ROI-S05749-05UE
April, 2010
PASOLINK NEO
6-52 GHz PDH/SDH DIGITAL RADIO SYSTEM
Section II OPERATION
CONTENTS
TITLE
PAGE
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
2.1
2.2
CTRL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.3
MODEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
2.4
2.5
2.6
2.7
2.8
E3 INTFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48
2.9
2.10
2.11
2.12
2.13
2.13.1
2.13.2
2.14
2.15
ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-76
3.1
3.2
3.3
3.4
Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
3.5
3.5.1
CL-1
Submission Prohibited
NEC Internal Use Only
CONTENTS
CL-2
2 pages
ROI-S05749
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
3.5.8
3.5.9
3.6
3.6.1
3.6.2
3.6.3
3.7
3.8
3.9
Submission Prohibited
NEC Internal Use Only
GENERAL
ROI-S05749
1. GENERAL
This section provides instructions for operation of the 6 to 52 GHz PDH/
SDH radio system.
This section describes interface terminals and jacks, controls, indicators,
and test jacks. Use of the LCT is required for local operation, monitoring,
control and setup. For details of system and provisioning setup, refer to
Section IV PASOLINK NEO LCT Operation.
1-1
Submission Prohibited
NEC Internal Use Only
GENERAL
ROI-S05749
INTFC (1)
MDP-150MB-1AA
INDOOR UNIT
INTFC (2)
CTRL
MODEM(2)
0678
DATE 2007-09 (H2930)
(WITH OPTION)
(WITH ODU & OPTION)
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
MADE IN JAPAN
PULL
ALM
PWR
2M IN/OUT-B
2M IN/OUT-A
100M
PORT 1
PORT 2
100M
PROTECT
(Blank)
LCT
NMS
MAINT
MEMORY
IDU
AUX/ALM
NE
PASOLINK NEO
SC IN/OUT
EOW
CALL
MMC
IDU 1+0
*1
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
ALM
2M IN/OUT-B
2M IN/OUT-A
PWR
100M
LCT
NMS
100M
2-WAY
G
MAINT
MEMORY
IDU
AUX/ALM
NE
PORT 2
PASOLINK NEO
PROTECT
PULL
PWR
PORT 1
SC IN/OUT
EOW
CALL
MMC
IDU 1+1
Note: *1:When a 2-WAY label is put on the 16E1 INTFC, the 2-WAY/XC mode is available.
*2
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
ALM
WS
PWR
100M
PORT 1
PORT 2
100M
WS IN/OUT
M.S
LCT
NMS
NE
AUX/ALM
PASOLINK NEO
PROTECT
MAINT
MEMORY
IDU
(Blank)
SC IN/OUT
EOW
CALL
MMC
Note: *2:When a M.S label is put on the LAN/WS INTFC, exclusive Main LAN mode is available.
*3
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
G PULL
ALM
PWR
2M IN/OUT-B
2M IN/OUT-A
100M
PORT 1
PORT 2
PROTECT
(Blank)
LCT
NMS
NE
AUX/ALM
100M
156MB
PASOLINK NEO
MAINT
MEMORY
IDU
SC IN/OUT
EOW
CALL
MMC
Equipped with High Capacity 32E1 Interface with 2 Port LAN Interface (H2990D)
Note:*3:When a 156MB label is put on the 32E1 INTFC, the 156MB mode is available.
.
1-2
Submission Prohibited
NEC Internal Use Only
GENERAL
ROI-S05749
PASOLINK NEO
0678
TRP-6G-1B
OUTDOOR UNIT
SHIFT FREQ 161MHz
(NWA-009024)
(NHG)
TX LOW
SERIAL No.
WEIGHT
123456
/
4kg
NEC Corporation
A
7725MHz
2007-09
0.5A
SUB BAND
TX FREQ
DATE
- 48V
TOKYO JAPAN
MADE IN JAPAN
-48V INPUT
CAUTION
Non-ionizing
radiation
0678
PASOLINK NEO
(NWA-034274)
TRP-7G-5B
OUTDOOR UNIT (NHG2)
SHIFT FREQ 154MHz
SUB BAND A
RX LEV
MON
IFL
FG
TX LOW
SERIAL No.
WEIGHT
123456
/
3kg
NEC Corporation
2008-01
0.5A
DATE
- 48V
TOKYO JAPAN
CAUTION
Non-ionizing
radiation
MADE IN JAPAN
CAUTION
HOT SURFACE
Avoid contact.
PASOLINK Mx
0678
TRP-52G-5A
OUTDOOR UNIT
SHIFT FREQ 661MHz
(H0356B)
TX LOW
SERIAL No. 123456
4kg
WEIGHT
NEC Corporation
SUB BAND
TX FREQ
DATE
- 48V
A
51454MHz
2007-09
0.5A
TOKYO JAPAN
MADE IN JAPAN
-48V INPUT
CAUTION
Non-ionizing
radiation
0678
PASOLINK NEO
(NWA-034278)
TRP-13G-5B
OUTDOOR UNIT (NHG2)
SHIFT FREQ 266MHz
SUB BAND A
TX LOW
SERIAL No. 123456
3kg
WEIGHT
NEC Corporation
DATE
- 48V
TOKYO JAPAN
CAUTION
Non-ionizing
radiation
-48V
IFL
2008-01
0.5A
MADE IN JAPAN
CAUTION
HOT SURFACE
Avoid contact.
1-3
Submission Prohibited
NEC Internal Use Only
GENERAL
ROI-S05749
1-4
4 pages
Submission Prohibited
NEC Internal Use Only
ROI-S05749
OPERATING EQUIPMENT
2. OPERATING EQUIPMENT
The indicators, switches, interface terminals and jacks for wiring with the
associated equipment are described here.
The IDU component modules listed in Table 2-1 are plugged-in from front
of the IDU shelf as shown in Fig. 2-1.
The ODU Equipment Type is shown in Fig. 2-2 and Table 2-2.
Note: Use shielded cables which are connected to the D-Sub/RJ-45
connector to suppress interference from affecting the signal and
to reduce electromagnetic radiation which may interfere with
other signal cables.
Note: Twist power cables (+)/() to suppress inductive interference
signals.
2-1
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
PWR
G
PROTECT
3
LCT
NMS
NE
PASOLINK NEO
MAINT
MEMORY
IDU
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
PWR
G
PROTECT
3
LCT
NMS
NE
AUX/ALM
SC IN/OUT
PASOLINK NEO
MAINT
MEMORY
IDU
EOW
CALL
MMC
7
Fig. 2-1 IDU Composition
Table 2-1 IDU Composition
H2930 MDP-150MB-1AA
No.
Unit/Module Name
H2931
RACK
H2940
MODEM
H2940
MODEM
H3040
DC-DC CONV
H2960
STM-1 INTFC
H2965
LAN/WS INTFC
H3021
GbE INTFC
H2960
STM-1 INTFC
H2965
LAN/WS INTFC
H2980
16E1 INTFC
H2990
32E1 INTFC
H3000
48E1 INTFC
H3010
E3 INTFC
H3020
4P LAN INTFC
H2950
CTRL
Remarks
Expandable
1+0 system
1+1 system
()
()
()
()
()
()
()
()
()
()
()
()
()
()
QPSK/16QAM/32QAM/128QAM *1
2-2
Submission Prohibited
NEC Internal Use Only
ROI-S05749
RX LEV
MON
IFL
FG
-48V
IFL
RX LEV MON
ODU
13-38 GHz ODU (NHG2 Type)
ODU
6-38 GHz (NHG type)/52 GHz (Mx Type)
6-11 GHz ODU (NHG2 Type)
Fig. 2-2 ODU Equipment Type
8 GHz
10 GHz
11 GHz
13 GHz
15 GHz
18 GHz
23 GHz
26 GHz
28 GHz
32 GHz
38 GHz
TRP-( )G-1B
(NHG Type)
(Mx Type)
NWANWANWANWANWANWANWANWANWANWANWANWANWA009024-( ) 009026-( ) 009028-( ) 009030-( ) 009032-( ) 009034-( ) 009036-( ) 009038-( ) 009040-( ) 009042-( ) 009044-( ) 009046-( ) 009048-( )
TRP-( )G-5B
(NHG2 Type)
NWA034276-( )
NWA034277-( )
NWA034278-( )
NWA034279-( )
NWA034280-( )
NWA034281-( )
NWA034282-( )
-----
NWANWA034284-( ) 034285-( )
52 GHz
H0356B
------
2-3
OPERATING EQUIPMENT
6 GHz
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Jack (IDU)
2-4
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2.2 CTRL
CALL
PROTECT
NE
NMS
LCT
PASOLINK NEO
PROTECT
LCT
NMS
NE
AUX/ALM
AUX/ALM
MMC
MAINT
MEMORY
IDU
SC IN/OUT
SC IN/OUT
EOW
CALL
EOW
*
MMC
MAINT(amber)
MEMORY(amber)
IDU(red)
Caution*
PROTECT SW is provided only for the CTRL panel replacement. Set PROTECT SW to OFF position (bottom
side) in normal operation. Equipment may not work properly if the PROTECT SW is set to ON position (Upper
side) by mistake.
