Вы находитесь на странице: 1из 229

TrangoLINK GigaPlus

6-40 GHz
Split Architecture High Capacity Point to Point Microwave Backhaul System

User Manual
Revision1.3

Notice
ThisdocumentcontainsinformationthatisconfidentialandproprietarytoTrango
Systems,Inc.Nopartofthecontentofthispublicationmaybereproduced,modified,
used,copied,disclosed,conveyed,ordistributedtoanypartyinanymannerwhatsoever
withoutpriorwrittenauthorizationfromTrangoSystems,Inc.Thisdocumentisprovided
asis,withoutwarrantyofanykind.

Trademarks
TrangoSystems,TrangoLINK,andTrangoLINKGigaareregisteredtrademarksof
TrangoSystems,Inc.Othernamesmentionedinthispublicationareownedbytheir
respectiveholders.

StatementofConditions
Theinformationcontainedinthisdocumentissubjecttochangewithoutnotice.Trango
Systems,Inc.shallnotbeliableforerrorscontainedhereinorforincidentalor
consequentialdamageinconnectionwiththefurnishing,performance,oruseofthis
documentorequipmentsuppliedwithit.

InformationtoUser
Anychangesormodificationsofequipmentnotexpresslyapprovedbythe
manufacturercouldvoidtheusersauthoritytooperatetheequipmentandthe
warrantyforsuchequipment.

TrangoSystems,Inc.
14118StoweDrive,SuiteB
Poway,CA92064
Tel.:+1(858)3910010
Fax:+1(858)3910020

Copyright2011byTrangoSystems,Inc.Allrightsreserved.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

Contents
Tables ..................................................................................................... 9
Figures ................................................................................................. 10
Revision History .................................................................................. 13
Preface ................................................................................................. 14
Reference conventions ....................................................................... 15
Warranty Information .......................................................................... 15
Contacting Trango Technical Support .............................................. 15
Standards Compliance........................................................................ 16
1.0

Product Description ................................................................... 17

Overview ............................................................................................................ 17
Ports and Indicators Indoor Unit ...................................................................... 19
Location of Serial No. and Out of Band MAC address........................................ 22
Ports and Indicators Outdoor Unit ................................................................... 22
Antenna Connection ........................................................................................... 24
Remote Mounting ............................................................................................... 24
Combiners for Antenna Sharing ......................................................................... 24
Power Supply ..................................................................................................... 25
Key Features ...................................................................................................... 26
Flexible Interfaces and Form Factor ................................................................... 26
Traffic Capacity................................................................................................... 26
Industry Leading System Gain............................................................................ 27
Full Licensed band frequency and T/R spacing support ..................................... 28
Channel Sizes from 3.5 MHz to 80 MHz ............................................................. 29
Adaptive Coding and Modulation ........................................................................ 29
Link Protection through 1+1 Hot Standby ........................................................... 30

2.0

Wireless Operation Detail .......................................................... 31

Channel Bandwidth ............................................................................................ 31


Modulation .......................................................................................................... 31
Mean Squared Error (MSE) ................................................................................ 31
Adaptive Coding and Modulation (ACM) ............................................................ 33
Wireless Link Capacity ....................................................................................... 36
Automatic Transmit Power Control (ATPC) ........................................................ 37
ATPC Max Power & Step Size ........................................................................... 37
Transmitter Maximum Power Output .................................................................. 37
Transmitter Minimum Power output .................................................................... 38

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

Receiver Maximum Input .................................................................................... 39

3.0

Network Operation Detail .......................................................... 40

1+0 Non-Protected Link Configuration ............................................................... 40


1+1 Hot Standby Protected Link Configuration ................................................... 41
Hardware triggered failover ........................................................................... 42
Software triggered failover ............................................................................ 43
User triggered (manual) failover .................................................................... 43
Rapid Port Shutdown (RPS) ............................................................................... 44
VLAN Tagging .................................................................................................... 44
Port Mapping (802.1q) ........................................................................................ 45
Q in Q/Double Tagging and smart_mode ........................................................... 45
Class of Service (802.1p) ................................................................................... 46
Port Priority ......................................................................................................... 46
Port Rate Limiting (Ingress) ................................................................................ 47

4.0

Link Management ....................................................................... 48

Overview ............................................................................................................ 48
Graphical User Interface (Web Browser) ............................................................ 49
Command Line Interface (CLI) using SSH, Telnet or Console ........................... 52
Changing Password ...................................................................................... 54
Console Port ................................................................................................. 54
Simple Network Management Protocol (SNMP) ................................................. 55
Common Objects for Monitoring and Control ................................................ 56
Firmware Upgrade .............................................................................................. 57
Upgrade Procedure -TFTP ............................................................................ 58
Upgrade Procedure -FTP .............................................................................. 60
Capacity Upgrades ............................................................................................. 62

5.0

Link Planning .............................................................................. 63

Frequency/Path Planning ................................................................................... 63


Site Selection...................................................................................................... 63
Licensing ............................................................................................................ 63

6.0

Installation .................................................................................. 64

Safety ................................................................................................................. 64
Installation Process ............................................................................................ 67
Preparing for Installation ..................................................................................... 67
Tools ................................................................................................................... 67
Grounding Overview ........................................................................................... 68
Power Supply Installation ................................................................................... 69
Antenna Installation ............................................................................................ 70
Install the IDU ..................................................................................................... 70
Connecting power............................................................................................... 71
Ferrite Installation .......................................................................................... 72
1+1 Hot Standby IDU Installation ....................................................................... 73
HP ODU Installation on Antenna ........................................................................ 74

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

IF Cable Installation ............................................................................................ 76


Weather Proofing Cabling .................................................................................. 78
1+1 Hot Standby ODU Installation ...................................................................... 79

7.0

Link Configuration ..................................................................... 80

Web Based Configuration ................................................................................... 81


Web Based 1+0 Setup .................................................................................. 81
Web Based 1+1 Setup .................................................................................. 85
Adaptive Coding and Modulation (ACM) (Optional) ...................................... 86
Automatic Transmit Power Control (ATPC) (Optional) .................................. 87
Alarms, RPS and Telnet/TFTP Daemons...................................................... 87
Ethernet Configuration .................................................................................. 88
Status Monitoring Overview .......................................................................... 89
System Status ............................................................................................... 89
Link Status .................................................................................................... 90
Ethernet Statistics ......................................................................................... 91
RF Statistics .................................................................................................. 92
T1/E1 Statistics ............................................................................................. 93
Contains industry standard statistical information on each T1/E1 interface,
updated every 20 seconds. ................................................................................ 93
Diagnostic Options ........................................................................................ 94
Reset Config will restore all the setting on the IDU to factory except the IP
stack and the license keys. ................................................................................. 94
System Log ................................................................................................... 95
Config View ................................................................................................... 96
Config View allows complete display of the system configuration and also
exporting the configuration file as a record of the system setup. By clicking
on the Config Export button, the system will generate a config.txt file.
Follow the same procedures mentioned under the Diagnostic Export section
above to download the config.txt file................................................................... 96
User Settings................................................................................................. 97
Allows setting the system remark for the IDU which is displayed at the top of
every web page, as well as changing the Login Password for the web (HTTP)
interface. ............................................................................................................. 97
Command Line Interface (CLI) Based Configuration .......................................... 98
CLI Based 1+0 Configuration ........................................................................ 98
CLI Based 1+1 Hot Standby Configuration ................................................. 104
Antenna Alignment ........................................................................................... 105
CLI Common Task Reference .......................................................................... 107
Setting up the In-Band-Management (IBM) ................................................. 107
Capacity License Activation ........................................................................ 109
Automatic Transmit Power Control (ATPC) Configuration (optional) ........... 109
Check Ethernet and RF port Statistics ........................................................ 110
Enable Traps (Optional) .............................................................................. 113

8.0

Troubleshooting ....................................................................... 114

Symptom: No Link (Lock = 0 during linktest) .................................................... 114


TrangoSystems,Inc.

GigaPlusUserManualRev1.3

MSE is too high and/or bit errors are showing when running linktest ............... 114
Receive Signal Level is too low ........................................................................ 115
RF Link is good but packet loss is occurring: ................................................... 116
No direct management using Out of band port ................................................. 116
No Radio Management connection over the link .............................................. 117
T1/E1 Ports not passing traffic.......................................................................... 117

Appendix A Command Line Interface Reference ........................ 118


Command Keying Overview ............................................................................. 118
Key Functions ............................................................................................. 118
Different Node Levels ....................................................................................... 119
View Node ................................................................................................... 119
Config Node ................................................................................................ 121
Debug Node ................................................................................................ 126
Individual Command Details ............................................................................. 127
acm ............................................................................................................. 127
alarm ........................................................................................................... 128
atpc ............................................................................................................. 129
ber ............................................................................................................... 130
bootimage ................................................................................................... 130
cableloss ..................................................................................................... 131
config .......................................................................................................... 132
cos .............................................................................................................. 133
datapath ...................................................................................................... 135
datapattern .................................................................................................. 136
date ............................................................................................................. 136
debug .......................................................................................................... 137
defaultopmode ............................................................................................ 138
diagnostics .................................................................................................. 138
eth_info ....................................................................................................... 139
exit .............................................................................................................. 140
failover ........................................................................................................ 140
fanctrl .......................................................................................................... 142
freq .............................................................................................................. 142
freq_duplex ................................................................................................. 143
ftp ................................................................................................................ 144
help / ? ........................................................................................................ 145
guard_time .................................................................................................. 146
httpd ............................................................................................................ 146
ibm .............................................................................................................. 147
ipconfig ........................................................................................................ 148
license ......................................................................................................... 149
link_history .................................................................................................. 150
linktest ......................................................................................................... 150
loglevel ........................................................................................................ 151
loopback ...................................................................................................... 152
model .......................................................................................................... 152
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

mse ............................................................................................................. 153


oduled ......................................................................................................... 153
odupower .................................................................................................... 154
odurxagc ..................................................................................................... 155
opmode ....................................................................................................... 156
passwd ........................................................................................................ 156
port .............................................................................................................. 157
power .......................................................................................................... 158
prompt ......................................................................................................... 159
reboot .......................................................................................................... 160
remark ......................................................................................................... 160
reset ............................................................................................................ 161
rps ............................................................................................................... 162
rssi .............................................................................................................. 162
siglevel ........................................................................................................ 163
snmpd ......................................................................................................... 164
speed .......................................................................................................... 165
status .......................................................................................................... 169
sync ............................................................................................................. 170
sync_state ................................................................................................... 170
sysinfo ......................................................................................................... 171
syslog .......................................................................................................... 172
targetrssi ..................................................................................................... 173
tdm .............................................................................................................. 173
telnetd ......................................................................................................... 174
temp ............................................................................................................ 174
tftpd ............................................................................................................. 175
threshold ..................................................................................................... 176
trap .............................................................................................................. 177
uptime ......................................................................................................... 178
utype ........................................................................................................... 178
utype_switch ............................................................................................... 179
version ........................................................................................................ 180
voltage ........................................................................................................ 181

Appendix B Product Specifications .............................................. 182


Dimensions and Weight .............................................................................. 182
Environmental ............................................................................................. 182
Emissions .................................................................................................... 182
Reliability ..................................................................................................... 183
Electromagnetic Compliance....................................................................... 183
Wireless Compliance .................................................................................. 183
Wireless Parameters ................................................................................... 184
Transmitter Power ....................................................................................... 184
Radio Sensitivity 6 to 26 GHz...................................................................... 185
Radio Sensitivity 28 to 38 GHz.................................................................... 185
1+1 Hot Standby Link Protection ................................................................. 186
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

Specification ................................................................................................ 186


Power .......................................................................................................... 186
User Interfaces ............................................................................................ 186
Ethernet Parameters ................................................................................... 187
T1/E1 Parameters ....................................................................................... 187

Appendix C Cable Wiring............................................................... 188


Ethernet Cabling ............................................................................................... 188
T1/E1 Cabling ................................................................................................... 189
DB9 Port Interfaces .......................................................................................... 190
DB9 Console cable Pin-outs ............................................................................. 190
DB9 Alarm Port Pin-outs .................................................................................. 191

Appendix D MIB OID Listing .......................................................... 192


Appendix E Part Numbers ............................................................. 203
GigaPlus HP ODU Sub-bands/Tuning Ranges................................................. 203
Accessories ...................................................................................................... 215

Appendix F Link Install and Commissioning Logs ..................... 216


Appendix G Declaration of Conformity ........................................ 227
Glossary ............................................................................................. 228

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

Tables
Table 1: TrangoLINK GigaPlus part numbers ........................................................ 14
Table 2 Combiner Cross Reference......................................................................... 25
Table 3 GigaPlus Band and T/R Spacing Options .................................................. 28
Table 4 MSE Expected and Maximum Values ......................................................... 32
Table 5 ACM Threshold Table ................................................................................. 34
Table 6 Max Link Capacity (Mbps) for non-ACM Speed Settings ............................ 36
Table 7 Maximum Set Power Levels by Band and Modulation ................................ 38
Table 8 Minimum TX set power by band.................................................................. 38
Table 9 Max Receive Level Input ............................................................................. 39
Table 10 Failover Events ......................................................................................... 42
Table 11 Default Login Passwords .......................................................................... 49
Table 12 Recommended Torque ............................................................................. 70
Table 13 RSSI to Voltage Conversion ................................................................... 106
Table 14 T1/E1 Cable Wiring ................................................................................. 189
Table 15 Console Cable Pin-outs .......................................................................... 190
Table 16 Alarm Port Pin Functions ........................................................................ 191

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

Figures
Figure 1 IDU Functional Block Diagram ................................................................... 17
Figure 2 ODU Functional Block Diagram ................................................................. 18
Figure 3 Front Panel of GigaPLUS IDU ................................................................... 19
Figure 4 Side of IDU (Shows where MAC address can be found) ........................... 22
Figure 5 Outdoor Unit Connectors/Indicators (HP Model)........................................ 22
Figure 6 Polarization Indicator ................................................................................. 23
Figure 7 ODU Label ................................................................................................. 24
Figure 8 LDPC vs. Reed-Solomon ........................................................................... 27
Figure 9 Adaptive Coding and Modulation (ACM) .................................................... 29
Figure 10 1+0 Setup ................................................................................................ 40
Figure 11 1+1 Setup ................................................................................................ 41
Figure 12 Web Browser Login ................................................................................. 49
Figure 13 System Info Page .................................................................................... 50
Figure 14 Console Port Setting ................................................................................ 55
Figure 15 Windows Start & Telnet ........................................................................... 58
Figure 16 Capacity Upgrade in Link Setup Page ..................................................... 62
Figure 17 Site Based Grounding Diagram ............................................................... 68
Figure 18 IDU with Rack Ears installed .................................................................... 70
Figure 19 Power Connection on Front Panel ........................................................... 71
Figure 20 -48 VDC Power Connector Wiring ........................................................... 71
Figure 21 Ferrite ...................................................................................................... 72
Figure 22 Ferrite Installed ........................................................................................ 72
Figure 23 1+1 Hot Standby (IDUs) with CBLDAT-RIU3 ........................................... 73
Figure 24 Antenna to HP ODU Slip Fit Waveguide connection ............................... 74
Figure 25 Polarization Indication .............................................................................. 75

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

10

Figure 26 Latch ........................................................................................................ 75


Figure 27 Right Angle N-Connector Mount .............................................................. 77
Figure 28 Weather Proofing of cable ....................................................................... 78
Figure 29 Complete weather proofing of cable ........................................................ 78
Figure 30 ODUs on SMC combiner (1+1) ................................................................ 79
Figure 31 Web Interface Login ................................................................................. 81
Figure 32 Web Login with Password........................................................................ 81
Figure 33 System Information Page......................................................................... 82
Figure 34 IP Configuration Page .............................................................................. 83
Figure 35 Link Setup Page ...................................................................................... 84
Figure 36 Failover Mode Set .................................................................................... 85
Figure 37 ACM Setup .............................................................................................. 86
Figure 38 ATPC Setup/ RPS /Telnetd/ tftpd/alarms ................................................. 87
Figure 39 Ethernet Setup Page ............................................................................... 88
Figure 40 System Status Page ................................................................................ 89
Figure 41 Link Status Page ...................................................................................... 90
Figure 42 Ethernet Statistics Page........................................................................... 91
Figure 43 RF Statistics Page ................................................................................... 92
Figure 44 T1/E1 Statistics Page .............................................................................. 93
Figure 45 Diagnostic Options ................................................................................... 94
Figure 46 System Log .............................................................................................. 95
Figure 47 Config View.............................................................................................. 96
Figure 48 User Settings & Password ....................................................................... 97
Figure 49 BNC Connector for RSSI Voltage .......................................................... 105
Figure 50 EIA/TIA 568A Straight through ............................................................... 188
Figure 51 EIA/TIA 568B Cross-Over ...................................................................... 188
Figure 52 Console Cable Connector ...................................................................... 190

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

11

Figure 53 Alarm Port Pin Identification................................................................... 191

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

12

RevisionHistory
Revision
1.0
1.3

Revision Date
22 Apr 2010
6 June 2011

Description
Initial Release
Update to new format and add detail on new features in SW V 1.3

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

13

Preface
ThismanualcoversthebasicconfigurationandinstallationoftheTrangoLINKGigaPlus
licensedmicrowavebackhaulsystem,

Thisdocumentisintendedtoinstructandassistpersonnelintheoperation,installation
andmaintenanceoftheTrangolinkGigaPlusmicrowavebackhaulsystemandrelated
accessoriesshowninTable1.

Itisrecommendedthatallpersonnelengagedinsuchactivitiesbeproperlytrained.
TrangoSystemsdisclaimsallliabilitywhatsoever,impliedorexpress,foranyriskof
damage,lossorreductioninsystemperformancearisingdirectlyorindirectlyoutofthe
failureofthecustomer,oranyoneactingonthecustomer'sbehalf,toabidebythe
instructions,systemparameters,orrecommendationsmadeinthisdocument.
Part Number

Description

GigaPLUSIDU1

TrangoLINKGigaPLUSIndoorUnit,100MbpsFullDuplex,rack
mount(AllFrequencyVersions)ANSI/ETSI

HPXXYYYYZZ

TrangoLINKHighPower(HP)OutdoorUnit,640GHz

HP2XXYYYYZZ

TrangoLINKHighPower(HP2)OutdoorUnit,640GHz

PSUPPLYDT48
CBLDAT3
CBLDATRIU3
CBLDATRSSI
GigaPlusKEY1
GigaPlusKEY2
SFPGigEC
SFPGigES
SFPGigEM

48VoltUniversalDesktopPowerSupply
SerialConsoleCableforGigPlus
1+1HotStandbyCableforGigaPlus
BNCMtoBananaplugcableforRSSIvoltagemeasurement
SoftwareKeytoAllowThroughputsupto200Mbps
SoftwareKeytoAllowThroughputsupto375Mbps
SFP1000BaseTCopperRJ45
SFPFiberSingleModeModule
SFPFiberMultiMode

Table1:TrangoLINKGigaPluspartnumbers
Specificpartnumbersforradiounitsubbandsandbandspecificaccessoriessuchas
antennas,combinersandremotemountscanbefoundinAppendixE.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

14

Referenceconventions

Thisdocumentutilizesseveralconventions.

Allsystemcommandreferencesareshowninbolditalics.
Allreferencestoexternalpublicationsareshowninbold.

WarrantyInformation
TrangoLINKGigaPlusunitspurchasedfromTrangoSystems,Inc.arewarrantedfortwo
yearsfromdateofpurchase.Pleaseseewww.trangosys.comforacompletedescription
ofwarrantycoverageandlimitations.
ExtendedwarrantyprotectioncanbepurchasedthroughTrangoSalesorCustomer
Service(+18583910010).

ContactingTrangoTechnicalSupport
ShouldassistanceberequiredoranRMAberequired,youmaycontactthetechnical
supportdepartmentusingthefollowingmethods:
Address:
TrangoSystems,Inc.
14118StoweDr
SuiteB
Poway,CA,92064
USA
Phone:(858)3910010from8amto5pmPacificStandardTime.
Email:techsupport@trangosys.com
Web:www.trangosys.com

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

15

StandardsCompliance
FederalCommunicationsCommission(FCC)
ANSImodelsoftheTrangoLINKGigaPlusproductlinehavebeentestedandfoundto
complywiththefollowingFCCstandards:
CFR47Part15
CFR47Part101
AppendixEshowsthespecificpartnumbersthathavebeentested.

FederalCommunicationsCommission(FCC)EmissionDesignators

10M0D7Wfor10MHzBWratesandallmodulations

20M0D7Wfor20MHzBWratesandallmodulations

30M0D7Wfor27.5/28/30MHzBWratesandallmodulations

40M0D7Wfor40MHzBWratesandallmodulations

50M0D7Wfor50MHzBWratesandallmodulations

56M0D7Wfor55/56/80MHzBWratesandallmodulations

EuropeanTelecommunicationsStandardsInstitute(ETSI)
ETSImodelsoftheTrangoLINKGigaPlusproductlinehavebeentestedandfoundto
complywiththeEuropeanTelecommunicationsStandards:

EN30221721V1.2.1(200702)

EN30221722V1.2.2(200704)

EN3014891V1.8.1(200804)

EN3014894V1.4.1(200809)

EN609501,EN6095022

ThesestandardscoveralltheessentialrequirementsofDirective1999/5/EC.AppendixE
showsthespecificpartnumbersthathavebeentested.

RoHSCompliance
TheTrangoLINKGigaPlusproductlinecomplieswiththeEuropeanUnion(EU)
Directive2002/95/EContheRestrictionofHazardousSubstances(RoHS).

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

16

1.0 ProductDescription
Overview
TheTrangoLINKGigaPlusisahighperformancesplitarchitecturepointtopoint
wirelessmicrowavesystemdesignedforCarrier,Enterprise,andServiceProvider
networksusingthe640GHzlicensedspectrum.Thesystemprovidesafullduplex
wirelessLayer2Ethernetconnectionwithultralowpacketlatencyandjitter,and
supportsuptofour10/100/1000BaseT,twoEthernetFiberinterfaces,andeightT1/E1
interfacesfortimingorlegacyTDMsupport.
GigaPluswascreatedtoallowthehighestperformancepossibleacrossallstandard
frequencybandsandTRspacings.Eachendofthelinkconsistsofonecompactrack
width,1RUhighIndoorUnit(IDU)andoneOutdoorRFunit(ODU),connectedviaa
singlecoaxialcableupto1000feetlong.Figures1and2showthefunctionalblock
diagramofthesystemastheyaredividedbetweentheIDUandODU.

Figure1IDUFunctionalBlockDiagram

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

17

Figure2ODUFunctionalBlockDiagram
TheTrangoLINKGigaPlusisaFrequencyDivisionDuplex(FDD)radiowhichprovideslow
latencyoflessthan150microseconds(s),over1millionpacketspersecond,andupto
375Mbpsoffullduplexcapacity.StandardfeaturesincludeQualityofService(QoS)
trafficprioritizationtoensurethatcriticaltrafficgetsthrough,aswellasAdaptive
CodingandModulation(ACM)toimproveperformanceduringweatherrelatedsignal
degradation.
GigaPlussupportsdirect48VoltDCdualpowertoallowforredundantpowersupplies.
TheIDUpowerinputhasreversevoltageprotectiontopreventdamageandsurge
suppressioncircuitrytoreducesusceptibilitytonoise.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

18

PortsandIndicatorsIndoorUnit
TheFigurebelowshowsthevariousportsontheGigaPlusIDU.

Figure3FrontPanelofGigaPLUSIDU

TheTrangoLINKGigaPLUSfrontpanelinterfaceisdescribedbelow:
NTypeConnector(ODU):TheNTypeConnectorconnectstheIDUtotheODUthrough
coaxialcable.ThisportcarriesthetransmitandreceiveIFfrequencies,theODUcontrol
signal,andthe48VDCpowertotheODUonthecenterconductor.NMaletoNMale
cableterminationsarerequiredandLMR400isrecommendedformostinstallations.
GroundLug:Allowsforpropergroundingofthechassistotherack,whichisearth
grounded.
ODUStatusLEDs(2):TopLEDprovidesODUpower/PLLlockstatuswhilethebottom
LEDprovidesRFlinkstatus.IfthetopLEDisamber,theODUisnotpoweredon,not
connected,oroneofthePhaseLockedLoops(PLLs)intheODUisfaulty.Ifthebottom
LEDisamber,RFlinkisnotestablished.IfthelinkisestablishedbothLEDswillbegreen.
DualPowerConnector:Thisisathreepinpluggableterminalblock.TheIDUispowered
bya48Vpowersupply(notincluded).TheGigaPLUSIDUdoessupporttheuseoftwo
powersuppliesforpowerredundancy.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

19

USINGTWOPOWERSUPPLIESFORREDUNDANCY

Thepositive(+)groundwireonbothpowersuppliesshouldbeconnectedtothecenterpinof
thethreepinpluggableterminalblock.Onenegativewirefromthefirstpowersupplyshould
beconnectedtotheleftpinwhiletheothernegativewireofthesecondpowersupplyshould
beconnectedtotherightpin.

FUSING

TheIDUcontainstworesettablefusesthatwillautomaticallyopentheifthecurrentdraw
becomestoohigh,asinashortcircuitcondition.OnefuseisfortheODUNConnector,and
theotherisfortheIDUmainchassiscircuitry.Circuitheatingtriggerstheopening,sothefuse
willresetitselfafteritcoolsdown.Ifthereisarealfaultthefusewillopenagainandthe
problemmustbediagnosed.Thefuseisratedfor1.1ampsmaximumandwillopenwith1.6
orgreaterampscurrentflowing.

T1/E1ports(18):StandardRJ45connectorsbreakoutalltheT1/E1portsinto8RJ45
120Ohmconnectors.
RSSI/PDHLEDs:
RSSIOperation:Bydefault,theIDUdisplaystheactualODUReceiveSignal
StrengthbyilluminatingtheLEDsthat,whenaddedtogether,giveathenegative
dBmindicationoftheReceivedSignalStrength.
Example:LEDs4010and1onlyilluminatedindicatesanRSSIof51dBm
sincethesumoftheLEDvaluesis51.
PDHOperation:Viasoftwarecommand,theLEDscanbemultiplexedtodisplay
theconnectionstatusoftheT1/E1circuit.Thearrowsindicatetheupper(Arrow
pointingup)orlower(arrowpointingdown)portabovetheindicator.
ManagementPorts(RJ4510/100BaseTAutosensing/Autonegotiating):Foroutof
bandWeb,SNMP,Telnet,andSSHmanagement.
RedundancyPort:ConnectthisporttothehotstandbyIDUusingtheredundancy
cable.Note:ThisportisnotastandardEthernetPortandwillnotfunctionusinga
standardEthernetcable.CBLDATRIU3isrequired(optional)
SerialConsolePort(DB9male):1serialRS232portusedtomanageunit.
Alarms(DB9female):Thereare2alarminputswhichareCMOSlevelandareuser
configurable.Thereare2outputswhicharedrycontactratedfor50Volt1Ampseach.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

20

ModeSwitch:TheModeswitchoperatesasfollows:
1) Holdformorethan2seconds,butlessthan6seconds,theunitwill:
a. TheIPaddresswillberesettodefaulttoallowaccessintheeventofa
forgottenpasswordorIPaddress.
b. TheCLImanagementpasswordswillberesettodefault
c. TheWebinterfacepasswordswillberesettodefault.
d. TheSNMPread/write/trapcommunitystringswillbesettodefaults.
e. TheCLIpromptwillbereset.
2) Holdformorethan6seconds:Theunitwillresetthesystemconfigurationto
thefactorydefault,butNOTresettheitemsit(1)above.TheunitWILLREBOOT
automatically.
RESET:RebootsIDUwithoutdisconnectingthepowersupply.
2xGigEports:ETH1andETH2portsarebothRJ4510/100/1000BaseTautosensing
GigEports.
2xSFPPort:ETH3andETH4SFPPortssupporttwoadditionalnative1000BaseTorLC
fiberEthernetconnectionfortraffic.SFPmodulesareavailabletosupporteachas
follows:
a. SFPGigECCopperRJ45moduletosupport1000BaseT
b. SFPGigESSingleModeFiberforlonghaul
c. SFPGigEMMultimodeFiberforshorthaul

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

21

LocationofSerialNo.andOutofBandMACaddress

Figure4SideofIDU(ShowswhereMACaddresscanbefound)

PortsandIndicatorsOutdoorUnit
TheFigurebelowshowsthevariousportsontheGigaPlusHPODU.TheHP2ODUhas
thesameports.

NFemaleIF
Connector

RSSIVoltage
BNCF

AirPressure
Vent

GroundLug

Figure5OutdoorUnitConnectors/Indicators(HPModel)

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

22


GoreTMAirVentTheairventispresenttoprovidepressureequalizationathigh
altitudeswhilepreventingmoisturefromenteringtheunit.Nooperatorinteractionis
necessary.

DONOTTAMPERwiththeAirVent.Itshouldnotbetwistedorremoved.Tampering
withordamagingtheProtectiveVentwillvoidthefactorywarranty.

RSSIVoltageBNCFConnectorThisconnectorisprovidedtoalloweasyantenna
alignmentwhenusedwithamultimeterandtheCBLDATRSSIcable.TheVoltage
presentontheconnectorisdirectlyproportionaltotheReceivedSignalStrengthinthe
receiversectionoftheGigaPlus.
MountingLatchesFourlatchesareprovidedtoalloweasyattachmentoftheGigaPlus
tothestandardantennas,combinersandremotemounts.Twoofthelatcheshave
keyholestoallowlockingtheunittodetertheftand/orsecuretheunit.
PolarizationIndicatorsTheletterVandanarrowarediecastontheODUhousing
perimetertoassistinmountingtheODUtotheantennainthecorrectpolarization.If
thearrowispointedupanddown(asshown)theODUisalignedforvertical
polarization.Ifthearrowispointedleftorrightthenhorizontalpolarizationisbeing
used.

Polarization
indicator

Figure6PolarizationIndicator

GroundingLugODUThegroundlugprovidedontheODUshouldbeconnectedto
thetower/structurelegperthegroundingsectionrecommendations.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

23

LabelsTheSerialnumbers,model,andregulatorycomplianceinformationareshown
ontheODUlabelsattachedtotheODUexterior.

Figure7ODULabel

AntennaConnection
TheODUportionoftheGigaPlusutilizesaslipfitconnectionthatmakesinstallation
simple.TheODUsarealldesignedtomounttoacircularwaveguideantennaor
combinerwiththeexceptionofthe6GHzmodels,whichrequirearectangular
waveguideantenna.For7to40GHzmodels,simplyrotatingtheODUwillchangethe
antennapolarizationbeingused.Acompatibilitylistofantennasisprovidedin
AppendixE.

RemoteMounting
WhenusingtheGigaPlusHPODUswithantennasthatusearectangularwaveguide
interfaceinsteadoftheslipfitcircularwaveguide,aRemoteMountplusflexwaveguide
willberequired.ThecompatibleremotemountsareshowninAppendixE.The
waveguideflangesareavailableformountingallstandardwaveguidesizes.

CombinersforAntennaSharing
TheGigaPlusODUisdesignedwithaneasyslipfitinterfacetotheantenna.Ifdesired,
twounitsmaybeconnectedtothesameantennafor1+1hotstandbyapplicationorto
aggregatetwochannelstogetherformorecapacity.Trangocanprovidemultiple
combineroptionsbasedonthecustomerapplicationsasthetableshowsbelow:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

24

Table2CombinerCrossReference
AppendixEgivesdetailedinformationonwhichspecificfrequencybandsaresupported
foreachtypeofcombiner.

PowerSupply
Trangocanprovidepowersuppliesforrackmountapplications.ThePSUPPLY1U48isa
rackmountpowersupplywith6.5Amperecapacitythatcansupportmultiplecolocated
GigaPlusunits.Thepowersupplymustbekeptinatemperaturecontrolled
environmentwithintheoperatingtempof0to40degC.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

25

KeyFeatures
FlexibleInterfacesandFormFactor
TheGigaPlusisanativeEthernetANDnativeT1/E1radio.Capacitycanbesplitto
supporttheEthernetandT1/E1circuits,ordedicatedtoonlytheEthernet.Thereare2
trafficportsonthefrontpanelthatsupport10/100/1000BaseT,and2thatcansupport
1000BaseTor1000BaseLXSingleorMultimodefiber.
Theformfactorissmallenoughtosupporttwounitsina1Urackspace,andwith
supportforupto1000feetofcabletotheODU,allowsmoreoptionsfortowercable
location.

TrafficCapacity
WithQAM256modulationina56MHzchannel,thelinkcansupportcapacitiesupto
375Mbpsfullduplexor750Mbpsaggregate,with8T1/E1circuitsprovidedforTDM
applications.
Thebasemodelcomeswith100MbpsEthernetfullduplexcapacityandtherearetwo
upgradekeysavailablethatcanopentheentire375Mbpscapacity:
GigaPlusKey1
Description:Unlocksthroughputcapacityfrom100upto200MbpsFullDuplexpayload
(200Mbpseachdirection)Coversonelink(2licensekeysprovided)
GigaPlusKey2:
Description:Unlocksthroughputcapacityfrom100MbpsuptoMaximumcapacityFull
Duplexpayload(375Mbpseachdirection)Coversonelink(2licensekeysprovided)
GigaPlusKeyPDH:
Description:Unlocksthe8T1/E1circuitsonthefrontpanel.100MbpsuptoMaximum
capacityFullDuplexpayload(375Mbpseachdirection)Coversonelink(2license
keysprovided)

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

26

IndustryLeadingSystemGain
ThecombinationoftheHighTransmitpowerandsuperbreceivesensitivityoftheODU
provideforoneofthehighestsystemgainsavailableonthemarkettoday.
ThetechnologybehindthehighsystemgainrelatestotheLowDensityParityCheck
(LDPC)forwarderrorcorrection(FEC)codingthatwasimplementedintheGigaPlus
design.
TheFigurebelowshowshowtheLowDensityParityCheck(LDPC)coding,which
replacestheolderReedSolomonlockcoding,reducesthesignaltonoiseratiorequired
toachievea1E6BitErrorRate(BER).Asaresult,thereceivesensitivityisloweredby
thesameamount,typically3to4dB.

Figure8LDPCvs.ReedSolomon
Systemgainisoneofthemostimportantmetricsforamicrowavesystembecauseithas
adirectrelationshiptothelinkreliability,antennasize,andtransmissiondistanceas
showninthefigurebelow.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

27

FullLicensedbandfrequencyandT/Rspacingsupport
AllstandardfrequencybandsandT/Rspacingsareavailableforthisproductwithno
productrolloutdelays.TheFigurebelowshowsthecurrentlysupportedbandandT/R
spacingsforHPandHP2ODUswhichareusedwiththeGigaPlus.Thenumbers
representthenumberofsubbandsforeachfrequencyband.

Table3GigaPlusBandandT/RSpacingOptions

SpecificinformationonthesubbandsisshowninAppendixE.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

28

ForHPODUmodelstheTRspacingcanbecustomizedviaasoftwarecommandaslong
asthenewTRspacingandchannelbandwidthsarewithinthediplexerrange.
SeeAppendixAformoreinformation

ChannelSizesfrom3.5MHzto80MHz
Acrossallthefrequencybands,thesystemcansupportchannelsizesaslowas3.5MHz.
ThetablebelowshowsthevariouschannelssupportedandtheEthernetcapacitiesfor
eachinnonACMmode.ACMcapacitieswillbeslightlylessduetotheACMoverhead.

AdaptiveCodingandModulation
Adaptivecodingandmodulationprovideserrorfreehitlesschangingofthemodulation
levelforafixedchannelwidthtoallowthelinktobemaintainedduringheavyweather
relatedfadingconditions.Insteadofthelinkdroppingandnotrafficpassing,thelink
willbemaintainedwithalowercapacityuntilthefadingconditionisremoved,atwhich
timethelinkwillreturntothenormalmodulationlevel.
Thetransitionsbetweenmodulationlevelsarecontrolledbythresholdswhichareuser
modifiableandeachtransitionismadewithoutdroppingpacketssincebothendsofthe
linkcoordinatethetransitionautomatically.
TheFigurebelowshowstheAdaptiveCodingandmodulationinaction.

Figure9AdaptiveCodingandModulation(ACM)

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

29

LinkProtectionthrough1+1HotStandby
TwoGigaPlusODUscanbemountedusingacombinerdirectlyonasingleantenna,and
withanoptionalshortjumpercablebetweenthetwoIDUs,provide1+1hotstandby
functionalitytoprotectagainstahardwarefailureofoneGigaPlusIDU,ODUorIFcable.
Thehotstandbyfeatureisavailableonallfrequenciesandcansupportlayer2andlayer
3routednetworkstoallowimmediateroutingofthesignaltothestandbylink.The
failovertimeistypicallylessthan200milliseconds.
1+1isavailableusingequalandunequalpowerdivisioncombinerswiththesame
polarizationforbothODUs.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

30

2.0 WirelessOperationDetail
ChannelBandwidth
Thesystemsupportsthefollowingchannelbandwidths:

3.5MHz
7MHz
10MHz
13.75/14MHz
20MHz
27.5/28MHz
30MHz
40MHz
50MHz
55/56MHz
80MHz

Thespeedischangedviathemanagementinterfaceusingthespeedcommandora
dropdownboxinthewebinterface.Bothsidesofthelinkmustbechanged
independentlytoensuretheRFlinkisestablished.

Modulation
Thefollowingmodulationlevelsaresupportedwithineachofthechannelbandwidths
shownabove:

QAM256
QAM128
QAM64
QAM32
QAM16
QPSK

Themodulationischangedviathemanagementinterfaceusingthespeedcommandor
adropdownboxinthewebinterface.Bothsidesofthelinkmustbechanged
independentlytoensuretheRFlinkisestablished.

MeanSquaredError(MSE)
MeanSquareError(MSE)issimilartoSignaltoNoiseRatio(SNR)exceptthatitaccounts
fordistortionandinterferenceinadditiontonoisepower.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

31

DistortionmaycomefromseveralsourcessuchasbadEthernetcables(poorshield,
damaged,orlowquality),pathdegradationssuchasmultipath,orFresnelzone
encroachment.
Interferencecancomefromothertransmittersonthetower,aswellasfromsources
insideanindoorshelter.Highpowertransmittersinsideasheltercancauseinterference
whennearthePoEdeviceorwhenlocatedveryclosetothecabling.
TherearemaximumacceptableMSEvaluesforeachmodulationwhichareusefulin
determiningthequalityofthelink.TheMSEvaluereportedisonlyrelevanttoonetxrx
path,sotheMSEofeachtxrxpathmustbeevaluatedtoverifythelinkisoperatingas
expected.Thelowerthenumberthebetter,soa35dBisbetterthana30dB.Thetable
belowshowsthemaximumMSEvaluetoexpectinIFLoopback,NormalOperation,and
AbsoluteMaximum.

