Вы находитесь на странице: 1из 134

Submission Prohibited

NEC Internal Use Only


CONTENTS

ROI-S05749-05UE
April, 2010

PASOLINK NEO
6-52 GHz PDH/SDH DIGITAL RADIO SYSTEM

Section II OPERATION
CONTENTS
TITLE

PAGE

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

OPERATING EQUIPMENT. . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

2.1

IDU Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

2.2

CTRL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

2.3

MODEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12

2.4

48E1 INTFC (I/O BOARD) . . . . . . . . . . . . . . . . . . . . . . . 2-16

2.5

32E1 INTFC (I/O BOARD) . . . . . . . . . . . . . . . . . . . . . . . 2-30

2.6

16E1 INTFC (I/O BOARD) . . . . . . . . . . . . . . . . . . . . . . . 2-40

2.7

STM-1 INTFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45

2.8

E3 INTFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48

2.9

LAN/WS INTFC (Optional). . . . . . . . . . . . . . . . . . . . . . . 2-52

2.10

4P LAN INTFC (Optional) . . . . . . . . . . . . . . . . . . . . . . . 2-56

2.11

GbE INTFC (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . 2-60

2.12

4P LAN INTFC-E (Optional) . . . . . . . . . . . . . . . . . . . . . 2-64

2.13

Gbe INTFC-E (Optional) . . . . . . . . . . . . . . . . . . . . . . . . 2-68

2.13.1

Port 1 (GbE Usage). . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68

2.13.2

Port 2-4 (10/100BASE-T Usage) . . . . . . . . . . . . . . . . . 2-71

2.14

DC-DC CONV (Optional) . . . . . . . . . . . . . . . . . . . . . . . 2-74

2.15

ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-76

SYSTEM SETUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

3.1

Equipment Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

3.2

Provisioning Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7

3.3

Events and Performance . . . . . . . . . . . . . . . . . . . . . . . 3-14

3.4

Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22

3.5

Setup Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24

3.5.1

Automatic Laser Shutdown Control


(OPT INTFC) (SDH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24

CL-1

Submission Prohibited
NEC Internal Use Only
CONTENTS

CL-2
2 pages

ROI-S05749

3.5.2

Automatic Protection Switching (APS)


(OPT INTFC Optional APS Configuration) (SDH) . . . . 3-26

3.5.3

Automatic Transmitter Power Control . . . . . . . . . . . . 3-31

3.5.4

Loopback Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36

3.5.5

Link Loss Forwarding Control


(LAN and Link Down for VLAN) . . . . . . . . . . . . . . . . . . 3-37

3.5.6

MS-AIS Generation (SDH). . . . . . . . . . . . . . . . . . . . . . . 3-37

3.5.7

Cross Polarization Interference Canceller


(XPIC) Reset Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-39

3.5.8

Network Management (Optional) . . . . . . . . . . . . . . . . . 3-40

3.5.9

Functionality Classification. . . . . . . . . . . . . . . . . . . . . 3-41

3.6

Protection Switching. . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42

3.6.1

1+1 Twin-path System. . . . . . . . . . . . . . . . . . . . . . . . . . 3-42

3.6.2

Hot-standby System . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42

3.6.3

Switchover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44

3.7

2-WAY/XC Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46

3.8

VLAN Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46

3.9

QoS Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50

Submission Prohibited
NEC Internal Use Only
GENERAL

ROI-S05749

1. GENERAL
This section provides instructions for operation of the 6 to 52 GHz PDH/
SDH radio system.
This section describes interface terminals and jacks, controls, indicators,
and test jacks. Use of the LCT is required for local operation, monitoring,
control and setup. For details of system and provisioning setup, refer to
Section IV PASOLINK NEO LCT Operation.

1-1

Submission Prohibited
NEC Internal Use Only
GENERAL

ROI-S05749

PASOLINK NEO IDU


MODEM(1)

INTFC (1)

MDP-150MB-1AA
INDOOR UNIT

INTFC (2)

CTRL

MODEM(2)

0678
DATE 2007-09 (H2930)
(WITH OPTION)
(WITH ODU & OPTION)

SER. No. 123456


WEIGHT: 4 kg
48 V
2.5A

NEC Corporation TOKYO JAPAN

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

MADE IN JAPAN

PULL
ALM
PWR

2M IN/OUT-B

2M IN/OUT-A

100M

PORT 1

PORT 2

100M

PROTECT

(Blank)
LCT

NMS

MAINT
MEMORY
IDU

AUX/ALM

NE

PASOLINK NEO

SC IN/OUT

EOW

CALL

MMC

IDU 1+0
*1
! IF IN/OUT

XIF IN XIF OUT


G

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL
ALM

2M IN/OUT-B

2M IN/OUT-A

PWR

100M

LCT

NMS

100M

2-WAY
G

MAINT
MEMORY
IDU

AUX/ALM

NE

PORT 2

PASOLINK NEO

PROTECT

PULL
PWR

PORT 1

SC IN/OUT

EOW

CALL

MMC

IDU 1+1

Note: *1:When a 2-WAY label is put on the 16E1 INTFC, the 2-WAY/XC mode is available.
*2
! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL
ALM

