INSTALLATION OF STI-7522 & STI-7523 PROTECTIVE CABINET

INSTALLATION OF STI-7523 ENCLOSURE


1. Insert the (4) mounting tabs fully into backbox mounting tab
slots. Use rubber mallet if necessary.

STI-7523 THUMB LOCK


STI-7522 KEY LOCK AVAILABLE
MAGNET

2. After selecting a suitable location, place enclosure in closed


position, against the wall. Mark and drill (4) 1/4 in. diameter
holes. Insert the (4) 19033 anchors. Close and lock enclosure.

NL
EO
OUSP
ST

NC Y
RGE
EME

STOP

3. Place enclosure in position making sure the (2) switch wires


are not pinched between the wall and enclosure. Drive in the
(4) screws. Enclosure is now secure.

6297520 GASKET
(1) PROVIDED

19033 ANCHOR
(4) PROVIDED

INSTALLATION OF ALARM ASSEMBLY


1. Place the alarm mounting plate on the
top center of enclosure. Select at least
two of the four optional mounting
holes. Mark and drill 3/16 in. holes and
install the 19018 anchors.

06298 MOUNTING TABS


(4) PROVIDED
04874
MOUNTING
PLATE

19013 SCREW
#10 x 1 1/2 in.
(4) PROVIDED
AMS-10S MAGNETIC CONTACT
SWITCH WITH 24 in. WIRE LEADS

2. Fish the magnetic switch wires through


the alarm mounting plate and the siren
backplate (View A). Next, drive the two
alarm mounting screws into the
previous installed anchors.

SCREW #8-32 x 1/2 in.


(4) PROVIDED

3. Install the two magnetic switch wires


following the terminal switch diagram
(View B).

8.875 in.(225mm)

OPTIONAL MOUNTING
HOLES (4)

ALARM MOUNTING PLATE

ROUTE THE 2 SWITCH WIRES


THROUGH THE HOLE AS SHOWN

STOP

EMERGENCY USE ONLY

16.00 in.
(406mm)

10.875 in.
(276mm)

4. Install the alarm cover using the (2)


tamperproof screws and provided tool.

TOP VIEW

* 1/4 Diameter

3.125 in.(79mm)
FRONT VIEW

A
CABINET

19018 ANCHOR (2) PROVIDED


ALARM MOUNTING PLATE
06202 BACKPLATE

WIRE ACCESS HOLE


9 VOLT ALKALINE BATTERY

VIEW A

ALARM COVER

OP Y
ST USE ONL

19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED

STOP

19011 SCREW - TAMPERPROOF


(2) PROVIDED

NC
RGE
EME

19016 TAMPERPROOF TOOL

19032 KEY (2) PROVIDED

Safety Technology International, Inc. 2306 Airport Rd. Waterford, Michigan 48327-1209 800-888-4784 Fax: 248-673-1246 Web: www.sti-usa.com Email: info@sti-usa.com

CIRCUIT BOARD SET-UP


ALARM CIRCUIT BOARD SET-UP
ALARM VOLUME SWITCH
TRIP DELAY SWITCH
ALARM
DURATION
SWITCH

(ON) JP2

TERMINAL BLOCK

(OFF) JP5

(OFF) JP4
(OFF) JP3

(FACTORY DEFAULT SETTINGS)

FROM MAGNETIC
CONTACT SWITCH

NC COM NO GD

V+

KEY SWITCH
TERMINALS

FORM C
DRY
CONTACTS

REMOTE
POWER
INPUT
9-24 VDC

TERMINAL STRIP

JUMPER

(ON) JP7
MAGNETIC CONTACT
REED SWITCH

ARMING SWITCH

RS1

RS2

KEYSW

TERMINAL BLOCK WIRING CONNECTIONS


N

VIEW B

SWITCH SETTINGS
FEATURE

JP2

JP3

JP4

Volume - High (105 dB) at 1 ft.

ON*

Volume - Low (95 dB) at 1 ft.


Duration - 30 Second Alarm

OFF
OFF

OFF

Duration - 180 Second Alarm

OFF

ON

Duration - Continuous Alarm

ON*

OFF*

Duration - Annunciator Mode

ON

ON

Trip - Immediate

JP5

JP7

OFF*

Trip - 15 Second Delay

ON

Arming - Immediate

ON*

Arming - 15 Second Delay

OFF

*Factory Settings
Note: Slide black lever to desired ON/OFF position as labeled on circuit board.

Electronic warranty form at www.sti-usa.com/wc14

Printed in USA

Safety Technology International, Inc.

Safety Technology International (Europe) Ltd.

2306 Airport Road Waterford, Michigan 48327-1209


Phone: 248-673-9898 Toll Free: 800-888-4784
Fax: 248-673-1246 www.sti-usa.com

Unit 49G Pipers Road Park Farm Industrial Estate Redditch


Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only)
E-mail: info@sti-europe.com Web: www.sti-europe.com
Inst. Sht. 7523, JAN2010