MSEExpectedandMaximumValues(dB)

MaximumExpectedvalue
IFloopback

QAM256

QAM128

QAM64

QAM32

QAM16

QPSK

36

36

36

36

36

36

MaximumExpectedvalue
Normaloperationatmax
power

34

33

32

30

30

29

AbsoluteMaximumfor1E
6BERSensitivityThreshold

28

25

22

19

16

Table4MSEExpectedandMaximumValues

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

32

AdaptiveCodingandModulation(ACM)
TheACMfeatureworksinconjunctionwiththeMeanSquareError(MSE)values.Using
theacmcommand,theoperatorenablestheACMfunctionandthensetsthespeed
usingthespeedcommand.WhenACMisenabled(on)andthelinkMSEbecomes
degraded,theradiowillautomaticallyshiftdowninmodulationandspeedbasedonthe
MSEdegradethresholdsettingshowninTable5.Sincetheoriginalsetmodulationmay
beQAM256,QAM128,QAM64,QAM32,orQAM16,thetableshowseachsettingand
totalrangeofmodulationlevelsthatwillbeusedforthatsetting.Thethresholdvalues
canbechangedbytheoperatorifdesired,howeverthedefaultvaluesshownarethe
recommendedsettings.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

33

SpeedSettingQAM256
Modulation

Improve

Degrade

QAM256

NA

27.2

QAM64

29.2

24.3

QAM16

25.3

18.5

QPSK

20.3

NA

SpeedSettingusingQAM128
Modulation

Improve

Degrade

QAM128
QAM64
QAM32
QAM16
QPSK

NA

27.2

29.2

24.3

26.3

21.3

25.3

18.5

20.3

NA

SpeedSettingusingQAM64
Modulation

Improve

Degrade

QAM64
QAM32
QAM16
QPSK

NA

24.3

26.3

21.3

25.3

18.5

20.3

NA

SpeedSettingusingQAM32
Modulation

Improve

Degrade

QAM32
QAM16
QPSK

NA

21.3

25.3

18.5

20.3

NA

SpeedSettingusingQAM16
Modulation

Improve

Degrade

QAM16

NA

18.5

QPSK

20.3

NA

Table5ACMThresholdTable
!

TheACMfeaturewillautomaticallyshiftthemodulationlevelupordownbasedonthe
MSEvalueandtheabovespecifiedthresholds.Ifyoudonotwanttheradioto
automaticallychangespeedsettingsthendisableACM.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

34

ACMDetailedDescription
Ifthechannelconditionsdegradeduetomultipathorfading,theMSEmaybeaffected.
Thistypicallyoccursduringheavyrainandismorepronouncedwithhigherfrequencies
andlongertransmissionpaths.
Ifthedegradethresholdshowninthetableisexceeded,theACMenginewillcoordinate
ashiftofthemodulationleveldowntothenextlevelshown.Nopacketswillbe
droppedduringthistransitionsincethetwoendsofthelinkarecoordinatingwitheach
othertoensurethattheswitchoccursatthesametime.Sincelowermodulationlevels
aremorerobustagainstchannelfadingandmultipath,theycantolerateahigherMSEas
isevidentfromthetable.
Ifthelinkconditionscontinuetodegrade,theshiftsdownwardwillcontinueuntilthe
lowestmodulationlevel,QPSK,hasbeenreached.Iffurtherdegradationoccursabove
themaximumMSE(shownpreviouslyinTable5)forQPSK,thelinkwillbedroppedand
packetlosswilloccur.IfthelinkMSEstartstoimprove,however,theACMenginewill
graduallyshiftthemodulationlevelupastheimprovethresholdsarepassed.
WhenACMisactivethemodulationlevelmaybeasymmetrical,meaningthatone
directionmayberunningatQPSKandtheothermayberunningattheoriginallyset
highermodulationsuchas256QAM.ThisisbecausetheACMengineacts
independentlyateachendpointofthelink.AlowlevelBinaryPhaseShiftKeying(BPSK)
channelismaintainedoutofthedatapathbetweenthetwoendsofthelinktoallow
verytightcoordinationoftheswitchesinmodulation.Onlydatatrafficcapacityinthe
directiontowardstheaffectedreceiverwillbereduced,maintainingperformanceon
theunaffecteddirection.
DuringallACMoperationthetransmitterpowerremainsatthesetlevelifATPCisoff.If
enabled,ATPCactsnormallywhenACMisactiveandmayincreaseordecreasethe
transmitpowerbasedonRSSIlevels.
TheacmcommandprovidesconfigurationoftheACMandmustbedoneonbothsides
ofthelink.ThelinktestcommandfromtheCLIcanbeusedtoviewthecurrentTXand
RXmodulationlevels.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

35

WirelessLinkCapacity
ThetablebelowshowsthecapacityofthesystemforeachnonACMspeedsetting.The
capacitiesfortheACMsettingswillbeapproximately12%lowerduetotheadditional
overheadoftheACM.
AllcapacitiesshownareinMbpsfullduplex,meaningthattheaggregatebidirectional
capacityistwicethenumbershown.
Thecapacitiesshownarealsolayer2using1518bytepacketsforIPV4.Layer1numbers
willbehigher,especiallyforsmallpackets:

BW(Mhz)

Symbol
Rate QPSK
(Msps)

4
7
10
14
20
28/30
40
50
55/56/80

3
5.6
8.32
12.2
17.42
26
34.83
43
49.5

4
9
14
21
31
47
63
78
90

QAM16 QAM32 QAM64 QAM128 QAM256

9
19
29
44
63
95
128
157
181

12
24
36
54
78
118
158
195
225

15
30
45
66
96
142
192
238
275

18
35
52
78
111
166
225
277
320

20
39
59
88
126
190
256
318
365*

*375Mbpswhensettospeed80qam256

Table6MaxLinkCapacity(Mbps)fornonACMSpeedSettings

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

36

AutomaticTransmitPowerControl(ATPC)
ATPCandtargetRSSIworktogethertocontroltheremotesidepoweroutputinorderto
achieveoptimalsignalstrength.ATPCcanbeenabledordisabled.Whenenabled,
ATPCwilladjustthepoweroftheremotesidebasedonthelocaltargetRSSIsetting.
IfthecurrentRSSIvalueislowerthanthetargetRSSIsettingofthelocalradio,thelocal
radiowillsendcommandsovertheairinstructingtheremoteradiounittoincreaseits
outputpowertoachievethetargetRSSIsettingwithin+/2dB.
IftheRSSIvalueishigherthatthetargetRSSIsetting,theremoteradiowillbe
commandedtoreducethepoweruntileitherthetargetlevelisreachedwithin+/2dB
ortheTXpowerhashittheminimumlevel(SeeTable8).
ATPChasStepSizeandMaxPowersettingstolimittheoutputpoweroftheunitand
preventaviolationofthelicense.

ThepowersettingcannotbechangedonceATPCisenabled.Tomanuallychangethe
powersetting,ATPCneedstobedisabled.

ATPCMaxPower&StepSize
SettingsforATPCMaxPowerandtheATPCStepSizecontrolhowtheATPCfunctionwill
behavewhenattemptingtoachievetheTargetRSSI.ATPCMaxPoweristhemaximum
powersettingATPCcansetthepoweroutputtowhentryingtoreachtheTargetRSSI.
ATPCStepSizeistheamountofdBperattemptthatATPCcanchangepoweroutput.

TransmitterMaximumPowerOutput
MaximumTransmitterpoweroutputisdependentonthebandofoperationandthe
modulationlevel.BoththeHP1andHP2ODUmodelshavethesamemaximumpower
levelsforeachbandandmodulation.
Thereisnodependencyonthechannelbandwidthusedwithinaparticularband.Asan
example,thepowerlevelforQAM256withinthe6GHzbandisthesamefor3.5MHz
channelsasitisfor56MHzchannels.Thetableillustratesthisandshowsthemaximum
setpowerlevelsforeachmodelfamily,band,andmodulationlevel.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

37


TransmitterMaximum PowerOutputLevel (dBm)

Modulation
Level

6
GHz

7
GHz

8
GHz

10 11 13
15
18
GHz GHz GHz GHz GHz

23
GHz

26
GHz

28
GHz

32
GHz

38
GHz

256QAM

+24

+24

+24

+21

+19

+19

+16

+16

+16

128QAM

+25 +25 +25 +22 +22 +21 +21 +20

+20

+20 +17

+17

+17

64QAM

+25

+25

+25

+22

+22

+21

+21

+20

+20

+20

+17

+17

+17

32QAM

+28

+28

+28

+26

+26

+23

+23

+22

+22

+22

+21

+21

+21

16QAM

+28

+28

+28

+26

+26

+23

+23

+22

+22

+22

+21

+21

+21

QPSK

+30

+30 +30 +28

+28

+26

+26

+25

+25

+25

+23

+23

+23

+21

+20

+20

+19

Table7MaximumSetPowerLevelsbyBandandModulation
WhenATPCisactive,theatpc_maxpowermustbesettothemaximumpowerforthe
highestmodulationused.

TransmitterMinimumPoweroutput
TheminimumtransmitpowerthatcansetislimitedbytheODUmodelandisnot
dependentonthemodulationlevellikethemaximumlevelsare.Thetablebelowshows
theminimumpowerlevelsforeachbandandmodelfamily.Thelevelsarealsothe
minimumlevelsthatATPCcansettheoutputtowhenenabled.

TransmitterMinimumPowerOutputLevel(dBm)

HPODUModel

6
GHz

7
GHz

HPXXYYYYZZ

+9

+9

+9

NA

+6

+3

+3

HP2XXYYYYZZ

+0

+0

+0

+0

+0

+0

+0

8
10
11 13 15
18
GHz GHz GHz GHz GHz GHz

23
GHz

26
GHz

28
GHz

32
GHz

38
GHz

+2

+2

+2

+2

+1

+1

+0

+0

+0

+0

+0

+0

Table8MinimumTXsetpowerbyband

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

38

ReceiverMaximumInput
ThemaximumreceiverRFlevel,measuredbyRSSI,isdepictedinTable9below.Ifthe
RSSIvalueishigherthanlistedforthemodulationbeingused,packetlossmayresult.
Whenoperatingshortrangelinkswithahighreceiverinputlevel,alwaysmakesurethat
thetransmitterpowerisadjusteddownfromthemaximumtoensurethelevelsshown
belowarenotexceeded,oractiveATPCwithatargetrssithatisatleastseveraldB
belowthelevelsshowntoprovideasafetymargin.

ModulationLevel

MaxRSSI

256QAM

24dBm

128QAM

22dBm

64QAM

20dBm

32QAM

18dBm

16QAM

16dBm

QPSK

14dBm

Table9MaxReceiveLevelInput

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

39

3.0 NetworkOperationDetail
Thissectiondescribeskeynetworkrelatedelementsofthesystemindetail.

1+0NonProtectedLinkConfiguration
ThediagrambelowshowsthetypicalsetupoftheGigaPlusinanetworkenvironment.
Althoughthisconfigurationiscallnonprotected,itiscommonlyusedinring
architectureswhichuselayer2or3routingtoreroutethetraffictheotherdirectionif
thelinkfails.
TheFigurebelowshowsthenonprotected1+0linksetupwithswitchesorrouters.

Figure101+0Setup

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

40

1+1HotStandbyProtectedLinkConfiguration
Figure11showstheprotected1+1hotstandbyconfiguration.
ThisconfigurationconsistsoftwoGigaPlusunitsateachendofthelink.Theeasiestway
tothinkofa1+1setupisasingle1+0linkoperatingnormallywithanotherstandbylink
readytotakeoverintheeventofafailurecondition.
Thestandbyunitsmonitortheactivelink,includingreceivingthesamesignalfromthe
farend,butthestandbydoesnottransmitasignalunlessitbecomestheactiveunitas
theresultofafailuredetectionandsubsequentfailoverevent.Thestandbyunits
monitorthehealthoftheactiveunitbypollingitthroughtheredundancycablepart
numberCBLDATRIU3.
Ifthereisaneventthattriggersafailoverfromactivetostandby,bothendsofthelink
willswitchtothestandbylink.Thismeansthatanetworkswitchorroutercapableof
RapidSpanningTreeProtocol(RSTP),BGPorOSPFroutingmustmovethetraffictothe
standbylinkonbothends.Toassistinthisprocess,RapidPortShutdown(RPS)canbe
enabledonthefailedunitasanactionafterafailoveroccurs.

Figure111+1Setup

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

41

TheTablebelowshowstheeventswillcauseafailoverfromactivetostandby:
Event

FailoverType
(localSite)

FailoverType
(remotepair)

ModemlinklostonActive

Hardware

Hardware

CLIutype_switch

Software

Hardware

PowersupplyfailureonActive

Software

Hardware

RebootonActive

Software

Hardware

ODUPLLfailureonActive

Software

Hardware

Violationofthresholdsetting

Software

Hardware

Linkrelatedcommand(seelist)

Nofailover

Hardware

PowersupplyfailureonStandby

Nofailover

Nofailover

RebootonStandby

Nofailover

Nofailover

Odupoweron/offonStandby

Nofailover

Nofailover

ODUPLLfailureonStandby

Nofailover

Nofailover

ModemlinklostonStandby

Nofailover

Nofailover

1+1cableremoval/failure

Nofailover

Nofailover

ACMTx/Rxprofilechanges

Nofailover

Nofailover

Table10FailoverEvents

Hardwaretriggeredfailover

IntheeventthatthemodemRXlinkislost(statuschangesfrom1to0),ahardware
triggeredfailoverwilloccurandthefollowingsequenceofactionswilloccur:

Actions:
1) TheIFtransmitsignalwillbeshutoffontheactiveunitandenabledon
thebackupunit
2) ThestandbyGigaPlusutypewillchangefromstandbytoactiveandthe
previouslyactiveunitutypewillchangetostandby.
3) TheEthernetportwillbeshutdownonthenewstandbyunitifRPSwas
enabled.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

42

4) Thefarendofthelinkwillalsofailoversincethetransmitterswitchwill
causethefarendtoloselockaswell.Steps13abovewillrepeatforthe
farend.
Hardwareinitiatedfailovertothebackuppairwilloccuronthefarendunitduetothe
smallgapinthetransmitterbeingswitchedfromactivetostandbyonthelocalside.The
totaltimeforthefailovertooccuristypically150200milliseconds.
Ahardwarefailoverwillonlyoccurthefollowinginitialconditionsaremet,otherwise
noneoftheeventsintheTablewillcauseafailover.

1)
2)
3)
4)

AStandbyunitisdetected
TheactiveRadiohasitsRXlocked.
Theelectiontimeperiodisover.
Theguardtimehaselapsed

Softwaretriggeredfailover
SoftwaretriggeredfailoverisInitiatedbythesoftwarebasedonthefollowing
conditions.Softwarefailoverswilltake35secondsduetothefactthattheeventsare
polledbytheoperatingsoftwareinsidetheunit.

1) ODUPLLunlocked
2) Violationofathresholdsettingwhenfailoverisconfiguredasoneofthe
thresholdactions.
3) PowerSupplyfailure

Usertriggered(manual)failover
InitiatedbyuserissueCLI/SNMP/webcommandsasshownbelow.Typicallytheonly
usertriggeredcommandthatshouldbeexecutedistheutype_switchcommand,which
isusedwhentheoriginalactiveunitisrestoredorreplacedandtheoperatorwantsto
returnittoactivestatus.Theothercommandsarelistedtomaketheoperatoraware
thattheywillcauseanunintentional(andusuallyundesired)failover.
Commandsthatwillforceafailover

1. Usingtheutype_switchcommandtorestoretheactiveafterafailover

a. ThiscommandcanonlybeinitiatedontheActiveunit.
b. AlowlevelcommandissentfromActivetoStandbyunittoturn
ontransmitter.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

43

2. Usercommands:Whentheoperatorchangesthefollowingsettingsonthe
activeunit,anunintentionalfailovermayoccur.Itisnotrecommendedtorun
anyofthesecommandswhileanactive1+1linkisrunning:
a. acmenable
b. bootimageupgradeodu
c. datapath
d. datapattern
e. loopback
f. opmode
g. odupower
h. power
i. reboot
j. speed

RapidPortShutdown(RPS)

GigaPlussupportstheshutdownoftheEthernetportstoassistinreroutingtrafficinthe
eventofalinkfailure.Whenenabledatbothendsofthelink,AllEthernetportsatboth
endsoftheactivelinkwillbeshutdownwithin50mSofthemodemlockstatus
changingfrom1to0ateitherendofthelink.

RPSemulatesacablefailureiftheentirelinkisthoughtofasacable,andwilltriggera
routingchangewhenusedwithaswitchorroutersetupforRapidSpanningTree
Protocol(RSTP)oranotherlayer2routingprotocolatbothends,asisnormalinaring
architecture.Forhigherlayerroutingprotocolstheportsarenormallyleftactiveinthe
eventofalinkloss.

ItishighlyrecommendedthattheoperatorenableACMwhenusingRPSsincethefade
marginwillbemuchhigherthananonACMspeedsetting,preventinglinklossand
subsequentreroutingduringweatherrelatedevents.

VLANTagging
GigaPlussupportstaggedpacketswithVLANIDsrangingfrom04089.Thelastseven
VLANIDsareusedinternallyasdescribedinthePortMappingSectionbelow.IfInBand
Management(IBM)isused,themanagementtrafficcanbeconfiguredtohaveaVLAN
tagtoallowtheswitchinternaltothesystemtoidentifypacketsinthedatastreamand
directthemtotheCPUforprocessing.TheVLANIDformanagementisuserspecified
usingtheibmcommand,withafactorydefaultVLANIDof4085.Itisrecommendedthat
themanagementtrafficbetaggedwiththehighestprioritysettingtoensurethatinthe
eventofnetworktrafficsaturation,themanagementtrafficwillhaveprecedence(See
ClassofServiceSection).UntaggedIBMisalsosupportedinFirmwarerelease2.0and

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

44

higher,butthereisnoguaranteeofprioritizationwhenthetrafficisonthesameport
andtheusertraffic.
QinQSupport:GigaPlussupportsQinQ,however,duetotheportmappingfeature
beingenabledbydefault,theoperatormustdisabletheportmapping.SeethePort
Mappinganddiscussiononsmart_modebelowformoreinformation

PortMapping(802.1q)
Theportmappingfeatureisafixedsettingandprovidesanadditionalamountofdata
securitysincetrafficontheindividualEthernetportsissegmentedandisolatedfrom
trafficonotherEthernetports.PortmappingisimplementedbyusingfixedVLANtags
internaltotheGigaPluslink.WhenEthernettrafficarrivesinaport,itmaybetaggedor
untagged.BothtaggedanduntaggedpacketsaretaggedwithanadditionalVLANTag
dependingonwhichporttheyarrivedatasfollows:
GE1:GigE10/100/1000BaseTport:VLANID4091
GE2:GigE10/100/1000BaseTport:VLANID4092
GE3:GigESFPport:VLANID4093
GE4:GigESFPport:VLANID4094
Attheotherendofthelink,theinternaltagsareremovedandtheoriginalpacketsare
sentoutunaltered.EssentiallytheGigaPlusisperformingdoubletaggingonpackets
thathavealreadybeentagged.
Portmappingisactivewhensmart_modeison.

QinQ/DoubleTaggingandsmart_mode
Iftheoperatorwishestosendpacketsthatarealreadydoubletaggedthroughthelink,
thensmartmodemustbedisabled.Withsmart_modeoff,alltrafficcominginonGE1
willappearatBOTHGE1andGE2portsonthefarend.Smart_modemustbeenabled
onbothendsofthelinkanditisrecommendedthatonlyoneofthetrafficportsGE1or
GE2beutilizedateachend.Oneaddedbenefitofsmart_modebeingoffisthatthelink
canactasamediaconverter.SideAofthelinkcanbecopperRJ45andsideBcanbe
GigEfibersingleormultimode.Themediaconversionwillonlyworkfor1000BaseT,as
thefiberinterfacedoesnotsupport10/100BaseTmodes.Itisrecommendedthatboth
portsbesettothesamespeedandduplexatbothendsofthelink.
InBandManagement(IBM)withVLANtaggingwillnotoperatewiththesmartmode
turnedoff.OutofbandmanagementandIBMwithVLANtaggingoff(SWV2.0)willstill
beavailableaswhenSmartModeisoff.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

45

ClassofService(802.1p)
GigaPlushasClassofServicecapabilitiesthatprovidepriorityfordifferenttypesof
trafficacrossthelink,whentheCOSbitsintheVLANtagonincomingEthernettraffic
areset.
Thetrafficcanbeclassifiedinto8priorities(07basedontheVLANtagCOSbits).Thisis
doneexternaltotheGigaPlusunitusingaswitchorapplicationtosettheprioritytag
field.OncethetaggedtrafficwithCOSprioritybitssetarrivesintheGigaPlusEthernet
port,theinternalswitchwillperformprioritizationonthetrafficbymappingittooneof
8queues.
The8queuesareFIFOsthatareemptiedintoasingledatapipegoingintothemodem
andsubsequentlyovertheair.Theschedulingofthequeuetrafficintothemodemdata
pipeisstrictpriorityfollowingthefollowingrule:
COSQ7>COSQ6>COSQ5>COSQ4>COSQ3>COSQ2>COSQ1>COSQ0

ThisruleessentiallymeansthatthesystemwillemptyCOSQ7beforesendingany
COSQ6packetsacrossthelink,andifbothCOSQ7andCOSQ6areemptythenCOSQ5
packetswillbesent,etc.
Thedefaultprioritymappingofthepacketwillbesetasfollows:

COSpriority0COSQ0,LowestPriorityQueue
COSpriority1COSQ1
COSpriority2COSQ2
COSpriority3COSQ3
COSpriority4COSQ4
COSpriority5COSQ5
COSpriority6COSQ6
COSpriority7COSQ7,HighestPriorityQueue

Thesedefaultmappingscanbechangedwiththecoscommand,allowingthepacketsto
bemappedintoanyoneofthe8queuesbasedontheCOSbitintheVLANtag.

PortPriority
TheportpriorityfeatureallowsforuntaggedtrafficarrivingintoeachEthernetportto
haveprioritylevelassignedtoit.Ifthearrivingtrafficisalreadytaggedthenthattag
prioritylevelwillbehonoredovertheportpriority.Theportprioritysettingwill
determinewhichporttrafficisforwardedintheeventofmoretrafficcomingintoallthe
portsthanthecapacityofthesystemcanhandle.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

46

Portprioritycanaugmentportratelimiting,especiallyinwhenACMisactiveandthe
linkhasdownshiftedtoalowermodulation.Theportcommandisusedtosettheport
priorityforeachport.

PortRateLimiting(Ingress)
Theportratelimitingfeatureisusedtorestricttheingresstrafficrateonaspecific
Ethernetport.ThisisusefulforServiceLevelAgreements(SLAs)whenbothportsofthe
GigaPlusarebeingusedtosupplytwocustomersandthechannelcapacityislimitedto
lessthanthesumofthecapacityofthetwoEthernetports.
Forexample,ifbothportsaresetto1000BaseT,andtheRFchannelcapacityis375
Mbps,settingGE1toratelimitof125MbpsandGE2toaratelimitof250Mbpswill
alwaysguaranteethatbothusershavethebandwidthofthechannelreservedforthem.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

47

4.0 LinkManagement
Thissectiondescribesthevariouswaystomanageandmonitorthehealthand
performanceoftheGigaPlusmicrowavebackhaullink.

Overview
TheGigaPluscanbemanagedthroughthefollowingmethods:

GraphicalUserInterface(GUI):

WebBrowser:Remoteaccessviainbandandoutofbandmethodswith
view/configurationlevelaccess(singleuser+password)usinganystandardweb
browsersuchasInternetExplorer,Chrome,Firefox,andSafari.

CommandLineInterfaces

SSHEncryptedremoteaccessviainbandandoutofbandmethodswith
separateviewandconfigurationlevelaccess(passwordprotected)

TelnetRemoteaccessviainbandandoutofbandmethodswithseparateview
andconfigurationlevelaccess(passwordprotected)

ConsoleLocalAccessusingaserialcableforbenchconfigurationwithseparate
viewandconfigurationlevelaccess(passwordprotected).

SNMPRemotecontrolandmonitoringviainbandandoutofbandmethods
usinganythirdpartyNetworkManagementSoftware(NMS).SeeAppendixDfor
detailsontheMIBandSNMPobjects.StandardMIBIISystemLeveland
EnterpriseMIBBlocksaresupportedwithmonitoringforallmajorlinkhealth
andtrafficrelatedmetrics.

DefaultIPAddress

ThefactoryconfigurationforIPaddressis192.168.100.100forallunits,andtheIBM
defaultaddressis172.16.1.1fortheAsideunitand172.16.1.2fortheBsideunit.

DefaultPasswords

Thedefaultpasswordsareshowninthetablebelow:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

48

Accessmode

Username

Password

CLIViewMode

admin

trango

CLIConfigMode

N/A

trango

CLIDebugMode

N/A

N/A

WebInterface

admin

trango

SNMPReadCommunity

N/A

public

SNMPWriteCommunity

N/A

private

SNMPTrap

N/A

trapstr

Table11DefaultLoginPasswords

GraphicalUserInterface(WebBrowser)
ToaccessthebrowserinterfacesimplyopenyourWebbrowserandentertheIPaddress
oftheradio.Aloginwindowwillpopup,requiringausernameandpassword(Figure
10).EnterthedefaultormodifiedusernameandpasswordthenpressOK.EitherHTTP
orHTTPSmaybeused.

Figure12WebBrowserLogin

ThefirstpagetodisplaywillbetheSystemInfoPageasshownintheImagebelow:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

49


Figure13SystemInfoPage
ThemainformatoftheGigaPlusWebInterfaceisshowninFigure11above.Thelayout
isdesignedtoallowtheoperatortoviewthecurrentlinkstatusonallpages.Theleft
sideofthedisplayshowsvariousfoldersorganizedbyfunction.Eachfoldercanbe
openedandexploredforthevarioussubpagesbysimplyclickingonthefolders
themselves:
NavigationBar:Thenavigationbartheleftshadedareacontainingthefunctional
folders.Thenavigationbarcontainslinktothefollowingfolders:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

50

RadioSettings:TheessentialRadioLinksetupparameters,TX/RXfrequency,
transmitterpower,speedandmodulation,aswellasthecapacitylicenseare
foundhere.Settingsfor1+1failoverarefoundhere.

NetworkSettings:TheessentialNetworksetupparameters,suchasIPaddress,
IBMsetup,andSNMPsetuparelocatedhere.

SystemStatus:Showsmostofthebasicconfigurationparametersoftheradio,
includingmodelsandserialnumbers,alongwiththecurrentlinkstatusincluding
PLLlocks.

SystemStatistics:CounterinformationonallinterfacesRF,Fiber,andGigEis
displayed.Thesestatisticsarerefreshedautomatically.

Diagnostics:Thisfoldercontainspagesthatshowcurrentsystemsettings,the
systemlogwhichrecordsalltheeventsandusersettings,andaspecial
diagnosticexportfunctionthatproducesatextfileforTrangoTechSupportto
usewhentroubleshootingisrequired.Thisfolderalsohasapagetocontrolthe
loopbackfunctionandantennaalignmentmodewhichincreasestheupdaterate
fortheantennaRSSIvalues

UserSetting:Usercanchangetheconfigpasswordandenterthelicense
upgradekeyforhighercapacity.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

51

CommandLineInterface(CLI)usingSSH,TelnetorConsole
Alltypicalradiofunctionscanbemanagedviathebrowserinterface,buttheCommand
LineInterface(CLI)hasadditionalfunctionalitythatfacilitatesinstallationand
troubleshooting.
TheCommandLineInterfacehas3nodes:View,Config,andDebug.Loggingintothe
radioviaCommandLineInterfaceiscoveredherebriefly,andacompletelistingofall
CLIcommandsisprovidedinAppendixA
LoggingintotheradioviaCommandLineInterfaceiscoveredherebriefly.Acomplete
listingofallCLIcommandsisprovidedinAppendixACommandLineInterface.

LaunchTelnet
Openacommandprompt(DOS)sessiononyourPC(WindowsStarticonandselect
Run).OpenaTelnetsessionbytyping:
telnet [ip address of radio]

Example:
C:>telnet 192.168.100.100

OnceattheCLIloginprompt,typeintheloginandpressenter,thenthepasswordand
pressenter.
CLI login: admin
Password: (No characters will be display during input)
Trango System:
v1.0.0

TrangoLINK GigaPlus Command Line Interface

(CLI-view)#

Iftheincorrectpasswordisenteredduringlogin,thesystemwillallowtwomoretries
beforeterminatingatelnetsession.Anewsessionwillneedtobeopentotryagain.
ToterminateaCLIsession(TelnetorConsole)simplyclosetheconsolewindow.ACLI
SESSIONCANALSOBETERMINATEDFROMTHEDEBUGNODEWITHEXITCOMMAND.

ViewNode: (CLI-view)# promptallowsviewlevelonly,andnoparametersofthe


radiolinkcanbechanged.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

52

ConfigNode: (CLI-config)#, Thisnodeisaccessedbytypinginthecommand


config fromtheviewnode.Thesystemwillpromptforapasswordandafter
successful authentication,theconfignodeisenabled.Allconfigurationsettingsare
changedwithintheconfignode.
Anycommandenteredwithoutanyparametersreturnsthecurrentconfiguredvalues
similartoviewnode.
Mostconfigurationchangesareappliedimmediatelyanddonotrequireareboot.All
configchangesmustbesavedtoFLASHmemorybyissuingthe config save
command.Thiscanbedoneafterallthechangesdesiredaremadewithinasingle
session
Iftheconfigurationisnot saved,thesystemwillrestorethelastsavedsettingsafter
reboot.

ALLCONFIGURATIONCHANGESHAVETOBESAVEDTOFLASHINORDERTOBE
PERSISTENTACROSSAREBOOT.ASINGLECONFIGSAVECOMMANDWILL
SAVEALLCONFIGURATIONCHANGES

Theoperatorcangobacktotheviewnodebyusing the exit commandfromthe


confignode.

Example:
CLI login: admin
Password:
Trango System:
v1.3.0

TrangoLINK GigaPLUS Command Line Interface

(CLI-view)# config
Password:

(CLI-config)#
(CLI-config)#exit
SUCCESS
(CLI-view)#

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

53

TheCommandLineInterfaceskeepsahistoryofcommandsused,pressingtheuparrow
willdisplaypreviouscommandsused.TheCLIcansupportsautocompleteofa
commandbeingtypedbypressing<tab>key.Ifacommandispartiallytypedfollowed
immediatelybya?itwilldisplayallrelatedcommands.

Example:
(CLI-config)#
targetrssi
tdm
telnetd
temp
tftpd
threshold
trap
(CLI-config)#

? (The ? will not be display)


Set target RSSI level for ATPC
Display TDM configuration
Enable/Disable telnetd
Display IDU and ODU temperature
Enable/Disable tftpd
Set the threshold for the radio parameters
Display snmp trap management information

TYPE?FORALISTINGOFALLCLICOMMANDS.

ChangingPassword
Thedebugandviewnodesharethesamepassword.Theconfignodehasaseparate
password.Theviewanddebugmodepasswordischangedinthedebugmode.The
confignodepasswordischangedintheconfignode.UsetheCLIcommandpasswrdto
changethepassword.Theexamplebelowdemonstrateschangingthepasswordforthe
confignodetocontrol
Syntax: passwrd <newpassword> <newpassword>

Example:
(CLI-config)# passwrd control control (The password must be entered twice)

Ifthecommandisproperlyexecuted,thesystemwillreturnaSUCCESSandreturnto
theCLIconfigprompt.
Ifthepasswordislostandtheunitislocked,thepushbuttonontheaccesspanelcanbe
usedtoresetthepasswordanddefaultIPbacktothefactorysettings
ConsolePort
GigaPlusfeaturesaconsoleportwhichismultiplexedwiththeportforthe1+1hot
standbyoperation.If1+1hotstandbyisactivetheconsolecablecannotbeused.The
consoleportisusefulintheeventthattheunitcannotbeaccessedviaTCP/IP(HTTPor
Telnet).ATerminalEmulationprogramsuchasHyperTerminalorPuttycanbeusedto
accesstheradiosCLIviatheconsoleportasshowninFigure12.
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

54

Figure14ConsolePortSetting

SimpleNetworkManagementProtocol(SNMP)
TrangoLINKGigaPlussupportsSimpleNetworkManagementProtocol(SNMP)for
networkmanagement.Networkmanagementconsistsof4categories:
1. Configuration
2. Accounting
3. Alarm
4. Monitoring/Control
Thesecapabilitiesallowthenetworkoperatortoprovidesuperiorservicesthrough
highernetworkaccessibilityandintegratedaccountingsystem.UseofSNMPrequires
thecustomertohavealreadyimplementedaNMSorSNMPsoftwarepackage.
TheTrangoSNMPsolutionsupportsMIBII(systemonly)andtheTrangoproprietary
ManagementInformationBase(MIB).
UsersinterestedinusingtheSNMPfunctionalityshouldreviewtheentireTrangoLINK
GigaPlusMIB,foundinAppendixD,foracompleteunderstandingofitsfeatures.
ThefollowingisanoverviewofsomeofthemorecommonlyusedSNMPobjectsinthe
TrangoLINKGigaPlussystem.AcompletelistingcanbefoundinAppendixD.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

55

AcopyoftheMIBfilesforthecurrentfirmwareversioncanbeobtainedbycontacting
TrangoTechnicalSupport.
CommonObjectsforMonitoringandControl

GigEBandwidthMonitoring

gigeEth1InOctets:NumberofoctetsofpayloadreceivedonGigEport1(copper).

gigeEth2InOctets:NumberofoctetsofpayloadreceivedonGigEport2(copper).

gigeEth3InOctets:NumberofoctetsofpayloadreceivedonGigEport3(SFP).

gigeEth4InOctets:NumberofoctetsofpayloadreceivedonGigEport4(SFP).

gigeEth1OutOctets:NumberofoctetsofpayloadtransmittedonGigEport1
(copper).

gigeEth2OutOctets:NumberofoctetsofpayloadtransmittedonGigEport2
(copper).

gigeEth3OutOctets:NumberofoctetsofpayloadtransmittedonGigEport3
(SFP).

gigeEth4OutOctets:NumberofoctetsofpayloadtransmittedonGigEport4
(SFP).

RFMonitoring

rfInOctet:NumberofoctetsofpayloadreceivedfromtheRFport.

rfOutOctet:NumberofoctetsofpayloadtransmittedtotheRFport.

rfEthernetInPackets:NumberofoctetsofpayloadreceivedfromtheRFport.

rfEthernetOutPackets:NumberofEthernetpayloadpacketstransmittedtothe
RFport.

rfRSSI:TheReceiveSignalStrengthIndicationindBmtheunitreceivesfromthe
ODU.CommonlyreferredtoasReceiveSignalLevel(RSL)

LinkStatusTraps
Varioustrapsaredefinedasfollows:

trapReboot:trapistriggeredwhentheunitisrebooted.

trapStartUp:trapistriggeredwhentheunitbootsup.

trapBackupLink:traptriggeredwhenthebackupstatuschanges.

trapBackupTakeover:ThetrapistriggeredwhentheBackupunithastakenover.

trapModemLockThistrapwillinformyouwhenthereisachangetothelink
lock.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

56

trapDownShiftThistrapwillinformyouwhenthemodulationoftheradiohas
shifteddowned.

TrangorecommendsmonitoringRSSI,MSE,EthernetTraffic(gigeEthOctets),Temp,and
modemlockasaminimumforthoroughmonitoringofthelink.Additionalobjectsand
trapscanbeaddedtothemonitoringsoftwareasrequired.PleasereviewAppendixD
MIBforacompletelistingofMIBObjectsandTraps.
UnderstandingandfamiliarizationofSimpleNetworkManagementProtocol(SNMP)
conceptsandsoftwareplatformsarerequiredtoutilizeSNMPmanagementofthe
TrangoLINKGigaPlussystem.
DuetothelargenumberofprogramsavailableforSNMP,Trangodoesnotprovide
supportofSNMPsoftwarepackagesorNMSsystems.Somecommonitemstotrywhile
havingissuesmonitoringspecificOIDsare:

ProperlyloadtheMIBsintoyoursoftware

Tryaddinga.0attheendoftheOIDstring

FirmwareUpgrade
ThefirmwareontheTrangoLINKGigaPluscanbeupdatedtoanewerversionthrough
IBMorOBMEthernetPorts.Afirmwarereleaseconsistsofuptotwofileswhich
containstheappropriatesoftwarefilesthatareloadedontotheIDUandODU:
IDUOSImageFirmwareFile

<idu_GigaPlus_<version>.tar.gz>

ODUImageFirmwareFile

<odu_fw.bin>

IfonlytheIDUfirmwarewaschangedthentheODUfirmwaredoesnotneedtobe
updated.
Beforebeginningtheupdateprocedure,becertainthatallrequiredfileshavebeen
downloadedtoaneasilyaccessibledirectoryonyourlocalharddrive.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

57

UpgradeProcedureTFTP

ALWAYSCONSULTTHEUPGRADEINSTRUCTIONSTHATAREINCLUDEDWITHANEWFIRMWARE
RELEASEASCERTAINFILESMAYNOTBEREQUIREDFORANUPGRADE.

1) Placethefirmwarefilesinaneasilyaccessibledirectorypathonyourcomputer.
2) TelnetintotheradiobyClickingonStartmenuthenRUN.Thefiguresusethe
defaultIPaddress;youmustusethecorrectIPaddressfortheTrangoLINK
GigaPlus.

Figure15WindowsStart&Telnet

3) Attheloginenteryourusernameandpassword.Theusernameisadminand
defaultpasswordistrango
4) Enterconfignodebytypingconfigandenteringyouwriteaccesspassword.
Thedefaultconfignodepasswordistrango
5) Enablethetftpdaemonusingthetftpdcommandasshownbelow.

Loginas:admin
Password:
TrangoSystem:TrangoLinkGigaPLUSCommandLineInterfacev1.3

(CLIview)#config
Password:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

58

(CLIconfig)#

(CLIconfig)#tftpdon
tftpd:on
SUCCESS
(CLIconfig)#

6) Openacommandprompt(orotherCLIinterface)windowonthePCwherethe
newfirmwareisbeingstoredandaccessthedirectorythatyouextractedthe
firmwarefiles.

C:\CDFirmware
C:\Firmware

7) UsingtheTFTPcommandlinetool,uploadthefirmwarefile.Thetftpsyntaxand
anexamplearebelow.

TFTP[i]host[GET|PUT]source[destination]

C:\firmware>tftpi192.168.100.100putidu_gigaplus_v13.tar.gz
Transfersuccessful:1951744bytesin15seconds,130116bytes/s

8) Oncethefilehasbeentransferredsuccessfully,logbackintotheunitandapply
theupdatesintotheFLASHmemoryusingthebootimageupgradecommand
fromtheconfigmode.Eachfirmwareneedstobeupgradedontheunitusingthe
bootimageupgradecommand.

