Академический Документы
Профессиональный Документы
Культура Документы
CENTRIFUGAL PUMPS
V-AN
CONTENTS
PROPERTIES OF THE V - AN
FUNCTIONAL PRINCIPLES
CONSTRUCTIONAL DESIGNS
23
APPLICATIONS
Condensates
Drainage of steam lines
Tanker unloading from below
Tanker unloading from above
Residual emptying
Belt filter
Centrifuge
Columns
Evaporation plant
Chemical waste waters from collecting vessels
Thickener over flow
Slag cooling water
Chemical waste waters in pits
Slop tank emptying
24
CONVEYOR SYSTEMS
10
11
12
13
14
15
16
17
18
19
20
21
22
PROPERTIES
DIFFERENT FROM
OTHERS.
THE SELF - REGULATING
CENTRIFUGAL
PUMP V-AN.
2 3
ADVANTAGES.
APPLICATION AREAS.
PERFORMANCE.
FUNCTIONAL PRINCIPLES
H
Q out
Intake Q in
HZ
C1
A1
SIMPLE
AND EFFICIENT.
THE FUNCTIONAL
PRINCIPLES OF THE
PUMP AN.
2gHz A1 =
Q in
K< 1
K = f (pump and rotation speed)
The liquid level rises when a medium flows into the vessel.
It rises until the intake rate is exactly equal to the outflow
rate. On condition that the vessel is high enough, an equilibrium will always be established.
This regulating principle is simple and ingenious. It
functions without requiring any mechanical or electrical
regulating device also with pumps of type V-AN.
4 5
H
Plant characteristic line
Q Limit
Characteristic line
of a normal priming
centrifugal pump
Hstat
HZ limit
HZ3
HZ1
HZ4
HZ2
P R I N C I P L E . The V-AN models operate in a selfregulating manner, depending on the intake rate. These
pumps do not have any priming capability. Their capacities
correspond to the volume intake rate. This determines
the liquid column height HZ in the intake vessel.
The manner in which the V-AN feeds the medium
can be described by a family of cur ves (parameter HZ =
constant). This family of curves is limited at the top by the
characteristic line of a normal pump. The deliver y height
and the volume intake rate determine how high the liquid
stands in the intake vessel. The working point on the
plant characteristic line always lies between zero feed
rate and Q limit (Q limit is the intersection point of the plant
characteristic line and the characteristic line of the normal priming centrifugal pump). HZ limit varies between 0.5
and 2.0 m depending on the pump size and the rotation
speed. With regard to HZ limit the V-AN behaves like a normal sucking pump. Their NPSH value is 0. Thus they operate without cavitation, provided that undershoot of the
vapour pressure in the intake vessel is avoided.
Gas bubbles entering the pump will be par tly conveyed. But par tly they will also be returned via a gas
balance line into the intake vessel. If nothing flows into
the priming container, the pump maintains the static
head of the plant at zero deliver y. As far as the technical
prerequisites are concerned, the V-AN can be operated
for any length of time with Q = 0 m3/ h. Thereby the temperature increase of the pumping medium must not
impair the corrosion behaviour of the material.
Impeller back vanes relieve the secondar y sealing
of the pump (e. g. gland packing or double mechanical
seal DMS) completely, i. e. hydrodynamically. This is also
the reason why in the variant with gland packing, medium
can never escape via the shaft seal to the exterior. However, for this the pump must be star ted and stopped correctly. The V-AN can also be rinsed with flushing water fed
in via the infeed connector before switching the pump off.
CONSTRUCTIONAL DESIGNS
VERY GREAT
DIVERSITY.
THE VERSIONS AND
VARIANTS.
VK-AN
6 7
MPV-AN
MPCV-AN
T-AN
MPAT-AN
dr y set-up
with magnetic drive and liquid lubricated
slide bearings
hermetically sealed
zero feed rate safe
MPCV-AN, with magnetic drive
dr y set-up
hermetically sealed
no bearing in the pumping liquid
safe to run dr y
APPLICATIONS
FLEXIBLE
UTILISATION.
APPLICATIONS.
SHAFT SEALS.
TYPE)
SEAL (PUMP
DED SHAFT
RECOMMEN-
MEDIA
TYPICAL
column
H = m liquid
Q = m 3/h
APPLICATIONS
FORMANCES
TYPICAL PER-
8 9
Condensates,
atmospheric
approx. 100 C
Q = 0 300
water /
VKS
e. g. drainage
vacuum
< 100 C
H = 10 80
hydrocarbons
of steam lines
overpressure
> 100 C
Tanker
from below
environment
unloading
from above
environment
liquefied gases,
H = 10 40 (100)
H2SO4
Q = 0 50
H2SO4, oleum,
H = 10 40
up to densities of
MP, VKG
2.3 kg /dm3
Residual emptying
pipelines
environment
vessel
Centrifuge /
VKG, VKA, MP
Q = 0 350
refiner y products,
VKG, VKA
H = 10 60
liquid chemicals
Q = 0 75
liquid chemicals,
H = 10 40
Q = 0 50
liquid chemicals,
H = 15 40
VKA
H = 10 30
(stripping pump)
Belt filter
liquid chemicals
Q = 0 10
vacuum
atmospheric
environment
environment
environment
Decanter /
Filter press
Columns
vacuum /
up to 300 C
overpressure
Evaporation plant
vacuum /
vacuum to
overpressure
VKG, VKA, MP
H = 10 30
up to 300 C
overpressure
Chemical waste
Q=05
up to 200 C
Q = 60 100
fatty acid,
H = 10 30
liquid chemicals
VKG, VKA, MP
Q = 0 500
H = 10 30
Q = 0 1.200
T-AN,
H = 10 30
Stopfbuchse,
collecting vessel,
e.g. thickener overflow,
slag cooling water
Chemical waste
atmospheric
up to 100 C
Wasserringsperre
Slop tank
emptying
atmospheric
up to 250 C
Q = 0 30
H = 10 60
MPAT
APPLICATIONS
Ring line
Q in
(fluctuating)
Q out
HZ
HARDLY
ANY SPACE.