Refer to ROI-S05751 MAINTENANCE manual for the CTRL panel replacement.
The CTRL generates various control signals based upon LCT setup data
and gathered operating status in the IDU and from the ODU, has SC,
EOW, LAN, NE, EXT ALM, HK, Cluster ALM signals interface. By
Connecting a PC, manual control, performance monitoring and system
setup can be performed.
AUX/ALM (D-Sub
Female 44 pins)
Input/Output Signal
EOW:
1 CH
Frequency:
Level:
6 dBm
Impedance:
600 ohms
ALM:
Output:
Input:
Photocoupler
Bz 1,2 IN:
EOW:
2-5
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
SC IN/OUT (D-Sub
Female 44 pins)
Input/Output Signal
NE2:
Network Element
Level:
RS-485
DSC (RS-232C):
2 CH
Bit rate:
9600 bps
Level:
RS-232C
DSC (V.11):
2 CH
Bit rate:
64 Kbps
Level:
V.11
Impedance:
100 ohms
NE (RJ-45):
Network Element
Level:
10BASE-T
LCT (USB):
NMS (RJ-45):
PNMS
Level:
10BASE-T
Indicators (CTRL)
LED
MAINT
Indication
Remarks
MEMORY Memory Card (MMC) status. ON: Enable access to Memory Card
OFF: Disable access to Memory Card
Blinks: Accessing Memory Card
IDU
2-6
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Switch (CTRL)
Switch
Operating
CALL
PROTECT
Remarks
Description
CTRL
ALM/AUX IN/OUT
(D-sub Female, 44 Pins)
EOW input 1
EOW output 1
EOW input 2
EOW output 2
Pin 5
Ground
Between
Pins 25 and 11
Open
Closed
Between
Pins 24 and 10
Open
Closed
Between
Pins 23 and 9
Open
Closed
Normal state
Alarm state
:
:
2-7
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
Between
Pins 21 and 7
Open
Closed
Between
Pins 20 and 6
Open
Closed
Open
Closed
Open
Closed
Normal state
Alarm/Event state
2-8
:
:
Pin 30
Buzzer input 1
Pin 31
Call output 1
Pin 32
Buzzer input 2
Pin 33
Call output 2
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
CTRL
SC IN/OUT
(D-sub Female, 44 Pins)
NE2 TXD
Pin 3
Ground
Pin 16
Pins 17, 18
Ground
Ground
NE2 RXD
Pin 32
Ground
2-9
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
LCT
(USB connector type B)
Description
Pin 1
Vbus
Pin 4
Ground
NMS (RJ-45)
NMS TXD
NMS RXD
Pins 4, 5, 7 and 8
Not Connected
NE (RJ-45)
NMS TXD
NMS RXD
Pins 4, 5, 7 and 8
Not Connected
Notes: *1: RL1 (Maintenance) and RL2 (IDU CPU/PS1/PS2
ALM OUTUT) are fixed and can not be changed to
other items. The relay contact is rated at 0.2 A.
*2: These alarm items are assigned at the factory (default
setting) and can be changed by the LCT as shown in
Table 2-3 in Section 1 (Alarms may be selectively
assigned to RL3 to RL6).
*3: Photocoupler interface; resistance of open input
terminal is more than 200 kilo ohms. Closed input
terminal is less than 50 ohms.
*4: V11 interface for the TX clock and frame pulse input/
output depend on co-/contra-directional mode setting
in the LCT provisioning menu.
2-10
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
EOW Connection
When EOW signal is connected between two IDUs, perform wiring as follows.
Terminal Station A
EOW 4W S
EOW 4W R
Buzzer IN
Call OUT
1
2
3
4
1
2
3
4
16
17
18
19
16
17
18
19
30
31
32
33
30
31
32
33
IDU Dir. B
ALM/AUX IN/OUT
(D-Sub, 44 Pins)
EOW
4W S
1
2
3
4
EOW
4W R
16
17
18
19
Buzzer IN
Call OUT
IDU Dir. A
ALM/AUX IN/OUT
(D-Sub, 44 Pins)
EOW
Extension
30
31
32
33
IDU Dir. C
ALM/AUX IN/OUT
(D-Sub, 44 Pins)
2-11
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2.3 MODEM
FG (Frame Ground)
TX (green)
RX (green)
XPIC RESET(amber)
IF IN/OUT
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
XPIC CTRL
XIF OUT
XIF IN
PULL
PWR
PWR
Caution: Do not apply to the equipment a voltage that varies sharply. The equipment
may operate wrongly.
Caution: Do not remove/connect the IF cable with the IDU power ON, Turn the IDU
power OFF before connecting/disconnecting the IF cable, or equipment may
be damaged.
Caution: Do not insert/extract the MODEM with the power ON, turn the IDU power
OFF and remove all cables connected to the MODEM before insert/extract the
MODEM, or MODEM may be damaged.
Caution: The top surface of the IDU shelf above MODEM is hot in operation.
The MODEM provides the QPSK/16QAM/32QAM/128QAM
Modulation/Demodulation for E1/E3 (PDH), 10/100BASE-T(X)/
1000BASE-T (LAN) or STM-1 (SDH) data transmission and following
main functions.
- Forward Error Correction using RS/Interleave
- BER (High BER/Low BER) detection/indication/release for internal
and external
- Reducing ODU output signal distortion using BB Linearizer
- Equalization using Transversal Equalizer
- XPIC ODU synthesizer synchronization control
- Interfered signal from opposite polarization cancellation (XPIC)
- IDU/ODU power supply
- System power on/off
2-12
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
340 MHz
RX Frequency:
140 MHz
Power supply:
48 V
Impedance:
50 ohms
Connecting IF Cable length:
5D-FB: less than 150 m
8D-FB: less than 300 m
FG (Screw):
XIF IN:
XIF OUT:
Frequency:
140 MHz
Impedance:
75 ohms
XPIC CTRL
(D-Sub 15 pins, Serial Port)
2-13
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indicators (MODEM)
LED
PWR
Indication
Remarks
ODU
TX (only 1+1)
RX (only 1+1)
XPIC RESET
Switches (MODEM)
Switch
PWR
2-14
Operating
Remarks
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
SELV
SELV (DC IN)
(Molex M5569-04A1 Connector,
4 Pins)
48 V DC power input
Note: Only 48 V (40.5 to 57 V) is available.
Pins 1 and 3
Ground
Pins 2 and 4
48 V
IF IN/OUT
TNC Jack (Female) *
XPIC CTRL
(D-Sub Female, 15 pins)
XPIC SV TXD
XPIC SV RXD
Pin 3
Ground
XPIC SEL IN
XPIC RESET IN
Pin 11
Ground
Pin 15
Ground
between
IDUs
in
XPIC
2-15
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
ALM
2M IN/OUT-A
2M IN/OUT-A
2M IN/OUT-B
2M IN/OUT-C
2M IN/OUT-B
2M IN/OUT-C
Caution: Do not insert/extract the 48E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 48E1 INTFC before insert/extract the 48E1
INTFC, or 48E1 INTFC may be damaged.
Optional I/O BOARD
Following I/O BOARD can be provided when the D-SUB 37 pins interface is required to the 2M IN/OUT INTFC
instead of MDR interface.
D-Sub 37 pins Connector
6 D-Sub Connectors are provided for 48E1.
2M IN/OUT-A
2M IN/OUT-A
2M IN/OUT-A
2M IN/OUT-B
2M IN/OUT-B
2M IN/OUT-B
CH1 to CH8
CH9 to CH16
Note: One Unit space is necessary to install I/O BOARD above IDU.
