EMC-tested
DIN EN ISO 9001
Illustration shows variant without acoustic cladding
Fields of Application
F
F
F
F
Residential buildings
Hospitals
Office buildings
Hotels
Design
F Department stores
F Industry
F and other applications
Fluid Handled
Operating Data
Capacity Q
Discharge head H
Temperature of
fluid handled
Ambient temperature
System discharge
pressure pd
Inlet pressure pvor
Supply voltage
*)
Materials
Pumps
Suction/discharge
casing
Hydraulic system
Mechanical seal
Spring-loaded ring
Seat ring
Elastomer
Hydraulic design
Distributor pipe
Valves
Accumulator
Membrane
Drive
stainless steel
stainless steel
to EN 12756
silicon carbide
hard carbon
EPDM
stainless steel
copper-base alloy/brass, DVGW-approved
connection made of stainless steel
approved for drinking water to DIN 4807-5
Hyamat V
Standard scope
Extended scope
cf. supplementary equipment
Settings
Set pressure
Inlet pressure > 0.5 bar
Indications
Actual pressure
Pressure gauge
FI operation
NO contact
NO contact
NC contact
Lack of water
FI fault
NC contact
NC contact
NC contact
NC contact
Fault acknowlegement
Display:
may be set to daily or weekly
Display:
may be set to daily or weekly
Miscellaneous
Automatic ON-OFF
Second set value
Emergency OFF
Remote cancellation
Functional check run
Pump change-over
Limitation of number of pumps
Automatic ON-OFF
Second set value
Emergency OFF
Remote cancellation
Functional check run
Pump change-over
Limitation of number of pumps
Hyamat V
Hyamat
4/
Type series
Number of pumps
Pump size
Number of stages
Min. inlet pressure in bar
Max. effective inlet pressure in bar
Function
FI operation
Optional
Optional
Designation
FI fault
Emergency OFF
Pressure switch,
discharge pressure
Flow monitoring,
suction side
Immersion electrodes
Pump change-over
Remote cancellation
Automatic ON/OFF
Terminal Connections
Manual mode
Commissioning
Hyamat V
System Features with Movitec 2, 4 and 10
Equal distribution of
pump operating hours
by automatic pump
change-over
Acoustic cladding
(supplementary equipment)
- Retrofittable and easy to
service
- Protects against
contamination
- Appealing design
- Low-noise operation,
approx. 51 - 61 dB(A)
Manual-0-automatic
selector switch per pump
Display
(supplementary equipment)
- Operating hours counter
- Flow rate indicator
Automatic matching to
the demand
thanks to a continuously
speed-controlled base
load pump
Control tank,
(accumulator),
direct flow,
to DIN 4807-5,
DVGW-approved
DVGW-tested valves
Corrosion-resistant
stainless steel piping
Movitec Features
Reliable, service-friendly
shaft seal
- Standardised mechanical seal to
EN 12756
- High-alloy steel shaft
Low noise,
since the flow noise is damped
by water-filled shroud
Corrosion resistant
All wetted components, hydraulic
components and pump shroud are
made of high-alloy stainless steel
Hyamat V
System features with Movitec 18, 32 and 45
Equal distribution of
pump operating hours
by automatic pump
change-over
Acoustic cladding
(supplementary equipment)
- Retrofittable and easy to service
- Protects against contamination
- Appealing design
- Low-noise operation
Manual-0-automatic
selector switch per pump
Display
(supplementary equipment)
- Operating hours counter
- Flow rate indicator
Automatic matching
to the demand
thanks to a continuously
speed-controlled
base load pump
Control tank
(accumulator),
direct flow,
to DIN 4807-5,
DVGW-approved
Corrosion-resistant
stainless steel piping
Movitec Features
Reliable, service-friendly
shaft seal
- Standardised mechanical seal to
EN 12756
- High-alloy steel shaft
Low noise,
since the flow noise is damped
by water-filled shroud
Corrosion resistant
All wetted components, hydraulic
components and pump shroud are
made of high-alloy stainless steel
Hyamat V
Modes of Operation
Cascade: Hyamat K
Variable: Hyamat V
A base load pump is continuously controlled, with the peak load pumps being
started up and switched off in line with
the demand.