(CLIconfig)#
(CLIconfig)#bootimageupgradeidu

NOTE:THEBOOTIMAGEUPGRADECOMMANDMUSTBEALLOWEDTO
COMPLETEBEFORETHESYSTEMISREBOOTED.IFTHESYSTEMISREBOOTED
DURINGTHEWRITINGOFTHEIMAGETOFLASH,THEFLASHMAYBECOME
CORRUPTWAITFORTHESUCCESSINDICATIONBEFOREPROCEEDING.
IftheODUfirmwarewasalsobeingupgraded,theODUfilewouldbetransferred
totheGigaPlusODUusingthesamemethodastheIDUfile.Afterloadingthe
file,thebootimageupgradeoducommandwouldbeusedtowriteittoFLASH.
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

59


(CLIconfig)#bootimageupgradeodu

9) Arebootoftheradioisrequiredtoloadthenewimageafterupgrade

(CLIconfig)#reboot

Theupgradetimevariesdependingupontheimagesandthesizeoftheimage.
ThefirmwarecanbeverifiedbyloggingintotheradioviatheCLIthroughtheversion
commandorWebbrowserversionpageundertheFirmwareVersionsection.
TheCurrentfirmwareisthecurrentlyrunningfirmware.Thefirmwarewhichwas
replacedwillbelocatedinthepreviousimages.
UpgradeProcedureFTP
ToperformthefirmwareupgradeusingFTP,usetheftpcommandtoloadtheimages
intomemory,thenthebootimageupgradecommandsjustaswiththeTFTPmethod.
TheFTPmethodismuchfasterandhasbuiltinerrorchecking.
AllthatisneededistheIPaddressoftheftpserver,ausername/password,andthe
filenametobeuploaded.Thenewfiletobeuploadedshouldbeplacedontheserver.
Theftpserverwillpromptforthepasswordbeforeallowingaccess.
1) Putthenewsoftwarefilesontheftpserverusingtheftpputcommandfroma
localcomputer(thesecommandsarenotdonefromtheTrangoequipment).
ftp>put<sourcefile><destination>:
The<source>willbethefilenameonly.The<destination>willincludebothpathandfile
name.
2) Afterputtingthefileontotheserver,logintotheGigaPlusandruntheftp
commandfromthecommandlineasfollowstoopenaccesstotheserver:
ftp<server_ip><user_name>
password:xxxxxxx

Ifpromptedforthepasswordmultipletimes,checktheconnectivitytothe
serverbypingingtheFTPserverIPaddressfromthedebugprompt.
3) Next,getthefilefromtheFTPserverbytypingthegetcommandfromtheftp
prompt.
ftp>get<file_name>

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

60

4) Logoutoftheftpsession
ftp>logout:logoutofftpsession.
5) Runthebootimageomuand/orbootimageoducommandasrequired.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

61

CapacityUpgrades
TheGigaPlusspeedcapacityisstandardat100Mbps.Toupgradethecapacity,an
alphanumerickeywillberequired.ThiskeycanbepurchasedfromyourTrangosales
representative.
ToupdatethecapacitykeyfromtheWeb,copyandpastethekeyintotheSpeed
LicensefieldontheLinkSetupPage.Clickthesubmitbutton.Ifthelicenseisaccepted,
thewordEnablewillbedisplayedasshownbelowandreplacetheblankfield.

Figure16CapacityUpgradeinLinkSetupPage

Thecapacitykeycanalsobeenteredusingthelicensecommandfromthecommand
lineinterface.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

62

5.0 LinkPlanning
Thissectiondescribestheprocessthatoccursbeforeinstallingandsettingupan
GigaPlusmicrowavebackhaullink

Frequency/PathPlanning
Mostmicrowavelinksuselicensedspectrumthatrequiresthirdpartycoordinationto
ensureminimalinterferencewilloccurtonearbylicensedspectrumusers.Toensure
success,apathanalysismustbedoneforeachlinkthatisbeingconsidered.Antenna
heights,systemgain,rainregionandterraindataareevaluatedtodeterminethe
reliabilityofthelinkovertimeandchangingweather.
Trangowillrunpathanalysisforitscustomersusingindustrystandardsoftware,
evaluatedifferentequipmentoptionstoachievethecustomergoals,andassistthe
coordinationprocess.

SiteSelection
AfterthePlanningphaseiscomplete,itisessentialthattheproposedsitebephysically
evaluatedbytheoperatortoensurethatnobuildingsorvegetationhascrossedintothe
Fresnelzonethatwouldaffectoperationalreliability.
Itisnotuncommonfortallbuildingstobelocatedinwhatwouldotherwisebeaperfect
nonblockedlineofsightpathbasedonterraindata,buttoooftenthisisdiscovered
whentheinstallationisbeingperformed.
Thesitemustalsobeevaluatedforpowerandshelterprovisions.

Licensing
Licensingofspectrumistypicallydoneonanindividualpathbasis.IntheUS,theFCCwill
grantlicensesfor11yearsforpathsthatdonotinterferewithotherusersafterthe
coordinationandfeeshavebeenpaid.
ContactTrangoformoreinformationontheabovetopics.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

63

6.0 Installation
ThissectiondescribestheinstallationtoensurethattheGigaPlusunitsarecorrectly
installed.Failuretofollowtheseproceduresmayresultindamagetotheequipment
andvoidthefactorywarranty.

Safety
Installingmicrowaveequipmentcanbedangerous.Pleasetakethefollowing
precautionswheninstallingorperformingmaintenanceontheequipment.

EquipmentProtrusions:Theequipmenthasbeendesignedtobefreeofunnecessary
protrusionsorsharpsurfacesthatmaycatchorotherwisecauseinjuryduringhandling.
However,alwaystakecarewhenworkingonoraroundtheequipment.

LaserandFiberOpticCableHazards:TrangofiberopticSFPModuletransmittersare
IEC608251/21CFR10401ClassIcompliantandpresentnodangertopersonnelin
normaluse.However:Donotlookintoactiveunterminatedopticalportsorfibers.If
visualinspectionisrequiredensuretheequipmentisturnedoffor,ifafibercable,
disconnectthefarend.Followthemanufacturer'sinstructionswhenusinganoptical
testset.Incorrectcalibrationorcontrolsettingscouldresultinhazardouslevelsof
radiation.Protect/coverunconnectedopticalfiberconnectorswithdustcaps.
Placeallopticalfibercuttingsinasuitablecontainerforsafedisposal.Barefibersand
fiberscrapscaneasilypenetratetheskinandeyes.

LiftingEquipment:BecarefulwhenhoistingorliftingtheODUoritsantennaduring
installationormaintenance.TheGigaPlusHPODUisnominally12lbs.However,
antennaswiththeirmountinghardwarecanweighinexcessof100kg(220lb)and
requirespecializedliftingequipmentandanoperatortrainedandcertifiedinitsuse.

ProtectionfromRFBurnsTrangoODUs:TrangoGigaPlusODUsdonotgenerateRF
fieldsintenseenoughtocauseRFburns,however,installers/operatorsshouldcomply
withthefollowingcautions:
1) Itishazardoustolookintoorstandinfrontofanactiveantennaaperture.Do
notstandinfrontoforlookintoanantennawithoutfirstensuringtheassociated
transmitterortransmittersareswitchedoff.
2) DonotlookintothewaveguideportofanODUwhentheradioisactive.

ProtectionfromRFBurnsTowerSite:WhentheGigaPlusODUistobeinstalledwhere
existingantennasarelocated,avoidexposuretopotentiallyharmfullevelsofRF
radiationfromtheseantennasby:
1) DeterminingtheRFexposurerisk.Ifnecessaryaskthestructure/towerowneror
operator.Whennecessary,wearaprotectivesuitorhavethetransmitter(s)
switchedoffforthedurationoftheinstallation.
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

64

2) Donotstandinfrontoforlookintoanyantennas.

SafetyWarnings:Whenapracticeorprocedureposesimpliedorpotentialharmtothe
userortotheradioequipment,awarningisincludedinthismanual.

AirflowRequirements:Installationsmustbemadesotheairflowrequiredforsafeand
correctoperationofTrangoequipmentisnotcompromised.FortheGigaPlusODU,
unobstructedairpassagemustbemaintainedtoallsidesoftheunit.FortheGigaPlus
IDU,thebackoftheunitmustbekeptcleartoallowthefantooperateproperly.

CircuitOverloading:WhenconnectingtheGigaPlus,determinetheeffectthiswillhave
onthepowersupply,circuitprotectiondevices,andsupplywiring.CheckGigaPlus
powerconsumptionspecificationsandthesupplycapabilityofthepowersupplysystem.
Thischeckofcapacitymustextendtothedcpowersupplyandnotjusttoan
intermediateconnectionpoint.

PowerSupplyEarthing:48Vpowersupplyearthmustbeconnecteddirectly
toabondingjumperfromanearthingterminalbarorbus.

ElectrostaticDischarge(ESD):ESDcandamageelectroniccomponents.Evenif
componentsremainfunctional,ESDcancauselatentdamageand/orprematurefailure.
AlwayswearproperESDgroundingstrapswhenhandlingortouchinganyPCB
assemblies.ConnectyourESDgroundingstraptothegroundconnectorontheODUor
IDUunitsasapplicable

FiberOpticCables:Handleopticalfiberswithcare.Keeptheminasafeandsecure
locationduringinstallation.Donotattempttobendthembeyondtheirminimumbend
radius.Protect/coverunconnectedopticalfiberconnectorswithdustcaps.

GroundConnections:Reliablegroundingofthesystemmustbemaintained.Referto
instructionsinthismanualforgroundingoftheODU,ODUcable,lightningsurge
suppressor,andIDU.

LightningSurgeSuppressor:TheGigaPlusIDUtoODUIFcablemustbefittedwithsurge
suppressorstopreventdamagetoequipment.Seetheinstallationsectionforfurther
details.

MainsPowerSupplyRouting:GigaPlusDCpower,T1/E1,Ethernetdataand
managementcablesarenottoberoutedwithanyACmainspowerlines.Theyarealso
tobekeptawayfromanypowerlineswhichcrossthem.

AmbientTemperature:TheambienttemperaturerangefortheGigaPlusODUis40to
+65Celsius,and5to+55CelsiusfortheIDU.Toensureoperationandtomaximize

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

65

longtermcomponentreliability,ambienttemperaturesmustnotbeexceeded.
Operationalspecificationcomplianceisnotguaranteedfortemperaturesoutsidethis
range.

MechanicalLoading:WheninstallingtheGigaPlusODUandantenna/remotemounton
atowermountorbuilding,ensurethemountissecurelyanchoredfirstandcansupport
thefullloadoftheradiounitandantenna.Ensurethattheadditionalloadingofan
GigaPlusODUwillnotcauseanyreductioninthemechanicalstabilityofthemount.

PowerSupplyConnection:TheGigaPlusIDUhasthepositivepinonitsdcpowersupply
connectorconnecteddirectlytothechassis,whichisinturnconnecteddirectlytothe
earthgroundthroughthetowerleg.TheGigaPlussystemmustbeusedwitha48Vdc
powersupplywhichhasapositiveearth;thepowersupplyearthconductoristhe
positivesupplytotheIDU.

1) Theremustbenoswitchingordisconnectingdevicesinthisearthconductor
betweenthedcpowersupplyandthepointofconnectiontoaGigaPlussystem.
2) ThepowersupplymustbelocatedinthesamepremisesastheGigaPlussystem.
3) AllwiringwhichiscarryingpowertotheGigaPlusIDUfromthepowersupply
mustbelargerthan18AWGandshouldbetwistedtoreducenoiseintotheIDU.

PowerSupplyDisconnect:Anappropriatepowersupplydisconnectdeviceshouldbe
providedaspartofthebuildinginstallation.

RackMountTemperatureConsiderations:IftheGigaPlusIDUisinstalledinaclosedor
multiunitrackassembly,theoperatingambienttemperatureoftherackenvironment
maybegreaterthanroomambient.Themaximumambienttemperatureof+55Celsius
appliestotheimmediateoperatingenvironmentsurroundingtheIDU,whichifinstalled
inarack,istheambientwithintherack.

RestrictedAccess:TheGigaPlussystemmustbeinstalledinrestrictedaccesssites.The
PoEunitandassociatedpowersupplymustbeinstalledinrestrictedareas,suchas
dedicatedequipmentrooms,closets,cabinets,orthelike.Accesstothetowerand
ODU/antennalocationmustberestricted.

Note:ForUSA:InrestrictedaccessareasinstalltheGigaPlussysteminaccordancewitharticles11026
and11027ofthe2002NationalElectricalCodeANSI/NFPA70.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

66

InstallationProcess
Thestandardprocedureforinstallingtheequipmentisasfollows:
1) Installantennaperantennainstallationmanual
2) InstallGigaPlusPowerSupplyandIDUinrack
3) InstallODUonantennaatbothends
4) InstallIFcablingandsurgesuppressors
5) Alignantennas
6) Proceedtocommissioning.
CAUTION:GigaPlushasnouserserviceableparts.Onlyfactorycertifiedpersonnel
shouldmakeanychangesorrepairstotheunits.

PreparingforInstallation
Tools
Thefollowingtoolsarerequiredforinstallation:

AdjustableOpenEndedWrench
LMR400cable
NMaleconnectorforLMR400
LMR400stripppingtoolorrazorblade
LMR400cablecrimptool
#2Flatscrewdriver
#2PhilipsHeadscrewdriver
Stranded18AWGwireforpowerconnection
Stranded12AWGwireforODUandIDUgroundconnections
WireInsulationstrippersforgroundandpowerwire
Terminalcrimpersforgroundandpowerwire

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

67

GroundingOverview
GroundingoftheIFcableshouldbedoneatthebaseofthetowerandneartheODU
usinggroundingkitssuppliedbyTrango.Inaddition,lightningsurgesuppressorsshould
beusedtopreventdamageduetonearbylightningstrikes.AntennaandODUshouldbe
installedatleast10feetbelowthetopofthetowertopreventdirectlightningstrikes.
AGroundwireofAWG12orlargershouldbeusedandgroundedtoanEarthgrounded
towerlegorBusBarbeforeentryintotheshelter.Figure16showstheoverallground
design.

Figure17SiteBasedGroundingDiagram

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

68

PowerSupplyInstallation
TheGigaPlusrequiresa48VoltpowersupplytopowerboththeIDUandtheODU.
Trangorecommendsthe48VDC,1Urackmountpowersupply(part#PSUPPLY1U
48).ThispowersupplycansupportuptotwoGigaPlusIDUsandODUsandisshown
below:

Installthepowersupplyinatemperaturecontrolledshelterorstandard19inchrack
usingtheholesprovided.
NOTE:Ensurethatonlya48VoltSupplyisusedandthatthewiringiscorrect.Ifa+48
VDCsupplyisusedandtheEarthgroundiswiredtothenegativeterminalshownin
thefigure,permanentdamagetotheunitmayoccur.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

69

AntennaInstallation
Antennasaretypicallyinstalledandarecoarsealignedusingeithervisuallyorwiththird
partyequipment.Alternatively,someoperatorsprefertoinstalltheradioequipment
ontotheantennapriortoinstallingtheantennaontherooftoportower.
Consultthespecificantennamanualfortheantennabeingusedfordetailedinstallation
instructions.
TheLinkConfigurationsectioncoversthealignmentoftheantennas.

InstalltheIDU
TheIDUissuppliedwithmountingbracketsandscrewsforinstallationintoastandard
19inchrack.TheIDUisprovidedwithagroundlugthatshouldbeconnectedtotherack
groundwithashortlengthofstrandedcopperwiretoensurealowimpedancepathto
ground.WhentighteningscrewsfollowtherecommendedtorqueintheTablebelow

Screw or Nut
Torque (in-lbs)
Size
4-40
6
6-32
12
8-32
22
10-32
37
-20
65
Table12RecommendedTorque
AsingleIDUwiththeRackEarsinstalledisshownintheFigurebelow.Itis
recommendedtoalwaysinstalltheIDUontheleftsidetoreducethelengthofthe
groundingwiretotherack.

Figure18IDUwithRackEarsinstalled
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

70

Connectingpower
TheGigaPlusissuppliedwithathreepositionlockingterminalblockforconnectingthe
48VDCpowersupply.ThemiddlepositionisEarthGroundandtheoutertwopositions
are48VDC.SeetheFigurebelow.

Figure19PowerConnectiononFrontPanel
Althoughonlyoneofthe48VDCconnectionsisrequired,dualpowersuppliescanbe
usedtoprovideredundancybyconnectiontheleftpositiontoonesupplyandtheright
positiontotheothersupply.
Internaldiodespreventcurrentfromflowingthewrongdirectioninthecasethatoneof
thepowersuppliesshouldfail.Undernormaloperationthecurrentwillbedivided
betweenthetwosupplies.
Asmentionedpreviously,thepowersupplywiresshouldbetwistedtoimprovethe
noiserejectionofthesystem.
Thewiringusedshouldbetwostrandedcopperwiresofasizenosmallerthan18AWG.
Thewiresshouldbetwistedtogethertoreducesusceptibilitytonoise.Atleastoneturn
perinchisrecommended.Tightenthetwo#2screwstothechassisafterinstallationof
theconnectortopreventitfrompullingout.
48V(2positions)

Ground(+)

Figure2048VDCPowerConnectorWiring
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

71

FerriteInstallation
TheIDUshipswithaferrite(Figure21)toreducenoiseenteringtheunitthroughthe
powercable.Toinstalltheferrite,loopthepowercablethroughatleastonceandclose
theferrite.BesuretoinstalltheferriteascloseaspossibletotheIDUpowerplugas
showninFigure22toimprovethenoiserejection.

Figure21Ferrite

Figure22FerriteInstalled

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

72

1+1HotStandbyIDUInstallation
Theinstallationofthe1+1HotStandbyissimilartothe1+0installation,exceptthe
installationisrepeatedforthesecondstandbyunitwhichismountedintheracknextto
themainunit.Thedummypanelisremovedinthiscase.

CBLDATRIU3

Figure231+1HotStandby(IDUs)withCBLDATRIU3

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

73

HPODUInstallationonAntenna
TheODUportionoftheGigaPlusutilizesaslipfitconnectionthatmakesinstallation
simple.TheODUsarealldesignedtomounttoacircularwaveguideantennaor
combinerwiththeexceptionofthe6GHzmodels.
For7to40GHzmodels,simplyrotatingtheODUwillchangetheantennapolarization
beingused.

AntennaO
RingSeal

HPODU
Waveguide

Antenna
Circular
Waveguide
port

Figure24AntennatoHPODUSlipFitWaveguideconnection
AfterinstallingandsecuringtheantennatheHPODUcanbeinstalleddirectlyonthe
backoftheunit.First,determinewhichAntennapolarizationwillbeusedandensure
thatthepolarizationindicatorisatthetopoftheunit.
PolarizationIndicatorsTheletterVisdiecastontheODUhousingperimeterto
assistinmountingtheODUtotheantennainthecorrectpolarization.
ForverticalpolarizationtheVshouldbeatthetopoftheunitasshownintheFigure
below,andforhorizontalpolarizationtheVshouldbeatthesideoftheunit.TheIF
connectorshouldbepositionedtowardsthelowerrightforverticalandlowerleftfor
horizontalpolarization.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

74

Vpolarization
indicatorattop

Figure25PolarizationIndication
CovertheantennaOringwithsiliconegreasepertheAntennamanual.Failuretodo
thismayresultinadamagedOringandsubsequentdamagetoorwaterintrusioninto
theantennaorODU.
GentlyslidetheODUontotheantennaandclipthefourspringloadedlatchestothe
antennaclipsasshownbelow.Thelatchesshouldbeverysnugandclickintoplace.If
thereisdifficultyclosingthelatches,thencheckthewaveguidefordebrisorforeign
matteraroundtheperimeter.
Securethelatchesthathaveeyeletswithlocksifdesired.

Latchwith
Eyelet

Figure26Latch

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

75

ForHP06yyyyzzandHP06yyyyzzmodels,boththeantennasandradiosusea
rectangularwaveguideopeningonthesameslipfitdesign.Thestandardpolarizationis
suppliedasVertical.Tochangethepolarization,theantennamustbechangedfrom
verticaltohorizontalbyrotatingeithertheantennaortheantennawaveguideport.
Consulttheantennainstallationmanualformoreinformation.

IFCableInstallation
GigaPluscansupportupto1000footcablerunsbetweentheIDUandODU.
LightningMitigationRecommendationsAsshowninthegroundingdiagram,Trango
stronglyrecommendsinstallingLightningarrestorsataminimumtwopointsintheIF
Cablerouting:
1) Attheclosestpointoftheradiopossible
2) Attheentrypointtothebuildingorequipmentshelter
3) Foroptimumprotection,Trangorecommendsinstallingatevery
5075ft
Theseconnectionsshouldbesecuredtothetowerorpoleatapointwherethereall
paint/platinghasbeenremovedtoensurealowimpedancepathtoground.NOTE:
thereisnoguaranteethatuseofthesearrestorswillpreventLightningdamagetothe
radioorotherelectronics,butitisprudentsystemdesigntoaggressivelymitigatethe
effects.

CableLengthRecommendationsTrangorecommendsthattheIFCablebeinstalled
witha2ftserviceloopnexttoeachconnector(i.e.belowtheODU/LightningArrestor,
nexttotheIDU,etc.)toallowforreplacementterminationsinthefuture.

CableConnectivityTheIFCablecanbeconnectedtotheODUandIDUwithrightangle
Nadapters(femaletowardsthecableandmaletotheIDU/ODU)whichpreventthe
bendradius(minimum1inch)fromobstructingcabinetdoors.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

76


Figure27RightAngleNConnectorMount
CableDressRecommendationsProperlysecuringtheIFCabletothetowerorpole
structureisimportantsincepoorlydressedcablescanbeabradedbythefrictionofwind
actionandcableconnectioncanbedegradedovertimebythesamestresses.When
securingtheIFCabletothetowerorpole,Trangorecommendsusingtiewrapsthatare
UVresistant(black)tominimizedeterioration.Tiewrapsshouldbeatleastinwide
andpulledonlyastightasneededtosnugthecabletothestructure.Narrowtiewraps
orovertighteningatiewrapcancompromisetheinternalstructureofthecoaxand
degradeperformance.TheIFCableshouldbesecuredtothetowerormountingpoleat
leastevery3to6ftwithtiewrapsorotherapprovedmethods.HangerAssembliesand
CableClampsareofferedbytowercompaniesthatcanprovideanevenmorerigid
attachmentforhighwindenvironments.
CableTerminationsRobustcableandcableconnectionsareCRITICALtothelongterm
performanceofthelink.Anycompromiseinmaterial,connectionprecision,or
weatherproofingmayresultinproblemsthataredifficulttofaultisolateandonly
emergeafterthelinkhasbeenexposedtothenormalstressesoftemperature,rain,and
winds.
CableTypeTrangostronglyrecommendstheuseofqualityLMR400cableandtopof
thelineconnectorscomplimentedbywelltrainedinstallationpersonnelfollowing
manufacturersinstructions.Othertypesofcablemaynothaveadequateshieldingand
maycauseorreceiveoutsideinterference.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

77

WeatherProofingCabling
Itisimportanttoproperlysealeachantennaconnectiontoprotectagainstmoistureand
corrosion.TrangoSystemsrecommendsusingCoaxSealwhichshouldbeappliedover
theODUNTypeconnector.CoaxSealisagumliketapewhichisappliedbywrapping
aroundtheconnectorandthencompressed/moldedtoformasinglecohesive
protectivecoveringovertheconnector.
ToproperlyapplytheCoaxSealproductfirstwraptheconnector/caseasshownin
Figure28:

Figure28WeatherProofingofcable
Secondly,compresstheCoaxSealproducttomoldintoasingleprotectivecovering
(Figure29):

Figure29Completeweatherproofingofcable

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

78

1+1HotStandbyODUInstallation
Theinstallationofthe1+1HotStandbyODUisdoneusingacombinerwhichhastwo
latchmountpositionsformainandstandbyODUs,andthelatchandboltmountfor
connectingtotheantenna.TheODUsmaybeattachedtothecombinerfirstandthe
combinerboltedandlatchedtotheantennanextasshownbelow.TwoIFcablesmust
beruntoeachofthetwoIDUs.
TheODUsmustbemountedusingthesamepolarizationfor1+1hotstandbyoperation.
FormoredetailseethemanualfortheSMCXXXXcombinerfamily.

Figure30ODUsonSMCcombiner(1+1)

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

79

7.0 LinkConfiguration
Thissectiondescribesthestepbystepprocessofconfiguringalinkandmakingsureitis
workingproperlybeforeinstallingandputtinglivetrafficonthesystem.
Thissectioncoversbasiclinkestablishmentforasinglelink.Thissetupmaybedoneon
thebenchorinthefield.Itishighlyrecommendedthatthebasiclinksetupbedoneon
thebenchtoavoidproblemswheninstallingtheequipment.
Specialbenchtestsetupsthatprovidemountingandfixedorvariableattenuation
betweentheRFportsoftheunitscanbeobtainedfromTrangoforthispurpose.All
stepsgivenshouldbeperformedonbothendsofthelink.
IMPORTANTNOTE:IfthelinkwasfactorypreconfiguredatTrangobeforeshipment,
thissectioncanbeskippedsincethepropersettingsarealreadyinplaceinsidethe
radiounits.
OnlytheIPaddressesneedtobechangedandtheOpmodeneedstobeenabledat
bothends.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

80

WebBasedConfiguration
WebBased1+0Setup
TheWebinterfaceisthemostcommonlyusedwaytosetupalink.Astepbystepguide
isshownbelow.ToaccesstheBrowserinterfacefromtheOutofBandmanagement
port,simplyconnecttotheunitusingEthernetcabling,openawebbrowserandenter
theIPaddressoftheradiointotheaddressline.ThedefaultIPaddressis
192.168.100.100

Figure31WebInterfaceLogin
Step1:Entertheusernameandpassword
Aloginwindowwillpopup,requiringtheusertoenterusernameandpassword(See
Figure33).Enterthedefaultusernameandpassword(user:admin,password:trango)
andclickOK.

Figure32WebLoginwithPassword

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

81

Oncetheusernameandpasswordareauthenticated,theSystemInfopagewillbe
displayedasshownbelow:

Figure33SystemInformationPage
Step2:SettheIPaddresses
a. ClickontheNetworkSettingsfolderandIP/IBMconfigurationpage.Set
theIPaddress,Subnet,andGatewaytotheaddressthatisdesiredforthe
OutofbandManagementPort.ClickSubmit.AtthispointtheWeb
sessionwillterminateandtheoperatormustloginagainusingthenewIP
address.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

82


Figure34IPConfigurationPage

b. SettheIPaddress,Subnet,andGatewaytotheaddressthatisdesiredfor
theOutofbandManagementPort.ClickSubmit.
AtthispointtheWebsessionwillterminateandtheoperatormustloginagainusingthe
newIPaddress.

Step3:SettheRadiolinkparameters
Alltheparametersshouldmatchthosesubmittedandapprovedbythelicensingagency.
c. SettheOdupowertoOnifitisnotalreadyon.
d. TurntheOpmodetoOffifitisnotalreadyoff.
e. SettheTXfrequency,bandwidth,modulationandtransmitterpower,
thenclickLinkSetup.Ingeneral,theFreqDuplexdoesnotneedtobe
changedunlessanonstandardspacingisbeingused.
f. Afterbothendsofthelinkaresetup,turntheopmodebuttononto
establishthelink.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

83

DonotadjusttheFailoversettingsunless1+1isdesiredSeetheSectiononsettingup
1+1fordetailonthis.

Figure35LinkSetupPage

Thelinkshouldnowbeestablishedbetweenthetwosides.TheActiveLinkindicators
willturngreenandtheRSSIandMSElevelswillchangeaccordingtothelinkdistanceor
attenuationused(bench)
ClicktheConfigSavebuttonatthelowerleftofanywebpageThismustbedoneon
bothsidesofthelink.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

84

WebBased1+1Setup
The1+1Setupisanextensionofthebasic1+0setup.1+1hotstandbyutilizestwo
GigaPlusunitsconnectedtoacombinertoallowsharingofanantennaateachendof
thelink.Oneoftheunitsateachendisthemain(active)unitandtheotherunitisin
standby,whichmeansthatitisreadytotakeovershouldtheactiveunitfail.
Thissectionassumesthatthephysicalinstallationhasbeendonealready.Returntothe
Installationsectionandconnecttheunitsina1+1configurationifrequired.
1) Followthestepsfor1+0onthemainlinkasdescribedabovewiththebackup
unitsturnedoff.
2) Turnthestandbyradiounitson,butensuretheopmodeisoffonbothtoavoid
disturbingtheactivelink.
3) OntheActiveLinkConfigPageclicktheFailoverModewithPortOffbutton:

Figure36FailoverModeSet
4) RepeatfortheActivelinkotherendunit.
5) ThedisplayfortheLinkstatusatthetopofthepageshouldchangetoshowboth
ActiveandStandbyunitsGreenforall4units.
6) Thesystemisnowsetupin1+1mode.Ifthemainlinkfails,theportswillbeshut
downonthemainlinkandthetrafficwillflowthroughthestandbylink,allowing
connectedswitchestoreroutethetraffic.
7) ClicktheConfigSavebuttonatthelowerleftofanywebpageThismustbe
doneonbothsidesofthelink.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

85

AdaptiveCodingandModulation(ACM)(Optional)
EnablingACMpermitsconfigurationoftheMSEImproveandDegradethresholds.Itis
recommendedtousethedefaultvaluesforbestperformance.SelecttheOnbutton
andthenclickonthesubmitbuttontomakethechangeifACMisdesired.

Figure37ACMSetup

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

86

AutomaticTransmitPowerControl(ATPC)(Optional)
EnableATPCtomaintainthereceivesignallevelataconstantlevel(targetRSSI)during
rainfading.ATPCistypicallyusedforveryshortrangelinksthatrequiretheinputlevel
intotheradiounittobereducedtoavoidsaturatingthereceiver.EnablingATPCresults
inatransmitpowerlevelonbothsidesofthelinkthatislowerthanthemaximumlevel
forthesetmodulation.Ifsetpowerwouldnormallybethemaximumlevelandthe
receiverwillnotbeoverdriven,itisrecommendedtoleaveATPCoffsinceitwillnever
beexercised.

Alarms,RPSandTelnet/TFTPDaemons
TheSystempagealsoallowstheindividualalarmsonthefrontpaneltobeenabledand
disabledfromthewebthesecanbeusedtoturnvariousotherdevicesonandoffas
longasthecurrentandvoltagelimitsoftherelaysarenotexceeded.Thetelnetandtftp
daemonscanalsobeturnedonandofffromthewebtocontrolaccesstothesystem.
TheRapidPortShutdowncanbeenabledordisabledhereaswelltoallowforrouting
protocolstoreroutetrafficifthelinkshouldgodown.

Figure38ATPCSetup/RPS/Telnetd/tftpd/alarms

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

87

EthernetConfiguration
TheEthernetpageallowstheindividualEthernettrafficportsonthefrontpaneltobe
enabled,disabled,andconfiguredfromthewebThetwomaintrafficportsGE1and
GE2canbeconfiguredfor10/100/100BaseToperation.IftheAutoNegoissetto
disable,theAutosensingfunctionisalsodisabledandthematchingsettingsmustbe
madeontherouterorswitch.OtherwisethelinkbetweenthedeviceandtheIDUvia
theEthernetcableforthespecificEthernetportwillbelost.
ThePrioritysettingallowsassigningpriorityforalluntaggedtrafficonthatportfrom0
to7(7beinghighest).Ifapreviouslytaggedpacketarrives,thepriorityfieldintheVLAN
tagCOSfiledwilltakeprecedenceovertheportpriority.Alluntaggedtrafficwillbe
giventheportpriority.
Ingressratelimitingallowstheoperatortorestrictthetrafficonanyoneporttoa
maximumrate,whichallowssomebandwidthshapingforeachport.
TheSFPports,GE3andGE4arefixedat1000BaseTbutcanaccommodatesingleand
multimodefibermodulesaswellascopper.

Figure39EthernetSetupPage

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

88

StatusMonitoringOverview
TheWebinterfaceprovidesmanywaystolookatthestatusofthetrafficflowingacross
thelinkandthehealthofthelink.ThefollowingFiguresshowthevariouscountersthat
canbemonitored.
SystemStatus
ThispagedisplaystheRadioandSystemStatus.TheSystemcontainsinformationonthe
Alarms,IDUtemperature,andfanstatus.TheRadiostatusdisplaysRSSI,MeanSquare
Error(MSE),BitErrorRate(BER),FrameErrorRate(FER)andODUtemperatures.The
temperaturesarethetemperatureinCelciusinsidetheODUandIDUunitsandwill
alwaysbehigherthantheoutsideairtempby1520degrees.

Figure40SystemStatusPage

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

89

LinkStatus
Containsthestatusonthemodem,EthernetPorts,T1/E1,andEthernetports.
Allthestatusindicatorsshouldbegreenwhenworkingproperly.Redusuallyindicates
thatanODUisoffornotconnected,orpossiblyarealhardwarefailure.AGreystatus
indicatorrepresentsanindicatorthatdoesnotapplyforthemodelofODUbeingused.
TheT1/E1PortStatusindicatorswillonlyturngreenwhentheT1/E1portisconnected
withavalidsignalformat.

Figure41LinkStatusPage

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

90

EthernetStatistics
ContainsstatisticalinformationonindividualfrontpanelEthernetports.Thesestatistics
areusedtodeterminetheerrorrateoftrafficandthetrafficflow.
IN:Meanstrafficbeenreceivedfromthedevice(Switch/Router)attachedtothe
particularGigEport.
OUT:MeanstrafficsentfromtheIDUtothedeviceattachedtotheparticularGigEport

Figure42EthernetStatisticsPage

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

91

RFStatistics
ContainssummarystatisticalinformationontheRFinandRFoutinterfaces.RFout
showsstatisticsforthetotalpacketsplusT1/E1andACMoverheadframestransmitted
tothefarendofthelink.RFinshowsthesameinformationforpacketsreceivedfrom
thefarend.
ThePortrateisupdatedevery20seconds.ThePortUtilizationisapercentageofthe
totalavailablecapacitybeingusedandisalsoupdatedat20secondintervalsfrontpanel
Ethernetports.Thesestatisticsareusedtodeterminetheerrorrateoftrafficandthe
trafficflow.

Figure43RFStatisticsPage

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

92

T1/E1Statistics
ContainsindustrystandardstatisticalinformationoneachT1/E1interface,updated
every20seconds.

Figure44T1/E1StatisticsPage

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

93

DiagnosticOptions
IDULEDallowssettingtheLEDsundertheTDMportstoindicatetheTDMportstatusor
representtheRSSIlevelreadfromtheODU.
LoopbackModeisusedfortroubleshootingandwillenablethetraffictobeloopedback
eitherattheIDUIFsectionjustbeforetheODUconnector,oratthedigitallevelinside
themodem.Thisfeatureisveryusefulforfaultisolationduringsetup.
DiagnosticExportgeneratesadiagnostic.binfile.Todownloadthisfile,theTFTP
functionoftheIDUmustbeenabled.ThenfromthePCscommandprompt,executethe
followingcommand:tftpi[IPaddressoftheIDU]getdiagnostic.binThefilewillhave
tobesubmittedtoTrangoProductSupportforprocessing.
ResetConfigwillrestoreallthesettingontheIDUtofactoryexcepttheIPstackandthe
licensekeys.

Figure45DiagnosticOptions

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

94


SystemLog
Thesystemlogrecordsevents,errors,andstatisticswithtimestampsattached.Thelog
levelcanbeadjustedviatheCLI.Loglevelsare0,1and2.Level0isusetoidentified
anyconfigurationsettingexecutedatbootupbytheIDUaswellasanyerrorsreported
atbootup.
Level1isusetoidentifyanyeventsthataretriggeredatthecommandline,likesaving
theconfigurationorchangingthefrequency.
Level2isusetoidentifiedlinkstatisticsonaperiodicbasis.Itisrecommendedthatthis
levelonlybeusedfordebuggingsincetheentiresyslogmemory(about1500entries)
willbeusedupquicklyandoldereventsmaybeoverwritten.
TheSyslogExportprocessissimilartotheDiagnosticExportprocess(SeeDiagnostic
Exportabove).Thenameofthefiletodownloadissyslog.txt

Figure46SystemLog

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

95

ConfigView
ConfigViewallowscompletedisplayofthesystemconfigurationandalsoexportingthe
configurationfileasarecordofthesystemsetup.ByclickingontheConfigExport
button,thesystemwillgenerateaconfig.txtfile.Followthesameprocedures
mentionedundertheDiagnosticExportsectionabovetodownloadtheconfig.txtfile.

Figure47ConfigView

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

96

UserSettings
AllowssettingthesystemremarkfortheIDUwhichisdisplayedatthetopofeveryweb
page,aswellaschangingtheLoginPasswordfortheweb(HTTP)interface.

Figure48UserSettings&Password

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

97

CommandLineInterface(CLI)BasedConfiguration
CLIBased1+0Configuration
Thissectioncoversallthebasicsthatarenormallyrequiredforsettingupthelinkusing
eitherthetelnet,SSH,orserialCOMporttoaccesstheunits.Stepbystepinstructions
withsessionexamplesaregiven.TheCLIinterfacehasmorefunctionsavailablethanthe
WebInterface.Simplytypethe?toseealistofavailablecommands.
Step1:ConnecttoEachUnitviaoneoftheCLIinterfaces
Inalltheexamplesgiven,telnetwasused,buttheloginprocedureissimilarforeach.To
logintoeachunitsusingthedefaultIPaddressof192.168.100.100.
Usethewindowstelnetprogramoranyothertelnetclientprogram.Whenprompted
fortheLoginenteradminandforpassword,entertrango.TheTrangoSystems
commandlineinterfaceapplicationshouldrespondasfollows:

Microsoft Windows XP [Version 5.1.2600]


(C) Copyright 1985-2001 Microsoft Corp.

C:\Documents and Settings\user>telnet 192.168.100.100

CLI login: admin


Password:

Trango System:

TrangoLINK GigaPlus Command Line Interface v1.3.0

Whenloggingintotheradiounit,theoperatoralwaysentersthe(CLIview)#node,from
whichonlystatusofthesystemcanbeseen.Tomakechangestosystemsettings,the
operatormustenterthe(CLIconfig)#nodeoftoallowchangestothesystemtobe
made.Typethecommandconfigandthepasswordtrango.Thepasswordcanbe
changedlater.

(CLI-view)# config
Password:

Step2:ChangetheOutofBand(OBM)ManagementIPAddress
TrangoSystems,Inc.

GigaPlusUserManualRev1.3

98

ItisrecommendedtochangetheIPaddressonbothendsoftheradiofirst,before
installingthelinktoensurethatnoproblemswillbeencounteredaccessingtheunitsin
thefieldfromthedestinationnetworksubnet
TochangetheIPaddressofthesystem,firstchecktheipsettingsusingtheipcommand.

(CLI-config)# ipconfig
IP Address:

192.168.100.100

Subnet Mask:

255.255.255.0

Gateway IP:

192.168.100.1

ETH1 MAC:

00:01:de:81:65:44

ETH2 MAC:

00:01:de:81:65:45

Next,changetheIPaddressandsubnetmask.Thesystemwillnotberesponsiveafter
thechange.ReconnecttotheGigaPlususingthenewIPaddress.

