R134aREFRIGERATIONTECHNICIAN

HANDBOOK

Version2.1
Updated:May10,2012

USACO

TABLEOFCONTENTS
1.0

OVERVIEW...................................................................................................................................................4
BACKGROUND............................................................................................................................................4

2.0

HANDBOOKINTRODUCTION.......................................................................................................................5
SAFETYANDENVIRONMENTALNOTES......................................................................................................5
RECEIVINGREFRIGERATEDCONTAINERSONDANGERLIST....................................................................6
HANDLINGPROCEDURESFORALLR134AREFRIGERATEDUNITS..............................................................7

3.0

IDENTIFYINGFAKE/COUNTERFEITR134AREFRIGERATEDGAS.................................................................8

4.0

R134AREFRIGERATEDCYLINDERTESTINGUNITANDPROCEDURES.........................................................9
HALIDETORCHANDVENTILATIONHOODASSEMBLY...............................................................................9
CONGLOBALGASEXTRACITONANDANALYSISRECOVERYSYSTEM(CGEARS)......................................11
PROCEDURESFOREXTRACTINGANDTESTINGR134AREFRIGERATEDGASCYLINDERS.........................12
LABELLINGANDTRACKINGTESTRESULTS...............................................................................................14

5.0

NEWSAFETYREQUIREMENTSFORSERVICINGR134AREFRIGERATEDCONTAINERS..............................16
ADDITIONALSAFEGUARDSIMPLEMENTEDATCONGLOBALINDUSTRIES...............................................17

6.0

CONGLOBALGASEXTRACTIONANDANALYSISRECOVERYSYSTEM(CGEARS).....................................19
SAMPLINGMETHODS...............................................................................................................................19
IMPORTANTPRECAUTIONS......................................................................................................................19
CGEARSMETHODTOCHECKREFRIGERATIONMACHINERYFORCHLORIDECONTAMINATION............20
PREPARATION.............................................................................................................................20
EQUIPMENT................................................................................................................................20
PREPARINGTHECGEARSDEVICE...............................................................................................22
TAKINGSAMPLESFROMREFRIGERATIONMACHINE..............................................................................23
SAMPLEPORTS............................................................................................................................23
SAMPLINGPROCESS....................................................................................................................23
FLAMETESTINGOFEXTRACTEDSAMPLES..................................................................................27
FLAMETESTRESULTS..................................................................................................................28
CLEANINGTHECGEARS..............................................................................................................29

7.0

EMPLOYEEACKNOWLEDGMENT...............................................................................................................30

ThisR134aRefrigerationTechnicianHandbookwasdevelopedasinstructionalguidelinesforrefrigeration
personnelofConGlobalanditsrelatedcompanies.Wehavemadethisinformationpublicsolelyasasourceof
informationtootherswhoareinterestedintheservicingofrefrigeratedcontainers.Wearemakingthis
documentavailableasinformationonlyandareNOTPROMOTINGORSUGGESTINGanyoneoutsideof
ConGlobalanditsrelatedcompaniesadoptanyofthemeasurescontainedinthisdocument.Anypersonnel
servicingrefrigeratedcontainersshoulddotheirowninvestigationandimplementsafetypoliciessuitedto
theirspecificsituationandconditions.
Thishandbookisintendedtobeanevolvingdocumentandwillchangeasnewinformationisdiscoveredand
madeavailabletotheindustry.Commentsandsuggestionsforimprovingtheeffectivenessoftheinformation
andprocedurescontainedhereinarewelcomedandencouraged.Commentsandsuggestionsshouldbe
directedtoPriscillaYataatpyata@cgini.com.
ConGlobalreservestherighttoamend,modifyandretractanyorallpartsofthiswritingasnewinformation
maydictate.

3|Page

Version2.1Updated:5/10/2012

USACO

1.0 OVERVIEW

BACKGROUND
TheRefrigeratedContainerindustryhasrecentlyexperiencedseveralinstanceswherebyrefrigerated
containershaveviolentlyandunexpectedlyexploded,resultinginmultipledeathsofservicetechnicians
aroundtheworld.Todate,investigationsindicatethattheexplosionswerecausedbytheintroductionof
counterfeitR134arefrigerantcontaining,amongothergases,significantamountsofR40(methylchloride).As
ofthiswriting,alloftheunitsthathaveexplodedreceivedarefrigerantgaschargeinVietnam.
However,anadditionalinvestigationofinstockrefrigerantgassuppliesatrepaircompaniesaroundthe
world,aswellasonboardmarinevessels,hasturnedupcounterfeitgascontainingR40.Further,inarecent
effortbymembersoftheContainerOwnersAssociation(COA)whoconductedasamplingandtestinganalysis
ofseveralhundredrefrigeratedunitsacrosssevenlocations,inthreedifferentcountries,involvingunitsfrom
twelvedifferentSSLines(orLeasingCompanies),revealedthatsomeunitswhichwerenotservicedinVietnam
werefoundandconfirmedtohavecounterfeit/contaminatedrefrigerantcontainingseveraldifferent
chlorinatedgasses,includingR40.Andasexpected,manyoftheunitsthatreceivedgasserviceinVietnam
werealsofoundtobecontaminated.Thissupportsthegrowingsuspicionthatthiscounterfeit/contaminated
refrigerantissueisnotisolatedtounitshavingbeenservicedinVietnam,asoriginallythought.
Sincetheearlyannouncementsofthisproblemin2011,ConGlobalIndustrieshasbeeninvolvedwithan
internationalcommunityofexperts,bothinthecontinuedinvestigationaswellasthedevelopmentoftest
methodstoeffectivelyscreenunits.ConGlobal,alongwithotherindustryleaders,hasbeenadrivingforce
behindthedevelopmentofpoliciesandeducationalprogramsdesignedtosafeguardrefrigerationservice
personnelandtopreventtheproliferationandspreadofcounterfeit/contaminatedrefrigerant.Thisissueis
evolvingdaily,andwecontinuetolearnmorerelevantinformationwitheachcontaminatedcontainer
identified.
ConGlobalIndustries,Inc.andouraffiliatedservicecompaniesofUSACOinCostaRica,CoastalGreatSouthern
ontheU.S.EastCoast,andICAVEinMexico,areamongthelargestrefrigerationservicecompaniesinthe
world.Assuch,wehavetakenaveryseriousviewoftheissue.
AtConGlobalandallofouraffiliatedcompanies,thesafetyofourpersonnelaswellassafeguardingourclient
assetsareofparamountimportancetous.Accordingly,wedevelopedaseriesofprograms,disciplines,and
policiesbasedonthemostreliableandcurrentinformationavailable.
Withimmediateeffect,allConGlobalrefrigerationservicefacilitiesandservicetechniciansareadoptingthe
refrigerantgashandlingprotocoloutlinedinthishandbook,whichhasbeencarefullydesignedto:
1. Safeguardourcompanypersonnel
2. Safeguardourcustomerassets
3. Stoptheproliferationofcontaminatedgasinourindustry