Set value
Modes of Connection
Direct
Indirect
Indirect
- float switch
- set of electrodes and relay
- dry-running protection set for
PE inlet tank
- flow monitoring
non-self-priming pumps; suitable for suction-lift operation (for selection, please consult KSB).
flow monitoring
float switch
set of electrodes and relay
dry-running protection set for
PE inlet tank
Hyamat V
Work sheet for selection
Basic data:
H
= (pE - pvor) 10
m
= pvor + (H : 10)
bar
pE
pmax = pE +0.4
bar
= PBU capacity at pE
m3/h
Qsoll
H
= PBU discharge head at Qsoll
m
= Start-up pressure for PBU at Qsoll
pE
including inlet pressure pvor
pvor
= Inlet pressure upstream of PBU
H0
= PBU discharge head at Q = 0
p0max = PBU discharge pressure at Q = 0 (=H0 + pvor)
Selection example
Requirement
Q = 20 m3/h, pE = 6 bar, pvor = 0
Found solutions to DIN 1988, part 5
1. Hyamat V 6/0408/0
2. Hyamat V 5/0409/0
With any of the two above systems, the
set pressure level can be obtained at
20 m3/h.
They differ as to the possible inlet pressure fluctuations.
6 bar
including a
stand-by
pump to
DIN 1988
2
1
Hyamat V
Hyamat V Performance Chart (Complete Overview)
Hyamat V
Movitec 2
Movitec 4
Movitec 10
Movitec 18
n = 2900 1/min
Hyamat V
Movitec 32
10
Movitec 45
n = 2900 1/min
Hyamat V
Characteristic Curves Movitec 2
pvor = 0
p0 max = 16 bar
pA = max. switch-off pressure
including a
stand-by
pump to
DIN 1988
11
Hyamat V
Characteristic Curves Movitec 4
pvor = 0
p0 max = 16 bar
pA = max. switch-off pressure
12
including a
stand-by
pump to
DIN 1988
Hyamat V
Characteristic Curves Movitec 10
pvor = 0
p0 max = 16 bar
pA = max. switch-off pressure
including a
stand-by
pump to
DIN 1988
13
Hyamat V
Characteristic Curves Movitec 18
pvor = 0
p0 max = 16 bar
pA = max. switch-off pressure
14
including a
stand-by
pump to
DIN 1988
Hyamat V
Characteristic Curves Movitec 32
pvor = 0
p0 max = 16 bar
pA = max. switch-off pressure
including a
stand-by
pump to
DIN 1988
15
Hyamat V
Characteristic Curves Movitec 45
pvor = 0
p0 max = 16 bar
pA = max. switch-off pressure
16
including a
stand-by
pump to
DIN 1988
Hyamat V
Accessories / Supplementary Equipment *) Hyamat V
Dry-running Protection Equipment
E No.
Ident. No.
Retrofit
option 1)
E 400
18 040 613
Retrofit
option 1)
E 410
18 040 614
Retrofit
option 1)
as separate
switchgear
E 201
19 070 923
Retrofit
option 1)
if sufficient
space available
in control
cabinet
E 420
00 198 098
00 533 947
18 040 615
11 037 630
11 037 631
11 037 632
11 037 743
11 037 744
11 037 746
5m
10 m
20 m
19 071 650
19 070 395
19 071 651
76
76
E No.
Ident. No.
Multi-line display,
Indications and set values using keyboard
E 511
19 072 450
E 340
E 341
Always combined
*) Accessories (Ident. No.) are included in the scope of supply but not fitted.
Supplementary equipment / options (E No.) come fitted to the unit.
