AFPX-C14 (The same dimensions apply to the expansion I/O unit AFPX-E16)
COM
X0
X2
X5
X4
X7
X6
PROG. ERR.
3
7
3
0
X 4
0
Y 4
Programmable Controller
45
RUN
Application cassette
Communication cassette
X3
X1
FP-X
60
90
Panasonic
RUN
PROG.
FP-X C14
min.
max.
V0
V1
45
Analog volume
Tool port connector
0V
Y2
Y1
Y0
24V
C0
C1
C2
Y3
C3
Y5
Y4
13.6
3.5
Application cassette
Communication cassette
Battery
Expansion unit connector
79
8.6
79
AFPX-C30 (The same dimensions apply to the expansion I/O unit AFPX-E30)
100
N COM
COM
RUN
X1
X0
X3
X2
X5
X4
X7
X9
X8
X6
XB
XA
XD
XC
XF
XE
2-M
4o
r2
PROG. ERR.
0
8
0
Y
8
7
F
7
90
FP-X C30
RUN
PROG.
min.
82 0.5
Panasonic
max.
V0
Analog volume
V1
0V
USB connector
24V
Y0
C0
Y2
Y1
C1
C2
Y4
Y3
Y7
C3
Y5
Y6
Y9
Y8
YA
C4
YC
YB
YD
FP-X C14
Function cassette
Battery
Expansion unit connector
AFPX-C60
52 0.5
92 0.5
FP-X C30
ARCT1B273E
DIN hook
182 0.5
FP-X C60
190
N COM
COM
RUN
X
Y
X0
PROG.
X3
X2
X5
X4
7 8
17 18
7 8
17 18
XC
XF
COM
NC
XE
COM
COM
COM
X11
X13
X12
X10
X15
X14
X17
X16
X19
X18
X1B
X1A
X1D
X1C
X1F
X1E
F
1F
D
1D
FP-X C60
V1
V2
max.
V3
0V
XA
XD
max.
V0
min.
USB connector
X8
XB
Panasonic
min.
24V
X6
X9
ERR.
0
10
0
10
RUN
PROG.
Analog volume
X7
Y0
C0
Y2
Y1
C1
C2
Y4
Y3
Y7
C3
Y5
Y6
Y9
Y8
YA
C4
YC
YB
Y10
YD
C0
Y11
C1
C2
Y12
Y13
C3
C5
Y14
C4
Y15
Y17
Y16
Y19
Y18
Y1A
C6
Y1C
Y1B
Y1D
( 0.5 )
25
60
POWER
I/F
L
ERROR
45
Status
display LED
(7)
Panasonic
Expansion connector
90
AFPX-EFP0
FP0-A80
45
X1
90
2-Axis Linear
Interpolation
Simultaneously
in 2 Pairs!
DIN hook
Power connector 24 V DC
Expansion hook
30-point type
60-point type
New
Printed in Japan.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Introducing
a Transistor
Output Type
Servomotor and stepping motor control in production equipment has become increasingly
diversified while requiring a greater number of axes for example, electronic control for
replacing cams, XY table + Z-axis control for cell-production and LCD alignment, 3D bending
process of corrugated paper boxes and heat exchanger pipes, high-density coil winding
operations etc. With such applications in mind, FP-X is a compact general-purpose PLC
suited for small-scale equipment controls with its 4-axis pulse output built into the compact
body, enabling multi-axis control in a very small space at a fraction of the equipment cost.
AFPX-C60
(Add-on cassette attached)
High Security
Program protection with an 8-digit password and a function
prohibiting uploads
USB-port Equipped*3
AFPX-C30
(Add-on cassette attached)
New Functions
Easy-to-use Temperature Control
Command (F356 EZPID)
MEWTOCOL Master Function
AFPX-C14
Trace Function
2 Clearwater
Introducing
a Transistor
Output Type
Servomotor and stepping motor control in production equipment has become increasingly
diversified while requiring a greater number of axes for example, electronic control for
replacing cams, XY table + Z-axis control for cell-production and LCD alignment, 3D bending
process of corrugated paper boxes and heat exchanger pipes, high-density coil winding
operations etc. With such applications in mind, FP-X is a compact general-purpose PLC
suited for small-scale equipment controls with its 4-axis pulse output built into the compact
body, enabling multi-axis control in a very small space at a fraction of the equipment cost.
AFPX-C60
(Add-on cassette attached)
High Security
Program protection with an 8-digit password and a function
prohibiting uploads
USB-port Equipped*3
AFPX-C30
(Add-on cassette attached)
New Functions
Easy-to-use Temperature Control
Command (F356 EZPID)
MEWTOCOL Master Function
AFPX-C14
Trace Function
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
The flexible product lineup designed for rapidly responding to user needs provides a high level of satisfaction.
Control Unit
Product Lineup
Input terminals
Control Unit
Relay output
Power supply (100 to 240 V AC)
DC input: 8 (24 V DC)
Relay output: 6 (250 V AC/2 A)
Program capacity: 16 ksteps
Potentiometer: 2
AFPX-C14R
AFPX-C30R
AFPX-C60R
Transistor output
AFPX-C14TD
AFPX-C14T
AFPX-C14PD
AFPX-C14P
AFPX-C30TD
AFPX-C30T
AFPX-C30PD
AFPX-C30P
AFPX-C60TD
AFPX-C60T
AFPX-C60PD
AFPX-C60P
Expansion Unit
Power terminals
Expansion cassette interface cover
Connector for
add-on cassette
I/O status monitor LED
Connector for
expansion unit
Connector
for battery
Potentiometer
AFPX-E16R
AFPX-E16T
AFPX-E16P
Expansion Unit
(Model: Relay output type AFPX-E16R)
AFPX-E30R
Add-on Cassette
Communication cassette
AFPX-COM1
AFPX-COM2
AFPX-COM3
Communication cassette
(RS485/422 selectable 1 ch.)
AFPX-COM4
Communication cassette
(RS485 1 ch + RS232C 1 ch.)
AFPX-E30TD
AFPX-E30T
AFPX-E30PD
AFPX-E30P
AFPX-COM5
(Avail. April 2007)
AFPX-EFP0
Communication cassette
(Ethernet 1 ch + RS232C 1 ch.)
Application cassette
AFPX-IN8
AFPX-TR8
Output cassette
(NPN transistor 0.3 A, 8 output ch.)
AFPX-AD2
AFPX-PLS
AFPX-MRTC
W
NE
Input terminals
Specifications
FP0-E8X
FP0-E16X
FP0-E8YT
FP0-E8YRS
FP0-E16T
FP0-E16P
FP0-E32T
FP0-E32P
FP0-E8RS
FP0-E16RS
FP0-A21
FP0-A80
FP0-A04V
FP0-A04I
FP0-TC4
FP0-TC8
FP0-IOL
FP0-CCLS
FP0-E32RS*1
FP0-RTD6*1
FP0-DPS2*1
Output terminals
Add-on Cassette
Securing hole
CC-Link unit
4 Clearwater
The flexible product lineup designed for rapidly responding to user needs provides a high level of satisfaction.