4|Page

Version2.1Updated:5/10/2012

USACO

2.0 HANDBOOKINTRODUCTION
OnNovember11,2011,thecompanyissuedthefirstSAFETYBULLETINrelativetonewsthatisolated
refrigeratedunitsaroundtheworldhadexploded,causingcasualties,includingfatalities.
TheCompany(hereinmeanttoincludeConGlobalIndustries,CoastalGreatSouthern,ContainerCareIcave
Mexico,ContainerCareMexico,andUSACOCostaRica)issuedaseriesofpoliciesandprocedures,basedon
informationanddataknownatthattime,toprotectthesafetyandwellbeingofouremployeeswhohandle,
andperformmaintenance,repair,andinspectionofrefrigeratedcontainers.
Agreatdealofinformationandknowledgehasbeenaccumulatedsincethatdate.ThisRefrigeration
TechnicianHandbookistobeusedastheexclusivesetofpoliciesandproceduresforhandlingrefrigerated
containerunitswithinandbyallcompanypersonnelandsupersedesanypriorcommunication.
Eachandeveryrefrigerationtechnicianinthecompanymustbetrainedintheproceduresoutlinedinthis
manualbytheirsupervisor.Inaddition,everyrefrigerationservicetechnicianwillsigntheacknowledgment
pageattheendofthismanual,confirmingtheyhavereadthemanualinitsentirety;theyhavebeentrainedby
theirsupervisor;andtheyfullyunderstandandagreetoabidebyallthepoliciesandproceduresfoundwithin
thismanual.Inaddition,theGeneralManagerwillsigntheacknowledgementpage,verifyingtheemployee
hasbeentrainedandissatisfiedtheemployeehastherequiredinformationandskilltosafelyworkonall
refrigerationunits.
Therewillnodeviationfromthesepoliciesandprocedureswithouttheexplicitwrittenapprovalofeitherthe
PresidentorDirectorofSafetyandComplianceofthecompany.Thepoliciesandproceduresfoundwithinthis
manualapplytoALLR134aREFRIGERATIONUNITSservicedbyourcompany.
Anyrefrigerationtechnicianwhodoesnotfeelcompletelycomfortablecomplyingwiththepoliciesand
proceduresfoundinthismanualmustexpresstheirconcernswiththeirsupervisorpriortocommencingwork
onanyrefrigeratedunit.Anyrefrigerationtechnicianwhoobservesanythingoutoftheordinaryonany
refrigerationunitmustimmediatelystopandreporttheirconcernstotheirimmediatesupervisor.

SAFETYANDENVIRONMENTALNOTES
Abyproductofburninghydrocarbonchlorideisphosgenegas,whichisalethalgasincertainconcentrations.
ToensurethattheHalideFlametestcanbesafelyperformedusingtheventilationhooddescribedinthis
handbook;ConGlobalcontractedanenvironmentalhygienistfromAECOMtotesttheenvironmentatvarious
distancesaroundtheventhood,includingasamplingdevicelocatedonthetestingtechnician,andatthe
exhaustoutlet.AECOMusedOSHAMethod61asabasisforcompletingthesample.Thesampleperiodlasted
fivehoursand6burntestswereperformed,5ofwhichlastedapproximately30seconds,andthefinalburn
lastingapproximately1minute.BothR22andR134arefrigerantweretested.SinceR22containschloride,it
producesphosgenegaswhenburnedallowingAECOMtotesttheairqualityandrecordtheresults.

5|Page

Version2.1Updated:5/10/2012

USACO

TheAECOMtechniciantestedairflowrates,constructionofthehoodassembly,andsmoketestobservations.
TestmediahadtobeacquiredfromalabinNewYorkandwasshippedovernightunderrefrigerated
conditions.Thetestmedia,afterbeingexposedtothephosgenegas,wasreturnedtothelab,againunder
refrigeratedprotection.Thetestresultsreportedthelevelofphosgenegasat1/100oftheOSHAPermissible
ExposureLimitduringa4hourtimeframeandthusnotrepresentingasignificantrisktotechnicians
performingtheflametestwithasmokehoodinuse.

RECEIVINGREFRIGERATEDCONTAINERSONDANGERLIST
Tothebestofourability,theCompanyhasloadedclientsuppliedlistsofcontainersinTEC(Terminal
EquipmentControlSystem)thathavebeenservicedinVietnam.TheseunitsaredesignatedinTECasDanger
Units.Uponarrivalatoneofourdepots,refrigeratedcontainerswillbecheckedtoverifytheyarenot
identifiedinTECasaDANGERUNIT.
IfarefrigeratedunitarrivesatyourlocationandisdeterminedtobeonourDangerList,thecontainershould
beimmediatelymovedtoanisolatedareaofthedepot,andagassampletaken(followtheCGEARS
procedurecontainedherein).ThegassampleshouldbetestedusingaHalideFlameTesttodetermineif
chlorideispresentinthegas.IfaDangerUnittestspositiveforchloride,thecontainermustbemarkedwith
aLARGE,REDXatthebottomcornerofthecontainer,atthedoorend,andstacked/storedwiththeunits
facingeachotherortherefrigeratedunitblockedwithanothercontainer,preventingunauthorizedpersonnel
fromtamperingwiththem.Agastestplacardshouldimmediatelybeaffixedinaconspicuouslocationtothe
frontendofthecontainer.
ForDangerUnitsfailingtheHalideFlameTest,cuttheplugsoffoftheunits,closetotheplug.Puttheplug
insidethecordboxonthefrontoftheunitforanyDangerUnitthattestspositiveforchloride.
Themachineryshouldbestacked/storedcloseenoughtotheblockingcontainersuchthatapersoncannot
inadvertentlywalkbetweenthem.AllDangerUnitsstoredinthisfashionshouldbestoredatleast25feet
fromflammableorcombustiblematerials.
AsoutlinedintheCGEARSinstructions,asampleofanyunitfailingtheHalideFlametestshouldbesentto
McCampbellAnalyticalLaboratoryinPittsburgCAforGCMStesting.