17
Hyamat V
Accessories / Supplementary Equipment *) (continued)
E No.
Ident. No.
E 330
E 040
18 040 617
E 050
18 040 618
E 051
E 360
19 071 510
Acoustic cladding 2 / 4 / 10
- Protects against contamination
- Appealing design
- Low-noise operation, appr. 51-61 dB(A)
Number of pumps
2 E 120
3 or 4 E 121
5 or 6 E 122
18 040 610
18 040 611
18 040 612
Number of pumps
2
3
4
5
6
E 123
E 124
E 125
E 126
E 127
19 071 633
19 071 634
19 071 635
19 071 636
19 071 637
2
3
4
5
6
E 128
E 129
E 130
E 131
E 132
19 071 663
19 071 664
19 071 665
19 071 666
19 071 667
Telecommunications module,
for fault signalling via telephone lines, with battery buffer
E 043
19 072 308
E 058
E 059
E 039
E 320
Over-voltage protection
E 060
E 061
24
36
Hyamat 18 up to 7.5 kW
Hyamat 32 and 45 up to 15.0 kW
- Protects against contamination
- Appealing design
- Noise reduction
*) Accessories (Ident. No.) are included in the scope of supply but not fitted.
Supplementary equipment / options (E No.) come fitted to the unit.
18
Hyamat V
Supplementary Equipment (on request)
Control cabinet equipment
Volt-free individual indications on special isolating terminals
Emergency power connection with automatic activation
Motors with PTC resistors and PTC resistor trip device in the control cabinet
Switch position indication for master switch and manual-0-automatic selector switch
Control cabinet with cylinder lock
Special painting
Extra space in control cabinet
Control cabinet air-conditioning
Communication via an RS 232C interface
Profibus / LON bus interface
Indications for control station (on isolating terminals)
Operating pressure, analog 4 - 20 mA
Operating pressure, digital, volt-free
Inlet pressure, analog 4 - 20 mA
Power input for each pump, analog (e.g signal 0/4 - 20 mA / 0 - 10 V)
Position of manual-0-automatic selector switch per pump, volt-free
Special designs
Other special designs not documented are available upon request, e.g.:
1. Different operating voltage
2. Different frequency
3. Different connection diameters
4. System discharge pressure pd up to 40 bar
5. Systems for industry (for example, also for other fluids)
6. Systems for suction-lift operation
7. System combination with central control system etc.
8. Electro-mechanical control units
9. Jockey pumps: low-flow operation (on weekends, in case of extremely fluctuating demand etc.)
10. Combined systems (drinking water and fire-fighting systems), booster systems
11. Customer-specific special circuit diagrams
Remote control from control station
Setting of basic set value via warning signal (0 - 10 V)
19
Hyamat V
Electrical Performance Data
Hyamat V
with Movitec
pumps
Rated power
per motor (P2)
kW
Rated current
per motor for
3~400 V
A
0202
0203
0204
0205
0206
0207
0208
0209
0210
0211
0213
0215
0.37
0.37