Control Unit
Product Lineup
Input terminals
Control Unit
Relay output
AFPX-C14R
AFPX-C30R
AFPX-C60R
Transistor output
AFPX-C14TD
AFPX-C14T
AFPX-C14PD
AFPX-C14P
AFPX-C30TD
AFPX-C30T
AFPX-C30PD
AFPX-C30P
AFPX-C60TD
AFPX-C60T
AFPX-C60PD
AFPX-C60P
Expansion Unit
Power terminals
Expansion cassette interface cover
Connector for
add-on cassette
I/O status monitor LED
Connector for
expansion unit
Connector
for battery
Potentiometer
AFPX-E16R
AFPX-E16T
AFPX-E16P
Expansion Unit
(Model: Relay output type AFPX-E16R)
AFPX-E30R
Add-on Cassette
Communication cassette
AFPX-COM1
AFPX-COM2
AFPX-COM3
Communication cassette
(RS485/422 selectable 1 ch.)
AFPX-COM4
Communication cassette
(RS485 1 ch + RS232C 1 ch.)
AFPX-E30TD
AFPX-E30T
AFPX-E30PD
AFPX-E30P
AFPX-COM5
AFPX-EFP0
Communication cassette
Application cassette
AFPX-IN8
AFPX-TR8
Output cassette
(NPN transistor 0.3 A, 8 output ch.)
AFPX-AD2
AFPX-PLS
AFPX-MRTC
W
NE
Input terminals
Specifications
FP0-E8X
FP0-E16X
FP0-E8YT
FP0-E8YRS
FP0-E16T
FP0-E16P
FP0-E32T
FP0-E32P
FP0-E8RS
FP0-E16RS
FP0-A21
FP0-A80
FP0-A04V
FP0-A04I
FP0-TC4
FP0-TC8
FP0-IOL
FP0-CCLS
FP0-E32RS*1
FP0-RTD6*1
FP0-DPS2*1
Output terminals
Add-on Cassette
Securing hole
CC-Link unit
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com5
Positioning
Usability
FP-X perfectly fits the need for low cost multi-axis positioning control
in small-scale equipment
Securing 0.5A in every transistor output even when all output ports are ON.
The transistor output type C14 comes with 3-axis while C30/60 comes with 4-axis
pulse output inside the control unit. The multi-axis control, which previously
required a higher-level PLC or additional positioning unit, or two or more PLC units,
can now be achieved with only one FP-X transistor output type unit in a small
space at a low cost. In addition, as this type does not require a pulse I/O cassette
needed for a relay output type, other function expansion cassettes such as
communication or analog input can be attached for more diversified applications.
XY Table + Processing Head
Item
Specification
Pulse Output
C14: 100kHz(CH0,1), 20kHz(CH2)
Max Frequency C30,C60: 100kHz(CH0,1), 20kHz(CH2,3)
Output Type
Function
The transistor output type is not limited by the control capacity of each common
line. Every output port can secure 0.5A even when all output ports are ON for any
basic unit C14, C30, C40 as well as the expansion units E16 and E30 (at 25C)
Sufficient capacity for high-load switching such as LED type signal tower etc.
20kHz x
2 axes
First
axis
80kHz
Second
axis
80kHz
Equipped with a Sampling Trace Function Smart Solution for Program Debugging
(Available from Ver. 2.0 of the transistor type and relay output types)
The sampling trace function enables the user to monitor a change of I/O condition or
data register value in a very short time interval an efficiency tool for debugging a
ladder program.
The shortest sampling interval of the normal time-chart monitor is 10ms with the FPWIN
GR or FPWIN PRO, but monitoring in much shorter intervals is often required during
debugging operations. The sampling trace function enables data accumulation of any
16 contact data and 3 data register values once or several times within a scan time.
Reading out these data through the FPWIN GR or FPWIN PRO enables the user to
confirm an instantaneous change of status by time on the time-chart monitor.
(Normal Time-Chart Monitor)
(Sampling Trace)
Maximum
X-axis
(CH2)
X-axis (CH0)
Using this option, you can monitor the data in FP-X on the
PCWAY through the existing Ethernet, or remotely
upload/download a program.
Model Type
Transistor
Output Type
Dual Phase
Relay Output
Single Phase
Type
Dual Phase
RS232C (COM2)
Computer Link
Ethernet
Communication
PCWAY,
Mode
(1:1 communication) FPWIN GR/PRO
etc.
AFPX-COM5
Ethernet (COM1)
Interface
FP-X
During Halt
100kHz
During Operation
35kHz
During Halt
35kHz
During Operation
15kHz
During Halt
10kHz
10kHz 8ch
During Operation
10kHz
10kHz 8ch
During Halt
5kHz
5kHz 4ch
During Operation
5kHz
5kHz 4ch
PCWAY
FPWIN GR/PRO
FP-X
Ethernet
Computer Link*
General Communication
Ethernet RS232C
FP-X
FP-X
When adding a pulse I/O cassette to the relay output type, two high-speed counter sets can
be added to every cassette. Please refer to the user manual for counter specification.
6 Clearwater
Positioning
Usability
FP-X perfectly fits the need for low cost multi-axis positioning control
in small-scale equipment
Securing 0.5A in every transistor output even when all output ports are ON.
The transistor output type C14 comes with 3-axis while C30/40 comes with 4-axis
pulse output inside the control unit. The multi-axis control, which previously
required a higher-level PLC or additional positioning unit, or two or more PLC units,
can now be achieved with only one FP-X transistor output type unit in a small
space at a low cost. In addition, as this type does not require a pulse I/O cassette
needed for a relay output type, other function expansion cassettes such as
communication or analog input can be attached for more diversified applications.
XY Table + Processing Head
Item
Specification
Pulse Output
C14: 100kHz(CH0,1), 20kHz(CH2)
Max Frequency C30,C60: 100kHz(CH0,1), 20kHz(CH2,3)
Output Type
Function
The transistor output type is not limited by the control capacity of each common
line. Every output port can secure 0.5A even when all output ports are ON for any
basic unit C14, C30, C60 as well as the expansion units E16 and E30 (at 25 C)
Sufficient capacity for high-load switching such as LED type signal tower etc.
20kHz x
2 axes
First
axis
80kHz
Second
axis
80kHz
Equipped with a Sampling Trace Function Smart Solution for Program Debugging
(Available from Ver. 2.0 of the transistor type and relay output types)
The sampling trace function enables the user to monitor a change of I/O condition or
data register value in a very short time interval an efficiency tool for debugging a
ladder program.
The shortest sampling interval of the normal time-chart monitor is 10ms with the FPWIN
GR or FPWIN PRO, but monitoring in much shorter intervals is often required during
debugging operations. The sampling trace function enables data accumulation of any
16 contact data and 3 data register values once or several times within a scan time.
Reading out these data through the FPWIN GR or FPWIN PRO enables the user to
confirm an instantaneous change of status by time on the time-chart monitor.
(Normal Time-Chart Monitor)
(Sampling Trace)
Maximum
X-axis
(CH2)
X-axis (CH0)
Using this option, you can monitor the data in FP-X on the
PCWAY through the existing Ethernet, or remotely
upload/download a program.
