Вы находитесь на странице: 1из 88

JB-QB-KCRH

JB-QB-KCRH .
JB-QB-KCRH
.

(EMU)

,
,

/
,

V1.0

V1.0
V1.0

JB-QB-KCRH
MKD(EMU).
(SDCU)

DC110V(:

1.5KG

USB

CAN

(, , )25664 LCD

300mm:
:
80dB, :

, "" FIRE1 10V+, 2A/110VDC

, "" FAUL 110V+, 2A/110VDC

RBL 110V+

(SHD)

: <0.8W;
: <1W

24VDC, .

00.8/;
05/()

175

(LHD)

10kV

2- 1
2-M49
4-4.5*8.5

2- 2

2- 3

USB

13

10

2- 4

(SDCU)
(24VDC, RS458)
.
, :
, , (
, ).
(SDCU)CAN, :
, .
TCMSIO, .
(SHD)
, .

(),
,
, RS485,
.

2- 5.
1(),
CAN,
"" , "" .
CAN,
(:
2- 5 JB-QB-KCRH

CAN
A

Mc

01
07
, , , ,
, , .
30NM(3)
JB-QB-KCRH(EMU)4- 1,
, (LCD), , USB.
2LED, "" ""
;
25664LCD, USB,
, .
10, 1:
Test, , , , , 2:
Mute, Reset, Set, Query
Enter.
4- 1 JB-QB-KCRH
JB-QB-KCRH(ETS):
.
.
.
, .
.
.
.
.
JB-QB-KCRH(EMU)LCD
:

, , , , ,
.
SDCU, SDCU().
:
SDCU, MuteEnter, SDCU.

, ,
, LCD4- 2, 1
:
JB-QB-KCRH, 2(), 3, 4
.
, 33(CAN)
, 1, 2, 3SDCU(SDCU,
SDCU);
411,
1#, 2#,
, 9#, , LCD
.
4- 2.
4- 2, 4, V2.1.

:
1), , ;
2), ;
3), 180,
.
4- 2JB-QB-KCRH

JB-QB-KCRH, Test:
LCD, 4- 3,
, LCD, , , .
, LCD
, .
4- 3
4- 3, LCD, ,
LCD;
(), , LCD
4- 4, 4- 54- 6, LCD
;

(), 4- 7
.
, , LCD, .
, 4- 8,
.
4- 4
4- 5
, Reset, , .
"" !
:
.
, "" .
!
4- 6
4- 7
4- 8
:
1)1.Set RTC();
2)2.Set SDCU();
3)3.Set Port(/);
4)4.Del. Record(/);
5)5.Set Sensor Address(
);
6)6.LHD Adjust(LHD);
7)7.Set Sensor Param.();
8)8.Exit().
1)~4);
5), 7)()
.
, Set4- 9
.
, Enter
.
:
1.Set RTC, Enter.
4- 9

JB-QB-KCRH(EMU)1.Set RTC
, , .

, Set4- 9
, 2.Set SDCU, 3.Set Port,
4.Del. Record, 5.Set Sensor Address, 6.LHD Adjust7.Set
Sensor Param., Enter, 4- 10(1
), (((/
, :
((, ).
, Enter.
4- 10
, "" (3),
, ;
.
:
2.
().
().
:
:
0829, :
, 60, .

, Set4- 9
, Enter,
LCD4- 11.
,
, :
1, 2.
4- 12, .
4- 11:
""
""
,
, ((
.
Enter, ,
.
, Reset, ,
, .
1.Set RTC, 60, .

(2.Set SDCU, Enter


(4- 10), Enter2.Set SDCU
, 3-13.

4- 143, .
4- 13
2.Set SDCU2LCD4- 134- 15.
4- 132.Set SDCU, 1Car No.()
:
EMU1#, 2#, 3#(,
);
2Failure Buzzer:
ON/OFF(/), "" ,
:
ON/OFF(/), "" ,
:
, 1, 2, 34- 15
, ((.
4- 14
4- 15
4- 15, 1RS232 Baud:
;
.
1:
, /
, (2
, ).

, /, 2, ,
(/).
RS485,
.
RS232()
.
:
, Enter
;
, .
2.Set SDCU:
Reset, ;
2.Set SDCU, 60,
.

, Set4- 9
.

(3.Set Port, Enter


(4- 16), Enter3.Set Port
, 4- 18, /.
4- 16
4- 17
4- 18(Mc1, Mc2)
3.Set Port6"/" .
2.Set SDCU"Car No." 13(Mc1, Mc2), EMUSDCU
9, 3.Set Port14- 18, 24- 19;
"Car No." 2(Tp), SDCU4, 3.Set Port
, 4- 18;
4- 20.
4- 18, 4- 194- 20, ((
(ON/OFF:
/);
((.
4- 19(Mc1, Mc2)
, Enter
;
:
JB-QB-KCRH, !
.
.
, (),
, .
, , .
(), (SDCU)1(Fail
), .
, (SDCU);
"" .
, 1#SDCU2#, 3#SDCU.

JB-QB-KCRH(EMU), Set
4- 9.
(4.Del. Record, Enter
(4- 21), Enter4.Del.
Record, 4- 23.
4- 23, Enter
/, 4- 24, /
;

Reset, .
4- 21
4- 22
4- 23
4- 24
(1#, 2#, 3#SDCU
, 6), !
!

JB-QB-KCRH(EMU),
, (2- 5)1#, 2#,
, 9#, ;
.
, (
).
"" ,
(2- 5, ).
2- 5, 4274- 30!
(5.Set Sensor Address, Enter
(4- 25).
, Enter5.Set Sensor Address(
4- 274- 28),
.
4- 25
4- 26
4- 27()
4- 27, (2#1#
);
4- 28, 9, 9
(4- 286).
4- 294- 28Enter,
, 4- 29, "" .
, 4- 30,
;
4- 31.
4- 29 ()
4- 30()
4- 31 ()
,
, .
, "" ;

"" .
, , , .
,
;
:
, (,
, 5, 67, 6).
(), ""
.
, 61(
), , 2#,
5#, 6#"" ().
(25.Set Sensor Address, Enter
(4- 25), Enter5.Set
Sensor Address, 4- 27,
.
, "" ,
, "" .
, .
10, .
2, (
).
, , "
" .
(LHD)
(6.LHD Adjust, Enter
(4- 32), Enter6.LHD Adjust
, 4- 34:
(Enter).
, SDCU1(SDCU3)SDCU2;
5.Set Sensor Addr.;
6.LHD Adjust;
7.Set Sensor Param..
4- 32 LHD
4- 33 LHD
4- 34 LHD()
4- 34, Enter4- 35(),
, SDCU4- 36;
, 4- 37, 604- 38
LHD.
4- 35 LHD()
:

1)(LHD)(), LHD
(LHD).
2)LHD, (SDCU).
LHD, SDCU90,
.
4- 36 LHD()
4- 37 LHD()
4- 38 LHD()

(/
), ((, 2, 3, 4
();

((, 4- 42.
"7.Set Sensor Param." ,
(2- 5, );
"" 4.Bus State,
.
4- 39
4- 40
4- 41 ()
4- 42 (1#)
, 2:
(S), (TH), (LHD);
3:
, , ;
, , .
:
1)(S), :
80~120%, ;
=100%.
2)(TH):
(), :
3)(LHD):
, :
(:
, )
4)"" ,
, :
;
=5;
:

,
.
().
, , Enter
"" , ;
, 4- 43().
4- 43 ()
LCD(02#),
Enter, (01#03#)
, (02#).
, 0.
Enter, SDCU,
Enter!
.
, LCD.
4- 43, , (, (, (
(, .
, "" ,
, "" .
, 1, , "
" ;
.
EMU, JB-QB-KCRH(
EMU), ,
.
(LHD).
4- 1 Mc(Mc1Mc2)

/
/
4- 2 Mc(Mc1Mc2)LHD

//
4- 3 Tp

"" "" ,
, EMU, "+241" .
FIRE();

2)2.Inquire FAIL();
3)3.Sensor State();
4)4.Bus State();
5)5.Sensor Param.();
, Query4- 44
.
, Enter
.
1.Inquire FIRE, Enter
.
4- 44

JB-QB-KCRH(EMU)
, 200.
(), ,
.

, Query4- 44
, Enter4- 45(),
, .

4- 45, Enter4- 46(


3, 4"FIRE" );
,
4- 47, ,
.
4- 45
4- 46
:
(SMK), (TEM), (LHD)(ST),
(TL)(SL, STL).
4- 46, ,
.
, (3);
, .
, Enter, ,
.
4- 47
()

JB-QB-KCRH(EMU)
, 200.
(), ,
.
, ,
(CAN), .
, Query4- 44
, 2.Inquire FAIL, Enter
4- 48(),
, .
4- 48
4- 48, Enter4- 49(
3, 4"FAIL" );
, 4- 50
, , .
4- 49
4- 50
JB-QB-KCRH(EMU)3:
, , .
4- 493201441012:
34Mc104#.
, :
(COM), (SMK), (TEM), (LHD),
(ST, SL, STL, TL).
:
(BELL1)(RBL)(BELL2), (RESET1)
(RST)(RESET2).
4- 49, ,
.
, (3);

, Query4- 44
, 3.Sensor State, Enter
, LCD4- 51, 1#2#
:
, , (//), , ,
.
, 0.
4- 51
, 2- 5,
.

