Вы находитесь на странице: 1из 3

Nitoflor Conductive

constructive solutions

Epoxy resin static conductive floor with


resistance between 5 x 104 and 1 x 106
ohms
Uses

Design criteria

Nitoflor Conductive is suitable for use in areas where a


static conductive with a resistance between 5x104 and 1x106
ohms is required as a measure to control static electricity.
Typical areas of use include electronics manufactures and
assembly, hospital operating theatres, hazardous dust and
chemical environments and clean rooms.

Nitoflor Conducive is designed for application at a nominal


thickness of 2 mm. It should be installed where static
conducive floor with resistance between 5 x 104 and 1 x 106
ohms is required.

For dissipative floors with different electrical characteristics,


the use of Nitoflor Dissipative should be considered (see
separate data sheet).
Advantages
Static control - provides static electricity with an effective
passage to earth.
Seamless - smooth, hygienic surface which is easily
cleaned, unlike vinyl tiles which are not seamless.
Durable - long term performance, accepts fork lift traffic,
more durable than vinyl tiles.
Attractive - wide range of colours enhances working
environment.

Nitoflor Conductive is designed to dissipate static electricity


away from the source to earth.
Substrates should be dry and not suffer, or be likely to
suffer, from rising damp. If necessary, suitable damp-proof
membranes should be installed to prevent this. Substrates
should not have a relative humidity greater than 75% at the
time of installation.
Properties
The values given below are average figures recorded in
o
laboratory tests at 20 C. Actual values obtained on-site
may show minor variations from those quoted.
Physical properties

Nitoflor Conductive has a surface resistance between 5 x


4
6
10 and 1 x 10 ohm when measured in accordance with
ASTM F150-78. Nitoflor Conductive also satisfies BS 2050
and DIN 51953. Independent test reports are available.

Compressive strength (BS 6319):


Flexural strength (BS 6319):
Tensile strength (BS 6319):
Abrasion resistance
Fed. Spec. 141A (CS 17 wheel,
1000 g, 1000 cycles):
Impact resistance
(BS 8204 Part 1):
Cure time:
Foot traffic:
Vehicular traffic:

Description

Electrical properties

Nitoflor Conductive is a 2 mm thick epoxy resin floor topping


with controlled conductive properties.

Surface resistance
(ASTM F150-78):
Bulk resistance:
(DIN 51953)
(ASTM F150-78)
Charge decay (Fed. Spec.
101 C Method 4046):
Body voltage decay
(Stephen Halperin &
Associates Ltd):

Resists most chemical spillage.


Standard compliance

The system comprises an epoxy primer, conductive epoxy


undercoat and a 2 mm thick epoxy top coat. It is available
in a wide range of attractive colours and provides a highly
durable, chemically resistant seamless floor.
Technical support
Fosroc offers a comprehensive range of high performance,
high quality repair, maintenance and construction products.
In addition, Fosroc offers a technical support package to
specifiers, end-users and contractors as well as on-site
technical assistance in locations all over the world.

60 N/mm2
2
40 N/mm
2
18 N/mm
97 mg weight loss
0.03 mm depth to
wear
0.2 mm indentation
20oC
35oC
24 hrs
18 hrs
48 hrs
36 hrs

4
6
5 x 10 to 1 x 10 ohms
4
6
5 x 10 to 1 x 10 ohms
4
5 x 10 to 1 x 106 ohms
5000 v to zero in less
than 0.1 seconds.
5000 v to Zero in 0.4
seconds using
conductive heel straps or
conducive shoes.

Chemical properties
Nitoflor Conductive provides excellent resistance to a wide
range of industrial chemicals.
For details of specific chemical resistance, consult the local
Fosroc office.