The 48E1 INTFC applies for up to 48E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.
2-16
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2M IN/OUT-A/-B/-C
(MDR Connector)
Input/Output Signal:
Up to 48E1 signals
Bit Rate:
Code:
HDB3
Impedance:
ALM
Indication
Remarks
Mounting module
inventory.
is
not
matched
with
2-17
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
48E1 INTFC
2M IN/OUT-A
(CH 1 to CH 16)
(MDR Connector, 68 pins)
2-18
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
2-19
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
48E1 INTFC
2M IN/OUT-B
(CH 17 to CH 32)
(MDR Connector, 68 pins)
2-20
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
2-21
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
48E1 INTFC
2M IN/OUT-C
(CH 33 to CH 48)
(MDR Connector, 68 pins)
2-22
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
2-23
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-A
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)
2-24
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-B
(CH 9 to CH 16)
(D-Sub Connector, 37 pins)
Ground
2-25
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-A
(CH 17 to CH 24)
(D-Sub Connector, 37 pins)
2-26
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-B
(CH 25 to CH 32)
(D-Sub Connector, 37 pins)
Ground
2-27
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-A
(CH33 to CH 40)
(D-Sub Connector, 37 pins)
2-28
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-B
(CH41 to CH 48)
(D-Sub Connector, 37 pins)
Ground
2-29
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2M IN/OUT-B
2M IN/OUT-A
ALM (red)
ALM
2M IN/OUT-B
2M IN/OUT-A
100M
PORT 1
PORT 2
100M
100M(green)
COLLISION/DUPLEX(amber)
LINK(green)
Caution: Do not insert/extract the 32E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 32E1 INTFC before insert/extract the 32E1
INTFC, or 32E1 INTFC may be damaged.
Following I/O BOARD can be provided when the D-SUB 37 pins interface is required to the 2M IN/OUT INTFC
instead of MDR interface.
4 D-Sub Connectors are provided for 32E1.
2M IN/OUT-A
2M IN/OUT-A
2M IN/OUT-B
2M IN/OUT-B
CH1 to CH8
CH9 to CH16
CH17 to CH24
CH25 to CH32
User Interface
Note: One Unit space is necessary to install I/O BOARD above IDU.
The 32E1 INTFC applies for up to 32E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.
2 PORT LAN interface provides optionally to transmit up to 100 (156*)
Mbps LAN with/without E1 signals.
*Note:For High Capacity PDH 32E1(H2990D) interface.
The user interface signals conform to ITU-T/IEEE as listed in the
following tables. For the details, refer to Appendix LAN INTERFACE
(10/100BASE-T(X) Application and setting.
Only when the FPGA ROM Ver 3.01 or later is mounted, the ENH
NODAL Mode is supported.
The LAN transmission with the NEO/a (ENH NODAL) equipment is
come possible by using the ENH NODAL Mode.
2-30
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2M IN/OUT-A/-B
(MDR Connector)
Input/Output Signal:
Up to 32E1 signals
Bit Rate:
Code:
HDB3
Impedance:
PORT1/PORT2
(RJ-45) optional
Input/Output Signal:
Flow control:
Forwarding mode:
Store-and-Forwarding
Note: *1: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.
*2: For High Capacity PDH 32E1(H2990D) interface.
ALM
Indication
Remarks
100M
LINK
COLLISION/
DUPLEX
2-31
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
32E1 INTFC
2M IN/OUT-A
(CH 1 to CH 16)
(MDR Connector, 68 pins)
2-32
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
2-33
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
32E1 INTFC
2M IN/OUT-B
(CH 17 to CH 32)
(MDR Connector, 68 pins)
2-34
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
2-35
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-A
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)
2-36
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-B
(CH 9 to CH 16)
(D-Sub Connector, 37 pins)
Ground
2-37
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-A
(CH 17 to CH 24)
(D-Sub Connector, 37 pins)
2-38
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
8E1 INTFC
2M IN/OUT-B
(CH 25 to CH 32)
(D-Sub Connector, 37 pins)
Ground
2-39
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
PORT1
PORT2
2M IN/OUT-B
ALM (red)
ALM
2M IN/OUT-B
2M IN/OUT-A
100M
PORT 1
PORT 2
100M
100M(green)
COLLISION/DUPLEX(amber)
LINK(green)
2-WAY Label
ALM (red)
PORT1
PORT2
2M IN/OUT-B
2M IN/OUT-A
ALM
2M IN/OUT-B
2M IN/OUT-A
100M
PORT 1
PORT 2
100M
2-WAY
100M(green)
COLLISION/DUPLEX(amber)
LINK(green)
Caution: Do not insert/extract the 16E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 16E1 INTFC before insert/extract the 16E1
INTFC, or 16E1 INTFC may be damaged.
Optional I/O BOARD
Following I/O BOARD provides when the BNC 16E1 interface is required to the 2M IN/OUT INTFC instead of DSub 37 pins.
TRAFFIC IN
TRAFFIC OUT
2M IN/OUT-A
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
CH11
CH12
CH13
CH14
CH15
CH16
User Interface
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
CH11
CH12
CH13
CH14
CH15
CH16
2M IN/OUT-B
IDU Interface
User Interface
Note: One Unit space is necessary to install I/O BOARD above or below IDU and 2 D-Sub/D-Sub
cables also.
The 16E1 INTFC applies for up to 16E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.
2 PORT LAN interface provides optionally to transmit up to 80 Mbps
LAN with/without E1 signals.
The 2-WAY/XC PKG (e/w LAN) type is applicable to transmit E1/LAN
signals in two different directions by using one IDU with two MODEMs
and two ODUs.
2-40
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2M IN/OUT-A/-B
(D-Sub Connector)
Input/Output Signal:
Bit Rate:
Code:
HDB3
Impedance:
PORT1/PORT2
(RJ-45) optional
Input/Output Signal:
Flow control:
Forwarding mode:
Store-and-Forwarding
Note: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.
Indicators (16E1 INTFC)
LED
ALM
Indication
Remarks
100M
LINK
COLLISION/
DUPLEX
2-41
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
16E1 INTFC
2M IN/OUT-A
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)
(I/O BOARD IDU INTFC)
2-42
Ground
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
16E1 INTFC
2M IN/OUT-B
(CH 9 to CH 16)
(D-Sub Connector, 37 pins)
(I/O BOARD IDU INTFC)
Ground
CH 10 data output
CH 9 data output
2-43
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
LAN PORT1/PORT2
(RJ-45, 8 pins)
Pin 1
Pin 2
LAN TD/LAN RD
Pin 3
Pins 4 and 5
Not Connected
Pin 6
LAN RD/LAN TD
Pin 7 and 8
Not Connected
2-44
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
STM-1 OUT
ALM
STM-1 IN
STM-1 OUT
STM-1 OUT
ALM (red)
STM-1 IN
ALM
STM-1 OUT
STM-1 IN
ONLINE
ALM (red)
ONLINE(green)
Caution: Do not insert/extract the STM-1 INTFC with the power ON, turn OFF the PWR
switch on the MODEM and remove all cables connected to the STM-1 INTFC before
insert/extract the STM-1 INTFC, or STM-1 INTFC may be damaged.
The STM-1 INTFC provides STM-1 signal interface with two types, one is
electrical and the other is optical. The module performs,
- Coded Mark Inversion (CMI) to Non Return to Zero (NRZ)
conversion
- Optical to Electrical conversion *
- RSOH termination
- Stuffing control
- Hitless switching (for 1+1 configuration)
- Performance monitoring (conforms to G.826/G.828)
- Automatic Laser Shut Down (ALS)*
- Near End/Far End loopback
Note: *: For the Optical INTFC only.
2-45
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
STM-1 IN/OUT
IEC 169-29 (1.0/2.3)
STM-1 IN/OUT
LC
Input/Output Signal:
Electrical
Type:
G.703
Bit Rate:
155.520 Mbps
Level:
1 Vp-p (nominal)
Code:
CMI
Impedance:
75 ohms unbalanced
Optical
Type:
G.957
Bit Rate:
155.520 Mbps
Level:
Code:
NRZ
Wavelength:
1310 nm
2-46
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indication
Remarks
ONLINE
Mounting module
inventory.
is
not
matched
with
2-47
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2.8 E3 INTFC
E3 CH1 OUT
E3 CH1 IN
WS IN/OUT
E3 CH2 IN
E3 CH2 OUT
ALM (red)
PORT1
PORT2
E3 CH2
E3 CH1
ALM
IN
OUT
IN
WS IN/OUT
OUT
100M
PORT 1
PORT 2
100M
100M(green)
COLLISION/DUPLEX(amber)
LINK(green)
Caution: Do not insert/extract the E3 INTFC with the power ON, turn the IDU power OFF and
remove all cables connected to the E3 INTFC before insert/extract the E3 INTFC, or
E3 INTFC may be damaged.