WS

PWR

100M

PORT 1

PORT 2

100M

WS IN/OUT

M.S

LCT

NMS

NE

AUX/ALM

PASOLINK NEO

PROTECT

MAINT
MEMORY
IDU

(Blank)
SC IN/OUT

EOW

CALL

MMC

Equipped with LAN/WS Interface for Main LAN (SDH)

Note: *2:When a M.S label is put on the LAN/WS INTFC, exclusive Main LAN mode is available.
*3
! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

G PULL
ALM
PWR

2M IN/OUT-B

2M IN/OUT-A

100M

PORT 1

PORT 2

PROTECT

(Blank)
LCT

NMS

NE

AUX/ALM

100M

156MB

PASOLINK NEO
MAINT
MEMORY
IDU

SC IN/OUT

EOW

CALL

MMC

Equipped with High Capacity 32E1 Interface with 2 Port LAN Interface (H2990D)

Note:*3:When a 156MB label is put on the 32E1 INTFC, the 156MB mode is available.
.

1-2

Submission Prohibited
NEC Internal Use Only
GENERAL

ROI-S05749

PASOLINK NEO ODU

PASOLINK NEO

0678

TRP-6G-1B
OUTDOOR UNIT
SHIFT FREQ 161MHz

(NWA-009024)

(NHG)

TX LOW
SERIAL No.
WEIGHT

123456
/
4kg
NEC Corporation

A
7725MHz
2007-09
0.5A

SUB BAND
TX FREQ
DATE
- 48V

TOKYO JAPAN

MADE IN JAPAN

-48V INPUT

CAUTION
Non-ionizing
radiation

Power down IDU before


disconnection or
connection of cable.

0678

PASOLINK NEO

(NWA-034274)
TRP-7G-5B
OUTDOOR UNIT (NHG2)
SHIFT FREQ 154MHz
SUB BAND A
RX LEV
MON

IFL

FG

TX LOW
SERIAL No.
WEIGHT

123456
/
3kg
NEC Corporation

2008-01
0.5A

DATE
- 48V
TOKYO JAPAN

CAUTION
Non-ionizing
radiation

6-38 GHz ODU NHG Type


6-11 GHz ODU NHG2 Type
52 GHz ODU Mx Type

MADE IN JAPAN

CAUTION
HOT SURFACE
Avoid contact.

PASOLINK Mx

0678

TRP-52G-5A
OUTDOOR UNIT
SHIFT FREQ 661MHz

(H0356B)

TX LOW
SERIAL No. 123456
4kg
WEIGHT

NEC Corporation

SUB BAND
TX FREQ
DATE
- 48V

A
51454MHz
2007-09
0.5A

TOKYO JAPAN

MADE IN JAPAN

-48V INPUT

CAUTION
Non-ionizing
radiation

Power down IDU before


disconnection or
connection of cable.

For 52 GHz band, the TRP-52G-5A ODU


(PASOLINK Mx) is used for NEO.

0678

PASOLINK NEO

(NWA-034278)
TRP-13G-5B
OUTDOOR UNIT (NHG2)
SHIFT FREQ 266MHz
SUB BAND A

TX LOW
SERIAL No. 123456
3kg
WEIGHT

NEC Corporation

DATE
- 48V
TOKYO JAPAN

CAUTION
Non-ionizing
radiation

-48V
IFL

2008-01
0.5A
MADE IN JAPAN

CAUTION
HOT SURFACE
Avoid contact.

For ODU NHG2 Type


RX LEV MON

13-38 GHz ODU NHG2 Type

1-3

Submission Prohibited
NEC Internal Use Only
GENERAL

ROI-S05749

(This page is intentionally left blank.)

1-4
4 pages

Submission Prohibited
NEC Internal Use Only
ROI-S05749

OPERATING EQUIPMENT

2. OPERATING EQUIPMENT
The indicators, switches, interface terminals and jacks for wiring with the
associated equipment are described here.
The IDU component modules listed in Table 2-1 are plugged-in from front
of the IDU shelf as shown in Fig. 2-1.
The ODU Equipment Type is shown in Fig. 2-2 and Table 2-2.
Note: Use shielded cables which are connected to the D-Sub/RJ-45
connector to suppress interference from affecting the signal and
to reduce electromagnetic radiation which may interfere with
other signal cables.
Note: Twist power cables (+)/() to suppress inductive interference
signals.

