EXPRESS 6503
SHDSL ATM DSU
User Manual
1200296L1
61200296L1-1A
May 2001
Trademarks
Any brand names and product names included in this manual are trademarks,
registered trademarks, or trade names of their respective holders.
To the Holder of the Manual
The contents of this manual are current as of the date of publication. ADTRAN
reserves the right to change the contents without prior notice.
In no event will ADTRAN be liable for any special, incidental, or consequential
damages or for commercial losses even if ADTRAN has been advised thereof as a
result of issue of this publication.
Safety Instructions
When using your telephone equipment, please follow these basic safety
precautions to reduce the risk of fire, electrical shock, or personal injury:
1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink,
laundry tub, in a wet basement, or near a swimming pool.
2. Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
3. Avoid using a telephone (other than a cordless-type) during an electrical storm.
There is a remote risk of shock from lightning.
4. Do not use the telephone to report a gas leak in the vicinity of the leak.
5. Use only the power cord, power supply, and/or batteries indicated in the manual. Do not dispose of batteries in a fire. They may explode. Check with local
codes for special disposal instructions.
6. Never touch uninsulated telephone wires or terminals unless the telephone line
has been disconnected at the network interface.
7. Use caution when installing or modifying telephone lines.
(800) 615-1176
Sales
(800) 827-0807
Post-Sale Support
Please contact your local distributor first. If your local distributor cannot help,
please contact ADTRAN Technical Support and have the unit serial number
available.
Technical Support
(888) 4ADTRAN
The Custom Extended Services (ACES) program offers multiple types and levels
of service plans which allow you to choose the kind of assistance you need. For
questions, call the ACES Help Desk.
ACES Help Desk
(888) 874-2237
(256) 963-8722
Identify the RMA number clearly on the package (below address), and return to
the following address:
ADTRAN Customer and Product Service
901 Explorer Blvd.
Huntsville, Alabama 35806
RMA # _____________
Training
The Enterprise Network (EN) Technical Training offers training on our most
popular products. These courses include overviews on product features and
functions while covering applications of ADTRAN's product lines. ADTRAN
provides a variety of training options, including customized training and courses
taught at our facilities or at your site. For more information about training, please
contact your Territory Manager or the Enterprise Training Coordinator by phone at
800-615-1176 ext. 7500, by fax at 256-963-6700, or by email at
training@adtran.com.
Training
CONTENTS
Express 6503 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Express 6503 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
12
12
13
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SHDSL Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Configuring the Express 6503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
System Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
System Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
System Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
System Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Unit Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
CLEI Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Part Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Firmware Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Bootcode Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
System Uptime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Date/Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
System Config. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Protocol Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
ATM/FR IWF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
ATM Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
ATM Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Maint Port Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Password Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Baud Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Data Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Stop Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
DTE Select/Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
DTE Select (V.35/X.21) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
DTE Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SHDSL Config/Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SHDSL Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SHDSL Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
System Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Upgrade Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Transfer Method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Filename . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Start Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
DTE Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Network Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Appendix A. Navigating the Terminal Menus 32
Terminal Menu Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Window Panes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Window Pane Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Right Window Pane Notation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Additional Terminal Menu Window Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Navigating Using the Keyboard Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Moving through the Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Session Management Keystrokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Keystrokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
32
32
32
33
33
33
34
34
35
35
FIGURES
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Figure 11.
Figure 12.
Figure 13.
Figure 14.
Figure 15.
Figure 16.
12
12
16
17
17
18
20
20
24
25
26
27
28
30
31
32
1.
The Express 6503 is a serial (DCE) to SHDSL data service unit (DSU) designed for small offices and branch offices
to provide cost-effective access to high-speed SHDSL services. The Express 6503 preserves the customer's investment in existing business class routers, allowing them to take advantage of New World applications and Packet Telephony. It offers an economical migration path utilizing ATM and Frame Relay over SHDSL without requiring
replacement of existing networking equipment.
The Express 6503 provides small offices and branch offices with fast, affordable, and easy-to-use access to the Internet and corporate network. The Express 6503 makes DSL services and applications accessible to the office router or
to the desktop. It supports an integrated SHDSL WAN interface and a serial interface to the router and can operate at
symmetric speeds of up to 2312 kbps.
On the Express 6503, the terminal menu is the access point to all other operations. Each terminal menu item has several
functions and submenus that identify and provide access to specific operations and parameters. These menu selections
are described later in this User Interface Guide (pages 18 and following).
