
56.1
52.2
48.2
44.3
40.3
36.4
32.4
28.5
24.6
20.6
Table13RSSItoVoltageConversion
5. OncesatisfiedwiththeRSSIreading,tightendowntheantennainthe
optimumposition.
6. ReplacethesealingcapontheBNCconnectorandtightenuntilitclicksinto
place.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
106
CLICommonTaskReference
SettinguptheInBandManagement(IBM)
TrangopreconfiguresthelinkswithIBMalreadysetupandenabled,howeveritwill
typicallybenecessarytochangetheIBMIPaddressesusedtofittheapplication
managementnetworkandifmanagementacrossthenetworkisdesired,aVLANmust
besetupontheattachedswitches.ThissectioncoversthesetupoftheIBM.
DisplaytheIBMsettings.IntheexamplebelowtheIBMisoff.
(CLI-config)# ibm
IBM Enable:
off
4085
IBM Port:
ge1-copper
IBM IP address:
172.16.1.1
IBM Netmask:
255.255.0.0
SUCCESS
EnableIBMusingthesettingspreloaded.
on
SUCCESS
ChangetheIBMIPaddressandsubnetmask.Eachendofthelinkshouldhavea
differentIPaddress,andinthecaseofmultipledaisychainedlinks,theIPsshouldallbe
different.
TrangoSystems,Inc.
172.16.1.2
255.255.255.0
GigaPlusUserManualRev1.3
107
SUCCESS
Verifythesettingsarecorrect.
(CLI-config)# ibm
IBM Enable:
on
4085
IBM Port:
ge1-copper
IBM IP address:
172.16.1.2
IBM Netmask:
255.255.255.0
Verifytheconnectiontotheotherendofthelinkbyenteringthedebugnodeandusing
thepingcommandinsidetheApexPlus.Intheexample,theotherendofthelinkhasan
IPaddressof172.16.1.1.
(CLI-config)# debug
Pingtheothersideofthelinkusingthepingcommandfromwithinthedebugnodeof
theradio.
# ping 172.16.1.1
PING 172.16.1.1 (172.16.1.1): 56 data bytes
64 bytes from 172.16.1.1: seq=0 ttl=64 time=6.672 ms
64 bytes from 172.16.1.1: seq=1 ttl=64 time=1.001 ms
64 bytes from 172.16.1.1: seq=2 ttl=64 time=0.979 ms
--- 172.16.1.1 ping statistics --3 packets transmitted, 3 packets received, 0% packet loss
round-trip min/avg/max = 0.979/2.884/6.672 ms
Note:Besidesping,Itshouldbenotedthatfromthedebugpromptatelnetsession
canberuntoconfigurethefarendifdesired.Itshouldbekeptinmindthatany
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
108
changethatwouldbreakthelinkwillresultinlossofcontroltothefarside.Changes
toparameterslikefrequency,speed,oropmodeshouldbedonewithcare.
Returntothecommandlineinterfaceusingtheclicommand.Uponreturningfromthe
debugprompt,thesystemwillbeintheviewnode,sotheusermustlogintotheconfig
nodeifanyfurtherchangesarerequired.
# cli
Trango System:
Returntotheconfignodeusingtheconfigcommand
(CLI-view)# config
Password:
CapacityLicenseActivation
Activatethetrafficcapacitylicenseifneeded.Licensekeysaretypicallyinstalledatthe
factorypriortoshipment.Shouldtheoperatorwishtoreenterthelicensekeys,usethe
licensecommandasshownbelow
(CLI-config)# license 2 <alphanumeric key>
License:
License 2
SUCCESS
AutomaticTransmitPowerControl(ATPC)Configuration(optional)
ConfiguretheAutomaticTransmitPowerControl(ATPC)ifrequired.ATPCistypically
onlyrequiredifthelinkissoshortthatthemaxtransmitpowercannotbeuseddueto
receiveroverload,orforregulatoryreasons.
FirstchecktheATPCstatus.IftheATPCisoffthentheATPCcanbeenabledusingthe
atpcenableoncommand.Intheexamplebelowthemaxpoweriscurrently19dBm
(CLI-config)# atpc
ATPC Enable:
on
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
109
19.00
Next,settheATPCmaxpowerbasedonthehighestmodulationthatwillbeused.Inthe
examplebelow,thehighesttransmitpowerthatwillbeusedis+17dBm,sotheatpc
max_powerissetaccordingly.
17.00
SUCCESS
(CLI-config)# atpc
ATPC Enable:
on
17.00
Next,setthetargetreceiverlevelthatwillbeusedtocontrolthefarendtransmitter
power.IftheRSSIistoohigh,thentheATPCsoftwarewillsendanATPCpowerdown
commandtotheotherendofthelink.
Thetargetrssimustbesetonbothendsofthelink,justastheATPCmaxpower.The
ATPCsoftwarewillstopsendingcommandstotheotherendofthelinkwhentheRSSIis
within+/2dBofthesettargetrssilevel.
(CLI-config)# targetrssi
Target RSSI:
-45.00
-40.00
SUCCESS
CheckEthernetandRFportStatistics
Runthestatusportcommand
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
110
ThiscommandshowsthecurrentEthernetportstatisticsandtoprovideconfirmation
thattheconnectiontothenetworkequipmentissetupproperly.Thesystemdefaultis
autonegotiate.Thege1andge2portsaremappedtothecopperports,andge3and
ge4aremappedtotheSFPdataports,andthege0portistheinterfacefromthe
internalswitchinsidetheODUtothemodem.
Thege0statisticsaretypicallynotmonitoredandaremadeavailablefor
troubleshootingpurposesonly.TheRFcountersindicatethestatisticsforthereceive
portandthetransmitport.
TheOctet/PacketcountsontheRFcountersmaybeslightlyhigherduetointernal
messagingbetweenthetwoendsofthelinkforinternallinkmanagement,andagain
theyareprimarilyfortroubleshootingpurposesanddonotneedtobemonitored
continuously.
MonitoringtheRFdropcountsisusefulfordeterminingiferrorsareoccurringoverthe
wirelessportionofthelink.
Theportrateandportutilization(percent)arealsousefulformonitoringsincetheycan
indicatealinkrunningatcapacity.Thesetwometricsaccountforthesumofallthe
Ethernetportsbeingused.
ge1
ge2
ge3
Enable:
on
on
on
on
Status:
off
off
off
off
Duplex:
full
full
full
full
full
Speed:
1000
1000
1000
1000
1000
362607
4535496
2698731294
4444
2617317006
2323868109
136
922671622
1719593480
3076730927
14415821
2308569723
652052464
135
136
CRC Errors:
20
CollisionError:
In Octets:
In Ucast Pkt:
In NUcast Pkt:
Out Octets:
Out Ucast Pkt:
ge4
nternal
on
on
TrangoSystems,Inc.
4280834626
OUT
3284730808
GigaPlusUserManualRev1.3
111
Total Pkt:
2328890117
653833881
20
N/A
Port Rate(Mbps):
Port Util(%):
Runthestatusclearcommand
AfterthelinkhasbeenestablishedandtheEthernetinterfacesarerunningproperly,the
countersmayallbecleared.Thisistypicallydonejustpriortothelinkvalidationphase
inwhichafixedamountoftrafficorpacketsarepassedoverthelinkoveraperiodof
timetoensurenodropsoccur.Thestatusclearcommandwillclearallportcounters
andtheBERcounters.
Runthesyslogclearcommand
Beforedeploymentitisagoodideatoclearthesyslogsothatonlyeventsafterthelink
wascommissionedarerecorded.Runthesyslogclearcommand.
(CLI-config)# syslog
Current 0:19:24:25.990
Viewthemodelinformationusingthemodelcommand
(CLI-view)# model
IDU Model:
IDU-GigaPlus-1
8480068
ODU Model:
HP2-23-1200-3A
C110301327
Tx Freq Min:
22000.00
Tx Freq Max:
22400.00
Freq Duplex:
1200.00 (MHz)
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
112
EnableTraps(Optional)
Trapscanbeusedtonotifyexternalnetworkmonitoringdevicesthatathreshold
parameterhasbeencrossed.Thresholdsreavailableforthefollowing:
RSSI
MSE
BER
FER
OMU_TEMP
ODU_TEMP
OUTPORTUTILIZATION(percentageofmaxavailable)
INPORTUTILIZATION(percentageofmaxavailable)
IfthresholdshavebeensetandSNMPTrapassignedasanaction,thecrossingofthe
thresholdwillgenerateatrap.
Thecurrenttrapinformationusingthetrapcommand.ThecurrenttrapmanagerIP
addressesareshownalongwiththeirindividualstatus:
(CLI-config)# trap
IP
Enable
Trap 1:
0.0.0.0
off
Trap 2:
0.0.0.0
off
Trap 3:
0.0.0.0
off
Trap 4:
0.0.0.0
off
Trap 5:
0.0.0.0
off
Setthetrap1managerIPaddressusingthetrapipcommandrepeatforadditional
trapmanageripaddresses:
(CLI-config)# trap ip 1 10.14.1.5
IP
Trap 1:
Enable
10.14.1.5
off
SUCCESS
Enablethetrapnumber1usingthetrapenable1ononcommandThetrapwillbe
enabledandthestatusshown:
CLI-config)# trap enable 1 on
IP
Trap 1:
TrangoSystems,Inc.
Enable
10.14.1.5
on
GigaPlusUserManualRev1.3
113
8.0 Troubleshooting
Thissectionprovidestroubleshootingadviceforproblemsthatmaybeencountered
duringsetupandnormaloperationofthesystem.
Symptom:NoLink(Lock=0duringlinktest)
1) TXFrequencymustEXACTLYmatchtheRXfrequencyontheremoteside.Typefreq
commandfromtheCLItoview.Verifythatthefrequenciesusedmatchthe
regulatorybody(FCCorequivalent)approvedfrequencies.
2) Opmodeisoff.Runopmodecommandtoview,andrunopmodeontoenable.If
theunitwasrebootedandthedefaultopmodeisnoton,theunitwillcomebackon
buttheopmodewillbeoff.Toprevent,rundefault_opmodeoncommandand
configsave.
3) Arethefrequenciesconfiguredcorrectlyoneachradio(TXandRX)?Highfrequency
ontheBsideandlowfrequencyontheAside..
4) IstheODUunitinstalledproperlyontheremotemount(remotemountapplications
only)?Thesystemunitwillonlyoperateinasingleorientationontheremote
mount.Followthedirectionsontheremotemounttoensurecorrectinstallation.
ThearrowsontheRemotemountmustbealignedwiththeVontheODU.
5) ArebothODUsattheendsofthelinkmountedonthesamepolarization?ODUs
mustbemountedwithmatchingpolarizationsateachendofthelink.Ifonesideis
mountedontheantennadifferentlythantheotherside,thelinkwillnotlockorthe
signallevelwillbe2030ormoredBlowerthanexpected.
6) IFACMisbeingused,ACMmaynotbeenabledonbothendsofthelink.Enablethe
ACMandresetthespeedoneachend.Thespeedmustbesetthesameonboth
ends.
MSEistoohighand/orbiterrorsareshowingwhenrunninglinktest
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
114
NOTE:MSE=32dBorloweristypicalfor256QAM,29isaworsenumberandisnot
typical
1) Isthetransmitterpowersettoohighforthecurrentmodulationbeingused.
Consultthelicenseinformationtoverifythatthepowerlevelisnohigherthanthe
maximumallowedforthehighestmodulationthatwillbeused.
2) TargetRSSIsetupmaybeincorrect.ItisbesttosetthetargetRSSIashighas
possiblewithoutoverdrivingthereceiverforthemostrobustoperation.Settingthe
targetRSSItooclosetotheRXsensitivitythresholdwillcompromisethelink
integrity.
3) ArebothGigaPlusODUsmountedonthesamepolarization?ODUsmustbe
mountedwithmatchingpolarizationsateachendofthelink.Ifonesideismounted
ontheantennadifferentlythantheotherside,thelinkwillnotlockorthesignal
levelwillbe30ormoredBlowerthanexpected.
4) IstheODUinstalledproperlyontheremotemount(remotemountapplications
only)?TheODUwillonlyoperateinasingleorientationontheremotemount.
Followthedirectionsontheremotemounttoensurecorrectinstallation.TheArrow
ontheremotemountmustlineupwiththeVontheODU.
5) Presenceofmicrowavetransmittersonsamefrequency(uncommon):Tocheckfor
possibleinterferencefromotherlicensees,turnofftheoppositeendtransmitterand
runtherssicommand.Thesignallevelshouldbe90orlower.Thelevelshouldbe
steadywithinadBorso.
ReceiveSignalLevelistoolow
1) TargetRSSIsetupmaybesetincorrectly(whenusingATPConly).Itisbesttosetthe
targetRSSIashighaspossiblewithoutoverdrivingthereceiverforthemostrobust
operation.SettingthetargetRSSItoolowwillresultinasignallevellowerthan
whatisexpectedifATPCisenabled.
2) ReportedRSSImorethan3dBofftheexpectedRSSI:Theremaybeanalignment
problemwithoneorbothantennas,especiallyifbothsidesofthelinkshowthe
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
115
samesymptom.Amisalignedantennaisoneofthemostcommoninstallation
problems.
Solution:Realigntheantenna(s).Opmodemustbeonattheremotesideofthelink
todoalignmentofthelocalside.EnsurethatATPCisoff.
3) ArebothODUsmountedonthesamepolarization?ODUsmustbemountedwith
matchingpolarizationsateachendofthelink.Ifonesideismountedontheantenna
differentlythantheotherside,thelinkwillnotlockorthesignallevelwillbe30or
moredBlowerthanexpected.
4) IstheODUinstalledproperlyontheremotemount(remotemountapplications
only)?Theradiounitwillonlyoperateinasingleorientationontheremotemount.
Followthedirectionsontheremotemounttoensurecorrectinstallation.TheArrow
ontheRemotemountmustlineupwiththeVontheODU.
RFLinkisgoodbutpacketlossisoccurring:
1) VerifytheduplexandspeedsettingsintheEthernetportarecorrect(100or1Gbit)
andmatchtheconnectedequipment,andthatnoCRCerrorsontheportare
occurring.
2) VerifythattheEthernetportsareconnectedproperly.TheGigaPlusfamilyofRadios
areportmapped,meaningthatthetrafficgoingintoEthernetport1onthelocal
sidewillonlyappearatport1oftheremoteside,localsideport2trafficwillappear
ontheremotesideport2,etc..
3) ChecktheEthernetcablesforcorrectwiring.If1000BaseTisbeingimplemented,
Cat5eorCat6cableshouldbeused.Ensurethatthecableisshieldedandproper
groundingisappliedtotheRJ45connector.
NodirectmanagementusingOutofbandport
IfyoucannottelnetintotheIDUoropenanHTTPbrowsersession,
1) CheckyourEthernetandpowercableconnections
2) Ensurepropercableisbeingusedcrossovervs.straightthroughcable.TheLEDson
theEthernetportshouldbeilluminated.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
116
3) CheckPCssubnettomakesureitisroutabletotheradiosIPaddress.
4) Ensuresnmpdisenabled
5) Ifafirmwareupgradewasjustperformedandonefiledidnotloadproperlyandthe
systemrebooted,youwilllosemanagement.PleasecallTechnicalSupportfor
furtherassistance.
NoRadioManagementconnectionoverthelink
1) VerifytheInBandmanagementissetupproperlyChecktoseeiftheIP
configurationiscorrect,theVLANIDissetandmatchesonbothends,andthatIBM
isenabled.
T1/E1Portsnotpassingtraffic
1) MismatchedT1ports,sincetheT1portsareportmappedT1port1onIDUonemust
beconnectedtoT1port1onthesecondIDU.
2) Ensuretheportisenabledusingthedatapathcommand.Thedatapathmustbeset
toEth+T1orEth+E1,theconfigsaved,andthesystemrebootedatbothsides.
3) VerifypinoutsoftheT1/E1RJ45connector
4) GigaPlusKeyPDHLicenseKeynotactivated
IftherearestillproblemspleasecontactTechnicalSupportat8583910010orEmailat
techsupport@trangosys.com
Beforecallingpleasemakesureyouhavethefollowinginformation.
SerialNumber
Descriptionoftheproblem
Stepstakensofartoresolvetheproblem
Commissioninglog
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
117
AppendixACommandLineInterfaceReference
ThisAppendixprovidesastandaloneguidetothecommandsavailablethroughthe
Telnet,SSH,andconsoleportoftheGigaPlus.
CommandKeyingOverview
KeyFunctions
TabAutocomplete
Completesapartialcommandnameentry.Whenyouenterauniquesetofcharacters
andpresstheTabkey,thesystemcompletesthecommandname.Ifyouenterasetof
charactersthatcouldindicatemorethanonecommand,thesystembeepstoindicate
anerror.Enteraquestionmark(?)immediatelyfollowingthepartialcommand(no
space).Thesystemprovidesalistofcommandsthatbeginwiththatstring.
DelorBackspace
Erasesthecharactertotheleftofthecursor.
Return
Atthecommandline,pressingtheReturnkeyperformsthefunctionofprocessinga
command.AttheMorepromptonaterminalscreen,pressingtheReturnkeyscrolls
downaline.
SpaceBar
Allowsyoutoseemoreoutputontheterminalscreen.Pressthespacebarwhenyou
seetheMorepromptonthescreentodisplaythenextscreen.
LeftArrow
Movesthecursoronecharactertotheleft.
RightArrow
Movesthecursoronecharactertotheright.
UpArrow
Recallscommandsinthehistorybuffer,beginningwiththemostrecentcommand.
Repeatthekeysequencetorecallsuccessivelyoldercommands.
DownArrow
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
118
Returntomorerecentcommandsinthehistorybufferafterrecallingcommandswith
theUpArroworCtrlP.Repeatthekeysequencetorecallsuccessivelymorerecent
commands.
DifferentNodeLevels
ViewNode
This is the default node the users log in. This is strictly for viewing configuration
and statistics only. No configuration changes can be made at this level.
View Node Command List
acm
alarm
alignment_sp
atpc
ber
cableloss
config
cos
datapath
datapattern
date
default_opmode
eth_info
exit
failover
fanctrl
freq
guard_time
help
httpd
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
119
Ibm
iduled
ipconfig
license
link_history
linktest
loglevel
loopback
model
mse
oduled
odupower
odurxagc
opmode
power
remark
rps
rssi
show
siglevel
snmpd
speed
status
Sync_status
sysinfo
syslog
targetrssi
tdm
telnetd
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
120
temp
tftpd
threshold
trap
uptime
Utype
version
voltage
ConfigNode
Userscanenterthisnodebytypinginthecommandconfigfromtheviewnode.They
willbepromptedforapasswordandaftersuccessfulauthenticationusersentersthe
configmode.Allconfigurationsettingscanbechangedhere.
Allthecommandsenteredwithoutanyparametersreturnsthecurrent
configuredvaluesandaresimilartoviewnode.
Allconfigurationchangesareappliedimmediatelyanddontrequireanyreboot
(exceptspeedinwhichthesettingsareappliedimmediately,butitdoes
requirerebootaftersave).
Allconfigurationchangeshavetobesavedinordertobepersistentacross
reboot.Asinglesavecommandwillsaveallconfigurationchanges
Userscangobacktotheviewnodebytypinginthecommandexit
CLI
Ranges
Default Value
acm
on/off
Off
alarm
on/off
Off
alignment_mode
on/off
Off
atpc
on/off
Off
ber
0E00 to 2E-03
N/A
bootimage
N/A
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
121
cableloss
0,0,0
config
export, import,remove,view
N/A
cos
Priority 0:
Priority 1:
Priority 2:
Priority 3:
Priority 4:
Priority 5:
Priority 6:
Priority 7:
COS Queue = 0
COS Queue = 1
COS Queue = 2
COS Queue = 3
COS Queue = 4
COS Queue = 5
COS Queue = 6
COS Queue = 7
datapath
<0-2>
datapattern
<fpga | modem>
fpga
date
<0-99><1-12><1-31><0-23><0-60>
debug
N/A
N/A
default_opmode
<on/off>
Off
diagnostic
N/A
N/A
eth_info
<1-6>
N/A
exit
N/A
N/A
failover
On/off
off
fanctrl
<0-2>
freq
freq_duplex
ODU dependent
N/A
ftp
N/A
N/A
get
N/A
N/A
guard_time
10-30 seconds
15 seconds
help / ?
N/A
N/A
httpd
<on/off>
On
ibm
off
iduled
TDM/RSSI
RSSI
ipconfig
<ip address><netmask><gateway>
ip
192.168.100.100
netmask:
255.255.255.0
gateway:
192.168.100.100
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
122
N/A
None
N/A
license_speed
<1-2> Key
N/A
license_tdm
Key
N/A
N/A
N/A
linktest
duration <1-99>
loglevel
0,1
loopback
Off
model
N/A
mse
duration <1-99>
oduled
<on/off>
On
odupower
<on/off>
Off
odurxagc
<on/off>
Off
opmode
<on/off>
Off
passwd
trango
link_history
power
0-30
10dBm
prompt
Character string
N/A
reboot
N/A
N/A
port
TrangoLink GigaPLUS
remark
<string 1-100bytes>
reset
N/A
N/A
rps
on/off
off
rssi
Duration <1-99>
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
123
user)
CLI View Node:
trango
trango
public
private
Web Interface:
trango
trapstr
show
<passwords>
snmp trap:
siglevel
N/A
N/A
snmpd
On
speed
<channel_bw> <modulation>
<0> <qam16>
channel_bw
4/7/10/14/20/28/30/40/50/55/56/80
modulation
qam16
N/A
sync
N/A
N/A
sync_status
N/A
N/A
sysinfo
<0-6>
syslog
<clear>
N/A
targetrssi
<-88 - -25)
tdm
<coding. <mode>
AMI T1
telnetd
on/off
on
temp
N/A
N/A
tftpd
on/off
Off
status
-40
trap
0.0.0.0
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
124
<0 5>
N/A
ip
N/A
cr
N/A
N/A
uptime
N/A
N/A
utype
N/A
Main
utype_switch
N/A
N/A
version
N/A
N/A
voltage
N/A
N/A
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
125
DebugNode
Thisnodeisadditionalmanagementportrelatedsettingsandusersenterthedebug
node,bytypinginthedebugcommandfromtheconfignode.Userscanreenterthe
viewnodebyenteringtheclicommandfromwithinthedebugnode.