Mc1Mc23.Sensor State4, Tp3.Sensor


State2, ((
.
3.Sensor State, ,
, (/).
4- 514- 52, Enter.
4- 52

JB-QB-KCRH(EMU),
Query4- 44,
4.Bus State, Enter
, 4- 53, 4- 54, 4- 55, 4- 56
;
, .
4- 53 (Mc1:
)
)
, (/)
, , .
4- 55 ()
4- 56 ()

JB-QB-KCRH(EMU),
Query4- 44,
5.Sensor Param., Enter
, 4- 57:

LCD1,
, 4- 582#.
1(4- 57):
:
(SMK), (TEM), (LHD)(ST, SL, STL, TL)
(:
.
(S=50/100).
(G=50).
4- 57 (01#)
2, 3, 4, "
" ;
3(457A01:

01#A, =1);
4(4- 57V2.1).
, 0.
4- 57, 4- 58, ResetEnter
, .
, (SDCU),
;
, , .
,
, .
, ().
, , 4- 59
, (
), , "" (), ,
(, FIRE1110V+);
, .
4- 59

4- 59, 1, 1
, , "" ;
24:
1, 2:
SMK, TEM, LHD,
:
ST, SL, TL, STL), 3().
Mc1, Mc2, 4#, 5#6#
, "" (, FIRE2
110V+).
"" .
, 4- 4.
4- 4, ,
4- 4.
4- 4

FAUL110V+

FIRE2110V+

,
.
!
, ;
.
:
1,
, (SMK);
, , 1
, .
1, 1,
(ST, SMK+TEM);
, LCD, ST.
, , LCD
.
.
, 3, 2
.
(, (.
Mute, 4- 60(LCD1,
).
, , "" ,
(BELL1).
4- 60 ()

200, 200,
.
3, 600.
, , ,
(), , .
Mute, .

, ,
, (), ,
"" , LCD().
, 4- 61
, (

), , , (
, FAUL110V+);
, .
4- 61, 1, 1
, , "" ;
24:
1, 2:
SMK, TEM, COM, 3
().
, 4- 5.
4- 5, ,
4- 5.

4- 61
4- 5
JB-QB-KCRH(EMU), ,
, ,
.
, (3), 2
.
Mute, 4- 62(LCD1"" ).
, , .
(, , )200
, 200, .
3, 600.
, ,
, .
4- 62
, , ""
, , , .
2- 5, ()(
2), ;
(),
;
(10), "
" , , "" (0.3, 0.3
).
"" ,
(),
, ;

"" .
"" , 4.Bus State
.
4- 5601#02#, 4- 63
01#02#.
, (COM),
, LCD4- 64, ,
(
), .
4- 64
EMU3JB-QB-KCRHCAN
, (Tp), (Mc1, Mc2)
.
"" , "" ""
.
, "" "" .

, 1~2,
, CAN.
, 465, "" ,
;
, , .
, .
,
, , .
, .
, ;
!
, ,
, .
4- 65
4- 66 ()
,
, .
, .
.
.


, CAN
, , 4- 67
, , , ""
;
4- 67, 1, 1,
"" ;
24:
1, 2, 3, 4
(), 5.
:
(COM), (SMK), (TEM), (LHD)
(ST, SL, STL, TL), OTH().
4- 67

, , 2
(, (.
Mute, 4- 68, ,
, .
, MuteReset,
, CAN.
4- 68
JB-QB-KCRH,
, .
.
.
.
.
JB-QB-KCRH(EMU)
, Reset, (4- 69).
4- 69, Enter, , 4- 70
2.
60, , ,
.
4- 69
4- 70
, ,
, CAN, 1
, .

JB-QB-KCRH, Reset
, , ,
CAN, .
4- 71
, , Reset
(2),
.
, .
JB-QB-KCRH(EMU),
RST, 110V+1(),
.
RST, 110V+Reset,
"" .
, LCD4- 2,
, ;
, ;
, Reset.
Reset
.
JB-QB-KCRH(EMU)(),
.
, Mute, , CAN
, 1.
Mute, LCD(4- 60, 4- 62LCD
"" ), , ,
, .
JB-QB-KCRH(EMU),
RBL, 110V+1(),
.
RBL, 110V+Mute,
"" .

1)
2)

X1, X2,

, .
"Y1" , "Y2"

, :
' JB-QB-KCRH '

, :
1) , , .
2) 2 ().
3) ,
"110V+" , "110V-" , .
(
).

, :
1);
2);
4);
5).
(),
.
:
Set>>2.Set SDCU.
:
Set>>5.Set Sensor Address.

, .
, ,
.
30 ,
.
, (/)
.
:
1#, 2#, 3#, 4#, 5#, 6#, 7#, 8#, 9#;
4 , 1#, 2#, 3#, 4#;
5#(6#).
,
;
.

1.

1).
2)(1#), 2 Y1\Y2,
.
3)1#:
1 (), (
), "" (), TCMS
.
4),
, .
,
.
2.
2):
"" (2 )
.
:
"" ().
3).
4):
(),
(
), "" (), TCMS
.
5), ,

.
, ,
.
,
.
5- 1.JB-QB-KCRH

:
:

("" , "" )

\
\

:
()

(
, 3, 3
, 3), 7- 1
.
, TCMS
, TCMS.
7- 1JB-QB-KCRH

,
, ?
,

7- 2.
7- 2 JB-QB-KCRH

?
?

X1, X2,

"Y1" , "Y2"
, .

;
.
X1, X2, ;

, .
"Y1" , "Y2"
, .

YHCS
8- 1
8- 2 YHCS

, "M"

(5m,2)

(7)
(7)
(10)
(13)

, , ;
;
.
.
,
.
JB-QB-KCRH:
, , , ;
, , .
JB-QB-KCRH,
, , .
.
JB-QB-KCRH:
:
:

, , ,
, .
, .


JB-QB-KCRH Fire alarm system Service manual V1.0
Guangzhou Control Electronic Science and Technology Co., Ltd.
Page I
Huilezhou Control Fire Figurehting Equipment Co.,Ltd.
JB-QB-KCRH Fire alarm system Service manual V1.0
JB-QB-KCRH Fire alarm system
Use and service mannual V1.0
Fire alarm system
Use and service mannual
Macedonia(EMU)Project
Guangdong Guangzhou Control Electronic Science and Technology Co., Ltd.
Guangdong Huilezhou Control Fire Figurehting Equipment Co.,Ltd
10-May-15
Content
Function and approach
Instruction
Technical parameters
Structure declaration
Working principle
Safety instruction
Operating instruction
Language switch
Boot display
Self-inspection
Parameter setting
Location name of the detector
Information inquiry
Fire alarm
Failure warning
Failure warning for the loop disconnect of serial communications bus
Car alarm
Alarm reset
Alarm silence
Installation and commissioning
Installation
Commissioning
Service
Maintenance level content and plan
Fault handling, replacement principle and maintainence
Breakdown alarm by detector
Misinformation of fire alarm by detector
Disassembly
Replacement principle
Reinstallation
Come into use/functional test
Special tools and equipments, quick-wear part and list of spare parts
Special tools and testing equipment

Quick-wear part and list of spare parts


Waste disposal program
Instruction of transport and storage
Basic requirements for transport and storage
Transport instruction
Storage instruction
Abbreviation and index
Unpack and inspection
This outline is applied to the JB-QB-KCRH of Guangzhou Control Electronic Science and
Technology Co., Ltd.
Fire alarm system and maintanence for MKD(EMU) project
Fire alarm control unitSDCU
Input power voltage
Floating ground system DC110V( allowable fluctuation range:
Power dissipation
Environment temperature
Relative humidity
Controlled points
7 pcs
Boundary dimension
Cabinet size:
Net weight
About 1.5kg
Position of mounting hole
Panel mount
Tapping of cabinet door
Tapping of cabinet door
USB Virtual serial communication port
With the communication way of the detector
Dual serial communication port
Communication between control units
CAN Communication
Display format Of display screen
Characternumber, letter, sign) uses 25664 lattice LCD screen
Alarm volume
300mm from the sound source
Fire alarm
80dB,breakdown
Linkage output of fire alarm
When the relay contacts,"fire alarm", FIRE1 connects with 10V+, 2A/110VDC
Fire alarm output of driver's cab
Linkage output of breakdown
When the relay contact is breakdown, FAUL disconnects with 110V+, 2A/110VDC
Long-distance noise reduction input
RBL electric point on 110 v + is effective
Long-distance reset imput
DetectorSHD

Monitored state: <0.8W;


Alarm condition : <1W
Rated operational voltage
24VDC, it will be provided by fire alarm control unit
Applicable enviromental temperature
Applicable wind speed
00.8 meter/second
05 meter/second(testing)
Mounting dimension
Weight
About 175 grams
Communicating function
Ordinary temperature sensing cable
Model
Alarm temperature
Applicable environment temperature
External diameter
Diameter of wire
Material of wire
Zinc-coated wire
High pressure resistant
10kv pressure resistant between over sheath and wire
Bend Radius
Affordable tensile force
Over sheath
Outline dimensional drawing
Figure2-1 is the outside view of fire alarm control unit
2-M49 earthing screw
4-4.5*8.5 countersink
Minimum reserved outlet diemension
Figure 2-2 Outside view of fire alarm detector
Explosive view
Figure2-3 Explosive view of fire alarm control unit
Steel space support
Case
USB board
Slotted Drives bi-pass double-screw bolt
Lamp panel
Display screen
Main board
Screw
Power strip
Socket
Nut
Horn
Baseboard
Sunk screw
13 bit needle-shape

10 bit hole-pattern
Serial no.
Name
Specification
Number
Inclduing spacer, shrapnel
Remark
Figure2-4 explosive view of fire detector
Connector assembly
Front cover
Base 2
lower cover
Circuit board
Aluminium cap
Roof cover
Working principle of fire alarm control unit (SDCU)
Through the probe bus,the fire alarm controller and the detector (24 VDC power supply, RS458
port) constitute a closed communication loop.
Fire alarm controller can also manage and conFigureurate the local detectors , include:
Check the operational parameters of a detector, block or open a detector, conFigureurate the
parameters of a detector (such as temperature alarm threshold, the smoke alarm sensitivity,
etc.).
The hosts (SDCU) of the fire alarm controllers exchange information through the CAN bus , th
exchanged information including:
The monitoring result of the fire alarm and fault from the detector.
Fire alarm controller and TCMS upload the status information of the fire alarm and fault to the
fire alarm system by the IO interface.
The working principle of the detector (SHD)
The detector detected by infrared scattering of smoke particles, and attached the temperature
detection function.
It can monitor the environmental the density of smoke particles (concentration) and the change
of environmental temperature, at the same time, the embedded oprate the computation and
caomparition based on the sampling data of smoke and temperature ,and the alarm information
will be output through the probe light after reaching the alarm threshold condition.And at the
same time transmit the smoke sense, temperature sense and other status information to the fire
alarm controller through the RS485 communication port.
The system structure
The framework of fire alarm system structure as shown in attached Figure 2-5.
The fire larm system conFigureurate fire alarm controller to each carriage(also called as fire
alarm controller host),the faire alarm controller of each carriage of the train communicate
through CAN bus,in order to share the information dada of the "fire alarm " and "fault"between
each fire alarm controller.
The fire alarm controllers of the fire alarm system exchange data through the CAN
bus,therefore must number each fire alarm controller independently( Address:
Figure 2-5 JB-QB-KCRH connected relation between the structure of fire alarm control unit
and detector
The driver room fire alarm linkage output
Long distance reset signal
Long-distance noise noise reduction signal
Twisted shielded pair