See Appendix A. Navigating the Terminal Menus on page 32 for instructions about navigating the
terminal menus.
SHDSL WAN Support (ITU-T G.991.2) - The Express 6503 supports serial full duplex bidirectional data transport of up to 2312 kbps.
Synchronous Serial Interface - The serial interface can support either V.35 or X.21 protocols.
FRF.8 Frame Relay to ATM Interworking Support - The Express 6503 supports FRF.8 Frame/ATM service interworking. It maps Frame data-link connection identifiers (DLCIs) to ATM permanent virtual circuits (PVCs); up
to four VCs can be configured in the Express 6503.
FRF.5 Frame Relay to ATM Interworking Support - DLCIs can be assigned automatically or provisioned.
Priority Queues - The Express 6503 supports high and low priority traffic queues for prioritizing traffic across
the WAN link.
Management Support - The Express 6503 is managed through a command-line interface accessible locally
through the management serial port or remotely through Layer 3 in-band management features.
Safety and Compliance - The Express 6503 is designed for worldwide safety and electromagnetic certifications
(EMC).
Front Panel
Figure 1 shows the Express 6503 front panel, which contains eight LEDs. Table 1 describes these LEDs.
COLOR
DESCRIPTION
PWR
Green
Power Indication
NET
Green
ALM
Red
TEST
Amber
TD
Green
RD
Green
RS
Green
Request to Send
CS
Green
Clear to Send
Rear Panel
The Express 6503 rear panel (Figure 2) contains the following connectors:
NETWORK
X.21
V.35
CRAFT
90-240/VAC 50/60Hz .1A
SHDSL interface
serial interface
serial interface
management/control
power input
V.35
NETWORK
X.21
CRAFT
Connector Pinouts
Table 2 below and Table 3 on page 14 give the pinouts for the V.35 and X.21 connectors.
Table 2. X.21 Interface
Pin
Name
I/O
Description
Shield
I/O
TD-A
Transmitted Data
RTS-A
Request to Send
RD-A
Received Data
CD-A
Carrier Detect
CLK-A
Signal Timing
ETC-A
SG
I/O
Signal Ground
TD-B
10
RTS-B
11
RD-B
12
CD-B
13
CLK-B
14
ETC-B
15
NC
N/A
No Connection
Name
I/O
Description
Shield
I/O
SG
I/O
Signal Ground
RTS
Request To Send
CTS
Clear To Send
DSR
CD
Carrier Detect
DTR
J*
RI
Ring Indicator
SD-A
Send Data
RD-A
Receive Data
SD-B
RD-B
TC-A
RC-A
Receive Clock
TC-B
RC-B
ST-A
Send Timing
AA
ST-B
K,L
NC
N/A
No Connection
M,N
NC
N/A
No Connection
BB
NC
N/A
No Connection
CC
NC
N/A
No Connection
DD
NC
N/A
No Connection
EE
NC
N/A
No Connection
FF
NC
N/A
No Connection
HH
NC
N/A
No Connection
JJ
NC
N/A
No Connection
KK
NC
N/A
No Connection
LL
NC
N/A
No Connection
MM
NC
N/A
No Connection
NN
NC
N/A
No Connection
2.
SPECIFICATIONS
Hardware
Table 4. Express 6503 Specifications
Characteristic
Description
SHDSL Interface
ATM PVCs
Up to 4 VPI/VCI mappings
User Interface
Protocols/Standards Supported
Data Rate
Flash memory
8 Megabits
DRAM
64 Megabits
Power Source
G.handshake
Description
AC input voltage
110-240 VAC
AC input current
~.1 Amps
Operating Temperature
Range
Operating humidity
Power Requirements
Regulatory Approvals
and Compliance
Standards Compliance
ATM Forum
Management
3.
SHDSL APPLICATIONS
Figure 3 below, Figure 4 on page 17, and Figure 5 on page 17 show some typical applications for the Express 6503.
