Вы находитесь на странице: 1из 5

[root@eir1a tmp]# .

/MegaCli -AdpAllInfo -aALL


Adapter #0
==============================================================================
Versions
================
Product Name
: LSI MegaRAID SAS 9261-8i
Serial No
: SV05002392
FW Package Build: 12.9.0-0037

Mfg. Date
Rework Date
Revision No
Battery FRU

Mfg. Data
================
: 12/06/10
: 00/00/00
:
: N/A

Image Versions in Flash:


================
BIOS Version
: 3.18.00_4.09.05.00_0x0416A000
FW Version
: 2.90.03-0933
Preboot CLI Version: 04.04-010:#%00008
WebBIOS Version
: 6.0-18-e_13-Rel
NVDATA Version
: 2.06.03-0010
Boot Block Version : 2.02.00.00-0000
BOOT Version
: 01.250.04.219
Pending Images in Flash
================
None

Controller Id
Vendor Id
Device Id
SubVendorId
SubDeviceId

PCI Info
================
: 0000
: 1000
: 0079
: 1000
: 9263

Host Interface : PCIE


Number of Frontend Port: 0
Device Interface : PCIE
Number of Backend Port: 8
Port : Address
0
508002000000007f
1
0000000000000000
2
0000000000000000
3
0000000000000000
4
0000000000000000
5
0000000000000000
6
0000000000000000
7
0000000000000000

SAS Address

HW Configuration
================
: 500605b002ed51e0

BBU
:
Alarm
:
NVRAM
:
Serial Debugger :
Memory
:
Flash
:
Memory Size
:
TPM
:
On board Expander:
Upgrade Key
:
Temperature sensor
Temperature sensor

Present
Present
Present
Present
Present
Present
512MB
Absent
Absent
Absent
for ROC
: Absent
for controller
: Absent

Settings
================
Current Time
: 16:53:27 9/25, 2012
Predictive Fail Poll Interval
: 300sec
Interrupt Throttle Active Count : 16
Interrupt Throttle Completion
: 50us
Rebuild Rate
: 30%
PR Rate
: 30%
BGI Rate
: 30%
Check Consistency Rate
: 30%
Reconstruction Rate
: 30%
Cache Flush Interval
: 4s
Max Drives to Spinup at One Time : 4
Delay Among Spinup Groups
: 2s
Physical Drive Coercion Mode
: 1GB
Cluster Mode
: Disabled
Alarm
: Disabled
Auto Rebuild
: Enabled
Battery Warning
: Enabled
Ecc Bucket Size
: 15
Ecc Bucket Leak Rate
: 1440 Minutes
Restore HotSpare on Insertion
: Enabled
Expose Enclosure Devices
: Enabled
Maintain PD Fail History
: Enabled
Host Request Reordering
: Enabled
Auto Detect BackPlane Enabled
: SGPIO/i2c SEP
Load Balance Mode
: Auto
Use FDE Only
: Yes
Security Key Assigned
: No
Security Key Failed
: No
Security Key Not Backedup
: No
Default LD PowerSave Policy
: Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 0
Auto Enhanced Import
: No
Any Offline VD Cache Preserved : No
Allow Boot with Preserved Cache : No
Disable Online Controller Reset : No
PFK in NVRAM
: No
Use disk activity for locate
: No
POST delay
: 90 seconds
Capabilities
================
RAID Level Supported
: RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, R
AID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF lay
out with no span, PRL11-RLQ0 DDF layout with span

Supported Drives

: SAS, SATA

Allowed Mixing:
Mix in Enclosure Allowed
Mix of SAS/SATA of HDD type in VD Allowed
Mix of SAS/SATA of SSD type in VD Allowed
Status
================
ECC Bucket Count