Model Type
Transistor
Output Type
Dual Phase
Relay Output
Single Phase
Type
Dual Phase
RS232C (COM2)
Computer Link
Ethernet
Communication
PCWAY,
Mode
(1:1 communication) FPWIN GR/PRO
etc.
AFPX-COM5
Ethernet (COM1)
Interface
FP-X
During Halt
100kHz
During Operation
35kHz
During Halt
35kHz
During Operation
15kHz
During Halt
10kHz
10kHz 8ch
During Operation
10kHz
10kHz 8ch
During Halt
5kHz
5kHz 4ch
During Operation
5kHz
5kHz 4ch
PCWAY
FPWIN GR/PRO
FP-X
Ethernet
Computer Link*
General Communication
Ethernet RS232C
FP-X
FP-X
When adding a pulse I/O cassette to the relay output type, two high-speed counter sets can
be added to every cassette. Please refer to the user manual for counter specification.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com7
Temperature Control
Touch Panel
Parameter setup
Target value
Control code
PID control elements
Start bit ON
Auto-tuning end
Program
Heater
Only a
single
command
PWM output
frequency setup
R0
Y0
WX1,
DT0,
16k
FP0
10k
10k
20k
30k
steps
FP-X
0.32 sec
0.9 sec
FP0
ms (measured time)
DT100
PWM output
C14
PWM output
FP-X
C14
SSR
32k
100,000 I/O comment items, 5,000 lines of line-space comments, 5,000 lines of remark
comments - All comments are stored in the FP-X simultaneously with the program.
C30/C60
C30, C60
Separate memory areas reserved for program memory and comments do not cause a
reduction of program capacity when comments are entered.
Auto-tuning setup
Constant Temperature
Program capacity
FP-X
1.0 sec
0.5
Output address
300
(Up to 382 points possible by using FP0 expansion units and add-on cassettes)
C60
E30
E30
E30
Multiple temperature
controllers
Easy unification of
data management
Max. 8 units
FP-X
T/C
T/C
T/C
T/C
C60
E16
E16
C60
E30
NG
OK
High-speed PID
control
PI-D mode
Target value
Target
value
Target
value
C60
I-PD mode
Rapid acceleration
Smooth startup
Time
Time
E30
E30
Overshoot suppression
8 Clearwater
E16
*1 Derivative type
*2 Proportional-derivative type
Modbus-RTU
Time
Temperature Control
Touch Panel
Parameter setup
Target value
Control code
PID control elements
Start bit ON
Auto-tuning end
Program
Heater
Only a
single
command
PWM output
frequency setup
R0
Y0
WX1,
DT0,
16k
FP0
10k
10k
20k
30k
steps
FP-X
0.32 sec
0.9 sec
FP0
ms (measured time)
DT100
PWM output
C14
PWM output
FP-X
C14
SSR
32k
100,000 I/O comment items, 5,000 lines of line-space comments, 5,000 lines of remark
comments - All comments are stored in the FP-X simultaneously with the program.
C30/C60
C30, C60
Separate memory areas reserved for program memory and comments do not cause a
reduction of program capacity when comments are entered.
Auto-tuning setup
Constant Temperature
Program capacity
FP-X
1.0 sec
0.5
Output address
300
(Up to 382 points possible by using FP0 expansion units and add-on cassettes)
C60
E30
E30
E30
Multiple temperature
controllers
Easy unification of
data management
Max. 8 units
FP-X
T/C
T/C
T/C
T/C
C60
E16
E16
C60
E30
NG
OK
High-speed PID
control
PI-D mode
Target value
Target
value
Target
value
C60
I-PD mode
Rapid acceleration
Smooth startup
Time
Time
E30
E30
Overshoot suppression
E16
*1 Derivative type
*2 Proportional-derivative type
Modbus-RTU
Time
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com9
Expansion
Network
"Require slightly more functions", "Want to add functions to the existing equipment"
Different types of equipment need to be linked FP-X flexibly meet such requirements.
The add-on cassette can be mounted onto the control unit easily.
Up to 2 cassettes on C14 or up to 3 cassettes on C30/C60 can be mounted.
Only communication cassette can be double-stacked upper side. (Communication cassette should be only one totally.)
Note) Please refer to the manual for the number of mountable units and position.
Add-on Cassette
DC input
AFPX-IN8
Application Cassette
Analog input
AFPX-AD2
Master memory
AFPX-MPTC
Communication
Cassette
NE
PC
RS232C
AFPX-COM3
RS485/RS422 selectable
AFPX-COM4
RS485 + RS232C*1
AFPX-COM5
1 ch. each
Easily removable
(Two screws to secure the unit)
Item
Specifications
E30
Modbus* Compatibility
Product number
Simple setting of the number of linked units, linked relays, and starting
Transmission speed
115.2 kbps
area address of the own station by using FPWIN GR/Pro allows sharing
Transmission distance
1200 m
of contact information and data without programming.
128 words (data register), 64 words (contacts)
Shared data
The transfer rate of 115.2 kbps, the highest rate for a compact model.
Communication method Floating master
A transfer distance of 1200 m, the longest distance for a compact model.
FP-X and FP allow a change of the station number by programming
(SYS instruction).
16 stations, 115.2 kbps, 1200 m
RS485
Twisted-pair cable
Specifications
16 stations
* Only one expansion FP0 adapter unit can be attached to a control unit.
Up to 7 FP-X expansion units can be used when the expansion FP0 adapter is attached.
Max. 96 points
Compatible with both the master and slave of the Modbus* RTU, the world's de-facto standard
Great performance is expected for air-conditioning, temperature controls etc.
* Protocol developed by the Modicon Inc. of the United States
Specifications
FP0-A21
FP0-A80
FP0-A04V
FP0-A04I
FP0-TC4
FP0-TC8
FP0-IOL
FP0-CCL
Inverter
10Clearwater
Modbus-RTU (115.2kbps,1200m)
RS485
1 ch.
All control units can be expanded by up to 3 FP0 expansion units via an adapter.
Applications can be expanded by using [Transistor outputs], [Analog input/outputs],
[Thermocouple input] and [I/O link (network)].
When further expansion or functions are required, use the existing FP0 expansion unit.
FP0-E16RS
RS232C
Number of stations
1st ch.
PLC Link
2 ch.
E30
Always used
(Port No. COM1)
FP-e (PLC)
Temperature controller etc.
FP0-E8RS
1 ch.
FP0-E32T
Always used
GT11
AFPX-COM2
Product number
FP0-E8X
FP0-E16X
FP0-E8YT
FP0-E8YRS
FP0-E16YT
Communication Port
RS232C tool port
USB
RS232C
C60
Communication cassette
AFPX-COM1
*1
Eco-POWER METER
KW4M
Temperature
Controller
KT4H
*The RS232C tool port can be used as a general-purpose serial communication port.
RS485
Specifications
RS232C
Communication
cassette
The
PLC
FP-e
FP
Master/
slave
Master/
slave
Master/
slave
Master/
slave
Multi-master link of up
to 99 units is possible.
11
Expansion
Network
"Require slightly more functions", "Want to add functions to the existing equipment"
Different types of equipment need to be linked FP-X flexibly meet such requirements.
The add-on cassette can be mounted onto the control unit easily.
