Академический Документы
Профессиональный Документы
Культура Документы
TableofContents
OurOverallOilandPetrochemicalDivisionOverview
ServicesOfferedbyUs
SectorsServiceOfferings
TankCalibrationServices
I.
EODRMethodology
II.
ORLMMethodology
III.
ManualStrappingMethodology
ContactDetails
ExtensiveGeographicFootprint
EMEA
France
AsiaPacific
Americas
365locations
and110laboratories
170locations
and10laboratories
220locations
and130laboratories
185locations
and90laboratories
13,700staff
7,600staff
18,100staff
12,700staff
22countries
30countries
87countries
Europe excludingFrance
MiddleEast,Africa
Globalnetworkcomprisingmorethan940locations
and340laboratoriesacross140countries
OurOverallIndiaOilandPetroleumOverview
StrongQuality
&ServiceFocus
Certified ISO 9001:2008, NABL (ISO
17025) Certified Laboratory .
Testing
&
Stateoftheart
facilities
ServicesOfferedbyUs
Inspection:Itis,most
generally,anorganized
examinationorformal
evaluationexerciseinlines
withsomestandard
guidelinestodetermine
thesuitability/fitnessofa
commoditybeinginvolved
intradingbywayof
measurementsandtests.
TheInspectionprocess
givesconfidencetothe
enduserofthecommodity
aswelltothesupplier.
- Copyright Bureau Veritas
Testing:Itisaverification
processtofindoutthe
valuesofthedifferent
parametersinvolvedto
determinethequalityof
thecommoditybeing
tradedorusedbythe
differentindustriesand
theconsumerworlds.
Testingprocessgivesthe
indicationofthesuitability
ofthecommodityfor
usageortrading.
Calibration: Inspectorateis
specializedincalibrationof
VerticalorHorizontal
shoretanks,adoptingsuch
techniquesasLaser
DistanceandAngles
Technologywithprecise
accuracy.Lasertechnology
enablesthecalibrationof
shoretankswithout
scaffolding,thereby
avoidingadditionalcost
anddisruption.
TankCalibration
Whetheryouhavenewlyconstructedtanksandprovers,ourexperiencedfieldteamswillmeetorbeatyour
scheduledcalibrationexpectations.
KeyCapabilities
Providingreliablemeasurementsandcalculationsfor:
VerticalCylindricalStorageTanks
HorizontalStorageTanks
SphericalStorageTanks
FloatingRoofZones
ApprovalsfromGovt.StatutoryAuthority
KeyBenefits
Calibratingtechniquesusedinaccordancewiththemost
currentAmericanPetroleumInstitute(API),Manualof
PetroleumMeasurementStandards(MPMS)andBIS
standardsandprotocols;
Safetydriven,qualityworkmanship
InspectorateIndia SolutionsforTankCalibration
VerticalCylindricalStorageTanks
ManualStrappingMethod:(ISO7507PartIorAPIMPMS2.2A)
OpticalReferenceLineMethodbyLaserEquipment:(ISO7507PartIIorAPIMPMS2.2B)
ElectroOpticalDistanceRangingMethod:(ISO7507Part IVandPartVorAPIMPMS2.2D)
HorizontalStorageTanks
ManualPhysicalMeasurementMethod:(ISO129171,API2551)
TiltedHorizontalStorageTankbyLiquidFillingorWaterDrawMethod:(API2555)
SphericalStorageTanks
SphereandSpheroidsTankcalibration:(API2552)
ApprovalsfromGovt.StatutoryAuthority
(EODR)ElectroOpticalDistanceRangingMethod
EODRMethodology
Measurementofreferencecircumferencebymanualstrappingmethod.
Verticalmeasurementoftankshellbyusingelectroopticaldistanceranginginstrument.
Bottommeasurementbyusinghorizontalautolevelorlaserlevel&levelingstaff.
Accuratemeasurementofpositive,negativedeadwoods,referenceheight&anyotheraccessoriesthatmay
affectontankworkingheight&tankvolume.