CLI-config)# ipconfig ip 10.14.1.41 255.255.254.0


IP Address:

10.14.1.41

Netmask:

255.255.254.0

SUCCESS

Afterreconnecting,changethegatewayaddressasnecessary.
(CLI-config)# ipconfig gateway 10.14.0.1
Gateway IP:

10.14.0.1

SUCCESS

Confirmthatthechangesaremade:

(CLI-config)# ip
(CLI-config)# ipconfig
IP Address:

10.14.1.41

Subnet Mask:

255.255.254.0

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

99

Gateway IP:

10.14.0.1

ETH1 MAC:

00:01:de:81:65:44

ETH2 MAC:

00:01:de:81:65:45

Step3:TurntheODUSectionoftheradioon
TypeodupowerontoapplypowertotheRadiosectionoftheunit.AftertheCLIreturns
thestatusofon,entermodeltoshowthemodels,serialnumbers,TRspacingand
transmitfrequencyrangeoftheunit.

(CLI-config)# odupower on
ODU Power enable:

on

SUCCESS

(CLI-config)# model
IDU Model:

IDU-GigaPlus-1

IDU Serial ID:

8480068

ODU Model:

HP2-23-1200-3A

ODU Serial ID:

C110301327

Tx Freq Min:

22000.00

Tx Freq Max:

22400.00

Freq Duplex:

1200.00 (MHz)

Step4:SettheTransmitterandReceiverCenterfrequency
Thecenterfrequencymustbewithintheminandmaxshowninthemodelcommand
andmustbeatleastoftheoccupiedtransmitterbandwidthawayfromthelimitsfor
properoperation.
EnterthetransmitfrequencyinMHz(theresolutionofthefrequencyis.250MHz).The
receivefrequencywillautomaticallybeprogrammedasfollows:
ForAmodels,RXFreq=TXfreq+FreqDuplex.
ForBmodels,RXFreq=TXFreqFreqDuplex.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

100

InsomecasestheFreqduplexcanbechanged,buttypicallythiswillnotbenecessary.
ChangingtheFreqduplexwillautomaticallychangetheRXfrequency.Theopmode
mustbeofftosetthefrequency.
Firstsetthelocalendtransmitfrequency:

(CLI-config)# freq 22300


Tx Freq:

22300.00 (MHz)

Rx Freq:

23500.00 (MHz)

Freq Duplex:

1200.00 (MHz)

Next,Setthefarendtransmitterfrequency(separatesessionwiththeotherradio)
(CLI-config)# freq 23500
Tx Freq:

23500.00 (MHz)

Rx Freq:

22300.00 (MHz)

Freq Duplex:

1200.00 (MHz)

Ifthesystemhasbeeninstalledandthefarendtransmitterisalsoonthelinkcanbe
checkedusingthelinktestcommand

(CLI-config)# linktest
LOCK
1>

RSSI

MSE

-45.00

-36.70

BER
0.00E+00

Step5:EnableAdaptiveCodingandModulation(ACM)(Optional)
IfACMisdesired,theacmenablecommandshouldbeusedonbothendsofthelink.
IMPORTANT:AftertheACMisenabledafterinitiallinkestablishment,thespeed
commandmustbereissued.

(CLI-config)# acm enable on


ACM enable:

on

SUCCESS

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

101

Thetwostepsabovemustbedoneonbothendsofthelink,startingwiththeunitthat
doesnothaveoutputbandmanagementorwhichreliesontheGigaPlusIBM
connectionformanagement
Step6:SettheSpeedandModulation
Thespeedsettingmayrequirealicensekeyiftheresultingpayloadspeedisabove100
Mbps.Thecommandspeedshowsthecurrentmodulation,BandwidthinMHz,Symbol
RateinMsym/sec,andthepayloadspeed(capacity)inMbps.

(CLI-config)# speed
Modulation:

128QAM

Bandwidth:

20.00

Symrate:

17.42

Speed:

111.00

Step7:EnabletheTransmitters
Turnopmodeononbothendsofthelink.Thisenablesthetransmitterontheunit.
Aftertheopmodeisturnedon,theTXfrequencycannotbechangedunlessopmodeis
turnedoffagain.

(CLI-config)# opmode on
Opmode:

on

SUCCESS

Step8:Verifythelinkisworking
Runthelinktestcommandtoconfirmthatthelinkisrunningproperlyafterenabling
ACM.NoticethattheTxandRxmodulationlevelsarenowshown.Now,ifthelink
conditionsdegradeduetorainfading,eithertheTxorRxmaydownshiftduringthefade
event.Runningthelinktestcommandagainwillshowthelowermodulationsuchas
64QAM,32QAM,etc.forTxorRx.TheRSSIwillalsolikelychangeforrainfading,but
mayremainunchangedifthelinkdegradationisduetomultipath.Themodulation/RSSI
willautomaticallyreturntothesetvalueoncethefadingconditionhaspassed.

(CLI-config)# linktest

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

102

LOCK
1>

RSSI

MSE

BER

-38.00

-35.00

0.00E+00

Tx
128QAM

Rx
128QAM

Step9:Savetheconfiguration
Runtheconfigsavecommandtosaveallthesettingsthatwerechangedintonon
volatileFLASHmemory.Ifapowerinterruptionsshouldoccur,thelinkwillreestablish
itselfaftertheinterruptionisover.(assumesdefault_opmodeonwasenabledandthe
configurationsavedpriortothepowerinterruption).

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

103

CLIBased1+1HotStandbyConfiguration
Thissectionassumesthatthephysicalinstallationhasbeendonealready.Returntothe
Installationsectionandconnecttheunitsina1+1configurationifrequired.
Stepstoconfigure1+1HotStandby:
1) Followthe1+0configurationsectiontoestablishalinkbetweenthetwomain
endsofthelink,withthesecondpairofradiosturnedoff.Theantennasshould
bealignedatthispoint.
2) Forbothendsofthemainlink:
a. SetthefailoverfunctiontoONusingthefailovercommand.
b. Setopmodeon.
c. Setdefault_opmodeon.
d. Savetheconfigurationusingconfigsave
e. Powerbothendsofthelinkdown.
3) Bringthesecondlink(Standby)upusingthesameconfigurationasthemainpair.
a. SetthefailoverfunctiontoONusingthefailovercommandonbothends
ofthestandbylink.
b. Savetheconfigurationusingconfigsave
c. Powerbothendsofthelinkdown.
4) ConnecttheredundancycableCBLDATRIU3betweenthetwoIDUs.
5) Powerbothmainlinkup
6) Afterthelinkisestablished,powerupthesecondlink.
7) Aftertheelectionperiodexpires,thetwounitsateachend(activeandstandby)
willsyncupwiththeproperutypeandconfigurationsettings.
8) Verifybyrunningthefailovercommandandobservingthestatus.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

104

AntennaAlignment
AfterBasicSetupofthelink,theantennascanbealigned.
Aligningnarrowbeamwidth(<2deg)overlongdistancescanbeadifficultprocess
withouttheproperequipment,patience,andacarefulprocess.
UsingaGPScompassandthePathAnalysistoestablishacrudeazimuthandelevation,
theinstallationcrewcanmounttheAntennaAssemblyonthesupportingstructuresat
eachendofthelink.Oncetheantennasareinstalledandaroughantennaalignment
hasbeenestablished,thenthefinealignmentprocesscanbeginatoneendofthelink
(typicallythesitewiththesmallerantenna).
OnceonesideisalignedtoachievebestRSSI,MSE,andBERthentheoperatorcan
adjusttheothersidetoimprovethelink.Alignmentcanbedoneusingthelinktest
commandfromthecommandlineinterface,orthevoltageindicationfromtheBNC
connectorontheODU.

Figure49BNCConnectorforRSSIVoltage
RunthelinktestcommandwhilealigningtheantennaandlookfortheMSEtoimprove
(ahighernegativenumber)whileadjusting.Whenthelockstatuschangesto1,you
mayfinetunethealignmentwiththeLEDdisplay
AntennaAlignmentProcedure
1.

Ensurethatbothsidesofthelinkareconfiguredcorrectly.

2.

ConnecttothemanagementportoftheGigaPlus.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

105

3.

Logintotheendofthelinkthatisbeingaligned.

4.

Runlinktest99commandwhileadjustingtheantenna(s),andmonitor
theBNCoutputvoltageuntiltheexpectedvoltage/RSSIlevelisreached.
ThevoltageattheBNCwillrangefrom0.1Voltsat90dBminputlevelto
4.5Voltsat20dBminputlevel.UseavoltmeterandCBLDATRSSIto
monitorthevoltagewhileadjustingtheantenna.Thefollowingequation
canbeusedtodeterminetheRSLwithin3dBaccuracy

RSL(dBm)=15.77xVBNC91.58
BelowisatableshowingthevoltagetoRSLforconvenience.
Voltage
(Volts)
0.1
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
2.5
2.75
3
3.25
3.5
3.75
4
4.25
4.5

RSSI
(dBm)
90
87.6
83.7
79.8
75.8
71.9
67.9
64
60
56.1
52.2
48.2
44.3
40.3
36.4
32.4
28.5
24.6
20.6

Table13RSSItoVoltageConversion
5. OncesatisfiedwiththeRSSIreading,tightendowntheantennainthe
optimumposition.
6. ReplacethesealingcapontheBNCconnectorandtightenuntilitclicksinto
place.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

106

CLICommonTaskReference
SettinguptheInBandManagement(IBM)
TrangopreconfiguresthelinkswithIBMalreadysetupandenabled,howeveritwill
typicallybenecessarytochangetheIBMIPaddressesusedtofittheapplication
managementnetworkandifmanagementacrossthenetworkisdesired,aVLANmust
besetupontheattachedswitches.ThissectioncoversthesetupoftheIBM.
DisplaytheIBMsettings.IntheexamplebelowtheIBMisoff.

(CLI-config)# ibm
IBM Enable:

off

IBM Vlan ID:

4085

IBM Port:

ge1-copper

IBM IP address:

172.16.1.1

IBM Netmask:

255.255.0.0

SUCCESS

EnableIBMusingthesettingspreloaded.

(CLI-config)# ibm enable on


IBM enable:

on

SUCCESS

ChangetheIBMIPaddressandsubnetmask.Eachendofthelinkshouldhavea
differentIPaddress,andinthecaseofmultipledaisychainedlinks,theIPsshouldallbe
different.

(CLI-config)# ibm ip 172.16.1.2 255.255.255.0


IBM IP Address:
IBM netmask:

TrangoSystems,Inc.

172.16.1.2

255.255.255.0

GigaPlusUserManualRev1.3

107

SUCCESS

Verifythesettingsarecorrect.

(CLI-config)# ibm
IBM Enable:

on

IBM Vlan ID:

4085

IBM Port:

ge1-copper

IBM IP address:

172.16.1.2

IBM Netmask:

255.255.255.0

Verifytheconnectiontotheotherendofthelinkbyenteringthedebugnodeandusing
thepingcommandinsidetheApexPlus.Intheexample,theotherendofthelinkhasan
IPaddressof172.16.1.1.

(CLI-config)# debug

Pingtheothersideofthelinkusingthepingcommandfromwithinthedebugnodeof
theradio.

# ping 172.16.1.1
PING 172.16.1.1 (172.16.1.1): 56 data bytes
64 bytes from 172.16.1.1: seq=0 ttl=64 time=6.672 ms
64 bytes from 172.16.1.1: seq=1 ttl=64 time=1.001 ms
64 bytes from 172.16.1.1: seq=2 ttl=64 time=0.979 ms

--- 172.16.1.1 ping statistics --3 packets transmitted, 3 packets received, 0% packet loss
round-trip min/avg/max = 0.979/2.884/6.672 ms

Note:Besidesping,Itshouldbenotedthatfromthedebugpromptatelnetsession
canberuntoconfigurethefarendifdesired.Itshouldbekeptinmindthatany

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

108

changethatwouldbreakthelinkwillresultinlossofcontroltothefarside.Changes
toparameterslikefrequency,speed,oropmodeshouldbedonewithcare.
Returntothecommandlineinterfaceusingtheclicommand.Uponreturningfromthe
debugprompt,thesystemwillbeintheviewnode,sotheusermustlogintotheconfig
nodeifanyfurtherchangesarerequired.

# cli
Trango System:

TrangoLINK GigaPlus Command Line Interface v1.3.0

Returntotheconfignodeusingtheconfigcommand

(CLI-view)# config
Password:

CapacityLicenseActivation
Activatethetrafficcapacitylicenseifneeded.Licensekeysaretypicallyinstalledatthe
factorypriortoshipment.Shouldtheoperatorwishtoreenterthelicensekeys,usethe
licensecommandasshownbelow
(CLI-config)# license 2 <alphanumeric key>
License:

License 2

SUCCESS

AutomaticTransmitPowerControl(ATPC)Configuration(optional)
ConfiguretheAutomaticTransmitPowerControl(ATPC)ifrequired.ATPCistypically
onlyrequiredifthelinkissoshortthatthemaxtransmitpowercannotbeuseddueto
receiveroverload,orforregulatoryreasons.
FirstchecktheATPCstatus.IftheATPCisoffthentheATPCcanbeenabledusingthe
atpcenableoncommand.Intheexamplebelowthemaxpoweriscurrently19dBm

(CLI-config)# atpc
ATPC Enable:

on

ATPC Step Size:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

109

ATPC Max Power:

19.00

Next,settheATPCmaxpowerbasedonthehighestmodulationthatwillbeused.Inthe
examplebelow,thehighesttransmitpowerthatwillbeusedis+17dBm,sotheatpc
max_powerissetaccordingly.

(CLI-config)# atpc max_power 17


ATPC max power:

17.00

SUCCESS
(CLI-config)# atpc
ATPC Enable:

on

ATPC Step Size:

ATPC Max Power:

17.00

Next,setthetargetreceiverlevelthatwillbeusedtocontrolthefarendtransmitter
power.IftheRSSIistoohigh,thentheATPCsoftwarewillsendanATPCpowerdown
commandtotheotherendofthelink.
Thetargetrssimustbesetonbothendsofthelink,justastheATPCmaxpower.The
ATPCsoftwarewillstopsendingcommandstotheotherendofthelinkwhentheRSSIis
within+/2dBofthesettargetrssilevel.

(CLI-config)# targetrssi
Target RSSI:

-45.00

(CLI-config)# targetrssi -40


Target RSSI:

-40.00

SUCCESS

CheckEthernetandRFportStatistics
Runthestatusportcommand

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

110

ThiscommandshowsthecurrentEthernetportstatisticsandtoprovideconfirmation
thattheconnectiontothenetworkequipmentissetupproperly.Thesystemdefaultis
autonegotiate.Thege1andge2portsaremappedtothecopperports,andge3and
ge4aremappedtotheSFPdataports,andthege0portistheinterfacefromthe
internalswitchinsidetheODUtothemodem.
Thege0statisticsaretypicallynotmonitoredandaremadeavailablefor
troubleshootingpurposesonly.TheRFcountersindicatethestatisticsforthereceive
portandthetransmitport.
TheOctet/PacketcountsontheRFcountersmaybeslightlyhigherduetointernal
messagingbetweenthetwoendsofthelinkforinternallinkmanagement,andagain
theyareprimarilyfortroubleshootingpurposesanddonotneedtobemonitored
continuously.
MonitoringtheRFdropcountsisusefulfordeterminingiferrorsareoccurringoverthe
wirelessportionofthelink.
Theportrateandportutilization(percent)arealsousefulformonitoringsincetheycan
indicatealinkrunningatcapacity.Thesetwometricsaccountforthesumofallthe
Ethernetportsbeingused.

(CLI-config)# status port


<====================== Ethernet Counters ======================>
Port:

ge1

ge2

ge3

Enable:

on

on

on

on

Status:

off

off

off

off

Duplex:

full

full

full

full

full

Speed:

1000

1000

1000

1000

1000

362607

4535496

2698731294

4444

2617317006

2323868109

136

922671622

1719593480

3076730927

14415821

2308569723

652052464

Out NUcast Pkt:

135

136

CRC Errors:

20

CollisionError:

In Octets:
In Ucast Pkt:
In NUcast Pkt:
Out Octets:
Out Ucast Pkt:

ge4

nternal
on
on

<======================== RF Counters ==========================>


IN
Total Octets:

TrangoSystems,Inc.

4280834626

OUT
3284730808

GigaPlusUserManualRev1.3

111

Total Pkt:

2328890117

653833881

20

N/A

Port Rate(Mbps):

Port Util(%):

Total Drop Pkt:

Runthestatusclearcommand
AfterthelinkhasbeenestablishedandtheEthernetinterfacesarerunningproperly,the
countersmayallbecleared.Thisistypicallydonejustpriortothelinkvalidationphase
inwhichafixedamountoftrafficorpacketsarepassedoverthelinkoveraperiodof
timetoensurenodropsoccur.Thestatusclearcommandwillclearallportcounters
andtheBERcounters.

(CLI-config)# status clear

Runthesyslogclearcommand
Beforedeploymentitisagoodideatoclearthesyslogsothatonlyeventsafterthelink
wascommissionedarerecorded.Runthesyslogclearcommand.

(CLI-config)# syslog clear

(CLI-config)# syslog
Current 0:19:24:25.990

Viewthemodelinformationusingthemodelcommand
(CLI-view)# model
IDU Model:

IDU-GigaPlus-1

IDU Serial ID:

8480068

ODU Model:

HP2-23-1200-3A

ODU Serial ID:

C110301327

Tx Freq Min:

22000.00

Tx Freq Max:

22400.00

Freq Duplex:

1200.00 (MHz)

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

112

EnableTraps(Optional)
Trapscanbeusedtonotifyexternalnetworkmonitoringdevicesthatathreshold
parameterhasbeencrossed.Thresholdsreavailableforthefollowing:
RSSI
MSE
BER
FER
OMU_TEMP
ODU_TEMP
OUTPORTUTILIZATION(percentageofmaxavailable)
INPORTUTILIZATION(percentageofmaxavailable)

IfthresholdshavebeensetandSNMPTrapassignedasanaction,thecrossingofthe
thresholdwillgenerateatrap.
Thecurrenttrapinformationusingthetrapcommand.ThecurrenttrapmanagerIP
addressesareshownalongwiththeirindividualstatus:
(CLI-config)# trap
IP

Enable

Trap 1:

0.0.0.0

off

Trap 2:

0.0.0.0

off

Trap 3:

0.0.0.0

off

Trap 4:

0.0.0.0

off

Trap 5:

0.0.0.0

off

Setthetrap1managerIPaddressusingthetrapipcommandrepeatforadditional
trapmanageripaddresses:
(CLI-config)# trap ip 1 10.14.1.5
IP
Trap 1:

Enable

10.14.1.5

off

SUCCESS

Enablethetrapnumber1usingthetrapenable1ononcommandThetrapwillbe
enabledandthestatusshown:
CLI-config)# trap enable 1 on
IP
Trap 1:

TrangoSystems,Inc.

Enable

10.14.1.5

on

GigaPlusUserManualRev1.3

113

8.0 Troubleshooting
Thissectionprovidestroubleshootingadviceforproblemsthatmaybeencountered
duringsetupandnormaloperationofthesystem.

Symptom:NoLink(Lock=0duringlinktest)

1) TXFrequencymustEXACTLYmatchtheRXfrequencyontheremoteside.Typefreq
commandfromtheCLItoview.Verifythatthefrequenciesusedmatchthe
regulatorybody(FCCorequivalent)approvedfrequencies.

2) Opmodeisoff.Runopmodecommandtoview,andrunopmodeontoenable.If
theunitwasrebootedandthedefaultopmodeisnoton,theunitwillcomebackon
buttheopmodewillbeoff.Toprevent,rundefault_opmodeoncommandand
configsave.

3) Arethefrequenciesconfiguredcorrectlyoneachradio(TXandRX)?Highfrequency
ontheBsideandlowfrequencyontheAside..

4) IstheODUunitinstalledproperlyontheremotemount(remotemountapplications
only)?Thesystemunitwillonlyoperateinasingleorientationontheremote
mount.Followthedirectionsontheremotemounttoensurecorrectinstallation.
ThearrowsontheRemotemountmustbealignedwiththeVontheODU.

5) ArebothODUsattheendsofthelinkmountedonthesamepolarization?ODUs
mustbemountedwithmatchingpolarizationsateachendofthelink.Ifonesideis
mountedontheantennadifferentlythantheotherside,thelinkwillnotlockorthe
signallevelwillbe2030ormoredBlowerthanexpected.

6) IFACMisbeingused,ACMmaynotbeenabledonbothendsofthelink.Enablethe
ACMandresetthespeedoneachend.Thespeedmustbesetthesameonboth
ends.

MSEistoohighand/orbiterrorsareshowingwhenrunninglinktest

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

114

NOTE:MSE=32dBorloweristypicalfor256QAM,29isaworsenumberandisnot
typical

1) Isthetransmitterpowersettoohighforthecurrentmodulationbeingused.
Consultthelicenseinformationtoverifythatthepowerlevelisnohigherthanthe
maximumallowedforthehighestmodulationthatwillbeused.

2) TargetRSSIsetupmaybeincorrect.ItisbesttosetthetargetRSSIashighas
possiblewithoutoverdrivingthereceiverforthemostrobustoperation.Settingthe
targetRSSItooclosetotheRXsensitivitythresholdwillcompromisethelink
integrity.

3) ArebothGigaPlusODUsmountedonthesamepolarization?ODUsmustbe
mountedwithmatchingpolarizationsateachendofthelink.Ifonesideismounted
ontheantennadifferentlythantheotherside,thelinkwillnotlockorthesignal
levelwillbe30ormoredBlowerthanexpected.

4) IstheODUinstalledproperlyontheremotemount(remotemountapplications
only)?TheODUwillonlyoperateinasingleorientationontheremotemount.
Followthedirectionsontheremotemounttoensurecorrectinstallation.TheArrow
ontheremotemountmustlineupwiththeVontheODU.

5) Presenceofmicrowavetransmittersonsamefrequency(uncommon):Tocheckfor
possibleinterferencefromotherlicensees,turnofftheoppositeendtransmitterand
runtherssicommand.Thesignallevelshouldbe90orlower.Thelevelshouldbe
steadywithinadBorso.

ReceiveSignalLevelistoolow

1) TargetRSSIsetupmaybesetincorrectly(whenusingATPConly).Itisbesttosetthe
targetRSSIashighaspossiblewithoutoverdrivingthereceiverforthemostrobust
operation.SettingthetargetRSSItoolowwillresultinasignallevellowerthan
whatisexpectedifATPCisenabled.

2) ReportedRSSImorethan3dBofftheexpectedRSSI:Theremaybeanalignment
problemwithoneorbothantennas,especiallyifbothsidesofthelinkshowthe

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

115

samesymptom.Amisalignedantennaisoneofthemostcommoninstallation
problems.

Solution:Realigntheantenna(s).Opmodemustbeonattheremotesideofthelink
todoalignmentofthelocalside.EnsurethatATPCisoff.

3) ArebothODUsmountedonthesamepolarization?ODUsmustbemountedwith
matchingpolarizationsateachendofthelink.Ifonesideismountedontheantenna
differentlythantheotherside,thelinkwillnotlockorthesignallevelwillbe30or
moredBlowerthanexpected.

4) IstheODUinstalledproperlyontheremotemount(remotemountapplications
only)?Theradiounitwillonlyoperateinasingleorientationontheremotemount.
Followthedirectionsontheremotemounttoensurecorrectinstallation.TheArrow
ontheRemotemountmustlineupwiththeVontheODU.

RFLinkisgoodbutpacketlossisoccurring:

1) VerifytheduplexandspeedsettingsintheEthernetportarecorrect(100or1Gbit)
andmatchtheconnectedequipment,andthatnoCRCerrorsontheportare
occurring.

2) VerifythattheEthernetportsareconnectedproperly.TheGigaPlusfamilyofRadios
areportmapped,meaningthatthetrafficgoingintoEthernetport1onthelocal
sidewillonlyappearatport1oftheremoteside,localsideport2trafficwillappear
ontheremotesideport2,etc..

3) ChecktheEthernetcablesforcorrectwiring.If1000BaseTisbeingimplemented,
Cat5eorCat6cableshouldbeused.Ensurethatthecableisshieldedandproper
groundingisappliedtotheRJ45connector.

NodirectmanagementusingOutofbandport
IfyoucannottelnetintotheIDUoropenanHTTPbrowsersession,
1) CheckyourEthernetandpowercableconnections
2) Ensurepropercableisbeingusedcrossovervs.straightthroughcable.TheLEDson
theEthernetportshouldbeilluminated.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

116

3) CheckPCssubnettomakesureitisroutabletotheradiosIPaddress.
4) Ensuresnmpdisenabled
5) Ifafirmwareupgradewasjustperformedandonefiledidnotloadproperlyandthe
systemrebooted,youwilllosemanagement.PleasecallTechnicalSupportfor
furtherassistance.

NoRadioManagementconnectionoverthelink

1) VerifytheInBandmanagementissetupproperlyChecktoseeiftheIP
configurationiscorrect,theVLANIDissetandmatchesonbothends,andthatIBM
isenabled.

T1/E1Portsnotpassingtraffic
1) MismatchedT1ports,sincetheT1portsareportmappedT1port1onIDUonemust
beconnectedtoT1port1onthesecondIDU.
2) Ensuretheportisenabledusingthedatapathcommand.Thedatapathmustbeset
toEth+T1orEth+E1,theconfigsaved,andthesystemrebootedatbothsides.
3) VerifypinoutsoftheT1/E1RJ45connector
4) GigaPlusKeyPDHLicenseKeynotactivated

IftherearestillproblemspleasecontactTechnicalSupportat8583910010orEmailat
techsupport@trangosys.com
Beforecallingpleasemakesureyouhavethefollowinginformation.

SerialNumber

Descriptionoftheproblem

Stepstakensofartoresolvetheproblem

Commissioninglog

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

117

AppendixACommandLineInterfaceReference
ThisAppendixprovidesastandaloneguidetothecommandsavailablethroughthe
Telnet,SSH,andconsoleportoftheGigaPlus.

CommandKeyingOverview
KeyFunctions
TabAutocomplete

Completesapartialcommandnameentry.Whenyouenterauniquesetofcharacters
andpresstheTabkey,thesystemcompletesthecommandname.Ifyouenterasetof
charactersthatcouldindicatemorethanonecommand,thesystembeepstoindicate
anerror.Enteraquestionmark(?)immediatelyfollowingthepartialcommand(no
space).Thesystemprovidesalistofcommandsthatbeginwiththatstring.
DelorBackspace

Erasesthecharactertotheleftofthecursor.
Return

Atthecommandline,pressingtheReturnkeyperformsthefunctionofprocessinga
command.AttheMorepromptonaterminalscreen,pressingtheReturnkeyscrolls
downaline.
SpaceBar

Allowsyoutoseemoreoutputontheterminalscreen.Pressthespacebarwhenyou
seetheMorepromptonthescreentodisplaythenextscreen.
LeftArrow
Movesthecursoronecharactertotheleft.
RightArrow
Movesthecursoronecharactertotheright.
UpArrow

Recallscommandsinthehistorybuffer,beginningwiththemostrecentcommand.
Repeatthekeysequencetorecallsuccessivelyoldercommands.
DownArrow

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

118

Returntomorerecentcommandsinthehistorybufferafterrecallingcommandswith
theUpArroworCtrlP.Repeatthekeysequencetorecallsuccessivelymorerecent
commands.

DifferentNodeLevels
ViewNode
This is the default node the users log in. This is strictly for viewing configuration
and statistics only. No configuration changes can be made at this level.
View Node Command List

acm

Display ACM feature status

alarm

Display Alarm status

alignment_sp

Display alignment mode status (SP ODUs only)

atpc

Display ATPC status

ber

Display ber test parameters

cableloss

Display Cable loss values (SP ODUs only)

config

Enable Trango configuration mode

cos

Display current status for class of service

datapath

Display datapath from FPGA

datapattern

Display data source for data pattern

date

Display Time of Day

default_opmode

Display default opmode status

eth_info

Display ethernet port status and configuration

exit

Exit current node

failover

Display failover (1+1 HSB) mode

fanctrl

Display Fan status

freq

Display Rf Tx/Rx frequency

guard_time

Display failover guard time

help

Display help command

httpd

Display Web server (httpd) status

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

119

Ibm

Display In Band Management configuration

iduled

Display the iduled function (TDM or RSSI)

ipconfig

Display radio management port configuration

license

Display license enable status

link_history

Display how many times link dropped since power on

linktest

Display link test values (RSSI, MSE, BER)

loglevel

Display the current loglevel for the syslog

loopback

Display loopback Mode

model

Display IDU/ODU Model and serial number

mse

Display the MSE (Mean Square Errors) value

oduled

Display ODU rssiled status

odupower

Display ODU Power status

odurxagc

Display ODU Rx AGC status

opmode

Display Operation Mode status

power

Display Tx power in dBm

remark

Display product remarks

rps

Display current status of rapid port shutdown

rssi

Display RSSI value

show

Show running system information

siglevel

Display signal path debugging parameters

snmpd

Display SNMP Agent Daemon (snmpd) status

speed

Display current modulation and symbol rate(speed)

status

Display status for different device and ports

Sync_status

Current 1+1 HSB peer sync status (Failover active)

sysinfo

Display MSE, FER information

syslog

Display system event log

targetrssi

Display target rssi value

tdm

Display TDM configuration

telnetd

Display telnetd server (telnetd) status

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

120

temp

Display IDU and ODU temperature

tftpd

Display tftp server (tftpd) status

threshold

Display threshold status

trap

Display SNMP Trap IP configuration

uptime

Display system uptime

Utype

Display the current unit type (Active or Standby)

version

Display IDU/ODU Software version

voltage

Read voltage values from PIC

ConfigNode
Userscanenterthisnodebytypinginthecommandconfigfromtheviewnode.They
willbepromptedforapasswordandaftersuccessfulauthenticationusersentersthe
configmode.Allconfigurationsettingscanbechangedhere.

Allthecommandsenteredwithoutanyparametersreturnsthecurrent
configuredvaluesandaresimilartoviewnode.

Allconfigurationchangesareappliedimmediatelyanddontrequireanyreboot
(exceptspeedinwhichthesettingsareappliedimmediately,butitdoes
requirerebootaftersave).

Allconfigurationchangeshavetobesavedinordertobepersistentacross
reboot.Asinglesavecommandwillsaveallconfigurationchanges

Userscangobacktotheviewnodebytypinginthecommandexit

Config Node Command List

CLI

Ranges

Default Value

acm

on/off

Off

alarm

on/off

Off

alignment_mode

on/off

Off

atpc

on/off

Off

ber

0E00 to 2E-03

N/A

bootimage

<upgrade | toggle> <0-5>

N/A

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

121

cableloss

<0-20> <0-30> <0-50>

0,0,0

config

export, import,remove,view

N/A

cos
Priority 0:
Priority 1:
Priority 2:
Priority 3:
Priority 4:
Priority 5:
Priority 6:
Priority 7:

COS Queue = 0
COS Queue = 1
COS Queue = 2
COS Queue = 3
COS Queue = 4
COS Queue = 5
COS Queue = 6
COS Queue = 7

datapath

<0-2>

datapattern

<fpga | modem>

fpga

date

<0-99><1-12><1-31><0-23><0-60>

Linux System Date

debug

N/A

N/A

default_opmode

<on/off>

Off

diagnostic

N/A

N/A

eth_info

<1-6>

N/A

exit

N/A

N/A

failover

On/off

off

fanctrl

<0-2>

freq

depends on ODU model

0 (this is exception to the valid range)

freq_duplex

ODU dependent

N/A

ftp

N/A

N/A

get

N/A

N/A

guard_time

10-30 seconds

15 seconds

help / ?

N/A

N/A

httpd

<on/off>

On

ibm

<on/off> <ip address> <Vlan>

off

iduled

TDM/RSSI

RSSI

ipconfig

<ip address><netmask><gateway>

ip

192.168.100.100

netmask:

255.255.255.0

gateway:

192.168.100.100

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

122

Reset will not reset ipconfig, use reset


ipconfig to reset the ip address settings.
license

N/A

None
N/A

license_speed

<1-2> Key

N/A

license_tdm

Key

N/A

N/A

N/A

linktest

duration <1-99>

Default 1 (if duration not entered by


user)

loglevel

<0: Setting, 1: Event, 2: Status>

0,1

loopback

<dig | if | rf_gen | rf_refl | off>

Off

model

N/A

No defaults, read directly from the


IDU/ODU

mse

duration <1-99>

Default 1 (if duration not entered by


user)

oduled

<on/off>

On

odupower

<on/off>

Off

odurxagc

<on/off>

Off

opmode

<on/off>

Off

passwd

<passwd> <confirm_passwd> (8char)

trango

link_history

<eth > <1-4> <auto_nego, duplex,


enable, maxrate, pause, priority,
speed

All 4 ports configured in the Auto-Neg


Mode

power

0-30

10dBm

prompt

Character string

N/A

reboot

N/A

N/A

port

TrangoLink GigaPLUS
remark

<string 1-100bytes>

Reset will not change the remark settings

reset

N/A

N/A

rps

on/off

off

rssi

Duration <1-99>

Default 1 (if duration not entered by

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

123

user)
CLI View Node:

trango

CLI Config Node:

trango

SNMP read comm:

public

SNMP write comm:

private

Web Interface:

trango
trapstr

show

<passwords>

snmp trap:

siglevel

N/A

N/A

snmpd

<on | off >

On

speed

<channel_bw> <modulation>

<0> <qam16>

channel_bw

4/7/10/14/20/28/30/40/50/55/56/80

modulation

qpsk, qam16, qam64,qam128,qam256

qam16

<modem | fifo | pll | port | all |


clear>

N/A

sync

N/A

N/A

sync_status

N/A

N/A

sysinfo

<0-6>

0 (if command executed without any


param)

syslog

<clear>

N/A

targetrssi

<-88 - -25)

tdm

<coding. <mode>

AMI T1

telnetd

on/off

on

temp

N/A

N/A

tftpd

on/off

Off

status

-40

<param> <min | max> <value>


<action>
param : 0 rssi, 1 mse, 2 ber, 3 fer, 4
idu_temp, 5 odu_temp
min|max: param dependent
threshold

action: 0 none, 1 alaram1, 2 alarm2 ,3


snmptrap

Default action is None.

trap

<enable, ip, cr>

0.0.0.0

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

124

Reset will change the prev configured


trapip
enable

<0 5>

N/A

ip

<1 -5 > <A.B.C.D>

N/A

cr

N/A

N/A

uptime

N/A

N/A

utype

N/A

Main

utype_switch

N/A

N/A

version

N/A

N/A

voltage

N/A

N/A

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

125

DebugNode
Thisnodeisadditionalmanagementportrelatedsettingsandusersenterthedebug
node,bytypinginthedebugcommandfromtheconfignode.Userscanreenterthe
viewnodebyenteringtheclicommandfromwithinthedebugnode.

DebugNodeCommandList

cli

N/A

UsedtoEntertheCLI(trangoview)node

help

N/A

Displaylistofcommandsinthedebugnode

ping

<ipaddress>

pingnetworkhosts

route

N/A

Displaythecurrentsystemroutingtable

ssh

<ipaddress>

sshintoanotherhost

syslog

N/A

printsystemlog

telnet

<ipaddress>

telnetintoanotherhost

tg_reboot

N/A

Rebootradio

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

126

IndividualCommandDetails

acm

SYNTAX

acm
acmenable<on|off>
acmmod<modulation>mse_im<400>
acmmod<modulation>mse_de<400>

profile
QPSK
16QAM
32QAM
64QAM
128QAM
256QAM

mse_im
20.3
25.3
26.3
29.2
32.1
NA

mse_de
NA
18.5
21.3
24.3
27.2
27.2

enable
enabled
enabled
enabled
enabled
enabled
enabled

ConfigurationStorage:Yes
acmwithoutanyparameterwilldisplaythecurrentstatusofACM
thresholdvalueandenableoptions.

DESCRIPTION

acmisusedtodisplayACMfeaturesparametersincludingACMenable,and
MSEvaluesintheimprove/degradethresholdtables.
acmenableisusedtoturnontheadaptivecodingandmodulationfeature.
Whenenabled,thecurrentRXmodulationmayshifttodifferentprofile
basedonthecurrentMSEvalueandasetofpredefinedMSEdegradeand
improvethresholds.Thespeedcommandneedstobeissuedafteracm
enableon/offcommand.

ACMisnotsymmetricandeachend(TxRx)mayhavedifferentprofilesata
giventimedependingupontheMSEvaluesoneachend.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

127

acmmodeisusedtoupdateMSEvaluefordegradeorimprovethreshold
table.Thenewthresholdvaluesshouldbeeffectimmediatelyupon
execution.

Certainprofilesarenotavailablewheninitialspeedmodulationisat
QAM256.Belowistheavailableprofiles:

profile
QPSK
16QAM
64QAM
256QAM

mse_im
20.3
25.3
29.2
32.1

mse_de
17.10
18.5
24.3
27.2

enable
enabled
enabled
enabled
enabled

Note:Enable/disablecertainprofilefunctionalityisnotsupportedinthis
release.

alarm

SYNTAX

alarm
alarm<alarm1|alarm2><on/off>

Default:alarm1OFF,alarm2OFF
ConfigurationStorage:No
alarmwithoutanyparameterwilldisplaythecurrentstatusforbothalarm1
andalarm2
alarmisasystemlevelcommand.

DESCRIPTION

Usermayspecifyalarm1oralarm2astheactioninthethresholdsettings.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

128

Thiscommandisusedtoturnoffthealarmafterthealarmhasbeen
triggered,orturnonanalarmremotely.
Alarmsarealsosetbythesysteminternallywhencertainconfigured
thresholdsareexceedingitsexpectedrange.

atpc

SYNTAX

atpc
atpcenable<on|off>
atpcmax_power<030>
atpcstep_size<05>

Default:enableOFF,maxpower17dBm,stepsize1
ConfigurationStorage:Yes
atpcwithoutanyparameterwilldisplaythecurrentstatusofATPCfeature

DESCRIPTION

atpcisusedtodisplayATPCfeaturesparametersincludingATPCstepsize,
ATPCenable,andATPCmaxpower.

atpcenable:ATPCisusedtoautomaticallyadjusttheremoteendODU
transmitpowerinordertomaintainthedesiredlevelofRSSI(within2dB
rangeoftargetrssi)atthelocalend.Thisfeaturewillworkonlywhenboth
localandremoteradioareenabled.
atpcmax_power:SetthemaximumATPCpower.Thisparameterisused
onlywhentheATPCisenabled.
UsercannotexecutethepowercommandwhenATPCisturnedon.The
systemwilladjustthepowerautomaticallybasedonthemax_powerand
step_size.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

129

atpcstep_size:SpecifiedthestepsizeforeachoftheATPCcommandfor
powerup/down
Bydefault,foreachoftheatpcpowerup/downcommandfromthe
remoteunit,therewillbe1dBincrement/decrement.Theusermay
specifythisstepsizetomaximumof5dBpercommand.Thepower
commandtoODUis1dBatatime,butwillgouptonumberofstepsize
perATPCcommand.
Theuserisresponsibleformeetinglegal/regulatoryrequirementsforTx
power.