CAN bus
Port A
Arrangement
Port I
Fire alarm host
Smoke heat compound detector
Wiring diagram
Mark
Number of point
Subarea
Change the order number
Sign
Year, Month, Day
Design
Main design
Approved by
Ma Liying
Chen Xihong
CSR.Zhuzhou Electric Locomotive Corporation Limited (ZELC)
Fire alarm
Fire alarm system of Mc car
Electrical schematic diagram
Page 01
7 pages in total
Disconnect power before detachment or installation; and then pay attention to the protection
over fire alarm controller panel and chassis, while detaching or installing the sensor, pay
attention to the cleanliness of the smoke chamber to avoid the dust getting into the chamber.
The torque that fire alarm controller earth stud can stand is 30N M (3KG)
The appearance of JB-QB-KCRH(Macedonia EMU project) fire alarm controller pannel is as
shown by Figure4-1; the pannel is mainly
Above the center of the panel are 2 LED lamps, respectively red "fire alwarm"
In the center of the panel is the LCD screen with
Keypad has ten keys, from left to right in the the first row
Test, , , , ,from left to right in the second row:
Mute, Reset, Set, Query andEnter
keys.
Figure4-1 JB-QB-KCRH fire alarm controller panel illustration
The function of JB-QB-KCRH(Malaysia ETS project) fire alarm controller key are basically
as below:
System self-checking function key
Bummingremoval key
Get back to monitoring interface at the time of system reset or operating setting and inquiry
revise the current parameters, manu move or record the shift key
Cursor moving key
Function setting key
Inmquiry key
Enter key
JB-QB-KCRH(Macedonia EMU project) fire alarm controller LCD has the

The normal monitoring status display, self-checking function display, default display,fire alarm
display, system setting display and inquiry function display.
After turning on SDCU power, SDCU auomatically turns to user interface in local language
(Macedonian language)
shift to user interface in English language
Turn off SDCU power, press the keys of MuteandEnter at the same time, and turn on
SDCU power
starting interface instruction
After making sure correct installation and wiring, turn on the power switch on the controller
panel, after the power-on self-test of the fire alarm controller, LCD screen dislay will be shown
as Figure4-2, and the first row on the LCD displays the model of the fire alarm controller
JB-QB-KCRH, in the second row displays the serial No. of the vehicle (the serial No. of the
controller) and the corresponding compartment type, and on the third and fourth row display
the current calendar clock.
In addition, the right side of the third row display the controller node connecting to the
controller (CAN bus) with three black blocks that are respectively labelled 1, 2 and 3 SDCU
(when the controller never communcates with any other SDCU, only SDCU is displayed)
On the right side of the fourth row, 11 black blocks are used to display the online detector
under the control of the controller, from left to right they are respectively 1#,2#
9# detector, when the detector in connection with the controller is not online, the black block at
the corresponding place of the LCD screen will disappear
Figure4-2 interface is the display interface of fire alarm controller under normal monitoring
status
In the interface as shown in Figure4-2, the central part on the fourth row is version number of
the embedded software of the control which is displayed as V2.1 in the Figure
Backlight function of LCD
Instrcution on Ccontroller LCD backlight function
1) when the alarm arises, the backlight automatically turns on and keeps lighting up
2) when the backlight is at off state, press any key to turn on the backlight
3) When backlight is on status and free alarm, in case of no key operation within 180s , the
system will automatically turn off backlight.
Figure 4-2 JB-QB-KCRH normal monitoring display interface of fire alarm controller
Interconnection controller node identification
Online detector node identification
Under the normal minitoring condition of JB-QB-KCRH fire alarm controller, presss Test
to get into self-checking function
Turn on LCD backlight, and display the prompt interface as shown in Figure4-3, and then the
system automaticaly test the related interfaces of the controller, LCD screen, signal indicating
lamp, hummer and the communication function
Therefore, The operators and maintenance personnel can check or measure the consistency
between the corresponding ports and the prompt message on the LCD screen based on the
prompt on the screen, and thus judge if the controller operates as normal.
Figure4-3 fire alarm controller system self-checking prompt interface
After displaying self-checking prompt as shown in Figure4-3, get into the display dection on
LCD screen, furthermore, the operators can observe if the point matrix on each row and each
list of the LCD screen are normal
Then, the system gets into hummer (horn) sound, indicating lamp test and the related port test;
LCD screen respectively display the Figure4-4, 4-5 and 4-6; at that time, the operators will
notice the hummer and the indicating lamp above the LCD screen

In the end, the system enters the inspction stage of other componets (such as the storage), if
everything is normal, the interface as shown in Figure4-7 will be displayed
In this way, the system can finish a complete self-checking process, turn off the backlight of the
LCD screen and go back to normal monitoring status
If the storage fails to pass the test, the interface as shown in Figure4-8 will be displayed, in
that case, immediatelt contact the maintenance or repair personnel
Figure4-4 fire alarm controller ports self-checking prompt interface related to fire alarm
Figure4-4 fire alarm controller ports self-checking prompt interface related to fire default
Press Reset in the process of system self-chcking, the controller will immediately stop
self-checking and go back to monitoring status
Please maintain or repair in time the fire alarm controller failing in "self-checjing" fucntion
note:
Daily self-checking test shall be done for fire alarm controller
The power switch of the controller failing in self-checking fucntion cannot be turned on while
the train is in operation
be sure to remember!
Figure 4-6 fire alarm controller hummer turn-off prompt interface
Figure 4-7 Normal prompt interface of system self-checking storage
Figure 4-8 system self-checking storage failure prompt interface
The parameters of the fire alarm controller contains the following:
1)1.Set RTC(controller calendar clock)
2)2.Set SDCU(controller operation parameter configuration)
3)3.Set Port(open/close the alarm function of certain detector under the control of fire
alarm controller
4)4.Del. Record(remove the historical records fire alarm/failure)
5)5.Set Sensor Address(start the detector under the control of fire alarm controller and
automatically generate the number based on the route)
6)6.LHD Adjust(detector LHD self-adjusting)
7)7.Set Sensor Param.(revise the working parameters of the detector)
8)8.Exit(exit).
The setting function from item 1~4 of the fire alarm controller is used to revise the working
and operating parameters of the controller itself
While the function from item 5~7 is used to allocate the communication address of the
detector (the serial No.) and some working parameters within the detector)
Under the normal monitoring status of the controller, pressSet to enter the menu option
interface as shown in Figure4-9
Press andorandto move the cursor, press Enter to enter the
corresponding functions.
For example,
When the cursor is located at 1.Set RTC,press Enter to enter calendar clock setting
function of the controller
Figure4-9 setting function menu option interface
Type in system password
The setting functions of JB-QB-KCRH(Macedonia EMU project) fire alarm controller, besides
1.Set RTCmust be entered by typing in passwords to avoid any possible changes of the
system configuration by the personnel unrelated

Under the normal monitoring status of the controller, press Set to enter function setting
menu option interface, pressand to move the cursor to 2.Set SDCU, 3.Set
Port, 4.Del. Record, 5.Set Sensor Address, 6.LHD Adjustor7.Set Sensor
Param.; press Enterfirst enter password input interface, as shown in Figure4-10 (in the
first row displays the prompt information for operation); after typing in correct passwords,
increase or decrease the Figure of the password by pressing (and(, note:
Press (or(for long, the Figure will roll more quickly
After reaching the password Figure, pressEnter to enter the corresponding function
setting interface
Figure4-10 Fire alarm control configuration password input interface
In case of typing in wrong password, the system will display corresponding prompt for
"wrong password" (for 3s), and then automatically get out of setting operation and back to
normal monitoring status
Continue related operation in case of the need for function setting
Password rule
The password is composed of a double digit Figure
The first digit from the left is the total sum of the months (using the single digit) in control
system calendar--- the ten-digit of the password.
The second digit from the left is the total sum of the dates (using the single digit) in control
system calendar--- the single-digit of the password.
For example,
The current date is;
Aug.29, the password is:
In the display interface of password input, in case no key operation within 60s, the system
automaticallly gets back to the main monitoring interface
Calendar clock setting of the controller
Under the normal monitoring status of the controller, press Setto enter the function
setting menu option interface as shown in Figure4-9, press Enter to get into calendar
clock setting function of the controller, and the LCD screen will have the display as shown in
Figure4-11
In the controller's calendar clock setting interface, press and to respectively move
the cursor to the last and next item, and the items of the calendar clock from the left to right
include:
In the first row is month--date--year, and hour--minute--second in the second row
As shown in Figure,4-12, the cursor is at the position of "year"
Figure4-11 Date and time setting function interface
Change "month"
Change "year"
In the controller's calendar hour setting interface, by pressing andto move the
cursor to the calent clock option to be changed; and then press (and(to increase or
decrease the Figure
After changing the calendar clock, press Enterto save the current Figure, and at the same
time, the system gets back to monitoring interface.
To give up changing calendar clock, pressResetto exit out of the setting interface without
saving the Figure and gets back to the monitoring interface.
In 1.Set RTCsetting interface, in case of no key operation within 60s, the system will
automatically get back to the main monitoring interface
Fire alarm controller configuration
Press (to move the current cursor to 2.Set SDCU; press Enter to enter password
input interface (such as Figure4-10); press Enterto get into the function setting interface
of2.Set SDCU, after typing in correct password, as shown in Figure3-13