0.55
0.55
0.75
0.75
1.1
1.1
1.1
1.1
1.5
1.5
1.4
1.4
1.5
1.5
2.1
2.1
2.9
2.9
2.9
2.9
4.4
4.4
5.78
5.78
6.06
6.06
7.72
7.72
10.24
10.24
10.24
10.24
14.99
14.99
6.80
6.80
7.15
7.15
9.22
9.22
12.30
12.30
12.30
12.30
18.09
18.09
0402
0403
0404
0405
0406
0407
0408
0409
0410
0411
0413
0415
0.37
0.55
0.75
0.75
1.1
1.1
1.5
1.5
1.5
2.2
2.2
2.2
1.4
1.5
2.1
2.1
2.9
2.9
4.4
4.4
4.4
6.0
6.0
6.0
5.78
6.06
7.72
7.72
10.24
10.24
14.99
14.99
14.99
20.43
20.43
20.43
6.80
7.15
9.22
9.22
12.30
12.30
18.09
18.09
18.09
24.63
24.63
24.63
1002
1003
1004
1005
1006
1007
1008
1009
1010
0.75
1.1
1.5
2.2
2.2
3.0
3.0
4.0
4.0
2.1
2.9
4.4
6.0
6.0
7.0
7.0
9.0
9.0
7.72
10.24
14.99
20.43
20.43
24.40
24.40
31.44
31.44
9.22
12.30
18.09
24.63
24.63
29.30
29.30
37.73
37.73
1802
1803
1804
1805
1806
1807
1808
1810
2.2
3.0
4.0
5.5
5.5
7.5
7.5
11.0
6.0
7.0
9.0
11.8
11.8
14.3
14.3
26.6
6.81
8.50
11.09
14.53
14.53
21.46
21.46
35.78
11.01
13.40
17.37
22.75
22.75
31.41
31.41
54.26
15.22
18.30
23.66
30.98
30.98
41.37
41.37
72.74
19.43
23.20
29.94
39.20
39.20
51.33
51.33
91.22
23.63
28.10
36.23
47.43
47.43
61.29
61.29
109.70
3202
3203
3204
3205
3206
3207
3208
4.0
5.5
7.5
11.0
11.0
15.0
15.0
9.0
11.8
14.3
26.6
26.6
31.7
31.7
12.59
17.53
21.46
35.78
35.78
45.01
45.01
18.87
25.75
31.41
54.26
54.26
67.02
67.02
25.16
33.98
41.37
72.74
72.74
89.04
89.04
31.44
42.20
51.33
91.22
91.22
111.05
111.05
37.73
50.43
61.29
109.70
109.70
133.06
133.06
4502 - 1
4502
4503 - 1
4503
4504 - 1
4504
4505 - 1
4505
4506 - 1
4506
5.5
7.5
11.0
11.0
11.0
15.0
15.0
18.5
18.5
22.0
11.8
14.3
26.6
26.6
26.6
31.7
31.7
40.5
40.5
44.5
17.53
21.46
29.98
29.98
35.78
45.01
45.01
55.11
55.11
62.48
25.75
31.41
48.46
48.46
54.26
67.02
67.02
83.22
83.22
93.36
33.98
41.37
66.94
66.94
72.74
89.04
89.04
111.33
111.33
124.24
42.20
51.33
85.42
85.42
91.22
111.05
111.05
139.44
139.44
155.12
50.43
61.29
103.90
103.90
109.70
133.06
133.06
167.55
167.55
186.00
20
Hyamat V
Weight of units in kg (approx.)
Hyamat V
Number of stages
07
08
09
02
03
04
05
06
10
11
5/02../.
6/02../.
219
239
229
251
234
257
244
269
249
275
274
305
279
311
279
311
299
335
299
335
13
304
341
15
349
395
5/04../.
6/04../.
219
239
229
251
234
257
239
263
249
275
249
275
279
311
279
311
284
317
299
335
304
341
309
347
5/10../.
6/10../.
259
287
269
299
299
335
319
359
319
359
369
419
374
425
409
467
409
467
2/18../.
3/18../.
4/18../.
5/18../.
6/18../.
292
381
499
598
777
314
414
543
653
843
334
444
583
703
903
383
512
671
845
1069
385
515
675
850
1075
395
530
695
875
1105
397
533
699
880
1111
553
757
991
1240
1544
2/32../.
3/32../.
4/32../.
5/32../.
6/32../.
387
526
714
853
1057
438
597
806
1000
1229
452
618
834
1035
1271
614
851
1138
1410
1722
618
857
1146
1420
1734
702
963
1274
1575
1911
706
969
1282
1585
1923
2/45../.
3/45../.
4/45../.
5/45../.
6/45../.