The E3 INTFC applies for up to two (2) E3 (34.368 Mbps) signals, four (4)
or eight (8) WS (2.048 Mbps) signals and two (2) port LAN (10/
100BASE-T(X)) signals interface. The module performs, BipolarUnipolar/Unipolar-Bipolar conversion, Stuffing/Destuffing, Multiplex/
Demultiplex the radio section frame, Hitless Switching and AIS Detection/
Generation for each E3 and WS (E1) signal. The interface impedance of
the WS can be selected from 75 ohms/unbalanced and 120 ohms/balanced
using LCT.
2 PORT LAN interface provides optionally to transmit up to 16 Mbps
LAN signal using WS (E1)/SC signal band.
The user interface signals conform to ITU-T/IEEE as listed in the
following tables.
User Interface Signals (E3 INTFC)
E3 CH1/CH2 IN/OUT
(IEC 169-29 (1.0/2.3)
Input/Output Signal:
E3 signal
Bit Rate:
Code:
HDB3
Impedance:
75 ohms unbalanced
LAN PORT1/PORT2
(RJ-45) optional
Input/Output Signal:
Flow control:
Forwarding mode:
Store-and-Forwarding
2-48
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
ALM
Indication
Remarks
100M
LINK
COLLISION/
DUPLEX
2-49
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
WS INTFC
WS IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)
Ground
2-50
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
LAN PORT1/PORT2
(RJ-45, 8 pins)
Description
LAN PORT
Pin 1
Pin 2
LAN TD/LAN RD
Pin 3
Pins 4 and 5
Not Connected
Pin 6
LAN RD/LAN TD
Pin 7 and 8
Not Connected
2-51
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
PORT1
PORT2
PORT 1
PORT 2
Type A
PORT 1
Type B
WS IN/OUT
ALM
WS
100M
WS IN/OUT
WS IN/OUT
100M
PORT1
PORT2
ALM
ALM
WS
100M
WS IN/OUT
WS IN/OUT
PORT 2
WS IN/OUT
100M
Type C
M.S
Function
Type
Remarks
Main LAN *1
Sub LAN *2
E1 WS*2
: Unavailable
: Available
*1 :
*2:
The LAN/WS INTFC (optional) provides 2 Port LAN interface (for Type
A/C) and 1 WS (E1) interface. The LAN/WS INTFC provides a function
of WS AIS Detection/Generation. The interface impedance of the WS can
be selected from 75 ohms/unbalanced and 120 ohms/balanced using LCT.
The LAN/WS INTFC is installed into the Sub-INTFC Slot2 (for Type A/
B) or Slot1 (for Type C) in the SDH system configuration. The LAN
interface functions for each type are listed in following table.
2-52
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
WS IN/OUT
(D-Sub Connector)
WS (1 E1) interface.
Input/Output Signal:
Type A/C
in Slot 2
LAN PORT1/PORT2
(RJ-45, 8 pins)
10/100BASE-T(X)
LAN interface Port 1 and Port 2 shared.
RX switching is performed through Hit SW by High BER
ALM.
LAN signal is transmitted via RFCOH.
Selectable 2 Mbps depending to WS (E1) CH is assigned
for LAN.
Selectable 64/128/192/256 kbps or 2 MB depending to
SC (SC1 to SC4)/WS CHs are assigned for LAN.
Type C
in Slot 1
LAN PORT1/PORT2
(RJ-45, 8 pins)
10/100BASE-T(X).
LAN interface Port 1 and Port 2 separated (75/75MB,
100/50 MB, Best Effort selectable).
RX switching is performed through Hitless SW.
LAN signal mapping takes place in the STM-1.
RSOH bytes (E1/F1/DCCr) are available.
RMON is available.
Maximum throughput packet size is 1548 bytes.
Type A/C
Input/Output Signal:
Type A/B/C
Flow control:
Forwarding mode:
Store-and-Forwarding
2-53
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
LAN PORT1/PORT2
(RJ-45, 8 pins)
Description
LAN PORT
Pin 1
Pin 2
LAN TD/LAN RD
Pin 3
Pins 4 and 5
Not Connected
Pin 6
LAN RD/LAN TD
Pin 7 and 8
Not Connected
Ground
2-54
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indication
Remarks
100M
LINK
COLLISION/
DUPLEX
WS
ALM
2-55
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
PORT1
PORT2
ALM
LED(red)
PORT3
PORT4
ALM
2M IN/OUT
100M
PORT 1
PORT 2
100M
100M
PORT 3
PORT4
100M
4P LAN INTFC
P1-P4 Shared
(3) Dir-A
(4) Dir-A
(5) Dir-A
P1 P2 P3 P4
2-56
P1 P2 P3 P4
P1 P2 P3 P4
P1 P2 P3 P4
Enabled
Switching
Disabled
(1) Dir-A
P1-P2 Shared
P3-P4 Shared
(2) Dir-A
P1 P2 P3 P4
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
LAN
PORT1
PORT4 (RJ-45)
to
Input/Output Signal:
Flow control:
Forwarding mode:
Store-and-Forwarding
2M IN/OUT
(D-Sub Connector)
8E1 interface.
Input/Output Signal:
Bit Rate:
Code:
HDB3
Impedance:
Terminal
Description
LAN PORT1/PORT2
(RJ-45, 8 pins)
LAN PORT
Pin 1
Pin 2
LAN TD/LAN RD
Pin 3
Pins 4 and 5
Not Connected
Pin 6
LAN RD/LAN TD
Pin 7 and 8
Not Connected
2-57
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2M IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)
Description
Ground
2-58
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indication
100M
LINK
COLLISION/
DUPLEX
ALM
Remarks
2-59
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
1000BASE-T
Indicator
OPT
ALM
OUT
IN
PORT
The GbE INTFC (optional) provides 1000BASE-SX/LX and 1000BASET interface. The GbE INTFC is installed into the Main-INTFC slot (Slot1)
instead of the STM-1 INTFC in the SDH (128QAM) system
configuration. The signal is connected either SFP (for 1000BASE-SX/LX)
or RJ-45 (for 1000BASE-T).
The LAN signal is transferred to STM-1 signal by data mapping using
unique method to improve throughput. The RSOH bytes (E1/F1/DCCr) is
available between radio links. The RMON for LINE side is available but
DMR side is unavailable. The maximum passage packet size is 9600 bytes.
The GbE INTFC is applicable together with the LAN/WS INTFC.
2-60
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
1000BASE-SX/LX:*
1000BASE-SX:
1000BASE-LX:
1000BASE-SX/LX Input
1000BASE-SX/LX Output
Type:
H3021A: 1000BASE-SX
H3021C: 1000BASE-LX
Flow control:
Link
Forwarding:
Loss
Disabled/Enabled selectable
1000BASE-T:
1000BASE-T Port:
(RJ-45
Interface
Connector)
Flow control:
Link
Forwarding:
Loss
Disabled/Enabled selectable
2-61
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
1000BASE-SX
1000BASE-LX
IN (Right side)
1000BASE-SX/LX Input
1000BASE-SX/LX Output
1000BASE-T
(RJ-45, 8 pins)
1000BASE-T Input/Output
(MDI/MDI-X)
Pin 1
DATA-A+/DATA-B+
Pin 2
DATA-A/DATA-B
Pin 3
DATA-B+/DATA-A+
Pin 4
DATA-C+/DATA-D+
Pin 5
DATA-C/DATA-D
Pin 6
DATA-B/DATA-A+
Pin 7
DATA-D+/DATA-C+
Pin 8
DATA-D/DATA-C
2-62
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indicator
Indication
Remarks
ALM
2-63
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
This module provides 8E1 channels and four ports 10BASE-T/100BASETX interfaces. By using VLAN configuration, one signal capacity can be
share among four LAN ports. LAN throughput maximum bandwidth can
be set from 2 Mbps to 100 Mbps.
When this module is applied, use of SC channel is unavailable.