DebugNodeCommandList
cli
N/A
UsedtoEntertheCLI(trangoview)node
help
N/A
Displaylistofcommandsinthedebugnode
ping
<ipaddress>
pingnetworkhosts
route
N/A
Displaythecurrentsystemroutingtable
ssh
<ipaddress>
sshintoanotherhost
syslog
N/A
printsystemlog
telnet
<ipaddress>
telnetintoanotherhost
tg_reboot
N/A
Rebootradio
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
126
IndividualCommandDetails
acm
SYNTAX
acm
acmenable<on|off>
acmmod<modulation>mse_im<400>
acmmod<modulation>mse_de<400>
profile
QPSK
16QAM
32QAM
64QAM
128QAM
256QAM
mse_im
20.3
25.3
26.3
29.2
32.1
NA
mse_de
NA
18.5
21.3
24.3
27.2
27.2
enable
enabled
enabled
enabled
enabled
enabled
enabled
ConfigurationStorage:Yes
acmwithoutanyparameterwilldisplaythecurrentstatusofACM
thresholdvalueandenableoptions.
DESCRIPTION
acmisusedtodisplayACMfeaturesparametersincludingACMenable,and
MSEvaluesintheimprove/degradethresholdtables.
acmenableisusedtoturnontheadaptivecodingandmodulationfeature.
Whenenabled,thecurrentRXmodulationmayshifttodifferentprofile
basedonthecurrentMSEvalueandasetofpredefinedMSEdegradeand
improvethresholds.Thespeedcommandneedstobeissuedafteracm
enableon/offcommand.
ACMisnotsymmetricandeachend(TxRx)mayhavedifferentprofilesata
giventimedependingupontheMSEvaluesoneachend.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
127
acmmodeisusedtoupdateMSEvaluefordegradeorimprovethreshold
table.Thenewthresholdvaluesshouldbeeffectimmediatelyupon
execution.
Certainprofilesarenotavailablewheninitialspeedmodulationisat
QAM256.Belowistheavailableprofiles:
profile
QPSK
16QAM
64QAM
256QAM
mse_im
20.3
25.3
29.2
32.1
mse_de
17.10
18.5
24.3
27.2
enable
enabled
enabled
enabled
enabled
Note:Enable/disablecertainprofilefunctionalityisnotsupportedinthis
release.
alarm
SYNTAX
alarm
alarm<alarm1|alarm2><on/off>
Default:alarm1OFF,alarm2OFF
ConfigurationStorage:No
alarmwithoutanyparameterwilldisplaythecurrentstatusforbothalarm1
andalarm2
alarmisasystemlevelcommand.
DESCRIPTION
Usermayspecifyalarm1oralarm2astheactioninthethresholdsettings.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
128
Thiscommandisusedtoturnoffthealarmafterthealarmhasbeen
triggered,orturnonanalarmremotely.
Alarmsarealsosetbythesysteminternallywhencertainconfigured
thresholdsareexceedingitsexpectedrange.
atpc
SYNTAX
atpc
atpcenable<on|off>
atpcmax_power<030>
atpcstep_size<05>
Default:enableOFF,maxpower17dBm,stepsize1
ConfigurationStorage:Yes
atpcwithoutanyparameterwilldisplaythecurrentstatusofATPCfeature
DESCRIPTION
atpcisusedtodisplayATPCfeaturesparametersincludingATPCstepsize,
ATPCenable,andATPCmaxpower.
atpcenable:ATPCisusedtoautomaticallyadjusttheremoteendODU
transmitpowerinordertomaintainthedesiredlevelofRSSI(within2dB
rangeoftargetrssi)atthelocalend.Thisfeaturewillworkonlywhenboth
localandremoteradioareenabled.
atpcmax_power:SetthemaximumATPCpower.Thisparameterisused
onlywhentheATPCisenabled.
UsercannotexecutethepowercommandwhenATPCisturnedon.The
systemwilladjustthepowerautomaticallybasedonthemax_powerand
step_size.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
129
atpcstep_size:SpecifiedthestepsizeforeachoftheATPCcommandfor
powerup/down
Bydefault,foreachoftheatpcpowerup/downcommandfromthe
remoteunit,therewillbe1dBincrement/decrement.Theusermay
specifythisstepsizetomaximumof5dBpercommand.Thepower
commandtoODUis1dBatatime,butwillgouptonumberofstepsize
perATPCcommand.
Theuserisresponsibleformeetinglegal/regulatoryrequirementsforTx
power.
EXAMPLE
(CLIview)atpc
ber
SYNTAX
ber
ber<099durationinseconds>
Default:1second
ConfigurationStorage:Yes
berwithoutanyparameterwilldisplaythecurrentBER,LOCK,MSE,RSSI
values
DESCRIPTION
BERappliestoEthernetDataonly,andisbasedonCRC.FCserrors,and
onlyisfunctionalwhenthedatapatternissettointernalmode.Itwill
alwaysbezeroonlivetraffic.
bootimage
SYNTAX
TrangoSystems,Inc.
bootimagetoggle
GigaPlusUserManualRev1.3
130
bootimageupgrade<idu|odu>
Default:N/A
ConfigurationStorage:NO
bootimageisasystemlevelcommand.
DESCRIPTION
bootimagetoggle:Toswitchcurrentimagesbacktothepreviousupdated
imageinasetofFPGA1,FPGA2,OS,FW.PICandODUfirmwarearenot
allowedtobetogglebackunlessperformingbootimageupgradeagain.
bootimageupgrade:upgradetherequiredsoftwareimagesontheradio,
aftertheimageistransferredontheradioviatftp.
<idu>optionwillupgradealltheIDUfirmwareinsequenceofFPGA,OS,
FW,PICfromONEtarfileunder/tmp/idu_GigaPlus_vX.X.tarrebootis
requiredaftertheiduupgrades.
<odu>optionwillupgradeODUfirmwarewiththefileunder
/tmp/odu_fw.binor/tmp/rem_fw.bin(nameisnotexchangeable)
cableloss
SYNTAX
cableloss
cableloss<loss140><loss315><loss915>
Default:0forallthreechannels
ConfigurationStorage:Yes
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
131
cablelosswithoutanyparameterwilldisplaythecurrentcablelossvalues
fortheIFcablegoingtotheODU
Validrangeofoperation:
loss140:range015,loss315:range026,loss915:range050
DESCRIPTION
ThiscommandisonlyapplicableforSPODUs
cablelosscommandisusedtosettheappropriatecablelossforthe3
frequenciesbasedonthelengthoftheIFcoaxialcableusedtoconnectthe
IDUandODU.
cablelossinfomustbesenttotheODUsothatitcanmaintaintheoutput
Tx/Rxpowerlevelsaccurately.ThisonlyappliestoSPODUs.Forsystems
withHPODUsnocablelosssettingisrequired.Thecableloss
compensationisbuiltinintotheHPODU.
config
SYNTAX
configexport
configimport
configremove
configsave
configview
Default:N/A
ConfigurationStorage:No
configisasystemlevelcommand.
DESCRIPTION
TrangoSystems,Inc.
configexport::TheoptionallowstheusertocreateaASCIIfile(config.txt)
GigaPlusUserManualRev1.3
132
ofthecurrentsystemconfiguration,whichcanthenbetftpfromthePC,
whichtheusercanedit/printorimporttoothersystem
configimport:Thisoptionallowstheusertopushaconfigurationfile
(shouldbeintheformatascreatedbyexport)intothesystemthroughtftp
andthenissuetheconfigimportcommandtoapplythesettingsfrom
theconfig.txtfiletothesystem.
configremove:Thisoptionallowsremovingthecurrentsystem
configurationfileconfig.binandallsettingswillberesettofactory
defaults.Thisisdifferentthantheresetconfigwhereallthepassword
settingsarealsobeingreset.
configsave:Savecommandisusedtosavethecurrentsystem
configurationtotheflash,sothatsystemsettingsarepersistentacross
reboot/powercycles.
Savecommandshouldbeusedaftersystemsettingchange.Otherwiseit
willbelostafterreboot.Multiplechangescanbesavedbyonesave
command.
configview:TheoptiondisplaysthecurrentsystemconfigurationinASCII
formatontheconsole.Thesavedconfigisdisplayed.
cos
SYNTAX
cos
cos<priority><queue>
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
133
Default:
Priority0
Priority1
Priority2
Priority3
Priority4
Priority5
Priority6
Priority7
COSQueue=0
COSQueue=1
COSQueue=2
COSQueue=3
COSQueue=4
COSQueue=5
COSQueue=6
COSQueue=7
ConfigurationStorage:YES
cosisasystemlevelcommand.
DESCRIPTION
Thiscommandisusedtomapthepriorityoftheincomingpackettooneof
the8COSqueuesbasedonthepacketpriorityper802.1p.Thetrafficclass
oftheincomingpacketismapped1to1tothe8priorities.
Theschedulingisstrictprioritywith
COSQ7>COSQ6>COSQ5>COSQ4>COSQ3>COSQ2>COSQ1>COSQ0
EXAMPLE:
(CLIconfig)#cos23
COSmappriority=2,queue=3
SUCCESS
(CLIconfig)#cos
COSscheduling:strict
Priority0:COSQueue=0
Priority1:COSQueue=1
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
134
Priority2:COSQueue=3
Priority3:COSQueue=3
Priority4:COSQueue=4
Priority5:COSQueue=5
Priority6:COSQueue=6
Priority7:COSQueue=7
datapath
SYNTAX
datapath<02>
0:ETHonly
1:ETH+T1
2:ETH+E1
DEFAULTVALUE
0:EthOnly
DESCRIPTION
Selecttheprofiletobeusedonthedatapathoftheradio.
ALicensekeyisrequiredforTDM(T1/E1)mode.
Bandwidthfor8T1or8E1circuitsalwaysreservedonceselected,
regardlessofwhetherdataisbeingsentornot.Thiswillreducethe
Ethernetcapacityaccordingly
RefertoAppendixAforvalidprofilesapplicabletospecificdatapath
mode
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
135
RELATED
Speed,license
datapattern
SYNTAX
datapattern<external|internal>
Default:externaldatapattern
ConfigurationStorage:Yes
datapatternwithoutanyparameterwilldisplaythecurrentstatus
DESCRIPTION
Setsdatasourceforthemodem.datapatterncanbegeneratedfromeither
fpga(external)orthemodem(internal),usedtogeneratePRBSdata
Thedatapatternshouldbesettofgpaduringnormalmodeofoperation,
otherwisenouserdatafromGigEortheT1portswillbetransmitted.
date
SYNTAX
date<year><month><day><hour><minute>
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
136
Default:N/A
ConfigurationStorage:No
datewithoutanyparameterwilldisplaythecurrenttimeofdate.
dateisasystemlevelcommand.
DESCRIPTION
Allowtheusertosetandreadthecurrenttimeanddate
debug
SYNTAX
debug
Default:N/A
ConfigurationStorage:No
debugisasystemlevelcommand.
DESCRIPTION
Exitcurrentnodeandenterthedebugmode.
EXAMPLE
Toenterdebugmode
(trangoconfig)#debug
debug>
RELATED
TrangoSystems,Inc.
cli
GigaPlusUserManualRev1.3
137
defaultopmode
SYNTAX
default_opmode
defaultopmode[on|off]
Default:defaultoperationmodeOFF
ConfigurationStorage:Yes
default_opmodewithoutanyparameterwilldisplaythedefault
operationalmode
DESCRIPTION
Setthedefaultopmodetouserspecifiedinput.
IfON,thesystemtopoweronwithreadytobeoperational
ifOFF,theuserhastoexplicitlyturnonopmode.
Opmodesettingsaredependentupondefault_opmodeafterpowerup
diagnostics
SYNTAX
diagnostic
Default:N/A
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
138
ConfigurationStorage:No
diagnosticisasystemlevelcommand.
DESCRIPTION
Diagnosticcommandistocommunicatewithallsystemdevicesandgeta
currentsnapshotofthesystemstatus.Thisismainlyusedfordebugging
purposes.
eth_info
SYNTAX
eth_info
eth_info<14><14><14><14>
Default:N/A
ConfigurationStorage:No
eth_infowithoutanyparameterwilldisplayconfigurationforall4ports.
eth_infoisasystemlevelcommand.
DESCRIPTION
DisplayEthernetportconfigurationsinclude:enable,status,pauseframe,
autonegotiation,duplex,priority,speedandmaxrate.
Userhavetheoptionstodisplayoneormoreportconfigurationforupto4
portsfordisplay
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
139
exit
SYNTAX
exit
Default:N/A
ConfigurationStorage:No
exitisasystemlevelcommand.
DESCRIPTION
Exitcommandisusedtologoutfromthecurrentnodetothelower
node.Typingexitfromthedebug>nodewillbringusertothelogin
prompt.
EXAMPLE
ToSwitchtoviewnodefromtrangoconfignode
(trangoconfig)#exit
(trangoview)
Tologoutfromthesystem
debug>exit
RELATED
cli,config
failover
SYNTAX
TrangoSystems,Inc.
failover
GigaPlusUserManualRev1.3
140
failover<0:off,1:OnwithportOFF,2:OnwithportON>
Default:OFF
ConfigurationStorage:Yes
failoverwithoutanyparameterwilldisplaythecurrentstatusfor
thefailovermode
DESCRIPTION
Displayandconfigurethefailovermodefeature.Failovercableis
requiredbetweentwoIDUforthisfeaturetoworkproperly.
OptionOFF:Disablefailovermodefeature.
OptionONwithportOFF:StandbyunitdisableallEthernet/TDM
ports.
OptionONwithportON:StandbyunitwillleavetheEthernet/
TDMportenabled.
Whenenabled,aKeepAlivemessagewillbeexchangedbetween
thetwoGigaPlusIDUtodeterminetheirutype.
NOTE:Thiscommandwillsettheutypestatetodefaultand
performelectionperiodwhichwillaffecttheradiolink.Therefore,
itisnotrecommendedtobeexecutedwhilethelinkisrunningwith
traffic.
EXAMPLE
(CLIconfig)#failover
Failovermode:off
(CLIconfig)#failoveron
Failovermode:on
SUCCESS
RELATED
cli,config
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
141
fanctrl
SYNTAX
fanctrl
fanctrl<on|off>
Default:fanON
ConfigurationStorage:Yes
fanctrlwithoutanyparameterwilldisplaythecurrentstatusforthefan.
fanctrlisasystemlevelcommand.
DESCRIPTION
Displayofthestatusofthecoolingfaninthechassisandallowittobe
turnedonandoff.Itisnotrecommendedtoturnthefanoffiftheambient
temperaturesurroundingtheIDUwillexceed10degC.
freq
SYNTAX
freq[tx_freqinMHz]
Default:nodefaultfrequency.0
ConfigurationStorage:Yes
Thesettingoffrequencycanbetothe250kHzresolution.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
142
EXAMPLE:freq17727.5
freqwithoutanyparameterwilldisplaythecurrentTxandRxfrequencyfor
theODU.
DESCRIPTION
Setsthetransmitfrequencyandthereforethereceivefrequency.Only
certainTxRxfrequencypairsarevalidforeachmodeloftheradio.
CertainIDU/ODUPLLsynthesizersareprogrammedforeachandevery
individualfrequency.
GigaPlussupportsmodel6,6E,11,11E,15,18,18E,23,23EofSPODUs
And638GhzHPODUs
freq_duplex
SYNTAX
freq_duplex[duplex]
Default:0
ConfigurationStorage:Yes
freq_duplexwithoutanyparameterwilldisplaythecurrentduplexvalue
ONLYforHPODUs
DESCRIPTION
Setstheduplexvaluetobeusedforprogrammingthetransmitfrequency
andthereforethereceivefrequency.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
143
ftp
SYNTAX
ftp
ftp<server_ip><user_name>
ftp>get<file_name>:performftpgetcommand.Getfilefromtheftp
server
ftp>mode:configureftpoperationmode.Passiveoractive.
ftp>put<file_name><serverpath>:performftpputcommand.Putfileto
theftpserver
ftp>logout:logoutofftpsession.
Default:server_ip=NULL,user_name=NULL,mode=Passive
ConfigurationStorage:No
DESCRIPTION
Toperformftpoperation.ProvidethecommandwiththeftpserverIPand
theuserlogin.Enterthepasswordwhenprompted.
ftp>get<file_name>:DoNOTsupplythepathtothefilethatneedstobe
putontothe.Itwillbestoredinthedefaultsystemdirectory
Seeexamplebelow.
ftp>put<sourcefile><destination>:sourcewillbethefilenameonly,.
Destinationwillincludebothpathandfilename.
Note:fileontheftpservermightneedtobedeletedbeforeitcanbedown
withthesamefilename.
ftp>mode<mode>:DefaultoperationmodeisPassiveandcanbe
configureasactivewiththemodeoption.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
144
ftp>logout:logoutoftheftpsession.
Note:PleaseensurethattheFTPserverisreachablebycheckingwithping
commandfromdebugprompt.
.
EXAMPLE
(CLIeng)#ftp10.14.0.85trango
Password:
ftp>getzImage
#######################################################
Getoperationsuccessfulwithpassivemode
ftp>putlinkloss.txtlinkloss.txt
#######################################################
Putoperationsuccessfulwithpassivemode
ftp>logout
(CLIconfig)#
help/?
SYNTAX
Default:N/A
ConfigurationStorage:No
?isasystemlevelcommand.
DESCRIPTION
TrangoSystems,Inc.
Typingthe?commandwilldisplaythelistofcommandsinthecurrent
GigaPlusUserManualRev1.3
145
nodewithaonelinedescriptionofthecommands
EXAMPLE
(trangoconfig)#?
<DisplaytheListofcmds>
RELATED
N/A
guard_time
SYNTAX
guard_time
guard_time<1030>seconds
Default:15seconds.
ConfigurationStorage:Yes
guard_timewithoutanyparameterwilldisplaythecurrentguardtime
valueinseconds.
DESCRIPTION
Guardtimeisonlyvalidwithfailoverfeatureenabled.Whenevera
switchoverhasoccurred,theguardtimewillbestartedandwithinthe
guardtimeperiod,noadditionalswitchoverisallowed.
httpd
SYNTAX
TrangoSystems,Inc.
httpd
GigaPlusUserManualRev1.3
146
httpd<on|off>
Default:httpdON.
ConfigurationStorage:Yes
httpdwithoutanyparameterwilldisplaythecurrentstatusfortheweb
interfacedaemon
httpdisasystemlevelcommand.
DESCRIPTION
Turnonhttpdserverforwebinterfaceaccess.
Thewebinterfacesupportsbothsecure(https)andnormal(http)access.
ibm
SYNTAX
ibm
ibmenable<on|off>
ibmip<ip_addr><netmask>
ibmport<14:ge1ge4>
ibmvlanid<14088>
Default:enable=OFF,ip=172.16.10.0,netmask=255.255.0.0,vlanid=100.
ConfigurationStorage:Yes
IbmwithoutanyparameterwilldisplaythecurrentIBMfeatures
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
147
parameters.
DESCRIPTION
IbmisusedtoconfiguretheInBandManagement(IBM)channelto
managethesystem.
BothIBMandtheOutofBandManagement(OBM)canbeusedtogether.
ThemanagementVLANIDcanbeconfiguredbasedontheuser
requirementfrom14090.TheIPaddressfortheIBMchannelis
independentoftheOBMportontheIDU.The2IPaddressesneedtobe
unique.
ipconfig
SYNTAX
ipconfig
ipconfigip[ip_addr][netmask]
ipconfiggateway[default_gateway_ip]
Default:IP=192.168.100.100,NETMASK=255.255.255.0,
GATEWAY=192.168.100.100,REMOTE_IP=0.0.0.0
ConfigurationStorage:Yes
ipconfigwithoutanyparameterwilldisplaythecurrentIPconfiguration
andremoteIPaddress.
ipconfigisasystemlevelcommand.
DESCRIPTION
ThiscommandisusedtosetIPaddress,subnetmaskanddefaultgateway
forthemanagementportofthesystem.ThesystemMACaddresscanbe
displayedviathiscommand.Thechangetakesplaceeffectimmediately.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
148
Ipconfigip:BothIPandnetmaskparametersmustbepresent.
Ipconfiggateway:ConfigurethedefaultgatewayIP.ValidforbothInband
andOutofbandport.
license
SYNTAX
licenseDisplaylicenseenablestatus
license_speed<12><speedkey>
license_tdm<tdm_key>
Default:N/A
ConfigurationStorage:No
DESCRIPTION
Licensekeycommandisusedtosetthelicenserequiredforusinghigher
speed(>100Mbps)ontheradio.Speedkey1enablesspeedupto
200Mbpsandspeedkey2enablesMaxspeed.Pleaserefertotheactual
speed/modulation/channelwidthcombinationforvalidprofiles.
Thelicensekeyisspecifictoeachunit(managementportEthernetMAC
address)andisnottransferable.ThePDHkeyenablesallT1/E1portson
theIDU.
Pleaserefertovalidspeedprofiles.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
149
link_history
SYNTAX
link_history
Default:N/A
ConfigurationStorage:No
DESCRIPTION
Thiscommandistodisplayifthelinkhistoryandthelinksteadyflag.
Linkhistory:containsthenumberoflinkup/downoccurredsincethe
systembootupandthisnumberdoesnotgetresetuntiltheradioreboots.
Linksteady:currentstatusoflinksteadyflag.Definedtobe
approximately40secondsafterthelinkhasbeenestablished.
linktest
SYNTAX
linktest<iterations>
Iterationrangefrom199seconds
Default:defaultiteration=1second
ConfigurationStorage:NO
msewithoutanyparameterwilldisplaythecurrentmsevalueforboth
Modem1andModem2
DESCRIPTION
TrangoSystems,Inc.
