Vigilohm: functions and characteristics

044144

Vigilohm System:
XD301 and XD312 automatic insulation fault detectors

E19500

basic function
local fault detection

MERLIN GERIN
XD312

test

10 11 12
reset

3 2 4

1. lights indicating the faulty circuit.


2. selector to enable or disable transient
fault indication latching
3. sealable cover.
4. general fault indicator light.
5. test button for indicator lights and output
relay.
6. reset button (to clear fault indications).

installation and connection

XD301 and XD312 insulation fault detectors


have two functions:
c fault detection (with respect to the fault
threshold);
c automatic locating of the faulty circuit.

c live parts in an insulated case with a


sealable transparent cover. Width equal to 8
(XD301) or 12 (XD312) 9 mm width
modules;
c horizontal flush or surface mounting on
DIN rail;
c tunnel terminals for 1.5 mm2 wires.

operation

toroids

c XD301 and XD312 insulation fault


detectors are fixed receivers used with (but
not connected to) XM300C, XML308/316
and XM200 insulation monitoring devices.
Via measurement toroids, they detect and
automatically locate insulation faults
c the XD312 detector, with 12 channels
connected to a maximum of 12 toroids
installed on different circuits of the
installation, includes the following features
on its front face:
v 12 fault indicator lights corresponding to
the 12 channels,
v a selector to enable or disable latching of
transient fault indications until reset;
c detector XD301 is a single-channel
version designed for use with one
measurement toroid.

XD301 and XD312 insulation fault detectors


operate with type A and OA toroids. They
are also compatible with the older type N
and O toroids.

insulation fault detectors


electrical characteristics

XD301

type of installation to be monitored


operating threshold
polling time
fault indications

low voltage AC 45-400 Hz / DC


2.5 mA at 2.5 Hz (1)
20 s
20 s per channel
1 indicator light
12 channel indicator
lights (+ 1 general)
for indicator lights and output relay
reset button on device
on/off via selector
1 failsafe
3A
5A
0.45 A
0.65 A
2.5 A
10 A
115/127 V AC
220/240 V AC
380/415 V AC
500/525 V AC
- 15 % to + 10 %
6 VA
2500 V
none

local tests
clearing of indications
latching of transient fault indications
output relay
number of contacts
breaking capacity AC 400 V p.f. = 0.7
of output contacts
230 V p.f. = 0.7
DC 220 V L/R = 1 ms
120 V L/R = 1 ms
48 V L/R = 1 ms
24 V L/R = 1 ms
auxiliary
50/60 Hz
supply voltage

auxiliary supply voltage tolerances


consumption
dielectric strength
connection with insulation monitoring device

XD312

mechanical characteristics
weight
plastic case
degree of protection flush/surface mounting

0.3 kg
horizontal mounting
IP 30 / IP 20

0.6 kg

other characteristics
temperature range storage
operating
types of toroid to be used
toroid for direct connection to case

- 25 C to + 70 C
- 5 C to + 55 C
A, OA (N and O compatible)
30 and 50 mm
none
type A toroid

(1) The operating threshold of the XD301/312 detectors is not adjustable. These devices are designed to detect low-impedance
faults. The detection threshold varies between 100 and 2 k depending on the characteristics of the installation.

32

Vigilohm: functions and characteristics

XRM mobile fault locating receiver


and current probes
051350

operation
The XRM mobile receiver, used with a
current probe, is mainly intended as an
enhancement to automatic fault locating
systems. It can be placed at various points
along a faulty circuit, capturing the signal
emitted by an XM300C, XML308/316 or
XM200 insulation monitoring device to
determine the exact location of the fault.
Three current probes are available, the
XM15, XP50 and XP100.
The set of live conductors to be tested must
have a maximum diameter of 12, 50
and 100 mm respectively.

XRM receiver

display

PB100471

DB101070

The XRM receiver displays a number


from 0 to 19, corresponding to the insulation
level:
c 0: no fault;
c 19: solid fault (no insulation).

XP15, XP50 and XP100 current probes.


Note: the photographs are for information purposes only.
There are two types of probes that function in the same
way but are different in shape and colour.

DB100959

interfaces

MERLIN GERIN

MERLIN GERIN

MERLIN GERIN
v ig ilo h m s y s te m

v ig ilo h m s y s te m

v ig ilo h m s y s te m

XTU300

X L I3 0 0

XAS

f a

f a

f a

insulation monitoring

E24555

insulation monitoring
MERLIN GERIN
v ig ilo h m s y s te m

MERLIN GERIN

MERLIN GERIN

v ig ilo h m s y s te m

v ig ilo h m s y s te m

X M200

XM 300c

X M L 3 16
test

test

test

1 0

1 1

1 2

1 3

1 4

1 5

1 6

valeur d'isolement
040 K
MENU
TEST

valeur d'isolement
040 K
MENU
TEST

Sp
S

menu

ok

test

insulation
fault detection and locating

insulation fault
detection and locating
XD30

XD31

XD301

XRM

XD312

XRM

XD308c XL308 / 316


MERLIN GERIN

MERLIN GERIN

v ig ilo h m s y s te m

v ig ilo h m s y s te m

XD308c

XL316
test

test

MERLIN GERIN

MERLIN GERIN
1

v ig ilo h m s y s t e m

X D 301

MERLIN GERIN

v ig ilo h m s y s t e m

MERLIN GERIN
1

v ig ilo h m s y s t e m

X D 312
te s t

te s t

10

11

12

X D 301

1 0

1 1

1 2

1 3

1 4

1 5

1 6

8
on

v ig ilo h m s y s t e m

X D 312
te s t

te s t

10

11

12

test

reset

re s e t

re s e t

re s e t

re s e t

test/reset
5 0 5 0 7

P 5 0

P 5 0

5 0 5 3 6

P 1 2

o n

P 1 0 0

5 0 5 0 7

P 1 2

o n

5 0 5 3 6

P 1 0 0

MERLIN GERIN

MERLIN GERIN

v ig id ix

v ig id ix

R M

1 0 N

R M

1 0 N

sensors

sensors
MERLIN GERIN
G O

MERLIN GERIN
G O

S1

S2

S1

S2
MERLIN GERIN

MERLIN GERIN

S1

S2

S1

MERLIN GERIN
v ig ir e x

MERLIN GERIN

- v ig id ix
v ig ir e x

- v ig id ix

S2

MERLIN GERIN
v ig ir e x

MERLIN GERIN

- v ig id ix
v ig ir e x

MERLIN GERIN
v ig ir e x

- v ig id ix

MERLIN GERIN

- v ig id ix
v ig ir e x

- v ig id ix

33

Вам также может понравиться