The LAN Port switching function is selectable as LAN Port Usage
is Shared Mode.
LAN
PORT1
PORT4 (RJ-45)
to
Input/Output Signal:
Flow control:
Forwarding mode:
Store-and-Forwarding
2M IN/OUT
(D-Sub Connector)
8E1 interface.
Input/Output Signal:
Bit Rate:
Code:
HDB3
Impedance:
2-64
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
LAN PORT
Pin 1
Pin 2
LAN TD/LAN RD
Pin 3
Pins 4 and 5
Not Connected
Pin 6
LAN RD/LAN TD
Pin 7 and 8
Not Connected
2-65
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2M IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37
pins)
Description
Ground
2-66
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indication
100M
LINK
COLLISIO
N/
DUPLEX
ALM
Remarks
2-67
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
1000BASE-SX/LX:
1000BASE-SX:*
1000BASE-LX:*
1000BASE-SX/LX Input
1000BASE-SX/LX Output
Type:
H3022B 1000BASE-SX
H3022C 1000BACE-LX
Flow control:
Link Loss
Forwarding:
Disabled/Enabled selectable
* For GbE INTFC-E, this function supports as Link Down Control
1000BASE-T:
1000BASE-T Port:
(RJ-45
Interface
Connector)
Flow control:
Link Loss
Forwarding:
Disabled/Enabled selectable
2-68
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Description
1000BASE-SX
1000BASE-LX
IN (Right side)
1000BASE-SX/LX Input
1000BASE-SX/LX Output
1000BASE-T
(RJ-45, 8 pins)
1000BASE-T Input/Output
(MDI/MDI-X)
Pin 1
DATA-A+/DATA-B+
Pin 2
DATA-A/DATA-B
Pin 3
DATA-B+/DATA-A+
Pin 4
DATA-C+/DATA-D+
Pin 5
DATA-C/DATA-D
Pin 6
DATA-B/DATA-A+
Pin 7
DATA-D+/DATA-C+
Pin 8
DATA-D/DATA-C
2-69
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indicator
Indication
Remarks
ALM
2-70
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
LAN PORT2 to
PORT4 (RJ-45)
All these channels are transmitted over the payload of SDH (STM-1).
Input/Output Signal:
Flow control:
Forwarding mode:
Store-and-Forwarding
WS IN/OUT
(D-Sub Connector)
WS(1xE1) interface.
Input/Output Signal:
2.048 Mbps, HDB3 coded data input/output from/to DTE, 75/120 ohms
(selectable).
Bit Rate:
Code:
HDB3
Impedance:
Terminal
Description
LAN PORT
Pin 1
Pin 2
LAN TD/LAN RD
Pin 3
Pins 4 and 5
Not Connected
Pin 6
LAN RD/LAN TD
Pin 7 and 8
Not Connected
2-71
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2M IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37
pins)
Description
Ground
2-72
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indication
100M
LINK
COLLISION/
DUPLEX
ALM
Remarks
2-73
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
2.14
ROI-S05749
DC-DC CONV
43V
STD
FG(Frame Ground)
ALM
43V
PWR
G
OUT
ALM
OUT
FUSE (250V/8AH)
SELV
PWR LED(green)
FUSE (250V/8AH)
PULL
PWR
PWR
SELV
Note: If the PWR LED is not lit though the PWR switch has set to ON, set the PWR switch to
OFF, remove two fuses from the module and check the conduction of them.
Caution: Do not apply to the equipment a voltage that varies sharply. The equipment may
operate wrongly.
Caution: Do not remove/connect the power supply cable with the PWR switch ON, Turn the
PWR switch OFF before connecting/disconnecting the power supply cable IN or
OUT, if not, module may be damaged.
The DC-DC CONV (optional) converts 20 to 60 V or 20 to 60 V DC
input to 43 V stable DC voltage. The module applies when the
PASOLINK+ ODU is connected to the IDU NEO.
Interface Signals (DC-DC CONV)
SELV
(Molex M5569-04A1, 4 pins) (DC IN)
Input Voltage:
20 to 60 V/+20 to +60 V DC
43V OUT
(Molex M5569-02A1, 2 pins) (DC OUT)
Output:
FG (Screw):
43 V/1.3A
Frame Ground terminal
(5 mm square cable (more than 2.5 mm diameter cable)
(AWG#10) is recommended to apply for the frame
ground. The proper press fix terminal tool shall be
used.)
ALM:
2-74
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
Indication
PWR
Remarks
Operating
PWR
Remarks
Description
SELV
SELV (DC IN)
(Molex M5569-04A1 Connector,
4 Pins)
Pins 1 and 3
Pins 2 and 4
20 to 60 V/(or 0 V)
43V OUT
(Molex M5569-02A1,
2 pins) (DC OUT)
Pin 1
Ground
Pin 2
43 V
Power supply ALM signal output
ALM
(D-Sub Female, 9 pins)
Pins 6 (COM), 1 (NC) and
2 (NO)
Pin 9
Ground
Pins3,4,5,7,8
No connected
Between
Pins 6 and 2
Open
Closed
2-75
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
2.15 ODU
RF IN/OUT
RX LEV
MON
IFL
FG
(Front View)
(Rear View)
FG (Frame Ground)
RX LEV MON
RF IN/OUT
RF IN/OUT
(Rear View)
(Rear View)
6-38 GHz ODU NHG/6-11 GHz ODU NHG2/52 GHz ODU Mx Type
2-76
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
RF IN/OUT
-48V
IFL
RX LEV MON
(Rear View)
(Front View)
RX LEV MON
FG (Frame Ground)
(Bottom View)
The ODU receives 340 MHz IF signal from the IDU and converts it to an
RF signal using a local signal generated by a synthesized local oscillator.
This RF signal is then sent to the antenna through the BPF which limits the
RF transmit signal dispersion. The TX output level is controlled to the
specified from the IDU corresponded to the QPSK/16QAM/32QAM or
128QAM modulation.
The RF signal received from the antenna is amplified to the required level.
Afterward the signal is converted into the 140 MHz IF signal by mixing
with a local signal generated by a synthesized local oscillator. Then the
140 MHz IF signal is sent to the IDU through the IF cable.
2-77
Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT
ROI-S05749
IFL (N Female)
TX Frequency
340 MHz
RX Frequency:
140 MHz
Power supply:
48 V
Impedance:
50 ohms
Connecting IF Cable length:
5D-FB: less than 150 m
8D-FB: less than 300 m
FG (Screw)
RF IN/OUT
RX LEV MON:
Operating
Remarks
2-78
78 pages
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3. SYSTEM SETUP
This section provides system setup to make up proper system
configuration. The setup is performed accessing to the LCT program using
the PC. For the detail procedure, refer to Section IV Appendix LCT
Operation Manual.
Redundancy Setting
INTFC
Modulation Scheme
Transmission Capacity
TX RF Frequency(No.1) [MHz]
TX RF Frequency(No.2) [MHz]
RX RF Frequency(No.1) [MHz]
RX RF Frequency(No.2) [MHz]
Frame ID(No.1)
Frame ID(No.2)
PDH E1
PDH E1 with LAN
PDH E1 with LAN 156MB (*1)
PDH E3 with LAN
PDH 4PORT LAN with E1
1+0(TERM)
1+1(Hot Standby TERM)
1+1(Twinpath TERM)
16E1 Standard PKG(E/W LAN)
32E1 Standard PKG(E/W LAN)
48E1 PKG
E3 PKG(E/W LAN)
4PORT LAN with E1
4PORT LAN with E1(VLAN)
QPSK
16QAM
32QAM
128QAM (*1)
10MB
20MB
40MB
80MB
100MB
156MB (*1)
(Up to #32)
(Up to #32)
3-1
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
MTPC
ATPC
MTPC
ATPC
Not Used
P1-2 Shared/1Port Only(Main)
P1-2 Separated(Main)
P1=100MB/P2=56MB(*1)
P1-2 Shared/1Port Only(SC)
P1-2 Shared/1Port Only(WS)
P1-4 Shared (Main)
P1-2 Shared/P3-4 Shared (Main)
P1-4 Separated (Main)
P1-4 VLAN
100 (156)(*1) Mbps
Note:
3-2
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
TX RF Frequency(DIR-A) [MHz]
TX RF Frequency(DIR-B) [MHz]
RX RF Frequency(DIR-A) [MHz]
RX RF Frequency(DIR-B) [MHz]
Frame ID(DIR-A)
Frame ID(DIR-B)
TX Power Control(DIR-A)
TX Power Control(DIR-B)
LAN Port Usage
(Up to #32)
(Up to #32)
MTPC
ATPC
MTPC
ATPC
Not Used
P1-2 Shared/1Port Only (DIR-A:Main)
P1-2 Shared/1Port Only (DIR-A:SC)
P1-2 Shared/1Port Only (DIR-B:Main)
P1-2 Shared/1Port Only (DIR-B:SC)
P1-2 Star (DIR-A:Main, DIR-B:Main)
P1-2 Star (DIR-A:Main, DIR-B:SC)
P1-2 Star (DIR-A:SC, DIR-B:Main)
P1-2 Star (DIR-A:SC, DIR-B:SC)
P1-2 Mixed (DIR-A:Main, DIR-B:Main)
P1-2 Mixed (DIR-A:Main, DIR-B:SC)
P1-2 Mixed (DIR-A:SC, DIR-B:Main)
P1-2 Mixed (DIR-A:SC, DIR-B:SC)
256 Kbps
80 Mbps
256 Kbps
80 Mbps
3-3
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Note: For the details of setup item of the LAN PORT USAGE,
refer to the LAN INTERFACE (10/100BASE-T(X)) and 2WAY/Cross-connect Application and Setting in Section IV.