Linktestcommandisusedtotestthecurrentlinkstatusandcanbeused
tomonitorthelink,basedonthespecifiedduration.CLIpromptwillnotbe
GigaPlusUserManualRev1.3
150
accessiblewhilelinktestisrunning
Thelinktestshowsthefollowingintheoutput
Lock:RadioLockStatus
1:ifallmodemlocksarelocked
0:ifanylockindicatorshowsunlocked
RSSI:ThecurrentRSSIvalue
MSE:ThecurrentMSEvalue
BER:TheinstantaneousBERvalue(1secinterval)
loglevel
SYNTAX
loglevel[02]
<0:Setting,1:Event,2:Status>Default:2
ConfigurationStorage:Yes
DESCRIPTION
loglevelisusedtosettheappropriateloggingforthesystem.
Thiscommandisusedtosetrequiredloglevelsforsystemlogging.Thelog
levelneedstobesetforeachactivitytobemonitored.Oncetheloglevels
areset,thelogscanbemonitoredthroughthesyslogcommand
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
151
loopback
SYNTAX
loopback
loopback<off|if|dig|rfl_gen|rf_refl|baseband>
Default:OFF
ConfigurationStorage:Yes
loopbackwithoutanyparameterwilldisplaythecurrentstatus
DESCRIPTION
Activatesoneoftheloopbackmodesfortestpurposes.Mustbeturnedoff
byacommand.TheCLIisstillactivewhilethemodeisontoallow
monitoringofvariousparameters.
DuringIFanddigitalloopback,thetransmittersignalfromthefarendwill
stillbepresentattheinputtotheIDUandmaycauseapoorresult.
Therefore,theodupowerOFFontheremoteendofmayberequiredto
eliminateanysignalfromthefarendwhichmaycorrupttheresult.
Allloopbackmodeswillstoplivetrafficfrompassingacrossthelink
model
SYNTAX
model
Default:N/A
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
152
ConfigurationStorage:No
DESCRIPTION
DisplaycurrentODU/IDUmodelandserialID.
Thefollowinginformationarebeendisplayed:ODUmodel,IDUmodel,
ODUSerialID,IFRev,IFSerial,IDUModel,IDUSerialIDforeachradio
mse
SYNTAX
Mse
mse<duration>:durationrangefrom199seconds
Default:defaultduration=1second
ConfigurationStorage:NO
msewithoutanyparameterwilldisplaythecurrentmsevalueforthe
receivedsignal.
DESCRIPTION
msecommandisusedtomonitortheMeanSquareError(MSE)ofthelink
receivedsignalbasedonthespecifiedduration.CLIpromptwillnotbe
accessiblewhilelinktestisrunning.
oduled
SYNTAX
TrangoSystems,Inc.
oduled
GigaPlusUserManualRev1.3
153
oduled<on|off>
Default:ON
ConfigurationStorage:YES
oduledwithoutanyparameterwilldisplaythecurrentstatusofODULED
display
DESCRIPTION
TurnON/OFFODUledfordisplayRSSIvalue.AppliesonlytoSPODUs
odupower
SYNTAX
odupower
odupower<on|off>
Default:OFF
ConfigurationStorage:Yes
odupowerwithoutanyparameterwilldisplaythecurrentstatusofODU
power.
DESCRIPTION
ThecommandisusedtoTurnON/OFFodupower.
TheODUispoweredfromtheIDUovertheIFcablewith48VDC
ItisrecommendedtoturnofftheODUpowerduringinitialinstallingofthe
ODUonthetowerandothermaintenance
TheresponsetimeforODUpowerONwillvarydependingupontheODU
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
154
model.ItislongerforHPODUs
odurxagc
SYNTAX
odurxagc<on|off>
DEFAULTVALUE
Off
DESCRIPTION
Thecommandisusedtosettheodurxgaincontrolloopinthesystem.This
controlsthereceivelevelintotheIDUfromtheODUandkeepsthe
receivedlevelwithinapredefinedrange.ThishelpstoimproveMSEand
maintainbettersystemperformanceinfadingconditions.
ApplicableonlyforSPODU[6,11,11E,18,18EModel]
EXAMPLE
ToturnON/OFFodurxagcloop
(trangoconfig)#odurxagcon
ODURxAGC:on
SUCCESS
Toviewcurrentodurxagcstatus:
(trangoconfig)#odurxagc
ODURxAGC:off
RELATED
targetrssi,cableloss
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
155
opmode
SYNTAX
opmode
opmode<on|off>
Default:OFF
ConfigurationStorage:NO
opmodewithoutanyparameterwilldisplaythecurrentstatusofODU
operationmode
DESCRIPTION
OpmodecommandisusedtoenablethetransmitterontheODU.
Opmodesettingsarenotpersistentacrossreboot.Seedefault_opmode
command
freqandspeedsettingsarerequiredtobesettovalidvaluebefore
opmodecanbeturnedON.
passwd
SYNTAX
Passwd<new_password><confirm_password>
Default:N/A.Defaultconfignodepasswdistrango
ConfigurationStorage:Yes
passwdisasystemlevelcommand.
<new_password>mustbeatleast4charactersandnomorethan10
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
156
characters
<new_password>and<confirm_password>mustbeidenticalforthenew
passwordtotakeeffect
DESCRIPTION
Updatethecurrentpasswordforenteringconfignode.Thenew
paswordtakeseffectonlyafterarebootcommandorreentertheview
nodefromdebugpromptwithcli command.
port
SYNTAX
porteth<16>auto_negotiate<on|off>
porteth<16>duplex<half|full>
porteth<16>enable<on|off>
porteth<16>maxrate<01000>
porteth<16>pause<on|off>
porteth<16>priority<07>
porteth<16>speed<01000>
DESCRIPTION
ThiscommandisusedtosetEthernetportsettings.Ethernet:auto
negotiation,enable/disable,speed,priority,pauseframe,duplexandmax
rate.
Speed/Duplex/AutoNegotiateisfixedforge3/ge4whichareGigEFiber
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
157
portsandthesesettingarenotconfigurable
power
SYNTAX
power
power<030>
Default:10dBm
ConfigurationStorage:Yes
opmodewithoutanyparameterwilldisplaythecurrentstatusofODU
transmitpowerlevel
DESCRIPTION
PowercommandisusedtosettheODUtransmitpowerlevel.The
maximumlevelisdependentuponthemodulationandODUmodel.
Ensurethatthepowerdoesnotexceedtheratingforthemodulationbeing
usedorsignaldistortionwilloccur.SPODUlevelsareshownherefor
refrence.
SPODUModel
18,18E
6,6E,11,11E
TrangoSystems,Inc.
Modulation
QAM256
QAM128
QAM64
QAM256
QAM128
QAM64
QAM32
GigaPlusUserManualRev1.3
MaxTxpower
17
18
19
19
20
21
22
158
23,23E
15E
QAM256
QAM16
QPSK
QPSK
QAM16
QAM64
QAM128
17
19
20
23
22
21
20
TheusercannotchangepowerwhenATPCisON.
prompt
SYNTAX
promt<prompt_str>
Default:CLI
ConfigurationStorage:Yes
promptisasystemlevelcommand.
DESCRIPTION
TrangoSystems,Inc.
PromptcommandisusedtoupdatetheCLIpromptwithmoredescriptive
nameofthesystem.Defaultpromptsare<CLIview>,<CLIconfig>.The
usermayupdatetoastringthatismoremeaningful.
GigaPlusUserManualRev1.3
159
reboot
SYNTAX
reboot
Default:N/A
ConfigurationStorage:No
rebootisasystemlevelcommand.
DESCRIPTION
Rebootsentiresystemincludingdatapath.Noconfigurationchangesafter
thesystemreboot.
remark
SYNTAX
remark
remark[system_remark]
Default:Remark=TrangoGigPlus
ConfigurationStorage:Yes
DESCRIPTION
Remarkofthesystemtypicallyusedforidentificationpurposes.
Devicestringisusedtodisplaythedevicenameonthetopoftherowfor
allthedevicelevelparameters.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
160
reset
SYNTAX
resetconfig
resetipconfig
resetlicense_key
Default:N/A
ConfigurationStorage:No
resetisasystemlevelcommand.
DESCRIPTION
resetconfig:Restoreallfactorydefaultconfigurationsettingincluding
resettingpasswordforsystemlogin,CLIconfignode,Webinterfacelogin.
ExcludinglicensekeyandIPconfiguration.
Arebootofthesystemisrequiredforthecommandtotakeeffect.
resetipconfig:ResetonlytheIPconfigurationtodefault.
resetlicense_key:Removeupto5licensekeys.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
161
rps
SYNTAX
rps<on|off>
Default:OFF
ConfigurationStorage:Yes
rpswithoutanyparameterwilldisplaythecurrentstatusofRapidPort
Shutdownfeaturestatus.
DESCRIPTION
ThiscommandisusedtoconfigureRapidPortShutdown(RPS)
functionality.TheRPSsettingneedstobethesameonbothsideofthelink
forproperoperation.
IftheRPSisenabledthedataports(GigE)onbothsideofthelinkare
immediatelyshutdownintheeventofalinklossinordertoprovideafast
switchovermechanismtotheexternalroutersandswitches.
RELATED
Sysinfo
rssi
SYNTAX
rssi<iteration>
Iterationrangefrom199seconds
Default:defaultiteration=1second
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
162
ConfigurationStorage:NO
rssiwithoutanyparameterwilldisplaythecurrentmsevalue
DESCRIPTION
rssicommandisusedtomonitorthereceivedsignallevel.Itisusedto
monitorthelink,basedonthespecifiedduration.CLIpromptwillnotbe
accessiblewhilerssicommandisrunning.
RSSIvaluerangeshouldbebetween90and30
ForsomeSPODUs,theRSSIvaluewillnotdisplaybelow65dBm
accurately,soforantennaalignmentpurposestheMSEcanbeusedasa
guideuntilthesignalisacquired.SeetheAntennaAlignmentSectionfor
moreinformation
siglevel
SYNTAX
DESCRIPTION
siglevel
Default:N/Q
ConfigurationStorage:No
Siglevelwilldisplaythesignallevelrelatedparameterformodem1
Thiscommandisusedtoassistdebugginganysignalpathrelatedissue.
IDURSSI:idurssionthemodemlevel.
NomralizeMSE/RadialMSE:
NormMSE=RadialMSEphasenoiseresidueisminimal
NormMSE>RadialMSEthereissomeamplitudenoise(AM
distortion)
NormMSE<RadialMSEphasenoiseresidueexist,thatthePLLdid
notfullycorrect
UncorrectBlock:Errorreportedbymodemwhenpassingtraffics.
Powersensors:usedtomakesureTXpoweraccuracy.Somemodels
usesonlyIFwhileotherusingonlytheRFvalues.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
163
Oduattn:Makesuretheattenuatorsarebeensetcorrectly.
Note:Blockcounter&uncorrectblockcounterareaccumulative
valuessincethelastlinkestablishment.Theyarecollectedona20
secondperiodicbasis.
(CLIview)#siglevel
IDURSSI:0
NormalizedMSE:348
RadialMSE:340
LDPCDecoderStress:0
ExternalAGC:1604
CarrierOffset:2466
RxSymrate:49500732
BlockCounter:0
UncorrectBlock:0
LDPCAvgIteration:0
Outputcorrectedbytes:0
ReturnLoss:0x0000
TxPoweralarm:ok
TxPAalarm:ok
PAon/offalarm:on
TxPowerRangealarm:ok
TxPoweractual:20.00
RxPoweractual:23.00
Channeltest:Pass
Telemetrydebug:Fail
(CLIview)#
EXAMPLE
snmpd
SYNTAX
snmpd
snmpd<on|off>
Default:ON
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
164
ConfigurationStorage:No.AlwaysONatsystembootup.
snmpdwithoutanyparameterwilldisplaythecurrentstatusforthe
tftpddaemon
DESCRIPTION
Turnon/offsnmpdagentontheradio.Mustbeontoperformany
SNMPget/set.
EXAMPLE
Toturnsnmpdoff
(trangoconfig)#snmpdoff
snmpd:off
SUCCESS
RELATED
Ipconfig,snmptrap,trapip
speed
SYNTAX
speed<bandwidth><modulation>
<bandwidth>:4,7,10,14,20,28,30,40,50,56,80
<modulation>:qpsk,qam16,qam32,qam64,qam128,qam256
Default:bandwidth20,QAM128
ConfigurationStorage:Yes
speedwithoutanyparameterwilldisplaythecurrentspeedsetting
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
165
DESCRIPTION
LoadthecorrespondingthemodembinaryandconfigureTxandRx
bandpassfilters.
Thespeedcommandwillalsoconfigurethemodemprotectionmode
basedonthesystem_modeconfiguration.Onlywhenthe1+1HSBmodeis
set,themodemmaybeconfiguredasworkingorprotectionmode.
Binariesselectionforthespeedcommandisbasedon5different
configuration:tdm_mode,acmenable,modulationandbandwidth.
Makingchangesviathetdm_mode,oracmenablecommandswill
requireasubsequentreloadofthespeedsettingforproperoperation.
Symrate
Modulation
TXBPF
RXBPF
Speed
Symrate
Licensekey
QPSK
18.75
22
10
3.50
None
QPSK
18.75
22
10
5.6
None
10
QPSK
18.75
22
15
8.32
None
14
QPSK
18.75
22
22
12.20
None
20
QPSK
30
38
30
17.42
None
28
QPSK
30
38
46
26
None
30
QPSK
50
39
46
26
None
40
QPSK
50
66
64
35.42
None
50
QPSK
75
66
77
43
None
56
QPSK
75
66
88
49.50
None
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
166
80
QPSK
75
66
88
49.50
None
16QAM
18.75
22
10
3.0
None
16QAM
18.75
22
10
5.6
None
10
16QAM
18.75
22
30
8.32
None
14
16QAM
18.75
22
42
12.20
None
20
16QAM
30
38
63
17.42
None
28
16QAM
30
38
94
26
None
30
16QAM
50
39
94
26
None
40
16QAM
50
66
128
35.42
Key1
50
16QAM
75
66
156
43
Key1
56
16QAM
75
66
179
49.50
Key1
80
16QAM
75
66
179
49.50
Key1
32QAM
18.75
22
37
3.0
None
32QAM
18.75
22
37
5.6
None
10
32QAM
18.75
22
37
8.32
None
14
32QAM
18.75
22
52
12.20
None
20
32QAM
30
38
79
17.42
None
28
32QAM
30
38
117
26
Key1
30
32QAM
50
39
117
26
Key1
40
32QAM
50
66
159
35.42
Key1
50
32QAM
75
66
195
43
Key1
56
32QAM
75
66
227
49.50
Key2
80
32QAM
75
66
227
49.50
Key2
64QAM
18.75
22
45
3.0
None
64QAM
18.75
22
45
5.6
None
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
167
10
64QAM
18.75
22
45
8.32
None
14
64QAM
18.75
22
64
12.20
None
20
64QAM
30
38
95
17.42
None
28
64QAM
30
38
142
26
Key1
30
64QAM
50
39
142
26
Key1
40
64QAM
50
66
194
35.42
Key1
50
64QAM
75
66
236
43
Key2
56
64QAM
75
66
272
49.50
Key2
80
64QAM
75
66
272
49.50
Key2
128QAM
18.75
22
52
3.0
None
128QAM
18.75
22
52
5.6
None
10
128QAM
18.75
22
52
8.32
None
14
128QAM
18.75
22
75
12.20
None
20
128QAM
30
38
110
17.42
None
28
128QAM
30
38
165
26
Key1
30
128QAM
50
39
165
26
Key1
40
128QAM
50
66
226
35.42
Key2
50
128QAM
75
66
275
43
Key2
56
128QAM
75
66
315
49.50
Key2
80
128QAM
75
66
315
49.50
Key2
256QAM
18.75
22
60
3.0
None
256QAM
18.75
22
60
5.6
None
10
256QAM
18.75
22
60
8.32
None
14
256QAM
18.75
22
86
12.20
None
20
256QAM
30
38
126
17.42
Key1
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
168
28
256QAM
30
38
188
26
Key1
30
256QAM
50
39
188
26
Key1
40
256QAM
50
66
258
35.42
Key2
50
256QAM
75
66
314
43
Key2
56
256QAM
75
66
366
49.50
Key2
80
256QAM
75
66
375
49.50
Key2
status
SYNTAX
statusmodem
statuspll
statusport
statustdm
statusclear
Default:N/A
ConfigurationStorage:No
statusisasystemlevelcommand.
DESCRIPTION
Statusmodem:displaymodemlinkstatus.MSE,RSSI,BER,FER
Statuspll:displayODU/IDUplllockstatus.
Statusport:displayEthernetcountersforeachports,RFcounters
andportutilizations.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
169
statustdm:displayT1/E1countersanderrorstatus
statusclear:clearallEthernet,RF,TDMcountersandport
utilization.
sync
sync
Default:N/A
ConfigurationStorage:N/A
syncwithoutanyparameterwillperformsynchronizationprocedure
betweenActiveandStandbyunit
synccommandonlyallowedtobeinitiatedonActiveunit.
SYNTAX
DESCRIPTION
syncisusedtoperformsynchronizationproceduretosyncup
configurationparametersbetweenActiveandStandbyunits.There
aresomeparameterswhichareindependentofutypeandtherefore,
willnotbesynchronizedwiththiscommand.Thefollowing
commandsaretheonesthat,ifexecuted,preventachievingsync
withtheStandbyunit:
Alarm,alignment,cableloss,fanctrl,ibm,ipconfig,licensekey,
loopbackmode,opmode,tftpdandtraps.
sync_state
SYNTAX
TrangoSystems,Inc.
sync_state
GigaPlusUserManualRev1.3
170
Default:N/A
ConfigurationStorage:N/A
sync_statewithoutanyparameterwilldisplaysynchronizationstatus
DESCRIPTION
sync_stateisusedtodisplaythecurrentsynchronizationstatus
betweenActiveandStandbyunit.
Thefollowingparameterswillnotbesynchronized.
Alarm,alignment,cableloss,fanctrl,ibm,ipconfig,licensekey,
loopbackmode,opmode,tftpdandtraps
sysinfo
SYNTAX
sysinfo
sysinfo<06>
Default:N/A
ConfigurationStorage:No
sysinfowithoutanyparameterwilldisplaythecurrentIDUandODU
configurationparameters.
sysinfotakesaparameterforinformationcategory:0=versioninfo,
1=Management,2=RadioConfig,3=SystemConfig,4=Ethernet
5=ACM,6=thresholdsettings
sysinfoisasystemlevelcommand.
DESCRIPTION
TrangoSystems,Inc.
ViewthecurrentconfigurationstatusofthelocalsideIDUandODU.
Toselectasubsetoftheentiresysteminfo,addtheargument0
through6afterthesysinfocommand
GigaPlusUserManualRev1.3
171
syslog
SYNTAX
syslog
syslog[02]
syslogclear
syslogexport
Default:0:SET,1:EVENT
ConfigurationStorage:Yes
syslogwithoutanyparameterwilldisplayallthesystemlogmessage
forupto3000lines.
syslogtakesaparameterforloglevel:0=SET,1=EVENT,2=STAT
syslogexport,exportthesyslogtoasyslog.txtfilewhichcanbetftp
bycustomer.
syslogisasystemlevelcommand.
DESCRIPTION
syslog:willdisplayallthesystemlogentriesthathavebeen
recordedsincethebootup.
syslogclear:Clearallsyslog.Only3000logentrieswillbecaptured
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
172
andwillwraparoundwhenoverflows.
targetrssi
SYNTAX
targetrssi
targetrssi<3080>
Default:40
ConfigurationStorage:YES
targetrssiwithoutanyparameterwilldisplaythetargetrssiofthe
ODU
DESCRIPTION
ConfigurethetargetRSSIlevelthattheATPCandODUgaincontrol
willtrytomaintain.Thenumbershouldbe23dBbelowthe
expectedRSSIbasedonpathcalculations.
tdm
SYNTAX
tdm
Default:N/A
ConfigurationStorage:No
DESCRIPTION
DisplayTDMportmodeandcoding
ForE1:HDB3
ForT1:AMIorB8ZS
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
173
EXAMPLE
(CLIconfig)#tdm
TDMMode:ETHonly
TDMCoding:HDB3
telnetd
SYNTAX
telnetd
telnetd<on|off>
Default:telnetdOFF.
ConfigurationStorage:Yes
telnetdwithoutanyparameterwilldisplaythecurrentstatusforthe
telnetddaemon
telnetdisasystemlevelcommand.
DESCRIPTION
Linuxsystemcommandtostartthetelnetddaemon
temp
SYNTAX
temp
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
174
Default:N/A
ConfigurationStorage:No
tempwithoutanyparameterwilldisplaythecurrentIDUandODU
temperatures.
tempisasystemlevelcommand.
Displayofthisstatusisthroughsharedmemory.
DESCRIPTION
ViewthecurrenttemperaturesofIDUandODU.Thetemperature
reportedisthetemperatureinsidetheunitindegreesCelcius
tftpd
SYNTAX
tftpd
tftpd<on|off>
Default:tftpdOFF.
ConfigurationStorage:Yes
tftpdwithoutanyparameterwilldisplaythecurrentstatusforthe
tftpddaemon
tftpdisasystemlevelcommand.
DESCRIPTION
Turnonthetftpserver.Usedtotransferdiagnosticfile,configuration
fileandsoftwareimagesduringupgrades.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
175
threshold
SYNTAX
threshold
Defaults:seethetablebelow.
parameters
min
max
Action
RSSI
85
20
none
MSE
45
15
none
BER
0.00E+0
1.00E4
none
BER
0.00E+0
1.00E4
none
IDUtemp
10
55
none
ODUtemp
40
58
none
Inportutil
0.0
100.0
none
Outportutil
0.0
100.0
none
ConfigurationStorage:Yes
thresholdwithoutanyparameterwilldisplaythecurrentstatusfor
thresholdsettinginformation
thresholdisadevicelevelcommand.
DESCRIPTION
thresholdcommandisusedtosetrulesformonitoringthesystem.