454
646
833
1095
1297
618
882
1141
1475
1754
700
985
1265
1625
1925
794
1106
1413
1800
2117
872
1223
1569
1995
2351
Movitec 2
60 - 65 dB(A)
51 - 56 dB(A)
Movitec 4
60 - 67 dB(A)
51 - 56 dB(A)
Movitec 10
65 - 69 dB(A)
56 - 61 dB(A)
21
Hyamat V
Dimensions of Hyamat V with Movitec 2, 4 and 10
Control cabinet door
hinged to the left
Acoustic cladding
(supplementary equipment)
Suction side
Discharge
side
5/6
2 and 4
10
770
860
B1
630
735
H1
115
145
1770
1645
L1
DN external thread
Painting:
Baseplate
Control cabinet
22
R2
RAL 5002
RAL 7032
1/
(DN 65)
Hyamat V
Dimensions of Hyamat V with Movitec 18 and 32
see control cabinets
Plan view
Suction
side
Discharge
side
Pump
1085
1085
1085
1085
1238
18/..
1105
1105
1255
1255
1255
32/..
865
865
865
865
953
18/..
885
885
970
970
970
32/..
405
405
405
405
448
18/..
415
415
458
458
458
32/..
460
460
460
460
505
18/..
32/..
470
470
515
515
515
886
1296
1706
2116
2526
L2
820
820
1230
L3
820
1230
820
1230
1230
L4
820
1230
1640
2050
2460
DN
100
100
100
100
150
150
150
DN
H1
18/..
32/..
287
287
287
287
287
18/..
302
302
302
302
302
32/..
Hyamat V
Dimensions of Hyamat V with Movitec 45
see control cabinets
Plan view
Suction
side
Discharge
side
Movitec 45
Number of pumps
1060
1175
1175
1280
1280
B1
840
890
890
940
940
B2
350
375
375
400
400
B3
490
515
515
540
540
L1
886
1296
1706
2116
2526
L2
820
820
1230
L3
820
1230
820
1230
1230
L4
820
1230
1640
2050
2460
DN
100
150
150
200
200
H1
302
302
Flanges drilled to EN 1092-1 PN 16
302
302
302
24
Hyamat V
Control Cabinet Dimensions
1000 x 600 x 250
Hyamat
Rated power
Design
Hyamat
Rated power
Design
V2 - V6
up to 4 kW
Standard
Timer
Volt-free reporting
Operating hours counter
Manual-0-automatic selector
switch
PTC thermistor analysis
Temperature monitoring
Ammeter and voltmeter
V2 - V4
5.5 to 11 kW *)
Standard
Timer
Volt-free reporting
Operating hours counter
Manual-0-automatic selector
switch
PTC thermistor analysis
Temperature monitoring
Ammeter and voltmeter
Full-length cabinet
+
Transfer control unit with terminal strip for all pumps and sensors.
In combination with separately installed control cabinet.
Hyamat
Rated power
Design
V5 - V6
5.5 to 7.5 kW
V2 - V4
15 kW
V2 - V3
18.5 to 22 kW
Standard
Ti
Timer
Volt-free reporting
Operating hours counter
Manual-0-automatic selector
switch
PTC thermistor analysis
Temperature monitoring
Ammeter and voltmeter
25
Hyamat V
Control cabinet consisting of:
Transfer Control Unit and Full-length Cabinet (1800 x 1200 x 400 mm) and 5 m Connection Cable
Transfer control unit
Control cabinet door
hinged on the left
Full-length cabinet
+
Transfer control unit with terminal strip for all pumps and sensors.
In combination with separately installed switchgears and control cabinet.
Hyamat
Rated power
Design
V5 - V6
11 to 15 kW
V4 - V6
18.5 to 22 kW
Standard
Volt-free reporting
Manual-0-automatic selector switch
Operating hours counter
PTC thermistor analysis
Temperature monitoring
Ammeter and voltmeter
26
Hyamat V
27
1953.51-10 / 1.11.2004
Hyamat V