: 0

Limitations
================
Max Arms Per VD
: 32
Max Spans Per VD
: 8
Max Arrays
: 128
Max Number of VDs
: 64
Max Parallel Commands
: 1008
Max SGE Count
: 60
Max Data Transfer Size : 8192 sectors
Max Strips PerIO
: 42
Max LD per array
: 16
Min Strip Size
: 8 KB
Max Strip Size
: 1.0 MB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade
: 0 GB
Current Size of FW Cache
: 431 MB
Device Present
================
Virtual Drives
: 7
Degraded
: 0
Offline
: 0
Physical Devices : 10
Disks
: 8
Critical Disks : 0
Failed Disks
: 0
Supported Adapter
================
Rebuild Rate
:
CC Rate
:
BGI Rate
:
Reconstruct Rate
:
Patrol Read Rate
:
Alarm Control
:
Cluster Support
:
BBU
:
Spanning
:
Dedicated Hot Spare
:
Revertible Hot Spares
:
Foreign Config Import
:
Self Diagnostic
:
Allow Mixed Redundancy on Array :
Global Hot Spares
:
Deny SCSI Passthrough
:
Deny SMP Passthrough
:
Deny STP Passthrough
:
Support Security
:

Operations
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No

Snapshot Enabled
: No
Support the OCE without adding drives : Yes
Support PFK
: No
Support PI
: No
Support Boot Time PFK Change
: No
Disable Online PFK Change
: No
Support Shield State
: No
Block SSD Write Disk Cache Change: No
Supported VD Operations
================
Read Policy
: Yes
Write Policy
: Yes
IO Policy
: Yes
Access Policy
: Yes
Disk Cache Policy
: Yes
Reconstruction
: Yes
Deny Locate
: No
Deny CC
: No
Allow Ctrl Encryption: No
Enable LDBBM
: No
Support Breakmirror : No
Power Savings
: No
Supported PD Operations
================
Force Online
Force Offline
Force Rebuild
Deny Force Failed
Deny Force Good/Bad
Deny Missing Replace
Deny Clear
Deny Locate
Support Temperature
Disable Copyback
Enable JBOD
Enable Copyback on SMART
Enable Copyback to SSD on SMART Error
Enable SSD Patrol Read
PR Correct Unconfigured Areas
Enable Spin Down of UnConfigured Drives
Disable Spin Down of hot spares
Spin Down time
T10 Power State
Error Counters
================
Memory Correctable Errors : 0
Memory Uncorrectable Errors : 0
Cluster Information
================
Cluster Permitted
: No
Cluster Active
: No
Default Settings
================
Phy Polarity
Phy PolaritySplit
Background Rate

: 0
: 0
: 30

:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:

Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
Yes
No
Yes
Yes
No
30
No

Strip Size
:
Flush Time
:
Write Policy
:
Read Policy
:
Cache When BBU Bad
:
Cached IO
:
SMART Mode
:
Alarm Disable
:
Coercion Mode
:
ZCR Config
:
Dirty LED Shows Drive Activity :
BIOS Continue on Error
:
Spin Down Mode
:
Allowed Device Type
:
Allow Mix in Enclosure
:
Allow HDD SAS/SATA Mix in VD
:
Allow SSD SAS/SATA Mix in VD
:
Allow HDD/SSD Mix in VD
:
Allow SATA in Cluster
:
Max Chained Enclosures
:
Disable Ctrl-R
:
Enable Web BIOS
:
Direct PD Mapping
:
BIOS Enumerate VDs
:
Restore Hot Spare on Insertion :
Expose Enclosure Devices
:
Maintain PD Fail History
:
Disable Puncturing
:
Zero Based Enclosure Enumeration :
PreBoot CLI Enabled
:
LED Show Drive Activity
:
Cluster Disable
:
SAS Disable
:
Auto Detect BackPlane Enable
:
Use FDE Only
:
Enable Led Header
:
Delay during POST
:
EnableCrashDump
:
Disable Online Controller Reset :
EnableLDBBM
:
Un-Certified Hard Disk Drives
:
Treat Single span R1E as R10
:
Max LD per array
:
Power Saving option
:
Default spin down time in minutes:
Enable JBOD
:
TTY Log In Flash
:
Auto Enhanced Import
:
BreakMirror RAID Support
:
Disable Join Mirror
:
Enable Shield State
:
Time taken to detect CME
:
Exit Code: 0x00

64kB
4 seconds
WB
None
Disabled
Yes
Mode 6
No
1GB
Unknown
No
No
None
SAS/SATA Mix
Yes
Yes
Yes
No
No
16
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
SGPIO/i2c SEP
Yes
Yes
0
No
No
No
Allow
No
16
All power saving options are enabled
30
No
No
No
No
No
No
60s

Вам также может понравиться