Wheneverthethresholdexceedstheprogrammedvaluesthedesired
actionisset.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
176
Theutilizationrateisexpressedaspercentageofthecurrentmax
speedbasedonthemodulation.
trap
SYNTAX
trap
trapenable<trap#><on|off>
trapip<trap#><ip_addr>
Default:seetable6.5
trap#
IP
enable
Trap1manager
0.0.0.0
OFF
Trap2manager
0.0.0.0
OFF
Trap3manager
0.0.0.0
OFF
Trap4manager
0.0.0.0
OFF
Trap5manager
0.0.0.0
OFF
ConfigurationStorage:Yes
trapwithoutanyparameterwilldisplaythecurrentstatusforthe
snmptrapinformation
trapisasystemlevelcommand.
DESCRIPTION
TrangoSystems,Inc.
trapisusedtoenableandconfiguretrapsandtheIPaddresswhich
theywillbesentto
GigaPlusUserManualRev1.3
177
uptime
SYNTAX
Uptime
DEFAULTVALUE
N/A
DESCRIPTION
Uptimeisusedtodisplayhowlongthesystemhasbeenrunning,since
thelastreboot/powercycle.
Itshowsthecurrenttimeanduptime.
EXAMPLE
Todisplaycurrentuptime
(trangoconfig)#uptime
20:45:58up1:49,loadaverage
RELATED
Date
utype
SYNTAX
utype
Default:N/A
ConfigurationStorage:N/A
utypewithoutanyparameterwilldisplaycurrentutypeandother
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
178
relatedstatus.
DESCRIPTION
EXAMPLE
Utypecommandwilldisplayunitscurrentutype,remoteunitstatus,
electionperiodstatusandsyncstatus.
Currentutype:Noutype,Active,orStandby
Protection:IndicatedifHWswichingprotectionisON/OFF,dependent
uponthestandbylinkstatusandguardtimeprotection.
Remoteunitstatus:nodetection,Standbydetected,activedetected
SyncStatus:Currentconfigurationsynchronizationstatus.
SynchronizedorNotsynchronized.
GuardTime:Currentlyuserconfiguredguardinterval.
FailoverCounter:#oftimestheunitshaveswitchedrolesfromactive
tostandbyandviceaversa
ElectionPeriod:yes(duringelectionperiod),no(notinelection
period)
DebugReg:Fordebugging
(CLIconfig)#utype
Currentutype:active
Protection:off
RedundancyCable:connected
RemoteUnitStatus:standbydetected
SyncStatus:Synchronized
GuardTime:15seconds
FailoverCounter:0
ElectionPeriod:no
DebugReg:(D6)0x00,(D5)0x00,(24)0x1F
utype_switch
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
179
utype_switch
Default:N/A
ConfigurationStorage:N/A
utype_switchdoesnottakeanyinputparameter.Willperformutype
switchfromActivetoStandby.
ThiscommandonlyallowedontheActiveunit.CanNOTbeinitiated
onStandbyunit
SYNTAX
DESCRIPTION
utype_switchmanuallyswitchtheActivetotheStandbyunitby
sendingSwitchoverREQtothestandbyunit.
Thiscommandismainlyusedforimageupgrades.Duringtheimage
upgrades,thestandbyunitcanupgradefirstandwhendone,perform
utype_switchovertomakethecurrentActiveunitStandbytocontinue
theupgradeprocess.
(CLIconfig)#utype
Currentutype:active
Remoteunitstatus:detectingastandby
ElectionPeriod:no
SyncStatus:Synchronized
EXAMPLE
version
Version
SYNTAX
DEFAULTVALUE
N/A
DESCRIPTION
TrangoSystems,Inc.
Versioncommandisusedtodisplaythecurrent/previoussoftware
GigaPlusUserManualRev1.3
180
imagesontheradio.Thesystemiscapableofhavemultipleimages.
RELATED
bootimage
voltage
SYNTAX
voltage
Default:N/A
ConfigurationStorage:No
voltagewithoutanyparameterwilldisplaythecurrentstatusforthe
IDUpowervoltageatdifferentsource
voltageisasystemlevelcommand.
DESCRIPTION
QuerythevoltagelevelatdifferentpowersourceonIDU.The
followingpowersourcearebeinglookat:
V1.25:
V2.5:
V3.3:
V5.0:
V12.0:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
181
AppendixBProductSpecifications
DimensionsandWeight
Parameter
Size
Specification
IDU:1.75x8.75x11.25in
HPODU:10.5x10.5x3.5in
HP2ODU:10.9x9.4x3.6in
Weight
IDU:4.8lbs/2.18kg
HPODU:10.1lbs/4.59kg
HP2ODU:9.5lbs/4.32kg
Environmental
Parameter
OperatingTemperatureRange
Specification
IDU:5degCto+55degC
ODU:40degCto+65degCFunctional
ODU:40degCto+55degCSpecCompliant
StorageTemperature
40degCto+75degC
Humidity
IDU:95%Noncondensing
ODU:100%Condensing
Waterresistance
IDU:NA
ODU:IP65perEN60529
SaltSpray
IDU:NA
ODU:PerIEC/EN6095022
Emissions
Parameter
Specification
ETSIConductedEmissions
EN55022(2006)ClassA
FCCConductedEmissions
FCC15.107(a)ClassA
ETSIRadiatedEmissions
EN55022(2006)ClassA
FCCRadiatedEmissions
FCC15.109(a)ClassA
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
182
Reliability
Parameter
MTBF
Specification
IDU:>18yearscalculated
ODU:>50yearsdemonstrated
ElectromagneticCompliance
Parameter
EMCtestmethods
Specification
EN3014891V1.8(200804)
EN3014894V1.4.1(200902)
PowerLineHarmonics
EN6100032:2006
PowerLineFluctuations/Flicker
EN6100033:2008
ElectrostaticDischarge(ESD)
EN6100042:2009
RadiatedRFimmunity
EN6100043:2004,Radiatedat3V/m
ElectricalFasttransients
EN6100044:2004
PowerLineSurgeImmunity
EN6100045:2006
PowerlineRFconductedimmunity
EN6100046:2005
VoltageDipsandShort
Interruptions
EN610001411:2004
WirelessCompliance
Parameter
FCC
Specification
CFR47Part101
CFR47Part15ClassAunintentionalradiator
Canada
SRSPxx
Europe(Harmonized)
EN30221721
EN30221722
Australia
RALIFX5
NewZealand
PIB22
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
183
WirelessParameters
Parameter
Specification
FrequencyRange
640GHz
ChannelSizesSupported
3.5,7,10,13.75,14,20,27.5,28,30,40,50,55,56,80MHz
FixedModulationSetLevels
QAM256,QAM128,QAM64,QAM32,QAM16,QPSK
TransmitterPowerAccuracy
+/2dB
TransmitterFrequencyAccuracy
+/7ppm
TransmitterCenterFrequency
Synthesizerstepsize
250kHz
TransmitterOutputPower(Muted)
<50dBm
TransmitterOutputReturnLoss
>10dB
AdaptiveModulationSetLevels
QAM256,QAM128,QAM64,QAM32,QAM16
AdaptiveModulationType
ErrorFree,Hitlessthrougheachtransition
AdaptiveModulationTransitions
Thresholds
UserSettable
AutomaticTransmitterPower
Control
>15dBrange,userconfigurablestepsizeandmaxpowerlimit
TransmitterPower
MaximumTransmitPowerbyFrequency(dBm)
Modulation
6,7,8
10
11
13,15
1826
2840
QPSK
30
26.5
28
26
25
23
16QAM
28
22.5
26
23
22
21
32QAM
28
22.5
26
23
22
21
64QAM
25
20.5
22
21
20
17
128QAM
25
20.5
22
21
20
17
256QAM
24
18.5
21
20
19
16
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
184
RadioSensitivity6to26GHz
BW
(Mhz)
Symbol
Rate
(Msps)
ReceiveSensitivityIndBm(626GHz)
QPSK
QAM16
QAM32
QAM64
QAM128
QAM256
96.6
90.4
86.4
84
80.9
77.9
5.6
93.3
87.7
83.7
81.3
78.2
75.2
10
8.32
92.2
86.0
82.0
79.6
76.5
73.5
14
12.2
90.5
84.3
80.3
77.9
74.8
71.8
20
17.42
89.0
82.8
78.8
76.4
73.3
70.3
28/30
26
87.3
81.1
77.1
74.7
71.6
68.6
40
34.83
86.0
79.8
75.8
73.4
70.3
67.3
50
43
85.1
78.9
74.9
72.5
69.4
66.4
55/56/80
49.5
84.5
78.3
*63.8dBmwhensettospeed80qam256
74.3
71.9
68.8
65.8*
RadioSensitivity28to38GHz
BW
(Mhz)
Symbol
Rate
(Msps)
ReceiveSensitivityIndBm(2838GHz)
QPSK
QAM16
QAM32
QAM64
QAM128
QAM256
93.6
87.4
83.4
81.0
77.9
74.9
5.6
90.9
84.7
80.7
78.3
75.2
72.2
10
8.32
89.2
83.0
79.0
76.6
73.5
70.5
14
12.2
87.5
81.3
77.3
74.9
71.8
68.8
20
17.42
86.0
79.8
75.8
73.4
70.3
67.3
28/30
26
84.4
78.1
74.1
71.7
68.6
65.6
40
34.83
83.0
76.8
72.8
70.4
67.3
64.3
50
43
82.1
75.9
71.9
69.5
66.4
63.4
55/56/80
49.5
81.5
75.3
*60.8dBmwhensettospeed80qam256
71.3
68.9
65.8
62.8*
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
185
1+1HotStandbyLinkProtection
Parameter
Specification
FailoverTime
150mSectypical
GuardTime
Userconfigurable10to60seconds
Power
Parameter
Specification
InputVoltageRange
40to72VDC
PowerConsumption
IDU:Max35Wattswithallportsactive
ODU:Typical25Watts,max50Watts
UserInterfaces
Description
Specification
EthernetTrafficPortsand/orIn
BandManagement(IBM)
ETH1andETH2:RJ45Jack10/100/1000BaseT
OutofBandManagement(OBM)
RJ45Jack10/100BaseT
T1/E1Ports18
RJ45Jack
AlarmInputs(2)
05VolthighimpedanceCMOSlevel
AlarmOutputs(2)
DB9Female,50Volt1Amprated,Drycontact
PowerInput
3PositionlatchingscrewterminalBlockwithlockingscrews
Console/CraftPort
DB9Male(requiresCBLDAT3)
1+1RedundancyPort
RJ45Jack(requiresCBLDATRIU3)
RSSIAlignment
BNCFemale(CBLDATRSSIrecommended)
ResetIP/Config
MomentaryPushButtononIDUfrontpanel
RebootSystem
MomentaryPushButtononIDUfrontpanel
Antenna
SlipFitCircularWaveguidefor740GHz
ETH3andETH4:SFP1000BaseTforSFPModule:
SFPGigEC(1000BaseT)
SFPGigES(1000BaseLXSingleModeFiber)
SFPGigEM(1000BaseLXMultimodeFiber)
SlipFitRectangularWaveguidefor6GHz
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
186
EthernetParameters
Parameter
Specification
PacketSize
649600Bytes,IPV4,IPV6
MaxCapacity
L1:414Mbps
L2:375Mbps
DataLatency
<100uSfor64bytepackets,Maxcapacity
(perRFC2544storeandforward)
QoS
802.1pPortPrioritization
Portmappingtoisolateports
VLANPriorityfortaggedpackets:
8ClassesofService
BandwidthShapingperport(IngressRatelimiting)
RSTP
RapidPortShutdownbothendsoflinkwithin50mSecoflinkdrop
T1/E1Parameters
Parameter
Specification
ClockSource
External
T1Compliance
T/O10021993
ITUT.G824
GR499CORE
T1BitRate
1544+/10ppm
T1Impedance
100OhmBalanced
T1LineCode
AMIorB8ZS
E1Compliance
ITUTG.703
ITUTG.823
E1BitRate
2048Kbps+/50ppm
E1Impedance
120OhmBalanced
E1LineCode
HDB3
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
187
AppendixCCableWiring
ThisappendixshowsthewiringofthevariousinterfacesontheGigaPlusunit.
EthernetCabling
TheFiguresbelowshowthecablepinoutsforstraightthroughandcrossoverEthernet
cables.TheimagesbelowconformtoEIA/TIAindustrystandardfor568AandB.
Ifthefirstandsecondpinsareorange,thecableis568B.Ifthefirstandsecondpinsare
green,thecableis568A(Figure46).
IfoneendofthecableisAandtheotherendisBitisacrossovercable.
Figure50EIA/TIA568AStraightthrough
Figure51EIA/TIA568BCrossOver
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
188
T1/E1Cabling
TheFigurebelowshowthecablepinoutsforT1/E1cablingtointerfacetotheRJ45
Jacksonthefrontpanel.
Table14T1/E1CableWiring
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
189
DB9PortInterfaces
DB9ConsolecablePinouts
TheconsolecableisanullmodemcablewithfemaleDB9connectors(Figure48)on
bothsides.ThepinoutsforcreatingaconsolecablearelistedinTable13.Trango
makesacablethatmeetstherequirementsbelowpartnumberCBLDAT3.
Figure52ConsoleCableConnector
ConsoleCablePinouts
IDU
Signal
Direction
PC
1,6
CD
IN
RxD
IN
TxD
OUT
DTR
OUT
1,6
GND
RTS
OUT
CTS
IN
Table15ConsoleCablePinouts
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
190
DB9AlarmPortPinouts
ThealarmportontheIDUisaDB9femaleconnector(Figure49).Thepinoutsofthe
alarmportarelistedinTable14
Figure53AlarmPortPinIdentification
Pins
Function
Relay1Com
Relay1NC
Relay1NO
Input1,05Vinput
Ground
Relay2Com
Relay2NC
Relay2NO
Input1,05Vinput
Table16AlarmPortPinFunctions
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
191
AppendixDMIBOIDListing
MIBIISystem
Object ID
.1.3.6.1.2.1.1.1.0
.1.3.6.1.2.1.1.2.0
.1.3.6.1.2.1.1.3.0
.1.3.6.1.2.1.1.4.0
.1.3.6.1.2.1.1.5.0
.1.3.6.1.2.1.1.6.0
TrangoSystems,Inc.
Name
sysDescr
sysObjectID
sysUpTime
sysContact
sysName
sysLocation
Type
DisplayString
OID
TimeTicks
DisplayString
DisplayString
DisplayString
Access
RO
RO
RO
RO
RO
RO
GigaPlusUserManualRev1.3
Range Limit
N/A
N/A
N/A
N/A
N/A
N/A
Default Value
GigaPlus-1.0
.1.3.6.1.4.1.5454.1.80
N/A
Tech Support
Administrator
USA
192
Trango
Object ID
.1.3.6.1.4.1.5454.1.80.1.1.1
.1.3.6.1.4.1.5454.1.80.1.1.2
.1.3.6.1.4.1.5454.1.80.1.1.3
.1.3.6.1.4.1.5454.1.80.1.1.4
.1.3.6.1.4.1.5454.1.80.1.1.5
.1.3.6.1.4.1.5454.1.80.1.1.6
.1.3.6.1.4.1.5454.1.80.1.2.1
.1.3.6.1.4.1.5454.1.80.1.2.2
.1.3.6.1.4.1.5454.1.80.1.2.3
.1.3.6.1.4.1.5454.1.80.1.2.4
.1.3.6.1.4.1.5454.1.80.1.2.5
.1.3.6.1.4.1.5454.1.80.1.2.6
.1.3.6.1.4.1.5454.1.80.1.3.1
.1.3.6.1.4.1.5454.1.80.1.3.2
.1.3.6.1.4.1.5454.1.80.1.3.3
.1.3.6.1.4.1.5454.1.80.1.3.4
.1.3.6.1.4.1.5454.1.80.1.4.1
.1.3.6.1.4.1.5454.1.80.1.4.2
.1.3.6.1.4.1.5454.1.80.1.4.3
.1.3.6.1.4.1.5454.1.80.1.5.1
.1.3.6.1.4.1.5454.1.80.1.5.2
.1.3.6.1.4.1.5454.1.80.1.5.3
.1.3.6.1.4.1.5454.1.80.1.5.4
.1.3.6.1.4.1.5454.1.80.1.6.1
.1.3.6.1.4.1.5454.1.80.1.7.1
.1.3.6.1.4.1.5454.1.80.1.7.2
.1.3.6.1.4.1.5454.1.80.1.7.3
.1.3.6.1.4.1.5454.1.80.1.7.4
.1.3.6.1.4.1.5454.1.80.1.7.5
.1.3.6.1.4.1.5454.1.80.1.8.1
.1.3.6.1.4.1.5454.1.80.1.8.2
.1.3.6.1.4.1.5454.1.80.1.8.3
.1.3.6.1.4.1.5454.1.80.1.9.1.1
.1.3.6.1.4.1.5454.1.80.1.9.1.2
.1.3.6.1.4.1.5454.1.80.1.9.2.1
.1.3.6.1.4.1.5454.1.80.1.9.2.2
.1.3.6.1.4.1.5454.1.80.1.9.3.1
.1.3.6.1.4.1.5454.1.80.1.9.3.2
.1.3.6.1.4.1.5454.1.80.1.9.4.1
.1.3.6.1.4.1.5454.1.80.1.9.4.2
.1.3.6.1.4.1.5454.1.80.1.9.5.1
.1.3.6.1.4.1.5454.1.80.1.9.5.2
.1.3.6.1.4.1.5454.1.80.1.10.1
.1.3.6.1.4.1.5454.1.80.1.10.2
.1.3.6.1.4.1.5454.1.80.1.10.3
Name
sysFPGAVer
sysOSVer
sysFWVer
sysPICVer
sysModemVer
sysODUFWVer
sysFPGAPreVer
sysOSPreVer
sysFWPreVer
sysPICPreVer
sysModemPreVer
sysODUFWPreVer
sysIDUModel
sysIDUSerialID
sysODUModel
sysODUSerialID
sysMACeth1
sysMACeth2
sysReserved1
sysIpAddress
sysSubnetMask
sysDefaultGateway
sysRemoteIp
sysRemarkSystem
sysIBMEnable
sysIBMIp
sysIBMNetmask
sysIBMVlanID
sysIBMVlanPort
sysSNMPReadCommStr
sysSNMPWriteCommStr
sysSNMPTrapCommStr
sysSNMPTrap1Enable
sysSNMPTrap1Ip
sysSNMPTrap2Enable
sysSNMPTrap2Ip
sysSNMPTrap3Enable
sysSNMPTrap3Ip
sysSNMPTrap4Enable
sysSNMPTrap4Ip
sysSNMPTrap5Enable
sysSNMPTrap5Ip
sysImageUpgrade
sysImageUpgradeStatus
sysImageToggle
Type
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
Integer
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
IpAddr
IpAddr
IpAddr
IpAddr
DisplayString
Integer
IpAddr
IpAddr
Integer
Integer
DisplayString
DisplayString
DisplayString
Integer
IpAddr
Integer
IpAddr
Integer
IpAddr
Integer
IpAddr
Integer
IpAddr
Integer
Integer
Integer
Access
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RO
RW
.1.3.6.1.4.1.5454.1.80.1.11
.1.3.6.1.4.1.5454.1.80.1.12.1
.1.3.6.1.4.1.5454.1.80.1.12.2
.1.3.6.1.4.1.5454.1.80.1.13.1
.1.3.6.1.4.1.5454.1.80.1.13.2
.1.3.6.1.4.1.5454.1.80.1.14
sysConfigOption
sysDiagnostic
sysDiagnosticStatus
sysSyslogExport
sysSyslogLevel
sysReboot
Integer
Integer
Integer
Integer
Integer
Integer
RW
RW
RO
RW
RW
RW
.1.3.6.1.4.1.5454.1.80.1.15
sysResetOption
Integer
RW
.1.3.6.1.4.1.5454.1.80.1.16
.1.3.6.1.4.1.5454.1.80.1.17.1
.1.3.6.1.4.1.5454.1.80.1.17.2
sysDatapath
sysAlarm1
sysAlarm2
Integer
Integer
Integer
RW
RW
RW
.1.3.6.1.4.1.5454.1.80.1.18
sysFanCtrl
Integer
RW
Range Limit
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
string size 1..100
0(Off), 1(On)
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
0-4090
1 4
string size 1-32
string size 1-32
string size 1-32
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
1(IDU), 2(ODU)
0(NA), 1(Failed)
1(Toggle)
1(Export), 2(Import),
3(Remove), 4(Save)
1(Export)
0(NA), 1(Failed)
1(Export), 2(Clear)
1(REBOOT)
0(Factory Default), 1(IP),
2(License)
0(ETH only), 1(ETH+T1),
2(ETH+E1)
0(Off), 1(On)
0(Off), 1(On)
0(FanOff), 1(Fan1On), 2
(Fan2On)
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
192.168.100.100
255.255.255.0
192.168.100.100
0.0.0.0
TrangoLink GigaPro
0(Off)
172.168.1.1
255.255.0.0
1
ge1
public
private
trapstr
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0 (NA)
0(NA)
0(NA)
0(NA)
0(NA)
0(NA)
0(NA)
3
0 (NA)
0 (NA)
0(ETH only)
0(Off)
0(Off)
1(Fan1On)
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
193
Trango,contd
.1.3.6.1.4.1.5454.1.80.1.19
.1.3.6.1.4.1.5454.1.80.1.20.1
.1.3.6.1.4.1.5454.1.80.1.20.2
.1.3.6.1.4.1.5454.1.80.1.20.3
.1.3.6.1.4.1.5454.1.80.1.20.4
.1.3.6.1.4.1.5454.1.80.1.20.5
.1.3.6.1.4.1.5454.1.80.1.21
.1.3.6.1.4.1.5454.1.80.1.22
.1.3.6.1.4.1.5454.1.80.1.23.1
.1.3.6.1.4.1.5454.1.80.1.23.2
.1.3.6.1.4.1.5454.1.80.1.24.1.1
.1.3.6.1.4.1.5454.1.80.1.24.1.2
.1.3.6.1.4.1.5454.1.80.1.24.1.3
.1.3.6.1.4.1.5454.1.80.1.24.2.1
.1.3.6.1.4.1.5454.1.80.1.24.2.2
.1.3.6.1.4.1.5454.1.80.1.25
sysIDUTemp
sysReserved2
sysHTTPD
sysSNMPD
sysTFTPD
sysTelnetD
sysRPSEnable
sysClearCounter
sysTdmMode
sysTdmCoding
sysSpeedLicenseEnable
sysSpeedLicenseKey1
sysSpeedLicenseKey2
sysTDMLicenseEnable
sysTDMLicenseKey
sysIDULED
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
String
String
Integer
String
Integer
RO
RW
RW
RO
RW
RW
RW
RW
RO
RO
RO
RW
RW
RO
RW
RW
.1.3.6.1.4.1.5454.1.80.1.26
sysFailoverMode
Integer
RW
.1.3.6.1.4.1.5454.1.80.1.27
.1.3.6.1.4.1.5454.1.80.1.28
.1.3.6.1.4.1.5454.1.80.1.29.1
.1.3.6.1.4.1.5454.1.80.1.29.2
.1.3.6.1.4.1.5454.1.80.1.29.3
.1.3.6.1.4.1.5454.1.80.1.29.4
.1.3.6.1.4.1.5454.1.80.1.30
sysUtype
sysSync
sysRemoteLinkStatus
sysRemoteODUStatus
sysRemoteRSSI
sysRemoteMSE
sysGuardTime
Integer
Integer
Integer
Integer
Integer
Integer
Integer
RO
RW
RO
RO
RO
RO
RW
TrangoSystems,Inc.