2-1

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2
! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL

PWR

G
PROTECT

3
LCT

NMS

NE

PASOLINK NEO
MAINT
MEMORY
IDU

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL
PWR

G
PROTECT

3
LCT

NMS

NE

AUX/ALM

SC IN/OUT

PASOLINK NEO
MAINT
MEMORY
IDU

EOW

CALL

MMC

7
Fig. 2-1 IDU Composition
Table 2-1 IDU Composition
H2930 MDP-150MB-1AA
No.

Unit/Module Name

H2931

RACK

H2940

MODEM

H2940

MODEM

H3040

DC-DC CONV

H2960

STM-1 INTFC

H2965

LAN/WS INTFC

H3021

GbE INTFC

H2960

STM-1 INTFC

H2965

LAN/WS INTFC

H2980

16E1 INTFC

H2990

32E1 INTFC

H3000

48E1 INTFC

H3010

E3 INTFC

H3020

4P LAN INTFC

H03022A 4P LAN INTFC-E


H03022B GbE INTFC-E
H03022C GbE INTFC-E
7

H2950

CTRL

Remarks

Expandable
1+0 system

1+1 system

()
()
()
()
()
()
()
()
()
()
()
()
()
()

QPSK/16QAM/32QAM/128QAM *1

20 to 60/+20 to +60 VDC *2


STM1-E/O-S-1.1/L-S-1.1 *3
2-Port-LAN *3
GbE
STM1-O-S-1.1/L-S-1.1 *3 for APS
WS-SC-LAN/WS/SC-LAN *3
16E1 e/w 2 Port LAN*3
32E1 e/w 2 Port LAN
48E1
E3 e/w 4/8E1, 2 Port LAN *3
4P LAN e/w 8E1
4P VLAN e/w 8E1
VLAN, 1000BASE-SX
VLAN, 1000BASE-LX

Notes: : Usually provides.


(): Optionally provides.
*1: Selectable in setting program.
*2: For expanding power supply range when the
PASOLINK+ ODU (EHG) is connected to the IDU
NEO.
*3: Selectable by changing the module type.

2-2

Submission Prohibited
NEC Internal Use Only
ROI-S05749

RX LEV
MON

IFL

FG
-48V
IFL

RX LEV MON

ODU
13-38 GHz ODU (NHG2 Type)

ODU
6-38 GHz (NHG type)/52 GHz (Mx Type)
6-11 GHz ODU (NHG2 Type)
Fig. 2-2 ODU Equipment Type

Table 2-2 ODU Type vs. Frequency


7 GHz

8 GHz

10 GHz

11 GHz

13 GHz

15 GHz

18 GHz

23 GHz

26 GHz

28 GHz

32 GHz

38 GHz

TRP-( )G-1B
(NHG Type)
(Mx Type)

NWANWANWANWANWANWANWANWANWANWANWANWANWA009024-( ) 009026-( ) 009028-( ) 009030-( ) 009032-( ) 009034-( ) 009036-( ) 009038-( ) 009040-( ) 009042-( ) 009044-( ) 009046-( ) 009048-( )

TRP-( )G-5B
(NHG2 Type)

NWANWANWA034273-( ) 034274-( ) 034275-( )

NWA034276-( )

NWA034277-( )

NWA034278-( )

NWA034279-( )

NWA034280-( )

NWA034281-( )

NWA034282-( )

-----

NWANWA034284-( ) 034285-( )

52 GHz

H0356B

------

2-3

OPERATING EQUIPMENT

6 GHz

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.1 IDU Shelf

New Type Shelf


G

Jack (IDU)

Electrostatic Discharge (ESD) jack used to connect


wrist strap band.

Caution*:Engineers for maintenance of the equipment must take the


necessary steps to avoid bit errors or cause damage to the
modules due to electrostatic discharge. Wear a conductive
wrist strap connected to the ground jack (G) on the front of
the IDU to minimize static build-up during maintenance.

2-4

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.2 CTRL
CALL
PROTECT

NE
NMS
LCT

PASOLINK NEO

PROTECT

LCT

NMS

NE

AUX/ALM

AUX/ALM

MMC

MAINT
MEMORY
IDU
SC IN/OUT

SC IN/OUT

EOW

CALL

EOW
*

MMC

MAINT(amber)
MEMORY(amber)
IDU(red)

Caution*
PROTECT SW is provided only for the CTRL panel replacement. Set PROTECT SW to OFF position (bottom
side) in normal operation. Equipment may not work properly if the PROTECT SW is set to ON position (Upper
side) by mistake.
Refer to ROI-S05751 MAINTENANCE manual for the CTRL panel replacement.

The CTRL generates various control signals based upon LCT setup data
and gathered operating status in the IDU and from the ODU, has SC,
EOW, LAN, NE, EXT ALM, HK, Cluster ALM signals interface. By
Connecting a PC, manual control, performance monitoring and system
setup can be performed.

Interface Signals (CTRL)

AUX/ALM (D-Sub
Female 44 pins)
Input/Output Signal
EOW:

1 CH

Frequency:

0.3 to 3.4 kHz (1020 Hz (Test Tone))

Level:

6 dBm

Impedance:

600 ohms

ALM:

ALM 6 outputs/6 HK Inputs/4 HK Control outputs,


Cluster 4 Inputs/outputs

Output:

Relay contact Form-C

Input:

Photocoupler

Bz 1,2 IN:

Signalling control extension input.