McCampbellAnalytical,Inc.(MAI)
1534WillowPassRoad
Pittsburg,CA94565

(877) 252-9262
www.mccampbell.com

IfaDangerUnitpassestheHalideFlametest,itisconsideredsafeandcanbeservicedasdirectedbythe
client.

6|Page

Version2.1Updated:5/10/2012

USACO

HANDLINGPROCEDURESFORALLR134AREFRIGERATEDUNITS
Usethefollowingguidelinesonallrefrigeratedunits,includingthoseunitsontheDangerlistthatpassthe
HalideFlametest.
1. First,visuallyinspecttherefrigeratedcontrollertoconfirmtheunitisnotsetintheEmergencyRun
mode.
2. Iftheunithasasightglass,checkforanyindicationofabnormalappearance.
3. Whenstartingtheunit,nopersonnelshouldbeinfrontoftheunit,orbeinsidetherefrigerated
container.
4. Duringstartup,allpersonnelshouldbenocloserthan2containerunits(approx.15feet)from
refrigerationmachinery.
5. Beforeplugginginunit,ensuretherefrigerationunitcircuitbreakerandpowerswitchareintheon
orrun(closed)position.
6. Plugtherefrigeratedunitintoapowersourcethatisnotdirectlyinfrontoftherefrigeratedunitthat
hasthepowersourcebreakerturnedoff.
7. Turnonthebreakeratthepowersourceandwaitfortherefrigeratedunittogothroughitsstartup
procedure,untilthecompressorhasstartedandrunsfor35minutes.
8. Ifthecompressorexhibitssoundsofimproperoperation,suchasknocking,clanging,buzzing,orother
oddsounds,duringstartup,orifthecompressorbecomesunusuallyhot,turnoffthebreakeratthe
powersourceandperformtheCGEARSprocedure.AFTERALLOWINGTHECOMPRESSORTOCOOL
FORATLEAST30MINUTES.AfterpassingtheCGEARSprocedure,thentroubleshootasnormal.Ifthe
unitfailstheCGEARSprocedure,thensendthesampletoMcCampbellAnalyticallabandwaitfor
results.
9. Ifaunitfailstostart,disconnectitfrompowersource.
10. Theservicetechnicianshouldthenusethepowerpluginhandrulewhenworkingonunit.Thismeans
thetechnicianwillhavethepowercordplugwithhimpriortocommencinganyworkontheunit.
11. Forunitsthatdontstart,andonlyafterpowerisCONFIRMEDdisconnected,inspectalarmlogfor
failureindications.
12. Forunitsthatrequirepowertoviewalarms,disconnecttheoutputpowertothecompressorpriorto
connectingpower.
13. OnANYunitthatrequiresservice,wherebygaugesmustbeconnectedtotheunit,therefrigerant
mustfirstbetestedbyusingtheCGEARSextractionprocedure.IffreonpassestheHalideFlameTest,
workmaycommence.IftherefrigerantfailsHalideFlameTest,noworkshallbeperformeduntil
authorizationisgiven.
14. Ifanycompanytechnicianhasanydoubtorconcernaboutsafelyworkingonanyrefrigeratedunit,
theyshouldimmediatelyconsultwiththerefrigerationsupervisor.

7|Page

Version2.1Updated:5/10/2012

USACO

3.0 IDENTIFYINGFAKE/COUNTERFEITR134AREFRIGERATEDGAS
Thereareseveralthingstolookforwhentryingtoidentifyfake/counterfeitrefrigeratedgas.Outlinedbelow
aretwoexamplesofthingstolookfor.Ifyouspotoneofthesetanks,STOP,andtakeittoyourimmediate
supervisor.

Thetankontherightisacounterfeittank.SomecounterfeittanksspellDuPontasDupont(notethelower
casep).

Anotherwaytoidentifycounterfeitcylindersistheshapeofthehandlebase.Originalcylindershavestraight
handlebasesandcounterfeitcylindershavecurvedhandlebases.

8|Page

Version2.1Updated:5/10/2012

USACO

4.0 R134AREFRIGERATEDCYLINDERTESTINGUNITANDPROCEDURES
Thissectionoutlinestheassemblyofthehalideflameventilationhoodandthetestingproceduresfornew
R134arefrigeratedgascylindersatallConGlobalrefrigerationservicefacilities.Thepurposeoftestingnew
R134acylindersbeforeuseinservicingrefrigeratedcontainersistodetectwhethertheR134acylinderhas
beencontaminatedwithchlorinatedgasses,includingR40(MethylChloride).

HALIDETORCHANDVENTILATIONHOODASSEMBLY
Theunittotestrefrigeratedgasfromcylindersusesthefollowingcomponentsandmodifications:

CompactOversprayCollectorwithdimensionsof18HX22WX20D.Thispieceisreferredtoasa
venthood,purchasedfromMcMasterCARR(Partnumber9559T51).

Theventhoodismodifiedbythefollowingprocedures.

9|Page

Mountingtheunitontwolegsfabricatedoutofsheetmetal.

Drillingaholeinthebottomoftheventhoodsothehalideleakdetectorcanbeinserted
throughthebottom.

Paintingtheinterioroftheventhoodblacksotheflamecanbeeasilyseen.

Drillingaholeintheleftsideoftheventhoodsotheexplorationhosecanberoutedtothe
tankfortesting.

Installingaplexiglasscoveronthefrontusingapianohingetocontainfumesinhoodfor
ultimateventilation.(Note:Theopeningatthebottomoftheinstalledplexiglassisintentional
toallowforproperairflow.)

Outfittingtheexhaustfanmountedontherearoftheunitwithaluminumductingsothe
exhaustoutletisatasufficientdistance,asrequiredbylocalworkersafetyregulations.For
ConGlobalsNorthAmericanlocations,theexhaustshouldterminatesevenfeetabovethe
heightofthetechnicianshead.

Version2.1Updated:5/10/2012

USACO

Toensureconsistencyinassemblingthetestingunits,ConGlobalcentrallypurchasesventhoodsfrom
McMasterCARRanddropshipstoeachlocationthatneedsatestingunit.Wealsocentrallypurchasethe
plexiglassfrontcover,pianohinge,leakdetector,valves,fittingandgauges,andhoses.TheConGlobalLos
Angeleslocationfabricatesthesheetmetallegs,assemblesthevalveandconnector,andassemblesthehalide
torch.Theindividuallocationonlyneedstosecuretheexhaustductingwhichisavailableatmostlocal
hardwaresupplystores.
Fortheactualhalidetorchtestingapparatus,weareusingaNRPLeakDetectorthatmountsdirectlytoa
conventionalhandheldpropanebottle.Thepropanebottleismountedbetweentheventhoodstand,sothe
leakdetectorunitisinsidetheventhoodandthepropanebottleisbelowtheventhood(Seediagrams#1and
#1abelow).