LAN
FR Router
V.35/X.21
Serial Interface
Express 6503
PWR NET ALM TEST
TD RD RS CS
4
Express 6503
ATM
G.shdsl
SCU
18
DS3MX
1 0 1 5 L 1
1 8102
L 1
HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux QFC-C
QFC-C QFC-C QFC-C
DS3MX
1181200L1
1 8 10 20L1
POWER
FSE
ALM
ACO
LOCKOUT
LOCKOUT
ONLINE
ONLINE
APS
APS
F
TEST/
ENABLE
1181200L1
POWER
DSX
1181300L1
1181300L1
1181300L1
LBK
1
DSX
#1
DSX
#2
DSX
#2
DSX
#2
DSX
#2
DSX
#3
DSX
#3
DSX
#3
DSX
#3
DSX
#4
DSX
#4
DSX
#4
DSX
#4
10
10
10
DSL
PWR
#1
PWR
DSX
#1
#1
TS
TS
ALM
ALM
ACT
P
G R N=NORM
Y EL = MAN
ACT
P
GRN
YEL
= NOR
M
=M A N
G R N=NORM
YEL=MA
R
X
ACT
ACT
M
O
N
ACT
1 81 0
HTU-C
1 81 01L
HTU-C
18
1 1 81
1 1 8 1 01L
PWR
DSX
TS
TS
LP1
LP2
LP1
LP2
ALM
TX
EQ
RX
HTU-C
1 81 01L
DSX
LP1
LP2
ALM
TX
HTU-C
PWR
TS
LP1
LP2
ALM
EQ
RX
0 1 L 1
DSX
TS
LP1
LP2
TX
HTU-C
PWR
DSX
TS
LP1
EQ
RX
1 1 0 1 L1
PWR
DSX
TS
ALM
TX
EQ
RX
HTU-C
1 1 8 1 1 0 1L
PWR
DSX
LP2
ALM
TX
EQ
RX
HTU-C
1 1 81 01L
PWR
LP1
LP2
ALM
TX
EQ
RX
TS
LP1
LP2
ALM
TX
DSX
TS
LP1
LP2
EQ
RX
HTU-C
PWR
DSX
TS
LP1
ALM
TX
1 1 8 1 1 0 1 L 1
PWR
DSX
TS
LP1
LP2
ALM
EQ
RX
HTU-C
1 1 81 01L
PWR
DSX
TS
LP2
TX
1 L 1
PWR
DSX
LP1
EQ
RX
TX
MO
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
LP2
ALM
TX
EQ
RX
RX
TX
MO
N
ALM
TX
EQ
RX
RX
TX
MO
N
TX
EQ
RX
RX
TX
MO
N
EQ
RX
RX
TX
MO
N
RX
MO
N
RX
RX
ACT
ACT
ACT
G R N=NORM
YEL=MAN
GRN=NORM
P
GRN = NORM
YEL = MAN
TX
MO
RX
P
GRN = NORM
YEL = MAN
TX
RX
A
HTU-C
1 8 1 1 0 1L
PWR
TS
ALM
TX
EQ
TX
M
O
N
RX
A
GRN = NORM
YEL = MAN
HTU-C
1 81 1 01L
DSX
LP2
ALM
TX
RX
HTU-C
PWR
LP1
LP2
TS
LP1
6V
TX
M
O
N
RX
1 01L
DSX
TS
ALM
6V
TX
M
O
N
ACT
T
X
1 18
PWR
DSX
LBK
LP
ALM
6V
TX
RX
P
G RN = NORM
Y EL = M A N
HTU-C
1 81 01L
PWR
DSX
LBK
LP
ALM
6V
TS
ALM
ACT
HTU-C
1181310L1
PWR
DSX
LBK
LP
ALM
PWR
DSX
TS
ALM
DSL
1181310L1
PWR
DSX
LBK
LP
ALM
PWR
DSX
T1-OR T1-OR
1181310L1
PWR
DSX
LBK
1
DSL
1181310L1
PWR
DSX
LBK
1
DSL
T1-OR T1-OR
1181300L1
POWER
DSX
LBK
1
10
TEST/
ENABLE
1181200L1
POWER
DSX
STA US
TEST
SEL CT
1181200L1
POWER
POWER
STA US
TEST
MODE
HST
ACO
GRN = NORM
YEL = MAN
ACT
GRN=NORM
YE L = M AN
YEL=
M AN
ACT
ACT
ACT
G R N =N O R M
YEL=MAN
G R N =N O R M
YEL=MAN
GRN
ACT
YEL=
=N O R M
M AN
ACT
GRN=NORM
Y EL=M
ACT
GRN=NORM
A N
YE L=M
ACT
GRN=NORM
A N
Y EL=M
ACT
G R N=NORM
Y EL=M
A N
ACT
GRN=NORM
A N
Y E L = MA
ACT
GRN=NO
R M
Y E L=MA
ACT
G RN=
N ORM
GR N= N ORM
Y E L=MA
N
YEL=MAN
ATM
Network
SCU
DS3MX
1 810 5L1
1 1 81 02 L1
DS3MX
1 8 102
0 L1
POWER
HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux QFC-C