EXAMPLE

(CLIview)atpc

ber

SYNTAX

ber
ber<099durationinseconds>

Default:1second
ConfigurationStorage:Yes
berwithoutanyparameterwilldisplaythecurrentBER,LOCK,MSE,RSSI
values

DESCRIPTION

BERappliestoEthernetDataonly,andisbasedonCRC.FCserrors,and
onlyisfunctionalwhenthedatapatternissettointernalmode.Itwill
alwaysbezeroonlivetraffic.

bootimage

SYNTAX

TrangoSystems,Inc.

bootimagetoggle

GigaPlusUserManualRev1.3

130

bootimageupgrade<idu|odu>

Default:N/A
ConfigurationStorage:NO
bootimageisasystemlevelcommand.

DESCRIPTION

bootimagetoggle:Toswitchcurrentimagesbacktothepreviousupdated
imageinasetofFPGA1,FPGA2,OS,FW.PICandODUfirmwarearenot
allowedtobetogglebackunlessperformingbootimageupgradeagain.
bootimageupgrade:upgradetherequiredsoftwareimagesontheradio,
aftertheimageistransferredontheradioviatftp.
<idu>optionwillupgradealltheIDUfirmwareinsequenceofFPGA,OS,
FW,PICfromONEtarfileunder/tmp/idu_GigaPlus_vX.X.tarrebootis
requiredaftertheiduupgrades.
<odu>optionwillupgradeODUfirmwarewiththefileunder
/tmp/odu_fw.binor/tmp/rem_fw.bin(nameisnotexchangeable)

cableloss

SYNTAX

cableloss
cableloss<loss140><loss315><loss915>

Default:0forallthreechannels
ConfigurationStorage:Yes

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

131

cablelosswithoutanyparameterwilldisplaythecurrentcablelossvalues
fortheIFcablegoingtotheODU
Validrangeofoperation:
loss140:range015,loss315:range026,loss915:range050

DESCRIPTION

ThiscommandisonlyapplicableforSPODUs
cablelosscommandisusedtosettheappropriatecablelossforthe3
frequenciesbasedonthelengthoftheIFcoaxialcableusedtoconnectthe
IDUandODU.
cablelossinfomustbesenttotheODUsothatitcanmaintaintheoutput
Tx/Rxpowerlevelsaccurately.ThisonlyappliestoSPODUs.Forsystems
withHPODUsnocablelosssettingisrequired.Thecableloss
compensationisbuiltinintotheHPODU.

config

SYNTAX

configexport

configimport
configremove
configsave
configview

Default:N/A
ConfigurationStorage:No
configisasystemlevelcommand.

DESCRIPTION

TrangoSystems,Inc.

configexport::TheoptionallowstheusertocreateaASCIIfile(config.txt)

GigaPlusUserManualRev1.3

132

ofthecurrentsystemconfiguration,whichcanthenbetftpfromthePC,
whichtheusercanedit/printorimporttoothersystem

configimport:Thisoptionallowstheusertopushaconfigurationfile
(shouldbeintheformatascreatedbyexport)intothesystemthroughtftp
andthenissuetheconfigimportcommandtoapplythesettingsfrom
theconfig.txtfiletothesystem.

configremove:Thisoptionallowsremovingthecurrentsystem
configurationfileconfig.binandallsettingswillberesettofactory
defaults.Thisisdifferentthantheresetconfigwhereallthepassword
settingsarealsobeingreset.

configsave:Savecommandisusedtosavethecurrentsystem
configurationtotheflash,sothatsystemsettingsarepersistentacross
reboot/powercycles.

Savecommandshouldbeusedaftersystemsettingchange.Otherwiseit
willbelostafterreboot.Multiplechangescanbesavedbyonesave
command.

configview:TheoptiondisplaysthecurrentsystemconfigurationinASCII
formatontheconsole.Thesavedconfigisdisplayed.

cos

SYNTAX

cos
cos<priority><queue>

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

133

Default:
Priority0
Priority1
Priority2
Priority3
Priority4
Priority5
Priority6
Priority7

COSQueue=0
COSQueue=1
COSQueue=2
COSQueue=3
COSQueue=4
COSQueue=5
COSQueue=6
COSQueue=7

ConfigurationStorage:YES
cosisasystemlevelcommand.

DESCRIPTION

Thiscommandisusedtomapthepriorityoftheincomingpackettooneof
the8COSqueuesbasedonthepacketpriorityper802.1p.Thetrafficclass
oftheincomingpacketismapped1to1tothe8priorities.
Theschedulingisstrictprioritywith
COSQ7>COSQ6>COSQ5>COSQ4>COSQ3>COSQ2>COSQ1>COSQ0

EXAMPLE:
(CLIconfig)#cos23
COSmappriority=2,queue=3

SUCCESS

(CLIconfig)#cos
COSscheduling:strict
Priority0:COSQueue=0
Priority1:COSQueue=1

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

134

Priority2:COSQueue=3
Priority3:COSQueue=3
Priority4:COSQueue=4
Priority5:COSQueue=5
Priority6:COSQueue=6
Priority7:COSQueue=7

datapath

SYNTAX

datapath<02>
0:ETHonly
1:ETH+T1
2:ETH+E1

DEFAULTVALUE

0:EthOnly

DESCRIPTION

Selecttheprofiletobeusedonthedatapathoftheradio.
ALicensekeyisrequiredforTDM(T1/E1)mode.
Bandwidthfor8T1or8E1circuitsalwaysreservedonceselected,
regardlessofwhetherdataisbeingsentornot.Thiswillreducethe
Ethernetcapacityaccordingly

RefertoAppendixAforvalidprofilesapplicabletospecificdatapath
mode

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

135


RELATED

Speed,license

datapattern

SYNTAX

datapattern<external|internal>

Default:externaldatapattern
ConfigurationStorage:Yes
datapatternwithoutanyparameterwilldisplaythecurrentstatus

DESCRIPTION

Setsdatasourceforthemodem.datapatterncanbegeneratedfromeither
fpga(external)orthemodem(internal),usedtogeneratePRBSdata

Thedatapatternshouldbesettofgpaduringnormalmodeofoperation,
otherwisenouserdatafromGigEortheT1portswillbetransmitted.

date

SYNTAX

date<year><month><day><hour><minute>

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

136

Default:N/A
ConfigurationStorage:No
datewithoutanyparameterwilldisplaythecurrenttimeofdate.
dateisasystemlevelcommand.

DESCRIPTION

Allowtheusertosetandreadthecurrenttimeanddate

debug

SYNTAX

debug

Default:N/A
ConfigurationStorage:No

debugisasystemlevelcommand.

DESCRIPTION

Exitcurrentnodeandenterthedebugmode.

EXAMPLE

Toenterdebugmode

(trangoconfig)#debug
debug>

RELATED
TrangoSystems,Inc.

cli
GigaPlusUserManualRev1.3

137

defaultopmode

SYNTAX

default_opmode
defaultopmode[on|off]

Default:defaultoperationmodeOFF
ConfigurationStorage:Yes
default_opmodewithoutanyparameterwilldisplaythedefault
operationalmode

DESCRIPTION

Setthedefaultopmodetouserspecifiedinput.
IfON,thesystemtopoweronwithreadytobeoperational
ifOFF,theuserhastoexplicitlyturnonopmode.

Opmodesettingsaredependentupondefault_opmodeafterpowerup

diagnostics

SYNTAX

diagnostic

Default:N/A

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

138

ConfigurationStorage:No
diagnosticisasystemlevelcommand.

DESCRIPTION

Diagnosticcommandistocommunicatewithallsystemdevicesandgeta
currentsnapshotofthesystemstatus.Thisismainlyusedfordebugging
purposes.

eth_info

SYNTAX

eth_info
eth_info<14><14><14><14>

Default:N/A
ConfigurationStorage:No
eth_infowithoutanyparameterwilldisplayconfigurationforall4ports.
eth_infoisasystemlevelcommand.

DESCRIPTION

DisplayEthernetportconfigurationsinclude:enable,status,pauseframe,
autonegotiation,duplex,priority,speedandmaxrate.

Userhavetheoptionstodisplayoneormoreportconfigurationforupto4
portsfordisplay

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

139

exit

SYNTAX

exit

Default:N/A
ConfigurationStorage:No

exitisasystemlevelcommand.

DESCRIPTION

Exitcommandisusedtologoutfromthecurrentnodetothelower
node.Typingexitfromthedebug>nodewillbringusertothelogin
prompt.

EXAMPLE

ToSwitchtoviewnodefromtrangoconfignode
(trangoconfig)#exit
(trangoview)

Tologoutfromthesystem
debug>exit

RELATED

cli,config

failover
SYNTAX

TrangoSystems,Inc.

failover

GigaPlusUserManualRev1.3

140

failover<0:off,1:OnwithportOFF,2:OnwithportON>

Default:OFF
ConfigurationStorage:Yes

failoverwithoutanyparameterwilldisplaythecurrentstatusfor
thefailovermode

DESCRIPTION

Displayandconfigurethefailovermodefeature.Failovercableis
requiredbetweentwoIDUforthisfeaturetoworkproperly.
OptionOFF:Disablefailovermodefeature.
OptionONwithportOFF:StandbyunitdisableallEthernet/TDM
ports.
OptionONwithportON:StandbyunitwillleavetheEthernet/
TDMportenabled.
Whenenabled,aKeepAlivemessagewillbeexchangedbetween
thetwoGigaPlusIDUtodeterminetheirutype.
NOTE:Thiscommandwillsettheutypestatetodefaultand
performelectionperiodwhichwillaffecttheradiolink.Therefore,
itisnotrecommendedtobeexecutedwhilethelinkisrunningwith
traffic.

EXAMPLE

(CLIconfig)#failover
Failovermode:off
(CLIconfig)#failoveron
Failovermode:on
SUCCESS

RELATED

cli,config

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

141

fanctrl

SYNTAX

fanctrl
fanctrl<on|off>

Default:fanON
ConfigurationStorage:Yes
fanctrlwithoutanyparameterwilldisplaythecurrentstatusforthefan.
fanctrlisasystemlevelcommand.

DESCRIPTION

Displayofthestatusofthecoolingfaninthechassisandallowittobe
turnedonandoff.Itisnotrecommendedtoturnthefanoffiftheambient
temperaturesurroundingtheIDUwillexceed10degC.

freq

SYNTAX

freq[tx_freqinMHz]

Default:nodefaultfrequency.0
ConfigurationStorage:Yes

Thesettingoffrequencycanbetothe250kHzresolution.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

142


EXAMPLE:freq17727.5

freqwithoutanyparameterwilldisplaythecurrentTxandRxfrequencyfor
theODU.

DESCRIPTION

Setsthetransmitfrequencyandthereforethereceivefrequency.Only
certainTxRxfrequencypairsarevalidforeachmodeloftheradio.

CertainIDU/ODUPLLsynthesizersareprogrammedforeachandevery
individualfrequency.

GigaPlussupportsmodel6,6E,11,11E,15,18,18E,23,23EofSPODUs
And638GhzHPODUs

freq_duplex

SYNTAX

freq_duplex[duplex]
Default:0
ConfigurationStorage:Yes
freq_duplexwithoutanyparameterwilldisplaythecurrentduplexvalue
ONLYforHPODUs

DESCRIPTION

Setstheduplexvaluetobeusedforprogrammingthetransmitfrequency
andthereforethereceivefrequency.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

143

ftp

SYNTAX

ftp
ftp<server_ip><user_name>
ftp>get<file_name>:performftpgetcommand.Getfilefromtheftp
server
ftp>mode:configureftpoperationmode.Passiveoractive.
ftp>put<file_name><serverpath>:performftpputcommand.Putfileto
theftpserver
ftp>logout:logoutofftpsession.
Default:server_ip=NULL,user_name=NULL,mode=Passive
ConfigurationStorage:No

DESCRIPTION

Toperformftpoperation.ProvidethecommandwiththeftpserverIPand
theuserlogin.Enterthepasswordwhenprompted.

ftp>get<file_name>:DoNOTsupplythepathtothefilethatneedstobe
putontothe.Itwillbestoredinthedefaultsystemdirectory
Seeexamplebelow.

ftp>put<sourcefile><destination>:sourcewillbethefilenameonly,.
Destinationwillincludebothpathandfilename.
Note:fileontheftpservermightneedtobedeletedbeforeitcanbedown
withthesamefilename.

ftp>mode<mode>:DefaultoperationmodeisPassiveandcanbe
configureasactivewiththemodeoption.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

144

ftp>logout:logoutoftheftpsession.

Note:PleaseensurethattheFTPserverisreachablebycheckingwithping
commandfromdebugprompt.
.

EXAMPLE

(CLIeng)#ftp10.14.0.85trango
Password:
ftp>getzImage
#######################################################

Getoperationsuccessfulwithpassivemode

ftp>putlinkloss.txtlinkloss.txt
#######################################################

Putoperationsuccessfulwithpassivemode

ftp>logout
(CLIconfig)#

help/?

SYNTAX

Default:N/A
ConfigurationStorage:No

?isasystemlevelcommand.

DESCRIPTION
TrangoSystems,Inc.

Typingthe?commandwilldisplaythelistofcommandsinthecurrent
GigaPlusUserManualRev1.3

145

nodewithaonelinedescriptionofthecommands

EXAMPLE

(trangoconfig)#?

<DisplaytheListofcmds>

RELATED

N/A

guard_time

SYNTAX

guard_time
guard_time<1030>seconds

Default:15seconds.
ConfigurationStorage:Yes

guard_timewithoutanyparameterwilldisplaythecurrentguardtime
valueinseconds.

DESCRIPTION

Guardtimeisonlyvalidwithfailoverfeatureenabled.Whenevera
switchoverhasoccurred,theguardtimewillbestartedandwithinthe
guardtimeperiod,noadditionalswitchoverisallowed.

httpd

SYNTAX

TrangoSystems,Inc.

httpd

GigaPlusUserManualRev1.3

146

httpd<on|off>

Default:httpdON.
ConfigurationStorage:Yes
httpdwithoutanyparameterwilldisplaythecurrentstatusfortheweb
interfacedaemon
httpdisasystemlevelcommand.

DESCRIPTION

Turnonhttpdserverforwebinterfaceaccess.

Thewebinterfacesupportsbothsecure(https)andnormal(http)access.

ibm

SYNTAX

ibm
ibmenable<on|off>
ibmip<ip_addr><netmask>
ibmport<14:ge1ge4>
ibmvlanid<14088>

Default:enable=OFF,ip=172.16.10.0,netmask=255.255.0.0,vlanid=100.
ConfigurationStorage:Yes

IbmwithoutanyparameterwilldisplaythecurrentIBMfeatures

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

147

parameters.

DESCRIPTION

IbmisusedtoconfiguretheInBandManagement(IBM)channelto
managethesystem.

BothIBMandtheOutofBandManagement(OBM)canbeusedtogether.
ThemanagementVLANIDcanbeconfiguredbasedontheuser
requirementfrom14090.TheIPaddressfortheIBMchannelis
independentoftheOBMportontheIDU.The2IPaddressesneedtobe
unique.

ipconfig

SYNTAX

ipconfig
ipconfigip[ip_addr][netmask]
ipconfiggateway[default_gateway_ip]

Default:IP=192.168.100.100,NETMASK=255.255.255.0,
GATEWAY=192.168.100.100,REMOTE_IP=0.0.0.0
ConfigurationStorage:Yes
ipconfigwithoutanyparameterwilldisplaythecurrentIPconfiguration
andremoteIPaddress.
ipconfigisasystemlevelcommand.

DESCRIPTION

ThiscommandisusedtosetIPaddress,subnetmaskanddefaultgateway
forthemanagementportofthesystem.ThesystemMACaddresscanbe
displayedviathiscommand.Thechangetakesplaceeffectimmediately.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

148

Ipconfigip:BothIPandnetmaskparametersmustbepresent.

Ipconfiggateway:ConfigurethedefaultgatewayIP.ValidforbothInband
andOutofbandport.

license

SYNTAX

licenseDisplaylicenseenablestatus
license_speed<12><speedkey>
license_tdm<tdm_key>

Default:N/A
ConfigurationStorage:No

DESCRIPTION

Licensekeycommandisusedtosetthelicenserequiredforusinghigher
speed(>100Mbps)ontheradio.Speedkey1enablesspeedupto
200Mbpsandspeedkey2enablesMaxspeed.Pleaserefertotheactual
speed/modulation/channelwidthcombinationforvalidprofiles.

Thelicensekeyisspecifictoeachunit(managementportEthernetMAC
address)andisnottransferable.ThePDHkeyenablesallT1/E1portson
theIDU.

Pleaserefertovalidspeedprofiles.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

149

link_history

SYNTAX

link_history

Default:N/A
ConfigurationStorage:No

DESCRIPTION

Thiscommandistodisplayifthelinkhistoryandthelinksteadyflag.

Linkhistory:containsthenumberoflinkup/downoccurredsincethe
systembootupandthisnumberdoesnotgetresetuntiltheradioreboots.

Linksteady:currentstatusoflinksteadyflag.Definedtobe
approximately40secondsafterthelinkhasbeenestablished.

linktest

SYNTAX

linktest<iterations>
Iterationrangefrom199seconds

Default:defaultiteration=1second
ConfigurationStorage:NO

msewithoutanyparameterwilldisplaythecurrentmsevalueforboth
Modem1andModem2

DESCRIPTION

TrangoSystems,Inc.

Linktestcommandisusedtotestthecurrentlinkstatusandcanbeused
tomonitorthelink,basedonthespecifiedduration.CLIpromptwillnotbe

GigaPlusUserManualRev1.3

150

accessiblewhilelinktestisrunning

Thelinktestshowsthefollowingintheoutput

Lock:RadioLockStatus
1:ifallmodemlocksarelocked
0:ifanylockindicatorshowsunlocked
RSSI:ThecurrentRSSIvalue
MSE:ThecurrentMSEvalue
BER:TheinstantaneousBERvalue(1secinterval)

loglevel

SYNTAX

loglevel[02]
<0:Setting,1:Event,2:Status>Default:2
ConfigurationStorage:Yes

DESCRIPTION

loglevelisusedtosettheappropriateloggingforthesystem.
Thiscommandisusedtosetrequiredloglevelsforsystemlogging.Thelog
levelneedstobesetforeachactivitytobemonitored.Oncetheloglevels
areset,thelogscanbemonitoredthroughthesyslogcommand

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

151

loopback

SYNTAX

loopback
loopback<off|if|dig|rfl_gen|rf_refl|baseband>

Default:OFF
ConfigurationStorage:Yes

loopbackwithoutanyparameterwilldisplaythecurrentstatus

DESCRIPTION

Activatesoneoftheloopbackmodesfortestpurposes.Mustbeturnedoff
byacommand.TheCLIisstillactivewhilethemodeisontoallow
monitoringofvariousparameters.

DuringIFanddigitalloopback,thetransmittersignalfromthefarendwill
stillbepresentattheinputtotheIDUandmaycauseapoorresult.
Therefore,theodupowerOFFontheremoteendofmayberequiredto
eliminateanysignalfromthefarendwhichmaycorrupttheresult.

Allloopbackmodeswillstoplivetrafficfrompassingacrossthelink

model

SYNTAX

model

Default:N/A

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

152

ConfigurationStorage:No

DESCRIPTION

DisplaycurrentODU/IDUmodelandserialID.

Thefollowinginformationarebeendisplayed:ODUmodel,IDUmodel,
ODUSerialID,IFRev,IFSerial,IDUModel,IDUSerialIDforeachradio

mse

SYNTAX

Mse
mse<duration>:durationrangefrom199seconds

Default:defaultduration=1second
ConfigurationStorage:NO
msewithoutanyparameterwilldisplaythecurrentmsevalueforthe
receivedsignal.

DESCRIPTION

msecommandisusedtomonitortheMeanSquareError(MSE)ofthelink
receivedsignalbasedonthespecifiedduration.CLIpromptwillnotbe
accessiblewhilelinktestisrunning.

oduled

SYNTAX

TrangoSystems,Inc.

oduled

GigaPlusUserManualRev1.3

153

oduled<on|off>

Default:ON
ConfigurationStorage:YES
oduledwithoutanyparameterwilldisplaythecurrentstatusofODULED
display

DESCRIPTION

TurnON/OFFODUledfordisplayRSSIvalue.AppliesonlytoSPODUs

odupower

SYNTAX

odupower
odupower<on|off>

Default:OFF
ConfigurationStorage:Yes
odupowerwithoutanyparameterwilldisplaythecurrentstatusofODU
power.

DESCRIPTION

ThecommandisusedtoTurnON/OFFodupower.
TheODUispoweredfromtheIDUovertheIFcablewith48VDC

ItisrecommendedtoturnofftheODUpowerduringinitialinstallingofthe
ODUonthetowerandothermaintenance

TheresponsetimeforODUpowerONwillvarydependingupontheODU

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

154

model.ItislongerforHPODUs

odurxagc

SYNTAX

odurxagc<on|off>

DEFAULTVALUE

Off

DESCRIPTION

Thecommandisusedtosettheodurxgaincontrolloopinthesystem.This
controlsthereceivelevelintotheIDUfromtheODUandkeepsthe
receivedlevelwithinapredefinedrange.ThishelpstoimproveMSEand
maintainbettersystemperformanceinfadingconditions.

ApplicableonlyforSPODU[6,11,11E,18,18EModel]

EXAMPLE

ToturnON/OFFodurxagcloop
(trangoconfig)#odurxagcon
ODURxAGC:on

SUCCESS

Toviewcurrentodurxagcstatus:
(trangoconfig)#odurxagc
ODURxAGC:off

RELATED

targetrssi,cableloss

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

155

opmode

SYNTAX

opmode
opmode<on|off>

Default:OFF
ConfigurationStorage:NO
opmodewithoutanyparameterwilldisplaythecurrentstatusofODU
operationmode

DESCRIPTION

OpmodecommandisusedtoenablethetransmitterontheODU.
Opmodesettingsarenotpersistentacrossreboot.Seedefault_opmode
command

freqandspeedsettingsarerequiredtobesettovalidvaluebefore
opmodecanbeturnedON.

passwd

SYNTAX

Passwd<new_password><confirm_password>

Default:N/A.Defaultconfignodepasswdistrango
ConfigurationStorage:Yes
passwdisasystemlevelcommand.
<new_password>mustbeatleast4charactersandnomorethan10

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

156

characters
<new_password>and<confirm_password>mustbeidenticalforthenew
passwordtotakeeffect

DESCRIPTION

Updatethecurrentpasswordforenteringconfignode.Thenew
paswordtakeseffectonlyafterarebootcommandorreentertheview
nodefromdebugpromptwithcli command.

port

SYNTAX

porteth<16>auto_negotiate<on|off>
porteth<16>duplex<half|full>
porteth<16>enable<on|off>
porteth<16>maxrate<01000>
porteth<16>pause<on|off>
porteth<16>priority<07>
porteth<16>speed<01000>

DESCRIPTION

ThiscommandisusedtosetEthernetportsettings.Ethernet:auto
negotiation,enable/disable,speed,priority,pauseframe,duplexandmax
rate.

Speed/Duplex/AutoNegotiateisfixedforge3/ge4whichareGigEFiber

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

157

portsandthesesettingarenotconfigurable

power

SYNTAX

power
power<030>

Default:10dBm
ConfigurationStorage:Yes
opmodewithoutanyparameterwilldisplaythecurrentstatusofODU
transmitpowerlevel

DESCRIPTION

PowercommandisusedtosettheODUtransmitpowerlevel.The
maximumlevelisdependentuponthemodulationandODUmodel.

Ensurethatthepowerdoesnotexceedtheratingforthemodulationbeing
usedorsignaldistortionwilloccur.SPODUlevelsareshownherefor
refrence.

SPODUModel
18,18E

6,6E,11,11E

TrangoSystems,Inc.

Modulation
QAM256
QAM128
QAM64
QAM256
QAM128
QAM64
QAM32

GigaPlusUserManualRev1.3

MaxTxpower
17
18
19
19
20
21
22
158

23,23E

15E

QAM256
QAM16
QPSK
QPSK
QAM16
QAM64
QAM128

17
19
20
23
22
21
20

TheusercannotchangepowerwhenATPCisON.

prompt
SYNTAX

promt<prompt_str>

Default:CLI
ConfigurationStorage:Yes
promptisasystemlevelcommand.

DESCRIPTION

TrangoSystems,Inc.

PromptcommandisusedtoupdatetheCLIpromptwithmoredescriptive
nameofthesystem.Defaultpromptsare<CLIview>,<CLIconfig>.The
usermayupdatetoastringthatismoremeaningful.

GigaPlusUserManualRev1.3

159

reboot

SYNTAX

reboot

Default:N/A
ConfigurationStorage:No
rebootisasystemlevelcommand.

DESCRIPTION

Rebootsentiresystemincludingdatapath.Noconfigurationchangesafter
thesystemreboot.

remark

SYNTAX

remark
remark[system_remark]

Default:Remark=TrangoGigPlus
ConfigurationStorage:Yes

DESCRIPTION

Remarkofthesystemtypicallyusedforidentificationpurposes.

Devicestringisusedtodisplaythedevicenameonthetopoftherowfor
allthedevicelevelparameters.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

160

reset
SYNTAX

resetconfig
resetipconfig
resetlicense_key

Default:N/A
ConfigurationStorage:No
resetisasystemlevelcommand.

DESCRIPTION

resetconfig:Restoreallfactorydefaultconfigurationsettingincluding
resettingpasswordforsystemlogin,CLIconfignode,Webinterfacelogin.
ExcludinglicensekeyandIPconfiguration.

Arebootofthesystemisrequiredforthecommandtotakeeffect.

resetipconfig:ResetonlytheIPconfigurationtodefault.

resetlicense_key:Removeupto5licensekeys.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

161

rps

SYNTAX

rps<on|off>
Default:OFF
ConfigurationStorage:Yes

rpswithoutanyparameterwilldisplaythecurrentstatusofRapidPort
Shutdownfeaturestatus.

DESCRIPTION

ThiscommandisusedtoconfigureRapidPortShutdown(RPS)
functionality.TheRPSsettingneedstobethesameonbothsideofthelink
forproperoperation.

IftheRPSisenabledthedataports(GigE)onbothsideofthelinkare
immediatelyshutdownintheeventofalinklossinordertoprovideafast
switchovermechanismtotheexternalroutersandswitches.

RELATED

Sysinfo

rssi

SYNTAX

rssi<iteration>
Iterationrangefrom199seconds

Default:defaultiteration=1second

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

162

ConfigurationStorage:NO
rssiwithoutanyparameterwilldisplaythecurrentmsevalue
DESCRIPTION

rssicommandisusedtomonitorthereceivedsignallevel.Itisusedto
monitorthelink,basedonthespecifiedduration.CLIpromptwillnotbe
accessiblewhilerssicommandisrunning.

RSSIvaluerangeshouldbebetween90and30

ForsomeSPODUs,theRSSIvaluewillnotdisplaybelow65dBm
accurately,soforantennaalignmentpurposestheMSEcanbeusedasa
guideuntilthesignalisacquired.SeetheAntennaAlignmentSectionfor
moreinformation

siglevel
SYNTAX

DESCRIPTION

siglevel

Default:N/Q
ConfigurationStorage:No

Siglevelwilldisplaythesignallevelrelatedparameterformodem1

Thiscommandisusedtoassistdebugginganysignalpathrelatedissue.

IDURSSI:idurssionthemodemlevel.

NomralizeMSE/RadialMSE:
NormMSE=RadialMSEphasenoiseresidueisminimal
NormMSE>RadialMSEthereissomeamplitudenoise(AM
distortion)
NormMSE<RadialMSEphasenoiseresidueexist,thatthePLLdid
notfullycorrect

UncorrectBlock:Errorreportedbymodemwhenpassingtraffics.

Powersensors:usedtomakesureTXpoweraccuracy.Somemodels
usesonlyIFwhileotherusingonlytheRFvalues.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

163

Oduattn:Makesuretheattenuatorsarebeensetcorrectly.

Note:Blockcounter&uncorrectblockcounterareaccumulative
valuessincethelastlinkestablishment.Theyarecollectedona20
secondperiodicbasis.

(CLIview)#siglevel
IDURSSI:0
NormalizedMSE:348
RadialMSE:340
LDPCDecoderStress:0
ExternalAGC:1604
CarrierOffset:2466
RxSymrate:49500732
BlockCounter:0
UncorrectBlock:0
LDPCAvgIteration:0
Outputcorrectedbytes:0
ReturnLoss:0x0000
TxPoweralarm:ok
TxPAalarm:ok
PAon/offalarm:on
TxPowerRangealarm:ok
TxPoweractual:20.00
RxPoweractual:23.00
Channeltest:Pass
Telemetrydebug:Fail
(CLIview)#

EXAMPLE

snmpd

SYNTAX

snmpd
snmpd<on|off>

Default:ON

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

164

ConfigurationStorage:No.AlwaysONatsystembootup.

snmpdwithoutanyparameterwilldisplaythecurrentstatusforthe
tftpddaemon

DESCRIPTION

Turnon/offsnmpdagentontheradio.Mustbeontoperformany
SNMPget/set.

EXAMPLE

Toturnsnmpdoff
(trangoconfig)#snmpdoff
snmpd:off

SUCCESS

RELATED

Ipconfig,snmptrap,trapip

speed

SYNTAX

speed<bandwidth><modulation>
<bandwidth>:4,7,10,14,20,28,30,40,50,56,80
<modulation>:qpsk,qam16,qam32,qam64,qam128,qam256

Default:bandwidth20,QAM128
ConfigurationStorage:Yes

speedwithoutanyparameterwilldisplaythecurrentspeedsetting

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

165

DESCRIPTION

LoadthecorrespondingthemodembinaryandconfigureTxandRx
bandpassfilters.

Thespeedcommandwillalsoconfigurethemodemprotectionmode
basedonthesystem_modeconfiguration.Onlywhenthe1+1HSBmodeis
set,themodemmaybeconfiguredasworkingorprotectionmode.

Binariesselectionforthespeedcommandisbasedon5different
configuration:tdm_mode,acmenable,modulationandbandwidth.

Makingchangesviathetdm_mode,oracmenablecommandswill
requireasubsequentreloadofthespeedsettingforproperoperation.

Symrate

Modulation

TXBPF

RXBPF

Speed

Symrate

Licensekey

QPSK

18.75

22

10

3.50

None

QPSK

18.75

22

10

5.6

None

10

QPSK

18.75

22

15

8.32

None

14

QPSK

18.75

22

22

12.20

None

20

QPSK

30

38

30

17.42

None

28

QPSK

30

38

46

26

None

30

QPSK

50

39

46

26

None

40

QPSK

50

66

64

35.42

None

50

QPSK

75

66

77

43

None

56

QPSK

75

66

88

49.50

None

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

166

80

QPSK

75

66

88

49.50

None

16QAM

18.75

22

10

3.0

None

16QAM

18.75

22

10

5.6

None

10

16QAM

18.75

22

30

8.32

None

14

16QAM

18.75

22

42

12.20

None

20

16QAM

30

38

63

17.42

None

28

16QAM

30

38

94

26

None

30

16QAM

50

39

94

26

None

40

16QAM

50

66

128

35.42

Key1

50

16QAM

75

66

156

43

Key1

56

16QAM

75

66

179

49.50

Key1

80

16QAM

75

66

179

49.50

Key1

32QAM

18.75

22

37

3.0

None

32QAM

18.75

22

37

5.6

None

10

32QAM

18.75

22

37

8.32

None

14

32QAM

18.75

22

52

12.20

None

20

32QAM

30

38

79

17.42

None

28

32QAM

30

38

117

26

Key1

30

32QAM

50

39

117

26

Key1

40

32QAM

50

66

159

35.42

Key1

50

32QAM

75

66

195

43

Key1

56

32QAM

75

66

227

49.50

Key2

80

32QAM

75

66

227

49.50

Key2

64QAM

18.75

22

45

3.0

None

64QAM

18.75

22

45

5.6

None

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

167

10

64QAM

18.75

22

45

8.32

None

14

64QAM

18.75

22

64

12.20

None

20

64QAM

30

38

95

17.42

None

28

64QAM

30

38

142

26

Key1

30

64QAM

50

39

142

26

Key1

40

64QAM

50

66

194

35.42

Key1

50

64QAM

75

66

236

43

Key2

56

64QAM

75

66

272

49.50

Key2

80

64QAM

75

66

272

49.50

Key2

128QAM

18.75

22

52

3.0

None

128QAM

18.75

22

52

5.6

None

10

128QAM

18.75

22

52

8.32

None

14

128QAM

18.75

22

75

12.20

None

20

128QAM

30

38

110

17.42

None

28

128QAM

30

38

165

26

Key1

30

128QAM

50

39

165

26

Key1

40

128QAM

50

66

226

35.42

Key2

50

128QAM

75

66

275

43

Key2

56

128QAM

75

66

315

49.50

Key2

80

128QAM

75

66

315

49.50

Key2

256QAM

18.75

22

60

3.0

None

256QAM

18.75

22

60

5.6

None

10

256QAM

18.75

22

60

8.32

None

14

256QAM

18.75

22

86

12.20

None

20

256QAM

30

38

126

17.42

Key1

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

168

28

256QAM

30

38

188

26

Key1

30

256QAM

50

39

188

26

Key1

40

256QAM

50

66

258

35.42

Key2

50

256QAM

75

66

314

43

Key2

56

256QAM

75

66

366

49.50

Key2

80

256QAM

75

66

375

49.50

Key2

status

SYNTAX

statusmodem
statuspll
statusport
statustdm
statusclear

Default:N/A
ConfigurationStorage:No
statusisasystemlevelcommand.

DESCRIPTION

Statusmodem:displaymodemlinkstatus.MSE,RSSI,BER,FER

Statuspll:displayODU/IDUplllockstatus.

Statusport:displayEthernetcountersforeachports,RFcounters
andportutilizations.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

169


statustdm:displayT1/E1countersanderrorstatus

statusclear:clearallEthernet,RF,TDMcountersandport
utilization.

sync

sync

Default:N/A
ConfigurationStorage:N/A

syncwithoutanyparameterwillperformsynchronizationprocedure
betweenActiveandStandbyunit

synccommandonlyallowedtobeinitiatedonActiveunit.

SYNTAX

DESCRIPTION

syncisusedtoperformsynchronizationproceduretosyncup
configurationparametersbetweenActiveandStandbyunits.There
aresomeparameterswhichareindependentofutypeandtherefore,
willnotbesynchronizedwiththiscommand.Thefollowing
commandsaretheonesthat,ifexecuted,preventachievingsync
withtheStandbyunit:

Alarm,alignment,cableloss,fanctrl,ibm,ipconfig,licensekey,
loopbackmode,opmode,tftpdandtraps.

sync_state

SYNTAX

TrangoSystems,Inc.

sync_state

GigaPlusUserManualRev1.3

170

Default:N/A
ConfigurationStorage:N/A

sync_statewithoutanyparameterwilldisplaysynchronizationstatus

DESCRIPTION

sync_stateisusedtodisplaythecurrentsynchronizationstatus
betweenActiveandStandbyunit.

Thefollowingparameterswillnotbesynchronized.

Alarm,alignment,cableloss,fanctrl,ibm,ipconfig,licensekey,
loopbackmode,opmode,tftpdandtraps

sysinfo

SYNTAX

sysinfo
sysinfo<06>

Default:N/A
ConfigurationStorage:No
sysinfowithoutanyparameterwilldisplaythecurrentIDUandODU
configurationparameters.
sysinfotakesaparameterforinformationcategory:0=versioninfo,
1=Management,2=RadioConfig,3=SystemConfig,4=Ethernet
5=ACM,6=thresholdsettings

sysinfoisasystemlevelcommand.

DESCRIPTION

TrangoSystems,Inc.

ViewthecurrentconfigurationstatusofthelocalsideIDUandODU.
Toselectasubsetoftheentiresysteminfo,addtheargument0
through6afterthesysinfocommand

GigaPlusUserManualRev1.3

171

syslog

SYNTAX

syslog
syslog[02]
syslogclear
syslogexport

Default:0:SET,1:EVENT
ConfigurationStorage:Yes
syslogwithoutanyparameterwilldisplayallthesystemlogmessage
forupto3000lines.
syslogtakesaparameterforloglevel:0=SET,1=EVENT,2=STAT

syslogexport,exportthesyslogtoasyslog.txtfilewhichcanbetftp
bycustomer.

syslogisasystemlevelcommand.

DESCRIPTION

syslog:willdisplayallthesystemlogentriesthathavebeen
recordedsincethebootup.

syslogclear:Clearallsyslog.Only3000logentrieswillbecaptured

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

172

andwillwraparoundwhenoverflows.

targetrssi

SYNTAX

targetrssi
targetrssi<3080>

Default:40
ConfigurationStorage:YES
targetrssiwithoutanyparameterwilldisplaythetargetrssiofthe
ODU

DESCRIPTION

ConfigurethetargetRSSIlevelthattheATPCandODUgaincontrol
willtrytomaintain.Thenumbershouldbe23dBbelowthe
expectedRSSIbasedonpathcalculations.

tdm

SYNTAX

tdm

Default:N/A
ConfigurationStorage:No

DESCRIPTION

DisplayTDMportmodeandcoding
ForE1:HDB3
ForT1:AMIorB8ZS

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

173

EXAMPLE

(CLIconfig)#tdm
TDMMode:ETHonly
TDMCoding:HDB3

telnetd
SYNTAX

telnetd
telnetd<on|off>

Default:telnetdOFF.
ConfigurationStorage:Yes
telnetdwithoutanyparameterwilldisplaythecurrentstatusforthe
telnetddaemon
telnetdisasystemlevelcommand.

DESCRIPTION

Linuxsystemcommandtostartthetelnetddaemon

temp
SYNTAX

temp

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

174

Default:N/A
ConfigurationStorage:No
tempwithoutanyparameterwilldisplaythecurrentIDUandODU
temperatures.
tempisasystemlevelcommand.
Displayofthisstatusisthroughsharedmemory.

DESCRIPTION

ViewthecurrenttemperaturesofIDUandODU.Thetemperature
reportedisthetemperatureinsidetheunitindegreesCelcius

tftpd

SYNTAX

tftpd
tftpd<on|off>

Default:tftpdOFF.
ConfigurationStorage:Yes
tftpdwithoutanyparameterwilldisplaythecurrentstatusforthe
tftpddaemon
tftpdisasystemlevelcommand.