Up to 2 cassettes on C14 or up to 3 cassettes on C30/C60 can be mounted.
Only communication cassette can be double-stacked upper side. (Communication cassette should be only one totally.)
Note) Please refer to the manual for the number of mountable units and position.
Add-on Cassette
DC input
AFPX-IN8
Application Cassette
Analog input
AFPX-AD2
Master memory
AFPX-MPTC
Communication
Cassette
NE
RS232C
AFPX-COM2
RS232C
AFPX-COM3
RS485/RS422 selectable
AFPX-COM4
RS485 + RS232C*1
AFPX-COM5
PC
1 ch.
1 ch. each
Easily removable
(Two screws to secure the unit)
Item
Specifications
Specifications
Product number
16 stations
Simple setting of the number of linked units, linked relays, and starting
Transmission speed
115.2 kbps
area address of the own station by using FPWIN GR/Pro allows sharing
Transmission distance
1200 m
of contact information and data without programming.
128 words (data register), 64 words (contacts)
Shared data
The transfer rate of 115.2 kbps, the highest rate for a compact model.
Communication method Floating master
A transfer distance of 1200 m, the longest distance for a compact model.
FP-X and FP allow a change of the station number by programming
(SYS instruction).
16 stations, 115.2 kbps, 1200 m
RS485
Twisted-pair cable
Modbus* Compatibility
Max. 96 points
Compatible with both the master and slave of the Modbus* RTU, the world's de-facto standard
Great performance is expected for air-conditioning, temperature controls etc.
* Protocol developed by the Modicon Inc. of the United States
Specifications
FP0-A21
FP0-A80
FP0-A04V
FP0-A04I
FP0-TC4
FP0-TC8
FP0-IOL
FP0-CCL
10
E30
1st ch.
Modbus-RTU (115.2kbps,1200m)
RS485
Number of stations
E30
Always used
(Port No. COM1)
PLC Link
2 ch.
FP0-E16RS
GT11
* Only one expansion FP0 adapter unit can be attached to a control unit.
Up to 7 FP-X expansion units can be used when the expansion FP0 adapter is attached.
FP0-E8RS
RS232C
1 ch.
All control units can be expanded by up to 3 FP0 expansion units via an adapter.
Applications can be expanded by using [Transistor outputs], [Analog input/outputs],
[Thermocouple input] and [I/O link (network)].
When further expansion or functions are required, use the existing FP0 expansion unit.
FP0-E32T
Always used
USB
Product number
FP0-E8X
FP0-E16X
FP0-E8YT
FP0-E8YRS
FP0-E16YT
Communication Port
RS232C tool port
Communication cassette
C60
FP-e (PLC)
Temperature controller etc.
AFPX-COM1
*1
Eco-POWER METER
KW4M
Temperature
Controller
KT4H
*The RS232C tool port can be used as a general-purpose serial communication port.
RS485
Specifications
RS232C
Communication
cassette
The
Inverter
PLC
FP-e
FP
Master/
slave
Master/
slave
Master/
slave
Master/
slave
Multi-master link of up
to 99 units is possible.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com11
Program protection
Programming
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Protected
Protected
Master memory
Items possible
during an uploadprohibited condition
Forced input/output
(Original program is required)
Ladder monitor
(Original program is required)
Rewrite during RUN mode
(Original program is required)
Password protection
Features
1. Easy field operations not requiring the use of a mouse for data
entry, search, writing, monitoring and timer changes, all carried
out only from the keyboard.
OS
At least 40 MB
CPU
Onboard memory
Screen resolution
Display colors
Applicable PLC
FP-X/FP-e/FP0/FP/FP2/FP2SH
Compatible FP-X
version
Tool bar
Adaptability
High versatility and rich functionality provides peace of mind and flexibility.
Function bar
Program display
Before
PC
The master memory makes a program transfer easy and a real-time clock is equipped also
The built-in 1 MB flash-ROM can store a 32-kstep program as well as the
comments and FPWIN Pro source file.
Program update in a remote location is easy by simply sending master
memory for local installation.
As the master memory stores the password information, password protection can be
applied for program transmission. Similarly, upload prohibition/permission can be setup.
The built-in real-time clock enables periodical repeated control and
periodical data logging.
Master memory
To the field
operation
Program
transfer
FPWIN GR/Pro
FP-X
Program
transfer
The programs and comments are stored in flash ROM, requiring no backup batteries.
A backup battery is provided for data and real-time clock (AFPX-BATT)
One battery for C14, two for C30 and three for C60 can be attached. A twoBattery
battery installation can operate for a long time (10 years or more) without
holder
maintenance. (Real-time clock doesn't work without a battery.)
FP-X
Flash-ROM
* The limitation in a flash ROM designates the number of rewrites to be 10,000, or the feasible number to be approx 30,000. However,
rewriting every second will generate a memory failure within a few hours.
Writing
Accompanying Tools
Text Compiler
Data Editor
This software for the PC is for reading and writing data
stored in the memory of FP Series main unit or on an IC
card. If a large data table is required in a PLC, the data
can be created and edited on a PC and then dowmload
to the PLC.
Modem connection
Connector
Backup battery
for FP-X
(AFPX-BATT)
Text command
input mode
12Clearwater
Status display
AFPX-C30/C60
PC
Wizard function
This software is for importing and
exporting programs created in text
format to and from FPWIN GR.
Programs created on the PLC of
another company can be edited as
text and then be transferred to the
FP Series without difficulty.
13
Program protection
Programming
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Protected
Protected
Master memory
Items possible
during an uploadprohibited condition
Forced input/output
(Original program is required)
Ladder monitor
(Original program is required)
Rewrite during RUN mode
(Original program is required)
Password protection
Features
1. Easy field operations not requiring the use of a mouse for data
entry, search, writing, monitoring and timer changes, all carried
out only from the keyboard.
OS
At least 40 MB
CPU
Onboard memory
Screen resolution
Display colors
Applicable PLC
FP-X/FP-e/FP0/FP/FP2/FP2SH
Compatible FP-X
version
Tool bar
Adaptability
High versatility and rich functionality provides peace of mind and flexibility.
Function bar
Program display
Before
PC
The master memory makes a program transfer easy and a real-time clock is equipped also
The built-in 1 MB flash-ROM can store a 32-kstep program as well as the
comments and FPWIN Pro source file.
Program update in a remote location is easy by simply sending master
memory for local installation.
As the master memory stores the password information, password protection can be
applied for program transmission. Similarly, upload prohibition/permission can be setup.
The built-in real-time clock enables periodical repeated control and
periodical data logging.
Master memory
To the field
operation
Program
transfer
FPWIN GR/Pro
FP-X
Program
transfer
The programs and comments are stored in flash ROM, requiring no backup batteries.
A backup battery is provided for data and real-time clock (AFPX-BATT)
One battery for C14, two for C30 and three for C60 can be attached. A twoBattery
battery installation can operate for a long time (10 years or more) without
holder
maintenance. (Real-time clock doesn't work without a battery.)
FP-X
Flash-ROM
* The limitation in a flash ROM designates the number of rewrites to be 10,000, or the feasible number to be approx 30,000. However,
rewriting every second will generate a memory failure within a few hours.