N/A
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
1(Clear)
0(T1), 1(E1)
0(AMI), 1(B8ZS), 2(HDB3)
0(Disable), 1(Enable)
N/A
N/A
0(Disable), 1(Enable)
N/A
0(RSSI), 1 (TDM)
0(Off), 1(ON with port OFF),
2(ON with port ON)
0(NO Utype), 1 (Active),
2(Standby)
1(sync)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
N/A
N/A
10-60 seconds
GigaPlusUserManualRev1.3
N/A
0(Off)
1(On)
1(On)
0(Off)
1(On)
0(Off)
0(NA)
0(T1)
0(AMI)
0(Disable)
N/A
N/A
0(Disable)
N/A
0(RSSI)
0
1(Active)
N/A
N/A
N/A
N/A
N/A
15 second
194
ModemSection
Object ID
.1.3.6.1.4.1.5454.1.80.2.1
.1.3.6.1.4.1.5454.1.80.2.2
.1.3.6.1.4.1.5454.1.80.2.3.1
.1.3.6.1.4.1.5454.1.80.2.3.2.1
.1.3.6.1.4.1.5454.1.80.2.3.2.2
.1.3.6.1.4.1.5454.1.80.2.3.2.3
.1.3.6.1.4.1.5454.1.80.2.3.2.4
.1.3.6.1.4.1.5454.1.80.2.3.2.5
.1.3.6.1.4.1.5454.1.80.2.3.2.6
.1.3.6.1.4.1.5454.1.80.2.3.3.1.1
.1.3.6.1.4.1.5454.1.80.2.3.3.1.2
.1.3.6.1.4.1.5454.1.80.2.3.3.2.1
.1.3.6.1.4.1.5454.1.80.2.3.3.2.2
.1.3.6.1.4.1.5454.1.80.2.3.3.3.1
.1.3.6.1.4.1.5454.1.80.2.3.3.3.2
.1.3.6.1.4.1.5454.1.80.2.3.3.4.1
.1.3.6.1.4.1.5454.1.80.2.3.3.4.2
.1.3.6.1.4.1.5454.1.80.2.3.3.5.1
.1.3.6.1.4.1.5454.1.80.2.3.3.5.2
.1.3.6.1.4.1.5454.1.80.2.3.3.6.1
.1.3.6.1.4.1.5454.1.80.2.3.3.6.2
.1.3.6.1.4.1.5454.1.80.2.3.4.1.1
.1.3.6.1.4.1.5454.1.80.2.3.4.1.2
.1.3.6.1.4.1.5454.1.80.2.3.4.2.1
.1.3.6.1.4.1.5454.1.80.2.3.4.2.2
.1.3.6.1.4.1.5454.1.80.2.3.4.3.1
.1.3.6.1.4.1.5454.1.80.2.3.4.3.2
.1.3.6.1.4.1.5454.1.80.2.3.4.4.1
.1.3.6.1.4.1.5454.1.80.2.3.4.4.2
.1.3.6.1.4.1.5454.1.80.2.3.4.5.1
.1.3.6.1.4.1.5454.1.80.2.3.4.5.2
.1.3.6.1.4.1.5454.1.80.2.3.4.6.1
.1.3.6.1.4.1.5454.1.80.2.3.4.6.2
Name
Access
modemLoopbackMode
modemDataPattern
modemACMEnable
modemACMProfileQPSKEnable
modemACMProfile16QEnable
modemACMProfile32QEnable
modemACMProfile64QEnable
modemACMProfile128QEnable
modemACMProfile256QEnable
modemACMQPSKMSEImprove
modemACMQPSKMSEImproveInt
modemACM16QMSEImprove
modemACM16QMSEImproveInt
modemACM32QMSEImprove
modemACM32QMSEImproveInt
modemACM64QMSEImprove
modemACM64QMSEImproveInt
modemACM128QMSEImprove
modemACM128QMSEImproveInt
modemACM256QMSEImprove
modemACM256QMSEImproveInt
modemACMQPSKMSEDegrade
modemACMQPSKMSEDegrade
modemACM16QMSEDegrade
modemACM16QMSEDegradeInt
modemACM32QMSEDegrade
modemACM32QMSEDegradeInt
modemACM64QMSEDegrade
modemACM64QMSEDegradeInt
modemACM128QMSEDegrade
modemACM128QMSEDegradeInt
modemACM256QMSEDegrade
modemACM256QMSEDegradeInt
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
RW
RW
RW
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
.1.3.6.1.4.1.5454.1.80.2.3.5.1
modemACMTxProfile
Integer
RO
.1.3.6.1.4.1.5454.1.80.2.3.5.2
.1.3.6.1.4.1.5454.1.80.2.4.1
.1.3.6.1.4.1.5454.1.80.2.4.2
.1.3.6.1.4.1.5454.1.80.2.4.3
.1.3.6.1.4.1.5454.1.80.2.5.1
.1.3.6.1.4.1.5454.1.80.2.5.2
.1.3.6.1.4.1.5454.1.80.2.5.3
.1.3.6.1.4.1.5454.1.80.2.5.4
modemACMRxProfile
modemBER
modemMSE
modemFER
modemLockStatus
modemTimingLock
modemPreambleLock
modemLDPCLock
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
RO
RO
RO
RO
RO
RO
RO
RO
Range Limit
0(Off), 1(Digital), 2(IF),
3(Rf_gen), 4(Rf_refl)
0(FPGA), 1(Modem)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
(-45) ~ 0
Default Value
(-45) ~ 0
-25.3
(-45) ~ 0
-26.3
(-45) ~ 0
-29.2
(-45) ~ 0
-32.1
(-45) ~ 0
-32.1
(-45) ~ 0
-17.1
(-45) ~ 0
-18.5
(-45) ~ 0
-21.3
(-45) ~ 0
-24.3
(-45) ~ 0
-27.2
(-45) ~ 0
-27.2
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
N/A
N/A
N/A
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(Off)
0(FPGA)
0(Off)
1(On)
1(On)
1(On)
1(On)
1(On)
1(On)
-20.3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
195
RFSection
Object ID
Access
Range Limit
Default Value
Opaque(Float)
RW
Integer
RW
Opaque(Float)
RO
Integer
RO
Name
.1.3.6.1.4.1.5454.1.80.3.1.1.1
rfTxFrequency
.1.3.6.1.4.1.5454.1.80.3.1.1.1
rfTxFrequencyInt
.1.3.6.1.4.1.5454.1.80.3.1.2.1
rfRxFrequency
.1.3.6.1.4.1.5454.1.80.3.1.2.1
rfRxFrequencyInt
.1.3.6.1.4.1.5454.1.80.3.1.3.1
rfFreqDuplex
Opaque(Float)
RW
.1.3.6.1.4.1.5454.1.80.3.1.3.1
.1.3.6.1.4.1.5454.1.80.3.2
.1.3.6.1.4.1.5454.1.80.3.3
.1.3.6.1.4.1.5454.1.80.3.4.1
.1.3.6.1.4.1.5454.1.80.3.4.2
.1.3.6.1.4.1.5454.1.80.3.5.1.1
.1.3.6.1.4.1.5454.1.80.3.5.1.2
.1.3.6.1.4.1.5454.1.80.3.5.2.1
.1.3.6.1.4.1.5454.1.80.3.5.2.2
.1.3.6.1.4.1.5454.1.80.3.5.3.1
.1.3.6.1.4.1.5454.1.80.3.5.3.2
.1.3.6.1.4.1.5454.1.80.3.6.1
rfFreqDuplexInt
rfDefaultOpmode
rfOpmode
rfPower
rfPowerInt
rfCableloss140
rfCableloss140Int
rfCableloss350
rfCableloss350Int
rfCableloss915
rfCableloss915Int
rfChannelsWidth
Integer
Integer
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Integer
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
0
0(Off)
0(Off)
10
100
0
0
0
0
0
0
20
.1.3.6.1.4.1.5454.1.80.3.6.2
.1.3.6.1.4.1.5454.1.80.3.6.3.1
.1.3.6.1.4.1.5454.1.80.3.6.3.2
.1.3.6.1.4.1.5454.1.80.3.6.4.1
.1.3.6.1.4.1.5454.1.80.3.6.4.2
.1.3.6.1.4.1.5454.1.80.3.7.1
.1.3.6.1.4.1.5454.1.80.3.7.2
.1.3.6.1.4.1.5454.1.80.3.7.3
.1.3.6.1.4.1.5454.1.80.3.8
.1.3.6.1.4.1.5454.1.80.3.9.1
rfModulation
rfSymrate
rfSymrateInt
rfSpeed
rfSpeedInt
rfATPCEnable
rfATPCMaxPower
rfATPCStepSize
rfAlignmentMode
rfTargetRSSI
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Integer
Integer
Integer
Integer
Opaque(Float)
RW
RO
RO
RO
RO
RW
RW
RW
RW
RW
QAM128
24.6
N/A
110
0(Off), 1(On)
ODU model dependant
0-5
0(Off), 1(On)
(-88) ~ (-25)
0(Off)
ODU model dependant
1
0(Off)
-40
.1.3.6.1.4.1.5454.1.80.3.9.2
.1.3.6.1.4.1.5454.1.80.3.10
.1.3.6.1.4.1.5454.1.80.3.11
.1.3.6.1.4.1.5454.1.80.3.12
.1.3.6.1.4.1.5454.1.80.3.13
.1.3.6.1.4.1.5454.1.80.3.14
.1.3.6.1.4.1.5454.1.80.3.15.1
.1.3.6.1.4.1.5454.1.80.3.15.2
.1.3.6.1.4.1.5454.1.80.3.15.3
.1.3.6.1.4.1.5454.1.80.3.15.4
.1.3.6.1.4.1.5454.1.80.3.15.5
.1.3.6.1.4.1.5454.1.80.3.16.1
.1.3.6.1.4.1.5454.1.80.3.16.2
.1.3.6.1.4.1.5454.1.80.3.16.3
.1.3.6.1.4.1.5454.1.80.3.16.4
.1.3.6.1.4.1.5454.1.80.3.16.5
.1.3.6.1.4.1.5454.1.80.3.17.1
.1.3.6.1.4.1.5454.1.80.3.17.2
.1.3.6.1.4.1.5454.1.80.3.17.3
.1.3.6.1.4.1.5454.1.80.3.17.4
rfTargetRSSIInt
rfODULEDEnable
rfODUPowerEnable
rfODURxAGCEnable
rfODUTemp
rfRSSI
rfODURFpll
rfODUIFpll
rfODUTxpll
rfODURxpll
rfIDUTxpll
rfInDataOctets
rfInDataPackets
rfInDropPackets
rfInPortRate
rfInPortUtil
rfOutDataOctets
rfOutDataPackets
rfOutPortRate
rfOutPortUtil
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
-40
1(On)
0(Off)
0(Off)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
N/A
N/A
N/A
N/A
N/A
196
EthernetSection
Object ID
.1.3.6.1.4.1.5454.1.80.4.1.1.1
.1.3.6.1.4.1.5454.1.80.4.1.1.2
.1.3.6.1.4.1.5454.1.80.4.1.1.3
.1.3.6.1.4.1.5454.1.80.4.1.1.4
.1.3.6.1.4.1.5454.1.80.4.1.1.5
.1.3.6.1.4.1.5454.1.80.4.1.1.6
.1.3.6.1.4.1.5454.1.80.4.1.1.7
.1.3.6.1.4.1.5454.1.80.4.1.1.8
.1.3.6.1.4.1.5454.1.80.4.1.2.1
.1.3.6.1.4.1.5454.1.80.4.1.2.2
.1.3.6.1.4.1.5454.1.80.4.1.2.3
.1.3.6.1.4.1.5454.1.80.4.1.2.4
.1.3.6.1.4.1.5454.1.80.4.1.2.5
.1.3.6.1.4.1.5454.1.80.4.1.2.6
.1.3.6.1.4.1.5454.1.80.4.1.2.7
.1.3.6.1.4.1.5454.1.80.4.1.2.8
.1.3.6.1.4.1.5454.1.80.4.1.2.9
.1.3.6.1.4.1.5454.1.80.4.1.2.10
.1.3.6.1.4.1.5454.1.80.4.2.1.1
.1.3.6.1.4.1.5454.1.80.4.2.1.2
.1.3.6.1.4.1.5454.1.80.4.2.1.3
.1.3.6.1.4.1.5454.1.80.4.2.1.4
.1.3.6.1.4.1.5454.1.80.4.2.1.5
.1.3.6.1.4.1.5454.1.80.4.2.1.6
.1.3.6.1.4.1.5454.1.80.4.2.1.7
.1.3.6.1.4.1.5454.1.80.4.2.1.8
.1.3.6.1.4.1.5454.1.80.4.2.2.1
.1.3.6.1.4.1.5454.1.80.4.2.2.2
.1.3.6.1.4.1.5454.1.80.4.2.2.3
.1.3.6.1.4.1.5454.1.80.4.2.2.4
.1.3.6.1.4.1.5454.1.80.4.2.2.5
.1.3.6.1.4.1.5454.1.80.4.2.2.6
.1.3.6.1.4.1.5454.1.80.4.2.2.7
.1.3.6.1.4.1.5454.1.80.4.2.2.8
.1.3.6.1.4.1.5454.1.80.4.2.2.9
.1.3.6.1.4.1.5454.1.80.4.2.2.10
.1.3.6.1.4.1.5454.1.80.4.3.1.1
.1.3.6.1.4.1.5454.1.80.4.3.1.2
.1.3.6.1.4.1.5454.1.80.4.3.1.3
.1.3.6.1.4.1.5454.1.80.4.3.1.4
.1.3.6.1.4.1.5454.1.80.4.3.1.5
.1.3.6.1.4.1.5454.1.80.4.3.1.6
.1.3.6.1.4.1.5454.1.80.4.3.1.7
Name
gigeEth1AutoNegotiate
gigeEth1Duplex
gigeEth1Enable
gigeEth1MaxRate
gigeEth1PauseFrame
gigeEth1Priority
gigeEth1Speed
gigeEth1Status
gigeEth1InOctets
gigeEth1InUcastPackets
gigeEth1InNUcastPackets
gigeEth1InTotalPackets
gigeEth1OutOctets
gigeEth1OutUcastPackets
gigeEth1OutNUcastPackets
gigeEth1OutTotalPackets
gigeEth1CRCErrors
gigeEth1CollisionErrors
gigeEth2AutoNegotiate
gigeEth2Duplex
gigeEth2Enable
gigeEth2MaxRate
gigeEth2PauseFrame
gigeEth2Priority
gigeEth2Speed
gigeEth2Status
gigeEth2InOctets
gigeEth2InUcastPackets
gigeEth2InNUcastPackets
gigeEth2InTotalPackets
gigeEth2OutOctets
gigeEth2OutUcastPackets
gigeEth2OutNUcastPackets
gigeEth2OutTotalPackets
gigeEth2CRCErrors
gigeEth2CollisionErrors
gigeEth3AutoNegotiate
gigeEth3Duplex
gigeEth3Enable
gigeEth3MaxRate
gigeEth3PauseFrame
gigeEth3Priority
gigeEth3Speed
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Access
RW
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
Range Limit
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000
0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000
0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000
Default Value
1(On)
1(Full)
1(On)
1000
0(Off)
0
1000
N/A
1(On)
1(Full)
1(On)
1000
0(Off)
0
1000
N/A
1(On)
1(Full)
1(On)
1000
0(Off)
0
1000
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
197
EthernetSection,Contd
.1.3.6.1.4.1.5454.1.80.4.3.1.8
.1.3.6.1.4.1.5454.1.80.4.3.2.1
.1.3.6.1.4.1.5454.1.80.4.3.2.2
.1.3.6.1.4.1.5454.1.80.4.3.2.3
.1.3.6.1.4.1.5454.1.80.4.3.2.4
.1.3.6.1.4.1.5454.1.80.4.3.2.5
.1.3.6.1.4.1.5454.1.80.4.3.2.6
.1.3.6.1.4.1.5454.1.80.4.3.2.7
.1.3.6.1.4.1.5454.1.80.4.3.2.8
.1.3.6.1.4.1.5454.1.80.4.3.2.9
.1.3.6.1.4.1.5454.1.80.4.3.2.10
.1.3.6.1.4.1.5454.1.80.4.4.1.1
.1.3.6.1.4.1.5454.1.80.4.4.1.2
.1.3.6.1.4.1.5454.1.80.4.4.1.3
.1.3.6.1.4.1.5454.1.80.4.4.1.4
.1.3.6.1.4.1.5454.1.80.4.4.1.5
.1.3.6.1.4.1.5454.1.80.4.4.1.6
.1.3.6.1.4.1.5454.1.80.4.4.1.7
.1.3.6.1.4.1.5454.1.80.4.4.1.8
.1.3.6.1.4.1.5454.1.80.4.4.2.1
.1.3.6.1.4.1.5454.1.80.4.4.2.2
.1.3.6.1.4.1.5454.1.80.4.4.2.3
.1.3.6.1.4.1.5454.1.80.4.4.2.4
.1.3.6.1.4.1.5454.1.80.4.4.2.5
.1.3.6.1.4.1.5454.1.80.4.4.2.6
.1.3.6.1.4.1.5454.1.80.4.4.2.7
.1.3.6.1.4.1.5454.1.80.4.4.2.8
.1.3.6.1.4.1.5454.1.80.4.4.2.9
.1.3.6.1.4.1.5454.1.80.4.4.2.10
.1.3.6.1.4.1.5454.1.80.4.7.1
.1.3.6.1.4.1.5454.1.80.4.7.2
.1.3.6.1.4.1.5454.1.80.4.7.3
.1.3.6.1.4.1.5454.1.80.4.7.4
.1.3.6.1.4.1.5454.1.80.4.7.5
.1.3.6.1.4.1.5454.1.80.4.7.6
.1.3.6.1.4.1.5454.1.80.4.7.7
.1.3.6.1.4.1.5454.1.80.4.7.8
TrangoSystems,Inc.