DESCRIPTION

Turnonthetftpserver.Usedtotransferdiagnosticfile,configuration
fileandsoftwareimagesduringupgrades.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

175

threshold

SYNTAX

threshold

Defaults:seethetablebelow.

parameters

min

max

Action

RSSI

85

20

none

MSE

45

15

none

BER

0.00E+0

1.00E4

none

BER

0.00E+0

1.00E4

none

IDUtemp

10

55

none

ODUtemp

40

58

none

Inportutil

0.0

100.0

none

Outportutil

0.0

100.0

none

ConfigurationStorage:Yes
thresholdwithoutanyparameterwilldisplaythecurrentstatusfor
thresholdsettinginformation
thresholdisadevicelevelcommand.

DESCRIPTION

thresholdcommandisusedtosetrulesformonitoringthesystem.
Wheneverthethresholdexceedstheprogrammedvaluesthedesired
actionisset.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

176

Theutilizationrateisexpressedaspercentageofthecurrentmax
speedbasedonthemodulation.

trap

SYNTAX

trap
trapenable<trap#><on|off>
trapip<trap#><ip_addr>

Default:seetable6.5

trap#

IP

enable

Trap1manager

0.0.0.0

OFF

Trap2manager

0.0.0.0

OFF

Trap3manager

0.0.0.0

OFF

Trap4manager

0.0.0.0

OFF

Trap5manager

0.0.0.0

OFF

ConfigurationStorage:Yes
trapwithoutanyparameterwilldisplaythecurrentstatusforthe
snmptrapinformation
trapisasystemlevelcommand.

DESCRIPTION

TrangoSystems,Inc.

trapisusedtoenableandconfiguretrapsandtheIPaddresswhich
theywillbesentto

GigaPlusUserManualRev1.3

177

uptime

SYNTAX

Uptime

DEFAULTVALUE

N/A

DESCRIPTION

Uptimeisusedtodisplayhowlongthesystemhasbeenrunning,since
thelastreboot/powercycle.

Itshowsthecurrenttimeanduptime.

EXAMPLE

Todisplaycurrentuptime
(trangoconfig)#uptime
20:45:58up1:49,loadaverage

RELATED

Date

utype

SYNTAX

utype

Default:N/A
ConfigurationStorage:N/A

utypewithoutanyparameterwilldisplaycurrentutypeandother

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

178

relatedstatus.

DESCRIPTION

EXAMPLE

Utypecommandwilldisplayunitscurrentutype,remoteunitstatus,
electionperiodstatusandsyncstatus.

Currentutype:Noutype,Active,orStandby

Protection:IndicatedifHWswichingprotectionisON/OFF,dependent
uponthestandbylinkstatusandguardtimeprotection.

Remoteunitstatus:nodetection,Standbydetected,activedetected

SyncStatus:Currentconfigurationsynchronizationstatus.
SynchronizedorNotsynchronized.

GuardTime:Currentlyuserconfiguredguardinterval.

FailoverCounter:#oftimestheunitshaveswitchedrolesfromactive
tostandbyandviceaversa

ElectionPeriod:yes(duringelectionperiod),no(notinelection
period)

DebugReg:Fordebugging

(CLIconfig)#utype
Currentutype:active
Protection:off
RedundancyCable:connected
RemoteUnitStatus:standbydetected
SyncStatus:Synchronized
GuardTime:15seconds
FailoverCounter:0
ElectionPeriod:no
DebugReg:(D6)0x00,(D5)0x00,(24)0x1F

utype_switch

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

179

utype_switch

Default:N/A
ConfigurationStorage:N/A

utype_switchdoesnottakeanyinputparameter.Willperformutype
switchfromActivetoStandby.

ThiscommandonlyallowedontheActiveunit.CanNOTbeinitiated
onStandbyunit

SYNTAX

DESCRIPTION

utype_switchmanuallyswitchtheActivetotheStandbyunitby
sendingSwitchoverREQtothestandbyunit.

Thiscommandismainlyusedforimageupgrades.Duringtheimage
upgrades,thestandbyunitcanupgradefirstandwhendone,perform
utype_switchovertomakethecurrentActiveunitStandbytocontinue
theupgradeprocess.

(CLIconfig)#utype
Currentutype:active
Remoteunitstatus:detectingastandby
ElectionPeriod:no
SyncStatus:Synchronized

EXAMPLE

version

Version

SYNTAX

DEFAULTVALUE

N/A

DESCRIPTION
TrangoSystems,Inc.

Versioncommandisusedtodisplaythecurrent/previoussoftware
GigaPlusUserManualRev1.3

180

imagesontheradio.Thesystemiscapableofhavemultipleimages.

RELATED

bootimage

voltage

SYNTAX

voltage

Default:N/A
ConfigurationStorage:No
voltagewithoutanyparameterwilldisplaythecurrentstatusforthe
IDUpowervoltageatdifferentsource
voltageisasystemlevelcommand.

DESCRIPTION

QuerythevoltagelevelatdifferentpowersourceonIDU.The
followingpowersourcearebeinglookat:

V1.25:
V2.5:
V3.3:
V5.0:
V12.0:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

181

AppendixBProductSpecifications
DimensionsandWeight
Parameter
Size

Specification
IDU:1.75x8.75x11.25in
HPODU:10.5x10.5x3.5in
HP2ODU:10.9x9.4x3.6in

Weight

IDU:4.8lbs/2.18kg
HPODU:10.1lbs/4.59kg
HP2ODU:9.5lbs/4.32kg

Environmental
Parameter
OperatingTemperatureRange

Specification
IDU:5degCto+55degC
ODU:40degCto+65degCFunctional
ODU:40degCto+55degCSpecCompliant

StorageTemperature

40degCto+75degC

Humidity

IDU:95%Noncondensing
ODU:100%Condensing

Waterresistance

IDU:NA
ODU:IP65perEN60529

SaltSpray

IDU:NA
ODU:PerIEC/EN6095022

Emissions
Parameter

Specification

ETSIConductedEmissions

EN55022(2006)ClassA

FCCConductedEmissions

FCC15.107(a)ClassA

ETSIRadiatedEmissions

EN55022(2006)ClassA

FCCRadiatedEmissions

FCC15.109(a)ClassA

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

182

Reliability
Parameter
MTBF

Specification
IDU:>18yearscalculated
ODU:>50yearsdemonstrated

ElectromagneticCompliance
Parameter
EMCtestmethods

Specification
EN3014891V1.8(200804)
EN3014894V1.4.1(200902)

PowerLineHarmonics

EN6100032:2006

PowerLineFluctuations/Flicker

EN6100033:2008

ElectrostaticDischarge(ESD)

EN6100042:2009

RadiatedRFimmunity

EN6100043:2004,Radiatedat3V/m

ElectricalFasttransients

EN6100044:2004

PowerLineSurgeImmunity

EN6100045:2006

PowerlineRFconductedimmunity

EN6100046:2005

VoltageDipsandShort
Interruptions

EN610001411:2004

WirelessCompliance
Parameter
FCC

Specification
CFR47Part101
CFR47Part15ClassAunintentionalradiator

Canada

SRSPxx

Europe(Harmonized)

EN30221721
EN30221722

Australia

RALIFX5

NewZealand

PIB22

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

183

WirelessParameters
Parameter

Specification

FrequencyRange

640GHz

ChannelSizesSupported

3.5,7,10,13.75,14,20,27.5,28,30,40,50,55,56,80MHz

FixedModulationSetLevels

QAM256,QAM128,QAM64,QAM32,QAM16,QPSK

TransmitterPowerAccuracy

+/2dB

TransmitterFrequencyAccuracy

+/7ppm

TransmitterCenterFrequency
Synthesizerstepsize

250kHz

TransmitterOutputPower(Muted)

<50dBm

TransmitterOutputReturnLoss

>10dB

AdaptiveModulationSetLevels

QAM256,QAM128,QAM64,QAM32,QAM16

AdaptiveModulationType

ErrorFree,Hitlessthrougheachtransition

AdaptiveModulationTransitions
Thresholds

UserSettable

AutomaticTransmitterPower
Control

>15dBrange,userconfigurablestepsizeandmaxpowerlimit

TransmitterPower

MaximumTransmitPowerbyFrequency(dBm)
Modulation

6,7,8

10

11

13,15

1826

2840

QPSK

30

26.5

28

26

25

23

16QAM

28

22.5

26

23

22

21

32QAM

28

22.5

26

23

22

21

64QAM

25

20.5

22

21

20

17

128QAM

25

20.5

22

21

20

17

256QAM

24

18.5

21

20

19

16

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

184

RadioSensitivity6to26GHz

BW
(Mhz)

Symbol
Rate
(Msps)

ReceiveSensitivityIndBm(626GHz)
QPSK

QAM16

QAM32

QAM64

QAM128

QAM256

96.6

90.4

86.4

84

80.9

77.9

5.6

93.3

87.7

83.7

81.3

78.2

75.2

10

8.32

92.2

86.0

82.0

79.6

76.5

73.5

14

12.2

90.5

84.3

80.3

77.9

74.8

71.8

20

17.42

89.0

82.8

78.8

76.4

73.3

70.3

28/30

26

87.3

81.1

77.1

74.7

71.6

68.6

40

34.83

86.0

79.8

75.8

73.4

70.3

67.3

50

43

85.1

78.9

74.9

72.5

69.4

66.4

55/56/80
49.5
84.5
78.3
*63.8dBmwhensettospeed80qam256

74.3

71.9

68.8

65.8*

RadioSensitivity28to38GHz

BW
(Mhz)

Symbol
Rate
(Msps)

ReceiveSensitivityIndBm(2838GHz)
QPSK

QAM16

QAM32

QAM64

QAM128

QAM256

93.6

87.4

83.4

81.0

77.9

74.9

5.6

90.9

84.7

80.7

78.3

75.2

72.2

10

8.32

89.2

83.0

79.0

76.6

73.5

70.5

14

12.2

87.5

81.3

77.3

74.9

71.8

68.8

20

17.42

86.0

79.8

75.8

73.4

70.3

67.3

28/30

26

84.4

78.1

74.1

71.7

68.6

65.6

40

34.83

83.0

76.8

72.8

70.4

67.3

64.3

50

43

82.1

75.9

71.9

69.5

66.4

63.4

55/56/80
49.5
81.5
75.3
*60.8dBmwhensettospeed80qam256

71.3

68.9

65.8

62.8*

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

185

1+1HotStandbyLinkProtection
Parameter

Specification

FailoverTime

150mSectypical

GuardTime

Userconfigurable10to60seconds

Power
Parameter

Specification

InputVoltageRange

40to72VDC

PowerConsumption

IDU:Max35Wattswithallportsactive
ODU:Typical25Watts,max50Watts

UserInterfaces
Description

Specification

EthernetTrafficPortsand/orIn
BandManagement(IBM)

ETH1andETH2:RJ45Jack10/100/1000BaseT

OutofBandManagement(OBM)

RJ45Jack10/100BaseT

T1/E1Ports18

RJ45Jack

AlarmInputs(2)

05VolthighimpedanceCMOSlevel

AlarmOutputs(2)

DB9Female,50Volt1Amprated,Drycontact

PowerInput

3PositionlatchingscrewterminalBlockwithlockingscrews

Console/CraftPort

DB9Male(requiresCBLDAT3)

1+1RedundancyPort

RJ45Jack(requiresCBLDATRIU3)

RSSIAlignment

BNCFemale(CBLDATRSSIrecommended)

ResetIP/Config

MomentaryPushButtononIDUfrontpanel

RebootSystem

MomentaryPushButtononIDUfrontpanel

Antenna

SlipFitCircularWaveguidefor740GHz

ETH3andETH4:SFP1000BaseTforSFPModule:
SFPGigEC(1000BaseT)
SFPGigES(1000BaseLXSingleModeFiber)
SFPGigEM(1000BaseLXMultimodeFiber)

SlipFitRectangularWaveguidefor6GHz

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

186

EthernetParameters
Parameter

Specification

PacketSize

649600Bytes,IPV4,IPV6

MaxCapacity

L1:414Mbps
L2:375Mbps

DataLatency

<100uSfor64bytepackets,Maxcapacity
(perRFC2544storeandforward)

QoS

802.1pPortPrioritization
Portmappingtoisolateports
VLANPriorityfortaggedpackets:
8ClassesofService
BandwidthShapingperport(IngressRatelimiting)

RSTP

RapidPortShutdownbothendsoflinkwithin50mSecoflinkdrop

T1/E1Parameters
Parameter

Specification

ClockSource

External

T1Compliance

T/O10021993
ITUT.G824
GR499CORE

T1BitRate

1544+/10ppm

T1Impedance

100OhmBalanced

T1LineCode

AMIorB8ZS

E1Compliance

ITUTG.703
ITUTG.823

E1BitRate

2048Kbps+/50ppm

E1Impedance

120OhmBalanced

E1LineCode

HDB3

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

187

AppendixCCableWiring
ThisappendixshowsthewiringofthevariousinterfacesontheGigaPlusunit.

EthernetCabling
TheFiguresbelowshowthecablepinoutsforstraightthroughandcrossoverEthernet
cables.TheimagesbelowconformtoEIA/TIAindustrystandardfor568AandB.
Ifthefirstandsecondpinsareorange,thecableis568B.Ifthefirstandsecondpinsare
green,thecableis568A(Figure46).
IfoneendofthecableisAandtheotherendisBitisacrossovercable.

Figure50EIA/TIA568AStraightthrough

Figure51EIA/TIA568BCrossOver

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

188

T1/E1Cabling
TheFigurebelowshowthecablepinoutsforT1/E1cablingtointerfacetotheRJ45
Jacksonthefrontpanel.

Table14T1/E1CableWiring

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

189

DB9PortInterfaces
DB9ConsolecablePinouts
TheconsolecableisanullmodemcablewithfemaleDB9connectors(Figure48)on
bothsides.ThepinoutsforcreatingaconsolecablearelistedinTable13.Trango
makesacablethatmeetstherequirementsbelowpartnumberCBLDAT3.

Figure52ConsoleCableConnector

ConsoleCablePinouts
IDU

Signal

Direction

PC

1,6

CD

IN

RxD

IN

TxD

OUT

DTR

OUT

1,6

GND

RTS

OUT

CTS

IN

Table15ConsoleCablePinouts

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

190

DB9AlarmPortPinouts
ThealarmportontheIDUisaDB9femaleconnector(Figure49).Thepinoutsofthe
alarmportarelistedinTable14

Figure53AlarmPortPinIdentification

Pins

Function

Relay1Com

Relay1NC

Relay1NO

Input1,05Vinput

Ground

Relay2Com

Relay2NC

Relay2NO

Input1,05Vinput

Table16AlarmPortPinFunctions

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

191

AppendixDMIBOIDListing
MIBIISystem
Object ID
.1.3.6.1.2.1.1.1.0
.1.3.6.1.2.1.1.2.0
.1.3.6.1.2.1.1.3.0
.1.3.6.1.2.1.1.4.0
.1.3.6.1.2.1.1.5.0
.1.3.6.1.2.1.1.6.0

TrangoSystems,Inc.

Name
sysDescr
sysObjectID
sysUpTime
sysContact
sysName
sysLocation

Type
DisplayString
OID
TimeTicks
DisplayString
DisplayString
DisplayString

Access
RO
RO
RO
RO
RO
RO

GigaPlusUserManualRev1.3

Range Limit
N/A
N/A
N/A
N/A
N/A
N/A

Default Value
GigaPlus-1.0
.1.3.6.1.4.1.5454.1.80
N/A
Tech Support
Administrator
USA

192

Trango
Object ID
.1.3.6.1.4.1.5454.1.80.1.1.1
.1.3.6.1.4.1.5454.1.80.1.1.2
.1.3.6.1.4.1.5454.1.80.1.1.3
.1.3.6.1.4.1.5454.1.80.1.1.4
.1.3.6.1.4.1.5454.1.80.1.1.5
.1.3.6.1.4.1.5454.1.80.1.1.6
.1.3.6.1.4.1.5454.1.80.1.2.1
.1.3.6.1.4.1.5454.1.80.1.2.2
.1.3.6.1.4.1.5454.1.80.1.2.3
.1.3.6.1.4.1.5454.1.80.1.2.4
.1.3.6.1.4.1.5454.1.80.1.2.5
.1.3.6.1.4.1.5454.1.80.1.2.6
.1.3.6.1.4.1.5454.1.80.1.3.1
.1.3.6.1.4.1.5454.1.80.1.3.2
.1.3.6.1.4.1.5454.1.80.1.3.3
.1.3.6.1.4.1.5454.1.80.1.3.4
.1.3.6.1.4.1.5454.1.80.1.4.1
.1.3.6.1.4.1.5454.1.80.1.4.2
.1.3.6.1.4.1.5454.1.80.1.4.3
.1.3.6.1.4.1.5454.1.80.1.5.1
.1.3.6.1.4.1.5454.1.80.1.5.2
.1.3.6.1.4.1.5454.1.80.1.5.3
.1.3.6.1.4.1.5454.1.80.1.5.4
.1.3.6.1.4.1.5454.1.80.1.6.1
.1.3.6.1.4.1.5454.1.80.1.7.1
.1.3.6.1.4.1.5454.1.80.1.7.2
.1.3.6.1.4.1.5454.1.80.1.7.3
.1.3.6.1.4.1.5454.1.80.1.7.4
.1.3.6.1.4.1.5454.1.80.1.7.5
.1.3.6.1.4.1.5454.1.80.1.8.1
.1.3.6.1.4.1.5454.1.80.1.8.2
.1.3.6.1.4.1.5454.1.80.1.8.3
.1.3.6.1.4.1.5454.1.80.1.9.1.1
.1.3.6.1.4.1.5454.1.80.1.9.1.2
.1.3.6.1.4.1.5454.1.80.1.9.2.1
.1.3.6.1.4.1.5454.1.80.1.9.2.2
.1.3.6.1.4.1.5454.1.80.1.9.3.1
.1.3.6.1.4.1.5454.1.80.1.9.3.2
.1.3.6.1.4.1.5454.1.80.1.9.4.1
.1.3.6.1.4.1.5454.1.80.1.9.4.2
.1.3.6.1.4.1.5454.1.80.1.9.5.1
.1.3.6.1.4.1.5454.1.80.1.9.5.2
.1.3.6.1.4.1.5454.1.80.1.10.1
.1.3.6.1.4.1.5454.1.80.1.10.2
.1.3.6.1.4.1.5454.1.80.1.10.3

Name
sysFPGAVer
sysOSVer
sysFWVer
sysPICVer
sysModemVer
sysODUFWVer
sysFPGAPreVer
sysOSPreVer
sysFWPreVer
sysPICPreVer
sysModemPreVer
sysODUFWPreVer
sysIDUModel
sysIDUSerialID
sysODUModel
sysODUSerialID
sysMACeth1
sysMACeth2
sysReserved1
sysIpAddress
sysSubnetMask
sysDefaultGateway
sysRemoteIp
sysRemarkSystem
sysIBMEnable
sysIBMIp
sysIBMNetmask
sysIBMVlanID
sysIBMVlanPort
sysSNMPReadCommStr
sysSNMPWriteCommStr
sysSNMPTrapCommStr
sysSNMPTrap1Enable
sysSNMPTrap1Ip
sysSNMPTrap2Enable
sysSNMPTrap2Ip
sysSNMPTrap3Enable
sysSNMPTrap3Ip
sysSNMPTrap4Enable
sysSNMPTrap4Ip
sysSNMPTrap5Enable
sysSNMPTrap5Ip
sysImageUpgrade
sysImageUpgradeStatus
sysImageToggle

Type
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
Integer
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
IpAddr
IpAddr
IpAddr
IpAddr
DisplayString
Integer
IpAddr
IpAddr
Integer
Integer
DisplayString
DisplayString
DisplayString
Integer
IpAddr
Integer
IpAddr
Integer
IpAddr
Integer
IpAddr
Integer
IpAddr
Integer
Integer
Integer

Access
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RO
RW

.1.3.6.1.4.1.5454.1.80.1.11
.1.3.6.1.4.1.5454.1.80.1.12.1
.1.3.6.1.4.1.5454.1.80.1.12.2
.1.3.6.1.4.1.5454.1.80.1.13.1
.1.3.6.1.4.1.5454.1.80.1.13.2
.1.3.6.1.4.1.5454.1.80.1.14

sysConfigOption
sysDiagnostic
sysDiagnosticStatus
sysSyslogExport
sysSyslogLevel
sysReboot

Integer
Integer
Integer
Integer
Integer
Integer

RW
RW
RO
RW
RW
RW

.1.3.6.1.4.1.5454.1.80.1.15

sysResetOption

Integer

RW

.1.3.6.1.4.1.5454.1.80.1.16
.1.3.6.1.4.1.5454.1.80.1.17.1
.1.3.6.1.4.1.5454.1.80.1.17.2

sysDatapath
sysAlarm1
sysAlarm2

Integer
Integer
Integer

RW
RW
RW

.1.3.6.1.4.1.5454.1.80.1.18

sysFanCtrl

Integer

RW

Range Limit
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
string size 1..100
0(Off), 1(On)
string size 16 (A.B.C.D)
string size 16 (A.B.C.D)
0-4090
1 4
string size 1-32
string size 1-32
string size 1-32
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
0(Off), 1(On)
string size 16 (A.B.C.D)
1(IDU), 2(ODU)
0(NA), 1(Failed)
1(Toggle)
1(Export), 2(Import),
3(Remove), 4(Save)
1(Export)
0(NA), 1(Failed)
1(Export), 2(Clear)
1(REBOOT)
0(Factory Default), 1(IP),
2(License)
0(ETH only), 1(ETH+T1),
2(ETH+E1)
0(Off), 1(On)
0(Off), 1(On)
0(FanOff), 1(Fan1On), 2
(Fan2On)

Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
192.168.100.100
255.255.255.0
192.168.100.100
0.0.0.0
TrangoLink GigaPro
0(Off)
172.168.1.1
255.255.0.0
1
ge1
public
private
trapstr
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0 (NA)
0(NA)
0(NA)
0(NA)
0(NA)
0(NA)
0(NA)
3
0 (NA)
0 (NA)
0(ETH only)
0(Off)
0(Off)
1(Fan1On)

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

193

Trango,contd
.1.3.6.1.4.1.5454.1.80.1.19
.1.3.6.1.4.1.5454.1.80.1.20.1
.1.3.6.1.4.1.5454.1.80.1.20.2
.1.3.6.1.4.1.5454.1.80.1.20.3
.1.3.6.1.4.1.5454.1.80.1.20.4
.1.3.6.1.4.1.5454.1.80.1.20.5
.1.3.6.1.4.1.5454.1.80.1.21
.1.3.6.1.4.1.5454.1.80.1.22
.1.3.6.1.4.1.5454.1.80.1.23.1
.1.3.6.1.4.1.5454.1.80.1.23.2
.1.3.6.1.4.1.5454.1.80.1.24.1.1
.1.3.6.1.4.1.5454.1.80.1.24.1.2
.1.3.6.1.4.1.5454.1.80.1.24.1.3
.1.3.6.1.4.1.5454.1.80.1.24.2.1
.1.3.6.1.4.1.5454.1.80.1.24.2.2
.1.3.6.1.4.1.5454.1.80.1.25

sysIDUTemp
sysReserved2
sysHTTPD
sysSNMPD
sysTFTPD
sysTelnetD
sysRPSEnable
sysClearCounter
sysTdmMode
sysTdmCoding
sysSpeedLicenseEnable
sysSpeedLicenseKey1
sysSpeedLicenseKey2
sysTDMLicenseEnable
sysTDMLicenseKey
sysIDULED

Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
String
String
Integer
String
Integer

RO
RW
RW
RO
RW
RW
RW
RW
RO
RO
RO
RW
RW
RO
RW
RW

.1.3.6.1.4.1.5454.1.80.1.26

sysFailoverMode

Integer

RW

.1.3.6.1.4.1.5454.1.80.1.27
.1.3.6.1.4.1.5454.1.80.1.28
.1.3.6.1.4.1.5454.1.80.1.29.1
.1.3.6.1.4.1.5454.1.80.1.29.2
.1.3.6.1.4.1.5454.1.80.1.29.3
.1.3.6.1.4.1.5454.1.80.1.29.4
.1.3.6.1.4.1.5454.1.80.1.30

sysUtype
sysSync
sysRemoteLinkStatus
sysRemoteODUStatus
sysRemoteRSSI
sysRemoteMSE
sysGuardTime

Integer
Integer
Integer
Integer
Integer
Integer
Integer

RO
RW
RO
RO
RO
RO
RW

TrangoSystems,Inc.

N/A
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
1(Clear)
0(T1), 1(E1)
0(AMI), 1(B8ZS), 2(HDB3)
0(Disable), 1(Enable)
N/A
N/A
0(Disable), 1(Enable)
N/A
0(RSSI), 1 (TDM)
0(Off), 1(ON with port OFF),
2(ON with port ON)
0(NO Utype), 1 (Active),
2(Standby)
1(sync)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
N/A
N/A
10-60 seconds

GigaPlusUserManualRev1.3

N/A
0(Off)
1(On)
1(On)
0(Off)
1(On)
0(Off)
0(NA)
0(T1)
0(AMI)
0(Disable)
N/A
N/A
0(Disable)
N/A
0(RSSI)
0
1(Active)
N/A
N/A
N/A
N/A
N/A
15 second

194

ModemSection
Object ID
.1.3.6.1.4.1.5454.1.80.2.1
.1.3.6.1.4.1.5454.1.80.2.2
.1.3.6.1.4.1.5454.1.80.2.3.1
.1.3.6.1.4.1.5454.1.80.2.3.2.1
.1.3.6.1.4.1.5454.1.80.2.3.2.2
.1.3.6.1.4.1.5454.1.80.2.3.2.3
.1.3.6.1.4.1.5454.1.80.2.3.2.4
.1.3.6.1.4.1.5454.1.80.2.3.2.5
.1.3.6.1.4.1.5454.1.80.2.3.2.6
.1.3.6.1.4.1.5454.1.80.2.3.3.1.1
.1.3.6.1.4.1.5454.1.80.2.3.3.1.2
.1.3.6.1.4.1.5454.1.80.2.3.3.2.1
.1.3.6.1.4.1.5454.1.80.2.3.3.2.2
.1.3.6.1.4.1.5454.1.80.2.3.3.3.1
.1.3.6.1.4.1.5454.1.80.2.3.3.3.2
.1.3.6.1.4.1.5454.1.80.2.3.3.4.1
.1.3.6.1.4.1.5454.1.80.2.3.3.4.2
.1.3.6.1.4.1.5454.1.80.2.3.3.5.1
.1.3.6.1.4.1.5454.1.80.2.3.3.5.2
.1.3.6.1.4.1.5454.1.80.2.3.3.6.1
.1.3.6.1.4.1.5454.1.80.2.3.3.6.2
.1.3.6.1.4.1.5454.1.80.2.3.4.1.1
.1.3.6.1.4.1.5454.1.80.2.3.4.1.2
.1.3.6.1.4.1.5454.1.80.2.3.4.2.1
.1.3.6.1.4.1.5454.1.80.2.3.4.2.2
.1.3.6.1.4.1.5454.1.80.2.3.4.3.1
.1.3.6.1.4.1.5454.1.80.2.3.4.3.2
.1.3.6.1.4.1.5454.1.80.2.3.4.4.1
.1.3.6.1.4.1.5454.1.80.2.3.4.4.2
.1.3.6.1.4.1.5454.1.80.2.3.4.5.1
.1.3.6.1.4.1.5454.1.80.2.3.4.5.2
.1.3.6.1.4.1.5454.1.80.2.3.4.6.1
.1.3.6.1.4.1.5454.1.80.2.3.4.6.2

Name

Access

modemLoopbackMode
modemDataPattern
modemACMEnable
modemACMProfileQPSKEnable
modemACMProfile16QEnable
modemACMProfile32QEnable
modemACMProfile64QEnable
modemACMProfile128QEnable
modemACMProfile256QEnable
modemACMQPSKMSEImprove
modemACMQPSKMSEImproveInt
modemACM16QMSEImprove
modemACM16QMSEImproveInt
modemACM32QMSEImprove
modemACM32QMSEImproveInt
modemACM64QMSEImprove
modemACM64QMSEImproveInt
modemACM128QMSEImprove
modemACM128QMSEImproveInt
modemACM256QMSEImprove
modemACM256QMSEImproveInt
modemACMQPSKMSEDegrade
modemACMQPSKMSEDegrade
modemACM16QMSEDegrade
modemACM16QMSEDegradeInt
modemACM32QMSEDegrade
modemACM32QMSEDegradeInt
modemACM64QMSEDegrade
modemACM64QMSEDegradeInt
modemACM128QMSEDegrade
modemACM128QMSEDegradeInt
modemACM256QMSEDegrade
modemACM256QMSEDegradeInt

Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer

RW
RW
RW
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW

.1.3.6.1.4.1.5454.1.80.2.3.5.1

modemACMTxProfile

Integer

RO

.1.3.6.1.4.1.5454.1.80.2.3.5.2
.1.3.6.1.4.1.5454.1.80.2.4.1
.1.3.6.1.4.1.5454.1.80.2.4.2
.1.3.6.1.4.1.5454.1.80.2.4.3
.1.3.6.1.4.1.5454.1.80.2.5.1
.1.3.6.1.4.1.5454.1.80.2.5.2
.1.3.6.1.4.1.5454.1.80.2.5.3
.1.3.6.1.4.1.5454.1.80.2.5.4

modemACMRxProfile
modemBER
modemMSE
modemFER
modemLockStatus
modemTimingLock
modemPreambleLock
modemLDPCLock

Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer

RO
RO
RO
RO
RO
RO
RO
RO

Range Limit
0(Off), 1(Digital), 2(IF),
3(Rf_gen), 4(Rf_refl)
0(FPGA), 1(Modem)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
(-45) ~ 0

Default Value

(-45) ~ 0

-25.3

(-45) ~ 0

-26.3

(-45) ~ 0

-29.2

(-45) ~ 0

-32.1

(-45) ~ 0

-32.1

(-45) ~ 0

-17.1

(-45) ~ 0

-18.5

(-45) ~ 0

-21.3

(-45) ~ 0

-24.3

(-45) ~ 0

-27.2

(-45) ~ 0

-27.2

0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
N/A
N/A
N/A
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)

0(Off)
0(FPGA)
0(Off)
1(On)
1(On)
1(On)
1(On)
1(On)
1(On)
-20.3

N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

195

RFSection
Object ID

Access

Range Limit

Default Value

Opaque(Float)

RW

ODU model dependant [In MHz]

Integer

RW

ODU model dependant [in KHz]

Opaque(Float)

RO

ODU model dependant [In MHz]

Integer

RO

ODU model dependant [in KHz]

Name

.1.3.6.1.4.1.5454.1.80.3.1.1.1

rfTxFrequency

.1.3.6.1.4.1.5454.1.80.3.1.1.1

rfTxFrequencyInt

.1.3.6.1.4.1.5454.1.80.3.1.2.1

rfRxFrequency

.1.3.6.1.4.1.5454.1.80.3.1.2.1

rfRxFrequencyInt

.1.3.6.1.4.1.5454.1.80.3.1.3.1

rfFreqDuplex

Opaque(Float)

RW

ODU model dependant [In MHz]

.1.3.6.1.4.1.5454.1.80.3.1.3.1
.1.3.6.1.4.1.5454.1.80.3.2
.1.3.6.1.4.1.5454.1.80.3.3
.1.3.6.1.4.1.5454.1.80.3.4.1
.1.3.6.1.4.1.5454.1.80.3.4.2
.1.3.6.1.4.1.5454.1.80.3.5.1.1
.1.3.6.1.4.1.5454.1.80.3.5.1.2
.1.3.6.1.4.1.5454.1.80.3.5.2.1
.1.3.6.1.4.1.5454.1.80.3.5.2.2
.1.3.6.1.4.1.5454.1.80.3.5.3.1
.1.3.6.1.4.1.5454.1.80.3.5.3.2
.1.3.6.1.4.1.5454.1.80.3.6.1

rfFreqDuplexInt
rfDefaultOpmode
rfOpmode
rfPower
rfPowerInt
rfCableloss140
rfCableloss140Int
rfCableloss350
rfCableloss350Int
rfCableloss915
rfCableloss915Int
rfChannelsWidth

Integer
Integer
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Integer

RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW

0
0(Off)
0(Off)
10
100
0
0
0
0
0
0
20

.1.3.6.1.4.1.5454.1.80.3.6.2
.1.3.6.1.4.1.5454.1.80.3.6.3.1
.1.3.6.1.4.1.5454.1.80.3.6.3.2
.1.3.6.1.4.1.5454.1.80.3.6.4.1
.1.3.6.1.4.1.5454.1.80.3.6.4.2
.1.3.6.1.4.1.5454.1.80.3.7.1
.1.3.6.1.4.1.5454.1.80.3.7.2
.1.3.6.1.4.1.5454.1.80.3.7.3
.1.3.6.1.4.1.5454.1.80.3.8
.1.3.6.1.4.1.5454.1.80.3.9.1

rfModulation
rfSymrate
rfSymrateInt
rfSpeed
rfSpeedInt
rfATPCEnable
rfATPCMaxPower
rfATPCStepSize
rfAlignmentMode
rfTargetRSSI

Integer
Opaque(Float)
Integer
Opaque(Float)
Integer
Integer
Integer
Integer
Integer
Opaque(Float)

RW
RO
RO
RO
RO
RW
RW
RW
RW
RW

ODU model dependant [in KHz]


0(Off), 1(On)
0(Off), 1(On)
0-30
0-300
0-20 [dB]
0-2000 [In 100ths of dB]
0-30 [dB]
0-3000 [100ths of dB]
0-50 [dB]
0-5000 [100ths of dB]
3-100
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q)
N/A

QAM128
24.6

N/A

110

0(Off), 1(On)
ODU model dependant
0-5
0(Off), 1(On)
(-88) ~ (-25)

0(Off)
ODU model dependant
1
0(Off)
-40

.1.3.6.1.4.1.5454.1.80.3.9.2
.1.3.6.1.4.1.5454.1.80.3.10
.1.3.6.1.4.1.5454.1.80.3.11
.1.3.6.1.4.1.5454.1.80.3.12
.1.3.6.1.4.1.5454.1.80.3.13
.1.3.6.1.4.1.5454.1.80.3.14
.1.3.6.1.4.1.5454.1.80.3.15.1
.1.3.6.1.4.1.5454.1.80.3.15.2
.1.3.6.1.4.1.5454.1.80.3.15.3
.1.3.6.1.4.1.5454.1.80.3.15.4
.1.3.6.1.4.1.5454.1.80.3.15.5
.1.3.6.1.4.1.5454.1.80.3.16.1
.1.3.6.1.4.1.5454.1.80.3.16.2
.1.3.6.1.4.1.5454.1.80.3.16.3
.1.3.6.1.4.1.5454.1.80.3.16.4
.1.3.6.1.4.1.5454.1.80.3.16.5
.1.3.6.1.4.1.5454.1.80.3.17.1
.1.3.6.1.4.1.5454.1.80.3.17.2
.1.3.6.1.4.1.5454.1.80.3.17.3
.1.3.6.1.4.1.5454.1.80.3.17.4

rfTargetRSSIInt
rfODULEDEnable
rfODUPowerEnable
rfODURxAGCEnable
rfODUTemp
rfRSSI
rfODURFpll
rfODUIFpll
rfODUTxpll
rfODURxpll
rfIDUTxpll
rfInDataOctets
rfInDataPackets
rfInDropPackets
rfInPortRate
rfInPortUtil
rfOutDataOctets
rfOutDataPackets
rfOutPortRate
rfOutPortUtil

Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32

RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

(-880) ~ (-250) [10ths of dB ??]