Writing
Accompanying Tools
Text Compiler
Data Editor
This software for the PC is for reading and writing data
stored in the memory of FP Series main unit or on an IC
card. If a large data table is required in a PLC, the data
can be created and edited on a PC and then dowmload
to the PLC.
Modem connection
Connector
Backup battery
for FP-X
(AFPX-BATT)
Text command
input mode
12
Status display
AFPX-C30/C60
PC
Wizard function
This software is for importing and
exporting programs created in text
format to and from FPWIN GR.
Programs created on the PLC of
another company can be edited as
text and then be transferred to the
FP Series without difficulty.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com13
Programming
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Product name
Relay output
Features
3. Keep know-how from getting out
Transistor output
Person A (designer)
Programming time can be greatly reduced by the easy ability to split and
then integrate programming for each function and process.
Main program
(SFC)
Designer A
(SFC)
Positioning program
(ST)
Designer B
(ST)
Completed
program
Communications
program
(ST)
All blocks
Block 1
Block 2
Person C (operator)
100 to 240V AC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
Product name
Only block 1
Block 2
Block 1 Low
Block 2
Block 3
Block 4 High
Block 4
Completed
program
100 to 240V AC
24V DC
100 to 240V AC
Operational Environment
OS
At least 100 MB
CPU
Onboard memory
Screen resolution
Display colors
Applicable PLC
FP-X/FP-e/FP0/FP/FP1/FP-M/FP2/FP2SH/FP3/FP10SH
Compatible FP-X
version
Communications program
Malfunction handling
program
Position
Operation
Function
Modem
Connection
Function
Communications program
Malfunction handling
program
Main program
Initialliton
Setting
Process
AFPX-C30R
AFPX-C60R
AFPX-C14TD
AFPX-C14T
AFPX-C14PD
AFPX-C14P
AFPX-C30TD
AFPX-C30T
AFPX-C30PD
AFPX-C30P
AFPX-C60TD
AFPX-C60T
AFPX-C60PD
AFPX-C60P
Specifications
8-point input of 24 V DC, 8-point relay output of 2 A
Remarks; Two or more E16R can't be connected serially because it can't supply the power to other units. With an 8cm extension cable
16-point input of 24 V DC, 14-point relay output of 2 A
Remarks; Possible to connect up to 8 units including E16R, EFP0. With an 8cm extension cable
Part number
AFPX-E16R
AFPX-E30R
AFPX-E16T
AFPX-E16P
AFPX-E30TD
AFPX-E30T
24V DC
AFPX-E30PD
100 to 240V AC
AFPX-E30P
AFPX-EFP0
24V DC
Positioning program
Part number
AFPX-C14R
Parts library
Designer D
(ladder)
Specifications
8-point input of 24 V DC, 6-point output of 2 A relay
Program capacity 16 ksteps, 2-point potentiometer
16-point input of 24 V DC, 14-point output of 2 A relay
Program capacity 32 ksteps, 2-point potentiometer, USB port
32-point input of 24 V DC, 28-point output of 2 A relay
Program capacity 32 ksteps, 4-point potentiometer, USB port
Power supply
Designer C
(ST)
Malfunction handling
program
(ladder)
Power supply
100 to 240V AC
FP-X C14PD
Control unit
FP-X C14P
Control unit
FP-X C30TD
Control unit
FP-X C30T
Control unit
FP-X C30PD
Control unit
FP-X C30P
Control unit
FP-X C60TD
Control unit
FP-X C60T
Control unit
FP-X C60PD
Control unit
FP-X C60P
Control unit
Transistor output
FP-X C14R
Control unit
FP-X C30R
Control unit
FP-X C60R
Control unit
FP-X C14TD
Control unit
FP-X C14T
Control unit
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product name
Specifications
Part number
AFPX-COM1
AFPX-COM2
AFPX-COM3
AFPX-COM4
AFPX-COM5
AFPX-IN8
AFPX-TR8
AFPX-TR6P
AFPX-AD2
AFPX-PLS
AFPX-MRTC
Specifications
Part number
AFPX-BATT
AFPX-EC08
AFPX-EC30
AFPX-EC80
AFPX-TAN1
Programming
Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies.
Product name
Relay output
Features
3. Keep know-how from getting out
Transistor output
Person A (designer)
Programming time can be greatly reduced by the easy ability to split and
then integrate programming for each function and process.
Main program
(SFC)
Designer A
(SFC)
Positioning program
(ST)
Designer B
(ST)
Completed
program
Communications
program
(ST)
All blocks
Block 1
Block 2
Person C (operator)
100 to 240V AC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
24V DC
100 to 240V AC
Product name
Only block 1
Block 2
Block 1 Low
Block 2
Block 3
Block 4 High
Block 4
Completed
program
100 to 240V AC
24V DC
100 to 240V AC
Operational Environment
OS
At least 100 MB
CPU
Onboard memory
Screen resolution
Display colors
Applicable PLC
FP-X/FP-e/FP0/FP/FP1/FP-M/FP2/FP2SH/FP3/FP10SH
Compatible FP-X
version
Communications program
Malfunction handling
program
Position
Operation
Function
Modem
Connection
Function
Communications program
Malfunction handling
program
Main program
Initialliton
Setting
Process
AFPX-C30R
AFPX-C60R
AFPX-C14TD
AFPX-C14T
AFPX-C14PD
AFPX-C14P
AFPX-C30TD
AFPX-C30T
AFPX-C30PD
AFPX-C30P
AFPX-C60TD
AFPX-C60T
AFPX-C60PD
AFPX-C60P
Specifications
8-point input of 24 V DC, 8-point relay output of 2 A
Remarks; Two or more E16R can't be connected serially because it can't supply the power to other units. With an 8cm extension cable
16-point input of 24 V DC, 14-point relay output of 2 A
Remarks; Possible to connect up to 8 units including E16R, EFP0. With an 8cm extension cable
Part number
AFPX-E16R
AFPX-E30R
AFPX-E16T
AFPX-E16P
AFPX-E30TD
AFPX-E30T
24V DC
AFPX-E30PD
100 to 240V AC
AFPX-E30P
AFPX-EFP0
24V DC
Positioning program
Part number
AFPX-C14R
Parts library
Designer D
(ladder)
Specifications
8-point input of 24 V DC, 6-point output of 2 A relay
Program capacity 16 ksteps, 2-point potentiometer
16-point input of 24 V DC, 14-point output of 2 A relay
Program capacity 32 ksteps, 2-point potentiometer, USB port
32-point input of 24 V DC, 28-point output of 2 A relay
Program capacity 32 ksteps, 4-point potentiometer, USB port
Power supply
Designer C
(ST)
Malfunction handling
program
(ladder)
Power supply
100 to 240V AC
FP-X C14PD
Control unit
FP-X C14P
Control unit
FP-X C30TD
Control unit
FP-X C30T
Control unit
FP-X C30PD
Control unit
FP-X C30P
Control unit
FP-X C60TD
Control unit
FP-X C60T
Control unit
FP-X C60PD
Control unit
FP-X C60P
Control unit
Transistor output
FP-X C14R
Control unit
FP-X C30R
Control unit
FP-X C60R
Control unit
FP-X C14TD
Control unit
FP-X C14T
Control unit
Product name
Specifications
Part number
AFPX-COM1
AFPX-COM2
AFPX-COM3
AFPX-COM4
AFPX-COM5
AFPX-IN8
AFPX-TR8
AFPX-TR6P
AFPX-AD2
AFPX-PLS
AFPX-MRTC
Specifications
Part number
AFPX-BATT
AFPX-EC08
AFPX-EC30
AFPX-EC80
AFPX-TAN1
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Related Products
FP Memory Loader
FP0 Expansion Units
Product name
Specifications
Number of I/O points
8
8
Input: 8
Input: 4
Output: 4
Input
Output
Connection type
24 V DC Sink/Source (common)
MIL connector
Terminal block
Molex connecter
Terminal block
24 V DC Sink/Source (common)
Relay output: 2 A
Output: 8
24 V DC
Output: 8
16
Input: 16
16
Input: 8
Output: 8
Input: 8
Output: 8
16
32
16
FP0 E16 Expansion Unit
Power supply
voltage
24 V DC
FP Web-Server Unit
Product name
24 V DC Sink/Source (common)
Relay output: 2 A
Transistor output:
NPN 0.1 A
24 V DC
24 V DC Sink/Source (common)
Relay output: 2 A
Product number
Part number
FP0-E8X
FP0-E8RS
FP0-E8RM
FP0-E8YRS
AFP03003
AFP03023
AFP03013
AFP03020
FP0-E8YT
AFP03040
MIL connector
Part number
FP Web-Server unit
AFP8671
AFW10011
AFW10031
Product name
AFW10401
AFW1031*
AFW1033
FP0-E16RS
FP0-E16RM
AFP03323
AFP03313
Product name
Control CommX IBM printer port
AFW20011
AFW20031
MIL connector
FP0-E16T
AFP03343
Output: 16
MIL connector
FP0-E16YT
AFP03340
Input: 16
Output: 16
24 V DC Sink/Source (common)
Transistor output:
NPN 0.1 A
Transistor output:
NPN 0.1 A
MIL connector
FP0-E32T
AFP03543
Notes: 1) The relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type needs no power cable.)
