Вы находитесь на странице: 1из 2

Cach Instrumentation

Technical Datasheet

Deltaflux Shunt Orifice Flowmeter


Construction & Specification
Main Orifice Carrier

316 stainless steel orifice mounted in


polyester coated carbon steel carrier

Bypass Flow Indicator

Nickel-plated copper tubing and brass


connections
Borosilicate glass indicator tube
Viton and polyurethane seals

Float Material

Stainless on liquid or
Anodised aluminium on gas

Operating Pressure

20 bar non shock

Operating Temperature

-15C to 90C

Connections

Flange Wafer style bolted between


flanges DIN or BS10 table E or D
Groove Style Optional

Accuracy

2% FSD

Features & Benefits


Direct reading scale
Liquid and gas flows
Wafer Flange and Groove style connections
Compact construction
Vertical and horizontal mounting
10:1 turndown
Integral bleed and drain nuts
Full bore isolation valves
Optional alarm

Easily installed and operated


Suited to most common applications
Installation flexibility
Pipeline or remote panel mounted
Suitable for many pipe and flow orientations
Reduced measurement points
Assured operation
Maintenance without breaking connection
Modular system upgrades

Cach Instrumentation Ltd Oakwood House 332A Horbury Road Lupset Wakefield WF2 8JQ
T: +44 (0)1924 378844 F: +44 (0)1924 378855 E: sales@cacheuk.com W: www.cacheuk.com

Cach Instrumentation
Flow Ranges

Technical Datasheet

For standard schedule 40 pipes

Pipesize
mm

H20
m3/hr @ 20C

Scale Code

H20
m3/hr @ 20C

Scale Code

Air
m3/hr @ 20C - 1.013 bar

Scale Code

38

2 - 20

WA 85

2 - 10

WA 91

20 - 150

AI 85

50

5 - 40

WA 86

4 - 20

WA 92

40 - 300

AI 86

80

10 - 100

WA 87

10 - 50

WA 93

100 - 700

AI 87

100

20 - 200

WA 88

20 - 100

WA 94

200 - 1500

AI 88

150

50 - 400

WA 89

40 - 200

WA 95

500 - 3500

AI 89

100 - 1000
WA 90
80 - 400
WA 96
1000 - 7000
200
* Unrecovered pressure
400 mbar
100 mbar
40 mbar
loss at MAX flow
2
* Pressure loss at operating flows = Pressure loss at MAX flow x (Operating flow / MAX flow)

AI 90

Installation & Mounting Dimensions


The achievable accuracy of the Deltaflux
flowmeter is a function of installation. For

10 d

5d

40mm

best results, minimum straight lengths of


pipe 10 diameter upstream and 5 diameter

downstream are recommended

Options & Accessories

Grooved style main orifice carriers are available, suitable for use with standard clamp style connectors.

Alternative materials of construction are available, including all 316 ss and plastic construction.

Remote siting of the indicator, up to 10 metres from the main orifice carrier can be accommodated
using flexible nylon tube.

The indicator can be fitted with a high, low or dual infrared alarm

Customised flows for specific operating conditions.

Additional Sizes and ranges are available on request

Ordering Codes
Pipe Size (mm)

Example
Order Code

Flow range

80

10 - 50m3/hr

Fluid Type

H20

DF 80 - WA 93

Cach Instrumentation Ltd Oakwood House 332A Horbury Road Lupset Wakefield WF2 8JQ
T: +44 (0)1924 378844 F: +44 (0)1924 378855 E: sales@cacheuk.com W: www.cacheuk.com