ASPIRATING SMOKE DETECTION PRICE LIST


HIGH SENSITIVITY SMOKE DETECTION
Thame Park Road, Thame, Oxfordshire,
OX9 3RT, UK
Tel: +44 (0) 1844 265003
Fax: +44 (0) 1844 265156
www.kfp.co.uk

ISSUE DATE: 1st January 2009


VALID FROM: 1st January 2009
VALID TO: Until Further Notice

All prices are Ex-works and subject to alteration without notice.


Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

PRODUCT

PART NO.

PRICE

HART XL Units
Detector Unit (Standard Sensitivity 0.005 to 1%/m)
Display Module
Intelligent Interface Module With Modem (for use with LaserNet Network)*
Intelligent Interface Module Without Modem (for use with LaserNet Network)*

53836-K183
53836-K182
53836-K191
53836-K190

2,105.00
510.00
1,265.00
1,116.00

* limited stock available

HART XL Accessories
Interface Card (Remote inputs for Silence, Reset, Isolate & 4-20mA Output)
Apollo XP95, Discovery Analogue Addressable Loop Interface Card
DCC to RG Serial Port Programming Lead (9 way)

44782-K165X
44782-K167X
53800-H08
36215-K228

325.26
165.82
19.30
25.00

HART XL CD-ROM (containing HART XL Installation, Operation & Maintenance Manual, LaserNet Software & User Guide)

HART Mini
Detector - Bottom Pipe Entry
Detector - Top Pipe Entry
Detector - Bottom Pipe Entry (networkable version)
Detector - Top Pipe Entry (networkable version)

53836-K205K-00
53836-K205K-01
53836-K205KN-00
53836-K205KN-01

1,610.00
1,610.00
2,054.00
2,054.00

Power Supply Units & Batteries


Self Contained Power Supply Unit with space for two 12v 2.0 Ah batteries
2.5A Power Supply Unit with space for two 12volt 12 Ah Batteries
Battery Box with Space for up to to 18 Ah Batteries
12 volt, 2Ah Battery (For use with 53836-K185)
PS12120 12 volt, 12.0 Ah rechargeable sealed lead acid battery
PS12170 12 volt, 17.0 Ah rechargeable sealed lead acid battery

HSSD Price List 2009

53836-K185
53836-K235-00
43782-K147
23911-K051
23911-H10
23911-H11

Page 1 of 4

438.00
310.00
125.44
47.84
25.52
46.78

ASPIRATING SMOKE DETECTION PRICE LIST


HIGH SENSITIVITY SMOKE DETECTION
Thame Park Road, Thame, Oxfordshire,
OX9 3RT, UK
Tel: +44 (0) 1844 265003
Fax: +44 (0) 1844 265156
www.kfp.co.uk

ISSUE DATE: 1st January 2009


VALID FROM: 1st January 2009
VALID TO: Until Further Notice

All prices are Ex-works and subject to alteration without notice.


Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

Senator 25 , 100 & 200 Detectors


Senator 25 detector including Docking station
Sub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25%
obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no
external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status indicators
provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum
pipework length 50m (25m in high airflow).
Dimensions: 140 x 200 x 85

30671-KID

954.00

Senator 25 detector including Docking Station and relay/ input card


Sub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25%
obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no
external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status indicators
provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum
pipework length 50m (25m in high airflow).
Dimensions: 140 x 200 x 85

30760-KID

1,054.00

30672-KID

1,300.00

Senator 100 detector including Docking Station and relay/ input card
Sub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25%
obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no
external input. Laser Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status indicators
provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum
pipework length 100m (50m in high airflow).
Dimensions: 297 x 200 x 85

30764-KID

1,400.00

Senator 200 Detector


Aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent
on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser
Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status LED's and menu driven LCD
display for indications and programming setup. Relay outputs for interfacing to other fire control equipment. LPCB approved with
a maximum pipework length of 200m although unit is capable of operating with a maximum of 250 metres of sampling pipe.
Requires 24Vdc power supply (pt no. 30826-KID).
Dimensions: 472 x 372 x 95

30621-KID

1,821.00

Senator 200 Detector with Command Module


Aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent
on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser
Dust Discrimination (LDDTM) makes this product suitable for a wide range of environments. Status LED's and large LCD display
for indications and programming setup. Relay outputs for interfacing to other fire control equipment. LPCB approved with a
maximum pipework length of 200m although unit is capable of operating with a maximum of 250 metres of sampling pipe.
Capable of single point programming and setup for entire SenseNET network (Max 127 detectors). Requires 24Vdc power supply
(pt no. 30826-KID)
Dimensions: 472 x 372 x 95

30620-KID

2,689.00

Senator 200 - Steel enclosure


This is the same as unit 30621-KID in a rugged sheet steel enclosure.