QFC-C QFC-C QFC-C
1181200L1
FSE
ALM
ACO
LOCKOUT
LOCKOUT
ONLINE
ONLINE
APS
APS
F
TEST/
ENABLE
DSL
1181200L1
POWER
DSX
LBK
LBK
10
10
DSL
1181300L1
1181300L1
T1-OR T1-OR
1181310L1
1181300L1
10
PWR
#1
DSX
#1
DSX
#1
DSX
#2
DSX
#2
DSX
#2
#3
#3
#4
DSX
#3
DSX
#4
DSX
#3
DSX
#4
TS
TS
TS
TS
ALM
ALM
ALM
ALM
ACT
DSL
ACT
P
GRN=N
O R M
YE L =MAN
ACT
P
G RN
YE
= N OR M
L = MAN
HTU-C
18
1181310L1
PWR
DSX
N =NORM
YEL=MAN
GR
N = N OR M
Y EL = MAN
R
X
ACT
M
O
N
RX
A
ACT
P
GRN = NORM
YEL = MAN
1 1 81
HTU-C
1 81 01
HTU-C
1 1 8 10
1 8 1 01L
HTU-C
1 18
HTU-C
1 81 0
HTU-C
1 81 01
HTU-C
TS
LP1
LP1
LP2
LP2
ALM
TX
ALM
TX
EQ
1 10 1L
DSX
TS
LP1
LP2
EQ
18
PWR
DSX
TS
ALM
TX
RX
HTU-C
1 1 8 1 1 0 1L
PWR
DSX
LP1
LP2
EQ
RX
L 1
PWR
TS
ALM
TX
EQ
RX
1 L 1
DSX
LP2
ALM
TX
EQ
HTU-C
PWR
LP1
LP2
ALM
TX
RX
1 L 1
TS
LP1
LP2
EQ
DSX
TS
LP1
ALM
TX
RX
1 8 10
PWR
DSX
TS
LP1
LP2
HTU-C
1 18 10 L1
PWR
DSX
TS
EQ
RX
1 01L
PWR
DSX
ALM
TX
EQ
RX
PWR
LP1
LP2
ALM
TX
EQ
RX
HTU-C
1 1 8 1 1 01L
TS
LP1
LP2
ALM
TX
EQ
DSX
TS
LP1
LP2
ALM
TX
HTU-C
PWR
DSX
TS
LP1
LP2
RX
1 L1
PWR
DSX
TS
EQ
RX
L 1
PWR
DSX
ALM
TX
EQ
01L
PWR
LP2
ALM
TX
TX
ACT
TX
MO
N
RX
A
P
GRN = NORM
YEL = MAN
HTU-C
L 1
LP1
LP2
6V
RX
RX
TX
TX
TX
EQ
EQ
RX
TX
M
O
N
RX
1 1 81 10
TS
LP1
ALM
6V
TX
M
O
N
RX
ACT
T
X
DSX
TS
ALM
TX
HTU-C
PWR
DSX
LBK
LP
ALM
6V
RX
TX
M
O
N
P
GR
1 10 L1
PWR
DSX
LBK
6V
DSX
DSX
LP
ALM
PWR
DSX
#2
#4
PWR
DSX
LBK
LP
ALM
PWR
#1
DSX
DSX
1181310L1
PWR
DSX
LBK
LP
PWR
DSX
DSX
T1-OR T1-OR
1181310L1
PWR
DSX
LBK
1
DSL
1181300L1
POWER
DSX
LBK
1
10
TEST/
ENABLE
1181200L1
POWER
DSX
STA US
TEST
SEL CT
1181200L1
POWER
POWER
STA US
TEST
MODE
HST
ACO
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
TX
MO
N
RX
MO
N
RX
MO
N
RX
TX
MO
N
RX
MO
N
RX
RX
ACT
ACT
ACT
ACT
GRN=NORM
GRN=NORM
GR N=NORM
YE L =MAN
P
GRN = NORM
YEL = MAN
TX
MO
GRN = NORM
YEL = MAN
YEL=M
AN
YEL=MAN
ACT
ACT
GRN=NO
R M
Y EL=MAN
ACT
GRN=NORM
YEL
=MAN
ACT
GRN=NORM
YEL=MAN
ACT
GRN=NORM
YEL=MA
ACT
GRN=NORM
YEL=MAN
GRN=NORM
YEL=MAN
ACT
ACT
G R N=NORM
YEL=MAN
GRN=NORM
ACT
YEL=M
AN
ACT
GRN=NORM
YEL=M
AN
ACT
GRN=NORM
YEL=MAN
GRN=NORM
YEL=MAN
ATM
G.shdsl
LAN
FR Router
V.35/X.21
Serial Interface
Express 6503
PWR NET ALM TEST
TD RD RS CS
4
Express 6503
LAN
ATM Router
ATM
Network
SCU
DS3MX
1 1 8 1 0 1 5 L 1
1 1 8 1 0 2 0 L 1
P O W ER
DS3MX
1 1 8 1 0 2 0 L 1
HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux QFC-C
QFC-C QFC-C QFC-C
P O W ER
S TA TU S
S TA TU S
TES T
TES T
LO C K O U T
LO C K O U T
O N L IN E
O N L IN E
1181200L1
P O W ER
D S X
LB K
1
M O D E