3-4
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Redundancy Setting
XPIC Usage
APS Function
Modulation Scheme
Transmission Capacity
TX RF Frequency(No.1) [MHz]
TX RF Frequency(No.2) [MHz]
RX RF Frequency(No.1) [MHz]
RX RF Frequency(No.2) [MHz]
Frame ID(No.1)
Frame ID(No.2)
TX Power Control
LAN Port Usage (Main)
LAN Capacity(Main)
LAN Port Usage (Main)
LAN Capacity(Main)
LAN Port Usage (Main)
LAN Capacity(Main)
LAN Port Usage (SUB)
LAN Capacity(SUB)
SDH STM-1
SDH GbE
2Port LAN
1+0(TERM)
1+1(Hot Standby TERM)
1+1(Twinpath TERM)
STM-1(Optical)
STM-1(Electrical)
SDH GbE
2Port LAN
SDH GbE (VLAN)
Not Used
STM-1 (Optical)
WS
WS/LAN
Not Used
Used (Main Master)
Used (SUB Master)
Unavailable
Available
128QAM
156MB
(Up to #32)
(Up to #32)
MTPC
ATPC
USED
150Mbps
P1=75MB/P2=75MB
P1=100MB/P2=50MB
Best Effort
P1=100MB/P2=Not Used
150Mbps
Port Shared
Stack Master(Port Shared)
Stack Slave
150Mbps
(fixed)
(fixed)
3-5
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-6
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Port 1
Port 2
Port 3
Port 4
LAN port control
Switching Function
2M Framing
Disabled
Enabled
Unframed
PCM31 (FAS+CRC)
PCM31(FAS)
PCM30C(MFAS+CRC)
PCM30(MFAS)
Port Usage
Not Used
Used
Speed & Duplex
AUTONEG (Auto-MDI/MDI-X)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Flow Control
Off
On
Collision Report
Not Report
Report
Link Loss Forwarding
Disabled
Enabled
Port Usage
Not Used
Used
Speed & Duplex
AUTONEG (Auto-MDI/MDI-X)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Flow Control
Off
On
Collision Report
Not Report
Report
Link Loss Forwarding
Disabled
Enabled
For 4P LAN INTFC (same as above Port 1/Port2)
For 4P LAN INTFC (same as above Port 1/Port2)
Main Link Down Control
Disabled
Enabled
MAC Address Learning
Off
On
3-7
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
XC Setting *1
TX Power Control
Relay Setting
3-8
E1 Channel Setting
E3 Channel Setting
Wayside Channel Setting
CH Usage Error Report
AIS Activation Condition
AIS Generated Report
AIS Received Report
E1 Port Impedance (CH1)
E1 Port Impedance (CH2)
E1 Port Impedance (CH3)
E1 Port Impedance (CH4)
E1 Port Impedance (CH5-8)
E1 Port Impedance (CH9-16)
E1 Port Impedance (CH17-24)
E1 Port Impedance (CH25-32)
E1 Port Impedance (CH33-40)
E1 Port Impedance (CH41-48)
Cross Connect Function (XC) *2
DIR-A to DIR-B Connect Setting
DIR-A to Tributary Connect Setting
DIR-B to DIR-A Connect Setting
DIR-B to Tributary Connect Setting
Tributary to DIR-A Connect Setting
Tributary to DIR-B Connect Setting
Tributary to Tributary Connect Setting
DIR-A to DIR-B ALL Connect Setting
DIR-A to Tributary ALL Connect Setting
High BER Threshold
Low BER Threshold
RS-232C-1/2
V11-1/2
V-11-1/2 Direction Setting
ATPC Threshold Level(No.1/2) [dBm]
Additional ATT(No.1/2) [dB]
ATPC Range(MAX)(No.1/2) [dB]
ATPC Range(MIN)(No.1/2) [dB]
ATPC Power Mode
COMM ALM Mode
MTPC TX Power (No.1/2) [dBm]
ATPC Threshold Level(No.1/2) [dBm]
Additional ATT (No.1/2) [dBm]
COMM ALM Mode
TX SW Priority *6
TX SW Lock in Usage*6
TX SW Reverse Function Usage*6
TX SW Sensitivity*6
RX SW Priority *6
RX SW Maintenance Mode
RX SW Condition-Early Warning
ALM output for RL1 to RL6
HK output for RL3 to RL6
Cluster1 to Cluster4 input
Cluster1 to Cluster4 output
Not Used
Used
Not Used
Used
Not Used
Used
Not Report Report
LOF+ High BER LOF
Not Report Report
Not Report Report
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
Enabled
Disabled
*3
*2, *3
*3
*3
*2, *3
*3
*2, *3
*3
*2, *3
1E-3 1E-4 1E-5
1E-6 1E-7 1E-8 1E-9
Not Used SC1 SC2 SC3 SC4
Not Used SC1 SC2 SC3 SC4
Co-directional
Contra-directional
Hold
Mute
Max
Hold
Min
*5
Mute
Hold
*5
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
TCN Threshold(1day)
PMON Select
Others
VLAN/QoS
(for 4P LAN INTFC-E)
OFS
UAS
ES
SES
BBE
SEP
OFS
UAS
ES
SES
BBE
SEP
RX Level TCN Threshold (dBm)
RX Level TCN Threshold(No.2) (dBm)
SES Activation Condition
EOW2 External Setting
Alarm Correlation Capacity
VLAN Mode
QoS Mode
30 (%)
15 (%)
Normal
Invert
Off
On
Port VLAN
Tag VLAN
Port VLAN + Tag VLAN
Double Tag VLAN
Disable
802.1Q User Priority
ToS User Priority
DSCP User Priority
Disable
3-9
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
SUB INTFC
SC Assignment
3-10
V11-1/2
Co-directional
Disable
Contra-directional
Enable
SFP
RJ-45
AUTONEG (1000MB Full Duplex)
Off
On
Disabled
Enabled
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Flow Control
Collision Report
Port2
Port Usage
Speed & Duplex
Flow Control
Collision Report
Link Loss Forwarding
INTFC (Main) Setting
Switching Function
Port1
Port Usage
Speed & Duplex
Flow Control
Collision Report
Link Loss Forwarding
Not Used
Used
AUTONEG (Auto-MDI/MDX)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report Report
Not Used
Used
AUTONEG (Auto-MDI/MDX)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report Report
Disabled
Enabled
Disabled
Enabled
Not Used
Used
AUTONEG (1000M-Full)
AUTONEG (Auto-MDI/MDX)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report Report
Disabled
Enabled
3-11
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Flow Control
Collision Report
Link Loss Forwarding
Port 3
same as above Port2
Port 4
same as above Port2
LAN port control
Main Link Down Control
STM-1 Setting
ALS
TX Power Control
3-12
Not Used
Used
AUTONEG (Auto-MDI/MDI-X)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report
Report
Disabled
Enabled
Disabled,
Radio Only
Radio + LLF(Any Port)
Radio + LLF(ALL Port)
Off
On
Disabled
Enabled
Disabled
Enabled
60sec 180sec 300sec
HOLD
Mute
Max MIN
Hold *5
Mute
Hold *5
Non-Priority Priority No.1
Not Used Used
Not Used Used
Normal
High
Non-Priority Priority No.1
Manual Forced
Included EW Excluded EW
Manual
Forced
Priority High Priority Low
Included SD Excluded SD
Not Used
Used
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
TCN Threshold(15min)
TCN Threshold(1day)
DMR/OCR/RCVR
MUX OCR/RCVR
PMON Select
Others
VLAN/QoS
(for GbE INTFC-E)
QoS Mode
Out
HK
Disabled
Out
OFS
UAS
ES
SES
BBE
SEP
OFS
UAS
ES
SES
BBE
SEP
Enabled
30[%]
15[%]
Normal
Invert
Off
On
Port VLAN
Tag VLAN
Port VLAN + Tag VLAN
Double Tag VLAN
Disable
802.1Q User Priority
ToS User Priority
DSCP User Priority
Disable
3-13
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-14
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
: only E3 interface
*1
*1 : in respective E1 CH