2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm wide screwdriver.
Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS 0. 4 2.5 mm) or equivalent.
3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins).
Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent.
4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable.
Key Unit
AFP03303
Transistor output:
NPN 0.1 A
AFP0610
AFPS30510
Part number
FP0-E16X
24 V DC Sink/Source (common)
Part number
AFP8670
MIL connector
Terminal block
Molex connecter
Product name
Part number
Part number
Specifications
Specifications
K, J, T, R thermocouple, Resolution: 0.1 C
K, J, T, R thermocouple, Resolution: 0.1 C
<Input specifications>
Number of channels:
Input range:
<Output specifications>
Number of channels:
Output range:
<Input specifications>
Number of channels:
Input range:
<Output specifications>
Number of channels:
Output range:
Product number
FP0-TC4
FP0-TC8
2 channels
0 to 5 V, 10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
1 channel
10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
8 channels
0 to 5, 10 to +10 V, 100 to 100 mV (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
4 channels
10 to +10 V (Resolution: 1/4000)
4 to 20 mA (Resolution: 1/4000)
Part number
AFP0420
AFP0421
AFP0480
FP0-A80
AFP0401
FP0-A04V
AFP04121
FP0-A04I
AFP04123
Power supply
Product number
voltage
Specifications
This unit is for making the FP0 function as a slave station of the CC-Link.
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.
This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system).
Part number
Breakdown voltage
Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the FP0 catalog
or to the CC-Link Unit manual.
24 V DC
FP0-CCLS
AFP07943
24 V DC
FP0-IOL
AFP0732
Insulation resistance
Type
Part number
FP-X
FP
FP0
.
FP-e
A
A
A
A
A
A
AFPS10520
AFPS11520
AFPS10520R
AFPS10820
AFPS10820R
AFPS10920
Applicable PLC
FP0
FP1*
FP2
10k
A
A
A
A
A
N/A
FP2SH FP-M*
FP3*
.
FP10SH
A
N/A
A
A
A
N/A
FPWIN Pro
for Windows
Type
English: Full type
English: Small type
Part number
CD-ROM for Windows
CD-ROM for Windows
AFPS50550
AFPS51550
FP-X
FP
FP0
.
FP-e
A
A
A
A
A
A
Applicable PLC
FP0
FP1*
FP2
10k
A
A
A
A
A
N/A
A
N/A
A
A
FP3*
.
FP10SH
A
N/A
RS232C type
5 V DC
RS422/RS485 type
STN monochrome LCD
RS232C type
24 V DC
RS422/RS485 type
RS232C type
24 V DC
RS422/RS485 type
RS232C type
STN color LCD
Control unit
24 V DC
RS422/RS485 type
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Silver
Black
Silver
Part number
Current consumption
Weight
AFPX-C14
26 W or less *2
AFPX-C30
52 W or less *2
AFPX-C60
64 W or less *2
AFPX-E16
8 W or less *2
AFPX-E30
42 W or less *2
AFPX-EFP0
0.24 W or less *3
Approx. 65 g
Part number
AFPX-COM1
2 W or less *2
Approx. 20 g
AIGT0030B1
AIGT0030H1
AIGT0032B1
AIGT0032H1
AIGT0030B
AIGT0030H
AIGT0032B
AIGT0032H
AIGT2030B
AIGT2030H
AIGT2032B
AIGT2032H
AIGT2230B
AIGT2230H
AIGT2232B
AIGT2232H
AFPX-COM2
2 W or less *2
Approx. 20 g
AFPX-COM3
2 W or less *2
Approx. 20 g
AFPX-COM4
2 W or less *2
Approx. 20 g
AFPX-COM5
2 W or less *2
Approx. 20 g
AFPX-AD2
2 W or less *2
Approx. 25 g
AFPX-IN8
1 W or less *2
Approx. 25 g
AFPX-TR8
1 W or less *2
Approx. 25 g
AFPX-TR6P
1 W or less *2
Approx. 25 g
AFPX-PLS
2 W or less *2
Approx. 25 g
AFPX-MRTC
2 W or less *2
Approx. 20 g
Product name
1500 V [P-P] pulse width 50 ns, 1 s (AC power), 500 V [P-P] pulse width 50 ns, 1 s (DC power) (per noise simulator method) (power terminals)
No corrosive gas and no excessive dust
Conforming to EN61131-2
2
II
*1 Cutoff current 5 mA
Product name
FP2SH FP-M*
Vibration resistance
Shock resistance
Noise immunity
Operating condition
EC Directive Compliance Standard
Level of contamination
Over-voltage category
Description
Item
Rated voltage
Operating voltage range
Rush current
FP0-A21
1. General Specifications
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
*3 Power consumption by the DC power supply connected to the expansion FP0 adapter
Related Products
FP Memory Loader
FP0 Expansion Units
Product name
Specifications
Number of I/O points
8
8
Input: 8
Input: 4
Output: 4
Input
Output
Connection type
24 V DC Sink/Source (common)
MIL connector
Terminal block
Molex connecter
Terminal block
24 V DC Sink/Source (common)
Relay output: 2 A
Output: 8
24 V DC
Output: 8
16
Input: 16
16
Input: 8
Output: 8
Input: 8
Output: 8
16
32
16
FP0 E16 Expansion Unit
Power supply
voltage
24 V DC
FP Web-Server Unit
Product name
24 V DC Sink/Source (common)
Relay output: 2 A
Transistor output:
NPN 0.1 A
24 V DC
24 V DC Sink/Source (common)
Relay output: 2 A
Product number
Part number
FP0-E8X
FP0-E8RS
FP0-E8RM
FP0-E8YRS
AFP03003
AFP03023
AFP03013
AFP03020
FP0-E8YT
AFP03040
MIL connector
Part number
FP Web-Server unit
AFP8671
AFW10011
AFW10031
Product name
AFW10401
AFW1031*
AFW1033
FP0-E16RS
FP0-E16RM
AFP03323
AFP03313
Product name
Control CommX IBM printer port
AFW20011
AFW20031
MIL connector
FP0-E16T
AFP03343
Output: 16
MIL connector
FP0-E16YT
AFP03340
Input: 16
Output: 16
24 V DC Sink/Source (common)
Transistor output:
NPN 0.1 A
Transistor output:
NPN 0.1 A
MIL connector
FP0-E32T
AFP03543
Notes: 1) The relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type needs no power cable.)