THE
CONDENSATES.
Q = 0 300 m3/ h
H = 10 80 m
10 11
HZ
LOW INSTEAD
OF HIGH.
DRAINAGE
OF STEAM LINES.
no NPSH problems
low constructional heights are possible
no regulating problems,
not even with small feed rates
safe to run dr y
PERFORMANCE PARAMETERS.
Q = 0 3 m 3/ h
H = 40 m
APPLICATIONS
Infeed pipe
reduced pressure safe
STAY ON
THE GROUND.
TANKER UNLOADING
FROM BELOW.
Liquid level
after emptying
H Z = 0 mm
The NPSH values are ver y low when tankers with boiling
liquids are emptied. This often makes it necessar y to
use pot pumps or pit installations. The self-regulating
pump AN can be installed on ground level beside the
tanker. It is then possible to empty the tanker and the
hose connector completely without any problems.
ADVANTAGES.
Q = 0 50 m3/ h
H = 10 40 m
12 13
P1
Volume of the
suction line VS
Return flow
volume VZ
Suck-in volume V1
(vessel reduced pressure safe)
STANDING
ABOVE THINGS.
TANKER UNLOADING
FROM ABOVE.
Minimum
level
HZ = 0
Q = 0 50 m3/ h
H = 10 40 m
APPLICATIONS
Scrubber sump
min.
Q = 0 350 m3/ h
H = 10 60 m
14 15
Vacuum pump
Vacuum
HZ
Q = 0 75m3/ h
H = 10 40 m
APPLICATIONS
HZ
FITTING BY
ADAPTATION.
THE CENTRIFUGE.
PERFORMANCE PARAMETERS.
Q = 0 50 m3/ h
H = 15 40 m
16 17
HZ
min.
QUITE
SMALL.
THE COLUMNS.
HZ
PERFORMANCE PARAMETERS.
Q = 0 5 m 3/ h
H = 10 30 m
APPLICATIONS
Infeed
Circulation
L1
Feed-out
Vacuum
PD TD
HZ
CIRCULATING
EVENTS.
THE EVAPORATION
PLANT.
Q = 60 100 m3/ h
H = 10 30 m
18 19
max.
normal
HZ
min.
PERFORMANCE PARAMETERS.
Q = 0 1.200 m3/ h
H = 10 30 m
APPLICATIONS
Sedimenter
clarifier
Flocculating vessel
Gas
balance
line
from
precipitating vessel
HZ
HZ
Self-regulating
intermediate feed pump
CONTAINS
WITHOUT VESSEL.
THE THICKENER
OVERFLOW.
Self-regulating
clean water pump
Q = 0 500 m3/ h
H = 10 30 m
20 21
Slag
Steam generator
slag
Cooling water
Slag bunker
Waste water
treatment plant
Over flow
Ventilation
Gas balance line
max.
Over flow
min.
Pp.2
PERFECT
COLLECTING VESSEL.
THE SLAG
COOLING WATER.
V2
V1
Pp.1
APPLICATIONS
DN 400/500
DN 700
max
1000
min
DN 1200
2400 m3/ h
2500
EVERYTHING
UNDER CONTROL.
THE CHEMICAL
WASTE WATERS
IN THE PIT.
PERFORMANCE PARAMETERS.
Q = 0 1.200 m3/ h
H = 10 30 m
22 23
HZ
FIT IN
ALL FIELDS.
SLOP TANK
EMPTYING.
hermetically sealed
safe to run dr y
maintenance-free
complete emptying of the vessel
all-purpose, even in strongly contaminated media
also suitable for the Ex-Zone-0
for immersion depths up to 5.5 mm
PERFORMANCE PARAMETERS.
Q = 0 30 m3/ h
H = 10 60 m
24
CONVEYOR SYSTEMS
N2
HZ max.
AS COMPLETE AS
COMPACT.
THE BUNGARTZ
CONVEYOR SYSTEMS.
Bungar tz conveyor systems (FSV) are extremely spacesaving. They do not require control/regulation or additional
monitoring.
A complete solution can be delivered for the medium per formance ranges consisting of the pump, the
pump stand and the intake vessel (see the configuration
in Figure ...). This system does not require monitoring, by
vir tue of the pumps safe to run dr y. Even with zero feed
rate there is no risk of overheating. The reason for this is
the gas balance line which prevents pressure increase
inside the pump.
ADVANTAGES.
no
no
no
no
SYSTEM.
PRODUCT RANGE.
Horizontal pumps
Tank pumps
MATERIALS.
V- AN/ 09_ e