*1
*1
*2
*2 : for LAN transmission
*2
*2
: only 1+1 configuration
UAE
UAE
TCN 15min 1day
Total-15min
Total -1day
TCN-RX LEV
TCN-RX LEV-15min
TCN-RX LEV-1day
PMON(History)
RX Level
RX Level(15min)
RX Level(1day)
Total
Status
OFS
SEP
BBE
ES
SES
UAS
RMON(Line)(15min)
3-15
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Normal
Normal
Normal
Normal
AIS Received
Normal
Normal
Normal
Normal
AIS Generated
Normal
Normal
Normal
Normal
Usage Error
Normal
Normal
Normal
Normal
3-16
Link
Link
Link
Link
Collision
Normal
Normal
Normal
Normal
LLF
Under Execution
Normal
Normal
Normal
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
MODEM
Unequipped
Type Mismatch
Module
LOF
Route ID
High BER
Low BER
Early Warning
MOD
DEM
Input Voltage
Power Supply
IF Cable Short
Linearizer Status
Linearizer
Cable EQL
XIF
XPIC Status
XREF
ATPC Power Mode
CTRL
CTRL Module
MMC Mount
APS SW Fail
APS Online Status
APS Lock in Status
XCTRL
XCTRL Mode Mismatch
3-17
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
INTFC (Sub)
Unequipped
Type Mismatch
LOS (MUX)
E-BER (MUX)
E-BER (DMR)
SD (MUX)
SD (DMR)
Output Control
In-Phase
LOS (DMR)
LOF (MUX)
LOF (DMR)
TF
Unequipped
3-18
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
*1
*1 When LAN Port
*1
*1
Only WS applies
TCN-RX LEV
TCN-RX LEV-15min
TCN-RX LEV-1day
TCN 15min 1 day
MUX-15min
MUX-1day
DMR-15min
DMR-1day
MUX-15min (P)
MUX-1day(P)
DMR-15min(P)
DMR-1day(P)
3-19
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
DMR (W)
DMR (W)
MUX (W)
MUX (W)
RX Level(15min)
RX Level(1day)
(1day)
Status
OFS
SEP
BBE
ES
SES
UAS
(15min)
Status
OFS
SEP
BBE
ES
SES
UAS
(day)
Status
OFS
SEP
BBE
ES
SES
UAS
(15min)
Status
OFS
SEP
BBE
ES
SES
RMON(Line)(15min)
3-20
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Link
Link
Collision
Normal
Normal
LLF
Normal
Normal
Reading
RX Pkts 1024-1518
RX Pkts 1519-MAX
3-21
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3.4 Control
The control condition is based upon equipment setup and provisioning
setup, therefore control items vary depending on the those setup.
The control items that are displayed on the LCT PC are listed in the
following table. the control operation can be performed in Maintenance
ON.
*1
*1
*1
*1
*1
*1
*2
only for E3 Interface
*1
*1
3-22
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
*1
*1
*1
*1
*1
: Only APS configuration
: Only APS configuration
*1
: Only APS configuration
: Only APS configuration
: Only Optical INTFC
: Only XPIC configuration
: Only XPIC configuration
: Only XPIC configuration
: Only XPIC configuration
*1
*1
3-23
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-24
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
TX1
CTRL
OPT INTFC
RX2
O/E
RLOS
TX2
550 50 ms
TIMER
CLEAR
9010S
TX ON
TIMER
20.25S
TX ON
TIMER
ALS CONT
ENABLE/DISABLE
60/180/
300 sec.
DELAY
CONT
RX1
2S
TX ON
TIMER
O/E
SB/DATA
BUS
DATA BUS
LCT or PNMT
3-25
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
SW CTRL
LOS/LOF/BER
DET
OPT IN
Working
STM-1 (OPT)
INTFC
only 1+1
SW
MODEM
OPT OUT
Remote
CTRL
SW CTRL
SW
Protection
OPT IN
OPT OUT
STM-1 (OPT)
INTFC
MODEM
LOS/LOF/BER
DET
Module Failure
The STM-1 (OPT) INTFC monitors the OPT line input signal
interface condition and when an alarm condition occurs in the optical
cable or optical interface module, APS is activated. Also the APS is
activated when remote control signal is received.
Uni-directional APS is performed only in the receiving section of the
local side when a failure or signal degradation of the received signal
is detected in one direction. Fig. 3-3 shows APS switching mode.
3-26
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
SW CTRL
PASOLINK NEO
ASSOCIATED EQUIPMENT
Received OPT failure
(Work)
WORKING
WORKING
(Prot)
PROTECTION
PROTECTION
(1)
WORKING
WORKING
(Work)
(2)
PROTECTION
PROTECTION
(Prot)
SW CTRL
ASSOCIATED EQUIPMENT
(Work)
(1)
WORKING
WORKING
PASOLINK NEO
(Prot)
PROTECTION
PROTECTION
(Work)
WORKING
WORKING
(Prot)
PROTECTION
PROTECTION
(2)
ON LINE
OFF LINE
3-27
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-28
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
LCT MENU
Alarm/Status
Equipment Setup
Inventory
AUX I/O
Maintenance
Provisioning
BER Threshold Setting
SC Assignment
STM-1 Setting
TX Power Control
Condition for TX/RX SW
Condition for APS
Relay Setting
TCN Threshold (15min)
TCN Threshold (1day)
PMON Select
Others
Metering
PMON(Current)
PMON(History)
Manual
APS Condition-SF(PROT)
Priority High
APS Condition-SD(B1)
Included SD
Lock in Usage
Not Used
Range
4
10
24
Forced
Priority Low
Excluded SD
Used
1 to 255
1 to 60
1 to 48
3-29
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
APS Condition-SD(B1)
This is a setup that it includes the SD or excludes SD for the
switchover control condition. When including it, the switchover is
performed when SD reaches the threshold value which is set in BER
Threshold/SD (MUX) in provisioning.
Include SD: Including SD for switchover condition
Exclude SD:Excluding SD for switchover condition
Lock in
The function is used to pause the switchover activation for a period of
time when in the switchover of frequent occurrence.
The following setting is needed to be used for it.
Lock in Count:
Setup for the Lock in threshold value of the
switchover number of times.
(setting range: 1 to 255 times)
Lock in Detect time: Setup for the watching interval of counting
number of times for Lock in.
(setting range: 1 to 60 minutes)
Lock in Hold time: Setup for the duration of pause of switchover
in the Lock in condition.
(setting range: 1 to 48 hours)
The Lock in status can be observed on the Alarm/Status of LCT
display.
The Lock in condition may be released after passing the Lock in Hold
time or the change of setting.
The following is an example in default value.
Lock in Count: 4
Lock in Detect time: 10
Lock in Hold time: 24
This sets into the Lock in condition when the switchover is activated
more than 4 times within 10 minutes interval of watching number of
times. The switchover activation pauses during 24 hours after set in
the Lock in condition. The Lock in condition will be released after
passing of 48 hours and it sets into normal mode.
When it will be manually released that under the Lock in condition,
perform resetting by changing parameter value or changing the
setting condition to Lock in Usage Not Used.
