Вы находитесь на странице: 1из 2

PT.

BERCA MANDIRI PERKASA

BP625
Open Type

SPECIFICATIONS CUMMINS ENGINE


Engine Model: KTAA19-G6A
Engine Speed: 1500RPM

BP625S

PRtME

Canopy Type

-kW

610kW

-HP

829HP

STANDBY

Type .. .. ...... .. .... .. ...... .... .. .... .. ...... ...... .. In-Line, 4 cycle, water cooled , Turbo
Charoed . air~air aftercooled
Number of Cylinder ..............................6
Bore x Stroke ..................................... 159 x 159 mm
Displacement

.... 18.9 L

Compression Ratio ......

.. .. 13.9 : 1

Fuel Injection Pump ..........

... PT

Governor -----.EFC

Injection Pump

Electrical Governor

Steady SpeedDroop ............................ </= 1%

"The above photo is far demonstration only. Real product may look different.

Lub. Oil Grade .................................... 15W40-CF4 Upgrade

GEN SET OUTPUT


Frequency:
Voltage:
Engine Speed:

Lub. Oil Capacity ................................ 50 L


Cootan1 Capacity

SO Hz
400VAC
1500RPM

.................. 106 L (Engine)

Cooling ........ ...................................... Forced Water Cooling Cycle


Flywheel/Flywheel Housing .................. 14
Dry Weight ..

I SAEO#

.. .... 1820 kg

Fuel Consumption at full load (prime) .... 201 kg/ h

*Remark: Please consult your local supplier for other voltages

PRIME

STANDBY

ALTERNATOR

SOOKW

550KW

625 KVA

688 KVA

Manufacturer: STAMFROD
Country of origin: CHINA
Model: HCl544FS

BERCA POWER GENSET


PERFORMANCE GUARANTEED
Standard series and Weather and Sound Proof Canopy series are designed, Manufactured
and tested under strict quality control procedure, to ensure top perfonrance
at all times.

Control System .............. ............ ....................... Self Excited


Voltage Regulation

...... .+/-0.5 %
.. ............ Class H

Insulation Class ... ................. .

.. ...... .IP23

Protection ......

Rated Power Factor .................................... ........ 0.8


PACKAGED ACCESSORIES
Generator set units are packaged with an1~vibration system, advanced control panel,
starting system, synchronizing panel, base fuel tank and other accessories v.flich rrake
ready for power station.
BASE SKID
Standard built-in anti-vibration system - bonded rubber units fitted as standard vvhich
eliminate the need for rubber mats or spring mountings.

Stator Winding ..................................... .

Winding leads ..

motor-or heat exchanger optional.

. ................... 12

Waveform Distortion .

.. ...... No Load <1.5%

Telephone Interference ....................................... THF < 2%


Maximum Overspeed ......................................... 2250 rpm
Seering ..

.. .......Single
.. ................. 1585 kg

Weight .... ..
COOLING SYSTEM
Set-mourn radiator for ambient te,,..,.,rature of 50C standard; Rem:Jle Tadiator with fan

. Double Layer Lap

.. ....... 2f3

Winding Pitch ................. .... .... .

GENSET SPECIFICATIONS
Dimensions : 3750 x 1960 x 2360 mm (Open Type)

STAMFORD ALTERNATOR

5100 x 1800 x 2500 mm (Canopy Type)

Dry Weight : 4300 kg (Open Type)


5500 kg (Canopy Type)

APPLICATIONS
Alternators are designed to be suitable for typical generator applications, such as: backup,
standard production , C<>1J<'fleration, rental, telecommunications , etc.
STANDARD OF COMPLIANCE
Alternators oonform to the main international standards and regulations~
IEC60034, NEMA MG1 .22, ISO 8528, CSA, CSA/UL, etc.
Alternators are designed, manufactured and marketed in an ISO 9001 environment.