S ELEC T
H S T
FS E
A C O
A LM
A C O
C
A P S
A P S
F
T
TES T/
TES T/
EN A B LE
EN A B LE
7
8
9
1181200L1
P O W ER
D S X
LB K
1
2
3
4
5
6
7
8
9
1181200L1
P O W ER
D S X
LB K
1
2
3
4
5
6
7
8
9
1181200L1
1181300L1
1181300L1
1181300L1
T1-OR T1-OR
1181310L1
1181300L1
P O W ER
3
4
P W R
#1
D S X
D S X
#3
D S X
#4
7
8
9
10
D S X
#2
D S X
TS T
A C T
D S X
A C T
D S X
#3
#4
A C T
P
G R N = N O R M
YEL = M A N
D S X
#2
D S X
D S X
D S X
TS T
#2
#3
#4
A C T
1181310L1
1181310L1
P W R
G R N = N O R M
YEL = M A N
R
X
6V
R
X
6V
A
P
GRN = NORM
YEL = MAN
R
X
6V
1 1 8 1 1 0 1 L 1
HTU-C
1 1 8 1 1 0 1 L 1
P W R
D S X
1 1 8 1 1 0 1 L 1
1 1 8 1 1 0 1 L 1
TX
TX
R X
R X
EQ
1 1 8 1 1 0 1 L 1
1 1 8 1 1 0 1 L 1
P W R
1 1 8 1 1 0 1 L 1
1 1 8 1 1 0 1 L 1
1 1 8 1 1 0 1 L 1
1 1 8 1 1 0 1 L 1
D S X
TS T
LP 1
TS T
LP 1
LP 2
LP 1
LP 2
A LM
HTU-C
P W R
D S X
TS T
LP 1
LP 2
A LM
HTU-C
P W R
D S X
TS T
LP 1
LP 2
A LM
HTU-C
P W R
D S X
TS T
LP 1
LP 2
A LM
HTU-C
P W R
D S X
TS T
LP 2
LP 2
A LM
A LM
TX
TX
TX
TX
TX
TX
TX
R X
R X
R X
R X
R X
R X
R X
EQ
R X
HTU-C
1 1 8 1 1 0 1 L 1
D S X
LP 1
EQ
HTU-C
P W R
TS T
A LM
TX
EQ
HTU-C
D S X
LP 1
LP 2
A LM
TX
R X
EQ
P W R
TS T
LP 1
LP 2
A LM
TX
R X
EQ
1 1 8 1 1 0 1 L 1
D S X
TS T
LP 1
LP 2
A LM
TX
R X
EQ
HTU-C
P W R
D S X
TS T
LP 1
LP 2
A LM
HTU-C
P W R
D S X
TS T
LP 1
LP 2
A LM
HTU-C
P W R
D S X
TS T
LP 1
LP 2
A LM
TX
R X
EQ
M
O
N
TX
TX
MO
R X
A C T
P
GRN = NORM
YEL = MAN
HTU-C
P W R
TS T
LP 2
1 1 8 1 1 0 1 L 1
D S X
LP 1
HTU-C
P W R
TS T
T
X
EQ
EQ
EQ
EQ
EQ
EQ
TX
M
O
N
R X
A C T
A LM
+
T
X
TX
M
O
N
R X
A C T
1 1 8 1 1 0 1 L 1
D S X
LB K
LP
A LM
+
T
X
TX
M
O
N
R X
HTU-C
P W R
D S X
LP
A LM
+
T
X
TX
A LM
A
P
G R N = N O R M
YEL = M A N
T1-OR T1-OR
D S X
LB K
LP
#1
D S X
D S X
TS T
A LM
A
A LM
P W R
#1
6V
#2
#3
#4
A LM
A
P
G R N = N O R M
YEL = M A N
P W R
#1
D S X
D S X
TS T
A LM
P W R
D S X
A LM
P W R
D S X
D S L
LB K
LP
10
D S L
P W R
D S X
LB K
10
D S L
1181310L1
P W R
D S X
LB K
10
D S L
TX
MO
TX
MO
TX
MO
TX
MO
TX
MO
TX
MO
TX
MO
TX
MO
TX
MO
TX
TX
R X
R X
R X
R X
R X
R X
R X
R X
R X
R X
R X
R X
R X
MO
MO
MO
A C T
A C T
A C T
A C T
A C T
A C T
A C T
A C T
A C T
A C T
A C T
A C T
A C T
A C T
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
G R N =N O R M
YEL=M A N
P
GRN = NORM
YEL = MAN
TX
MO
R X
A C T
GRN = NORM
YEL = MAN
ATM
G.shdsl
Express 6503
PWR NET ALM TEST
TD RD RS CS
4
Express 6503
V.35/X.21
Serial Interface
FR Router
LAN
Express 6503
Express 6503
DCE Traffic
V.35/X.21
Serial Interface
G.shdsl