Call 1,2 OUT:

Signalling control extension output.

EOW:

EOW headphone jack

2-5

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Interface Signals (CTRL)

SC IN/OUT (D-Sub
Female 44 pins)
Input/Output Signal
NE2:

Network Element

Level:

RS-485

DSC (RS-232C):

2 CH

Bit rate:

9600 bps

Level:

RS-232C

DSC (V.11):

2 CH

Bit rate:

64 Kbps

Level:

V.11

Impedance:

100 ohms

NE (RJ-45):

Network Element

Level:

10BASE-T

LCT (USB):

Serial interface USB-B type connector with PC

NMS (RJ-45):

PNMS

Level:

10BASE-T

Indicators (CTRL)
LED

MAINT

Indication

Remarks

Maintenance mode can be


Actively blinks: In progress of program data download.
selected by LCT, PNMT and Inactively blinks:Protect Mode for CTRL replacement
PNMS
into effect.
The maintenance Mode
ON is selected.

MEMORY Memory Card (MMC) status. ON: Enable access to Memory Card
OFF: Disable access to Memory Card
Blinks: Accessing Memory Card
IDU

IDU Summary alarm.

Check ALM LEDs on each module to find the cause


and/or connect LCT to check the performance condition.
When any INTFC module is not mounted, ALM LED
will light.
Blinks: CPU or peripheral event occurred.

2-6

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Switch (CTRL)
Switch

Operating

CALL

Transmits EOW calling signal to sound the


buzzer in the opposite station.

PROTECT

Prevent service interruption when the CTRL


module is replaced.

Remarks

Accessing the Memory Card (MMC)


is required to apply the function.

User Interface Pin Assignment (CTRL)


Terminal

Description

CTRL
ALM/AUX IN/OUT
(D-sub Female, 44 Pins)

Service channel data input/output

Pins 1 (+) and 16 ()

EOW input 1

Pins 2 (+) and 17 ()

EOW output 1

Pins 3 (+) and 18 ()

EOW input 2

Pins 4 (+) and 19 ()

EOW output 2

Pin 5

Ground

Pins 25 (COM), 40 (NC)


and 11 (NO) RL1*1

Maintenance alarm output


Between
Pins 25 and 40
Closed
Open

Between
Pins 25 and 11
Open
Closed

Pins 24 (COM), 39 (NC)


and 10 (NO) RL2*1

IDU CPU/PS1/PS2 alarm output


Between
Pins 24 and 39
Normal state
:
Closed
Alarm state
:
Open

Between
Pins 24 and 10
Open
Closed

Pins 23 (COM), 38 (NC)


and 9 (NO) RL3

ODU1/ODU2 alarm output*2


Between
Pins 23 and 38
Normal state
:
Closed
Alarm/Event state :
Open

Between
Pins 23 and 9
Open
Closed

Normal state
Alarm state

:
:

2-7

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (CTRL)


Terminal

Description

Pins 22 (COM), 37 (NC)


and 8 (NO) RL4

ODU CPU1/ODU CPU2/Cable Open alarm output*2


Between
Between
Pins 22 and 37
Pins 22 and 8
Normal state
:
Closed
Open
Alarm/Event state :
Open
Closed

Pins 21 (COM), 36 (NC)


and 7 (NO) RL5

IDU total alarm output*2


Between
Pins 21 and 36
Closed
Open

Between
Pins 21 and 7
Open
Closed

Pins 20 (COM), 35 (NC)


and 6 (NO) RL6

High BER1/High BER2 alarm output*2


Between
Pins 20 and 35
Normal state
:
Closed
Alarm/Event state :
Open

Between
Pins 20 and 6
Open
Closed

Pins 15 (+) and 14 ()

HK1 alarm input*3


Normal state
:
Control/Event state :

Open
Closed

HK2 alarm input*3


Normal state
:
Control/Event state :

Open
Closed

Normal state
Alarm/Event state

Pins 13 (+) and 12 ()

2-8

:
:

Pins 29 (+) and 28 ()

HK3/Cluster4 alarm input*3


Normal state
:
Open
Control/Event state :
Closed

Pins 27 (+) and 26 ()

HK4/Cluster3 alarm input*3


Normal state
:
Open
Control/Event state :
Closed

Pins 44 (+) and 43 ()

HK5/Cluster2 alarm input*3


Normal state
:
Open
Control/Event state :
Closed

Pins 42 (+) and 41 ()

HK6/Cluster1 alarm input*3


Normal state
:
Open
Control/Event state :
Closed

Pin 30

Buzzer input 1

Pin 31

Call output 1

Pin 32

Buzzer input 2

Pin 33

Call output 2

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (CTRL)


Terminal

Description

CTRL
SC IN/OUT
(D-sub Female, 44 Pins)

