Volume 1, No 4, 2011
Copyright 2010 All rights reserved Integrated Publishing Association
RESEARCH ARTICLE
ISSN - 0976-4259
ISSN - 0976-4259
different configurations. The different configurations of battery and solar array with system
cost are shown in figure 2.
Battery
Sun
Radiations
DC
Controller,
MPPT
DC
DC Loads
DC
DC
SPV
Array
Inverter
DC to AC
AC Loads
500
15
400
12.5
10
300
7.5
200
100
2.5
Cost ( ` ) x 10000
0
1
7 8 9 10 11 12 13 14 15 16 17 18
Different Configration
Figure 2: Different configurations of battery and solar array with system cost
The impact of tilt angle on sizes of the SPV system was scrutinized for the given load
demand (Bhuiyan and Ali 2003), the optimal size of solar array and battery was obtained
when the tilt angle was adjusted in accordance with seasons. Based on the spirit of Borowys
method (Salameh and Borowy 1996), this paper scrutinizes optimum sizes of solar array and
952
ISSN - 0976-4259
battery in the SPV system under the conditions of a fixed tilt angle and continuous size
variations of solar array and battery. For the chosen LPSP at the given load demand, the
optimal size unification is acquired at the minimum system cost. Our case study shows the
procedure of the size optimization of the SPV system in Indian weather conditions.
2. Methodology
2.1. Everyday energy generation of a solar array
As the solar radiations incident on solar array of SPV system the energy is generated. This
output of a solar array rests on solar irradiation, temperature of solar cell and the operating
point of the SPV system. The solar irradiation is the integration of solar radiation of a day.
Solar arrays are rated at a solar radiation level of 1000 W/m2 and temperature of a solar cell is
25C, the peak sun hours (PSHs) are often used to represent solar irradiation so that the daily
output of the solar array is easily calculated by using the peak watt (W p ) of solar array times
the PSHs, where the PSHs is equivalent to the length of time in hours at a solar radiation
level of 1000 W/m2 (Markvart 2000).
The temperature of solar cell significantly affects the output power of a solar array. The
temperature of solar cell (Tc ) can be estimated by using ambient temperature (Ta ) and solar
radiation (Messenger 2004, Shen et al. 2005).
Tc = Ta . (1+1.25 )
(1)
(2)
Here, is the negative temperature coefficient of power with respect to solar cell
temperature; Pspv max ima is the maximum power output of the solar array under a solar radiation
of 1000 W/m2. other and connection are the factors representing other losses (caused by
accumulative dust, etc.) and connection losses respectively.
953
ISSN - 0976-4259
charge/discharge cycles, the estimation of the battery state of charge (SOC) is complicated
(Piller et al.2001). In this study, battery charge/discharge efficiency is adopted to estimate
daily battery SOC. Since the battery discharge efficiency is normally assumed to be 100%,
the battery charge efficiency is considered to be the round-trip efficiency which can normally
be found in the battery specifications.
The energy stored in the battery on the x day during the charging period is calculated by,
E ( x)
(3)
and the energy stored in the battery on x day during the discharging period is calculated by,
E ( x)
inverter
(4)
Here, the energy stored in the battery on the x and x-1 day are EBatt ( x) and EBatt ( x 1)
respectively; s is the daily battery self-discharge rate; Espy ( x) is the energy generated by
the solar array on x day; Eload ( x) is the load demand on x day; inverter is the efficiency of
the inverter and battery is the charge efficiency of the battery. The energy stored in the
battery on any x day is within the following limits,
(5)
Here EBatt max ima is the maximum allowable energy level which is equal to the rated capacity
of the battery AH battery times the rated voltage Vr and EBatt min ima is the minimum allowable
energy level which must be remain in the battery for each cycle to have the battery life as
stated in the battery specifications.
EBatt min ima is determined by the maximum depth of discharge (DOD) or minimum
SOC,
(6)
954
SOC ( x) =
ISSN - 0976-4259
EBatt ( x)
AH battery .Vr
(7)
(8)
It means LPSP is the probability of the SOC at any x day, within a period of X days, to be
less than or equal to the minimum allowable energy level EBatt min ima . Hence, the LPSP can be
calculated by
LPSP =
X
x =1
X
LES ( x)
E ( x)
x =1 load
(9)
(10)
955
ISSN - 0976-4259
The LPSP of the solar photovoltaic system is calculated by Eq. (9). By using different size
combinations of solar array and battery can meet the given load demand for the desired LPSP.
To determine the optimal size combination, the cost function of the SPV system is defined as,
(11)
where sys is the total costs of the systems; Wspv is the capacity of the solar array; AH battery is
the capacity of the battery; oth is the other total costs except the solar array and the battery,
which is considered to be constant, including the costs of the controller with MPPT, inverter,
etc. is the unit cost of the battery (`/Ah), is the unit cost of the solar array (`/Wp). From (11),
the condition to minimize sys is:
AH battery
Wspv
(12)
400
350
300
250
200
340
360
380
400
420
440
460
956
ISSN - 0976-4259
By using graphical methods we solve the Eq. (12), in the way that the two curves will be
drawn in the AH battery versus Wspv coordinate system, Figure 3. One curve represents different
size combinations of the solar array and battery for the desired LPSP. The other curve is the
line with a slope of ( / ). The tangent point of the two curves corresponds to the optimum
sizes of solar array and battery.