gigeEth3Status
gigeEth3InOctets
gigeEth3InUcastPackets
gigeEth3InNUcastPackets
gigeEth3InTotalPackets
gigeEth3OutOctets
gigeEth3OutUcastPackets
gigeEth3OutNUcastPackets
gigeEth3OutTotalPackets
gigeEth3CRCErrors
gigeEth3CollisionErrors
gigeEth4AutoNegotiate
gigeEth4Duplex
gigeEth4Enable
gigeEth4MaxRate
gigeEth4PauseFrame
gigeEth4Priority
gigeEth4Speed
gigeEth4Status
gigeEth4InOctets
gigeEth4InUcastPackets
gigeEth4InNUcastPackets
gigeEth4InTotalPackets
gigeEth4OutOctets
gigeEth4OutUcastPackets
gigeEth4OutNUcastPackets
gigeEth4OutTotalPackets
gigeEth4CRCErrors
gigeEth4CollisionErrors
gigeEthPriority0COSQueue
gigeEthPriority1COSQueue
gigeEthPriority2COSQueue
gigeEthPriority3COSQueue
gigeEthPriority4COSQueue
gigeEthPriority5COSQueue
gigeEthPriority6COSQueue
gigeEthPriority7COSQueue
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW
GigaPlusUserManualRev1.3
0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000
0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-3
0-3
0-3
0-3
0-3
0-3
0-3
0-3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1(On)
1(Full)
1(On)
1000
0(Off)
0
1000
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0
0
1
1
2
2
3
3
198
TDMSection
Integer
Access
RO
Range Limit
0(Off), 1(On)
Default Value
0(Off)
tdmPort1CableConfig
tdmPort1CounterCrcBlockErrors
tdmPort1CounterExCrcErrors
tdmPort1CounterFBAErrors
tdmPort1CounterFEBErrors
tdmPort1CounterLCViolations
tdmPort1EventLOS
tdmPort1EventLOF
tdmPort1EventAIS
tdmPort1EventTS16AIS
tdmPort1EventRAI
tdmPort1EventRMA
tdmPort1EventLCMFA
tdmPort1EventLSMFA
tdmPort2Status
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)
.1.3.6.1.4.1.5454.1.80.5.2.1.2
.1.3.6.1.4.1.5454.1.80.5.2.2.1
.1.3.6.1.4.1.5454.1.80.5.2.2.2
.1.3.6.1.4.1.5454.1.80.5.2.2.3
.1.3.6.1.4.1.5454.1.80.5.2.2.4
.1.3.6.1.4.1.5454.1.80.5.2.2.5
.1.3.6.1.4.1.5454.1.80.5.2.3.1
.1.3.6.1.4.1.5454.1.80.5.2.3.2
.1.3.6.1.4.1.5454.1.80.5.2.3.3
.1.3.6.1.4.1.5454.1.80.5.2.3.4
.1.3.6.1.4.1.5454.1.80.5.2.3.5
.1.3.6.1.4.1.5454.1.80.5.2.3.6
.1.3.6.1.4.1.5454.1.80.5.2.3.7
.1.3.6.1.4.1.5454.1.80.5.2.3.8
.1.3.6.1.4.1.5454.1.80.5.3.1.1
tdmPort2CableConfig
tdmPort2CounterCrcBlockErrors
tdmPort2CounterExCrcErrors
tdmPort2CounterFBAErrors
tdmPort2CounterFEBErrors
tdmPort2CounterLCViolations
tdmPort2EventLOS
tdmPort2EventLOF
tdmPort2EventAIS
tdmPort2EventTS16AIS
tdmPort2EventRAI
tdmPort2EventRMA
tdmPort2EventLCMFA
tdmPort2EventLSMFA
tdmPort3Status
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)
.1.3.6.1.4.1.5454.1.80.5.3.1.2
.1.3.6.1.4.1.5454.1.80.5.3.2.1
.1.3.6.1.4.1.5454.1.80.5.3.2.2
.1.3.6.1.4.1.5454.1.80.5.3.2.3
.1.3.6.1.4.1.5454.1.80.5.3.2.4
.1.3.6.1.4.1.5454.1.80.5.3.2.5
.1.3.6.1.4.1.5454.1.80.5.3.3.1
.1.3.6.1.4.1.5454.1.80.5.3.3.2
.1.3.6.1.4.1.5454.1.80.5.3.3.3
.1.3.6.1.4.1.5454.1.80.5.3.3.4
.1.3.6.1.4.1.5454.1.80.5.3.3.5
.1.3.6.1.4.1.5454.1.80.5.3.3.6
.1.3.6.1.4.1.5454.1.80.5.3.3.7
.1.3.6.1.4.1.5454.1.80.5.3.3.8
tdmPort3CableConfig
tdmPort3CounterCrcBlockErrors
tdmPort3CounterExCrcErrors
tdmPort3CounterFBAErrors
tdmPort3CounterFEBErrors
tdmPort3CounterLCViolations
tdmPort3EventLOS
tdmPort3EventLOF
tdmPort3EventAIS
tdmPort3EventTS16AIS
tdmPort3EventRAI
tdmPort3EventRMA
tdmPort3EventLCMFA
tdmPort3EventLSMFA
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Object ID
.1.3.6.1.4.1.5454.1.80.5.1.1.1
Name
tdmPort1Status
.1.3.6.1.4.1.5454.1.80.5.1.1.2
.1.3.6.1.4.1.5454.1.80.5.1.2.1
.1.3.6.1.4.1.5454.1.80.5.1.2.2
.1.3.6.1.4.1.5454.1.80.5.1.2.3
.1.3.6.1.4.1.5454.1.80.5.1.2.4
.1.3.6.1.4.1.5454.1.80.5.1.2.5
.1.3.6.1.4.1.5454.1.80.5.1.3.1
.1.3.6.1.4.1.5454.1.80.5.1.3.2
.1.3.6.1.4.1.5454.1.80.5.1.3.3
.1.3.6.1.4.1.5454.1.80.5.1.3.4
.1.3.6.1.4.1.5454.1.80.5.1.3.5
.1.3.6.1.4.1.5454.1.80.5.1.3.6
.1.3.6.1.4.1.5454.1.80.5.1.3.7
.1.3.6.1.4.1.5454.1.80.5.1.3.8
.1.3.6.1.4.1.5454.1.80.5.2.1.1
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
199
TDMSection,Contd
.1.3.6.1.4.1.5454.1.80.5.4.1.1
tdmPort4Status
Integer
RO
0(Off), 1(On)
0(Off)
.1.3.6.1.4.1.5454.1.80.5.4.1.2
.1.3.6.1.4.1.5454.1.80.5.4.2.1
.1.3.6.1.4.1.5454.1.80.5.4.2.2
.1.3.6.1.4.1.5454.1.80.5.4.2.3
.1.3.6.1.4.1.5454.1.80.5.4.2.4
.1.3.6.1.4.1.5454.1.80.5.4.2.5
.1.3.6.1.4.1.5454.1.80.5.4.3.1
.1.3.6.1.4.1.5454.1.80.5.4.3.2
.1.3.6.1.4.1.5454.1.80.5.4.3.3
.1.3.6.1.4.1.5454.1.80.5.4.3.4
.1.3.6.1.4.1.5454.1.80.5.4.3.5
.1.3.6.1.4.1.5454.1.80.5.4.3.6
.1.3.6.1.4.1.5454.1.80.5.4.3.7
.1.3.6.1.4.1.5454.1.80.5.4.3.8
.1.3.6.1.4.1.5454.1.80.5.5.1.1
tdmPort4CableConfig
tdmPort4CounterCrcBlockErrors
tdmPort4CounterExCrcErrors
tdmPort4CounterFBAErrors
tdmPort4CounterFEBErrors
tdmPort4CounterLCViolations
tdmPort4EventLOS
tdmPort4EventLOF
tdmPort4EventAIS
tdmPort4EventTS16AIS
tdmPort4EventRAI
tdmPort4EventRMA
tdmPort4EventLCMFA
tdmPort4EventLSMFA
tdmPort5Status
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)
.1.3.6.1.4.1.5454.1.80.5.5.1.2
.1.3.6.1.4.1.5454.1.80.5.5.2.1
.1.3.6.1.4.1.5454.1.80.5.5.2.2
.1.3.6.1.4.1.5454.1.80.5.5.2.3
.1.3.6.1.4.1.5454.1.80.5.5.2.4
.1.3.6.1.4.1.5454.1.80.5.5.2.5
.1.3.6.1.4.1.5454.1.80.5.5.3.1
.1.3.6.1.4.1.5454.1.80.5.5.3.2
.1.3.6.1.4.1.5454.1.80.5.5.3.3
.1.3.6.1.4.1.5454.1.80.5.5.3.4
.1.3.6.1.4.1.5454.1.80.5.5.3.5
.1.3.6.1.4.1.5454.1.80.5.5.3.6
.1.3.6.1.4.1.5454.1.80.5.5.3.7
.1.3.6.1.4.1.5454.1.80.5.5.3.8
.1.3.6.1.4.1.5454.1.80.5.6.1.1
tdmPort5CableConfig
tdmPort5CounterCrcBlockErrors
tdmPort5CounterExCrcErrors
tdmPort5CounterFBAErrors
tdmPort5CounterFEBErrors
tdmPort5CounterLCViolations
tdmPort5EventLOS
tdmPort5EventLOF
tdmPort5EventAIS
tdmPort5EventTS16AIS
tdmPort5EventRAI
tdmPort5EventRMA
tdmPort5EventLCMFA
tdmPort5EventLSMFA
tdmPort6Status
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)
.1.3.6.1.4.1.5454.1.80.5.6.1.2
.1.3.6.1.4.1.5454.1.80.5.6.2.1
.1.3.6.1.4.1.5454.1.80.5.6.2.2
.1.3.6.1.4.1.5454.1.80.5.6.2.3
.1.3.6.1.4.1.5454.1.80.5.6.2.4
.1.3.6.1.4.1.5454.1.80.5.6.2.5
.1.3.6.1.4.1.5454.1.80.5.6.3.1
.1.3.6.1.4.1.5454.1.80.5.6.3.2
.1.3.6.1.4.1.5454.1.80.5.6.3.3
.1.3.6.1.4.1.5454.1.80.5.6.3.4
.1.3.6.1.4.1.5454.1.80.5.6.3.5
.1.3.6.1.4.1.5454.1.80.5.6.3.6
.1.3.6.1.4.1.5454.1.80.5.6.3.7
.1.3.6.1.4.1.5454.1.80.5.6.3.8
tdmPort6CableConfig
tdmPort6CounterCrcBlockErrors
tdmPort6CounterExCrcErrors
tdmPort6CounterFBAErrors
tdmPort6CounterFEBErrors
tdmPort6CounterLCViolations
tdmPort6EventLOS
tdmPort6EventLOF
tdmPort6EventAIS
tdmPort6EventTS16AIS
tdmPort6EventRAI
tdmPort6EventRMA
tdmPort6EventLCMFA
tdmPort6EventLSMFA
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
200
TDMSection,Contd
.1.3.6.1.4.1.5454.1.80.5.7.1.1
tdmPort7Status
.1.3.6.1.4.1.5454.1.80.5.7.1.2
.1.3.6.1.4.1.5454.1.80.5.7.2.1
.1.3.6.1.4.1.5454.1.80.5.7.2.2
.1.3.6.1.4.1.5454.1.80.5.7.2.3
.1.3.6.1.4.1.5454.1.80.5.7.2.4
.1.3.6.1.4.1.5454.1.80.5.7.2.5
.1.3.6.1.4.1.5454.1.80.5.7.3.1
.1.3.6.1.4.1.5454.1.80.5.7.3.2
.1.3.6.1.4.1.5454.1.80.5.7.3.3
.1.3.6.1.4.1.5454.1.80.5.7.3.4
.1.3.6.1.4.1.5454.1.80.5.7.3.5
.1.3.6.1.4.1.5454.1.80.5.7.3.6
.1.3.6.1.4.1.5454.1.80.5.7.3.7
.1.3.6.1.4.1.5454.1.80.5.7.3.8
.1.3.6.1.4.1.5454.1.80.5.8.1.1
.1.3.6.1.4.1.5454.1.80.5.8.1.2
.1.3.6.1.4.1.5454.1.80.5.8.2.1
.1.3.6.1.4.1.5454.1.80.5.8.2.2
.1.3.6.1.4.1.5454.1.80.5.8.2.3
.1.3.6.1.4.1.5454.1.80.5.8.2.4
.1.3.6.1.4.1.5454.1.80.5.8.2.5
.1.3.6.1.4.1.5454.1.80.5.8.3.1
.1.3.6.1.4.1.5454.1.80.5.8.3.2
.1.3.6.1.4.1.5454.1.80.5.8.3.3
.1.3.6.1.4.1.5454.1.80.5.8.3.4
.1.3.6.1.4.1.5454.1.80.5.8.3.5
.1.3.6.1.4.1.5454.1.80.5.8.3.6
.1.3.6.1.4.1.5454.1.80.5.8.3.7
.1.3.6.1.4.1.5454.1.80.5.8.3.8
TrangoSystems,Inc.
Integer
RO
0(Off), 1(On)
0(Off)
tdmPort7CableConfig
tdmPort7CounterCrcBlockErrors
tdmPort7CounterExCrcErrors
tdmPort7CounterFBAErrors
tdmPort7CounterFEBErrors
tdmPort7CounterLCViolations
tdmPort7EventLOS
tdmPort7EventLOF
tdmPort7EventAIS
tdmPort7EventTS16AIS
tdmPort7EventRAI
tdmPort7EventRMA
tdmPort7EventLCMFA
tdmPort7EventLSMFA
tdmPort8Status
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)
tdmPort8CableConfig
tdmPort8CounterCrcBlockErrors
tdmPort8CounterExCrcErrors
tdmPort8CounterFBAErrors
tdmPort8CounterFEBErrors
tdmPort8CounterLCViolations
tdmPort8EventLOS
tdmPort8EventLOF
tdmPort8EventAIS
tdmPort8EventTS16AIS
tdmPort8EventRAI
tdmPort8EventRMA
tdmPort8EventLCMFA
tdmPort8EventLSMFA
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GigaPlusUserManualRev1.3
201
Traps
Object ID
.1.3.6.1.4.1.5454.1.80.6.1
.1.3.6.1.4.1.5454.1.80.6.2.1
.1.3.6.1.4.1.5454.1.80.6.2.2
.1.3.6.1.4.1.5454.1.80.6.2.3
.1.3.6.1.4.1.5454.1.80.6.3.1
.1.3.6.1.4.1.5454.1.80.6.3.2
.1.3.6.1.4.1.5454.1.80.6.4.1
.1.3.6.1.4.1.5454.1.80.6.4.2
.1.3.6.1.4.1.5454.1.80.6.4.3
.1.3.6.1.4.1.5454.1.80.6.4.4
.1.3.6.1.4.1.5454.1.80.6.5.1
Name
trapStartUp
trapReboot
trapIPReset
trapConfigReset
trapRPSPortUp
trapRPSPortDown
trapEth1StatusUpdate
trapEth2StatusUpdate
trapEth3StatusUpdate
trapEth4StatusUpdate
trapLinkLock
.1.3.6.1.4.1.5454.1.80.6.5.2
trapACMTxProfileChange
RO
.1.3.6.1.4.1.5454.1.80.6.5.3
.1.3.6.1.4.1.5454.1.80.6.6.1
.1.3.6.1.4.1.5454.1.80.6.6.2
.1.3.6.1.4.1.5454.1.80.6.6.3
.1.3.6.1.4.1.5454.1.80.6.6.4
.1.3.6.1.4.1.5454.1.80.6.6.5
.1.3.6.1.4.1.5454.1.80.6.6.6
.1.3.6.1.4.1.5454.1.80.6.6.7
.1.3.6.1.4.1.5454.1.80.6.6.8
.1.3.6.1.4.1.5454.1.80.6.6.9
.1.3.6.1.4.1.5454.1.80.6.6.10
.1.3.6.1.4.1.5454.1.80.6.6.11
.1.3.6.1.4.1.5454.1.80.6.6.12
.1.3.6.1.4.1.5454.1.80.6.6.13
.1.3.6.1.4.1.5454.1.80.6.6.14
.1.3.6.1.4.1.5454.1.80.6.6.15
.1.3.6.1.4.1.5454.1.80.6.6.16
.1.3.6.1.4.1.5454.1.80.6.7.1
.1.3.6.1.4.1.5454.1.80.6.7.2
.1.3.6.1.4.1.5454.1.80.6.7.3
.1.3.6.1.4.1.5454.1.80.6.7.4
.1.3.6.1.4.1.5454.1.80.6.8.1
.1.3.6.1.4.1.5454.1.80.6.8.2
.1.3.6.1.4.1.5454.1.80.6.8.3
.1.3.6.1.4.1.5454.1.80.6.8.4
.1.3.6.1.4.1.5454.1.80.6.8.5
.1.3.6.1.4.1.5454.1.80.6.8.6
.1.3.6.1.4.1.5454.1.80.6.8.7
.1.3.6.1.4.1.5454.1.80.6.8.8
.1.3.6.1.4.1.5454.1.80.6.9.1
.1.3.6.1.4.1.5454.1.80.6.9.2
.1.3.6.1.4.1.5454.1.80.6.10.1
.1.3.6.1.4.1.5454.1.80.6.10.2
.1.3.6.1.4.1.5454.1.80.6.11
.1.3.6.1.4.1.5454.1.80.6.12.1
.1.3.6.1.4.1.5454.1.80.6.12.2
.1.3.6.1.4.1.5454.1.80.6.12.3
.1.3.6.1.4.1.5454.1.80.6.12.4
.1.3.6.1.4.1.5454.1.80.6.12.5
.1.3.6.1.4.1.5454.1.80.6.12.6
trapACMRxProfileChange
trapIDUTempMinThreshold
trapIDUTempMaxThreshold
trapODUTempMinThreshold
trapODUTempMaxThreshold
trapMSEMinThreshold
trapMSEMaxThreshold
trapBERMinThreshold
trapBERMaxThreshold
trapFERMinThreshold
trapFERMaxThreshold
trapRSSIMinThreshold
trapRSSIMaxThreshold
trapInPortUtilMinThreshold
trapInPortUtilMaxThreshold
trapOutPortUtilMinThreshold
trapOutPortUtilMaxThreshold
trapVoltage1.25Failure
trapVoltage2.5Failure
trapVoltage3.3Failure
trapVoltage5Failure
trapTDM1StatusUpdate
trapTDM2StatusUpdate
trapTDM3StatusUpdate
trapTDM4StatusUpdate
trapTDM5StatusUpdate
trapTDM6StatusUpdate
trapTDM7StatusUpdate
trapTDM8StatusUpdate
trapManualSwitchover
trapHWSwitchover
trapRedundancyCableRemoved
trapRedundancyCableReconnected
trapLostODUCommunication
trapUtypeActiveElected
trapUtypeStandbyElected
trapActiveDetected
trapStandbyDetected
trapActiveDown
trapStandbyDown
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
.1.3.6.1.4.1.5454.1.80.6.13
trapSynchronization
RO
TrangoSystems,Inc.
Access
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Range Limit
N/A
N/A
Default Value
N/A
N/A
N/A
N/A
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(NORMAL), 1(LOCKED)
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
Current IDU Temp
Current IDU Temp
Current ODU Temp
Current ODU Temp
Current MSE value
Current MSE value
Current BER value
Current BER value
Current FER value
Current FER value
Current RSSI value
Current RSSI value
Current In port untilization
Current In port untilization
Current Out port untilization
Current Out port untilization
1(Failed)
1(Failed)
1(Failed)
1(Failed)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
1(Active), 2(Standby)
1(Active), 2(Standby)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Not Synchronized),
1(Synchronized)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GigaPlusUserManualRev1.3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
202
AppendixEPartNumbers
GigaPlusHPODUSubbands/TuningRanges
Outdoor Unit
Part Numbers
Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)
Description
HP ODUs, 6 GHZ
HP2-06-0160-1A
HP2-06-0160-1B
HP2-06-0160-2A
HP2-06-0160-2B
HP2-06-0160-3A
HP2-06-0160-3B
HP2-06-0160-4A
HP2-06-0160-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
1A
1B
2A
2B
3A
3B
4A
4B
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
6,540
6,700
6,580
6,740
6,620
6,780
6,660
6,820
6,600
6,760
6,640
6,800
6,680
6,840
6,710
6,870
60
60
60
60
60
60
50
50
56
56
56
56
56
56
50
50
HP2-06-0170-1A
HP2-06-0170-1B
HP2-06-0170-2A
HP2-06-0170-2B
HP2-06-0170-3A
HP2-06-0170-3B
HP2-06-0170-4A
HP2-06-0170-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
1A
1B
2A
2B
3A
3B
4A
4B
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
6,540
6,710
6,580
6,750
6,620
6,790
6,660
6,830
6,590
6,760
6,630
6,800
6,670
6,840
6,700
6,870
50
50
50
50
50
50
40
40
50
50
50
50
50
50
40
40
HP-06-0240-1A
HP-06-0240-1B
HP-06-0240-2A
HP-06-0240-2B
HP-06-0240-3A
HP-06-0240-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
5,925
6,175
6,000
6,250
6,075
6,325
6,025
6,275
6,100
6,350
6,175
6,425
100
100
100
100
100
100
56
56
56
56
56
56
HP2-06-0252-1A
HP2-06-0252-1B
HP2-06-0252-2A
HP2-06-0252-2B
HP2-06-0252-3A
HP2-06-0252-3B
HP2-06-0252-4A
HP2-06-0252-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
5,915.55
6,167.59
5,974.85
6,226.89
6,034.15
6,286.19
6,093.45
6,345.49
5,989.68
6,241.72
6,048.98
6,301.02
6,108.28
6,360.32
6,167.58
6,419.62
74
74
74
74
74
74
74
74
56
56
56
56
56
56
56
56
HP-06-0252-1A
HP-06-0252-1B
HP-06-0252-2A
HP-06-0252-2B
HP-06-0252-3A
HP-06-0252-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
5,925
6,175
6,000
6,250
6,075
6,325
6,025
6,275
6,100
6,350
6,175
6,425
100
100
100
100
100
100
56
56
56
56
56
56
HP2-06-0300-1A
HP2-06-0300-1B
HP2-06-0300-2A
HP2-06-0300-2B
HP2-06-0300-3A
HP2-06-0300-3B
HP2-06-0300-4A
HP2-06-0300-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
5,850
6,150
5,918
6,218
5,986
6,286
6,054
6,354
5,946
6,246
6,014
6,314
6,082
6,382
6,150
6,450
96
96
96
96
96
96
96
96
56
56
56
56
56
56
56
56
TrangoSystems,Inc.
6Ghz,ETSI TR240, 1A
6Ghz, ETSI TR240, 1B
6Ghz, ETSI TR240, 2A
6Ghz, ETSI TR240, 2B
6Ghz, ETSI TR240, 3A
6Ghz, ETSI TR240, 3B
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
1A
1B
2A
2B
3A
3B
4A
4B
1A
1B
2A
2B
3A
3B
4A
4B
1A
1B
2A
2B
3A
3B
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
GigaPlusUserManualRev1.3
203
Outdoor Unit
Part Numbers
Description
HP2-06-0340-1A
HP2-06-0340-1B
HP2-06-0340-2A
HP2-06-0340-2B
HP2-06-0340-3A
HP2-06-0340-3B
HP2-06-0340-4A
HP2-06-0340-4B
HP2-06-0340-5A
HP2-06-0340-5B
HP2-06-0340-6A
HP2-06-0340-6B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP-06-0340-1A
HP-06-0340-1B
HP-06-0340-2A
HP-06-0340-2B
HP-06-0340-3A
HP-06-0340-3B
HP-06-0340-4A
HP-06-0340-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
HP2-06-0350-1A
HP2-06-0350-1B
HP2-06-0350-2A
HP2-06-0350-2B
HP2-06-0350-3A
HP2-06-0350-3B
HP2-06-0350-4A
HP2-06-0350-4B
HP2-06-0350-5A
HP2-06-0350-5B
HP2-06-0350-6A
HP2-06-0350-6B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
TrangoSystems,Inc.