Page 1

Nitoflor Conductive
Maintenance
The service life of a floor can be considerably extended by
good housekeeping and regular cleaning. The ability of a
conductive floor to effectively control static electricity can be
affected by a surface layer of dirt, grease or other residue.
Nitoflor conducting floors should not be treated with waxes
or polishes. For specific floor maintenance schedules
consult the local Fosroc office.
Application clauses

Install the appropriate Fosroc joint sealant. This will


depend on the anticipated movement accommodation
factor and the end use of the new floor. For further
advice, consult the local Fosroc office.
Installation time will vary with site conditions, the size of the
area involved and the system chosen.
Cleaning

Static conductive epoxy floor topping


The designated floor areas shall be surfaced with Nitoflor
Conducive, a 2 mm thick flow-applied epoxy resin floor
topping. The topping shall provide a surface and bulk
4
6
resistance between 5 x 10 and 1 x 10 ohms when tested
to DIN 51953 and ASTM F150-78 respectively.
When tested to BS 6319, it shall achieve a compressive
strength of 60 N/mm2, a flexural strength of 40 N/mm2 and a
2
tensile strength of 18 N/mm . When tested to Federal
Specification 141A it shall exhibit a weight loss no greater
than 97 mg and depth of wear no greater than 0.03 mm
after 1000 cycles using a CS 17 wheel of 1000 g weight.
When tested to BS 8204, Part 1, the floor shall exhibit an
indentation after impact no greater than 0.2 mm. At 20oC, it
shall be capable of accepting foot traffic at 24 hours and
vehicular traffic after 48 hours.

Nitoflor Conductive Undercoat should be removed from


tools and equipment with clean water immediately after use.
Nitoprime 25, Nitoprime 30 and Nitoflor Conductive Topcoat
should be removed from tools and equipment using Fosroc
Solvent 102. Hardened material can only be removed
mechanically.
Limitation
Nitoflor Conductive should not be applied to slabs less than
28 days old or surfaces known to, or be likely to suffer from,
rising damp conditions or have a relative humidity greater
than 75% when measured in accordance with BS
8203:1987, Appendix A or by a Vaisala thermo-hygrometer
Type 131.
Nitoflor Conductive should not be applied to asphalt,
unmodified sand/cement screeds, PVC or vinyl surfaces.

Application instructions
Nitoflor Conductive should be installed by specialist
applicators who must follow the procedures laid down in the
Product Application Guide. Fosroc works with a network of
such applicators who have been fully trained in the correct
installation procedures.
The following steps are involved which would normally take
place over a 3 to 5 day period.
Thoroughly prepare the floor surface. Correct surface
preparation helps to achieve the necessary adhesive
bond between the substrate and the new floor.
All existing expansion or movement joints should be
followed through the new coating surface. Joints should
be cleaned and prepared.
Apply Nitoprime 25 and Nitoprime 30 and allow to cure.
Porous substrates may require two coats of primer.
Install joint and earthing connections in full accordance
with Fosroc's Product Application Guide.
Apply Nitoflor Conductive Undercoat. This provides a
conductive passage to earth and correct application and
strict adherence to coverage rates are critical to the final
electrical properties of the completed floor.

constructive solutions

Apply the Nitoflor Conductive Topping. The material is


poured on to the undercoat by brush or roller short hair
to achieve 2 mm seamless topping. Allow to harden.

Nitoflor Conductive should not be installed at temperatures


below 10oC.
For information on other substrates, consult the local Fosroc
office.
Estimating
Supply: Nitoflor Conductive is supplied in packs containing
pre-weighed components:
Binder:
Aggregate:
Colour pot:
Total:
Nitoflor Conducive Undercoat:
Nitoprime 25 and 30:
Fosroc Solvent 102:

11.8 kg packs
17.7 kg sacks
0.5 kg packs
30 kg packs
5 kg packs
5 kg packs
5 litre pack

Coverage

Nitoflor Conductive Topcoat:


Nitoflor Conductive Undercoat:
Nitoprime 25:
Nitoprime 30:

Page 2

2
18 m /packa at 2
mm thickness
2
35 m / pack
2
5 m / pack
2
5 m / pack

Nitoflor Conductive
The coverage figures given are theoretical due to wastage
factors and the variety and nature of possible substrates,
particle coverage figures will be reduced. Typically, an
additional 10% should be allowed for surface irregularities
and wastage although this will vary with site conditions.
UN packaging regulations
To comply with current regulations, all products of a
hazardous nature which are subjected to a sea crossing as
part of their delivery requirements, must be packed in UN
approved receptacles.
When a known sea crossing is involved, whether locally or
for export, Fosroc will supply in the correct UN packaging.
Where Fosroc are requested to deliver within a mainland
boundary but the Purchaser intends to onward ship, it is
incumbent upon the Purchaser to specify that UN packaging
is required at the time of placing the order.