0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
N/A
N/A
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

-40
1(On)
0(Off)
0(Off)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

N/A
N/A
N/A
N/A
N/A

196

EthernetSection
Object ID
.1.3.6.1.4.1.5454.1.80.4.1.1.1
.1.3.6.1.4.1.5454.1.80.4.1.1.2
.1.3.6.1.4.1.5454.1.80.4.1.1.3
.1.3.6.1.4.1.5454.1.80.4.1.1.4
.1.3.6.1.4.1.5454.1.80.4.1.1.5
.1.3.6.1.4.1.5454.1.80.4.1.1.6
.1.3.6.1.4.1.5454.1.80.4.1.1.7
.1.3.6.1.4.1.5454.1.80.4.1.1.8
.1.3.6.1.4.1.5454.1.80.4.1.2.1
.1.3.6.1.4.1.5454.1.80.4.1.2.2
.1.3.6.1.4.1.5454.1.80.4.1.2.3
.1.3.6.1.4.1.5454.1.80.4.1.2.4
.1.3.6.1.4.1.5454.1.80.4.1.2.5
.1.3.6.1.4.1.5454.1.80.4.1.2.6
.1.3.6.1.4.1.5454.1.80.4.1.2.7
.1.3.6.1.4.1.5454.1.80.4.1.2.8
.1.3.6.1.4.1.5454.1.80.4.1.2.9
.1.3.6.1.4.1.5454.1.80.4.1.2.10
.1.3.6.1.4.1.5454.1.80.4.2.1.1
.1.3.6.1.4.1.5454.1.80.4.2.1.2
.1.3.6.1.4.1.5454.1.80.4.2.1.3
.1.3.6.1.4.1.5454.1.80.4.2.1.4
.1.3.6.1.4.1.5454.1.80.4.2.1.5
.1.3.6.1.4.1.5454.1.80.4.2.1.6
.1.3.6.1.4.1.5454.1.80.4.2.1.7
.1.3.6.1.4.1.5454.1.80.4.2.1.8
.1.3.6.1.4.1.5454.1.80.4.2.2.1
.1.3.6.1.4.1.5454.1.80.4.2.2.2
.1.3.6.1.4.1.5454.1.80.4.2.2.3
.1.3.6.1.4.1.5454.1.80.4.2.2.4
.1.3.6.1.4.1.5454.1.80.4.2.2.5
.1.3.6.1.4.1.5454.1.80.4.2.2.6
.1.3.6.1.4.1.5454.1.80.4.2.2.7
.1.3.6.1.4.1.5454.1.80.4.2.2.8
.1.3.6.1.4.1.5454.1.80.4.2.2.9
.1.3.6.1.4.1.5454.1.80.4.2.2.10
.1.3.6.1.4.1.5454.1.80.4.3.1.1
.1.3.6.1.4.1.5454.1.80.4.3.1.2
.1.3.6.1.4.1.5454.1.80.4.3.1.3
.1.3.6.1.4.1.5454.1.80.4.3.1.4
.1.3.6.1.4.1.5454.1.80.4.3.1.5
.1.3.6.1.4.1.5454.1.80.4.3.1.6
.1.3.6.1.4.1.5454.1.80.4.3.1.7

Name
gigeEth1AutoNegotiate
gigeEth1Duplex
gigeEth1Enable
gigeEth1MaxRate
gigeEth1PauseFrame
gigeEth1Priority
gigeEth1Speed
gigeEth1Status
gigeEth1InOctets
gigeEth1InUcastPackets
gigeEth1InNUcastPackets
gigeEth1InTotalPackets
gigeEth1OutOctets
gigeEth1OutUcastPackets
gigeEth1OutNUcastPackets
gigeEth1OutTotalPackets
gigeEth1CRCErrors
gigeEth1CollisionErrors
gigeEth2AutoNegotiate
gigeEth2Duplex
gigeEth2Enable
gigeEth2MaxRate
gigeEth2PauseFrame
gigeEth2Priority
gigeEth2Speed
gigeEth2Status
gigeEth2InOctets
gigeEth2InUcastPackets
gigeEth2InNUcastPackets
gigeEth2InTotalPackets
gigeEth2OutOctets
gigeEth2OutUcastPackets
gigeEth2OutNUcastPackets
gigeEth2OutTotalPackets
gigeEth2CRCErrors
gigeEth2CollisionErrors
gigeEth3AutoNegotiate
gigeEth3Duplex
gigeEth3Enable
gigeEth3MaxRate
gigeEth3PauseFrame
gigeEth3Priority
gigeEth3Speed

Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer

Access
RW
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW

Range Limit
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000
0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000
0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000

Default Value
1(On)
1(Full)
1(On)
1000
0(Off)
0
1000
N/A

1(On)
1(Full)
1(On)
1000
0(Off)
0
1000
N/A

1(On)
1(Full)
1(On)
1000
0(Off)
0
1000

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

197

EthernetSection,Contd
.1.3.6.1.4.1.5454.1.80.4.3.1.8
.1.3.6.1.4.1.5454.1.80.4.3.2.1
.1.3.6.1.4.1.5454.1.80.4.3.2.2
.1.3.6.1.4.1.5454.1.80.4.3.2.3
.1.3.6.1.4.1.5454.1.80.4.3.2.4
.1.3.6.1.4.1.5454.1.80.4.3.2.5
.1.3.6.1.4.1.5454.1.80.4.3.2.6
.1.3.6.1.4.1.5454.1.80.4.3.2.7
.1.3.6.1.4.1.5454.1.80.4.3.2.8
.1.3.6.1.4.1.5454.1.80.4.3.2.9
.1.3.6.1.4.1.5454.1.80.4.3.2.10
.1.3.6.1.4.1.5454.1.80.4.4.1.1
.1.3.6.1.4.1.5454.1.80.4.4.1.2
.1.3.6.1.4.1.5454.1.80.4.4.1.3
.1.3.6.1.4.1.5454.1.80.4.4.1.4
.1.3.6.1.4.1.5454.1.80.4.4.1.5
.1.3.6.1.4.1.5454.1.80.4.4.1.6
.1.3.6.1.4.1.5454.1.80.4.4.1.7
.1.3.6.1.4.1.5454.1.80.4.4.1.8
.1.3.6.1.4.1.5454.1.80.4.4.2.1
.1.3.6.1.4.1.5454.1.80.4.4.2.2
.1.3.6.1.4.1.5454.1.80.4.4.2.3
.1.3.6.1.4.1.5454.1.80.4.4.2.4
.1.3.6.1.4.1.5454.1.80.4.4.2.5
.1.3.6.1.4.1.5454.1.80.4.4.2.6
.1.3.6.1.4.1.5454.1.80.4.4.2.7
.1.3.6.1.4.1.5454.1.80.4.4.2.8
.1.3.6.1.4.1.5454.1.80.4.4.2.9
.1.3.6.1.4.1.5454.1.80.4.4.2.10
.1.3.6.1.4.1.5454.1.80.4.7.1
.1.3.6.1.4.1.5454.1.80.4.7.2
.1.3.6.1.4.1.5454.1.80.4.7.3
.1.3.6.1.4.1.5454.1.80.4.7.4
.1.3.6.1.4.1.5454.1.80.4.7.5
.1.3.6.1.4.1.5454.1.80.4.7.6
.1.3.6.1.4.1.5454.1.80.4.7.7
.1.3.6.1.4.1.5454.1.80.4.7.8

TrangoSystems,Inc.

gigeEth3Status
gigeEth3InOctets
gigeEth3InUcastPackets
gigeEth3InNUcastPackets
gigeEth3InTotalPackets
gigeEth3OutOctets
gigeEth3OutUcastPackets
gigeEth3OutNUcastPackets
gigeEth3OutTotalPackets
gigeEth3CRCErrors
gigeEth3CollisionErrors
gigeEth4AutoNegotiate
gigeEth4Duplex
gigeEth4Enable
gigeEth4MaxRate
gigeEth4PauseFrame
gigeEth4Priority
gigeEth4Speed
gigeEth4Status
gigeEth4InOctets
gigeEth4InUcastPackets
gigeEth4InNUcastPackets
gigeEth4InTotalPackets
gigeEth4OutOctets
gigeEth4OutUcastPackets
gigeEth4OutNUcastPackets
gigeEth4OutTotalPackets
gigeEth4CRCErrors
gigeEth4CollisionErrors
gigeEthPriority0COSQueue
gigeEthPriority1COSQueue
gigeEthPriority2COSQueue
gigeEthPriority3COSQueue
gigeEthPriority4COSQueue
gigeEthPriority5COSQueue
gigeEthPriority6COSQueue
gigeEthPriority7COSQueue

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW

GigaPlusUserManualRev1.3

0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)
0(Half), 1(Full)
0(Off), 1(On)
0-1000
0(Off), 1(On)
0-7
0, 100, 1000
0(Off), 1(On)
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-3
0-3
0-3
0-3
0-3
0-3
0-3
0-3

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1(On)
1(Full)
1(On)
1000
0(Off)
0
1000
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0
0
1
1
2
2
3
3

198

TDMSection
Integer

Access
RO

Range Limit
0(Off), 1(On)

Default Value
0(Off)

tdmPort1CableConfig
tdmPort1CounterCrcBlockErrors
tdmPort1CounterExCrcErrors
tdmPort1CounterFBAErrors
tdmPort1CounterFEBErrors
tdmPort1CounterLCViolations
tdmPort1EventLOS
tdmPort1EventLOF
tdmPort1EventAIS
tdmPort1EventTS16AIS
tdmPort1EventRAI
tdmPort1EventRMA
tdmPort1EventLCMFA
tdmPort1EventLSMFA
tdmPort2Status

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)

.1.3.6.1.4.1.5454.1.80.5.2.1.2
.1.3.6.1.4.1.5454.1.80.5.2.2.1
.1.3.6.1.4.1.5454.1.80.5.2.2.2
.1.3.6.1.4.1.5454.1.80.5.2.2.3
.1.3.6.1.4.1.5454.1.80.5.2.2.4
.1.3.6.1.4.1.5454.1.80.5.2.2.5
.1.3.6.1.4.1.5454.1.80.5.2.3.1
.1.3.6.1.4.1.5454.1.80.5.2.3.2
.1.3.6.1.4.1.5454.1.80.5.2.3.3
.1.3.6.1.4.1.5454.1.80.5.2.3.4
.1.3.6.1.4.1.5454.1.80.5.2.3.5
.1.3.6.1.4.1.5454.1.80.5.2.3.6
.1.3.6.1.4.1.5454.1.80.5.2.3.7
.1.3.6.1.4.1.5454.1.80.5.2.3.8
.1.3.6.1.4.1.5454.1.80.5.3.1.1

tdmPort2CableConfig
tdmPort2CounterCrcBlockErrors
tdmPort2CounterExCrcErrors
tdmPort2CounterFBAErrors
tdmPort2CounterFEBErrors
tdmPort2CounterLCViolations
tdmPort2EventLOS
tdmPort2EventLOF
tdmPort2EventAIS
tdmPort2EventTS16AIS
tdmPort2EventRAI
tdmPort2EventRMA
tdmPort2EventLCMFA
tdmPort2EventLSMFA
tdmPort3Status

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)

.1.3.6.1.4.1.5454.1.80.5.3.1.2
.1.3.6.1.4.1.5454.1.80.5.3.2.1
.1.3.6.1.4.1.5454.1.80.5.3.2.2
.1.3.6.1.4.1.5454.1.80.5.3.2.3
.1.3.6.1.4.1.5454.1.80.5.3.2.4
.1.3.6.1.4.1.5454.1.80.5.3.2.5
.1.3.6.1.4.1.5454.1.80.5.3.3.1
.1.3.6.1.4.1.5454.1.80.5.3.3.2
.1.3.6.1.4.1.5454.1.80.5.3.3.3
.1.3.6.1.4.1.5454.1.80.5.3.3.4
.1.3.6.1.4.1.5454.1.80.5.3.3.5
.1.3.6.1.4.1.5454.1.80.5.3.3.6
.1.3.6.1.4.1.5454.1.80.5.3.3.7
.1.3.6.1.4.1.5454.1.80.5.3.3.8

tdmPort3CableConfig
tdmPort3CounterCrcBlockErrors
tdmPort3CounterExCrcErrors
tdmPort3CounterFBAErrors
tdmPort3CounterFEBErrors
tdmPort3CounterLCViolations
tdmPort3EventLOS
tdmPort3EventLOF
tdmPort3EventAIS
tdmPort3EventTS16AIS
tdmPort3EventRAI
tdmPort3EventRMA
tdmPort3EventLCMFA
tdmPort3EventLSMFA

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Object ID
.1.3.6.1.4.1.5454.1.80.5.1.1.1

Name
tdmPort1Status

.1.3.6.1.4.1.5454.1.80.5.1.1.2
.1.3.6.1.4.1.5454.1.80.5.1.2.1
.1.3.6.1.4.1.5454.1.80.5.1.2.2
.1.3.6.1.4.1.5454.1.80.5.1.2.3
.1.3.6.1.4.1.5454.1.80.5.1.2.4
.1.3.6.1.4.1.5454.1.80.5.1.2.5
.1.3.6.1.4.1.5454.1.80.5.1.3.1
.1.3.6.1.4.1.5454.1.80.5.1.3.2
.1.3.6.1.4.1.5454.1.80.5.1.3.3
.1.3.6.1.4.1.5454.1.80.5.1.3.4
.1.3.6.1.4.1.5454.1.80.5.1.3.5
.1.3.6.1.4.1.5454.1.80.5.1.3.6
.1.3.6.1.4.1.5454.1.80.5.1.3.7
.1.3.6.1.4.1.5454.1.80.5.1.3.8
.1.3.6.1.4.1.5454.1.80.5.2.1.1

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

199

TDMSection,Contd
.1.3.6.1.4.1.5454.1.80.5.4.1.1

tdmPort4Status

Integer

RO

0(Off), 1(On)

0(Off)

.1.3.6.1.4.1.5454.1.80.5.4.1.2
.1.3.6.1.4.1.5454.1.80.5.4.2.1
.1.3.6.1.4.1.5454.1.80.5.4.2.2
.1.3.6.1.4.1.5454.1.80.5.4.2.3
.1.3.6.1.4.1.5454.1.80.5.4.2.4
.1.3.6.1.4.1.5454.1.80.5.4.2.5
.1.3.6.1.4.1.5454.1.80.5.4.3.1
.1.3.6.1.4.1.5454.1.80.5.4.3.2
.1.3.6.1.4.1.5454.1.80.5.4.3.3
.1.3.6.1.4.1.5454.1.80.5.4.3.4
.1.3.6.1.4.1.5454.1.80.5.4.3.5
.1.3.6.1.4.1.5454.1.80.5.4.3.6
.1.3.6.1.4.1.5454.1.80.5.4.3.7
.1.3.6.1.4.1.5454.1.80.5.4.3.8
.1.3.6.1.4.1.5454.1.80.5.5.1.1

tdmPort4CableConfig
tdmPort4CounterCrcBlockErrors
tdmPort4CounterExCrcErrors
tdmPort4CounterFBAErrors
tdmPort4CounterFEBErrors
tdmPort4CounterLCViolations
tdmPort4EventLOS
tdmPort4EventLOF
tdmPort4EventAIS
tdmPort4EventTS16AIS
tdmPort4EventRAI
tdmPort4EventRMA
tdmPort4EventLCMFA
tdmPort4EventLSMFA
tdmPort5Status

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)

.1.3.6.1.4.1.5454.1.80.5.5.1.2
.1.3.6.1.4.1.5454.1.80.5.5.2.1
.1.3.6.1.4.1.5454.1.80.5.5.2.2
.1.3.6.1.4.1.5454.1.80.5.5.2.3
.1.3.6.1.4.1.5454.1.80.5.5.2.4
.1.3.6.1.4.1.5454.1.80.5.5.2.5
.1.3.6.1.4.1.5454.1.80.5.5.3.1
.1.3.6.1.4.1.5454.1.80.5.5.3.2
.1.3.6.1.4.1.5454.1.80.5.5.3.3
.1.3.6.1.4.1.5454.1.80.5.5.3.4
.1.3.6.1.4.1.5454.1.80.5.5.3.5
.1.3.6.1.4.1.5454.1.80.5.5.3.6
.1.3.6.1.4.1.5454.1.80.5.5.3.7
.1.3.6.1.4.1.5454.1.80.5.5.3.8
.1.3.6.1.4.1.5454.1.80.5.6.1.1

tdmPort5CableConfig
tdmPort5CounterCrcBlockErrors
tdmPort5CounterExCrcErrors
tdmPort5CounterFBAErrors
tdmPort5CounterFEBErrors
tdmPort5CounterLCViolations
tdmPort5EventLOS
tdmPort5EventLOF
tdmPort5EventAIS
tdmPort5EventTS16AIS
tdmPort5EventRAI
tdmPort5EventRMA
tdmPort5EventLCMFA
tdmPort5EventLSMFA
tdmPort6Status

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)

.1.3.6.1.4.1.5454.1.80.5.6.1.2
.1.3.6.1.4.1.5454.1.80.5.6.2.1
.1.3.6.1.4.1.5454.1.80.5.6.2.2
.1.3.6.1.4.1.5454.1.80.5.6.2.3
.1.3.6.1.4.1.5454.1.80.5.6.2.4
.1.3.6.1.4.1.5454.1.80.5.6.2.5
.1.3.6.1.4.1.5454.1.80.5.6.3.1
.1.3.6.1.4.1.5454.1.80.5.6.3.2
.1.3.6.1.4.1.5454.1.80.5.6.3.3
.1.3.6.1.4.1.5454.1.80.5.6.3.4
.1.3.6.1.4.1.5454.1.80.5.6.3.5
.1.3.6.1.4.1.5454.1.80.5.6.3.6
.1.3.6.1.4.1.5454.1.80.5.6.3.7
.1.3.6.1.4.1.5454.1.80.5.6.3.8

tdmPort6CableConfig
tdmPort6CounterCrcBlockErrors
tdmPort6CounterExCrcErrors
tdmPort6CounterFBAErrors
tdmPort6CounterFEBErrors
tdmPort6CounterLCViolations
tdmPort6EventLOS
tdmPort6EventLOF
tdmPort6EventAIS
tdmPort6EventTS16AIS
tdmPort6EventRAI
tdmPort6EventRMA
tdmPort6EventLCMFA
tdmPort6EventLSMFA

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

200

TDMSection,Contd
.1.3.6.1.4.1.5454.1.80.5.7.1.1

tdmPort7Status

.1.3.6.1.4.1.5454.1.80.5.7.1.2
.1.3.6.1.4.1.5454.1.80.5.7.2.1
.1.3.6.1.4.1.5454.1.80.5.7.2.2
.1.3.6.1.4.1.5454.1.80.5.7.2.3
.1.3.6.1.4.1.5454.1.80.5.7.2.4
.1.3.6.1.4.1.5454.1.80.5.7.2.5
.1.3.6.1.4.1.5454.1.80.5.7.3.1
.1.3.6.1.4.1.5454.1.80.5.7.3.2
.1.3.6.1.4.1.5454.1.80.5.7.3.3
.1.3.6.1.4.1.5454.1.80.5.7.3.4
.1.3.6.1.4.1.5454.1.80.5.7.3.5
.1.3.6.1.4.1.5454.1.80.5.7.3.6
.1.3.6.1.4.1.5454.1.80.5.7.3.7
.1.3.6.1.4.1.5454.1.80.5.7.3.8
.1.3.6.1.4.1.5454.1.80.5.8.1.1

.1.3.6.1.4.1.5454.1.80.5.8.1.2
.1.3.6.1.4.1.5454.1.80.5.8.2.1
.1.3.6.1.4.1.5454.1.80.5.8.2.2
.1.3.6.1.4.1.5454.1.80.5.8.2.3
.1.3.6.1.4.1.5454.1.80.5.8.2.4
.1.3.6.1.4.1.5454.1.80.5.8.2.5
.1.3.6.1.4.1.5454.1.80.5.8.3.1
.1.3.6.1.4.1.5454.1.80.5.8.3.2
.1.3.6.1.4.1.5454.1.80.5.8.3.3
.1.3.6.1.4.1.5454.1.80.5.8.3.4
.1.3.6.1.4.1.5454.1.80.5.8.3.5
.1.3.6.1.4.1.5454.1.80.5.8.3.6
.1.3.6.1.4.1.5454.1.80.5.8.3.7
.1.3.6.1.4.1.5454.1.80.5.8.3.8

TrangoSystems,Inc.

Integer

RO

0(Off), 1(On)

0(Off)

tdmPort7CableConfig
tdmPort7CounterCrcBlockErrors
tdmPort7CounterExCrcErrors
tdmPort7CounterFBAErrors
tdmPort7CounterFEBErrors
tdmPort7CounterLCViolations
tdmPort7EventLOS
tdmPort7EventLOF
tdmPort7EventAIS
tdmPort7EventTS16AIS
tdmPort7EventRAI
tdmPort7EventRMA
tdmPort7EventLCMFA
tdmPort7EventLSMFA
tdmPort8Status

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Integer

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0(Off), 1(On)

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Off)

tdmPort8CableConfig
tdmPort8CounterCrcBlockErrors
tdmPort8CounterExCrcErrors
tdmPort8CounterFBAErrors
tdmPort8CounterFEBErrors
tdmPort8CounterLCViolations
tdmPort8EventLOS
tdmPort8EventLOF
tdmPort8EventAIS
tdmPort8EventTS16AIS
tdmPort8EventRAI
tdmPort8EventRMA
tdmPort8EventLCMFA
tdmPort8EventLSMFA

Integer
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32
Counter32

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

0(0-133), 1(133-266), 2(255399), 3(399-533), 4(533-655)


0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296
0-4294967296

0(0-133)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

GigaPlusUserManualRev1.3

201

Traps
Object ID
.1.3.6.1.4.1.5454.1.80.6.1
.1.3.6.1.4.1.5454.1.80.6.2.1
.1.3.6.1.4.1.5454.1.80.6.2.2
.1.3.6.1.4.1.5454.1.80.6.2.3
.1.3.6.1.4.1.5454.1.80.6.3.1
.1.3.6.1.4.1.5454.1.80.6.3.2
.1.3.6.1.4.1.5454.1.80.6.4.1
.1.3.6.1.4.1.5454.1.80.6.4.2
.1.3.6.1.4.1.5454.1.80.6.4.3
.1.3.6.1.4.1.5454.1.80.6.4.4
.1.3.6.1.4.1.5454.1.80.6.5.1

Name
trapStartUp
trapReboot
trapIPReset
trapConfigReset
trapRPSPortUp
trapRPSPortDown
trapEth1StatusUpdate
trapEth2StatusUpdate
trapEth3StatusUpdate
trapEth4StatusUpdate
trapLinkLock

.1.3.6.1.4.1.5454.1.80.6.5.2

trapACMTxProfileChange

RO

.1.3.6.1.4.1.5454.1.80.6.5.3
.1.3.6.1.4.1.5454.1.80.6.6.1
.1.3.6.1.4.1.5454.1.80.6.6.2
.1.3.6.1.4.1.5454.1.80.6.6.3
.1.3.6.1.4.1.5454.1.80.6.6.4
.1.3.6.1.4.1.5454.1.80.6.6.5
.1.3.6.1.4.1.5454.1.80.6.6.6
.1.3.6.1.4.1.5454.1.80.6.6.7
.1.3.6.1.4.1.5454.1.80.6.6.8
.1.3.6.1.4.1.5454.1.80.6.6.9
.1.3.6.1.4.1.5454.1.80.6.6.10
.1.3.6.1.4.1.5454.1.80.6.6.11
.1.3.6.1.4.1.5454.1.80.6.6.12
.1.3.6.1.4.1.5454.1.80.6.6.13
.1.3.6.1.4.1.5454.1.80.6.6.14
.1.3.6.1.4.1.5454.1.80.6.6.15
.1.3.6.1.4.1.5454.1.80.6.6.16
.1.3.6.1.4.1.5454.1.80.6.7.1
.1.3.6.1.4.1.5454.1.80.6.7.2
.1.3.6.1.4.1.5454.1.80.6.7.3
.1.3.6.1.4.1.5454.1.80.6.7.4
.1.3.6.1.4.1.5454.1.80.6.8.1
.1.3.6.1.4.1.5454.1.80.6.8.2
.1.3.6.1.4.1.5454.1.80.6.8.3
.1.3.6.1.4.1.5454.1.80.6.8.4
.1.3.6.1.4.1.5454.1.80.6.8.5
.1.3.6.1.4.1.5454.1.80.6.8.6
.1.3.6.1.4.1.5454.1.80.6.8.7
.1.3.6.1.4.1.5454.1.80.6.8.8
.1.3.6.1.4.1.5454.1.80.6.9.1
.1.3.6.1.4.1.5454.1.80.6.9.2
.1.3.6.1.4.1.5454.1.80.6.10.1
.1.3.6.1.4.1.5454.1.80.6.10.2
.1.3.6.1.4.1.5454.1.80.6.11
.1.3.6.1.4.1.5454.1.80.6.12.1
.1.3.6.1.4.1.5454.1.80.6.12.2
.1.3.6.1.4.1.5454.1.80.6.12.3
.1.3.6.1.4.1.5454.1.80.6.12.4
.1.3.6.1.4.1.5454.1.80.6.12.5
.1.3.6.1.4.1.5454.1.80.6.12.6

trapACMRxProfileChange
trapIDUTempMinThreshold
trapIDUTempMaxThreshold
trapODUTempMinThreshold
trapODUTempMaxThreshold
trapMSEMinThreshold
trapMSEMaxThreshold
trapBERMinThreshold
trapBERMaxThreshold
trapFERMinThreshold
trapFERMaxThreshold
trapRSSIMinThreshold
trapRSSIMaxThreshold
trapInPortUtilMinThreshold
trapInPortUtilMaxThreshold
trapOutPortUtilMinThreshold
trapOutPortUtilMaxThreshold
trapVoltage1.25Failure
trapVoltage2.5Failure
trapVoltage3.3Failure
trapVoltage5Failure
trapTDM1StatusUpdate
trapTDM2StatusUpdate
trapTDM3StatusUpdate
trapTDM4StatusUpdate
trapTDM5StatusUpdate
trapTDM6StatusUpdate
trapTDM7StatusUpdate
trapTDM8StatusUpdate
trapManualSwitchover
trapHWSwitchover
trapRedundancyCableRemoved
trapRedundancyCableReconnected
trapLostODUCommunication
trapUtypeActiveElected
trapUtypeStandbyElected
trapActiveDetected
trapStandbyDetected
trapActiveDown
trapStandbyDown

RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

.1.3.6.1.4.1.5454.1.80.6.13

trapSynchronization

RO

TrangoSystems,Inc.

Access
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

Range Limit
N/A
N/A

Default Value
N/A
N/A

N/A
N/A
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(NORMAL), 1(LOCKED)
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
0(QPSK),
1(16Q),2(32Q),3(64Q),4(128Q)
, 5(256Q) for non-256Q,
0(QPSK), 1(16Q),2(64Q),
3(256Q) for 256Q
Current IDU Temp
Current IDU Temp
Current ODU Temp
Current ODU Temp
Current MSE value
Current MSE value
Current BER value
Current BER value
Current FER value
Current FER value
Current RSSI value
Current RSSI value
Current In port untilization
Current In port untilization
Current Out port untilization
Current Out port untilization
1(Failed)
1(Failed)
1(Failed)
1(Failed)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
0(OFF), 1(ON)
1(Active), 2(Standby)
1(Active), 2(Standby)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0(Not Synchronized),
1(Synchronized)

N/A
N/A
N/A
N/A
N/A
N/A
N/A

GigaPlusUserManualRev1.3

N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

202

AppendixEPartNumbers
GigaPlusHPODUSubbands/TuningRanges

Outdoor Unit
Part Numbers

Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)

Description

HP ODUs, 6 GHZ
HP2-06-0160-1A
HP2-06-0160-1B
HP2-06-0160-2A
HP2-06-0160-2B
HP2-06-0160-3A
HP2-06-0160-3B
HP2-06-0160-4A
HP2-06-0160-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,

ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,
ANSI/ETSI TR160,

1A
1B
2A
2B
3A
3B
4A
4B

- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band

6,540
6,700
6,580
6,740
6,620
6,780
6,660
6,820

6,600
6,760
6,640
6,800
6,680
6,840
6,710
6,870

60
60
60
60
60
60
50
50

56
56
56
56
56
56
50
50

HP2-06-0170-1A
HP2-06-0170-1B
HP2-06-0170-2A
HP2-06-0170-2B
HP2-06-0170-3A
HP2-06-0170-3B
HP2-06-0170-4A
HP2-06-0170-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,

ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,
ANSI/ETSI TR170,

1A
1B
2A
2B
3A
3B
4A
4B

- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band

6,540
6,710
6,580
6,750
6,620
6,790
6,660
6,830

6,590
6,760
6,630
6,800
6,670
6,840
6,700
6,870

50
50
50
50
50
50
40
40

50
50
50
50
50
50
40
40

HP-06-0240-1A
HP-06-0240-1B
HP-06-0240-2A
HP-06-0240-2B
HP-06-0240-3A
HP-06-0240-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

5,925
6,175
6,000
6,250
6,075
6,325

6,025
6,275
6,100
6,350
6,175
6,425

100
100
100
100
100
100

56
56
56
56
56
56

HP2-06-0252-1A
HP2-06-0252-1B
HP2-06-0252-2A
HP2-06-0252-2B
HP2-06-0252-3A
HP2-06-0252-3B
HP2-06-0252-4A
HP2-06-0252-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,

5,915.55
6,167.59
5,974.85
6,226.89
6,034.15
6,286.19
6,093.45
6,345.49

5,989.68
6,241.72
6,048.98
6,301.02
6,108.28
6,360.32
6,167.58
6,419.62

74
74
74
74
74
74
74
74

56
56
56
56
56
56
56
56

HP-06-0252-1A
HP-06-0252-1B
HP-06-0252-2A
HP-06-0252-2B
HP-06-0252-3A
HP-06-0252-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

5,925
6,175
6,000
6,250
6,075
6,325

6,025
6,275
6,100
6,350
6,175
6,425

100
100
100
100
100
100

56
56
56
56
56
56

HP2-06-0300-1A
HP2-06-0300-1B
HP2-06-0300-2A
HP2-06-0300-2B
HP2-06-0300-3A
HP2-06-0300-3B
HP2-06-0300-4A
HP2-06-0300-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,

5,850
6,150
5,918
6,218
5,986
6,286
6,054
6,354

5,946
6,246
6,014
6,314
6,082
6,382
6,150
6,450

96
96
96
96
96
96
96
96

56
56
56
56
56
56
56
56

TrangoSystems,Inc.

6Ghz,ETSI TR240, 1A
6Ghz, ETSI TR240, 1B
6Ghz, ETSI TR240, 2A
6Ghz, ETSI TR240, 2B
6Ghz, ETSI TR240, 3A
6Ghz, ETSI TR240, 3B

6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,

- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band

ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,

ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ANSI/ETSI TR252,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,
ETSI TR300,

1A
1B
2A
2B
3A
3B
4A
4B

1A
1B
2A
2B
3A
3B
4A
4B

1A
1B
2A
2B
3A
3B

- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band

- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band

- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band
- Low Band

GigaPlusUserManualRev1.3

203

Outdoor Unit
Part Numbers

Description

HP2-06-0340-1A
HP2-06-0340-1B
HP2-06-0340-2A
HP2-06-0340-2B
HP2-06-0340-3A
HP2-06-0340-3B
HP2-06-0340-4A
HP2-06-0340-4B
HP2-06-0340-5A
HP2-06-0340-5B
HP2-06-0340-6A
HP2-06-0340-6B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,

HP-06-0340-1A
HP-06-0340-1B
HP-06-0340-2A
HP-06-0340-2B
HP-06-0340-3A
HP-06-0340-3B
HP-06-0340-4A
HP-06-0340-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

HP2-06-0350-1A
HP2-06-0350-1B
HP2-06-0350-2A
HP2-06-0350-2B
HP2-06-0350-3A
HP2-06-0350-3B
HP2-06-0350-4A
HP2-06-0350-4B
HP2-06-0350-5A
HP2-06-0350-5B
HP2-06-0350-6A
HP2-06-0350-6B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,
HP2 6Ghz,

TrangoSystems,Inc.

6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,
6Ghz,

ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,

ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,
ETSI TR340,

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B

1A
1B
2A
2B
3A
3B
4A
4B

ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,
ETSI TR350,

- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band

- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B

- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band
- High Band

Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)
6,425
6,765
6,481
6,821
6,536
6,876
6,591
6,931
6,646
6,986
6,701
7,041

6,509
6,849
6,564
6,904
6,619
6,959
6,674
7,014
6,729
7,069
6,785
7,125

84
84
83
83
83
83
83
83
83
83
84
84

56
56
56
56
56
56
56
56
56
56
56
56

6,430
6,770
6,520
6,860
6,600
6,940
6,670
7,010

6,540
6,880
6,630
6,970
6,710
7,050
6,780
7,120

110
110
110
110
110
110
110
110

56
56
56
56
56
56
56
56

6,425
6,775
6,481
6,831
6,536
6,886
6,591
6,941
6,646
6,996
6,701
7,051

6,499
6,849
6,554
6,904
6,609
6,959
6,664
7,014
6,719
7,069
6,775
7,125

74
74
73
73
73
73
73
73
73
73
74
74

56
56
56
56
56
56
56
56
56
56
56
56

GigaPlusUserManualRev1.3

204

Outdoor Unit
Part Numbers

Description

Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)

HP ODUs, 7 GHZ
HP2-07-0154-1A
HP2-07-0154-1B
HP2-07-0154-2A
HP2-07-0154-2B
HP2-07-0154-3A
HP2-07-0154-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,

HP-07-0154-1A
HP-07-0154-1B
HP-07-0154-2A
HP-07-0154-2B
HP-07-0154-3A
HP-07-0154-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

HP2-07-0160-1A
HP2-07-0160-1B
HP2-07-0160-2A
HP2-07-0160-2B
HP2-07-0160-3A
HP2-07-0160-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,

HP-07-0160-1A
HP-07-0160-1B
HP-07-0160-2A
HP-07-0160-2B
HP-07-0160-3A
HP-07-0160-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

HP2-07-0161-1A
HP2-07-0161-1B
HP2-07-0161-2A
HP2-07-0161-2B
HP2-07-0161-3A
HP2-07-0161-3B
HP2-07-0161-4A
HP2-07-0161-4B
HP2-07-0161-5A
HP2-07-0161-5B
HP2-07-0161-6A
HP2-07-0161-6B
HP2-07-0161-7A
HP2-07-0161-7B
HP2-07-0161-8A
HP2-07-0161-8B
HP2-07-0161-9A
HP2-07-0161-9B
HP2-07-0161-10A
HP2-07-0161-10B
HP2-07-0161-21A
HP2-07-0161-21B
HP2-07-0161-22A
HP2-07-0161-22B
HP2-07-0161-23A
HP2-07-0161-23B
HP2-07-0161-24A
HP2-07-0161-24B
HP2-07-0161-25A
HP2-07-0161-25B
HP2-07-0161-26A
HP2-07-0161-26B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,

TrangoSystems,Inc.

7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,

7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,

ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,

ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,
ETSI TR154,

1A
1B
2A
2B
3A
3B

ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,

ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,
ETSI TR160,

1A
1B
2A
2B
3A
3B

1A
1B
2A
2B
3A
3B

1A
1B
2A
2B
3A
3B

ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
21A
21B
22A
22B
23A
23B
24A
24B
25A
25B
26A
26B

7,428
7,582
7,470
7,624
7,512
7,666

7,484
7,638
7,526
7,680
7,568
7,722

56
56
56
56
56
56

56
56
56
56
56
56

7,428
7,582
7,470
7,624
7,512
7,666

7,484
7,638
7,526
7,680
7,568
7,722

56
56
56
56
56
56

56
56
56
56
56
56

7,434
7,594
7,479
7,639
7,526
7,686

7,497
7,657
7,542
7,702
7,589
7,749

63
63
63
63
63
63

56
56
56
56
56
56

7,433.5
7,593.5
7,478.5
7,638.5
7,526.0
7,686.0

7,496.5
7,656.5
7,541.5
7,701.5
7,589.0
7,749.0

63
63
63
63
63
63

56
56
56
56
56
56

7,114
7,275
7,149
7,310
7,184
7,345
7,219
7,380
7,239
7,400
7,274
7,435
7,309
7,470
7,344
7,505
7,414
7,575
7,449
7,610
7,484
7,645
7,519
7,680
7,539
7,700
7,574
7,735
7,609
7,770
7,644
7,805

7,177
7,338
7,212
7,373
7,247
7,408
7,282
7,443
7,302
7,463
7,337
7,498
7,372
7,533
7,407
7,568
7,477
7,638
7,512
7,673
7,547
7,708
7,582
7,743
7,602
7,763
7,637
7,798
7,672
7,833
7,707
7,868

63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63

56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56

GigaPlusUserManualRev1.3

205

Outdoor Unit
Part Numbers

Description

HP-07-0161-1A
HP-07-0161-1B
HP-07-0161-2A
HP-07-0161-2B
HP-07-0161-3A
HP-07-0161-3B
HP-07-0161-4A
HP-07-0161-4B
HP-07-0161-5A
HP-07-0161-5B
HP-07-0161-6A
HP-07-0161-6B
HP-07-0161-7A
HP-07-0161-7B
HP-07-0161-8A
HP-07-0161-8B
HP-07-0161-9A
HP-07-0161-9B
HP-07-0161-10A
HP-07-0161-10B
HP-07-0161-21A
HP-07-0161-21B
HP-07-0161-22A
HP-07-0161-22B
HP-07-0161-23A
HP-07-0161-23B
HP-07-0161-24A
HP-07-0161-24B
HP-07-0161-25A
HP-07-0161-25B
HP-07-0161-26A
HP-07-0161-26B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP

HP2-07-0168-1A
HP2-07-0168-1B
HP2-07-0168-2A
HP2-07-0168-2B
HP2-07-0168-3A
HP2-07-0168-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,

HP-07-0168-1A
HP-07-0168-1B
HP-07-0168-2A
HP-07-0168-2B
HP-07-0168-3A
HP-07-0168-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

TrangoSystems,Inc.

7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,

7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,

ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,
ETSI TR161,

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
21A
21B
22A
22B
23A
23B
24A
24B
25A
25B
26A
26B

ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,

ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,
ETSI TR168,

1A
1B
2A
2B
3A
3B

1A
1B
2A
2B
3A
3B

Max
TX Freq TX Freq Diplexer Chan
Size
Range
Max*
Min*
(MHz) (MHz)
(MHz)
(MHz)
7,114
7,275
7,149
7,310
7,184
7,345
7,219
7,380
7,239
7,400
7,274
7,435
7,309
7,470
7,344
7,505
7,414
7,575
7,449
7,610
7,484
7,645
7,519
7,680
7,539
7,700
7,574
7,735
7,609
7,770
7,644
7,805

7,177
7,338
7,212
7,373
7,247
7,408
7,282
7,443
7,302
7,463
7,337
7,498
7,372
7,533
7,407
7,568
7,477
7,638
7,512
7,673
7,547
7,708
7,582
7,743
7,602
7,763
7,637
7,798
7,672
7,833
7,707
7,868

63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63

56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56
56

7,443
7,611
7,485
7,653
7,527
7,695

7,499
7,667
7,541
7,709
7,583
7,751

56
56
56
56
56
56

56
56
56
56
56
56

7,443
7,611
7,485
7,653
7,527
7,695

7,499
7,667
7,541
7,709
7,583
7,751

56
56
56
56
56
56

56
56
56
56
56
56

GigaPlusUserManualRev1.3

206

Outdoor Unit
Part Numbers

Description

HP2-07-0196-1A
HP2-07-0196-1B
HP2-07-0196-2A
HP2-07-0196-2B
HP2-07-0196-3A
HP2-07-0196-3B
HP2-07-0196-4A
HP2-07-0196-4B
HP2-07-0196-5A
HP2-07-0196-5B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,

HP-07-0196-1A
HP-07-0196-1B
HP-07-0196-2A
HP-07-0196-2B
HP-07-0196-3A
HP-07-0196-3B
HP-07-0196-4A
HP-07-0196-4B
HP-07-0196-5A
HP-07-0196-5B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP
HP
HP

HP2-07-0245-1A
HP2-07-0245-1B
HP2-07-0245-2A
HP2-07-0245-2B
HP2-07-0245-3A
HP2-07-0245-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,
HP2 7Ghz,

HP-07-0245-1A
HP-07-0245-1B
HP-07-0245-2A
HP-07-0245-2B
HP-07-0245-3A
HP-07-0245-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

TrangoSystems,Inc.

7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,

7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,
7Ghz,

ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,

ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,
ETSI TR196,

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B

ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,

ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,
ETSI TR245,

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B

1A
1B
2A
2B
3A
3B

1A
1B
2A
2B
3A
3B

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
7,093
7,289
7,121
7,317
7,149
7,345
7,177
7,373
7,205
7,401

7,149
7,345
7,177
7,373
7,205
7,401
7,233
7,429
7,261
7,457

56
56
56
56
56
56
56
56
56
56

56
56
56
56
56
56
56
56
56
56

7,093
7,289
7,121
7,317
7,149
7,345
7,177
7,373
7,205
7,401

7,149
7,345
7,177
7,373
7,205
7,401
7,233
7,429
7,261
7,457

56
56
56
56
56
56
56
56
56
56

56
56
56
56
56
56
56
56
56
56

7,400
7,645
7,484
7,729
7,568
7,813

7,484
7,729
7,568
7,813
7,652
7,897

84
84
84
84
84
84

56
56
56
56
56
56

7,400
7,645
7,484
7,729
7,568
7,813

7,484
7,729
7,568
7,813
7,652
7,897

84
84
84
84
84
84

56
56
56
56
56
56

GigaPlusUserManualRev1.3

207

Outdoor Unit
Part Numbers

Description

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)

HP ODUs,- 8 GHZ
HP2-08-0119-1A
HP2-08-0119-1B
HP2-08-0119-2A
HP2-08-0119-2B
HP2-08-0119-3A
HP2-08-0119-3B
HP2-08-0119-4A
HP2-08-0119-4B
HP2-08-0119-5A
HP2-08-0119-5B
HP2-08-0119-6A
HP2-08-0119-6B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,

HP-08-0119-1A
HP-08-0119-1B
HP-08-0119-2A
HP-08-0119-2B
HP-08-0119-3A
HP-08-0119-3B
HP-08-0119-4A
HP-08-0119-4B
HP-08-0119-5A
HP-08-0119-5B
HP-08-0119-6A
HP-08-0119-6B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP

8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,

ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,

HP-08-0151-1A
HP-08-0151-1B
HP-08-0151-2A
HP-08-0151-2B
HP-08-0151-3A
HP-08-0151-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,

ETSI TR151,
ETSI TR151,
ETSI TR151,
ETSI TR151,
ETSI TR151,
ETSI TR151,

HP2-08-0208-1A
HP2-08-0208-1B
HP2-08-0208-2A
HP2-08-0208-2B
HP2-08-0208-3A
HP2-08-0208-3B
HP2-08-0208-4A
HP2-08-0208-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,

HP-08-0208-1A
HP-08-0208-1B
HP-08-0208-2A
HP-08-0208-2B
HP-08-0208-3A
HP-08-0208-3B
HP-08-0208-4A
HP-08-0208-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

TrangoSystems,Inc.