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
1A
1B
2A
2B
3A
3B
4A
4B
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)
6,425
6,765
6,481
6,821
6,536
6,876
6,591
6,931
6,646
6,986
6,701
7,041
6,509
6,849
6,564
6,904
6,619
6,959
6,674
7,014
6,729
7,069
6,785
7,125
84
84
83
83
83
83
83
83
83
83
84
84
56
56
56
56
56
56
56
56
56
56
56
56
6,430
6,770
6,520
6,860
6,600
6,940
6,670
7,010
6,540
6,880
6,630
6,970
6,710
7,050
6,780
7,120
110
110
110
110
110
110
110
110
56
56
56
56
56
56
56
56
6,425
6,775
6,481
6,831
6,536
6,886
6,591
6,941
6,646
6,996
6,701
7,051
6,499
6,849
6,554
6,904
6,609
6,959
6,664
7,014
6,719
7,069
6,775
7,125
74
74
73
73
73
73
73
73
73
73
74
74
56
56
56
56
56
56
56
56
56
56
56
56
GigaPlusUserManualRev1.3
204
Outdoor Unit
Part Numbers
Description
Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)
HP ODUs, 7 GHZ
HP2-07-0154-1A
HP2-07-0154-1B
HP2-07-0154-2A
HP2-07-0154-2B
HP2-07-0154-3A
HP2-07-0154-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP-07-0154-1A
HP-07-0154-1B
HP-07-0154-2A
HP-07-0154-2B
HP-07-0154-3A
HP-07-0154-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP2-07-0160-1A
HP2-07-0160-1B
HP2-07-0160-2A
HP2-07-0160-2B
HP2-07-0160-3A
HP2-07-0160-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP-07-0160-1A
HP-07-0160-1B
HP-07-0160-2A
HP-07-0160-2B
HP-07-0160-3A
HP-07-0160-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP2-07-0161-1A
HP2-07-0161-1B
HP2-07-0161-2A
HP2-07-0161-2B
HP2-07-0161-3A
HP2-07-0161-3B
HP2-07-0161-4A
HP2-07-0161-4B
HP2-07-0161-5A
HP2-07-0161-5B
HP2-07-0161-6A
HP2-07-0161-6B
HP2-07-0161-7A
HP2-07-0161-7B
HP2-07-0161-8A
HP2-07-0161-8B
HP2-07-0161-9A
HP2-07-0161-9B
HP2-07-0161-10A
HP2-07-0161-10B
HP2-07-0161-21A
HP2-07-0161-21B
HP2-07-0161-22A
HP2-07-0161-22B
HP2-07-0161-23A
HP2-07-0161-23B
HP2-07-0161-24A
HP2-07-0161-24B
HP2-07-0161-25A
HP2-07-0161-25B
HP2-07-0161-26A
HP2-07-0161-26B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
TrangoSystems,Inc.
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
1A
1B
2A
2B
3A
3B
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
1A
1B
2A
2B
3A
3B
1A
1B
2A
2B
3A
3B
1A
1B
2A
2B
3A
3B
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
21A
21B
22A
22B
23A
23B
24A
24B
25A
25B
26A
26B
7,428
7,582
7,470
7,624
7,512
7,666
7,484
7,638
7,526
7,680
7,568
7,722
56
56
56
56
56
56
56
56
56
56
56
56
7,428
7,582
7,470
7,624
7,512
7,666
7,484
7,638
7,526
7,680
7,568
7,722
56
56
56
56
56
56
56
56
56
56
56
56
7,434
7,594
7,479
7,639
7,526
7,686
7,497
7,657
7,542
7,702
7,589
7,749
63
63
63
63
63
63
56
56
56
56
56
56
7,433.5
7,593.5
7,478.5
7,638.5
7,526.0
7,686.0
7,496.5
7,656.5
7,541.5
7,701.5
7,589.0
7,749.0
63
63
63
63
63
63
56
56
56
56
56
56
7,114
7,275
7,149
7,310
7,184
7,345
7,219
7,380
7,239
7,400
7,274
7,435
7,309
7,470
7,344
7,505
7,414
7,575
7,449
7,610
7,484
7,645
7,519
7,680
7,539
7,700
7,574
7,735
7,609
7,770
7,644
7,805
7,177
7,338
7,212
7,373
7,247
7,408
7,282
7,443
7,302
7,463
7,337
7,498
7,372
7,533
7,407
7,568
7,477
7,638
7,512
7,673
7,547
7,708
7,582
7,743
7,602
7,763
7,637
7,798
7,672
7,833
7,707
7,868
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
GigaPlusUserManualRev1.3
205
Outdoor Unit
Part Numbers
Description
HP-07-0161-1A
HP-07-0161-1B
HP-07-0161-2A
HP-07-0161-2B
HP-07-0161-3A
HP-07-0161-3B
HP-07-0161-4A
HP-07-0161-4B
HP-07-0161-5A
HP-07-0161-5B
HP-07-0161-6A
HP-07-0161-6B
HP-07-0161-7A
HP-07-0161-7B
HP-07-0161-8A
HP-07-0161-8B
HP-07-0161-9A
HP-07-0161-9B
HP-07-0161-10A
HP-07-0161-10B
HP-07-0161-21A
HP-07-0161-21B
HP-07-0161-22A
HP-07-0161-22B
HP-07-0161-23A
HP-07-0161-23B
HP-07-0161-24A
HP-07-0161-24B
HP-07-0161-25A
HP-07-0161-25B
HP-07-0161-26A
HP-07-0161-26B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP2-07-0168-1A
HP2-07-0168-1B
HP2-07-0168-2A
HP2-07-0168-2B
HP2-07-0168-3A
HP2-07-0168-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP-07-0168-1A
HP-07-0168-1B
HP-07-0168-2A
HP-07-0168-2B
HP-07-0168-3A
HP-07-0168-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
TrangoSystems,Inc.
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
21A
21B
22A
22B
23A
23B
24A
24B
25A
25B
26A
26B
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
1A
1B
2A
2B
3A
3B
1A
1B
2A
2B
3A
3B
Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)
7,114
7,275
7,149
7,310
7,184
7,345
7,219
7,380
7,239
7,400
7,274
7,435
7,309
7,470
7,344
7,505
7,414
7,575
7,449
7,610
7,484
7,645
7,519
7,680
7,539
7,700
7,574
7,735
7,609
7,770
7,644
7,805
7,177
7,338
7,212
7,373
7,247
7,408
7,282
7,443
7,302
7,463
7,337
7,498
7,372
7,533
7,407
7,568
7,477
7,638
7,512
7,673
7,547
7,708
7,582
7,743
7,602
7,763
7,637
7,798
7,672
7,833
7,707
7,868
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
7,443
7,611
7,485
7,653
7,527
7,695
7,499
7,667
7,541
7,709
7,583
7,751
56
56
56
56
56
56
56
56
56
56
56
56
7,443
7,611
7,485
7,653
7,527
7,695
7,499
7,667
7,541
7,709
7,583
7,751
56
56
56
56
56
56
56
56
56
56
56
56
GigaPlusUserManualRev1.3
206
Outdoor Unit
Part Numbers
Description
HP2-07-0196-1A
HP2-07-0196-1B
HP2-07-0196-2A
HP2-07-0196-2B
HP2-07-0196-3A
HP2-07-0196-3B
HP2-07-0196-4A
HP2-07-0196-4B
HP2-07-0196-5A
HP2-07-0196-5B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP-07-0196-1A
HP-07-0196-1B
HP-07-0196-2A
HP-07-0196-2B
HP-07-0196-3A
HP-07-0196-3B
HP-07-0196-4A
HP-07-0196-4B
HP-07-0196-5A
HP-07-0196-5B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP2-07-0245-1A
HP2-07-0245-1B
HP2-07-0245-2A
HP2-07-0245-2B
HP2-07-0245-3A
HP2-07-0245-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP-07-0245-1A
HP-07-0245-1B
HP-07-0245-2A
HP-07-0245-2B
HP-07-0245-3A
HP-07-0245-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
TrangoSystems,Inc.
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
1A
1B
2A
2B
3A
3B
1A
1B
2A
2B
3A
3B
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
7,093
7,289
7,121
7,317
7,149
7,345
7,177
7,373
7,205
7,401
7,149
7,345
7,177
7,373
7,205
7,401
7,233
7,429
7,261
7,457
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
7,093
7,289
7,121
7,317
7,149
7,345
7,177
7,373
7,205
7,401
7,149
7,345
7,177
7,373
7,205
7,401
7,233
7,429
7,261
7,457
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
7,400
7,645
7,484
7,729
7,568
7,813
7,484
7,729
7,568
7,813
7,652
7,897
84
84
84
84
84
84
56
56
56
56
56
56
7,400
7,645
7,484
7,729
7,568
7,813
7,484
7,729
7,568
7,813
7,652
7,897
84
84
84
84
84
84
56
56
56
56
56
56
GigaPlusUserManualRev1.3
207
Outdoor Unit
Part Numbers
Description
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
HP ODUs,- 8 GHZ
HP2-08-0119-1A
HP2-08-0119-1B
HP2-08-0119-2A
HP2-08-0119-2B
HP2-08-0119-3A
HP2-08-0119-3B
HP2-08-0119-4A
HP2-08-0119-4B
HP2-08-0119-5A
HP2-08-0119-5B
HP2-08-0119-6A
HP2-08-0119-6B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP-08-0119-1A
HP-08-0119-1B
HP-08-0119-2A
HP-08-0119-2B
HP-08-0119-3A
HP-08-0119-3B
HP-08-0119-4A
HP-08-0119-4B
HP-08-0119-5A
HP-08-0119-5B
HP-08-0119-6A
HP-08-0119-6B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
HP-08-0151-1A
HP-08-0151-1B
HP-08-0151-2A
HP-08-0151-2B
HP-08-0151-3A
HP-08-0151-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
ETSI TR151,
ETSI TR151,
ETSI TR151,
ETSI TR151,
ETSI TR151,
ETSI TR151,
HP2-08-0208-1A
HP2-08-0208-1B
HP2-08-0208-2A
HP2-08-0208-2B
HP2-08-0208-3A
HP2-08-0208-3B
HP2-08-0208-4A
HP2-08-0208-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP-08-0208-1A
HP-08-0208-1B
HP-08-0208-2A
HP-08-0208-2B
HP-08-0208-3A
HP-08-0208-3B
HP-08-0208-4A
HP-08-0208-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
TrangoSystems,Inc.
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
8,279
8,398
8,293
8,412
8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468
8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468
8,363
8,482
8,377
8,496
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
8,279
8,398
8,293
8,412
8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468
8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468
8,363
8,482
8,377
8,496
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
1A
1B
2A
2B
3A
3B
8,203
8,355
8,240
8,392
8,277
8,429
8,271
8,423
8,308
8,460
8,345
8,497
68
68
68
68
68
68
56
56
56
56
56
56
8,043
8,251
8,099
8,307
8,155
8,363
8,211
8,419
8,113
8,321
8,169
8,377
8,225
8,433
8,281
8,489
70
70
70
70
70
70
70
70
56
56
56
56
56
56
56
56
8,043
8,251
8,099
8,307
8,155
8,363
8,211
8,419
8,113
8,321
8,169
8,377
8,225
8,433
8,281
8,489
70
70
70
70
70
70
70
70
56
56
56
56
56
56
56
56
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
1A
1B
2A
2B
3A
3B
4A
4B
1A
1B
2A
2B
3A
3B
4A
4B
GigaPlusUserManualRev1.3
208
Outdoor Unit
Part Numbers
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
Description
HP2-08-0266-1A
HP2-08-0266-1B
HP2-08-0266-2A
HP2-08-0266-2B
ODU,
ODU,
ODU,
ODU,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP-08-0266-1A
HP-08-0266-1B
HP-08-0266-2A
HP-08-0266-2B
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP2-08-0311-1A
HP2-08-0311-1B
HP2-08-0311-2A
HP2-08-0311-2B
ODU,
ODU,
ODU,
ODU,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP-08-0311-2A
HP-08-0311-2B
HP-08-0311-3A
HP-08-0311-3B
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
1A
1B
2A
2B
ETSI TR311,
ETSI TR311,
ETSI TR311,
ETSI TR311,
ETSI TR311,
ETSI TR311,
ETSI TR311,
ETSI TR311,
1A
1B
2A
2B
1A
1B
2A
2B
2A
2B
3A
3B
7,905
8,171
8,017
8,283
8,024
8,290
8,136
8,402
119
119
119
119
56
56
56
56
7,905
8,171
8,017
8,283
8,024
8,290
8,136
8,402
119
119
119
119
56
56
56
56
7,731
8,042
7,835
8,146
7,867
8,178
7,971
8,282
136
136
136
136
56
56
56
56
7,835
8,146
7,717
8,028
7,971
8,282
7,867
8,178
136
136
150
150
56
56
56
56
10,150
10,500
10,300
10,650
150
150
56
56
10,700
11,200
10,855
11,355
11,010
11,510
10,890
11,390
11,045
11,545
11,200
11,700
190
190
190
190
190
190
56
56
56
56
56
56
10,700
11,200
10,855
11,355
11,010
11,510
10,890
11,390
11,045
11,545
11,200
11,700
190
190
190
190
190
190
56
56
56
56
56
56
10,675
11,205
10,795
11,325
10,915
11,445
11,035
11,565
10,855
11,385
10,975
11,505
11,135
11,665
11,215
11,745
180
180
180
180
220
220
180
180
56
56
56
56
56
56
56
56
10,675
11,205
10,795
11,325
10,915
11,445
11,035
11,565
10,855
11,385
10,975
11,505
11,135
11,665
11,215
11,745
180
180
180
180
220
220
180
180
56
56
56
56
56
56
56
56
HP ODUs,- 10 GHZ
HP2-10-0350-1A
HP2-10-0350-1B
HP ODUs, 11 GHZ
HP2-11-0490-5A
HP2-11-0490-5B
HP2-11-0490-6A
HP2-11-0490-6B
HP2-11-0490-7A
HP2-11-0490-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP-11-0490-5A
HP-11-0490-5B
HP-11-0490-6A
HP-11-0490-6B
HP-11-0490-7A
HP-11-0490-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP2-11-0530-1A
HP2-11-0530-1B
HP2-11-0530-2A
HP2-11-0530-2B
HP2-11-0530-3A
HP2-11-0530-3B
HP2-11-0530-4A
HP2-11-0530-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP-11-0530-1A
HP-11-0530-1B
HP-11-0530-2A
HP-11-0530-2B
HP-11-0530-3A
HP-11-0530-3B
HP-11-0530-4A
HP-11-0530-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
TrangoSystems,Inc.
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
1A
1B
2A
2B
3A
3B
4A
4B
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
5A
5B
6A
6B
7A
7B
GigaPlusUserManualRev1.3
209
Outdoor Unit
Part Numbers
Description
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
HP ODUs, 13 GHZ
HP2-13-0266-1A
HP2-13-0266-1B
HP2-13-0266-2A
HP2-13-0266-2B
HP2-13-0266-3A
HP2-13-0266-3B
HP2-13-0266-4A
HP2-13-0266-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP-13-0266-1A
HP-13-0266-1B
HP-13-0266-2A
HP-13-0266-2B
HP-13-0266-3A
HP-13-0266-3B
HP-13-0266-4A
HP-13-0266-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
1A
1B
2A
2B
3A
3B
4A
4B
1A
1B
2A
2B
3A
3B
4A
4B
12,751
13,017
12,807
13,073
12,863
13,129
12,919
13,185
12,814
13,080
12,870
13,136
12,926
13,192
12,982
13,248
63
63
63
63
63
63
63
63
56
56
56
56
56
56
56
56
12,751
13,017
12,807
13,073
12,863
13,129
12,919
13,185
12,814
13,080
12,870
13,136
12,926
13,192
12,982
13,248
63
63
63
63
63
63
63
63
56
56
56
56
56
56
56
56
14,627
14,942
14,725
15,040
14,823
15,138
14,732
15,047
14,844
15,159
14,928
15,243
105
105
119
119
105
105
56
56
56
56
56
56
14,627
14,942
14,725
15,040
14,823
15,138
14,746
15,061
14,844
15,159
14,942
15,257
119
119
119
119
119
119
56
56
56
56
56
56
14,501
14,921
14,606
15,026
14,718
15,138
14,816
15,236
14,613
15,033
14,725
15,145
14,837
15,257
14,928
15,348
112
112
119
119
119
119
112
112
56
56
56
56
56
56
56
56
14,501
14,921
14,606
15,026
14,718
15,138
14,816
15,236
14,613
15,033
14,725
15,145
14,837
15,257
14,928
15,348
112
112
119
119
119
119
112
112
56
56
56
56
56
56
56
56
HP ODUs, 15 GHZ
HP2-15-0315-1A
HP2-15-0315-1B
HP2-15-0315-2A
HP2-15-0315-2B
HP2-15-0315-3A
HP2-15-0315-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP-15-0315-1A
HP-15-0315-1B
HP-15-0315-2A
HP-15-0315-2B
HP-15-0315-3A
HP-15-0315-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP2-15-0420-4A
HP2-15-0420-4B
HP2-15-0420-5A
HP2-15-0420-5B
HP2-15-0420-6A
HP2-15-0420-6B
HP2-15-0420-7A
HP2-15-0420-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP-15-0420-4A
HP-15-0420-4B
HP-15-0420-5A
HP-15-0420-5B
HP-15-0420-6A
HP-15-0420-6B
HP-15-0420-7A
HP-15-0420-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
TrangoSystems,Inc.
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
1A
1B
2A
2B
3A
3B
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
4A
4B
5A
5B
6A
6B
7A
7B
GigaPlusUserManualRev1.3
210
Outdoor Unit
Part Numbers
Description
HP2-15-0490-4A
HP2-15-0490-4B
HP2-15-0490-5A
HP2-15-0490-5B
HP2-15-0490-6A
HP2-15-0490-6B
HP2-15-0490-7A
HP2-15-0490-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP-15-0490-4A
HP-15-0490-4B
HP-15-0490-5A
HP-15-0490-5B
HP-15-0490-6A
HP-15-0490-6B
HP-15-0490-7A
HP-15-0490-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
HP2-15-0475-1A
HP2-15-0475-1B
HP2-15-0475-2A
HP2-15-0475-2B
HP2-15-0475-3A
HP2-15-0475-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP-15-0475-1A
HP-15-0475-1B
HP-15-0475-2A
HP-15-0475-2B
HP-15-0475-3A
HP-15-0475-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP2-15-0640-1A
HP2-15-0640-1B
HP2-15-0640-2A
HP2-15-0640-2B
ODU,
ODU,
ODU,
ODU,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP-15-0640-1A
HP-15-0640-1B
HP-15-0640-2A
HP-15-0640-2B
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP2-15-0644-1A
HP2-15-0644-1B
HP2-15-0644-2A
HP2-15-0644-2B
HP2-15-0644-3A
HP2-15-0644-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP-15-0644-1A
HP-15-0644-1B
HP-15-0644-2A
HP-15-0644-2B
HP-15-0644-3A
HP-15-0644-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
TrangoSystems,Inc.
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
4A
4B
5A
5B
6A
6B
7A
7B
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
1A
1B
2A
2B
1A
1B
2A
2B
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
1A
1B
2A
2B
3A
3B
1A
1B
2A
2B
3A
3B
ETSI TR640,
ETSI TR640,
ETSI TR640,
ETSI TR640,
ETSI TR640,
ETSI TR640,
ETSI TR640,
ETSI TR640,
4A
4B
5A
5B
6A
6B
7A
7B
1A
1B
2A
2B
3A
3B
1A
1B
2A
2B
3A
3B
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
14,403
14,893
14,515
15,005
14,627
15,117
14,739
15,229
14,522
15,012
14,634
15,124
14,746
15,236
14,858
15,348
119
119
119
119
119
119
119
119
56
56
56
56
56
56
56
56
14,403
14,893
14,515
15,005
14,627
15,117
14,739
15,229
14,522
15,012
14,634
15,124
14,746
15,236
14,858
15,348
119
119
119
119
119
119
119
119
56
56
56
56
56
56
56
56
14,500
14,975
14,660
15,135
14,715
15,190
14,668
15,143
14,828
15,303
14,883
15,358
168
168
168
168
168
168
56
56
56
56
56
56
14,500
14,975
14,660
15,135
14,783
15,258
14,668
15,143
14,828
15,303
14,883
15,358
168
168
168
168
100
100
56
56
56
56
56
56
14,500
15,140
14,605
15,245
14,610
15,250
14,715
15,355
110
110
110
110
56
56
56
56
14,500
15,140
14,605
15,245
14,610
15,250
14,715
15,355
110
110
110
110
56
56
56
56
14,400
15,044
14,498
15,142
14,596
15,240
14,512
15,156
14,610
15,254
14,708
15,352
112
112
112
112
112
112
56
56
56
56
56
56
14,400
15,044
14,498
15,142
14,596
15,240
14,512
15,156
14,610
15,254
14,708
15,352
112
112
112
112
112
112
56
56
56
56
56
56
GigaPlusUserManualRev1.3
211
Outdoor Unit
Part Numbers
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
Description
HP-15-0728-1A
HP-15-0728-1B
HP-15-0728-2A
HP-15-0728-2B
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
15Ghz,
15Ghz,
15Ghz,
15Ghz,
ETSI TR728,
ETSI TR728,
ETSI TR728,
ETSI TR728,
1A
1B
2A
2B
HP2-15-0728-1A
HP2-15-0728-1B
14,500
15,228
14,500
15,228
14,615
15,343
14,625
15,353
115
115
125
125
56
56
56
56
14,500
15,228
14,615
15,343
115
115
56
56
17,685
18,695
17,930
18,940
18,180
19,190
18,400
19,410
17,985
18,995
18,230
19,240
18,480
19,490
18,700
19,710
300
300
300
300
300
300
300
300
56
56
56
56
56
56
56
56
17,685
18,695
17,930
18,940
18,180
19,190
18,400
19,410
17,985
18,995
18,230
19,240
18,480
19,490
18,700
19,710
300
300
300
300
300
300
300
300
56
56
56
56
56
56
56
56
17,700
18,805
17,975
19,080
18,235
19,340
18,060
19,165
18,335
19,440
18,595
19,700
360
360
360
360
360
360
56
56
56
56
56
56
HP ODUs, 18 GHZ
HP2-18-1010-1A
HP2-18-1010-1B
HP2-18-1010-2A
HP2-18-1010-2B
HP2-18-1010-3A
HP2-18-1010-3B
HP2-18-1010-4A
HP2-18-1010-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP-18-1010-1A
HP-18-1010-1B
HP-18-1010-2A
HP-18-1010-2B
HP-18-1010-3A
HP-18-1010-3B
HP-18-1010-4A
HP-18-1010-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
HP-18-1092-1A
HP-18-1092-1B
HP-18-1092-2A
HP-18-1092-2B
HP-18-1092-3A
HP-18-1092-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
ETSI TR1092,
ETSI TR1092,
ETSI TR1092,
ETSI TR1092,
ETSI TR1092,
ETSI TR1092,
HP2-18-1560-3A
HP2-18-1560-3B
17,700
19,260
18,140
19,700
440
440
56
56
HP-18-1560-3A
HP-18-1560-3B
17,700
19,260
18,140
19,700
440
440
56
56
TrangoSystems,Inc.