The interface as shown in Figure4-14 will appear for 3s in case of wrong input of the
password, and then the system automatically get back the main monitoring interface.
Figure4-13 One of the fire alarm controller configuration setting interface
2.Set SDCUhas two LCD interfaces, as shown in Figure4-13 and 4-15
As shown in Figure4-13, in the first row of2.Set SDCUsetting interface is is Car No.
setting zone
The EMU project in Macedonia, the valid mumber of the parameter of the fire alarm controller
is1#, 2#, 3#(the carrage tp will be shown in the counterplace)
The second line is Failure Buzzer:
ON/OFF,using for if the the "fault" hum will sound out when the controller find the detector's
alarm,default:
ON/OFF,using for if the the "fire" hum will sound out when the controller find the detector's
alarm,default:
Among,the cursor will move by press andkey in the parameter value in line
1,2and 3 and the interface which is shown as Figure 4-15,by pressing key(and(to
modify the value of the patameter which the cursor placed,
Figure 4-14, the fire alarm controller coFigureurate password error message interface
Firgure 4-15, the secont of the fire alarm controller configuration settiing interface
As shown in Figure 4-15, the first line isRS232 Baud:
Use to set the serial communication baud rate which communicate with management computer
Use to setting the serial bus communication rate which communicate with the probe.
Note 1:
When the fire alarm or the fault alarm is ongoing,modify the "alarm buzzer"/parameter of
the"alarm buzzer" deliberatly,the state with difined by the parameter can not take effect
immediately may be occoured(mean that if modify these 2 parameters under in alarm, the sound
of buzzer my not be able to follow the chage of the parameters directly).
But, in the no fire alarm/ on fault state, after modify this 2 parameters and save it,the the fire
alarm or the fault appear,the buzzer will work according to the state which difined by the
parameter value(On/Off).
The patameter of the RS485 communication rate must be consistent with detector's
communication rate,and is do not will to be modified by the user at will.
The patameter of the RS232 communication rate must be consistent with the communication
rate(baud rate) of the management computer's port.
Saving the modified parameter
After make sure with the modified value of the patameters,press Enter key to finish saving
the oprating parameter value and back to the moitoring interface.
Otherwise, the system will abandon the currunt modified peremeter value.
Excit the 2.Set SDCU to the monitoring main interface.
PressResetkey, the currunt modification will not be saved and will exit to oprate the
parameter setting funtion.
In the 2.Set SDCUdesplay interface ,if there is no opration with 60 seconds, the system
will return to the monitoring main interface.
Port configuration
The controller is under the normal monitoring state, pressSet key to enter the option
interface of the function setiing menu, as shown in Figure 4-9.

Press (key twice to move the cursor to 3.Set Port,press the "Enter "key to enter the
password input interpace(as shown in Figure 4-16),after input the password correctly, press the
"enter"key to enter the 3.Set Port's setting function, as shown in Figure 4-18,to finsh the
Open /Close of the detectors which is under the jurisdiction of the fire alarm controller.
Figure 4-16, the password input interface of the pot configuration
Figure 4-17, configuration error message interface of the port configuration
Figure 4-18, the first of Port configuration interface (Carriage Mc1, Mc2)
Every screen of the 3.Set Portis permitted to be conFigured with 6 detectors' "Open/ Close
State"
when the "car no." in 2.Set Portis 1 and 3(Mc2,Mc2 Tp),SDCU of the EMU program is
permitted to be connected with 9 detectors,the first screen of the 3.Set Portis as showm in
Figure 4-18, and the second screen is as shown in Figure4-19.
When the "car no."is 2 (Tp),SDCU is permitted to be connected with 2 detectors,3.Set
Portin interface only one screen at a time, as showm inFigure 4-18.
As showm in Figure 4-20
As shown in Figure 4-18, Figure 4-19 and Figure 4-20, Press (and (key to modify the
parameter's value in the interface,where the curse appears cuttuntly .
(ON/OFF);
Press (and (key to move the cursor
Figure 4-19, the second of Port configuration interface (Carriage Mc1, Mc2)
After make sure with the modified value of the patameters, press"Enter"buttrn to save the
currunt patameter values and return to the interface of monitoring.
Suggestion:
If there is an error appears in the correct configuration,please do not shut down the detector of
the JB-QB-KCRH fire controller randomly.
Undefined bookmark
As shown in
During the train operation, when a detector always at fault(and could not immediately find out
fault source), the probe with this number inside the controller could be shut down temporaryly,
and the state should be reported to the superviser and be recorded in detail.
But, in case the detector must be re-open for the parking overhaul,to avoid fire hazard cannot
be found in a time.
To shut down a detector(shielding),there will be a record generated in the system(SDCU)
(seved in the FAIL area),where corresponding time and shielding detector number will be
saved in the local memory .
But,other online computers(SDCU) will not save this shielding oprating;
This is different from the state of the "fault record".
Means,the record of the shielding oprating of 1#SDCU will not be saved in 2#,3#SDCU.
Record management
When the JB_QB_KCRH(Macedonia EMU Project)controller is under the normal monitoring
state, press "set" putton to enter the optional interface of the fanctional setting menu, as shown
in Figure4-9
Press (key three times to move the cursor to the position of 4.Del.
Record,pressEnterkey to let the system into the passwod input interface(as shown in
Figure4-21),after the password is corrrect ,pressEnterkey to enter the setting funtion of the
4.Del. Record,as shown in Figure4-23.
As shown in Figure4-23, pressEnterkey to let the controller permmanently record all of
the fault in the memory/ delete the fire alarm record, as shown in Figure4-24,it will retourn to
the monitoring interface automatically after the controller finish deleting all the historical
record of falt and fire alarm

PressResetkey,the system will return to the monitoring state without deleting he record.
Figure 4-21 record management password input interface
Figure 4-22 record management error message interface
Figure 4-23 record management interface
Figure 4-24 deleting record waiting interface
The deleting record funtion can delete all the history records from the permenent memory of
the controller(include the fire alarm and affire record generated from 1#,2#,3#SDCU),and
unable to be restored.
Please be careful!
Detector automatic numbering
In the JB-QB-KCRH(Macedonia EMU Project)fir alarm system,the serial communication loop
between the fire alarm controller and the detector connect the detector 1#,2#...9# in turn to the
port of the controller serial commucation I,
Finally return to the port of the controller serial commucation II
It is the suggected method from the system
The detector will number the detector automatically according to the distence between the
location where itself located in the serial loop communication and the port of the controller
I(The closer distance to port I, the smaller the node number will be )
Before the "detctor automatic numbering"start,must make sure the loop of the detector serial
communication chain of the monitored deteor are closed(means,from port I and retun to port II
after passing each detetor, as shown in Figure2-5)
When the fire alarm system can not ensure the structural integrity as shown in Figure2-5, the
result may not be clearly shown as shown in Figure4-27 to Figure4-30
Press(key 4 times to move the cursor to the positon of 5.Set Sensor Address,press
Enter key to the password input interface(as shown in Figure4-25)
Afer the password input is correct,pressEnterkey to enter the setting function of the
5.Set Sensor Address(as shown in Figure4-27),to complete the assignment of the
automatica numbering of the monitored deter node from the controller.
Figure 4-25 detector automatic numbering password input interface
Figure 4-26 detector automatic numbering password input error message interface
Figure 4-27 detector automatic numbering configuration interface(waiting)
As shown in Figure4-27,it show that the node number is not unified with the actual path(2#
and 1# are out of order)
As shown in Figure4-28,if it is sure that 9 dector are connected,means that the the number of
the 9 dectors connected to the controller may be repeated(as show in Figure4-28,it only show 6
numbers)
As the interface shown in Figure4-28,pressEnterkey,the controller will output the order of
"dector automatic numbering",as shown in Figure4-29,the controller truly output "dector
automatic numbering"command at this moment.
Waiting for the dector automatic numbering is finished,if it is succesful,it will shown as
Figure4-30,the node number in line 2 will be order from left to right in line with the growing
up on the interface.
Otherwise,it will shown as Figure4-31.
Figure4-29 dector automatic numbering configuration interface(output)
Figure4-30 dector automatic numbering configuration interface(Succeed)
Figure4-31 dector automatic numbering configuration interface(failure)
When a detector in the carriage break down,and cannot work normally, just need to remove the
detctor from the communication loop, and keep the communication loop between the controller
and the other detector is closed.
At the moment, the "dector automatic numbering"is not recommanded.

Only need to change the port number configuration of the breaking out dector into"close"
For the first time when the installation of the fire alarm system is complete,to adjust and test
after all the equipment is connected correctly and normal,
Firstly,operate the dector automatic numbering,the field staff must notice clearly regarding the
corresponding number of each detector in each carriage in advance;
And comlpete the operation as follow:
Before electricity,make sure the configuration of the fire alarm controller is correct or
not(include the numbers,numbers of the controlled detector is siut for the carriage type,for
example,5pcs,6pcs or 7pcs,the following example is 6pcs).
If the number of the controller is inconformity from the carriage type(name)where located,then
follow the operation instruction of the "fire alarm controller configuration"to modified.
Power on, because the fire alarm controller communication bus is connected with 6 pcs
detectors with 1 addresssing(Assume that all the detectors are numbered in the factory default
state ),so the controller will send out fault alarm for detector number 2#,5#,6#
Fault alarm from 5#.6# detector(the correspoding failiure indicater)
Press (key to move the cursor to the position of 5.Set Sensor Address,
pressEnterto enter the password input interface(as shown in Figure4-25),after the
password input is correct,pressEnterkey to enter the setting function of the 5.Set Sensor
Address,as the interface shown in Figure4-27, For automatic configuration of fire alarm
detector addresses.
Given the prioity alarm funtion,when When the fire alarm controller detects fire danger into the
"fire alarm state" ,pleaseso not operate the"dector automatic numbering "before the fire alarm
state is uncleared.
When the current "dector automatic numbering "is succesful,Close the fire alarm controller
power supply .
Wait for at least 10 seconds,re-open the controller power supply.
Wait for 2 minutes,make sure the dector of the fire alarm controlleris at normal(means there is
no detecor fault alarm of the controller)
In addition,after the configuration is completed,you can check the stateuof the numbered dector
by using the inquiry function,for eg.description of "the bus status query"
Tempreture sensing cable(LHD)automatic stteting
Press(key 5 times to move the cursor to the positon of 6.LHD Adjust,press Enter
key to the password input interface(as shown in Figure4-32),after the password is corrrect
,pressEnterkey to enter the setting funtion of the 6.LHD Adjustinterface,as shown in
Figure4-34.
Wait for the operator to confirm(,pressEnterkey)
After the fire alrm syetem installation is complete,confirm the SDCU1(SDCU3)and SDCU2
firstly;
Then, doing the operation of 5.Set Sensor Addr.
Continue, doing the operation of 6.LHD Adjust
Finally,doing the operation of 7.Set Sensor Param.
Figure4-32 LHD self setting password input interface
Figure4-33 LHD self setting password input error message interface
Figure 4-34 LHD self setting interface(need to be confirmed)
PressEnterkey in the interface shown as Figure4-37,to show the (command
output)interface shown as Figure4-35,if there is hte echo response reply appears after the
detector operate the temprature sensing cable automatic setting succesfully,the SDCU will
show as Figure4-38
Otherwise, the interface will be shown as eht Figure4-37,if there is no successful reply from
the detector within 60 seconds,the LHD self setting failiure interface will be shown as Figure438.
Figure4-35 LHD self setting interface(command output)
Requirements:

1)As long as the installation of temprature sensing cable (LHD) changes (such as the
replacement of cables),the LHD self setting must be done(means the inner LHD parameter of
the dector self-calibration)
2)colse the controller power supply is (SDCU)is not suitable both when the LHD self setting in
process and completed.
Even if the LHD self setting is succesful,the SDCU should keep operating at least 90
seconds,to let the detector have enough time to save and adapt to the new parameter value.
Figure4-36 LHD self setting interface(wait for reply)
Figure4-37 LHD self setting interface(successed)
Figure4-38 LHD self setting interface(failiure)
Detector parameter setting
The cursor stay the position of the choose of the detector number(the amount of the
administrated detetor of the controller is diffrient bucause of the carriage type/name
isdifferent),press(and(keys can select the detector number which need to
conFigureurate the parameter,meanwhile the parameter value in line 2,3,4will be changed as
the detector number changing(when the parameter value of detector is different)
Press(and(keys can move the cursor to the parameter which will be modified,as
shown in Figure4-42.
Before doing the operation of "7.Set Sensor Param." ,must confirm that the administrated
dector serial communication chain loop is closed(means,from the port I showm as Figure25,return to the portII passing each detector);
Follow the content regarding 4.Bus State inquiry operation of the "bus status inquiry",to
ensure the fire alarm system loop and node number are normal.
Figure4-39 detector parameter setting password input interface
Figure4-40 detector parameter setting password input error information interface
Figure4-41 detector parameter setting interface(detectore number selection)
Figure4-43 detector parameter setting interface(1#Smoke sensitivity parameters of the detector)
Main parameters setting of detector ordered from left to right, line 2:
Smoke sensitivity (S), the temperature alarm value (TH), heat cable alarm sampling threshold
(LHD);
Line 3:
Smoke fire duration, duration of temperature alarms, heat cable fire alarm duration;
Smoke fault duration, temperature fault duration, linear heat cable fault duration.
The meaning of the parameters is as follows:
1) smoke sensitivity (S) parameters expressed as a percentage , the range of allowable values:
80 ~120%, the sensitivity of the parameter value is bigger, the greater the detector sensitivity of
smoke;
The default value = 100%.
2) units of temperature alarm value (TH) parameters:
Degrees Celsius (), the range of allowable values:
3) heat cable alarm threshold (LHD) :
Set the alarm threshold value of heat sensitive cable, parameters units:
(note:
Not allowed to change, by the detector self-tuning automatically set)
4) "duration" refers to when the alarm conditions persist time reach this value, the probe will
emit the alarm, unit of time:
Scond;
The default value = 5 seconds;
Permitted range:

The above allowed range is the adjustment scope which the controller interface allows and do
not represent these values can be accepted by the detector.
Detector will ignore the thoughtable illegal parameter values settings (that is, ignore the
change of the parameters).
For a detector parameter setting, after all the parameter values amended as target value, press
"Enter" key, the controller output "detector parameter setting commands", the parameter sent to
the target detector;
At the same time, the interface display as shown in Figure 4-43 (cursor disappears).
Figure 4-43 detector parameter setting interface (the command output)
When change parameter of a detector (e.g., 02 #)at the LCD interface , if did not press "Enter"
key to confirmin the probe display interface, and exit or directly into the next detector (such as
01 # or # 3) parameter Settings interface, then the detector (02 #) parameter modification is
invalid.
For closed detector, in the parameters set interface display value is usually displayed as 0.
When set in its setting interface, press "Enter" key, SDCU will no longer send modify
command to the detector, it means press [Enter] cannot Enter error!
As shown in the command output interface.
That is to say, at the the closed detector parameter operation interface , the cursor is always
display on the LCD screen.
As shown in Figure 4-43, if still need to conFigure the other parameters of detector, then press
(, (, (or( ,the cursor will reappear to the interface , and the setting of the
parameters of the detector can be continue .
Given priority alarm function, when the fire alarm controller detects fire danger into the state
of "fire", before the fire alarm condition confirmed, please don't do "detector parameter
setting" operation.
Complete detector parameters are modified, shut off the fire alarm system power supply for 1
minute, open the power again, and according to the "detector parameter query" introduces the
check the operation of the detector's parameters are in line with expectations;
To confirm all the deteectors are working in a suitable parameter condition.
EMU project gives corresponding location name for different number of the detector , when
the JB - QB - KCRH (Macedonia EMU project) fire alarm controller output fire alarm, fault
and operating records, the detector number of the records will be showed in the form of place
names.
Following is the place name list of the carrriage detector (LHD heat cable)
Table 4-1 the Mc car (Mc1 and Mc2) detector position name list
Detector nummber
Detector
Physical name
Position neme
The local fire alarm/fault display sample
The other fire alarm/fault display sample
Table 4-2 Mc car (Mc1 and Mc2) LHD heat cable position name list
Heat cable physical name
The local /other fire alarm/fault display sample
Table 4-3 Tp vehicle detector position name list
Detector physical name
Listed of the interface in the subsequent chapters "query information" to the chapter "other car
alarm" , the number of detector of the alarm and fault record , actual displayed as the position
name of the detector in the EMU project , such as "+ 241".
The FIRE] (FIRE alarm record query);

2) [2. The Inquire FAIL] (fault record query);


3) [3. Sensor State] (State data query of the detector).
4) [4. Bus State] (serial communication link road node query);
5) [5. Sensor Param.] (the current value of the detector working parameters query);
The fire alarm controller under the normal monitoring , press "Query" key to enter query
function of the menu options screen as shown in Figure 4-44 .
Press and key to move the current cursor location, press" Enter "key to Enter
the corresponding cursor function.
When the cursor is located in the [1. The Inquire the FIRE], press "Enter" key into the
controller of the fire alarm history query functions.
Figure 4-44 query function menu options interface
The fire alarm information query
The fire history of fire alarm controller of the fire alarm information query JB - QB - KCRH
(Macedonia EMU project) is stored independently by carriage , each carriage can store 200 fire
history.
Records zone of fire alarm save the date and time (year,month,date,hour,minute) of the detector
alarms, alarm source type and name of the carriage and the serial number of alarm detector.
The controller under the normal monitoring , press "Query" key to enterthe Query function of
menu options interface as shown in Figure 4-44 , press "Enter" key to enter carriage choose
interface (the default is the current car number) as shown in Figure 4-45, press and
key to change the carriage number, at the same time name of the carriage will be display
correspondently.
In Figure 4-45 interface, press "Enter" key to Enter a similar fire information display interface
as Figure 4-46(each screen shows three fire alarm record at most, note the "FIRE" character in
the forth line which identification fire alarm record query);
If there is no fire alarm history record in the local carriage fire alarm controller memory, then
the system will enter the information display interface as shown in Figure 4- 47, you can press
any key to exit the query function and return to monitoring the status.
Figure 4-45 the carriage selection interface for fire alarm history query
Figure 4-46 fire history information query display sample
Fire alarm source types include:
Smoke function (SMK), thermal function (TEM), linear heat cable (LHD) or smoke
temperature (ST), temperature sensing and linear cable (TL)sensing source combination (SL,
STL).
As shown in Figure 4-46 of the fire information display interface, if the query of fire history is
more, you can press and key to query more records
Every press of the , records rolling forward by a screen (each screen shows three
historys);
Every press of the , records rolling backward by a screen
In the course of history information query, press "Enter" key, system exit query function
immediately , return to monitoring the status.
Figure 4-47 no fire alarm history information query interface
Events (such as faults and shielding key operations) history query

