Quick Reference Guide


Steam Generation
Exterior Cleaning
Interior Cleaning
Indoor Use

( 3 P H A S E E L E C T R I C P O W E R E D ) A L L S TA I N L E S S S T E E L S T R U C T U R E **

he Optima EST3 [S] Steamer is an improved all stainless steel, vapor-steam generator specifically

designed for [S]anitization. Using the latest in vapor-steam technology, the Optima can quickly and effectively
sanitize thermally, remove dirt, stains, grease, odors and other contaminants from a variety of surfaces. The
Optima EST3 [S] Series is available in three models; EST3 [S-12k], EST3 [S-18k] and EST3 [S-27k].
( Models differ based on electrical configuration. )

Cleaning Applications:
Sanitize food and beverage equipment
Food & beverage equipment and production lines
Remove bacteria, yeast, molds and fungi
Park and recreational equipment
Medical and Hospitality
Heavy equipment cleaning and maintainence
Clean cars, trucks, motorcycles, boats, golf carts,
small planes, machinery and general surfaces
Benefits:
Sanitize surfaces with 99.9% efficacy
Quickly and easily remove dirt, stains and grease
Reduce water and chemical consumption
Eliminate waste-water
Easy to maintain and operate
All day use

Optima Steamer EST3[S]


Features:
Adjustable Moisture Control Valve

Easily adjust the moisture level of steam.

Unique Boiler Design

Capable of achieving saturated (dry) steam with a short pre-heating time

Extended Hose Length

Over 65 (20m) of hose length.

Efficient Insulation

The Optima EST is equipped with the most heat efficient electric steam boiler. The boiler
quickly produces steam. The boilers unique vessel and insulation design supports a long life
span and keeps the machine cool during extended use.

Safety

Safety features include an LED illuminated control panel with corresponding alarm,
automatic shut-offs, pressure sensor, mechanical pressure release valve, automatic air
purge, thermostat control, water tank level sensor, high and low boiler water level sensors,
multiple check valves and a dry-run prevention setting on the water pump. Built in
accordance with UL, CSA and CE.

Ease of Use

No installation required. Factory tested and ready to use. Automatic operation.


Low maintenance.

Specifications:

Optima EST3
(S-12k)

Optima EST3
(S-18k)

Optima EST3
(S-27k)

Rated Electric Power

12,200 Watts

18,040 Watts

27,040 Watts

No. of Heaters

2 x 6kW

2 x 9kW

3 x 9kW

Amperage (Amp)**

Varies per voltage

Voltage (V)

208V, 220V-240V, 380V, 460-480VV

380V, 460V

Phase

Three (3) phase

Direct Water Hook-up

Automatic filling feature enabled with a floater switch


and a reservoir tank to regulate inlet water pressure

Boiler Vessel

3.83 gal (14.5L)

3.83 gal (14.5L)

5.15 gal (19.5L)

Pre-heating Time

8~9 minutes

6~7 minutes

6~7 minutes

Evaporation Rate

80 lb/hr (36.3kg/hr)

118 lb/hr (53.5kg/hr)

176 lb/hr (79.8kg/hr)

Working Pressure (psi)

Preset at 116psi with differential allowance of 14.5 psi

Boiler Temp

346F (174C)

Temperature at Gun Tip

248F (120C)

Steam Temperature [Sprayed]


Net Weight [Empty]

Depends on the distance from the gun tip, Max <212F (<100C) at 0
175 lbs (79.5kg)

183 (83kg)

Net Dimensions

194 (88kg)

30.7 x 19.7 x H30 (78cm x 50cm x H76.2cm)

Dual Hose Option

Yes

Hose Lengths

Standard hose length in 33(10m) 50(15m), 65(20m)

Gun Nozzle Lengths

Standard nozzle length: 2.65 (6.73cm)


Available extended nozzle length: 12 (30cm), 18 (45cm), 40 (100cm)
Customization and private labeling available pending minimum order quantity.

x1

x1

x2

x4

x1

x4

Recommended
Accessories:
*included with
Optima

x1

EST3 (18k, 27k)


EST3 (12k)

Steamericas, Inc.
808 Hindry Ave. Suite E.
Inglewood, California 90301

(310) 327-8900

www.steamericas.com

Вам также может понравиться