Diagram#1

Diagram#1a

10|Page

Version2.1Updated:5/10/2012

USACO

CONGLOBALGASEXTRACITONANDANALYSISRECOVERYSYSTEM(CGEARS)
Thegaugeandconnectorassemblyconsistsofthefollowingcomponents:
A. Acme(auto)adaptortoflarefitting
B. flarefemaleunion
C. Quickconnectvalve
D. Regulator
E. Lowpressurerefrigerantgauge(R134a)
F. Lowlossline8inlengthwithballvalve,flarefittings
G. Femaleflareadaptortotubing
H. coppertubing
I.

adaptorfromtubingtocapillarytube

J.

Capillarytube(0.054innerdiameter)

K. Schraderadaptor(ThermoKingPart#669873)
L. Ballvalveflareconnections
M. Doublemaleflareconnector

Diagram#2

NoteThistestinggaugedeviceisrecommendedoveratypicalmanifoldgaugesetbecausethequantityof
gasisrestrictedbythedevicesize.Thiskeepsanydischarge,eitherintentionalorunintentional,toade
minimuslevel,asrequiredbyU.S.EPAregulationsection608.

11|Page

Version2.1Updated:5/10/2012

USACO

PROCEDURESFOREXTRACTINGANDTESTINGR134AREFRIGERATEDGASCYLINDERS
Ifpossible,priortodoingtheactualtestwithaR134acylinder,performthesametestonaR22sample,which
containschlorideandwillcreatethesameflamecolorchangetogreenasacylinderofR134athatis
contaminatedwithR40,R12,orR142b.Thisprocessisrecommendedsimplytoensurethatthetesting
technicianknowspreciselywhattolookforsincethechangeincolorcanberapid,andwilllastforonlya
secondortwo,dependingonthevolumeofrefrigerantpassingthroughthecapillarytube.Itisimperativethat
thetestingtechnicianshaveexperiencewithvisuallydetectingthechangeinflamecolorbeforeconductingthe
livetests.ThevideolinkbelowandthepicturesinDiagrams#3and#3aareexamplesoftheflamepriorto,
andafterexposuretogasseswithchloride.
Flametestingvideolink:www.youtu.be/JDBTxSJ7H8

Diagram#3ContaminatedR134aRefrigerantGas

Diagram#3aUncontaminatedR134aRefrigerantGas

Afteratestthatispositiveforchloride,andtoavoidapossiblefalsepositiveresult,beforethenextR134a
cylindertest,youneedtothoroughlycleanandpurgethetestinggaugeandconnectorwithcompressedairor
nitrogen.Ifthelinesarenotpurged,tracesofchloridemayremaininthetestinggaugecausingfalsepositive
readingswhentestingotherwisepureR134asamples.Asageneralrule,thetestinggaugeneedstobepurged
aftereachtestandparticularlyafterapositivechloridetestresultinginagreenflame.
Followtheseproceduresforflametesting.
1. ConnectapurgedandcleanedCGEARStoanitrogenbottleandpressuretestforleaks.
2. ConnectfittingAtoR134arefrigerantbottle,thenconnectSchraderadaptorL.Thenattachquick
connectvalveC.(Ifrefrigerantbottlehasfitting,connectSchraderadaptorL,andthenconnect
tobottlewithquickconnectvalveC.)
3. EnsureballvalvesMandGareclosed.
4. Connecttheexplorationtubefromthehalidetorchtothebarbedfittingontheinsideofthehood.
5. Connectanotherpieceofexplorationtubetotheoutsidebarbedfitting.

12|Page

Version2.1Updated:5/10/2012

USACO

6. Raisethecleardoorofthehoodandlightthetorchwithanignitionsource.
7. Adjustthecenterflameconesothatthetipoftheflameisjusttouchingthecopperreactorplate.

8. Afterthetorchisoperatingproperly,closetheplexiglassfrontcover.
9. Lettheflameburnuntilthereactorplateisglowingred(usually23minutes).
10. Slowlyopenthevalveoftherefrigerantbottleandthenopenquickconnectvalve,thenopenballvalve
Gandallowpressuretoreach6080psi.(Pressuremayvarydependingonambienttemperature.)
11. Closethevalveonthebottle,alsoclosethequickdisconnectvalveandballvalveGoftheCGEARS.
YouhavenowessentiallytrappedyourgastestsampleintheCGEARS.
12. DisconnecttheCGEARSfromtheR134acylinderandtaketestgaugetotheventilatedhalideflame
testlocation.
13. ConnectSchraderadaptorLtomaleconnectorNandthentocapillarytubeassembly.Insert
SchraderadaptorLintoquickdisconnectvalveC.
14. Insertthecapillarytubeintoasmallcontainerofwater,whilepositioningtheexplorationtubefrom
thehalidetorchapproximately1inchabovethewater.
15. OpenballvalveG,thenslowlyopenvalveCuntilaslightgasflowfromthecapillarytubeisvisually
confirmedbybubblesinthewater.Closelywatchthehalidetorchflamethroughtheslotsintheflame
shieldforabrief,temporarychangeinflamecolorfrombluetogreen.
16. Ifthereisacontaminantcontainingchloride,theflamewillturngreenwithinafewsecondsandburn
greenforbetween1and5seconds.Iftheflameremainsaconstantblue,thetankbeingtestedisfree
ofchloridecontaminants.

13|Page

Version2.1Updated:5/10/2012

USACO

LABELLINGANDTRACKINGTESTRESULTS
Anauditableprocessfortestinggassamplesisessentialtodocumentwhichcylindershavebeentestedto
preventadditionalcontaminatedgasfrombeingintroducedtorefrigeratedcontainermachines.Whenanew
gascylinderisreadytobeusedforservice,ahalidetestshouldbeperformedtodetermineifthegashasbeen
contaminated.Oncethecylinderhasbeentested,thetestingtechnicianwilluseanindeliblemarkertomark
DIRECTLYONTHECYLINDER1)thedepotlocation,2)cylindernumber,3)testdate,4)testresultand5)
techniciansignature.Thisinformationisthenrecordedonalogtocreateanaudittrailthatcanbeeasily
sharedwithcontainerownersandauditorsuponrequest.Anexampleofthelogisattachedasreference.
Currently,gascylindersdonothaveuniqueserialnumbersthatcanbeusedforidentification.Therefore,
repairfacilitiesneedtocreateauniquenumberforeachcylinderthatistested.AtConGlobalIndustries,the
cylindernumberwilladheretothefollowingformat.Itstartswithathreealphacoderepresentingthedepot
companyname;followedbyathreealphacoderepresentingthetestinglocation;andendswithasequential
threenumbercode.UsingCGISEA001asanexample,CGI=ConGlobalIndustries;SEA=Seattle,Washington;
and001=sequentialnumber.Ifacylinderisnotlabelledwithall5piecesoftestinginformationlistedabove,it
shouldnotbeused.
Afteratankisempty,thevalveshouldbeknockedoff.Besurethetankisemptyandproperlyevacuated
beforeknockingoffvalve!Thetankcanthenbescrapped.Crushingthetankmayberequiredbysome
recyclers.Checkwithyourlocalscrapmetalrecyclerfortheirspecificrequirement.Afterdestruction,notethe
destructiondateontheGasBottleTestingLogSheetunderthecommentssection.