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
1A
1B
2A
2B
3A
3B
1A
1B
2A
2B
3A
3B
4A
4B
1A
1B
2A
2B
3A
3B
4A
4B
GigaPlusUserManualRev1.3
212
Outdoor Unit
Part Numbers
Description
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
HP ODUs, 23 GHZ
HP2-23-1008-1A
HP2-23-1008-1B
HP2-23-1008-2A
HP2-23-1008-2B
ODU,
ODU,
ODU,
ODU,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP-23-1008-1A
HP-23-1008-1B
HP-23-1008-2A
HP-23-1008-2B
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP2-23-1200-5A
HP2-23-1200-5B
HP2-23-1200-6A
HP2-23-1200-6B
HP2-23-1200-7A
HP2-23-1200-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP-23-1200-5A
HP-23-1200-5B
HP-23-1200-6A
HP-23-1200-6B
HP-23-1200-7A
HP-23-1200-7B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP2-23-1232-1A
HP2-23-1232-1B
HP2-23-1232-2A
HP2-23-1232-2B
HP2-23-1232-3A
HP2-23-1232-3B
HP2-23-1232-4A
HP2-23-1232-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP-23-1232-1A
HP-23-1232-1B
HP-23-1232-2A
HP-23-1232-2B
HP-23-1232-3A
HP-23-1232-3B
HP-23-1232-4A
HP-23-1232-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
TrangoSystems,Inc.
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
1A
1B
2A
2B
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
5A
5B
6A
6B
7A
7B
5A
5B
6A
6B
7A
7B
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
1A
1B
2A
2B
1A
1B
2A
2B
3A
3B
4A
4B
1A
1B
2A
2B
3A
3B
4A
4B
22,000
23,008
22,286
23,294
22,314
23,322
22,600
23,608
314
314
314
314
56
56
56
56
21,994
23,002
22,274
23,282
22,330
23,338
22,610
23,618
336
336
336
336
56
56
56
56
21,200
22,400
21,600
22,800
22,000
23,200
21,600
22,800
22,000
23,200
22,400
23,600
400
400
400
400
400
400
56
56
56
56
56
56
21,200
22,400
21,600
22,800
22,000
23,200
21,600
22,800
22,000
23,200
22,400
23,600
400
400
400
400
400
400
56
56
56
56
56
56
21,200
22,432
21,472
22,704
21,779
23,011
22,086
23,318
21,500
22,732
21,786
23,018
22,093
23,325
22,386
23,618
300
300
314
314
314
314
300
300
56
56
56
56
56
56
56
56
21,200
22,432
21,472
22,704
21,779
23,011
22,086
23,318
21,500
22,732
21,786
23,018
22,093
23,325
22,386
23,618
300
300
314
314
314
314
300
300
56
56
56
56
56
56
56
56
GigaPlusUserManualRev1.3
213
Outdoor Unit
Part Numbers
Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
Description
HP ODUs, 26 GHZ
HP2-26-0800-1A
HP2-26-0800-1B
24,250
25,050
24,450
25,250
200
200
56
56
HP-26-0800-1A
HP-26-0800-1B
24,250
25,050
24,450
25,250
200
200
56
56
HP2-26-1008-1A
HP2-26-1008-1B
HP2-26-1008-2A
HP2-26-1008-2B
HP2-26-1008-3A
HP2-26-1008-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,
24,549
25,557
24,843
25,851
25,123
26,131
24,871
25,879
25,151
26,159
25,445
26,453
322
322
308
308
322
322
56
56
56
56
56
56
HP-26-1008-1A
HP-26-1008-1B
HP-26-1008-2A
HP-26-1008-2B
HP-26-1008-3A
HP-26-1008-3B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
1A
1B
2A
2B
3A
3B
24,549
25,557
24,829
25,837
25,109
26,117
24,885
25,893
25,165
26,173
25,445
26,453
336
336
336
336
336
336
56
56
56
56
56
56
1A
1B
2A
2B
27,520
28,528
27,968
28,976
28,025
29,033
28,473
29,481
505
505
505
505
56
56
56
56
31,815
32,627
32,179
32,991
32,207
33,019
32,571
33,383
392
392
392
392
56
56
56
56
38,595
39,295
38,795
39,495
38,995
39,695
39,195
39,895
38,805
39,505
39,005
39,705
39,205
39,905
39,405
40,105
210
210
210
210
210
210
210
210
56
56
56
56
56
56
56
56
26Ghz,
26Ghz,
26Ghz,
26Ghz,
26Ghz,
26Ghz,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
1A
1B
2A
2B
3A
3B
HP ODUs, 28 GHZ
HP-28-1008-1A
HP-28-1008-1B
HP-28-1008-2A
HP-28-1008-2B
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
28Ghz,
28Ghz,
28Ghz,
28Ghz,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
HP ODUs, 32 GHZ
HP-32-0812-1A
HP-32-0812-1B
HP-32-0812-2A
HP-32-0812-2B
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
32Ghz,
32Ghz,
32Ghz,
32Ghz,
ETSI TR812,
ETSI TR812,
ETSI TR812,
ETSI TR812,
1A
1B
2A
2B
HP ODUs 38 GHZ
HP-38-0700-1A
HP-38-0700-1B
HP-38-0700-2A
HP-38-0700-2B
HP-38-0700-3A
HP-38-0700-3B
HP-38-0700-4A
HP-38-0700-4B
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
HP
HP
HP
HP
HP
HP
HP
HP
38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
1A
1B
2A
2B
3A
3B
4A
4B
HP2-38-1260-1A
37,044
37,632
588
56
HP2-38-1260-1B
38,304
38,892
588
56
HP2-38-1260-2A
37,604
38,192
588
56
HP2-38-1260-2B
38,864
39,452
588
56
HP-38-1260-1A
HP-38-1260-1B
HP-38-1260-2A
HP-38-1260-2B
ODU,
ODU,
ODU,
ODU,
37,044
38,304
37,604
38,864
37,632
38,892
38,192
39,452
588
588
588
588
56
56
56
56
HP
HP
HP
HP
38Ghz,
38Ghz,
38Ghz,
38Ghz,
ANSI/ETSI TR1260,
ANSI/ETSI TR1260,
ANSI/ETSI TR1260,
ANSI/ETSI TR1260,
1A
1B
2A
2B
* Frequencies shown are NOT center frequencies, but rather the edge of the transmit band.
Center frequency limits are 1/2 the channel bandwidth away from these numbers.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
214
Accessories
TRANGO PtP MICROWAVE BAND SPECIFIC ACCESSORIES
Model
Antenna
3/3 dB Dir
Mnt Comb
1.9/6 dB Dir
Mnt Comb
Dir Mnt
Ortho
Comb
Remote Mount
HP ODUs - 6 GHZ
HP-06-0240-xx
AD6GL-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP
HP-06-0252-xx
AD6GL-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP
HP-06-0340-xx
AD6GU-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP
HP2-06-0160-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0170-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0252-xx
AD6GL-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0300-xx
AD6GL-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0340-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0350-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
Note: All -R3 Antennas require a Remote Mount for the ODU and Waveguide
HP-MNT-06-WR137
HP-MNT-06-WR137
HP-MNT-06-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
HP ODUs - 7 GHZ
HP-07-xxxx-xx
HP2-07-xxxx-xx
AD7G-xx-S2
AD7G-xx-S2
SMC-78-3-HP
SMC-78-3-HP
SMC-78-6-HP
SMC-78-6-HP
OMC-07-HP
OMC-07-HP
HP-MNT-78-WR112 SMC-78-3-HP-R
HP-MNT-78-WR112 SMC-78-3-HP-R
SMC-78-6-HP-R
SMC-78-6-HP-R
SMC-78-3-HP
SMC-78-3-HP
SMC-78-6-HP
SMC-78-6-HP
OMC-07-HP
OMC-07-HP
HP-MNT-78-WR112 SMC-78-3-HP-R
HP-MNT-78-WR112 SMC-78-3-HP-R
SMC-78-6-HP-R
SMC-78-6-HP-R
HP ODUs - 8 GHZ
HP-08-xxxx-xx
HP2-08-xxxx-xx
AD8G-xx-R2
AD8G-xx-R2
HP ODUs - 10 GHZ
HP2-10-xxxx-xx
AD10G-xx-S2
NA
NA
NA
NA
NA
NA
HP ODUs - 11 GHZ
HP-11-xxxx-xx
HP2-11-xxxx-xx
AD11G-xx-S2, -R2
AD11G-xx-S2, -R2
SMC-11-3-HP
SMC-11-3-HP
SMC-11-6-HP
SMC-11-6-HP
OMC-11-HP
OMC-11-HP
HP-MNT-11-WR75
HP-MNT-11-WR75
SMC-11-3-HP-R
SMC-11-3-HP-R
SMC-11-6-HP-R
SMC-11-6-HP-R
SMC-13-3-HP
SMC-13-3-HP
SMC-13-6-HP
SMC-13-6-HP
OMC-13-HP
OMC-13-HP
HP-MNT-13-WR75
HP-MNT-13-WR75
SMC-13-3-HP-R
SMC-13-3-HP-R
SMC-13-6-HP-R
SMC-13-6-HP-R
SMC-15-3-HP
SMC-15-3-HP
SMC-15-6-HP
SMC-15-6-HP
OMC-15-HP
OMC-15-HP
HP-MNT-15-WR62
HP-MNT-15-WR62
SMC-15-3-HP-R
SMC-15-3-HP-R
SMC-15-6-HP-R
SMC-15-6-HP-R
SMC-18-3-HP
SMC-18-3-HP
SMC-18-6-HP
SMC-18-6-HP
OMC-18-HP
OMC-18-HP
HP-MNT-18-WR42
HP-MNT-18-WR42
SMC-18-3-HP-R
SMC-18-3-HP-R
SMC-18-6-HP-R
SMC-18-6-HP-R
SMC-23-3-HP
SMC-23-3-HP
SMC-23-6-HP
SMC-23-6-HP
OMC-23-HP
OMC-23-HP
HP-MNT-23-WR42
HP-MNT-23-WR42
SMC-23-6-HP-R
SMC-23-6-HP-R
SMC-26-3-HP-R
SMC-26-3-HP-R
SMC-26-3-HP
SMC-26-3-HP
SMC-26-6-HP
SMC-26-6-HP
NA
NA
HP-MNT-26-WR42
HP-MNT-26-WR42
SMC-26-3-HP-R
SMC-26-3-HP-R
SMC-26-6-HP-R
SMC-26-6-HP-R
SMC-28-3-HP
SMC-28-6-HP
NA
HP-MNT-28-WR28
SMC-28-3-HP-R
SMC-28-6-HP-R
SMC-32-3-HP
SMC-32-6-HP
NA
HP-MNT-32-WR28
SMC-32-3-HP-R
SMC-32-6-HP-R
SMC-38-3-HP
SMC-38-3-HP
SMC-38-3-HP
SMC-38-6-HP
SMC-38-6-HP
SMC-38-6-HP
HP-MNT-38-WR28
HP-MNT-38-WR28
HP-MNT-38-WR28
SMC-38-3-HP-R
SMC-38-3-HP-R
SMC-38-3-HP-R
SMC-38-6-HP-R
SMC-38-6-HP-R
SMC-38-6-HP-R
HP ODUs - 13 GHZ
HP-13-xxxx-xx
HP2-13-xxxx-xx
AD13G-xx-S2, -R2
AD13G-xx-S2, -R2
HP ODUs - 15GHZ
HP-15-xxxx-xx
HP2-15-xxxx-xx
AD15G-xx-S2
AD15G-xx-S2
HP ODUs - 18 GHZ
HP-18-xxxx-xx
HP2-18-xxxx-xx
AD18G-xx-S2, R2
AD18G-xx-S2, R2
HP ODUs - 23 GHZ
HP-23-xxxx-xx
HP2-23-xxxx-xx
AD23G-xx-S2, -R2
AD23G-xx-S2, -R2
HP ODUs - 26 GHZ
HP-26-xxxx-xx
HP2-26-xxxx-xx
AD26G-xx-S2
AD26G-xx-S2
HP ODUs - 26 GHZ
HP-28-xxxx-xx
AD28G-xx-R2
HP ODUs - 32 GHZ
HP-32-xxxx-xx
AD32G-xx-R2
HP ODUs - 38 GHZ
HP-38-xxxx-xx
HP-38-xxxx-xx
HP2-38-xxxx-xx
AD38G-xx-R2
AD38G-xx-R2
AD38G-xx-R2
TrangoSystems,Inc.
OMC-38-HP
OMC-38-HP
OMC-38-HP
GigaPlusUserManualRev1.3
215
AppendixFLinkInstallandCommissioningLogs
Standardizedformsareprovidedhereforuseduringtheinstallationandconfiguration
phaseandtoserveasarecordofthelinkperformanceatthetimeofinstallation.
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
216
SiteInformation
Customer:
SiteName:
SiteAddress:
SiteCoordinates:
IDUModel:
IDUSerial#
ODUModel:
ODUSerial#
SiteAccessnotes:
AntennaInformation
Antennamodel
Antennasize
HeightaboveGroundLevel
DoesitmeetFresnelzonerequirement?
YesNo
AntennaMountisproperlysecure?
YesNo
IstheAntennaproperlysecure?
YesNo
IstheMountProperlygrounded?
YesNo
IstheAntennaProperlygrounded?
YesNo
IstheAntennasidestrutinstalled?
YesNo
IstheAntennaweatherproof?
YesNo
WastheORinginstalledproperly?
YesNo
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
217
OutdoorUnitInformation
ModelofODU:
DirectorRemoteODUMount
DirectRemote
Areallfourlatchesproperlyclosed?
YesNo
WhatistheODUpolarization?
HV
DoestheODUlookdamaged?
YesNo
IstheGoreVentdamaged?
YesNo
PowerSupplyInformation
TypeofpowerSupply:
RedundantpowertotheIDU?
YesNo
MeasureinputvoltageatIDU
(VDC)
ProperlygroundedtotheEarth?
YesNo
Aretheleadsproperlyterminatedtothepower
supplysterminalblock
YesNo
IFCableInformation
Cabletype:
CableLength:
SecureconnectiontotheODU?
SecureconnectiontotheIDU?
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
218
Properweatherproofingatallnecessary
Points?
YesNo
Pointofentryproperlyweatherproof?
YesNo
Pointofentryproperlygrounded?
YesNo
IsthereadriploopattheODU?
YesNo
Lightningsuppressoratbaseoftower
YesNo
Remarks:
Model:
LightningsuppressoratODU
YesNo
Model:
Isthereanydamagetothecable,bends,
kinks,etc.?
YesNo
Remarks:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
219
Notes:
InstallationPerformedby:
Name:
Date:
Title:
ContactNumber:
Company:
Signature:
InstallationApprovedby:
Name:
Date:
Title:
ContactNumber:
Company:
Signature:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
220
LinkConfigurationLog
SiteAInformation
Customer:
SiteName:
SiteAddress:
SiteCoordinate:
SiteConfiguration:
1+0/1+1/2+0(CircleOne)
SiteAccessnotes:
CompleteafterLinkConfigurationcompleted
SiteAConfigurationPerformedby:
Name:
Date:
Title:
ContactNumber:
Company:
Signature:
SiteAConfigurationApprovedby:
Name:
Date:
Title:
ContactNumber:
Company:
Signature:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
221
SiteAUnit#1Information
ModelofODU
ODUSerialNumber
IDUSerialNumber
IDUMACAddress
IDUIPAddress
OBM:
IBM:
Polarizationofthisunit
VorH
AntennaModel
AntennaSerialNumber
TransmitFrequencySetting
MHz
TransmitPowerSetting
dBm
Speed/ModulationSetting
AdaptiveCoding&Modulation
ON/OFF
AutomaticTransmitPowerControl
ON/OFF
TargetRSSISetting
dBm
RecordedRSSI
dBm
ExpectedRSSIfromPCN
dBm
RecordedMSE
dB
Linktest99:stableRSSI,MSE,Lock?
Yes/No
24HourTrafficTest
NoErrorsPass/Errors:Fail
Utype
Active/Standby
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
222
SiteAUnit#2Information
ModelofODU
ODUSerialNumber
IDUSerialNumber
IDUMACAddress
IDUIPAddress
OBM:
IBM:
Polarizationofthisunit
VorH
CombinerModel
CombinerSerialNumber
TransmitFrequencySetting
MHz
TransmitPowerSetting
dBm
Speed/ModulationSetting
AdaptiveCoding&Modulation
ON/OFF
AutomaticTransmitPowerControl
ON/OFF
TargetRSSISetting
dBm
RecordedRSSI
dBm
ExpectedRSSIfromPCN
dBm
RecordedMSE
dB
Linktest99:stableRSSI,MSE,Lock?
Yes/No
24HourTrafficTest
NoErrorsPass/Errors:Fail
Utype
Active/Standby
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
223
SiteBInformation
Customer:
SiteName:
SiteAddress:
SiteCoordinate:
SiteConfiguration:
1+0/1+1/2+0(CircleOne)
SiteAccessnotes:
CompleteafterLinkConfigurationcompleted
SiteBConfigurationPerformedby:
Name:
Date:
Title:
ContactNumber:
Company:
Signature:
SiteBConfigurationApprovedby:
Name:
Date:
Title:
ContactNumber:
Company:
Signature:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
224
SiteBUnit#1Information
ModelofODU
ODUSerialNumber
IDUSerialNumber
IDUMACAddress
IDUIPAddress
OBM:
IBM:
Polarizationofthisunit
VorH
AntennaModel
AntennaSerialNumber
TransmitFrequencySetting
MHz
TransmitPowerSetting
dBm
Speed/ModulationSetting
AdaptiveCoding&Modulation
ON/OFF
AutomaticTransmitPowerControl
ON/OFF
TargetRSSISetting
dBm
RecordedRSSI
dBm
ExpectedRSSIfromPCN
dBm
RecordedMSE
dB
Linktest99:stableRSSI,MSE,Lock?
Yes/No
24HourTrafficTest
NoErrorsPass/Errors:Fail
Utype
Active/Standby
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
225
SiteBUnit#2Information
ModelofODU
ODUSerialNumber
IDUSerialNumber
IDUMACAddress
IDUIPAddress
OBM:
IBM:
Polarizationofthisunit
VorH
CombinerModel
CombinerSerialNumber
TransmitFrequencySetting
MHz
TransmitPowerSetting
dBm
Speed/ModulationSetting
AdaptiveCoding&Modulation
ON/OFF
AutomaticTransmitPowerControl
ON/OFF
TargetRSSISetting
dBm
RecordedRSSI
dBm
ExpectedRSSIfromPCN
dBm
RecordedMSE
dB
Linktest99:stableRSSI,MSE,Lock?
Yes/No
24HourTrafficTest
NoErrorsPass/Errors:Fail
Utype
Active/Standby
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
226
AppendixGDeclarationofConformity
We,TrangoSystems,Inc.,
14118StoweDrive
SteB
Poway,California,92127USA
Tel+18583910010
Fax+18583910020
Herebydeclarethattheproduct(s)listedbelow,
Product Name:
Model No:
Product Name:
Model No:
Where:
XX = the Frequency Band in GHz
YYYY= the T/R Spacing
ZZ= the Sub-band
Towhichthisdeclarationrelates,areinconformitywiththefollowingstandardsand/orothernormative
documents:
EN30221722(200704)
EN30221721(200508)
EN30148917v1.2.1(200208)
EN609501/IEC609501:2001FirstEdition
EN50385:2002
Weherebydeclarethatallessentialradiotestsuiteshavebeencarriedoutandthattheabovenamed
productsareinconformitywithalltheessentialrequirementsofDirective1999/5/EC.
TheconformityassessmentprocedurereferredtoinArticle10(5)anddetailedinAnnexIVofDirective
1999/5/EChasbeenfollowedwiththeinvolvementofthefollowingNotifiedBodyusingtheCBScheme:
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
227
Glossary
AGC
ATPC
BER
BPF
Cat5e
COS
dB
dBm
E1
FCC
FEC
FPGA
FTP
GigE
HTTP
HTTPD
HTTPS
IF
IDU
LB
LDPC
LED
LIU
MSE
ODU
Opmode
OS
PIC
PoE
QAM
QoS
QPSK
RF
RJ45
RS232
RSSI
Rx
SFP
SNMP
SSH
Sysinfo
AutomaticGainControl
AutomaticTransmitPowerControl
BitErrorRate
BandPassFilter
Category5enhancedCable
ClassOfService
Decibel
Decibelrelativetoonemilliwatt
EuropeanCarrier1
FederalCommunicationCommission
ForwardErrorCorrection
FieldProgrammableGateArray
FileTransferProtocol
GigabitEthernet
HyperTextTransferProtocol
HyperTextTransferProtocolDaemon
HyperTextTransferProtocolSecure
IntermediateFrequency
IndoorUnit
Loopback
LowDensityParityCheck
LightemittingDiode
LineInterfaceUnit
MeanSquareError
OutdoorUnit
OperationMode
OperatingSystem
ASeriesofmicrocontrollersaproductoftheMicrochipTechnology
PowerOverEthernet
QuadratureAmplitudeModulation
QualityofService
QuadraturePhaseShiftKeying
RadioFrequency
RegisteredJack45
RecommendedStandard232
ReceiveSignalStrengthIndicator
Receive
SmallFormfactorPluggable
SimpleNetworkManagementProtocol
SecureShell
SystemInformation
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
228
T1
TDM
T/I
TFTP
TFTPD
Tx
VLAN
WISP
1.544Mbpstelephonycarrier1
TimeDivisionMultiplexing
ThresholdtoInterference
TrivialFileTransferProtocol
TrivialFileTransferProtocolDaemon
Transmit
VirtualLocalAreaNetwork
WirelessInternetServiceProvider
TrangoSystems,Inc.
GigaPlusUserManualRev1.3
229