PWR NET ALM TEST
TD RD RS CS
TD RD RS CS
4
Express 6503
LTU
4
Express 6503
NTU
V.35/X.21
Serial Interface
DCE Traffic
4.
System Info
The SYSTEM INFO menu provides basic information about the unit and contains data fields for editing information.
Figure 6 displays the items available when you select this menu item.
>System Name
Provides a user-configurable text string for the name of the Express 6503. This name can help you distinguish between
different installations. You can enter up to 40 alpha-numeric characters in this field, including spaces and special characters (such as an underbar). This name will appear on the top line of all screens.
>System Location
Provides a user-configurable text string for the location of the Express 6503. This field is to help you keep track of the
actual physical location of the unit. You can enter up to 40 alphanumeric characters in this field, including spaces and
special characters (such as an underbar).
>System Contact
Provides a user-configurable text string for a contact name. You can use this field to enter the name, phone number,
or email address of a person responsible for the Express 6503. You can enter up to 40 alpha-numeric characters in this
field, including spaces and special characters (such as an underbar).
>Unit Name
Product-specific name for the Express 6503.
>CLEI Code
CLEI code for the Express 6503.
>Serial Number
Serial number of the Express 6503.
>Firmware Revision
Displays the current firmware revision level of the Express 6503.
>Bootcode Revision
Displays the bootcode revision.
>System Uptime
Displays the length of time since the Express 6503 reboot.
Each time you reset the system, this value resets to 0 days, 0 hours, 0 min, and 0 secs.
>Date/Time
Displays the current date and time, including seconds. This field can be edited. Enter the time in 24-hour format (such
as 23:00:00 for 11:00 pm). Enter the date in mm-dd-yyyy format (for example, 10-30-2001).
System Config
Set up the Express 6503 operational configuration from the SYSTEM CONFIG menu. Figure 7 shows the items included
in this menu.
>Protocol Config
Use this menu (Figure 8) to access ATM menus.
ATM/FR IWF
This menu contains the setup and status for the ATM/Frame Relay interworking functions.
Mode
The MODE setting configures the V.35 port for FRF5 or FRF8 operation, depending upon the application being supported.
FRF5
This is also known as Network Interworking. Use this mode for Frame Relay over ATM.