14|Page

Version2.1Updated:5/10/2012

USACO

REFRIGERATEDCONTAINERGASCYLINDERHALIDETESTINGLOG
FLAME
TEST
DATE

DEPOT

LOCATION

CYLINDER
NUMBER

PASS/
FAIL

ConGlobalIndustries

Seattle,WA

CGISEA001

3/1/2012

Pass

MikeA

destructiondate:3/3/2012

ConGlobalIndustries

Seattle,WA

CGISEA002

3/1/2012

Pass

MikeA

destructiondate:3/3/2012

ConGlobalIndustries

Seattle,WA

CGISEA003 3/10/2012

Pass

MikeA

ConGlobalIndustries

Seattle,WA

CGISEA004 3/10/2012

Pass

MikeA

ConGlobalIndustries

Seattle,WA

CGISEA005 3/10/2012

Pass

MikeA

ConGlobalIndustries

Seattle,WA

CGISEA006 3/26/2012

Pass

MikeA

ConGlobalIndustries

Seattle,WA

CGISEA007 3/26/2012

Pass

MikeA

ConGlobalIndustries

Seattle,WA

CGISEA008

ConGlobalIndustries

Seattle,WA

CGISEA009

ConGlobalIndustries

Seattle,WA

CGISEA010

ConGlobalIndustries

Seattle,WA

CGISEA011

ConGlobalIndustries

Seattle,WA

CGISEA012

ConGlobalIndustries

Seattle,WA

CGISEA013

ConGlobalIndustries

Seattle,WA

CGISEA014

ConGlobalIndustries

Seattle,WA

CGISEA015

ConGlobalIndustries

Seattle,WA

CGISEA016

ConGlobalIndustries

Seattle,WA

CGISEA017

ConGlobalIndustries

Seattle,WA

CGISEA018

ConGlobalIndustries

Seattle,WA

CGISEA019

ConGlobalIndustries

Seattle,WA

CGISEA020

ConGlobalIndustries

Seattle,WA

CGISEA021

ConGlobalIndustries

Seattle,WA

CGISEA022

TESTERNAME

COMMENTS

15|Page

Version2.1Updated:5/10/2012

USACO

5.0 NEWSAFETYREQUIREMENTSFORSERVICINGR134AREFRIGERATED
CONTAINERS
Theinvestigation(s)ofthecontainersthathaveexplodedindicatethatoneofthepossibleconditionscausing
theexplosionsistheintroductionofafreshR134arefrigerantchargeintoacontaminatedsystem.Inan
efforttokeepourservicetechnicianssafe,withimmediateeffect,anyrefrigeratedcontainerusingR134a
refrigerantthatrequirestheconnectionofamanifoldgaugesetforanyreason,including::

AR134arefrigerantgascharge,
TheevacuationofR134arefrigerantgasforanyreason(i.e.systemrepair),OR
Simplepressurecheck.

willfirstberequiredtoundergoaRefrigerationgashealthandsafetycheck.Thisprocesswillentailthata
smallsampleofrefrigerantgasbeextractedbymethodscarefullydevelopedbyConGlobal,andfieldscreened
/testedbyeitherHalideflametestorbyRRAChloridetesttube.Thecostforthisfieldscreeningisminimal
andisavailabletoConGlobalclientsuponrequest.
(AvideooftheHalideflametestcanbeviewedathttp://youtu.be/JDBTxSJ7H8)
Theresultsforallrefrigerantsamplestestedwillbecommunicatedtotheclientsandwillberecordedwiththe
ConGlobalservicehistoryfortheunit.Iftherefrigerantgassamplepassesthefieldscreentest,thenour
servicetechnicianswillaffixaR134arefrigeranttestdecaltotheunit(seebelowformoredetails)andproceed
withthenormalserviceroutine.
However,anyR134arefrigerantgasfailingthefieldscreentestwillbesubjecttoaGasChromatography
MassSpectrometry(GCMS)openscanlabtestbeforeanyfurthermachineryrepairsarecarriedout.Thecost
toourclientforthisadditionalrequiredsafetytestwillnotbeincurreduntilapprovalbytheclientisreceived.
ThedetailedresultsoftheGCMSopenscanwillbeprovidedelectronicallytothecontainerclient/ownerfor
theirrecordsandwillalsobekeptintheunitservicefilesatConGlobal.
Note:GCMStestresultsindicatinganydetectablelevelsofR40(methylchloride),TrimethylAluminum(TMA),
Tetramethylsilane(TMS)oranyotherpyrophoricgasorsubstancewillresultintheunitbeingclassifiedas
potentiallydangerousandallserviceworkwillSTOPuntilconsultationwiththeownerregardingneutralization
measuresaretakenandtheaffectedcontainercanbesafelyreturnedtoserviceordestroyed.
ConsistentwithARI700refrigerantstandards,anyGCMSresultsindicating>.5%(1/2of1%)ofothernon
dangerouscontamination,i.e.R142b,R12,R22,etc.,willresultintheunitbeing1)completelyevacuated,
purged,orcleanedwithdrynitrogen,2)oilremovedandreplaced,3)anewfilterdrierinstalled,and4)the
systemrechargedwithnewR134arefrigerant.Afterrechargingtheunitandrunningitfor30minutes,another
refrigerantgasscreentest(HalideorRRATubetest)willbeperformedtoconfirmtheeffectivenessofthe
process.

