Design Internal Pressure (for Hydrotest)

Design Internal Temperature


Type of Hydrotest
Hydrotest Position

0.0000
0

kgf/cm
C

not Specified
Horizontal

Projection of Nozzle from Vessel Top

0.0000

mm

Projection of Nozzle from Vessel Bottom

0.0000

mm

Minimum Design Metal Temperature


Type of Construction

-29
Welded

Special Service

None

Degree of Radiography

RT 1

Miscellaneous Weight Percent

0.0

Use Higher Longitudinal Stresses (Flag)

Select t for Internal Pressure (Flag)

Select t for External Pressure (Flag)

Select t for Axial Stress (Flag)

Select Location for Stiff. Rings (Flag)

Consider Vortex Shedding

Perform a Corroded Hydrotest

Is this a Heat Exchanger

No

User Defined Hydro. Press. (Used if > 0)

0.0000

kgf/cm

User defined MAWP

0.0000

kgf/cm

User defined MAPnc

0.0000

kgf/cm

Load Case 1

NP+EW+WI+FW+BW

Load Case 2

NP+EW+EE+FS+BS

Load Case 3

NP+OW+WI+FW+BW

Load Case 4

NP+OW+EQ+FS+BS

Load Case 5

NP+HW+HI

Load Case 6

NP+HW+HE

Load Case 7

IP+OW+WI+FW+BW

Load Case 8

IP+OW+EQ+FS+BS

Load Case 9

EP+OW+WI+FW+BW

Load Case 10

EP+OW+EQ+FS+BS

Load Case 11

HP+HW+HI

Load Case 12

HP+HW+HE

Load Case 13

IP+WE+EW

Load Case 14

IP+WF+CW

Load Case 15

IP+VO+OW

Load Case 16

IP+VE+EW

Load Case 17

NP+VO+OW

Load Case 18

FS+BS+IP+OW

Load Case 19

FS+BS+EP+OW

Wind Design Code


Basic Wind Speed

ASCE-7 93
[V]

Surface Roughness Category

112.65
C: Open Terrain

Importance Factor
Type of Surface
Base Elevation
Percent Wind for Hydrotest

km/hr

1.0
Moderately Smooth
0.0000
33.0

Using User defined Wind Press. Vs Elev.

Damping Factor (Beta) for Wind (Ope)

0.0100

Damping Factor (Beta) for Wind (Empty)

0.0000

Damping Factor (Beta) for Wind (Filled)

0.0000

Seismic Design Code

UBC 94

UBC Seismic Zone (1=1,2=2a,3=2b,4=3,5=4)

0.000

UBC Importance Factor

1.000

UBC Soil Type

S1

UBC Horizontal Force Factor

3.000

UBC Percent Seismic for Hydrotest

0.000

cm

Design Nozzle for Des. Press. + St. Head

Consider MAP New and Cold in Noz. Design

Consider External Loads for Nozzle Des.

Use ASME VIII-1 Appendix 1-9

Material Database Year

Current w/Addenda or Code Year

Configuration Directives:

Do not use Nozzle MDMT Interpretation VIII-1 01-37

No

Use Table G instead of exact equation for "A"

Yes

Shell Head Joints are Tapered

Yes

Compute "K" in corroded condition

Yes

Use Code Case 2286


Use the MAWP to compute the MDMT
Using Metric Material Databases, ASME II D

No
Yes
No

Complete Listing of Vessel Elements and Details:

Element From Node

10

Element To Node

20

Element Type
Description

Elliptical
Tampo Esquerdo

Distance "FROM" to "TO"

4.0000

cm

Element Outside Diameter

594.00

mm

Element Thickness

3.8000

mm

Internal Corrosion Allowance

0.0000

mm

Nominal Thickness

0.0000

mm

External Corrosion Allowance

0.0000

mm

Design Internal Pressure

10.300

kgf/cm

Design Temperature Internal Pressure


Design External Pressure

30
0.0000

C
kgf/cm

Design Temperature External Pressure


Effective Diameter Multiplier
Material Name

1.2
SA-414 E

Allowable Stress, Ambient

1307.7

kgf/cm

Allowable Stress, Operating

1307.7

kgf/cm

Allowable Stress, Hydrotest

1700.0

kgf/cm

0.007750

kgm/cm

Material Density
P Number Thickness

31.750

mm

Yield Stress, Operating

2671.7

kgf/cm

UCS-66 Chart Curve Designation


External Pressure Chart Name
UNS Number
Product Form

A
CS-2
K02704
Sheet

Efficiency, Longitudinal Seam

0.7

Efficiency, Circumferential Seam

0.7

Elliptical Head Factor

2.0

Вам также может понравиться