3. Case study for local weather conditions
By the above introduced method we solve a case study for the size optimization of solar
photovoltaic system based on Indian (Jodhpur-Rajasthan) weather conditions. The solar
radiation data is used in the optimization process which is taken from India Meteorological
Department, Ministry of Earth Sciences, New Delhi.
The load profile (Chronological load curve) of a typical house in remote areas in India
(Jodhpur-Rajasthan) is shown in figure 4. The details of the corresponding load profile are
shown in table 1(a) & (b).
Table 1(a)
Load
Symbol
CFL-1
CFL-2
Ceiling Fan
Table Fan
TV
C1
C2
CF
TF
TV
Rating in
Watt
25
11
60
25
70
Table 1(b)
Time Schedule
Loads Used
Power(Watts)
Energy (Wh)
12 midnight to 6 am
6 am to 7 am
6 am to 8 am
8 am to 9am
9 am to 5 pm
5 pm to 6 pm
6 pm to 7 pm
7 pm to 8 pm
8 pm to 11 pm
10 pm to 11 pm
11 pm to 12 pm
Total Energy
TF
TF+C2
TF+CF
TF+TV
CF
CF+TF
CF+TF+C2
CF+C1+C2+TF
CF+C1+C2+TV
TF+C2
TF
25
36
85
95
60
85
96
121
166
36
25
150
36
170
95
480
85
96
121
498
36
25
1792
957
ISSN - 0976-4259
It is assumed that the battery DOD cannot be higher than 0.8 or the SOC cannot be lower
than 0.2; the desired LPSP of the system is set to 0.01 which means there is 14.4 min poweroff within one day or 3.65 days power-off within one year. With the help of the program
developed by using the MATLAB, the LPSPs for different size combinations of solar array
and battery are calculated. Figure 5 shows the calculated results in 3D plot.
180
160
L o a d d e m a n d (W a tt)
140
120
100
80
60
40
20
0
0
10
15
Time(Hours)
20
25
Figure 3 shows the different size combinations of solar array and battery at an LPSP of 0.01
by adding the line with a slope of (/), where = 78 (`/Ah) and =112 (`/Wp). The
tangent point of the two curves corresponds to the optimal size combination of solar array
and battery which are approximately equal to 300 Ah and 375 Wp, respectively.
If the commercial availability of solar array and battery is taken into account, 3 battery units
with 100 Ah and 5 solar modules with 75 Wp are selected. With this optimum configuration,
daily energy generation and battery SOC over the year are evaluated and the corresponding
results are shown in figures 6 & 7, respectively (Ajit 2009).
For the LPSP of 0.01, the size ratio of battery to solar array in this case study is about 0.69
Ah/Wp (300 Ah/375Wp) while the size ratio of battery to solar array in is about 0.84 Ah/Wp.
958
ISSN - 0976-4259
0.25
LPSP
0.2
0.15
0.1
0.05
100
250
200
300
350
300
400
400
450
Figure 5: 3D plots of different size combinations of solar array and battery at different LPSP
values.
30
25
20
15
10
0
0
50
100
150
200
250
300
350
Day
Figure 6: Daily sum of solar radiant exposure in India (1 kWh = 3.0 MJ)
959
ISSN - 0976-4259
1
0.9
0.8
B attery SO C
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
50
100
150
200
250
300
350
Day
2.
Arora D.S. , Busche Sarah, Cowlin Shannon, Engelmeier Tobias, Jaritz Hanna,
Milbrandt Anelia, Wang. Shannon, (2010), Indian Renewable Energy Status Report,
Background Report for DIREC 2010, NREL, October, 55-75.
960
ISSN - 0976-4259
3.
Bhuiyan MMH, Ali Asgar M. (2003), Sizing of a standalone photovoltaic power system
at Dhaka Renewable Energy; 28, pp 929938.
4.
Dr. Ajit P. Tyagi, Solar Radiant Energy over India (2009), Ministry of New and
Renewable Energy, India Meteorological Department; pp 3808-3819.
5.
Markvart Tomas, (2000), Solar electricity, 2nd ed. John Wiley & Sons Inc, pp 9598.
6.
Messenger Roger A, Ventre Jerry, (2004), Photovoltaic systems engineering 2nd ed.
CRC Press LLC, pp 7679.
7.
Piller Sabine, Perrin Marion, Jossen Andreas., (2001), Methods for state of charge
determination and their applications Journal of Power Sources; 96, pp 113120.
8.
Salameh Ziyad M, Borowy Bogdan S. (1996), Methodology for optimally sizing of the
combination of a battery bank and PV array in a wind/PV hybrid system IEEE
Transactions on Energy Conversion; 11(2), pp 367375.
9.
Shen Weixiang, Tan Wei Kuang, Kok Bin Alex See, Kok Seng Ong., (2005), Sizing of
standalone photovoltaic system using Matlab/Simulink, Proceedings of the international
conference on robotics, vision, information and signal processing, Penang, Malaysia, pp
288293.
10. Shen W.X., (2009), Optimally sizing of solar array and battery in a standalone
photovoltaic system in Malaysia, Renewable Energy; 34, pp 348352
11. Shrestha GB, Goel L., (1998), A study of optimal sizing of standalone photovoltaic
stations, IEEE Transactions on Energy Conversion; 13(4), pp 373378.
12. Sidrach-de-Cardona M, Mora Lopez Li., (1998), A simple model for sizing stand-alone
photovoltaic systems Sol Energy Mater Sol Cells, 55, pp 119214.
961