14. At low level of A-R102, the mixer A-G102 will automatically stop.
15. When A-R102 is fully empty, check on the acid methanol water level at A-V102, and
discharge all the acid water level manually by visually monitoring at A-SG108.
16. Then close the discharge valves and open the bypass valve to empty A-V103to AV107.
17. Close steam supply for A-E105.
18. Drain A-V107 to A-V108 and close A-LV107
19. Empty A-V108 and purge nitrogen to clear line to A-R103.
20. When A-V108 is empty, close the acid catalyst and methanol dosing A-FV143 & AFV123 and isolating & actuator valves, A-AV143 & A-AV123 respectively.
21. Close steam supply for A-E106.
22. Close isolating valves for A-G107 and open valve at A-FI103.
23. Open nitrogen purge valve at A-R103 and empty A-R103 by carefully controlling the
flowrate at A-FI103 using the bypass valve.
24. At low level of A-R103, the mixer A-G103 will automatically stop.
25. When A-R103 is fully empty, check on the acid methanol water level at A-V103, and
discharge all the acid methanol water level manually by visually monitoring at ASG112.
26. Then close the discharge valves and open the bypass valve to empty A-V103to AV109.
27. Close steam supply for A-E108.
28. Drain A-V109 to A-V110 and close A-LV109.
29. Empty A-V110 and purge nitrogen to clear line to A-T113A/B.
30. Empty A-T113A/B and purge nitrogen to clear line to A-R104.
31. When A-T113A/B is empty, close the alkaline catalyst and methanol dosing AFV131 & A-FV124 and isolating & actuator valves, A-AV131 & A-AV124
respectively.
32. Close cooling water supply for A-E109.
Page
Date
28/04/09
Doc. No.
Rev.
01
33. Close isolating valves for A-G108 and open valve at A-FI104.
34. Open nitrogen purge valve at A-R104 and empty A-R104 by carefully controlling the
flowrate at A-FI104 using the bypass valve.
35. At low level of A-R104, the mixer A-G104 will automatically stop.
36. When A-R104 is fully empty, check on the glycerol level at A-V104, and discharge
all the glycerol level manually by visually monitoring at A-SG117.
37. Then close the discharge valves and open the bypass valve to empty A-V104 to AV202.