30706-KID

1,778.00

Senator 200 with Command Module - Steel enclosure


This is the same as unit 30620-KID in a rugged sheet steel enclosure.

30707-KID

2,645.00

Senator 200 - Minumum Display


This is the same as 30706-KID with LED status indications for 'Normal', 'Fault' and 'Alarm' only. Programmable via RS485 serial
connection port or Command Module.

30710-KID

1,648.00

Senator Ex Explosion Proof smoke detector


ATEX approved aspirating smoke detector EExd IIB + H2 T3, equipment group 2 (zones 1,2 and 3). Group gases A and B +
Hydrogen.
Sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25% obs/m dependent on environment). Classifire 3D
Artificial Intelligence allows it to automatically adjust sensitivity with no external input. Laser Dust Discrimination (LDDTM) makes
this product suitable for a wide range of environments. Status LED's for 'Fire', 'Fault' and 'OK'. Relay outputs for interfacing to
other fire control equipment. Maximum pipework length 50m still air (25m moving air). Requires 24Vdc power supply.
Dimensions: 400 x 200 x 165 inc. Flame arrestors.

30731-KID

6,852.00

Senator Ex Explosion Proof smoke detector - Stainless Steel enclosure


Identical to 30731-KID within a stainless steel enclosure

30732-KID

Price on request

Senator 100 detector including Docking Station


Sub miniature aspirating smoke detector with a sensitivity scale ranging from 'hypersensitive' to 'low' sensitivity (0.002 - 25%
obs/m dependent on environment). Classifire 3D Artificial Intelligence allows it to automatically adjust sensitivity with no
TM
external input. Laser Dust Discrimination (LDD ) makes this product suitable for a wide range of environments. Status indicators
provided for 'OK', 'FIRE' and 'Fault'. Fire and Fault relay outputs for interfacing to other fire control equipment. Maximum
pipework length 100m (50m in high airflow).
Dimensions: 297 x 200 x 85

Hazardous area aspirating smoke detection

HSSD Price List 2009

Page 2 of 4

ASPIRATING SMOKE DETECTION PRICE LIST


HIGH SENSITIVITY SMOKE DETECTION
ISSUE DATE: 1st January 2009
VALID FROM: 1st January 2009
VALID TO: Until Further Notice

Thame Park Road, Thame, Oxfordshire,


OX9 3RT, UK
Tel: +44 (0) 1844 265003
Fax: +44 (0) 1844 265156
www.kfp.co.uk
All prices are Ex-works and subject to alteration without notice.
Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

Command Modules
Stand alone Command Module with internal PSU
Provides single location display, control and interfacing options for up to 127 networked Senator detectors, Integral PSU and
space for 2 x 12v 17Ah SLA standby batteries.
Dimensions: 472 x 372 x 95

30623-KID

1,822.00

Stand alone Command Module without PSU


Provides single location display, control and interfacing options for up to 127 networked Senator detectors. Requires 24Vdc
power supply (pt no. 30826-KID)
Dimensions: 472 x 372 x 95

30624-KID

876.00

Command Module with PSU - Steel enclosure


This is the same as unit 30623-KID in a rugged sheet steel enclosure.

30708-KID

1,265.00

Command Module without PSU - Steel enclosure


This is the same as unit 30624-KID in a rugged sheet steel enclosure.

30709-KID

833.00

19" Rack mount Command Module


Senator Command module housed within a 19" sub assembly for mounting inside standard 19" enclosures. 3U high, complete
with 6 x 20mm cable entries to the rear.
Requires a suitable 24v power supply with battery back-up.

30627-KID

1,300.00

Senator RDU enclosure including Command module


Low profile 150mm deep, 9U high enclosure with a glazed lockable front door containing a Senator Command module and space
for up to 16 RDUs and relay cards.
A suitable 24 power supply with battery back-up is required.

30823-KID

Price on request

Senator RDU enclosure


Low profile 150mm deep, 9U high enclosure with a glazed lockable front door which has space for installing up to 24 RDUs and
relay cards.
A suitable 24 power supply with battery back-up is required.

30824-KID

Price on request

Senator relay / input card


4 staged relay outputs for interfacing to other fire control equipment. Input terminals for Remote reset, Remote isolate and
Remote day/night functions.

30436-KID

100.60

APIC - Apollo card


Apollo protocol addressable interface card allowing the Senator detectors to be connected directly to the loop of an Apollo
protocol control panel.