NE2/DSC Service channel data input/output

Pins 1 (+) and 2 ()

NE2 TXD

Pin 3

Ground

Pins 4 (+) and 5 ()

V.11-1 TX data input

Pins 6 (+) and 7 ()

V.11-1 RX data output

Pins 8 (+) and 9 ()

V.11-2 TX data input

Pins 10 (+) and 11 ()

V.11-2 RX data output

Pins 12 and 13 (G)

RS-232C-1 data input

Pins 14 and 15 (G)

RS-232C-2 data input

Pin 16

NE2 RXD TERM

Pins 17, 18

Ground

Pins 19 (+) and 20 ()

V.11-1 TX clock input (co-dir.) or output (contra-dir.) *4

Pins 21 (+) and 22 ()

V.11-1 RX clock output

Pins 23 (+) and 24 ()

V.11-2 TX clock input (co-dir.) or output (contra-dir.) 4*

Pins 25 (+) and 26 ()

V.11-2 RX clock output

Pins 27, 28, 29

Ground

Pins 30 (+) and 31 ()

NE2 RXD

Pin 32

Ground

Pins 33 (+) and 34 ()

V.11-1 TX frame pulse input (co-dir.) or output (contra-dir.) *4

Pins 35 (+) and 36 ()

V.11-1 RX frame pulse output

Pins 37 (+) and 38 ()

V.11-2 TX frame pulse input (co-dir.) or output (contra-dir.) *4

Pins 39 (+) and 40 ()

V.11-2 RX frame pulse output

Pins 41 and 42 (G)

RS-232C-1 data output

Pins 43 and 44 (G)

RS-232C-2 data output

2-9

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (CTRL)


Terminal

LCT
(USB connector type B)

Description

Local craft terminal (LCT) data input/output

Pin 1

Vbus

Pins 2 () and 3 (+)

Pin 4

Ground

NMS (RJ-45)

PNMS data (10BASE-T) input/output

Pins 1 (+) and 2 ()

NMS TXD

Pins 3 (+) and 6 ()

NMS RXD

Pins 4, 5, 7 and 8

Not Connected

NE (RJ-45)

NE data (10BASE-T) input/output

Pins 1 (+) and 2 ()

NMS TXD

Pins 3 (+) and 6 ()

NMS RXD

Pins 4, 5, 7 and 8

Not Connected
Notes: *1: RL1 (Maintenance) and RL2 (IDU CPU/PS1/PS2
ALM OUTUT) are fixed and can not be changed to
other items. The relay contact is rated at 0.2 A.
*2: These alarm items are assigned at the factory (default
setting) and can be changed by the LCT as shown in
Table 2-3 in Section 1 (Alarms may be selectively
assigned to RL3 to RL6).
*3: Photocoupler interface; resistance of open input
terminal is more than 200 kilo ohms. Closed input
terminal is less than 50 ohms.
*4: V11 interface for the TX clock and frame pulse input/
output depend on co-/contra-directional mode setting
in the LCT provisioning menu.

2-10

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

EOW Connection

When EOW signal is connected between two IDUs, perform wiring as follows.

Terminal Station A

EOW 4W S

EOW 4W R

Buzzer IN
Call OUT

Back -to- Back Station B

1
2
3
4

1
2
3
4

16
17
18
19

16
17
18
19

30
31
32
33

30
31
32
33

IDU Dir. B
ALM/AUX IN/OUT
(D-Sub, 44 Pins)

EOW
4W S

1
2
3
4

EOW
4W R

16
17
18
19

Buzzer IN
Call OUT

IDU Dir. A
ALM/AUX IN/OUT
(D-Sub, 44 Pins)

EOW
Extension

30
31
32
33

IDU Dir. C
ALM/AUX IN/OUT
(D-Sub, 44 Pins)

2-11

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.3 MODEM
FG (Frame Ground)

TX (green)
RX (green)
XPIC RESET(amber)

IF IN/OUT

PWR (green) SELV


ODU (red)
MD/CBL (red)

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

XPIC CTRL
XIF OUT
XIF IN

PULL
PWR

PWR

Caution: Do not apply to the equipment a voltage that varies sharply. The equipment
may operate wrongly.
Caution: Do not remove/connect the IF cable with the IDU power ON, Turn the IDU
power OFF before connecting/disconnecting the IF cable, or equipment may
be damaged.
Caution: Do not insert/extract the MODEM with the power ON, turn the IDU power
OFF and remove all cables connected to the MODEM before insert/extract the
MODEM, or MODEM may be damaged.
Caution: The top surface of the IDU shelf above MODEM is hot in operation.
The MODEM provides the QPSK/16QAM/32QAM/128QAM
Modulation/Demodulation for E1/E3 (PDH), 10/100BASE-T(X)/
1000BASE-T (LAN) or STM-1 (SDH) data transmission and following
main functions.
- Forward Error Correction using RS/Interleave
- BER (High BER/Low BER) detection/indication/release for internal
and external
- Reducing ODU output signal distortion using BB Linearizer
- Equalization using Transversal Equalizer
- XPIC ODU synthesizer synchronization control
- Interfered signal from opposite polarization cancellation (XPIC)
- IDU/ODU power supply
- System power on/off