Sound Level : 97dBA (Open Type)

71 dBA (Canopy Type)

Ambient Temperature : 25.C


Altitude : 300 m
Relative Humidity : Below 80%

CONDITIONS AND DEFINITIONS


Prime Power Rating:

TOP OF THE RANGE ELECTRICAL PERFORMANCE


Class H insulation
Standard 12-wire re-ronnectable winding, 2f3 pttch , type number 6
High efficiency and motor starting capacity.
Total harmonic content <2.5%

Prime pcmer rating is applicable for unlimited number of operation hour per year in
variable load condttion . Variable load should not exceed 70%of Prime Power in
average of total operation. A 10% overtoad is allowed for 1 hour in every 12 hour of

consecutive operation.
Standby Power Rating :
Continuous running at variable load for emergency povver. No ovel1oad is allO'Ned .
Standard referred:
Engine ratings are in accordance with IS03046 or BS5514.
Fuel Consumption:
Fuel consumption is defined under 100% Prime/Standby Rating .
Gensel Ratings:
Gensel is rated at 400VAC/ 50Hz.
Sound Level:

Sound level is measured at 7 m.

STANDARD/OPTIONAL SCOPE OF SUPPLY


GENSET

STANDARD

Cummins CCEC Diesel Engine

fectric Governor
Stamford AC Alternator
Mild Steel Skid Base
Set Mount Anti-vibration Isolators
Control Panel and Main Breake

COOLING SYSTJ:M

STANOARD

Set Mount Radiator


Remote Radiator

CONTROL SYSTEM

STANDARD

DSE3110
DSE7220

ACCESSORIES

STANDARD

Industrial Silencer
Residential Soencer
Flexible Bellaw
Maintenance ~Free l!attery
Lead Acid Battery
Battery Float Charger
Block Heater

Coolant Heater
Anti-condensation Heater

S.-ECT-RICAL

STANDARD

3P MCCB and Breaker Panel

Parallel Panel

Fuel Tank
Base Fuellank
Daily Fuel Tank

STANDARD

OPTION

Heat Exchanger

ATS Panel

OPTION

GENSET CONTROL MODULE DSE3110

OPTION

OPTION

OPTION

The DSE3110 can be utlHsed as a Manual or Auto Start Module


for single gen-set applications and forms part of DSE's next
generation of control modules. The module has been designed
to work with electronic and non electronic engines providing
advanced engine monitoring and protection features.
The DSE3110 includes a bacldlt LCD display which clearly
$hows the status of the engine at all times. The module
monitors englne speed, frequency, voltage and run hours and
also displays the warning and shutdown status of the engine.
The module includes six digltal Inputs and four outputs. Two
of the outputs are configurable. The module can either be
pr-0grammed using the front panel or by using the DSE
Configuration Suite PC software.
The module Is available In two variants: Magnetic Pick-up and
Canbus .
CAN- F-0r ~se with CAN~ngines only. Optional frequency (Hz)
sensing from maln AC alternator for gen-set applications .
MPU - For use with traditional (non-CAN) engines only.
Optional frequency (Hz) sensing from main AC alternator for
gen-set applications. Optional Magnetic Pickup speed
sensing.

OPTION

GENSET DIMENSIONS
BP625 Open Type Genset
DryWeight:4200 KG
Srze: 3750 x 1960 x 2360 mm
BP625S Canopy Type Genset
Size:5100 x 1800 x 2500 mm
Dry Weight:5500 KG

The DSE7220 is an Auto Mains (Utility) Failure Control Module.


The DSE722-0 ~ncludes the additional capability of being able to
monitor a mains (utility) supply, The module has been designed
to start and stop diesel and gas generating sets that include
electronic and non-electronlc~gines.

PT. BERCA MANDIRI PERKASA


Jin. Pangeran Jayakarta 149A, Jakarta 10730 - INDONESIA
Phone. +62 21 6006125, 6399190, 6280900,
Fax. +62 21 639919'1
Email. bmp@berca-mp.co.id
www.berca-mp.ro.id

Subsidiary of :

YOUR

TOTAL

PARTNER

PT. ALTR AK 1878

BRANCH NETWORKS:
ASEM REGES (021) 6281241 CIKARANG (021) 89901978 CILEGON (0254) 390678 BANDUNO (022) 87523793 SEMARANG (024) 3544469 SURABAYA (031) 8471978 LAMPUNG (0721) 789976 PALEMBANG (0711) 364453

BANG KA (0717) 439578 JAPIBI (0741) 63408 PADANG (0751) 7052100 PEKANBARU (0761) 567678 PERAWANG (0761) 7052635 lllIDAN (061) 8449978 BATAM (0778) 432412 BALIK PAPAN (0542) 761978 SANGATTA (0549)