Вы находитесь на странице: 1из 2

Air/Gas Service Products

Small Flow Cartridges

Sealkleen Emflon II Membrane Cartridges


Specifications
Materials
FDA-listed materials per 21 CFR
Medium: Double layer, hydrophobic PVDF
Support/Drainage Layers: Polypropylene
Core/Cage/End Caps: Polypropylene

Removal Ratings
Air/Gases: <0.01m particulate1
Liquids: 0.2 m, sterilizing 2

Dimensions (nominal)
Lengths:

SLK7001: 2.5 in. (64 mm)


SLK7002: 5.0 in. (127 mm)
Diameter: 2.25 in. (57 mm)
Operating Conditions
Max. Differential Pressure/Temp.: 3
60 psid (4.1 bar) to 140F (60C)
Description

Technical References
See Appendix for titles.
STRPUF-15
PDA/Virus
TR-870b
Housing Cross Reference
Sealkleen Housing
SLK8400 Series

Air/Gas Service Products

Housing Link
SLK 8400

By CNC particle analysis. Also retains 100%


of bacterial and phage/virus aerosols.
2
Lot samples of assemblies retain > 10 7 cfu/cm2
of Brevundimonas diminuta liquid challenge
per mod. ASTM F838-83 and FDA guidelines.
3
In air/N 2 service or other compatible gases.
4
Lab tests to establish multi-cycle resistance.
Filters should be qualified in actual use.
Contact Pall for recommended procedures.
5
60:40 IPA:Water (v:v) wetted.
6
Contact Pall for methods and values.
7
Estimated values based on < 5 mg per 10 in.
(254 mm) length after 1 hr steam at 257F (125C).
8
Per lot sample soak or rinse-up flush aliquots.

Pall Sealkleen Junior style filter cartridges


with double layer Emflon II hydrophobic
polyvinylidene fluoride (PVDF) membranes
provide reliable absolute removal of bacteria and viruses from dry or wet air or gas
streams. The Pall Sealkleen assembly features a patented sanitary clamp sealing
design which eliminates the possibility of
bypass from upstream to downstream.
The assemblys in-line design and ease of
change-out make it convenient for small
to moderate flow sterile tank vent and gas
supply applications.
Double layer hydrophobic
PVDF membranes
High efficiency gas filter
0.2 m sterilizing grade
Bacteria retentive in liquids
0.01m rated in gas flow
Virus retentive in gases
Broad chemical compatibility
Low pressure loss
100% integrity tested
Repeatedly steamable in situ
Individually serialized
Manufactured for use in

conformance with cGMP


ISO 9000 Certified Quality System
Pharmaceutical P optimized
Certificate of Test provided

Copyright 2000 by Pall Corporation. All rights reserved.

Autoclave/Steaming
Cumulative Autoclave Time: 4
105 hrs (1hr cycles) at 250F (121C)
50 hrs (1hr cycles) to 284F (140C)
Steamable in-situ: 4
165 hrs (1hr cycles) to 284F (140C)
Integrity Testing
Forward Flow (air test gas) 5

Size
cc/min at psi (mbar)
SLK7001
1.6 at 12 (830)
SLK7002
3.5 at 12 (830)
Water Intrusion Testable 6
Aqueous Extractables (20C)
<2 mg per cartridge 7

Quality/Bio-Safety
Biological Tests:
Meets USP Biological Reactivity,
In Vivo, for Class VI-121C plastics.
Effluent Quality Tests: 8
Meets Cleanliness per USP
Particulates in Injectables.
Non-Fiber-Releasing per 21 CFR
Non-Pyrogenic per USP
Bacterial Endotoxins (<0.25 EU/ml).
Meets Oxidizables and pH
per USP Purified Water.
Steam Resistance: Lot samples
multi-cycle autoclave challenged.

Air/Gas Service Products


Small Flow Cartridges

For information or to order, call:

1-800-717-7255
or 516-484-5400 Fax: 516-625-3610
pharmafilter @ pall.com
www.pall.com

Pressure Drop vs. Air Flow Rates 9

Air Flow Rate (Nm3/h) at Ambient Temperature


0
20
40
60
80
100

120

7002 (Vent)

200

7001 (50psig)

150

100
1
7002 (100psig)
0

7001 (100psig)
7002 (50psig)

0
60
20
40
Air Flow Rate (scfm) at Ambient Temperature

50
0

Clean Pressure Drop (mbar)

Clean Pressure Drop (psid)

7001 (Vent)

250

Typical initial clean P, air at 68F (20C). For complete assembly pressure
drop, add filter cartridge value to housing value at specified flow rate and inlet
pressure. For gases other than air or nitrogen, contact your local Pall distributor.
Note: Curve labels denote length codes and inlet pressures.

80

Part Numbers / Ordering Information

10

Nominal
Length
5.0 in. (127 mm)
2.5 in. (64 mm)

P in the part number indicates optimized


and qualified for pharmaceutical use including
100% integrity testing and Certificate of Test
provided. V suffix indicates optimized for vent /
air /gas service.
Note: For sizing assistance or scale-up to larger
filters, contact your local Pall distributor.

Filter
Area
2.3 ft 2 (2150 cm 2)
1.2 ft 2 (1100 cm 2)
Specifications and Availability: The information
provided is a guide to the part number structure
and possible options. Product availability may be
subject to change without notice. All specifications
are nominal. This literature was reviewed for accuracy at the time of publication. For current information on the products and test methodologies,
consult your local Pall distributor.

Air/Gas Service Products

Part
Number 10
SLK7002V002PV
SLK7001V002PV

Copyright 2000 by Pall Corporation. All rights reserved.