2-12

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Interface Signals (MODEM)

IF IN/OUT (TNC Female)


TX Frequency:

340 MHz

RX Frequency:

140 MHz

Power supply:

48 V

Impedance:

50 ohms
Connecting IF Cable length:
5D-FB: less than 150 m
8D-FB: less than 300 m

FG (Screw):

Frame Ground terminal


(5 mm square cable (more than 2.5 mm diameter
cable) (AWG#10) is recommended to apply for the
frame ground. The proper press fix terminal tool
shall be used.)

SELV (Molex M5569-04A1,


4 pins) (DC IN)
Input Voltage:
XIF IN/XIF OUT
(Receptacle IEC 169-13 (1.0/
2.3))

48 V DC (negative), + (positive, ground)


Only used for XPIC system between two IDUs

XIF IN:

IF signal of opposite polarization input.


(connect to XIF OUT of the other MODEM)

XIF OUT:

IF signal for opposite polarization output.


(connect to XIF IN of the other MODEM)

Frequency:

140 MHz

Impedance:

75 ohms

XPIC CTRL
(D-Sub 15 pins, Serial Port)

Only used for XPIC system between two IDUs


(connect to XPIC CTRL of the other MODEM)

Automatic/Remote XPIC reset control signal interface between mutual MODEM.

2-13

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (MODEM)
LED

PWR

Indication

Remarks

The PWR switch of the MODEM is turned


on.

DC power is supplied to the


ODU also.

Transmit RF power of the ODU decreased


approx. 3 dB from preadjusted ATPC
minimum (MIN) level in provisioning.

Check Metering using LCT for


local and/or opposite site in
Maintenance menu

Receiver input level of the ODU falls below


squelch level.
APC loop of local oscillator in ODU is
unlocked.

ODU

IF signal from the MODEM to ODU is lost.


Blinks when IF cable is open circuit.
Connected ODU is not matched with
inventory.
MD/CBL

Blinks when IF cable is short circuit.

TX (only 1+1)

Selected status of ODU TX

When TX mute control: LED


Off

RX (only 1+1)

Selected status of MODEM RX output signal

When RX SWO switched to


opposite: LED Off

XPIC RESET

XPIC function is OFF condition

Only XPIC configuration.


Propagation condition
deteriorated or XPIC is reset
from LCT control.

Switches (MODEM)
Switch

PWR

2-14

Operating

IDU and ODU power On/Off switch.

Remarks

Refer to Start-up and Shut-down the


Equipment in Maintenance Section

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (MODEM)


Terminal

Description

SELV
SELV (DC IN)
(Molex M5569-04A1 Connector,
4 Pins)

48 V DC power input
Note: Only 48 V (40.5 to 57 V) is available.

Pins 1 and 3

Ground

Pins 2 and 4

48 V

IF IN/OUT
TNC Jack (Female) *

IF signal IN/OUT and PS OUT to the ODU

XPIC CTRL
(D-Sub Female, 15 pins)

Used for interconnection


configuration.

Pins 1 (+) and 6 ()

XPIC SV TXD

Pins 2 (+) and 7 ()

XPIC SV RXD

Pin 3

Ground

Pins 4 (+) and 9 ()

XPIC SEL IN

Pins 5 (+) and 10 ()

XPIC SEL OUT

Pins 8 (+) and 12 ()

XPIC RESET IN

Pin 11

Ground

Pins 13 () and 14 (+)

XPIC RESET OUT

Pin 15

Ground

between

IDUs

in

XPIC

Note: *: It is recommended that TNC (Male) L-angle connector for the


8D-FB IF cable is used to connect it to the IDU. When the N
(Male) straight connector is attached to the 5D-FB IF cable,
use of the TNC (Male) - N (Female) (NJ-TNCP-LA) L-angle
adapter is needed.

2-15

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.4 48E1 INTFC (I/O BOARD)

ALM
2M IN/OUT-A

2M IN/OUT-A

2M IN/OUT-B

2M IN/OUT-C

2M IN/OUT-B

2M IN/OUT-C

ALM LED (red)

Caution: Do not insert/extract the 48E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 48E1 INTFC before insert/extract the 48E1
INTFC, or 48E1 INTFC may be damaged.
Optional I/O BOARD
Following I/O BOARD can be provided when the D-SUB 37 pins interface is required to the 2M IN/OUT INTFC
instead of MDR interface.
D-Sub 37 pins Connector
6 D-Sub Connectors are provided for 48E1.