8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,
8Ghz,

ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,
ETSI TR119,

8,279
8,398
8,293
8,412
8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468

8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468
8,363
8,482
8,377
8,496

28
28
28
28
28
28
28
28
28
28
28
28

28
28
28
28
28
28
28
28
28
28
28
28

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B

8,279
8,398
8,293
8,412
8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468

8,307
8,426
8,321
8,440
8,335
8,454
8,349
8,468
8,363
8,482
8,377
8,496

28
28
28
28
28
28
28
28
28
28
28
28

28
28
28
28
28
28
28
28
28
28
28
28

1A
1B
2A
2B
3A
3B

8,203
8,355
8,240
8,392
8,277
8,429

8,271
8,423
8,308
8,460
8,345
8,497

68
68
68
68
68
68

56
56
56
56
56
56

8,043
8,251
8,099
8,307
8,155
8,363
8,211
8,419

8,113
8,321
8,169
8,377
8,225
8,433
8,281
8,489

70
70
70
70
70
70
70
70

56
56
56
56
56
56
56
56

8,043
8,251
8,099
8,307
8,155
8,363
8,211
8,419

8,113
8,321
8,169
8,377
8,225
8,433
8,281
8,489

70
70
70
70
70
70
70
70

56
56
56
56
56
56
56
56

ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,

ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,
ETSI TR208,

1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B

1A
1B
2A
2B
3A
3B
4A
4B

1A
1B
2A
2B
3A
3B
4A
4B

GigaPlusUserManualRev1.3

208

Outdoor Unit
Part Numbers

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)

Description

HP2-08-0266-1A
HP2-08-0266-1B
HP2-08-0266-2A
HP2-08-0266-2B

ODU,
ODU,
ODU,
ODU,

HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,

HP-08-0266-1A
HP-08-0266-1B
HP-08-0266-2A
HP-08-0266-2B

ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP

HP2-08-0311-1A
HP2-08-0311-1B
HP2-08-0311-2A
HP2-08-0311-2B

ODU,
ODU,
ODU,
ODU,

HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,
HP2 8Ghz,

HP-08-0311-2A
HP-08-0311-2B
HP-08-0311-3A
HP-08-0311-3B

ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP

8Ghz,
8Ghz,
8Ghz,
8Ghz,

8Ghz,
8Ghz,
8Ghz,
8Ghz,

ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,

ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,

1A
1B
2A
2B

ETSI TR311,
ETSI TR311,
ETSI TR311,
ETSI TR311,

ETSI TR311,
ETSI TR311,
ETSI TR311,
ETSI TR311,

1A
1B
2A
2B

1A
1B
2A
2B

2A
2B
3A
3B

7,905
8,171
8,017
8,283

8,024
8,290
8,136
8,402

119
119
119
119

56
56
56
56

7,905
8,171
8,017
8,283

8,024
8,290
8,136
8,402

119
119
119
119

56
56
56
56

7,731
8,042
7,835
8,146

7,867
8,178
7,971
8,282

136
136
136
136

56
56
56
56

7,835
8,146
7,717
8,028

7,971
8,282
7,867
8,178

136
136
150
150

56
56
56
56

10,150
10,500

10,300
10,650

150
150

56
56

10,700
11,200
10,855
11,355
11,010
11,510

10,890
11,390
11,045
11,545
11,200
11,700

190
190
190
190
190
190

56
56
56
56
56
56

10,700
11,200
10,855
11,355
11,010
11,510

10,890
11,390
11,045
11,545
11,200
11,700

190
190
190
190
190
190

56
56
56
56
56
56

10,675
11,205
10,795
11,325
10,915
11,445
11,035
11,565

10,855
11,385
10,975
11,505
11,135
11,665
11,215
11,745

180
180
180
180
220
220
180
180

56
56
56
56
56
56
56
56

10,675
11,205
10,795
11,325
10,915
11,445
11,035
11,565

10,855
11,385
10,975
11,505
11,135
11,665
11,215
11,745

180
180
180
180
220
220
180
180

56
56
56
56
56
56
56
56

HP ODUs,- 10 GHZ
HP2-10-0350-1A
HP2-10-0350-1B

ODU, HP2 10Ghz, ETSI TR350, 1A


ODU, HP2 10Ghz, ETSI TR350, 1B

HP ODUs, 11 GHZ
HP2-11-0490-5A
HP2-11-0490-5B
HP2-11-0490-6A
HP2-11-0490-6B
HP2-11-0490-7A
HP2-11-0490-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,

HP-11-0490-5A
HP-11-0490-5B
HP-11-0490-6A
HP-11-0490-6B
HP-11-0490-7A
HP-11-0490-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

HP2-11-0530-1A
HP2-11-0530-1B
HP2-11-0530-2A
HP2-11-0530-2B
HP2-11-0530-3A
HP2-11-0530-3B
HP2-11-0530-4A
HP2-11-0530-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,
HP2 11Ghz,

HP-11-0530-1A
HP-11-0530-1B
HP-11-0530-2A
HP-11-0530-2B
HP-11-0530-3A
HP-11-0530-3B
HP-11-0530-4A
HP-11-0530-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

TrangoSystems,Inc.

11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,

11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,
11Ghz,

ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,

ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ANSI/ETSI TR490/500,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,

ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,
ETSI TR530,

1A
1B
2A
2B
3A
3B
4A
4B

1A
1B
2A
2B
3A
3B
4A
4B

5A
5B
6A
6B
7A
7B

5A
5B
6A
6B
7A
7B

GigaPlusUserManualRev1.3

209

Outdoor Unit
Part Numbers

Description

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)

HP ODUs, 13 GHZ
HP2-13-0266-1A
HP2-13-0266-1B
HP2-13-0266-2A
HP2-13-0266-2B
HP2-13-0266-3A
HP2-13-0266-3B
HP2-13-0266-4A
HP2-13-0266-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,
HP2 13Ghz,

HP-13-0266-1A
HP-13-0266-1B
HP-13-0266-2A
HP-13-0266-2B
HP-13-0266-3A
HP-13-0266-3B
HP-13-0266-4A
HP-13-0266-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,
13Ghz,

ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,

ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,
ETSI TR266,

1A
1B
2A
2B
3A
3B
4A
4B

1A
1B
2A
2B
3A
3B
4A
4B

12,751
13,017
12,807
13,073
12,863
13,129
12,919
13,185

12,814
13,080
12,870
13,136
12,926
13,192
12,982
13,248

63
63
63
63
63
63
63
63

56
56
56
56
56
56
56
56

12,751
13,017
12,807
13,073
12,863
13,129
12,919
13,185

12,814
13,080
12,870
13,136
12,926
13,192
12,982
13,248

63
63
63
63
63
63
63
63

56
56
56
56
56
56
56
56

14,627
14,942
14,725
15,040
14,823
15,138

14,732
15,047
14,844
15,159
14,928
15,243

105
105
119
119
105
105

56
56
56
56
56
56

14,627
14,942
14,725
15,040
14,823
15,138

14,746
15,061
14,844
15,159
14,942
15,257

119
119
119
119
119
119

56
56
56
56
56
56

14,501
14,921
14,606
15,026
14,718
15,138
14,816
15,236

14,613
15,033
14,725
15,145
14,837
15,257
14,928
15,348

112
112
119
119
119
119
112
112

56
56
56
56
56
56
56
56

14,501
14,921
14,606
15,026
14,718
15,138
14,816
15,236

14,613
15,033
14,725
15,145
14,837
15,257
14,928
15,348

112
112
119
119
119
119
112
112

56
56
56
56
56
56
56
56

HP ODUs, 15 GHZ
HP2-15-0315-1A
HP2-15-0315-1B
HP2-15-0315-2A
HP2-15-0315-2B
HP2-15-0315-3A
HP2-15-0315-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,

HP-15-0315-1A
HP-15-0315-1B
HP-15-0315-2A
HP-15-0315-2B
HP-15-0315-3A
HP-15-0315-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

HP2-15-0420-4A
HP2-15-0420-4B
HP2-15-0420-5A
HP2-15-0420-5B
HP2-15-0420-6A
HP2-15-0420-6B
HP2-15-0420-7A
HP2-15-0420-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,

HP-15-0420-4A
HP-15-0420-4B
HP-15-0420-5A
HP-15-0420-5B
HP-15-0420-6A
HP-15-0420-6B
HP-15-0420-7A
HP-15-0420-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

TrangoSystems,Inc.

15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,

15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,

ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,

ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,
ETSI TR315,

1A
1B
2A
2B
3A
3B

ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,

ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,
ETSI TR420,

1A
1B
2A
2B
3A
3B

4A
4B
5A
5B
6A
6B
7A
7B

4A
4B
5A
5B
6A
6B
7A
7B

GigaPlusUserManualRev1.3

210

Outdoor Unit
Part Numbers

Description

HP2-15-0490-4A
HP2-15-0490-4B
HP2-15-0490-5A
HP2-15-0490-5B
HP2-15-0490-6A
HP2-15-0490-6B
HP2-15-0490-7A
HP2-15-0490-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,

HP-15-0490-4A
HP-15-0490-4B
HP-15-0490-5A
HP-15-0490-5B
HP-15-0490-6A
HP-15-0490-6B
HP-15-0490-7A
HP-15-0490-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

HP2-15-0475-1A
HP2-15-0475-1B
HP2-15-0475-2A
HP2-15-0475-2B
HP2-15-0475-3A
HP2-15-0475-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,

HP-15-0475-1A
HP-15-0475-1B
HP-15-0475-2A
HP-15-0475-2B
HP-15-0475-3A
HP-15-0475-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

HP2-15-0640-1A
HP2-15-0640-1B
HP2-15-0640-2A
HP2-15-0640-2B

ODU,
ODU,
ODU,
ODU,

HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,

HP-15-0640-1A
HP-15-0640-1B
HP-15-0640-2A
HP-15-0640-2B

ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP

HP2-15-0644-1A
HP2-15-0644-1B
HP2-15-0644-2A
HP2-15-0644-2B
HP2-15-0644-3A
HP2-15-0644-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,
HP2 15Ghz,

HP-15-0644-1A
HP-15-0644-1B
HP-15-0644-2A
HP-15-0644-2B
HP-15-0644-3A
HP-15-0644-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

TrangoSystems,Inc.

15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,

15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,

15Ghz,
15Ghz,
15Ghz,
15Ghz,

15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,
15Ghz,

ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,

ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,
ETSI TR490,

4A
4B
5A
5B
6A
6B
7A
7B

ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,

ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,
ETSI TR475,

1A
1B
2A
2B

1A
1B
2A
2B

ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,

ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,
ETSI TR644,

1A
1B
2A
2B
3A
3B

1A
1B
2A
2B
3A
3B

ETSI TR640,
ETSI TR640,
ETSI TR640,
ETSI TR640,

ETSI TR640,
ETSI TR640,
ETSI TR640,
ETSI TR640,

4A
4B
5A
5B
6A
6B
7A
7B

1A
1B
2A
2B
3A
3B

1A
1B
2A
2B
3A
3B

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)
14,403
14,893
14,515
15,005
14,627
15,117
14,739
15,229

14,522
15,012
14,634
15,124
14,746
15,236
14,858
15,348

119
119
119
119
119
119
119
119

56
56
56
56
56
56
56
56

14,403
14,893
14,515
15,005
14,627
15,117
14,739
15,229

14,522
15,012
14,634
15,124
14,746
15,236
14,858
15,348

119
119
119
119
119
119
119
119

56
56
56
56
56
56
56
56

14,500
14,975
14,660
15,135
14,715
15,190

14,668
15,143
14,828
15,303
14,883
15,358

168
168
168
168
168
168

56
56
56
56
56
56

14,500
14,975
14,660
15,135
14,783
15,258

14,668
15,143
14,828
15,303
14,883
15,358

168
168
168
168
100
100

56
56
56
56
56
56

14,500
15,140
14,605
15,245

14,610
15,250
14,715
15,355

110
110
110
110

56
56
56
56

14,500
15,140
14,605
15,245

14,610
15,250
14,715
15,355

110
110
110
110

56
56
56
56

14,400
15,044
14,498
15,142
14,596
15,240

14,512
15,156
14,610
15,254
14,708
15,352

112
112
112
112
112
112

56
56
56
56
56
56

14,400
15,044
14,498
15,142
14,596
15,240

14,512
15,156
14,610
15,254
14,708
15,352

112
112
112
112
112
112

56
56
56
56
56
56

GigaPlusUserManualRev1.3

211

Outdoor Unit
Part Numbers

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)

Description

HP-15-0728-1A
HP-15-0728-1B
HP-15-0728-2A
HP-15-0728-2B

ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP

15Ghz,
15Ghz,
15Ghz,
15Ghz,

ETSI TR728,
ETSI TR728,
ETSI TR728,
ETSI TR728,

1A
1B
2A
2B

HP2-15-0728-1A
HP2-15-0728-1B

ODU, HP2 15Ghz, ETSI TR728, 1A


ODU, HP2 15Ghz, ETSI TR728, 1B

14,500
15,228
14,500
15,228

14,615
15,343
14,625
15,353

115
115
125
125

56
56
56
56

14,500
15,228

14,615
15,343

115
115

56
56

17,685
18,695
17,930
18,940
18,180
19,190
18,400
19,410

17,985
18,995
18,230
19,240
18,480
19,490
18,700
19,710

300
300
300
300
300
300
300
300

56
56
56
56
56
56
56
56

17,685
18,695
17,930
18,940
18,180
19,190
18,400
19,410

17,985
18,995
18,230
19,240
18,480
19,490
18,700
19,710

300
300
300
300
300
300
300
300

56
56
56
56
56
56
56
56

17,700
18,805
17,975
19,080
18,235
19,340

18,060
19,165
18,335
19,440
18,595
19,700

360
360
360
360
360
360

56
56
56
56
56
56

HP ODUs, 18 GHZ
HP2-18-1010-1A
HP2-18-1010-1B
HP2-18-1010-2A
HP2-18-1010-2B
HP2-18-1010-3A
HP2-18-1010-3B
HP2-18-1010-4A
HP2-18-1010-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,
HP2 18Ghz,

HP-18-1010-1A
HP-18-1010-1B
HP-18-1010-2A
HP-18-1010-2B
HP-18-1010-3A
HP-18-1010-3B
HP-18-1010-4A
HP-18-1010-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,

ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,

HP-18-1092-1A
HP-18-1092-1B
HP-18-1092-2A
HP-18-1092-2B
HP-18-1092-3A
HP-18-1092-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,
18Ghz,

ETSI TR1092,
ETSI TR1092,
ETSI TR1092,
ETSI TR1092,
ETSI TR1092,
ETSI TR1092,

HP2-18-1560-3A
HP2-18-1560-3B

ODU, HP2 18Ghz, ANSI TR1560, 3A


ODU, HP2 18Ghz, ANSI TR1560, 3B

17,700
19,260

18,140
19,700

440
440

56
56

HP-18-1560-3A
HP-18-1560-3B

ODU, HP 18Ghz, ANSI TR1560, 3A


ODU, HP 18Ghz, ANSI TR1560, 3B

17,700
19,260

18,140
19,700

440
440

56
56

TrangoSystems,Inc.

ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,
ETSI TR1010/1008,

1A
1B
2A
2B
3A
3B

1A
1B
2A
2B
3A
3B
4A
4B

1A
1B
2A
2B
3A
3B
4A
4B

GigaPlusUserManualRev1.3

212

Outdoor Unit
Part Numbers

Description

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)

HP ODUs, 23 GHZ
HP2-23-1008-1A
HP2-23-1008-1B
HP2-23-1008-2A
HP2-23-1008-2B

ODU,
ODU,
ODU,
ODU,

HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,

HP-23-1008-1A
HP-23-1008-1B
HP-23-1008-2A
HP-23-1008-2B

ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP

HP2-23-1200-5A
HP2-23-1200-5B
HP2-23-1200-6A
HP2-23-1200-6B
HP2-23-1200-7A
HP2-23-1200-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,

HP-23-1200-5A
HP-23-1200-5B
HP-23-1200-6A
HP-23-1200-6B
HP-23-1200-7A
HP-23-1200-7B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

HP2-23-1232-1A
HP2-23-1232-1B
HP2-23-1232-2A
HP2-23-1232-2B
HP2-23-1232-3A
HP2-23-1232-3B
HP2-23-1232-4A
HP2-23-1232-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,
HP2 23Ghz,

HP-23-1232-1A
HP-23-1232-1B
HP-23-1232-2A
HP-23-1232-2B
HP-23-1232-3A
HP-23-1232-3B
HP-23-1232-4A
HP-23-1232-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

TrangoSystems,Inc.

23Ghz,
23Ghz,
23Ghz,
23Ghz,

23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,

23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,
23Ghz,

ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,

ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,

1A
1B
2A
2B

ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,

ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,
ANSI TR1200,

5A
5B
6A
6B
7A
7B

5A
5B
6A
6B
7A
7B

ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,

ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,
ETSI TR1232,

1A
1B
2A
2B

1A
1B
2A
2B
3A
3B
4A
4B

1A
1B
2A
2B
3A
3B
4A
4B

22,000
23,008
22,286
23,294

22,314
23,322
22,600
23,608

314
314
314
314

56
56
56
56

21,994
23,002
22,274
23,282

22,330
23,338
22,610
23,618

336
336
336
336

56
56
56
56

21,200
22,400
21,600
22,800
22,000
23,200

21,600
22,800
22,000
23,200
22,400
23,600

400
400
400
400
400
400

56
56
56
56
56
56

21,200
22,400
21,600
22,800
22,000
23,200

21,600
22,800
22,000
23,200
22,400
23,600

400
400
400
400
400
400

56
56
56
56
56
56

21,200
22,432
21,472
22,704
21,779
23,011
22,086
23,318

21,500
22,732
21,786
23,018
22,093
23,325
22,386
23,618

300
300
314
314
314
314
300
300

56
56
56
56
56
56
56
56

21,200
22,432
21,472
22,704
21,779
23,011
22,086
23,318

21,500
22,732
21,786
23,018
22,093
23,325
22,386
23,618

300
300
314
314
314
314
300
300

56
56
56
56
56
56
56
56

GigaPlusUserManualRev1.3

213

Outdoor Unit
Part Numbers

Max
TX Freq TX Freq Diplexer Chan
Min*
Max*
Range
Size
(MHz)
(MHz)
(MHz) (MHz)

Description

HP ODUs, 26 GHZ
HP2-26-0800-1A
HP2-26-0800-1B

ODU, HP2 26Ghz, ETSI TR800, 1A


ODU, HP2 26Ghz, ETSI TR800, 1B

24,250
25,050

24,450
25,250

200
200

56
56

HP-26-0800-1A
HP-26-0800-1B

ODU, HP 26Ghz, ETSI TR800, 1A


ODU, HP 26Ghz, ETSI TR800, 1B

24,250
25,050

24,450
25,250

200
200

56
56

HP2-26-1008-1A
HP2-26-1008-1B
HP2-26-1008-2A
HP2-26-1008-2B
HP2-26-1008-3A
HP2-26-1008-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,
HP2 26Ghz,

24,549
25,557
24,843
25,851
25,123
26,131

24,871
25,879
25,151
26,159
25,445
26,453

322
322
308
308
322
322

56
56
56
56
56
56

HP-26-1008-1A
HP-26-1008-1B
HP-26-1008-2A
HP-26-1008-2B
HP-26-1008-3A
HP-26-1008-3B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP

1A
1B
2A
2B
3A
3B

24,549
25,557
24,829
25,837
25,109
26,117

24,885
25,893
25,165
26,173
25,445
26,453

336
336
336
336
336
336

56
56
56
56
56
56

1A
1B
2A
2B

27,520
28,528
27,968
28,976

28,025
29,033
28,473
29,481

505
505
505
505

56
56
56
56

31,815
32,627
32,179
32,991

32,207
33,019
32,571
33,383

392
392
392
392

56
56
56
56

38,595
39,295
38,795
39,495
38,995
39,695
39,195
39,895

38,805
39,505
39,005
39,705
39,205
39,905
39,405
40,105

210
210
210
210
210
210
210
210

56
56
56
56
56
56
56
56

26Ghz,
26Ghz,
26Ghz,
26Ghz,
26Ghz,
26Ghz,

ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,

ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,

1A
1B
2A
2B
3A
3B

HP ODUs, 28 GHZ
HP-28-1008-1A
HP-28-1008-1B
HP-28-1008-2A
HP-28-1008-2B

ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP

28Ghz,
28Ghz,
28Ghz,
28Ghz,

ETSI TR1008,
ETSI TR1008,
ETSI TR1008,
ETSI TR1008,

HP ODUs, 32 GHZ
HP-32-0812-1A
HP-32-0812-1B
HP-32-0812-2A
HP-32-0812-2B

ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP

32Ghz,
32Ghz,
32Ghz,
32Ghz,

ETSI TR812,
ETSI TR812,
ETSI TR812,
ETSI TR812,

1A
1B
2A
2B

HP ODUs 38 GHZ
HP-38-0700-1A
HP-38-0700-1B
HP-38-0700-2A
HP-38-0700-2B
HP-38-0700-3A
HP-38-0700-3B
HP-38-0700-4A
HP-38-0700-4B

ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,
ODU,

HP
HP
HP
HP
HP
HP
HP
HP

38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,
38Ghz,

ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,
ANSI/ETSI TR700,

1A
1B
2A
2B
3A
3B
4A
4B

HP2-38-1260-1A

ODU, HP2 38Ghz ETSI TR1260, 1A

37,044

37,632

588

56

HP2-38-1260-1B

ODU, HP2 38Ghz ETSI TR1260, 1B

38,304

38,892

588

56

HP2-38-1260-2A

ODU, HP2 38Ghz ETSI TR1260, 2A

37,604

38,192

588

56

HP2-38-1260-2B

ODU, HP2 38Ghz ETSI TR1260, 2B

38,864

39,452

588

56

HP-38-1260-1A
HP-38-1260-1B
HP-38-1260-2A
HP-38-1260-2B

ODU,
ODU,
ODU,
ODU,

37,044
38,304
37,604
38,864

37,632
38,892
38,192
39,452

588
588
588
588

56
56
56
56

HP
HP
HP
HP

38Ghz,
38Ghz,
38Ghz,
38Ghz,

ANSI/ETSI TR1260,
ANSI/ETSI TR1260,
ANSI/ETSI TR1260,
ANSI/ETSI TR1260,

1A
1B
2A
2B

* Frequencies shown are NOT center frequencies, but rather the edge of the transmit band.
Center frequency limits are 1/2 the channel bandwidth away from these numbers.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

214

Accessories
TRANGO PtP MICROWAVE BAND SPECIFIC ACCESSORIES
Model

Antenna

3/3 dB Dir
Mnt Comb

1.9/6 dB Dir
Mnt Comb

Dir Mnt
Ortho
Comb

Remote Mount

Rem Mnt 3/3


dB Comb

Rem Mnt 1.9/6


dB Comb

HP ODUs - 6 GHZ
HP-06-0240-xx
AD6GL-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP
HP-06-0252-xx
AD6GL-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP
HP-06-0340-xx
AD6GU-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP
HP2-06-0160-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0170-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0252-xx
AD6GL-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0300-xx
AD6GL-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0340-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
HP2-06-0350-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2
Note: All -R3 Antennas require a Remote Mount for the ODU and Waveguide

HP-MNT-06-WR137
HP-MNT-06-WR137
HP-MNT-06-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137
HP2-MNT-6-WR137

SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R
SMC-06-3-HP-R

SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R

HP ODUs - 7 GHZ
HP-07-xxxx-xx
HP2-07-xxxx-xx

AD7G-xx-S2
AD7G-xx-S2

SMC-78-3-HP
SMC-78-3-HP

SMC-78-6-HP
SMC-78-6-HP

OMC-07-HP
OMC-07-HP

HP-MNT-78-WR112 SMC-78-3-HP-R
HP-MNT-78-WR112 SMC-78-3-HP-R

SMC-78-6-HP-R
SMC-78-6-HP-R

SMC-78-3-HP
SMC-78-3-HP

SMC-78-6-HP
SMC-78-6-HP

OMC-07-HP
OMC-07-HP

HP-MNT-78-WR112 SMC-78-3-HP-R
HP-MNT-78-WR112 SMC-78-3-HP-R

SMC-78-6-HP-R
SMC-78-6-HP-R

HP ODUs - 8 GHZ
HP-08-xxxx-xx
HP2-08-xxxx-xx

AD8G-xx-R2
AD8G-xx-R2

HP ODUs - 10 GHZ
HP2-10-xxxx-xx

AD10G-xx-S2

NA

NA

NA

NA

NA

NA

HP ODUs - 11 GHZ
HP-11-xxxx-xx
HP2-11-xxxx-xx

AD11G-xx-S2, -R2
AD11G-xx-S2, -R2

SMC-11-3-HP
SMC-11-3-HP

SMC-11-6-HP
SMC-11-6-HP

OMC-11-HP
OMC-11-HP

HP-MNT-11-WR75
HP-MNT-11-WR75

SMC-11-3-HP-R
SMC-11-3-HP-R

SMC-11-6-HP-R
SMC-11-6-HP-R

SMC-13-3-HP
SMC-13-3-HP

SMC-13-6-HP
SMC-13-6-HP

OMC-13-HP
OMC-13-HP

HP-MNT-13-WR75
HP-MNT-13-WR75

SMC-13-3-HP-R
SMC-13-3-HP-R

SMC-13-6-HP-R
SMC-13-6-HP-R

SMC-15-3-HP
SMC-15-3-HP

SMC-15-6-HP
SMC-15-6-HP

OMC-15-HP
OMC-15-HP

HP-MNT-15-WR62
HP-MNT-15-WR62

SMC-15-3-HP-R
SMC-15-3-HP-R

SMC-15-6-HP-R
SMC-15-6-HP-R

SMC-18-3-HP
SMC-18-3-HP

SMC-18-6-HP
SMC-18-6-HP

OMC-18-HP
OMC-18-HP

HP-MNT-18-WR42
HP-MNT-18-WR42

SMC-18-3-HP-R
SMC-18-3-HP-R

SMC-18-6-HP-R
SMC-18-6-HP-R

SMC-23-3-HP
SMC-23-3-HP

SMC-23-6-HP
SMC-23-6-HP

OMC-23-HP
OMC-23-HP

HP-MNT-23-WR42
HP-MNT-23-WR42

SMC-23-6-HP-R
SMC-23-6-HP-R

SMC-26-3-HP-R
SMC-26-3-HP-R

SMC-26-3-HP
SMC-26-3-HP

SMC-26-6-HP
SMC-26-6-HP

NA
NA

HP-MNT-26-WR42
HP-MNT-26-WR42

SMC-26-3-HP-R
SMC-26-3-HP-R

SMC-26-6-HP-R
SMC-26-6-HP-R

SMC-28-3-HP

SMC-28-6-HP

NA

HP-MNT-28-WR28

SMC-28-3-HP-R

SMC-28-6-HP-R

SMC-32-3-HP

SMC-32-6-HP

NA

HP-MNT-32-WR28

SMC-32-3-HP-R

SMC-32-6-HP-R

SMC-38-3-HP
SMC-38-3-HP
SMC-38-3-HP

SMC-38-6-HP
SMC-38-6-HP
SMC-38-6-HP

HP-MNT-38-WR28
HP-MNT-38-WR28
HP-MNT-38-WR28

SMC-38-3-HP-R
SMC-38-3-HP-R
SMC-38-3-HP-R

SMC-38-6-HP-R
SMC-38-6-HP-R
SMC-38-6-HP-R

HP ODUs - 13 GHZ
HP-13-xxxx-xx
HP2-13-xxxx-xx

AD13G-xx-S2, -R2
AD13G-xx-S2, -R2

HP ODUs - 15GHZ
HP-15-xxxx-xx
HP2-15-xxxx-xx

AD15G-xx-S2
AD15G-xx-S2

HP ODUs - 18 GHZ
HP-18-xxxx-xx
HP2-18-xxxx-xx

AD18G-xx-S2, R2
AD18G-xx-S2, R2

HP ODUs - 23 GHZ
HP-23-xxxx-xx
HP2-23-xxxx-xx

AD23G-xx-S2, -R2
AD23G-xx-S2, -R2

HP ODUs - 26 GHZ
HP-26-xxxx-xx
HP2-26-xxxx-xx

AD26G-xx-S2
AD26G-xx-S2

HP ODUs - 26 GHZ
HP-28-xxxx-xx

AD28G-xx-R2

HP ODUs - 32 GHZ
HP-32-xxxx-xx

AD32G-xx-R2

HP ODUs - 38 GHZ
HP-38-xxxx-xx
HP-38-xxxx-xx
HP2-38-xxxx-xx

AD38G-xx-R2
AD38G-xx-R2
AD38G-xx-R2

TrangoSystems,Inc.

OMC-38-HP
OMC-38-HP
OMC-38-HP

GigaPlusUserManualRev1.3

215

AppendixFLinkInstallandCommissioningLogs
Standardizedformsareprovidedhereforuseduringtheinstallationandconfiguration
phaseandtoserveasarecordofthelinkperformanceatthetimeofinstallation.

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

216


SiteInformation
Customer:
SiteName:

SiteAddress:

SiteCoordinates:

IDUModel:

IDUSerial#

ODUModel:

ODUSerial#

SiteAccessnotes:

AntennaInformation
Antennamodel

Antennasize

HeightaboveGroundLevel

DoesitmeetFresnelzonerequirement?

YesNo

AntennaMountisproperlysecure?

YesNo

IstheAntennaproperlysecure?

YesNo

IstheMountProperlygrounded?

YesNo

IstheAntennaProperlygrounded?

YesNo

IstheAntennasidestrutinstalled?

YesNo

IstheAntennaweatherproof?

YesNo

WastheORinginstalledproperly?

YesNo

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

217

OutdoorUnitInformation
ModelofODU:

DirectorRemoteODUMount

DirectRemote

Areallfourlatchesproperlyclosed?

YesNo

WhatistheODUpolarization?

HV

DoestheODUlookdamaged?

YesNo

IstheGoreVentdamaged?

YesNo

PowerSupplyInformation
TypeofpowerSupply:

RedundantpowertotheIDU?

YesNo

MeasureinputvoltageatIDU

(VDC)

ProperlygroundedtotheEarth?

YesNo

Aretheleadsproperlyterminatedtothepower
supplysterminalblock

YesNo

IFCableInformation
Cabletype:

CableLength:

SecureconnectiontotheODU?

SecureconnectiontotheIDU?

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

218

Properweatherproofingatallnecessary
Points?

YesNo

Pointofentryproperlyweatherproof?

YesNo

Pointofentryproperlygrounded?

YesNo

IsthereadriploopattheODU?

YesNo

Lightningsuppressoratbaseoftower

YesNo

Remarks:

Model:
LightningsuppressoratODU

YesNo
Model:

Isthereanydamagetothecable,bends,
kinks,etc.?

YesNo
Remarks:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

219

Notes:

InstallationPerformedby:
Name:

Date:

Title:

ContactNumber:

Company:

Signature:

InstallationApprovedby:
Name:

Date:

Title:

ContactNumber:

Company:

Signature:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

220

LinkConfigurationLog
SiteAInformation
Customer:
SiteName:

SiteAddress:

SiteCoordinate:

SiteConfiguration:

1+0/1+1/2+0(CircleOne)

SiteAccessnotes:

CompleteafterLinkConfigurationcompleted
SiteAConfigurationPerformedby:
Name:

Date:

Title:

ContactNumber:

Company:

Signature:

SiteAConfigurationApprovedby:
Name:

Date:

Title:

ContactNumber:

Company:

Signature:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

221

SiteAUnit#1Information
ModelofODU

ODUSerialNumber

IDUSerialNumber

IDUMACAddress
IDUIPAddress

OBM:
IBM:

Polarizationofthisunit

VorH

AntennaModel

AntennaSerialNumber

TransmitFrequencySetting

MHz

TransmitPowerSetting

dBm

Speed/ModulationSetting

AdaptiveCoding&Modulation

ON/OFF

AutomaticTransmitPowerControl

ON/OFF

TargetRSSISetting

dBm

RecordedRSSI

dBm

ExpectedRSSIfromPCN

dBm

RecordedMSE

dB

Linktest99:stableRSSI,MSE,Lock?

Yes/No

24HourTrafficTest

NoErrorsPass/Errors:Fail

Utype

Active/Standby

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

222

SiteAUnit#2Information
ModelofODU

ODUSerialNumber

IDUSerialNumber

IDUMACAddress
IDUIPAddress

OBM:
IBM:

Polarizationofthisunit

VorH

CombinerModel

CombinerSerialNumber

TransmitFrequencySetting

MHz

TransmitPowerSetting

dBm

Speed/ModulationSetting

AdaptiveCoding&Modulation

ON/OFF

AutomaticTransmitPowerControl

ON/OFF

TargetRSSISetting

dBm

RecordedRSSI

dBm

ExpectedRSSIfromPCN

dBm

RecordedMSE

dB

Linktest99:stableRSSI,MSE,Lock?

Yes/No

24HourTrafficTest

NoErrorsPass/Errors:Fail

Utype

Active/Standby

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

223

SiteBInformation
Customer:
SiteName:

SiteAddress:

SiteCoordinate:

SiteConfiguration:

1+0/1+1/2+0(CircleOne)

SiteAccessnotes:

CompleteafterLinkConfigurationcompleted
SiteBConfigurationPerformedby:
Name:

Date:

Title:

ContactNumber:

Company:

Signature:

SiteBConfigurationApprovedby:
Name:

Date:

Title:

ContactNumber:

Company:

Signature:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

224

SiteBUnit#1Information
ModelofODU

ODUSerialNumber

IDUSerialNumber

IDUMACAddress
IDUIPAddress

OBM:
IBM:

Polarizationofthisunit

VorH

AntennaModel

AntennaSerialNumber

TransmitFrequencySetting

MHz

TransmitPowerSetting

dBm

Speed/ModulationSetting

AdaptiveCoding&Modulation

ON/OFF

AutomaticTransmitPowerControl

ON/OFF

TargetRSSISetting

dBm

RecordedRSSI

dBm

ExpectedRSSIfromPCN

dBm

RecordedMSE

dB

Linktest99:stableRSSI,MSE,Lock?

Yes/No

24HourTrafficTest

NoErrorsPass/Errors:Fail

Utype

Active/Standby

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

225

SiteBUnit#2Information
ModelofODU

ODUSerialNumber

IDUSerialNumber

IDUMACAddress
IDUIPAddress

OBM:
IBM:

Polarizationofthisunit

VorH

CombinerModel

CombinerSerialNumber

TransmitFrequencySetting

MHz

TransmitPowerSetting

dBm

Speed/ModulationSetting

AdaptiveCoding&Modulation

ON/OFF

AutomaticTransmitPowerControl

ON/OFF

TargetRSSISetting

dBm

RecordedRSSI

dBm

ExpectedRSSIfromPCN

dBm

RecordedMSE

dB

Linktest99:stableRSSI,MSE,Lock?

Yes/No

24HourTrafficTest

NoErrorsPass/Errors:Fail

Utype

Active/Standby

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

226

AppendixGDeclarationofConformity
We,TrangoSystems,Inc.,

14118StoweDrive
SteB
Poway,California,92127USA
Tel+18583910010
Fax+18583910020

Herebydeclarethattheproduct(s)listedbelow,
Product Name:
Model No:

TrangoLINK GigaPLUS Indoor Unit,100Mbps Full Duplex,1/2 U rack mnt


GIGAPLUS-IDU-1

Product Name:
Model No:

High Power Outdoor Unit 6-38 GHz


HP-XX-YYYY-ZZ, HP2-XX-YYYY-ZZ

Where:
XX = the Frequency Band in GHz
YYYY= the T/R Spacing
ZZ= the Sub-band
Towhichthisdeclarationrelates,areinconformitywiththefollowingstandardsand/orothernormative
documents:

EN30221722(200704)
EN30221721(200508)
EN30148917v1.2.1(200208)
EN609501/IEC609501:2001FirstEdition
EN50385:2002

Weherebydeclarethatallessentialradiotestsuiteshavebeencarriedoutandthattheabovenamed
productsareinconformitywithalltheessentialrequirementsofDirective1999/5/EC.
TheconformityassessmentprocedurereferredtoinArticle10(5)anddetailedinAnnexIVofDirective
1999/5/EChasbeenfollowedwiththeinvolvementofthefollowingNotifiedBodyusingtheCBScheme:

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

227

Glossary
AGC
ATPC
BER
BPF
Cat5e
COS
dB
dBm
E1
FCC
FEC
FPGA
FTP
GigE
HTTP
HTTPD
HTTPS
IF
IDU
LB
LDPC
LED
LIU
MSE
ODU
Opmode
OS
PIC
PoE
QAM
QoS
QPSK
RF
RJ45
RS232
RSSI
Rx
SFP
SNMP
SSH
Sysinfo

AutomaticGainControl
AutomaticTransmitPowerControl
BitErrorRate
BandPassFilter
Category5enhancedCable
ClassOfService
Decibel
Decibelrelativetoonemilliwatt
EuropeanCarrier1
FederalCommunicationCommission
ForwardErrorCorrection
FieldProgrammableGateArray
FileTransferProtocol
GigabitEthernet
HyperTextTransferProtocol
HyperTextTransferProtocolDaemon
HyperTextTransferProtocolSecure
IntermediateFrequency
IndoorUnit
Loopback
LowDensityParityCheck
LightemittingDiode
LineInterfaceUnit
MeanSquareError
OutdoorUnit
OperationMode
OperatingSystem
ASeriesofmicrocontrollersaproductoftheMicrochipTechnology
PowerOverEthernet
QuadratureAmplitudeModulation
QualityofService
QuadraturePhaseShiftKeying
RadioFrequency
RegisteredJack45
RecommendedStandard232
ReceiveSignalStrengthIndicator
Receive
SmallFormfactorPluggable
SimpleNetworkManagementProtocol
SecureShell
SystemInformation

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

228

T1
TDM
T/I
TFTP
TFTPD
Tx
VLAN
WISP

1.544Mbpstelephonycarrier1
TimeDivisionMultiplexing
ThresholdtoInterference
TrivialFileTransferProtocol
TrivialFileTransferProtocolDaemon
Transmit
VirtualLocalAreaNetwork
WirelessInternetServiceProvider

TrangoSystems,Inc.

GigaPlusUserManualRev1.3

229

Вам также может понравиться