FRF8
This is also known as Service Interworking. In this mode, the Express 6503 performs a translation
between Frame Relay and ATM protocols.
Configuration
The CONFIGURATION menu is used to support the configuration of Frame-to-ATM interworking, signaling formats, timeout values, and PVC settings.
NAME
ATM VPI
ATM VCI
PCR
QOS
DE MAP
CLPI MAP
D/C
HEADER
MAINT PROTOCOL
MUX MODE
DLCI MAP
FR DLCI
ATM VPI
ATM VCI
PCR
QOS
TRANSLATE
DE MAP
FECN MAP
Status
Frame Relay
PORTS
PORT INDEX
Port number.
SIGNAL STATE
TX FRAMES
RX FRAMES
TX BYTES
RX BYTES
PVCs
PORT
Port number.
DLCI
DLCI number.
STATE
TX FRAMES
RX FRAMES
TX BYTES
RX BYTES
ATM Config
Use the ATM CONFIG menu (Figure 9) to set the parameters listed below.
The IDLE CELLS format must be configured for either ATM FORUM or ITU. Configuring this setting
incorrectly for a particular circuit will cause poor performance at the ATM layer.
This setting must match the configuration setting of the ATM switch or DSLAM at the other end of
the circuit.
Data Scrambling
DATA SCRAMBLING can be ENABLED or DISABLED for cell traffic. Configuring this setting incorrectly
for a particular circuit will cause poor performance at the ATM layer.
This setting must match the configuration setting of the ATM switch or DSLAM at the other end of
the circuit.
ATM Stats
Use the ATM STATS menu (Figure 10) to set the parameters listed below.
This is the number of cells received and discarded for an unconfigured PVC.
AP: Receive Cell Errors
Action
Baud Rate
This is the asynchronous rate that the maintenance port will run. The possible values are 300, 1200, 2400,
4800, 9600 (def), 19200, 38400, 57600, and 115200.
Data Bits
This is the asynchronous bit rate that the maintenance port will run. The possible values are 7 or 8 (def) bits.
Parity
This is the asynchronous parity that the maintenance port will run. The possible values are NONE (def), ODD,
or EVEN.
Stop Bits
This is the stop bit used for the maintenance port. The possible values are 1 (def), 1.5 or 2.
>DTE Select/Config
Figure 12 shows this menu.
>SHDSL Config/Stats
Figure 13 below shows this menu.
System Utility
Use the SYSTEM UTILITY menu (Figure 14) to upgrade firmware.
>Upgrade Firmware
Updates firmware when Express 6503 enhancements are released.
Transfer Method
Use XMODEM to load the upgrade code through the CRAFT port using any PC terminal emulator with
xmodem capability. (See Appendix B. Updating Express 6503 Firmware using XMODEM on page 36 for
more information.)
Filename
Enter filename to download.
Start Transfer
This activator is used when the configurable items in this menu are complete.
System Test
Use the SYSTEM TEST menu (Figure 15) to test and debug typical applications.
>DTE Loopback
All data is looped back to the serial interface.
>Network Loopback
All data is looped back to the network interface.
Right Pane
Left Pane
Status Bar
Mode
Navigation Help
System Tim e
Menu Path
The first line of the terminal menu window (the menu path) shows the sessions current position (path) in the menu
structure. For example, Figure 16 shows the top-level menu with the cursor on the SYSTEM INFO submenu; therefore,
the menu path reads EXPRESS 6503 SYSTEM INFO.
Window Panes
When you first start a terminal menu session, the terminal menu window is divided into left and right panes. The left
pane shows the list of available submenus, while the right pane shows the contents of the currently selected submenu.
Window Pane Navigation
Use the following chart to assist you in moving between and within the two window panes.
To move...
Tab
Enter
Right arrow
Tab
Escape
Left arrow
Up arrow
Down arrow
Left arrow
Right arrow
Means that...
[+]
[DATA]
<+>
Underlined field
Navigation Help
Lists characters used for navigating the terminal menu (CtrlZ). See also Moving through the Menus on page 34.
System Time
Press J while the cursor is located on a menu item, and you jump back to the
main screen.
Go to another menu item, press J, and you jump back to the screen that was
displayed the first time you pressed J.
Press J when you want to jump between these items.
Select items.
Arrows
Enter
Cancel an edit.