H3042K I/O BOARD


SER No.
DATE
WEIGHT kg
MADE IN JAPAN

2M IN/OUT-A

2M IN/OUT-A

2M IN/OUT-A

2M IN/OUT-B

2M IN/OUT-B

2M IN/OUT-B

H3009A I/O BOARD


SER No.
DATE
WEIGHT kg
MADE IN JAPAN

H3009A I/O BOARD


SER No.
DATE
WEIGHT kg
MADE IN JAPAN

H3009A I/O BOARD


SER No.
DATE
WEIGHT kg
MADE IN JAPAN

CH1 to CH8
CH9 to CH16

CH17 to CH24 CH33 to CH40


CH25 to CH32 CH41 to CH48
User Interface
MDR 68 pins Connector

Note: One Unit space is necessary to install I/O BOARD above IDU.

The 48E1 INTFC applies for up to 48E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.

2-16

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

The user interface signals conform to ITU-T as listed in the following


tables.

Interface Signals (48E1 INTFC)

2M IN/OUT-A/-B/-C
(MDR Connector)

16E1 interface in each 3 connectors.

Input/Output Signal:

Up to 48E1 signals

Bit Rate:

2.048 Mbps +/102.4 bitps

Code:

HDB3

Impedance:

75 ohms unbalanced or 120 ohms balanced *


Note: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.

Indicators (48E1 INTFC)


LED

ALM

Indication

Remarks

LOS from DTE is detected.

Check DTE and wiring.

Loss of output signal to DTE is detected.

Perform Far End loopback test.

Error of channel usage.

Signal is applied to unused channel.

Mounting module
inventory.

is

not

matched

with

Change LCT setting or other ( )INTFC


module.

2-17

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 INTFC)


Terminal

Description

48E1 INTFC
2M IN/OUT-A
(CH 1 to CH 16)
(MDR Connector, 68 pins)

2.048 Mbps HDB3 coded data signal input/output from/to


DTE
(CH 1 to CH 16), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-18

Pins 1, 34, 35 and 68

Ground

Pins 33 (+) and 67 ()

CH1 data output

Pins 32 (+) and 66 ()

CH1 data input

Pins 31 (+) and 65 ()

CH2 data output

Pins 30 (+) and 64 ()

CH2 data input

Pins 29 (+) and 63 ()

CH3 data output

Pins 28 (+) and 62 ()

CH3 data input

Pins 27 (+) and 61 ()

CH4 data output

Pins 26 (+) and 60 ()

CH4 data input

Pins 25 (+) and 59 ()

CH5 data output

Pins 24 (+) and 58 ()

CH5 data input

Pins 23 (+) and 57 ()

CH6 data output

Pins 22 (+) and 56 ()

CH6 data input

Pins 21 (+) and 55 ()

CH7 data output

Pins 20 (+) and 54 ()

CH7 data input

Pins 19 (+) and 53 ()

CH8 data output

Pins 18 (+) and 52 ()

CH8 data input

Pins 17 (+) and 51 ()

CH9 data output

Pins 16 (+) and 50 ()

CH9 data input

Pins 15 (+) and 49 ()

CH10 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 INTFC)


Terminal

Description

Pins 14 (+) and 48 ()

CH10 data input

Pins 13 (+) and 47 ()

CH11 data output

Pins 12 (+) and 46 ()

CH11 data input

Pins 11 (+) and 45 ()

CH12 data output

Pins 10 (+) and 44 ()

CH12 data input

Pins 9 (+) and 43 ()

CH13 data output

Pins 8 (+) and 42 ()

CH13 data input

Pins 7 (+) and 41 ()

CH14 data output

Pins 6 (+) and 40 ()

CH14 data input

Pins 5 (+) and 39 ()

CH15 data output

Pins 4 (+) and 38 ()

CH15 data input

Pins 3 (+) and 37 ()

CH16 data output

Pins 2 (+) and 36 ()

CH16 data input

2-19

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 INTFC)


Terminal

Description

48E1 INTFC
2M IN/OUT-B
(CH 17 to CH 32)
(MDR Connector, 68 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 17 to CH 32), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-20

Pins 1, 34, 35 and 68

Ground

Pins 33 (+) and 67 ()

CH17 data output

Pins 32 (+) and 66 ()

CH17 data input

Pins 31 (+) and 65 ()

CH18 data output

Pins 30 (+) and 64 ()

CH18 data input

Pins 29 (+) and 63 ()

CH19 data output

Pins 28 (+) and 62 ()

CH19 data input

Pins 27 (+) and 61 ()

CH20 data output

Pins 26 (+) and 60 ()

CH20 data input

Pins 25 (+) and 59 ()

CH21 data output

Pins 24 (+) and 58 ()

CH21 data input

Pins 23 (+) and 57 ()

CH22 data output

Pins 22 (+) and 56 ()

CH22 data input

Pins 21 (+) and 55 ()

CH23 data output

Pins 20 (+) and 54 ()

CH23 data input

Pins 19 (+) and 53 ()

CH24 data output

Pins 18 (+) and 52 ()