16|Page

Version2.1Updated:5/10/2012

USACO

GCMStestresultsindicating99.5%R134aorbetter,withnodetectableamountsofR40,TMS,TMAorother
pyrophoricgassesorsubstances,willbedeemedsafeandroutineservicewillproceed.AsmallGASTEST
Placard,liketheonepicturedbelow,willbeappliedtoallcontainermachinerywhen:

Fieldscreentest=PASSOR
CGMStest=99.5%+R134a(withnodetectablelevelsofpyrophoricgas,orofR40,TMS,
TMA

ADDITIONALSAFEGUARDSIMPLEMENTEDATCONGLOBALINDUSTRIES
ConGlobalIndustries,Inc.hasalsodevelopedspecificpractices,policies,anddisciplinesdesignedtoprevent
theproliferationandspreadofcounterfeitorcontaminatedR134arefrigerantwhileservicingcontainersatall
ofourservicelocations.Thesepracticesinclude:

FlametestingandcreatingapapertrailforallnewandexistingstocksofR134arefrigerant,confirming
itspurityandthatitisfreeofchlorideatlevels>300ppm(thelevelofsensitivityforaflametest).

Aseriesofhygieneprotocolrequiringthenitrogencleansingandflameretestconfirmationof
servicegaugesandreusablerecoverybottles,whenpriorrefrigerantgaspurityiseitherunknownor
positivelyconfirmedbyflametestorRRAtesttocontainchloride.

Thedestructionanditsdocumentationofdestructionofalldisposable,nonrefillableR134abottles.
Thisisintendedtoensurethatthebottlesarenotretrievedandusedinthecounterfeitmarket.

Nomixingofrefrigerantfromoneunittoanother.Anyrefrigerantevacuatedandrecoveredfroma
container,afterflametesting,canonlybereturnedtothesamecontainerthatitwaswithdrawnfrom

17|Page

Version2.1Updated:5/10/2012

USACO

andwillnotbemixedwithrefrigerantfromanyotherunit.Ifforsomereasontherefrigerant
withdrawnfromaunitisnotreplacedinthesameunit,therefrigerantwillberecycled,reclaimedor
incineratedratherthanusedinanotherunit.ThispolicyisintendedtoincludeALLcontainersinEVERY
circumstanceincludingsaleandscraprefrigeratedcontainers,whereitiscommoninsomerepair
facilitiestoevacuatetherefrigerantwiththespecificintentofresale.

TheestablishmentandimplementationofarecordkeepingsystemforallR134arefrigerantsusedto
servicearefrigeratedcontainerthatcanbetracedbacktothebottleoforigin.Whencombinedwith
thenewbottletestingprotocoldescribedearlier,unitspecificservicerecordscaneasilybetracedback
toaflametested/purityprovenR134arefrigerantsource.

ThetrainingofeveryConGlobalrefrigerationservicetechnicianandpartsreceivingpersonnelastothe
characteristicsthatmightindicatearefrigerantcylindermaybeacounterfeitedproduct.

AsaconditionofemploymentatConGlobaloraffiliatedcompanies,everyservicetechnician,their
supervisors,andfacilityGeneralManagerswillacknowledgereceiptofthesepolicies;acknowledge
theircompleteunderstandingandtheintentionsofthesepolicies;andpledgetofollowtheprotocol
andrefrigeranthandlingprocedures.Additionally,thishandbookshouldbeincludedinthe
refrigerationpersonnelnewhirechecklist.

18|Page

Version2.1Updated:5/10/2012

USACO

6.0 CONGLOBALGASEXTRACTIONANDANALYSISRECOVERYSYSTEM
(CGEARS)

SAMPLINGMETHODS
ConGlobalsrefrigerationgassampling,testmethodology,andproceduresaredescribedinthisdocument.
1. Samplemethodtosafelyextractgasandtofieldcheckrefrigerationmachineryforchlorine
contamination.
2. TakingasamplefromarefrigerationmachineforlaboratoryanalysisMAIsampletube.

IMPORTANTPRECAUTIONS
Itisadvisableforalltechnicianstoconsiderthatarefrigerationmachinesystemmightbecontaminatedbefore
turningthepoweronandbeforeanyattemptismadetotakeagassample.
Currently,thesimplestandmostreliabletestfordetectingthepresenceofchloridecontaminationisthe
HalideFlameTest.Itshouldnotbeusedwithoutfollowingdetailedinstructionsandtakingsuitable
precautions.TheHalideFlameTestissensitivetoapproximately300ppmforchloride(0.03%)anditis
thereforelikelytodetectifasystemhasbeencontaminatedwithachloroalkanesuchasR40orHCFCssuch
asR22,R12orR142b.
ItshouldberememberedthatthetestisforchlorideandnotatestfortheverydangerousgasTMS
(Trimethylsilene)orTMA(Trimethylaluminium),whichifpresent,wouldbealiquidinthecrankcase.The
meltingpointofTMAis15oC.ItisremotelypossiblethatevenwhereaHalideFlameTesthasnotdetectedthe
presenceofchlorideinagassampletakenfromarefrigerationmachine,theremaystillbecontamination
residuesinthecompressorthatcouldbehazardous.Techniciansshouldremainvigilantandcautiouswhen
workingontherefrigerationsystem.
WhenrefrigerationsystemsarecontaminatedwithR40,harmfulchemicalsmayhavealsoformedinthe
system.Insomecases,thesechemicalsmayburnspontaneouslyinaironcontactwithwater.Techniciansare
advisedtowearprotectiveclothing,gloves,eyeprotection,keepingskincoveredasmuchaspossibleandto
avoidanycontaminatedchemicalcomingintocontactwiththeskinorbeinginhaled.
Todate,therehavebeenfourinstanceswherecompressorshaveexplodedwhilebeingworkedon.Itis
suspectedthatthismighthavebeenaresultofR134arefrigerantbeingintroducedintothecompressorduring
chargingorwhenthemachinepowerwasturnedonallowingrefrigeranttoreturntothecompressor.Other
suspectedconditionsthatmanyexpertssuspectmayleadtoexplosionsaretheintroductionofair,oxygenor
moistureintoacontaminatedsystem.Inaddition,unusuallyhighcompressortemperaturesand/orpressures
whilerunningshouldalsobeofseriousconcern,andmaycauseorcontributetoapotentialexplosion.

19|Page

Version2.1Updated:5/10/2012

USACO

Thereisapossibilitythatacontaminatedrefrigerationsystemcouldhaveanegativepressurerelativetothe
atmospherewhenitisnotrunning.Thiscanhappeniftherefrigerationsystemwascontaminatedwithalarge
amountofmethylchloride(R40).TheR40mighthavebeenconsumedbyachemicalreactionwithaluminium
componentsinthecompressor,thusreducingthepercentageofR40andthelatentpressureinthesystem.
Conversely,theextremehightemperaturesandpressuresthatacompressorcanreachwhilerunning,if
contaminatedwithcertainnon134arefrigerants,(whichhasbeensimulatedinlaboratoryconditions)isof
particularconcernandmayalsoberelatedtothepotentialexplosionofarefrigerationcompressor.