The fire history of event controller of the fire alarm information query JB - QB - KCRH
(Macedonia EMU project) can be stored independently by carriage , each carriage can store
200 fire history.
Records zone of event save the date and time (year,month,date,hour,minute) of the detector
alarms, alarm source type and name of the carriage and the serial number of alarm detector.
Each controller can store the machine detector fault, key operations such as blocking and
reset ,and can also store other machine (can online) detector failure, but don't record other
machine key operations.
The controller under the normal monitoring , press "Query" key to enterthe Query function of
menu options interface as shown in Figure 4-44 ,press orto let the cursor at the
position of 2.Inquire FAIL, press "Enter" key to enter carriage choose interface (the
default is the current car number) as shown in Figure 4-45, press and key to
change the carriage number, at the same time name of the carriage will be display
correspondently.
Figure 4-48 the carriage selection interface for event history query
In Figure 4-48 interface, press "Enter" key to Enter event information display interface as
Figure 4-49(each screen shows three event alarm record at most, note the "FALE" character in
the forth line which identification fire alarm record query);
If there is no event history record in the local carriage fire alarm controller memory, then the
system will enter the information display interface as shown in Figure 4- 50, you can press any
key to exit the query function and return to monitoring the status.
Figure 4-49 event history information query display sample
Figure 4-50 display sample of event history information query without any record
Here are three kinds of historical events records recorded by the fire alarm controller of the JB
- QB - KCRH (Macedonia EMU project) :
Detector fault alarm, deadened the noise of the machine and the reset operation of the machine
under the alarm condition , the mask operation of the machine detector .
As shown in Figure 4-49 line 3 show on April 10th, 2014, 12:
34 blocked the 4 # detector which administrated by Mc1 carriages .
Among them, the detector fault alarm source types include:
Communication failures (COM), smoke function (SMK), thermal function (TEM), linear heat
cable (LHD), other fault source or their combination (ST, SL, STL, TL).
Event regarding deadened the noise of the machine and the reset operation of the machine
under the alarm condition include:
Deadened the noise of panel (BELL1) and effective input terminals (RBL) sound (BELL2),
panel reset (RESET1) and effective input terminals (RST) reset (RESET2).
As shown in Figure 4-49 of the fault information display interface, if the query of fire history is
more, you can press and key to query more records
Every press of the , records rolling forward by a screen (each screen shows three
historys);
The detector queries
The controller under the normal monitoring , press "Query" key to enterthe Query function of
menu options interface as shown in Figure 4-44 ,press orto let the cursor at the
position of 3.Sensor State, press "Enter" key to enter The detector queries interface,the
LCD screen as shown in Figure 4-45,display the The information of detector query of the 1#
and 2# dector.
A probe link number, type, the current state (normal/fire/fault), smoke sampling value,
temperature sampling value, linear heat cable samples values and probe version number.
When the corresponding detector is not connected to the serial communication bus loop
detector, the state corresponding to 0.
Figure 4 - 51the first of the 51 detector status query interface
Before operate the detector status query,please confirm the fire alarm systm is complete,as
shown in Figure2-5means that the controller and the administrated dector form a right
communication loop.

Mc1 and Mc2 type carriage [3. Sensor State] contains 4 screen interface, and Tp model
carriage [3. Sensor State] contains 2 screen interface, press and or ( and
( key can track the status of detectors with different number.
Through [3. Sensor State] query function, can accurately understand the fire alarm controller
detectors State , each detector working status, the type of each detector (smoke/smoke
temperature).
In Figure 4-51 and Figure 4-52 display interface, press "Enter" key to return to the main
monitoring interface.
Figure 4 - 52 the first of the 51 detector status query interface
The bus status query
The fire alarm control JB - QB - KCRH (Macedonia EMU project) under the normal
monitoring , press "Query" key to Enter Query function of the menu options interface as
shown in Figure 4-44, press or key to make the cursor in the [4. Bus State]
position, press "Enter" key to Enter the fire alarm system has the function of serial
communication link road status Query, then the system into something similar to which are
shown as Figure 4-53, Figure 4-54, Figure 4-55, Figure 4-56 ,the display inteface of the node
number and link information ;
Press any key to exit the query function, return to monitor state.
Figure 4-53 bus status query interface (Mc1 type carriage:
Loop normal)
port disconnect)
In the bus status query display interface, according to the different car number (i.e., type/name)
shows that corresponding to the number of detector, if the bus loop access more number of
detectors, may be ignored part of the probe.
Figure 4-55 bus status query interface ( port disconnect)
Figure 4-56 bus status query interface (open loop)
Detector parameter query
the fire alarm control JB - QB - KCRH (Macedonia EMU project) under the normal monitoring
, press "Query" key to Enter Query function of the menu options interface as shown in Figure
4-44, press or key to make the cursor in the 5.Sensor Param. position,
press "Enter" key to Enter the detector parameter value Query function, then the system into
something similar to which are shown as Figure 4-57, the detector parameter information
diplay interface
Each LCD display 1 detector working parameters, press the key can enter the next or the upper
number of detector parameter query display interface, as shown in Figure 4-58 for 2 # detector
working parameters display interface.
The first line of detector parameters query interface display including (4-57, for example):
The probe type:
Smoke function (SMK), thermal function (TEM), heat cable (LHD) or their combination (TL)
ST, SL, STL,
Detector serial communication rate (range of values:
This value must be consistent with the communication rate of fire alarm controller.
Smoke detection parameter value (S = 50/100).
The internal gain function parameter values (G = 50).
Figure 4-57 detector parameter information display (01 # detector)
Parameters shown in the line 2, 3, 4 in the detector parameters Query interface is familiar with
the detector parameter setting interface , as described in "detector parameter setting";
the only difference is it also shows the current number of sensor and controller communication
port type and path number in row 3(as shown in Figure 4 - A01 in 57:

Said # 01 detector and controller of A port, path = 1);


line 4 also shows the version number of the detector (as the V2.1 shown in Figure 4-57. )
For the closed detector, the query interface display values of its parameters are usually is 0.
As shown in Figure 4-57 and Figure 4-58 detector parameter information display interface,
press the "Reset" or "Enter" key to exit the query function, return to monitor the status.
Before operate the detector status query,please confirm the communication loop between the
controller (SDCU) and the detector is complete,to ensure that the system is complete
Otherwise, may not be able to timely and accurate queries to the parameters of the detectors
with certain numbers.
After the detector which is arranged in the fire area perceive fire hazard, the fire signal
transmitted through serial communication bus loop fire to thw alarm controller, the controller
automatically determine whether the fire alarm is for the first time.
If it is the first time alarm,then to confirm the fire signal firstly(avoid external disturbance).
After confirmed by the cycle test, if the site is still a fire alarm signal, the screen immediately
as shown in Figure 4-59 ,the display format of alarm information, and at the same time start the
buzzer sends out the continuous fire flute (whisper...
), automatically open the LCD back light, panel "fire" (red) light is normally on, at the same
time, the fire alarm output effectively (namely the relay or absorption, the corresponding
contact FIRE1 connected with 110 v +);
And fire alarm record information saved to permanent memory storage area accordingly, for
future inquiry.
Figure 4-59 local carrriage alarm display interface
The number of fire alarm
Name of the carriage
Figure 4-59, there shows the carriage name and related information, item 1 says the number of
alarm of the current cariage, then the carriage name, prompt characters and the mark regarding
"mute";
Information in line 2 to 4 regarding the alarmed detector:
The first row shows the dectector number,the second row shows fire source wieh is detected
earliest by the detector.
Fire smoke function - SMK, thermal function of fire - TEM, the linear heat cable fire - LHD,
or the possible combinations between them:
ST, SL, TL, STL), the third row shows the date of the alarm(month- day- year- time- minuute).
When fire alarm controller conFigured to Mc1, Mc2 carriage ,the # 4, # 5 or # 6 dector which
under the jurisdiction detects fire, the "driver room fire alarm output" of the controller is
effective (namely the relay tracts gathers, the corresponding contact FIRE2 connected with 110
v +).
The "alarm output of the driver's room "of other carrriage will not act.
In a state of fire alarm, the status of each output port of the fire alarm controller as shown in
table
4-4.4-4, it only show the output of each port in fire alarm status, if the controller exist
In table
detector fault at the same time, the corresponding port state will change with the description in
table 4-4.
Table 4-4 local carriage controller output port state fire condition
Name of the port
Electric logo
Status
Connection is suggested
Fault output
FAUL with 110V+ through
Relay tracts gathers
Fire alarm output

FIRE2 with 110V+ disconnected


Rely release
Fire alarm controller in a record, always transmitted from the detector to the fire source of the
controller firstly to start generating records.
The fire source is the earliest on which detected by the detector!
After the controller alarms, if the detect source of the same detector change;
the fire alarm record of the fire alarm controller , in turn, generate a number of different types
of fire source.
Such as:
detector 1 report to the fire alarm controller at a monent that the smoke function detected the
fire hazard alarm, then the fire alarm controller sent out the fire alarm , and generate the fire
alarm record of the smoke (SMK) function ;
Then, may be due to the existence of the fire, the environment makes the temperature which
tested by the detector temperature sensors is also reach to the condition of reporting a fire
alarm , thus send alarms to the controller's heat function.
When the no. 1 detector is in temperature alarm, if the alrarm form the fire smoke detector
function 1 still not disappeared, the controller will produce smoke and heat function (ST, SMK
+ TEM) fire alarm record;
At this point, the LCD screen displays the latest detect fire type, namely according to display
the ST type.
For the detectors with same number, no matter how many different types of fire alarm records
are produced, the LCD interface display only display the latest record.
Other historical records can be reviwed through the query function .
In the process of fire alarm display, in case there are more than 3 sensor
Or press (and (to accelerate the move
After pressing Mute, the screen will display as shown in Figure4-60 (add display marks--noise reduction mark in the first row of LCD screen)
Meanwhile, the controller closes the sound, keep the fire alarm indicating lamp lighting on,
and generate a panel noise reduction historical record (BELL1) in event historical record zone
Figure4-60 Fire alarm display interface of the compartment (noise reduction)
fire alarm frequency
Noise reduction mark
Controller storages as many as 200 fire alarm records in each compartment, when the records
exceeds 200, the controller will automatically use the newest fire alarm record to cover the old
Each controller can storage 600 fire alarm records in 3 compartments
Before fire alarm occurs, in case of the system under failure alarm status, the system closes
failure alarm display, lights on the failure indicating lamp (the yellow lamp), displays fire alarm
information and at the same time opens fire alarm sound
Fire alarm sound can be reduced by pressing Mute, without effects on the fire alarms of
other sensors
In case of improper contact or open-circuit and short-circuit failure between the detector and
the controller, or the controller is in failure connection with the detector, or the internal failure
of the detector (such as the open-circuit of the temperature sensor), the fire alarm controll gives
off failure sound, "failure" yellow indicating lamp is on, and LCD interface displays the
location of the failure alarm (the serial No. of the detector) or failure alarm time.
When the fire alarm system detects the failure of the sensor, the screen immediately display the
failure infrmation in the format as shown in Figure4-61, and start hummer to gives off
intermittent hummering