3-30
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-31
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
TRANSMITTING STATION
MODEM
RECEIVING STATION
TX
RX IN LEV
POWER CONT
REMOTE
MODEM
RX
CTRL
CTRL
REMOTE
ATPC CTRL
ATPC CTRL
MODEM
RX
TX
MODEM
3-32
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
-50 dBm
5 dB
(ATPC
HYSTERESIS)
RX LEVEL
-55 dBm
(RX THRESHOLD
LEVEL)
3-33
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Using MTPC-ATPC
The ATPC Control System of the PASOLINK transmits the information on
the receiving level to the opposite station and controls the transmission
level of its local station in accordance with the receiving level of the
opposite station. Transmission level control can be used not only for
setting the same operation (ATPC-ATPC) between local station and
opposite station but also for operation in combination of stations with
different operations (MTPC-ATPC, ATPC-MTPC). The station set in
MTPC mode is not controlled by the information from opposite station but
is fixed in its transmitting output level.
Even if the station is set in the MTPC mode, the opposite station is likely
to be set in the ATPC mode. Therefore, setting the RX Threshold (ATPC
Threshold level) is required for controlling the transmission level of the
opposite station. Between the stations that are respectively set in the
MTPC mode, however, the setting is disabled.
The following is an example of operation between stations set in MTPCATPC mode.
STATION A
PASOLINK
ODU
MTPC
(RX Threshold: 50 dBm)
STATION B
PASOLINK
ODU
ATPC
3-34
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
(MTPC)
MASTER
STATION
(ATPC)
SUBSTATION 1
(ATPC)
SUBSTATION 2
(B)
(A)
(C)
(ATPC)
SUBSTATION 5
(ATPC)
SUBSTATION 3
(ATPC)
SUBSTATION 4
: Diffraction to other route.
(A),(B)
(C) : RX received level down.
3-35
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
OWN STATION
ODU
IDU
STM-1/E1/E3
CODE
DATA
CONV
IN
MUX
MOD
TX
(a)
STM-1/E1/E3
CODE
DATA
CONV
OUT
DEMUX
LCT/
PNMT
CTRL
DEM
RX
DEM
RX
STM-1/E1/E3
DATA
OUT
(b)
TX
MOD
MODEM
MUX
( )INTFC
3-36
CODE
CONV
DEMUX
(c)
MODEM
( )INTFC
IDU
ODU
CODE
CONV
STM-1/E1/E3
DATA
IN
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3.5.5 Link Loss Forwarding Control (LAN and Link Down for VLAN)
Link Loss Forwarding (LLF) control provides two kinds of functions for
10/100BASE-T interface. One is to automatically stop the output from the
LAN port to alert the equipment connected with the LAN port when the
system has been disconnected by the fault in the radio section. The other is
to transmit the information for cutting the link interconnected with the
LAN port in the opposite station when the link between the LAN port and
equipment is faulty. This function can be selected by setting
Provisioning on LCT to Enable or Disable.
AUTO: Output Stop
Radio Fault
FAULT
HUB
LAN
LAN
HUB
PASOLINK NEO
MUX
DATA
IN
PASOLINK
PASOLINK
DATA
OUT
MUX
RADIO SECTION
3-37
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
STATION B
PASOLINK NEO
STM-1
INPUT
STM-1
INTFC
INPUT
LOSS
MODEM
RFCOH
MUX
PASOLINK NEO
MODEM
ODU
ODU
FSYNC
STM-1
OUTPUT
STM-1
LOF
LOF
LOS
LOF
STM-1
INTFC
RFCOH
DEMUX
RFCOH
RLOS/RLOF
Station A
Station B
LCT
Event
STM-1
OUTPUT
LED
LCT
LED
STM-1 Output
Control
IDU ALM
MAIN INTFC
LOS
Under Execution
Shutdown *
(or all 1)
STM-1 Loss of
Frame at Station A
IDU ALM
MAIN INTFC
LOF
Under Execution
Shutdown *
(or all 1)
RX Level Down
N/A
Shutdown *
(or all 1)
Loss of Radio
Frame at Station B
N/A
IDU ALM
Under Execution
Shutdown *
(or all 1)
BER Degrade
(1E-4) at Station B
N/A
IDU ALM
Normal
N/A
3-38
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Control
OPPOSITE STATION
LOCAL STATION
Main Master CH
ODU
IDU
XIF
STM-1-2
IDU
coincidence
V-pol
Dual Pol.
f1
f2
f1
f2
OMT
ODU
H-pol
coincidence
Note:
V-pol
ODU
IDU
STM-1-1
Local/Remote XPIC
reset V-pol
XIF
OMT
REMOTE
Local/Remote XPIC
reset H-pol
H-pol
ODU
IDU
STM-1-2
Sub Master CH
3-39
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
PASOLINK
NEO
PASOLINK
NEO
NMS (LAN)
Connector
PNMS
LCT
Connector
PNMT
PNMS : PASOLINK Network Management System
PNMT : PASOLINK Network Management Terminal
Fig. 3-7 Network Management System
*including VLAN
3-40
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
Capacity
and
Redundancy
Bit Rate
LAN Interface
XPIC
Functionary
1+0 System
1+1 System
Fixed
Available
Available
1. 10 MB
1. 10 MB
Free
Unavailable
Unavailable
2. 20 MB
2. 20 MB
3. 40 MB
3. 40 MB
4. 80 MB
4. 80 MB
5. 100 MB
5. 100 MB
6. 156 MB
6. 156 MB
16E1 + 2P LAN
(2-WAY/XC) *1
40MB 80MB
40MB 80MB
E3
Interface
Cards
1+1
32E1 + 2P LAN
10MB 20MB 40MB 80MB 100MB 10MB 20MB 40MB 80MB 100MB PDH
48E1
10MB 20MB 40MB 80MB 100MB 10MB 20MB 40MB 80MB 100MB
4E1 + 4P LAN*
10MB 20MB 40MB 80MB 100MB 10MB 20MB 40MB 80MB 100MB
STM-1 Ele
156MB
156MB
156MB
156MB
156MB
156MB
2P LAN
156MB
156MB
GbE*
156MB
156MB
SDH
3-41
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-42
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-43
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-44
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
(b) RX Switch
RX switching in 1+1 Twin-path/HS system is performed by the HL
SW on the ( ) INTFC module.
Two types of RX switch controls are provided: automatic
switching that is initiated by the quality deterioration of the
received signal and manual switching that is initiated by the
operator using the LCT.
The switching mode and switching priority for automatic and
manual switching are identical to those of TX switching. However,
the switching priority is only valid under automatic switching
control. This is because automatic switching is implemented by
hardware logic and manual switching is implemented by software
logic. That is, automatic switching and manual switching are
completely independent and separate operations. Thus, when the
operator reverts to automatic switching after performing manual
switching, the channel will be re-selected by the switch control
logic circuit.
Switching Mode:
1. Manual: Applied in Maintenance mode.
2. Auto: Normal operating mode.
RX SW Setup in provisioning has following features:
Switching Priority:
1. Non Priority: Selecting non revertive mode.
2. Priority No.1: This mode is applied to select No.1
when both No.1 and No.2 are normally operating.
RX SW Maintenance Mode:
1. Manual mode, this disables the RX SW manual control
when either No. 1 or No. 2 RX route is in alarm status.
2. Forced mode, this enables the RX SW manual control
though either or both No. 1 and No. 2 RX routes are in alarm
status.
Caution: When the RX SW mode is set to Forced in
provisioning, RX SW manual control can select either
No. 1 or No. 2 RX route though one is alarmed. Then,
take care switching to avoid traffic interruption.RX
SW Condition-Early Warning
1. Included Early Warning, this switch over the RX SW at
less than 1E-9.
3-45
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
2. TAG LAN
VLAN ID (VID) is used for group identification which is
identify from the incoming packets. Packets can be sent/
received in the same group.
Acceptable VID range: 1 to 4094
Maximum number of VID: 64 groups.
Each VID allow incoming data without TAG or discard/
forward data by TAG addition
3-46
Submission Prohibited
NEC Internal Use Only
ROI-S05749
SYSTEM SETUP
3-47
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
3-48
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
(2)
Port VLAN
TAG VLAN
Interface Card
(a)
4P LAN INTFC-E
(b)
GbE INTFC-E
(3)
Port + TAG
VLAN
(4)
Double
TAG VLAN
OLD
3.03 or less
3.03 or less
NEW
3.04 or more
3.04 or more
3-49
Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP
ROI-S05749
(a)
4P LAN INTFC-E
(b)
GbE INTFC-E
3-50
50 pages
(1)
IEEEE802.1q
CoS
(2)
DSCP
(3)
ToS