Escape
Escape
Tab or
Arrows
Backspace
Press this...
Ctrl-L
Ctrl-S
Ctrl-R
To save time, only the portion of the screen that has changed is refreshed.
This option should be necessary only if the display picks up incorrect
characters.
Configuration Keystrokes
To do this...
This setting restores the factory defaults based on the location of the cursor. If the
cursor is on a module line (in the MODULES menu), then only the selected module is
updated to factory defaults.
C
If the cursor is over the index number of a list, then all of the items in the row of the
list are copied.
P
>
Decrement the value of certain types of fields by one when you paste information into
those fields.
<
For example, add a new item to the DLCI MAPPING by pressing I while the cursor is
over an index number.
D
Getting Help
The bottom line of the terminal menu window contains context-sensitive help information. When the cursor is positioned over a set of configuration items, a help message displays (when available) providing a description of the item.
When more detailed help is available for a particular item, ^A displays at the bottom of the window. At this point, if
you press Ctrl-A, a pop-up help screen displays with information about the item.
Press Ctrl-Z to activate the help screen that displays the available keystrokes you can use to navigate the terminal
menus.
Make certain that the communications software package being used has flow control turned off.
Before beginning this procedure, you must obtain the appropriate update file from ADTRAN Technical Support at
(888) 4ADTRAN (423-8726).
An XMODEM download can be initiated by pressing B and cycling power to the unit or by using the console menus.
The following materials are required.
To prevent electrical shock, do not install equipment in a wet location or during a lightning
storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules, wear
an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in
antistatic packing material when transporting or storing. When working on modules, always place
them on an approved antistatic mat that is electrically grounded.
Updating Firmware
Perform the Steps Below in the Order Listed
1.
2.
To shorten transmit time, select the option from the menu to change the transmit rate to 115.2 baud
or the highest rate supported by the terminal emulation software. If this transmit rate is changed,
change emulation software properties to match this rate and disconnect and connect again. Press
Enter until the menu appears.
3.
Choose option 1, BEGIN XMODEM DOWNLOAD NOW, from the menu to start the XMODEM file
download.
4.
Press Y at the START FLASH DOWNLOAD NOW prompt to continue with the XMODEM file transfer.
When Express 6503 is ready to receive the XMODEM upload, the menu screen will display
Transmit Flash . . . download file now. If this does not appear, please review the steps above for
possible configuration errors.
5.
From the terminal emulation software, begin the XMODEM upload by using the appropriate
command sequence. (If necessary, refer to terminal emulation software documentation for
help. Also, when specifying the filename, ensure that the file transferred is the one provided by ADTRAN. Otherwise, the update will not complete successfully.)
Because XMODEM data is being transferred in-band through the menu interface, the VT 100
menus of Express 6503 will be inoperable from the CRAFT port.
6.
When the update has successfully completed, TRANSFER COMPLETE appears in the terminal
window. If an error occurs during the update, an error message will display in the terminal
window. If this occurs, return to Step 3 and attempt the update again. If the same error
occurs, contact ADTRAN Technical Support.
7.
After the TRANSFER COMPLETE message has been displayed, cycle the power to the Express
6503.
8.
Change the emulation software properties to 9600 baud. Disconnect and connect to the
unit at this transmit rate and continue configuring the unit as normal.
It is suggested that a factory default be conducted after the unit is updated with new firmware.
2.
3.
4.
5.
When Express 6503 is ready to receive the XMODEM upload, the menu screen will clear and
display Transmit Flash . . . download file now. If this does not appear, please review the steps
above for possible configuration errors.
6.
From the terminal emulation software, begin the XMODEM upload by using the appropriate
command sequence. (If necessary, refer to terminal emulation software documentation for
help. Also, when specifying the filename, ensure that the file transferred is the one provided by ADTRAN. Otherwise, the update will not complete successfully.)
Because XMODEM data is being transferred in-band through the menu interface, the VT 100
menus of Express 6503 will be inoperable from the CRAFT port.
7.
When the update has successfully completed, TRANSFER COMPLETE displays in TRANSFER
STATUS. The module restarts immediately and resumes operation. If an error occurs during
the update, an error message will display in the TRANSFER STATUS field. If this occurs, return
to Step 3 and attempt the update again. If the same error occurs, contact ADTRAN Technical Support.