2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm wide screwdriver.
Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS 0. 4 2.5 mm) or equivalent.
3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins).
Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent.
4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable.
Key Unit
AFP03303
Transistor output:
NPN 0.1 A
AFP0610
AFPS30510
Part number
FP0-E16X
24 V DC Sink/Source (common)
Part number
AFP8670
MIL connector
Terminal block
Molex connecter
Product name
Part number
Part number
Specifications
Specifications
K, J, T, R thermocouple, Resolution: 0.1 C
K, J, T, R thermocouple, Resolution: 0.1 C
<Input specifications>
Number of channels:
Input range:
<Output specifications>
Number of channels:
Output range:
<Input specifications>
Number of channels:
Input range:
<Output specifications>
Number of channels:
Output range:
Product number
FP0-TC4
FP0-TC8
2 channels
0 to 5 V, 10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
1 channel
10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
8 channels
0 to 5, 10 to +10 V, 100 to 100 mV (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
4 channels
10 to +10 V (Resolution: 1/4000)
4 to 20 mA (Resolution: 1/4000)
Part number
AFP0420
AFP0421
AFP0480
FP0-A80
AFP0401
FP0-A04V
AFP04121
FP0-A04I
AFP04123
Power supply
Product number
voltage
Specifications
This unit is for making the FP0 function as a slave station of the CC-Link.
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.
This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system).
Part number
Breakdown voltage
Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the FP0 catalog
or to the CC-Link Unit manual.
24 V DC
FP0-CCLS
AFP07943
24 V DC
FP0-IOL
AFP0732
Insulation resistance
Type
Part number
FP-X
FP
FP0
.
FP-e
A
A
A
A
A
A
AFPS10520
AFPS11520
AFPS10520R
AFPS10820
AFPS10820R
AFPS10920
Applicable PLC
FP0
FP1*
FP2
10k
A
A
A
A
A
N/A
FP2SH FP-M*
FP3*
.
FP10SH
A
N/A
A
A
A
N/A
FPWIN Pro
for Windows
Type
English: Full type
English: Small type
Part number
CD-ROM for Windows
CD-ROM for Windows
AFPS50550
AFPS51550
FP-X
FP
FP0
.
FP-e
A
A
A
A
A
A
Applicable PLC
FP0
FP1*
FP2
10k
A
A
A
A
A
N/A
A
N/A
A
A
RS232C type
5 V DC
RS422/RS485 type
STN monochrome LCD
RS232C type
24 V DC
RS422/RS485 type
RS232C type
24 V DC
RS422/RS485 type
RS232C type
STN color LCD
FP3*
.
FP10SH
A
N/A
Control unit
24 V DC
RS422/RS485 type
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Ash gry
Black
Silver
Black
Silver
Part number
Current consumption
Weight
AFPX-C14
26 W or less *2
AFPX-C30
52 W or less *2
AFPX-C60
64 W or less *2
AFPX-E16
8 W or less *2
AFPX-E30
42 W or less *2
AFPX-EFP0
0.24 W or less *3
Approx. 65 g
Part number
AFPX-COM1
2 W or less *2
Approx. 20 g
AIGT0030B1
AIGT0030H1
AIGT0032B1
AIGT0032H1
AIGT0030B
AIGT0030H
AIGT0032B
AIGT0032H
AIGT2030B
AIGT2030H
AIGT2032B
AIGT2032H
AIGT2230B
AIGT2230H
AIGT2232B
AIGT2232H
AFPX-COM2
2 W or less *2
Approx. 20 g
AFPX-COM3
2 W or less *2
Approx. 20 g
AFPX-COM4
2 W or less *2
Approx. 20 g
AFPX-COM5
2 W or less *2
Approx. 20 g
AFPX-AD2
2 W or less *2
Approx. 25 g
AFPX-IN8
1 W or less *2
Approx. 25 g
AFPX-TR8
1 W or less *2
Approx. 25 g
AFPX-TR6P
1 W or less *2
Approx. 25 g
AFPX-PLS
2 W or less *2
Approx. 25 g
AFPX-MRTC
2 W or less *2
Approx. 20 g
Product name
1500 V [P-P] pulse width 50 ns, 1 s (AC power), 500 V [P-P] pulse width 50 ns, 1 s (DC power) (per noise simulator method) (power terminals)
No corrosive gas and no excessive dust
Conforming to EN61131-2
2
II
*1 Cutoff current 5 mA
Product name
FP2SH FP-M*
Vibration resistance
Shock resistance
Noise immunity
Operating condition
EC Directive Compliance Standard
Level of contamination
Over-voltage category
Description
Item
Rated voltage
Operating voltage range
Rush current
FP0-A21
1. General Specifications
*3 Power consumption by the DC power supply connected to the expansion FP0 adapter
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Specifications
Specifications
4. Input Specifications (Control unit, expansion unit)
3. Controls Specifications
Item
Program method
Control method
Program memory
Program capacity
111
Applied instructions
216
1760 points *4
1760 points *4
4096 points
192 points
2048 points
24 V DC
21.6 to 26.4 V DC
19.2 V/3 mA
2.4 V/1 mA
Input impedance
Control unit X0 to X7
256 words
374 words
Response OFF ON
14 words
time
256 points
256 labels
Number of differentiations
Up to program capacity
Number of stepladders
1000 stages
Number of subroutines
500 subroutines
High-speed counter *5
ON OFF
0.5 ms to 30 s
Possible
Constant scan
Item
Description
Output type
1a contact
Life time
Counter 16 points (1008 to 1023), Internal relay 128 points (R2470 to R255F), Data register 55 words
Approx. 8 ms
Mechanical
Electrical
None
Item
Description
Insulation method
Photocoupler
Open collector
Output type
Rated loadf voltage
Comment storage
Max 16 units, link relay 1024 points, link register 128 words (No data transfer or remote programming)
*4
*5
*6
*7
*8
Capable
LED display
Self-diagnosis function
100,000 operations or more (Operation frequency 20 times/min at the rated control capacity)
Operating indicator
(More than two batteries can be installed in C30 and C60. In this case, the battery life is extended several times)
Password
Approx. 10 ms
ON OFF
Surge absorber
The memory allocated in the storage area by the system register (only when a battery is installed) *8
Battery backup
4 points/common
OFF ON
LED display
Real-time clock
Same as above
Periodical interrupt
Potentiometer
Control unit X4 to X7
135 s or less: Nominal input
50 s or less: High-speed counter, pulse catch, interruption input setting*1
Control unit X8 and after, expansion unit
0.6 ms or less
Operating indicator
Pulse I/O cassette (AFPX-PLS) for relay output type: One unit (one axis) 100 kHz, or two units (two axes) 80 kHz
Control unit X0 to X3
135 s or less: Nominal input
5 s or less: High-speed counter, pulse catch, interruption input setting*1
Pulse I/O cassette (AFPX-PLS) for relay output type: single-phase 2 ch (80 kHz x 2 ch)
Pulse output *6
0.6 ms or less
18Clearwater
Transistor output
Photo-coupler
Flash ROM
backup *9
Relay output
Insulation method
Total 1024 points: timer capable of counting (1 ms, 10 ms, 100 ms, 1 s) x 32767
Timer/counter (T/C)
Description
Item
Specifications
OFF ON
ON OFF
Surge absorber
Zener diode
Operating indicator
LED display
*2 Please refer to the user manual for Y0 to Y7 of the transistor output type.