Calibrationchartcalculations&preparationofcalibrationchart.
EODRAdvantages
Moresafe: ThedangeroffallingfromtheladdersorBosonchairiseliminated.Verticalmeasurementoftank
shellbyusingelectroopticaldistanceranginginstrument.
LessCumbersome: Themethodeliminatesanymovementofheavyequipmentsuchashoists,bosonchairsor
ladders.
MoreEconomical:Lesspersonsarerequiredduringconventionalstrapping&ORLMvis avis EODRmethod.
MoreAccurate:Cancelsouthumanrandomerrorscausedduetofatigue,environmentalinfluences,improper
markings,Trolleymovementatproperpositionetc.
DeterminationofFirstShellReferenceCircumference
3
20%OFTOTALSHELL
HEIGHTFROM
BOTTOMWELD
TANK
SHELL
HORIZONTAL
WELDS
20%OFTOTAL
SHELLHEIGHT
FROMTOPWELD
1
MARKING
THETAPE
PATH
- Copyright Bureau Veritas
10
PhysicalMeasurementoffirstShellCircumference
3
VERTICALWE
LDS
TANK
SHELL
2
100MTR.
MEASURING
TAPE
READING
X
TAPERISEDUETO
WELDS&STEP
OVER
MANHOLEPAD
11
EODR MeasurementStations
Measurementstationsaremarkedonthetankshell,thenumberbeingobtainedfromthistable.Stationasper
Standard.
Tankdiameters(meters)
Minimumnumberofstations
15
30
12
50
16
70
20
85
24
100
30
120
36
12
StationMarking
StationMarkingaroundthetankforverticalmeasurementbyElectroopticaldistanceranging
instrument.
1
2
STATION
DISTANCE
StationDistance=
6
Circumf./StationNo.
13
VerticalMeasurement
VerticalmeasurementofTankShellbyElectroopticaldistanceranginginstrumentbyexternal.
VerticalLevel
HorizontalLevel
a
REFERENCE
READING
EODRINSTRUMENT
- Copyright Bureau Veritas
14
EODRMethodUseforinternalMeasurement
Target
Points
a Vertical
Angle
b Horizontal
Angle
D Slope
Distance
D
a
b
15
BottomMeasurement
BottomMeasurementofbyusinghorizontallevelandlevellingStaff
0.0 MTR
0.5 MTR
1.0 MTR
1.5 MTR
Datum Plate
(Reference Point)
2.0 MTR
2.5 MTR
3.0 MTR
C
4
5
16
BottomMeasurement
BottomMeasurementofbyusinghorizontallevelandlevellingStaff
CENTRELINE
OFTHETANK
LEVELLING
STAFF
HORIZONTAL
LEVELOR
LASERLEVEL
DATUMPLATE
(REFERENCEPOINT)
REFERENCE
READING
A
CENTRE
3.0MTR
2.5MTR
2.0MTR
1.5MTR
1.0MTR
0.5MTR
0.0MTR
TANKBOTTOM
17
DeadwoodMeasurements
DIPHATCHPIPE/
GAUGINGPOINT
PONTOONFORFLOATING
ROOFTANK
MANHOLE/MANWAY
IN/OUTLET
PIPE
MANHOLE/MANWAY
HEATINGCOIL
SUPPORTFORCOIL
CENTRESUMP
27
BasicPrincipleofCalculations
a2
r1
a1
28
Brand and
Reputation
Unmatched
Expertise
Skilled
Employee Base
Broad Service
Portfolio
Acquisition
Track Record
34
Our global network of experts are dedicated to providing our leading services to
customers across the globe.
Contact Details:
Inspectorate Griffith India Pvt Ltd.,
104, 1st Floor, Hyde Park, Marol Village,
a.avasthi@inspectorate.co.in
shailendra.upadhyay@inspectorate.co.in
Email:
Websites: www.inspectorate.com
www.bureauveritas.com
35
ThankYou!!
36