CGEARSMETHODTOCHECKREFRIGERATIONMACHINERYFORCHLORIDECONTAMINATION
Thistechniqueisintendedtoenableservicetechnicianstoquicklyandsafelycheckarefrigerationmachineina
typicalrepairdepotenvironmentforchloridecontaminationtodetermineifitissafetoworkontheunit.
Ifaunitiscontaminated,itispossiblethatthegasintherefrigerationsystemmayviolentlyreact,smoke,
combustorevenexplodewiththeintroductionofair,water,freshR134a,oranelectricalspark.

Itisveryimportanttoensurethatnoair,moisture,orwatercanenterintothesystemwhileextracting
gas.Similarlyitisimportantnottoallowanysystemrefrigeranttoleakintotheatmospherewhile
extractinggasforsampling&testingpurposes.

Allconnectionsmustbecompletelydry.

Priortotheextractionprocess,confirmtheunitisunpluggedbeforeproceeding.

Onsomesystemsthatarecontaminated,thesightglassmaybeadarkgreyorbrowncolorandnoteasytosee
into.Ifthisisthecase,extracautionshouldbetakenwhenremovingsamples.
PREPARATION
EnsureallconnectionsarecleananddryonboththeCGEARSextractiondeviceandrefrigerationmachinery.

Positiontherefrigerationunittobetestedfromtheflamesource.

Besuretodischargeanystaticelectricitybytouchingtheunitframeimmediatelypriortoextracting
thegassample.

Enforceanonsmokingzoneofatleast25.

ProvideaClassC(drypowder)andClassDfireextinguisherintheimmediateworkarea.

TechnicianshouldalwayswearPPEsafetyglassesandfaceshield,gloves,andhighvisibilityvest.

EQUIPMENT

CGEARSextractiondevice

Vacuumpump

Bottleofdrynitrogenwithregulator

20|Page

Version2.1Updated:5/10/2012

USACO

HFCR134aquickconnectors

Spannerwrench

MAIGassampletubewithPHpaper(availableatMcCampbellAnalyticalPittsbug,CA
www.mccampbell.com)

HalideflametorchandCGIventilationhood

SafetyglassesorFaceShield

ProtectiveGloves

21|Page

Version2.1Updated:5/10/2012

USACO

FIGURE1
CGEARSExtractionManifold

PREPARINGTHECGEARSDEVICE
1. Cleaningandflushingconnectthedevicetoaregulatedsupplyofnitrogenandpurge/flushtheC
GEARSdevicetocleananypreviouscontaminantsfromthedevice.
Note:itisveryimportanttoavoidanypossiblecrosscontaminationfromtheprevioustest,which
shouldbeconfirmedbyaHalideflametest,usingaknownsourceofpureR134a.
2. Pressuretest,withnitrogen,theCGEARSsystem(includingMAIsampletube)to6070psiandcheck
forleaks,thenreducetheregulatorpressureandsetat20psi.
3. PurgenitrogenfromCGEARSandconnectthedevicetoanewsupplyofR134a,knowntobefreeof
chloridecontamination,andtakearefrigerantsample.

22|Page

Version2.1Updated:5/10/2012

USACO

4. HalideflametestthissampleofknowncleanR134atoinsurethereisnochloridepresentintheC
GEARSdevice.
5. CheckthePHPapertoconfirmneutralPHlevelof4to8onthecolorscale.
6. EvacuateCGEARSintoavacuumof2930in/HG.Aftershuttingvacuumpumpoff,andclosingthe
quickconnectvalve,confirmvacuumismaintainedfor30seconds,confirmingnoleaksintheCGEARS
device.

TAKINGSAMPLESFROMREFRIGERATIONMACHINE
SAMPLEPORTS
GassamplescanbetakenfromeithertheHighPressure(HP)orLowPressure(LP)sideofanidleunitthatis
disconnectedfromapowersource.Therecommendedaccessportisgenerallydescribedasaserviceport
locatedasfarfromthecompressoraspossiblebothitsphysicallocationinproximitytothecompressorand
thefarthestpipingdistancefromthecompressor.Thisrecommendationisintendedtoallowservice
technicianstobeasfarfromthecompressoraspossible(physicaldistance)whileaffordingtheleastlikely
chanceofencounteringTrimethylAluminium(TMA),whichmayhaveformedinthecompressorandmigrated
tootherpartsoftherefrigerationsystem.InthecaseofaCarrierNTmachinetherecommendedaccessportis
theKingValve.
SAMPLINGPROCESS

Afterproperlycleaning,pressuretesting,andleakcheckingbyvacuum,thegassamplingprocesscan
begin.

TheCGEARSdeviceshouldbeina2930in/HGvacuum.

Choosetherefrigerationunitsamplingportbasedonthecriteriaabove(samplingports).
1. Ensureaccessportiscleananddry.
2. Withthequickconnectandservicevalvesclosed(backseated)attachthequickconnectvalveof
theCGEARStotheserviceport.
NOTE:IMPORTANTINFORMATIONRELATEDTOSCHRADERVALVES
AportionofintermodalrefrigerationunitsareequippedwithRefrigerationAccessValves,
commonlyreferredtoasSchraderValves,whichisonemanufacturerofthesetypesofvalves(see
photobelow).Thesevalvescanbefoundonthedischargeservicevalve,suctionservicevalve,and
atvariouspointsintherefrigerantplumbinglines.

23|Page

Version2.1Updated:5/10/2012

USACO


TheRefrigerationAccessValveisaflareconnectorfitting.Whenconnectingordisconnectingaline
fromaSchraderValveoranyotherbrandofRefrigerationAccessValve,adischargeofrefrigerant
isnormallyreleased.
SeeSchraderValveVideo:http://youtu.be/81DrmrzdQmM
IftheR134arefrigerantthatisdischargedhadpreviouslybeencontaminatedwithchloride
contaminants,thereisapossibilitythatotherdangerousgassesmayhaveformedandthata
pyrophoricreaction(spontaneousignition)orexplosioncouldoccurifgasisreleasedintothe
atmosphere.
Assuch,anytimeaSchraderValve,orsimilarRefrigerationAccessValveisbeingconnectedor
disconnected,thetechnicianmustfirstuseaquickconnectadapter,toavoidthelossofrefrigerant
intotheatmosphere(seephotobelow).ThequickconnectcouplercommonlyusedatCGIandour
affiliatedcompanies,canbepurchasedfromThermoKing.