30430-KID

133.60

PS25 intelligent Power Supply


Intelligent wall mountable 24vdc power supply rated at 1.4 Amp. Finished in a neutral colour with sufficient space for 2 x 12V
17Ah SLA batteries. Approved to EN54-4

30826-KID

208.00

Senator Bus Isolator


Prevents SenseNET network short circuit isolation for unprotected devices

30754-KID

122.00

Interference Suppression ferrite rings (pack of 5)

30711-KID

6.10

Senator Serial Cable


Programming lead for Senator detector units

30419-KID

26.00

Senator Air Heater Box


For use with Senator detectors when the sample points are installed in low temperature applications

30422-KID

512.00

Aspirator with thermostat


for use with Heater Box (Part no. 30422-KID), will monitor the operation of the heater element and provide a contact which can
be monitored by fire alarm control panel

30425-KID

262.00

Wire Burn test rig


Enables testing of aspirating systems to BS6266

30051-KID

347.00

Wire Burn test wire


For use with wire burn test rig (Part no. 30051-KID)

21888-K033

14.00

Smoke Pellets
6 x 13g smoke pellets per tube

21888-K030

8.90

Senator Accessories

SenseNET
SenseNET Remote Display Unit for 19" card frame mounting
Mimics the displays of Senator detectors via the SenseNET bus. 3U high metal front panel allows it to be installed in a 19" rack
enclosure (part no. 30823-KID or 30824-KID), or in a single RDU wall mounting enclosure (part no. 30817-KID)

30802-KID

144.00

SenseNET Remote Display Unit relay board (optional)


Remote relay board for use with the RDU and provides 4 alarm and common fault relays.

30803-KID

31.20

SenseNET Control Unit


interfaces the SenseNET detector unit with PC serial port. Control unit comes complete with connecting cables, power supply unit
and PC software.

30804-KID

1,041.00

SenseNET Contact Monitor


connects to the SenseNET network and allows monitoring of up to 7 clean contacts from other systems.

30805-KID

113.00

HSSD Price List 2009

Page 3 of 4

ASPIRATING SMOKE DETECTION PRICE LIST


HIGH SENSITIVITY SMOKE DETECTION
ISSUE DATE: 1st January 2009
VALID FROM: 1st January 2009
VALID TO: Until Further Notice

Thame Park Road, Thame, Oxfordshire,


OX9 3RT, UK
Tel: +44 (0) 1844 265003
Fax: +44 (0) 1844 265156
www.kfp.co.uk
All prices are Ex-works and subject to alteration without notice.
Kidde Fire Protection Terms and Conditions of Sale apply. Copies on request or from our website www.kfp.co.uk

RDU 19" Sub Frame


19" sub frame with space for mounting up to 8 RDUs.

30814-KID

114.50

In-fill plates for 19" Sub Frame


Brushed aluminium plates for blanking unused slots in 19" sub frame, plates are the same size as RDU.

30812-KID

8.70

In-fill plate with PC port


Brushed aluminium plate for sub 19" frame provides socket for connection of PC. PC interface not included.

30813-KID

43.50

SenseNET software CD and Dongle

30250-KID

780.00

Single RDU wall mounting enclosure (RDU not included)


Dimensions 150 x 80 x 60

30817-KID

83.30

SenseNET (RS485/RS232 CAT5 Converter)


Allows SenseNET data to be sent across a CAT 5 Local Area Network (LAN)

30811-KID

277.60

PC interface (Software & Dongle not included)

30816-KID

260.00

SnifferPipe Aspirating Smoke Detection Pipe & Fittings


Air Sampling Pipe, Red ABS, 25mm diameter (3 metre length)

21888-K016

4.60

90 Degree elbow - 25mm

21888-K017

1.10

45 Degree elbow - 25mm

21888-K018

1.10

Equal Tee - 25mm

21888-K019

2.50

Straight Socket - 25mm

21888-K020

0.52

End Cap - 25mm

21888-K021

0.58

Union Socket - 25mm

21888-K024

3.10

Pipe Clip - 25mm

21888-K025

0.58

3/4" BSP Imperial to 25mm Metric Adaptor (See Note 1)

21888-K022

2.00

1" BSP Imperial to 25/32mm Metric Adaptor (See Note 1)

21888-K023

2.00

Particle Separator

21888- K163

130.00
32.00

Replacement Foam Elements for Particle Separator

21888-K164

Mini Sample Point Assembly c/w 25mm OD Adaptor & 2 metre Capillary Tube

21888-K034

15.00

Flush Sampling Point Assembly c/w 25mm OD adaptor & 2 metre Capillary Tube

21888-K035

15.00

Capiliary Tube (10mm OD, 8mm ID) 30 Metre reel

21888-K062

90.00

Pipe Cutting Tool

21888-K028

36.00

Pipe Warning Label (100 Labels per roll)

39155-H11

9.00

NOTE 1: Inlet Adaptors are supplied with Detection Unit as standard.

HSSD Price List 2009

Page 4 of 4