Automatically start the backlight and failure indicating lamp of the LCD screen, meanwhile,
set valid the failure linage output (relay release, disconnect the corresponding contactor FAUL
and
110V+)
Store
the records into the corresponding storage zone of the non-leak memory for future
inquiry
As in Figure4-61, the first row shows the name of the compartment and related prompt
information, among the first item is the quantity of the current failure alarm of the
compartment, and the item is followed by the name of the compartment, related prompt
information and the sign "whether to reduce the noise"
Alarm detector information is shown in row 2 to row 4
In the first row is the serial No. of the detector, and failure sources of the detector in the
second
Smoke sensoring failure--SMK, temperature sensoring failure--TEM and comunication
failure--COM, in the thrid row is the time of alarm (month-date-year-hour-minute)
When the fire alarm control stands under failure status, the conditions output ports will be as
In table 4-5 only represent the port output under failure status, in case the controller has the
detector fire alarm at the same time, the conditions of the corresponding ports will change from
the description in table 4-5
Failure alarm frequency
Figure4-61.Failure display interface in the compartment
Table 4-5 The conditions of the controller output ports status under failure status in the
compartment
Failure alarm sound of the JB-QB-KCRH (Macedonia EMU project) fire alarm controller is
different from the sound of power on reset; on-site personnel and equipment maintenance
personnel shall be required to be amilar with the sounds.
In the process of information display, if the alarm information exceeds the capacity of the
screen, the system will move up by a line automatically every other 2s.
After pressing Mute, the screen displays as shown in Figure4062 (in the first row of the
LCD screen add the mark of "noise reduction"
At the same time, the controller closes the sound, lights on the failure indicating lamp and
send noise reduction information outside
The controller can store as many as 200 event records of each compartment (the key
operations like detector failure, shielding and reset), when the records exceed 200, the
controller will automatically use the new failure records to cover the old.
Each controller can store 600 event records of three compartments
Fire alarm controller can constantly detect the detector while the detector is under failure
condtion; only by eliminating the failure of the corresponding detector, the controller can
automatically return to monitoring status.
Figure4-62 Failure noise reduction display interface of the compartment
In case one part is already giving off failure alarm, fire signal comes from another part, the
"failure" indicating lap will light on and display the location of the fire alarm, thus the fire
alarm sound will replace the failure sound.
As shown in Figure2-5, fire alarm controller is in end-to-end connection with the detector
under its control to form a closed communication loop
When the general parallel communication bus breaks at certain point (such as the detector plug
or ceertain point on the communication cable) , so the general communication wire can no long
close
When the controller circle detection communication bus breakage for certain period of time
(10s or so), the controller will display the failure of "general loop wire breaks", at that time, the
"failure" indicating lamp on the panel will be flashing (0.3s on ad 0.3s off)
bus loop failure is just an abnormal operation status of the general parallel communication
wire; when the communication loop wire breaks at only one point, the controller can still finish
data communication with the detectors, with the only result of lower redandunt communication
effects.

Therefore, "bus loop breakage" must be eliminated as soon as possible


Under "bus loop breakge" status, use 4.Bus Stateinquiry function to check the rough
location of the breakage
As shown in Figure4-56, the comunication between 01# and 02# detectors disconnect; as
shown in Figure4-633, the interface displays the general communication wire disconnect
between 01# and 02# detectors
When certain detector separates from the general parallel communication wire, the control will
report the communication failure of the detector and generate failure event record; the LCD
screen will show like in Figure4-64, and at the same time, output the failure is output, release
the relay releases, and start the hummer to give off intermittent hummering.
Automatically start the backlight and the failure indicating lamp of the LCD screen
Figure4-64 Detector communication failure display interface
3 Macedonia EMU project fire alarm controllers connect by CAN communication bus; when
the alarm arises from other compartment, the controllers in other interconnected compartments
will get into alarm status at the same time
The alarm from other compartments will not affect "failure output" of this compartment, and
the port status of "fire alarm output" and "fire alarm output in driver's cab"
In addition, the alarm from other compartment also affects the 'failure" and "fire alarm"
indicating lamps on the panel
fire alarm from other compartment
When the fire alarm system detects the fire alarm on the sensor, it delays for 1~2s, in case of no
artificial reset, the controller send out the fire signal through CAN communication network
Other fire alarm controllers on the communication bus receive the information from the fire
alarm compartment, they immediately display the alarm content and start the backlight of the
LCD screen as shown in Figure4-65, the "fire alarm" indicating lamp keeps on and send fire
alarm for other compartments.
At the same time, the fire alarm system will store the records into the corresponding storage
zone of the non-leak memory for future inquiry
The fire alarm from other compartments will not affect the fire alarm output in this
compartment
When the fire alarm controller detects that the fire alarm is beyond artificial interference to
remove, the fire alarm sound, fire alarm indicating lamp and the display will hold until the fire
alarm controller finishes reset operation.
While non-fire alarm controller is in reset or noise reduction operation, the controller does not
send noise reduction information
That's to say, non-fire alarm controller will not be able to reset the fire alarm behavior of the
fire alarm controller
Fire alarm signal of the fire alarm controller can only reset in its own compartment
Non-fire alarm controller receives the sound of the fire alarm controller, it removes the fire
alarm from other compartment at the corresponding serial No., in case of alarm of any other
controller involved, remove the alarm sound
Figure 4-65 Fire alarm display interface in other compartments
Figure 4-65 Fire alarm display interface in other compartments (noise reduction)
After non-fire alarm controller receives the reset information from alarm controller, it removes
the fire alarm information of the fire alarm controller at the corresponding serial No., including
the information displayed in the compartment.
In case of on alarm from any other controller at this time, the compartment can remove the
alarm sound
Fire controller keeps silent to the noise reduction and reset information from network
Fire controller keeps silent to the alarm information from other compartments

Alarm from other compartments


When the fire alarm controller detects the failure of the sensor, it will send the information by
CAN bus connection, and when other fire alarm controllers on the communication network
receives the failure information from other compartments, it immediately display the failure
content in the format as shown in Figure4-67, starts the backlight of the LCD screen and the
hummer and lights on "failure" indicating lamp
In Figure4-67, the first item of the first row represents the quantity of failure alarm from other
compartments, and is followed by related prompt and the mark "whether for noise reduction or
not".
From row 2 ~4 are the number of the compartment that gives off alarm and the information of
the detector
In the first row is the name of the compartment, in the second row is the number of the
detector, while the failure alarm source type are listed in row 3 and alarm dates on row 4
(month-day-year), in row 5 is the specific time of the alarm
Failure alarm sources include
Communication failure, smoke sensoring failure, temperature sensoring failure, linear
temperature sensoring cable and their combination, or OTH (other function alarms)
Figure4-67 failure display interface in other compartments
Failure quantity
While displaying the information, in case the failure information exceeds the capacity of the
screen, the system will move up a line every other 2s, or press (and(by hand to
accelerate the movong rate
After pressing Muteon the failed controller, the screen will display as shown in Figure468, close the spund, but the remote instruction to hold the operation status will go invalid, and
the nise reduction information will be sent out
Similar to the fire alarm from other compartments, press MuteReseton the
controller displaying the failure information of other compartments, the key function only work
on the controller, and bever send out the data frame information through CAN bus connection
Figure4-68 failure noise reduction display interface of other compartments
JB-QB-KCRH fire alarm controller has set its priority as below, in case of the higher level
alarm information, the lower level alarm will not display on the current screen
Fire alarm information in this compartment
Fire alarm information in other compartments
Failure information in this compartment
Failure information in other compartments
When JB-QB-KCRH(Macedonia EMU project) fire alarm controller gets into fire aalrm or
failure alarm status of its own compartment, press Reset, the controller will get into reset
operation (as shown in Figure4-69)
Under the status as shown in Figure4-69, press Enter, the controller begins reset
operation, the interface will display for 2s as shown in Figure4-70
In case no key operation on the panel for 60s, the controller will go back to alarm display
screen automatically, thinking no need for reset operation.
Figure4-69 Reset operation confirmation interface
Figure4-69 Prompt interface for successful reset operation
After the successful reset operation, the fire alarm or failure controller in the compartment
restart the detector, closes all the alarm indicating lamps and sound, sends reset key data frame
through CAN communication port, and generates a reset peration record in the machine, and
the system gets back to monitoring status

When JB-QB-KCRH controller gets into the fire alarm or failure alarm status of other
compartments, pressResetwill get the system to remove the fire alarm or failure
information from other components, close the hummering of the controller but never sends key
data frame through CAN communication ports, and the controller system gets back to
monitoring status
Figure4-71 Reset operation failure prompt interface
Under the status of either fire alarm or failure, press Resetcan get the controller
temporarily close the power of the detector (2s or so) to get the smoke spread out from the
detector, and also to make sure the reset of the corresponding functions of the detector
After closing detector power, controller will restart the detector and get back to normal
monitoring
status
JB-QB-KCRH(Macedonia
EMU project) fire alarm controller supports remote reset function,
make short-circuit of the RST of the controller plug and 110V+ electronic points for 1s (or use
the externally connected the light-touch key at the father end), the fire alarm controller gets
into reset status
The function of RST and 110V+electronic points is the same as that theReset, and there is
a true "reset" significance when only when the system has alarm
When the system is under the normal monitoring status, LCD screen displays the interface as
shown in Figure4-2, that's to say the controller never detects the alarm nor the failure
and never in setting operation display interface, nor in inquiry operation display interface
At that time, opress Resetwill result in no operation effect
Resetcan work for the fire alarm system only when the controller is under alarm or failure
status
When JB-QB-KCRH(Macedonia EMU project) fire alarm controller receives fire alarm (or
failure) in the compartment, system hummer will give out corresponding alarm sound
The hummering can be closed by pressing Mute and the key data frame can be sent out
through CAN communication ports, and a reset operation record will be generated in the
machine
After pressingMute, the identifications will be displayed in the first row of LCD screen
(such as Figure4-60,4-62, the "noise reduction" mark on the upper right corner), at this time,
the system close the alarm sound without any effects on new alarm, the alarm indicating lamp
is on and the alarm records display status holds the same
JB-QB-KCRH(Macedonia EMU project) fire alarm controller supports remote noise reduction
function, and make short-circuit for controller plug RBL, 110V+ electronic points (or using
externally connected light-touch key at the father end), and the fire alarm controller gets back
to noise reduction status
The function of RST and 110V+electronic points is the same as that theReset, and there is
a true "reset" significance when only when the system has alarm
Tool
1) cross screwdriver
2)sleeve
Installation procedure
The installation of fire alarm controller
Switch off the controller power
Install the connectors X1 and X2, screw up the earthing screws
Put the controller at the installation hole
Screw into the installation hole on the controller panel with cross screwdriver
The installation of the detector
Switch off the controller power
Screw up the bolts and nuts in the four installation holes of the detector with spanner and cross
screwdriver
Connect the connectors in the row of Y1 and Y2
Preparation before commissioning
Get familiar with smoke alarm system