24|Page

Version2.1Updated:5/10/2012

USACO


3. Keepingtheservicevalveclosed,openthequickconnectvalvetoensurethatanypossibleair
remainingintheconnectionareabepulledintotheCGEARSdevicevacuumandconfirmingthe
connectionisairtight.TheCGEARSshouldmaintaina28+HGvacuum.
4. Reclosequickconnectvalve.
5. Inadditiontothequickconnectvalve,ensurethetwoothervalvesontheCGEARSdeviceandthe
sampletubeareclosed.
6. Openservicevalve.
7. Openthequickconnectvalve.ThiswillallowgasatsystempressuretoflowintotheCGEARS.
Note:Ifavacuumismaintainedafteropeningthequickconnectvalve,closeallvalves(CGEARS
andserviceport)andcontactHQforconsultation.ThisconditionmayindicatetheRefrigeration
systemisinavacuum,aconditionlikelyindicatingthepresenceofdangerousgasses.DONOTrun
theunitorattempttoreusetheCGEARSdevice.
8. OpentheCGEARSstage2valveandtheMAIsampletubevalve.Ifsetcorrectly,theregulatorwill
let20psiofgasflowintothesampletube.
9. RecloseMAIsampletubevalvetrappingagassampleintheMAIsampletube.
10. Closetheservicevalve.
11. Closethequickconnectvalve.
12. DisconnecttheCGEARSandmoveawayfromtheunit.
13. WatchthePHpaperintheMAIsampletubefor30secondsforanyacidicreaction.Ifnoreaction
occurs,proceedwiththeflametest(Note:TheCGEARSgaugeshouldnowread20PSI).

25|Page

Version2.1Updated:5/10/2012

USACO


PHPaperChart.
Note:ThisisasampleofthePHpaperchart.RefertophysicalPHpaperforcolorcomparisonwithgassample.

26|Page

Version2.1Updated:5/10/2012

USACO

FLAMETESTINGOFEXTRACTEDSAMPLES
WithasampleofgassafelyextractedandtrappedintheCGEARSdeviceandtheMAIsampletube,aflame
testforchloridecontaminationcannowbeperformed.
1. ConfirmthatnoreactiontothePHpaperintheMAIsampletubehasoccurred.IfthePHpaperhas
reactedDONOTflametestthegassample.ContactHQforconsultationanddonotopenorreuse
theCGEARS.
2. ConfirmthattheMAIsampletubevalveisclosed.
3. AttachcapillarytubewithquickconnecttotheCGEARSquickconnectvalve.

27|Page

Version2.1Updated:5/10/2012

USACO

4. InaConGlobalHalideFlameteststationwithanegativeventilationfan,conductaHalideFlametestas
outlinedinConGlobalIndustriesflametest/bottletestsection.
Flametestingvideolink:www.youtu.be/JDBTxSJ7H8

Note:IftheCGEARSgaugereadsgreaterthan20PSI,slowlybleedatinysampleuntil20PSIis
achieved.ReopentheMAIsampletubevalveandreclosetoensure20PSIisintheMAIsampletube.
This20PSIreadingisaveryimportantQCmeasureforMcCampbellAnalyticalLab.
FLAMETESTRESULTS
Iftheflametestindicatesnochloridecontaminationover300PPM(BlueFlame)thentheCGEARSandthe
MAIsampletubecanbevacuumpurgedandreusedimmediatelyfortestinganotherunit(nonitrogenpurge
isnecessary,thoughrecommended).
Iftheflametestindicateschloridecontaminationat300PPMorgreater(GreenFlame),thenthesampleinthe
MAIsampletubeshouldbetaggedwiththecontainernumberandsenttoMcCampbellAnalyticalLaboratory
(MAI)forGCMSanalysis.Sampletubesshouldhavebrasscapinstalledassecondaryleakpreventionanda

28|Page

Version2.1Updated:5/10/2012

USACO

chainofcustodydocumentshouldaccompanyeachsample(multiplesamplescanbeincludedonasingleCOC
form.)Sampletubesshouldbeplacedinasealableplasticbag(asaddedleaksurety)andbesafelypackaged
andsentviaovernight(FedEXorDHL)toMcCampbellAnalyticalinPittsburg,Ca.
Note:McCampbellAnalyticalwillclean,verifyintegrity,andreturnsampletubestoCGIforreuse,aftereach
gasanalysis.
CLEANINGTHECGEARS
Afteranyfailedflametest(GreenFlame)itiscriticalthattheCGEARSbethoroughlycleanedanditschloride
freeconditionbeconfirmedpriortoreusing.Thisprocesswillgenerallytakelongerandbemoredifficultthan
imagined.Experienceindicatesthatthecleaningdifficultywilldependonthetypeandamountofchloride
contamination.Minorcontaminationcangenerallybecleanedwithtwominutesofnitrogenpurgingathigh
pressureandthreeminutesofvacuumcleaning,repeatingeachsteptwice.Moreseverecontaminationwill
takemoreeffort.
AftercleaningtheCGEARS,flametestaknowncleansampleofR134atoensurethedeviceischloridefree
andreadyforreusewithnopossibilityofafalsepositiveresult.

29|Page

Version2.1Updated:5/10/2012

USACO

7.0 EMPLOYEEACKNOWLEDGMENT
Ihavereadandfullyunderstandtheinformation,policiesandprocedures,andinstructionsoutlinedinthe
RefrigerationTechnicianHandbook.
Ifullyunderstandallthespecificissuesrelatedtoreceiving,handling,startup,bottletesting,gashandling,and
gasextractionmethodologiesreferencedinthehandbook.
IagreethatifIhaveanyquestionregardingthesepolicies,procedures,andinstructions,Iwillimmediatelyask
myimmediatesupervisorforadviceorinstruction.
Ifullyunderstandtheimportanceoffollowingallpoliciesandprocedurerelatedtorefrigerationservicework
andagreestonotcircumventanypolicy,procedureorinstructionfoundinthehandbook.
IacknowledgeIhavebeenfullyinstructedandtrainedinthenewproceduresoutlinedinthehandbook,and
furtheracknowledgeIunderstandthosepoliciesandprocedures.

______________________________________________________________________________
EmployeesName(Print)EmployeesSignature

_______________________________________________________________________________
LocationTodaysDate

_______________________________________________________________________________
SupervisorsNameSupervisorsSignature

________________________________________________________________________________
GeneralManagersNameGeneralManagersSignature

30|Page

Version2.1Updated:5/10/2012