crams provide additional skin protection. In case of contact


with skin, remove immediately with resin removing cream
followed by washing with soap and water. Do not use
solvent. In case of contact with eyes, rinse immediately with
plenty of clean water and seek medical advice.
If
swallowed, seek medical attention immediately - do not
induce vomiting.
Fire
Nitoflor Conductive base component, Nitoflor Conductive
Undercoat and Nitoprime 30 are non flammable. Nitoflor
Conductive Hardener component, Nitoprime 25 and Fosroc
Solvent 102 is flammable. Keep away from sources of
ignition. No smoking. In the event of fire extinguish with
CO2 or foam. Do not use near open flames or smoke
during use.
Flash points

Otherwise, once received, responsibility rests with the


Purchaser. The use of UN packaging may affect the selling
price of products. Please consult the local Fosroc Area
Manage or office.

Nitoflor Conductive Hardener:


Nitoprime 25:
Fosroc Solvent 102:

39oC
o
59 C
o
33 C

Disposal

Storage

Nitoflor Conductive, Nitoprime 25, Nitoprime 30 and


Nitoprime 31 have a shelf life of 12 months if kept in a dry
store in the original unopened packs.

Spillages of component products should be absorbed onto


earth, sand or other inert material and transferred to a
suitable vessel. Disposal of such spillages or empty
packaging should be in accordance with local waste
disposal regulations. For further information, refer to the
Product Material Safety Data Sheet.

Storage conditions

Additional information

Shelf life

o
o
Store in dry conditions between 5 C and 30 C, away from
sources of heat and naked flames, in the original, unopened
packs. If stored at high temperatures the shelf life may be
reduced.

Precautions
Health and safety
Nitoflor Conductive, Nitoflor Conductive Undercoat,
Nitoprime 25, Nitoprime 30 and Fosroc Solvent 102 should
not come in contact with skin or eyes, or be swallowed.
Ensure adequate ventilation and avoid inhalation of vapors.
Some people are sensitive to resins, hardeners and
solvents. Wear suitable protective clothing, gloves and eye
protection. If working in confined areas, suitable respiratory
protective equipment must be used.
The use of barrier

Fosroc manufactures a wide range of products specifically


designed for the repair and refurbishment of damaged
reinforced concrete. This includes hand-placed and spray
grade repair mortars, fluid micro-concrete, chemical
resistant epoxy mortars and a comprehensive package of
protective coatings.
In addition, a wide range of
complementary products is available. Fosroc has also
produced several educational training videos which provide
more details about the mechanisms which cause corrosion
within reinforced concrete structures and the solutions
which are available to arrest or retard these destructive
mechanisms. Further information is available from the
publication.
Concrete Repair and Protection.
The
Systematic Approach, available in seven language formats.
For further information about products, training videos or
publications, contact the local Fosroc office.

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for
the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that any
advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct or
continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the use
of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Head Office
Post Box 11081
Jeddah - 21453
Saudi Arabia

www.fosroc.com

Telephone: +966 2 637 5345

Fax: +966 2 637 5891

email: fosam@fosroc.com

Regional Offices
Jeddah Sales Office
Jeddah Showroom
Riyadh
Dammam
Khamis Mushayt

Tel: (02) 608 0999


Tel: (02) 665 0187
Tel: (01) 482 9303
Tel: (03) 814 1282
Tel: (07) 250 0469

Fax: (02) 635 3330


Fax: (02) 667 4844
Fax: (01) 482 7562
Fax: (03) 814 1581
Fax: (07) 250 0469

Yanbu
Makkah
Medinah
Jubail
CSD

Tel: (04) 322 4280


Tel: (02) 542 0869
Tel: (04) 845 1767
Tel: (03) 362 3904
Tel: (02) 608 0999

Fax: (04) 391 2980


Fax: (02) 542 0869
Fax: (04) 846 3195
Fax: (03) 362 3875
Fax: (02) 638 0693

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407

Page 3

FO SA/NITOFLOR CONDUCTIVE/05/A

Вам также может понравиться