19
Specifications
Specifications
4. Input Specifications (Control unit, expansion unit)
3. Controls Specifications
Item
Program method
Control method
Program memory
Program capacity
111
Applied instructions
216
1760 points *4
1760 points *4
4096 points
192 points
2048 points
21.6 to 26.4 V DC
19.2 V/3 mA
2.4 V/1 mA
Input impedance
Control unit X0 to X7
374 words
Response OFF ON
14 words
time
256 points
256 labels
Number of differentiations
Up to program capacity
Number of stepladders
1000 stages
Number of subroutines
500 subroutines
High-speed counter *5
ON OFF
0.5 ms to 30 s
Possible
Constant scan
Item
Description
Output type
1a contact
Life time
Battery backup
Counter 16 points (1008 to 1023), Internal relay 128 points (R2470 to R255F), Data register 55 words
Approx. 8 ms
Mechanical
Electrical
None
Item
Description
Insulation method
Photocoupler
Open collector
Output type
Max 16 units, link relay 1024 points, link register 128 words (No data transfer or remote programming)
Comment storage
Capable
LED display
Self-diagnosis function
100,000 operations or more (Operation frequency 20 times/min at the rated control capacity)
Operating indicator
(More than two batteries can be installed in C30 and C60. In this case, the battery life is extended several times)
Password
Approx. 10 ms
ON OFF
Surge absorber
The memory allocated in the storage area by the system register (only when a battery is installed) *8
Before installing AFPX-MRTC
4 points/common
OFF ON
LED display
Real-time clock
Same as above
Periodical interrupt
Potentiometer
Control unit X4 to X7
135 s or less: Nominal input
50 s or less: High-speed counter, pulse catch, interruption input setting*1
Control unit X8 and after, expansion unit
0.6 ms or less
Operating indicator
Pulse I/O cassette (AFPX-PLS) for relay output type: One unit (one axis) 100 kHz, or two units (two axes) 80 kHz
Control unit X0 to X3
135 s or less: Nominal input
5 s or less: High-speed counter, pulse catch, interruption input setting*1
Pulse I/O cassette (AFPX-PLS) for relay output type: single-phase 2 ch (80 kHz x 2 ch)
Pulse output *6
0.6 ms or less
18
24 V DC
*4
*5
*6
*7
*8
Transistor output
Photo-coupler
Flash ROM
backup *9
Relay output
Insulation method
Total 1024 points: timer capable of counting (1 ms, 10 ms, 100 ms, 1 s) x 32767
Timer/counter (T/C)
Description
Item
Specifications
OFF ON
ON OFF
Surge absorber
Zener diode
Operating indicator
LED display
*2 Please refer to the user manual for Y0 to Y7 of the transistor output type.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com19
AFPX-C14 (The same dimensions apply to the expansion I/O unit AFPX-E16)
COM
X0
X2
X5
X4
X7
X6
PROG. ERR.
3
7
3
0
X 4
0
Y 4
Programmable Controller
45
RUN
Application cassette
Communication cassette
X3
X1
FP-X
60
90
Panasonic
RUN
PROG.
FP-X C14
min.
max.
V0
V1
45
Analog volume
Tool port connector
0V
Y2
Y1
Y0
24V
C0
C1
C2
Y3
C3
Y5
Y4
13.6
3.5
Application cassette
Communication cassette
Battery
Expansion unit connector
79
8.6
79
AFPX-C30 (The same dimensions apply to the expansion I/O unit AFPX-E30)
100
N COM
COM
RUN
X1
X0
X3
X2
X5
X4
X7
X9
X8
X6
XB
XA
XD
XC
XF
XE
2-M
4o
r2
PROG. ERR.
0
8
0
Y
8
7
F
7
ARCT1B273E
DIN hook
90
FP-X C30
RUN
PROG.
min.
82 0.5
Panasonic
max.
V0
Analog volume
V1
0V
USB connector
24V
Y0
C0
Y2
Y1
C1
C2
Y4
Y3
Y7
C3
Y5
Y6
Y9
Y8
YA
C4
YC
YB
YD
FP-X C14
Function cassette
Battery
Expansion unit connector
AFPX-C60
52 0.5
92 0.5
FP-X C30
182 0.5
FP-X C60
190
N COM
COM
RUN
X
Y
X0
PROG.
X3
X2
X5
X4
7 8
17 18
7 8
17 18
XC
XF
COM
NC
XE
COM
COM
COM
X11
X13
X12
X10
X15
X14
X17
X16
X19
X18
X1B
X1A
X1D
X1C
X1F
X1E
F
1F
D
1D
FP-X C60
V1
V2
max.
V3
0V
XA
XD
max.
V0
min.
USB connector
X8
XB
Panasonic
min.
24V
X6
X9
ERR.
0
10
0
10
RUN
PROG.
Analog volume
X7
Y0
C0
Y2
Y1
C1
C2
Y4
Y3
Y7
C3
Y5
Y6
Y9
Y8
YA
C4
YC
YB
Y10
YD
C0
Y11
C1
C2
Y12
Y13
C3
C5
Y14
C4
Y15
Y17
Y16
Y19
Y18
Y1A
C6
Y1C
Y1B
Y1D
( 0.5 )
25
60
POWER
I/F
L
ERROR
45
Status
display LED
(7)
Panasonic
Expansion connector
90
AFPX-EFP0
FP0-A80
45
X1
90
2-Axis Linear
Interpolation
Simultaneously
in 2 Pairs!
DIN hook
Power connector 24 V DC
Expansion hook
Printed in Japan.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
http://www.nais-e.com/plc/
Panasonic... the new name for
New