Read carefully the user's manual below and grasp the related operation methods
' JB-QB-KCRH user's manual'
Get familiar with on-site application structure of the fire alarm system
In case of a wrong on-site application structure of the fire alarm system
items to be checked before on-site test of the fire alarm system
Check the following items before on-site test of the fire alarm system
1) on-site wiring check of the smoke alarm system to make sure no short-circuit or open circuit
of the wire in the compartment
Check if the signal wire is the same as the two plug (one male and one female) on each of the
sensors join together
Measurement of the on-site power supply for smoke alarm system, measure the "110V+" ,
"110V-" voltage of the plug of the on-site fire alarm controller to make sure the smoke alarm
system meet the requirement of the main controller
It must make sure the same coding address of the detectors on the same communication bus
(the coding address of the detectors in the same compartment cannot repeat
System power supply test
The external wiring connecting fire alarm controller mainly includes
1)power supply for fire alarm controller
2)I port and the power supply for the detector, and the parallel communication bus
4) fire alarm and failure linkage output
5) remote reset input
Turn on the power of the fire alarm controller (panel power switch), the system gets into
hardware self-checking
Set the corresponding number of the compartments
Set>>2.Set SDCUset the number for compartments
implement detector automatic numbering operation after the first use or replacement of the
detector
Implement automatic numbering operation
Joint test and commissioning of the fire alarm controller and the detector
After the power-on self-checking of the fire alarm controller, it automatically gets into fire
monitoring status
Meanwhile, the fire alarm controller starts the power of the detector, and review the operating
status and daat collection of each detector
In case of no detector alarm after 30s of the power of the fire alarm controller, it suggests the
parrallel communication function is normal between the fire alarm controller and the detector
Note: fire alarm controller port parameter (open or close certain detector) shall be the same as
the communication address of the detector
If the detector of the fire alarm controller is allocated as below:
Open 1#, 2#, 3#, 4# detectors , close 5#, 6#, 7#, 8#, 9# detectors
There must be 4 detectors on the parallel communication bus, and their communication address
are respectively 1#,2#,3# and 4#
In case there are 5# and 6# detectors on the communication bus, the fire alarm controller will
neglect the failure and fire alarm of the detector
Although the communication physical layer between the fire alarm controller and the detector
must abide by national and international standards, the communication bus must be the internal
on-site bus exclusive for smoke alarm system
Any other devices are not allowed to connect to the bus of the smoke alarm system on site
System alarm function test
1) failure alarm function test

2) confirm fire alarm controller under monitoring status


Take off one of the communication wires of the detector (such as 1#), and join the two pull-out
plugs Y1/Y2, to avoid the detector on the follow-up wire being pulled out from the system
3) the system gets into 1# detector failure status
The failure indicating lamp corresponding to No.1 detector turns on, and the hummer begins to
give off intermittent hummering
Meanwhile, "failure linkage output" of the fire alarm controlled--dry contact points signal
(contact points disconnect) can be observed by TCMS system
4) Fire alarm controller detects the failure of the detector, and only by eliminating the failure
of the corresponding detector, the controller can automatically return to normal monitoring
status
To thoroughly check on-site fire alarm system, conduct the above failure alarm function test for
each of the detectors
2 fire alarm function test
2) smoke fire alarm
Use "smoking device" to make aerosol spraying over certain detector (such as 2# detector),--only operable under the allowed circumstances on site
temperature fire alarm
Use "heating device" to heat up certain detector--operable only under allowed circumstances
on site
3) the indicating lamp of the detector turns on
4) the system gets in fire alarm status
The fire alarm indicating lamp (the red lamp) on the crate panel corresponding to the detector,
meanwhile, start the hummer for constant hummering
Meanwhile, "failure linkage output" of the fire alarm controller--dry contact points signal
(contact points close) can be observed by TCMS system
Fire alarm controller gives fire alarm, as thealarm removes, the controller must be restarted by
reset operation on fire alarm controller panel or at remote reset contact, or disconnecting fire
alarm controller power
Or else, fire alarm controller will keep the indicating lamp on and continuously give alarm
siren, although the alarm has been removed
To complete the exam of the field fire alarm system, fire alarm funtion test needs to be done on
each detector as per the steps above.
Table 5-1. Recording of the JB - QB - KCRH fire alarm controller field testing and debugging
data
Train number
Date of test
Year
Month
Day
Carriage Type:
Detecor configuration:
Function
Fault
Indicator light
Buzzer
Mute
Reset
Information
Storage
Test results (qualified with "tick", unqualified with "x")

Detector number
Testing, testing project
Wiring status
somke sensing/fire alarm
temperature sensing/fire alarm
Remote output
Remote input
Driver room fire alarm
Passenger compartment fire alarm
The recorder of the test:
(Signiture)
Exit the debugging
After complete the test content above,reset the system and back to the normal monitor
interface,it means the debugging is completed.
Maintaince
Parts
Maintaince content
Working hours
Maintaince cycle
Controller
Check the cable
Check the systm working status
Function test
Clean dust of the equipment surface
Replace the new accessories
Returned to the factory to calibrate
Make sure the correctness of the fire alarm controller configuration parameters (i.e. whether
the numbered fault detector probe is a real connection detector address, for example, the
detector number 3 of the fire alarm controllor report fault, firstly confirm whether the carriage
needs the detector number 3 and whether the bus is connected to the No 3 code address of the
detector), and test will be done according to the method as shown in Figure 7-1 after
confirming.
In addition,if the TCMS monitoring system reports the fault of the fire alarm system,but the
fire alarm controller of the fire alarm system under the jurisdiction reports no failure, it is need
to check connection line between the TCMS and the fire alarm controller.
Figure 7-1 Troubleshooting process of the JB - QB - KCRH fire alarm system
Record the address code of the fault reported detector
Using heater or smoke test equipment to simulate the fire alarm environment
Detector alarms
The host alarms?
Check the communication line between the dector and the host
Unplug all the connector on the nodes of the bus, use the multimeter test the line
There is short circuit, open circuit of the line?
Eliminate the fault of the line ,reconnected and test again
Inner fault of the detector
Replace the detector
Detector misstatement process flow is shown in Figure 7-2.
Figure 7-2 The maintenance process of the JB-QB-KCRH fire alarm system
Record the address code of the false fire alarm reported detector

Exam if the fire hazard hidden trouble exsists in the detector environment
The temperature and smoke
Temperature is too high?
The smoke?
The hidden trouble of fire hazard at scean
System alarms - equipment is normal
Phillips screwdriver
Sleeve
Disassemble Step
The removal of fire alarm controller
Using the phillips screwdriver to unscrew the set screw of the panel
Take out the controller
Unplug the connector X1, X2, and screw out the grounding screw
The removal of detector
Pull out the " Y1"," Y2 "two rows of socket
Use wrench with the phillips screwdriver, screw out the screws and nuts of the four mounting
holes of the detector .
Take out the dectector
Carrie out the whole machine replacement of the self-check part
Carrie out the whole machine replacement of the failure detector
Plug the connector X1, X2, and screw the grounding screw
Place the detector on the installation location
Using the screwdriver to unscrew the set screw of the panel
Rotate the detector to the installation location
Use wrench with the phillips screwdriver, tighten the screws and nuts of the four mounting
holes of the detector .
Connect the " Y1"," Y2 "two rows of socket
Testing system according to the commissioning procedures, to ensure that the system function
is normal.
Blower gun
YHCS detector tester
Figure 8-1 blower gun
Figure 8-2 YHCS detector tester
Wearing parts
Inapplicable
Spare parts list
Unit
Suppliar
Fir alarm controller
Piece
In order to distinguish with other projects, increase after Duo "M"
Heat smoke compound detector
Piece
Temperature sensing cable (5 m, zone 2 for terminal row)
Stick
Detector connector (7 pin type plug)
Detector connector (7 pass plug)
Fire alarm controller connector (10 pin type plug)
Fire alarm controller connector (13 pass plug)

When the components are ageing and the performance indicators are decreased ,it is not in
conformity with the basic requirements of using.
Beyond the product life cycle;
Equipment with badly damage and is unable to be repair
Users can scrap the products which the manufacturer is unable to repair.
User can dispose the discarded equipment according to the differeent use value , and also can
submit the discarded products to electrical and electronic equipment recycling station.
During the transporting and storage process of the dector of the JB - QB - KCRH fire alarm
system, pay attention to:
Anti-static, moisture-proof, waterproof, antirust, etc;
Avoid rain, blisters, high temperature.
Transportation ways like road transport, rail transport, water transport, and air transport are
allowed to be used in the transportation of fire alarm controller and detector of the JB - QB KCRH fire alarm system allows .
Product must be shipped with package.
Appropriate storage environmen for the fire alarm controller and detector of the JB - QB KCRH fire alarm system:
Storage temprature:
Storage humidity:
Abbreviation
Full english name
Chinese name
The smoke detection control unit
Smoke temperature detector
Linear thermal detector
When unpacking the case,check the goods to see if there were any breakage phenomenon
during the transportation, and at the same time, check the shipping product nameplate to
confirm that if the product's type and material nukmber are in accordance with your order.
If you have any question, please contact the company as soon as possible.