CH24 data input

Pins 17 (+) and 51 ()

CH25 data output

Pins 16 (+) and 50 ()

CH25 data input

Pins 15 (+) and 49 ()

CH26 data output

Pins 14 (+) and 48 ()

CH26 data input

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 INTFC)


Terminal

Description

Pins 13 (+) and 47 ()

CH27 data output

Pins 12 (+) and 46 ()

CH27 data input

Pins 11 (+) and 45 ()

CH28 data output

Pins 10 (+) and 44 ()

CH28 data input

Pins 9 (+) and 43 ()

CH29 data output

Pins 8 (+) and 42 ()

CH29 data input

Pins 7 (+) and 41 ()

CH30 data output

Pins 6 (+) and 40 ()

CH30 data input

Pins 5 (+) and 39 ()

CH31 data output

Pins 4 (+) and 38 ()

CH31 data input

Pins 3 (+) and 37 ()

CH32 data output

Pins 2 (+) and 36 ()

CH32 data input

2-21

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 INTFC)


Terminal

Description

48E1 INTFC
2M IN/OUT-C
(CH 33 to CH 48)
(MDR Connector, 68 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 33 to CH 48), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-22

Pins 1, 34, 35 and 68

Ground

Pins 33 (+) and 67 ()

CH33 data output

Pins 32 (+) and 66 ()

CH33 data input

Pins 31 (+) and 65 ()

CH34 data output

Pins 30 (+) and 64 ()

CH34 data input

Pins 29 (+) and 63 ()

CH35 data output

Pins 28 (+) and 62 ()

CH35 data input

Pins 27 (+) and 61 ()

CH36 data output

Pins 26 (+) and 60 ()

CH36 data input

Pins 25 (+) and 59 ()

CH37 data output

Pins 24 (+) and 58 ()

CH37 data input

Pins 23 (+) and 57 ()

CH38 data output

Pins 22 (+) and 56 ()

CH38 data input

Pins 21 (+) and 55 ()

CH39 data output

Pins 20 (+) and 54 ()

CH39 data input

Pins 19 (+) and 53 ()

CH40 data output

Pins 18 (+) and 52 ()

CH40 data input

Pins 17 (+) and 51 ()

CH41 data output

Pins 16 (+) and 50 ()

CH41 data input

Pins 15 (+) and 49 ()

CH42 data output

Pins 14 (+) and 48 ()

CH42 data input

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 INTFC)


Terminal

Description

Pins 13 (+) and 47 ()

CH43 data output

Pins 12 (+) and 46 ()

CH43 data input

Pins 11 (+) and 45 ()

CH44 data output

Pins 10 (+) and 44 ()

CH44 data input

Pins 9 (+) and 43 ()

CH45 data output

Pins 8 (+) and 42 ()

CH45 data input

Pins 7 (+) and 41 ()

CH46 data output

Pins 6 (+) and 40 ()

CH46 data input

Pins 5 (+) and 39 ()

CH47 data output

Pins 4 (+) and 38 ()

CH47 data input

Pins 3 (+) and 37 ()

CH48 data output

Pins 2 (+) and 36 ()

CH48 data input

2-23

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-A
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-24

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH8 data input

Pins 3 (+) and 4 ()

CH7 data input

Pins 6 (+) and 7 ()

CH6 data input

Pins 8 (+) and 9 ()

CH5 data input

Pins 11 (+) and 12 ()

CH4 data input

Pins 13 (+) and 14 ()

CH3 data input

Pins 16 (+) and 17 ()

CH2 data input

Pins 18 (+) and 19 ()

CH1 data input

Pins 20 (+) and 21 ()

CH8 data output

Pins 22 (+) and 23 ()

CH7 data output

Pins 25 (+) and 26 ()

CH6 data output

Pins 27 (+) and 28 ()

CH5 data output

Pins 29 (+) and 30 ()

CH4 data output

Pins 31 (+) and 32 ()

CH3 data output

Pins 34 (+) and 35 ()

CH2 data output

Pins 36 (+) and 37 ()

CH1 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-B
(CH 9 to CH 16)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 9 to CH 16), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH16 data input

Pins 3 (+) and 4 ()

CH15 data input

Pins 6 (+) and 7 ()

CH14 data input

Pins 8 (+) and 9 ()

CH13 data input

Pins 11 (+) and 12 ()

CH12 data input

Pins 13 (+) and 14 ()

CH11 data input

Pins 16 (+) and 17 ()

CH10 data input

Pins 18 (+) and 19 ()

CH9 data input

Pins 20 (+) and 21 ()

CH16 data output

Pins 22 (+) and 23 ()

CH15 data output

Pins 25 (+) and 26 ()

CH14 data output

Pins 27 (+) and 28 ()

CH13 data output

Pins 29 (+) and 30 ()

CH12 data output

Pins 31 (+) and 32 ()

CH11 data output

Pins 34 (+) and 35 ()

CH10 data output

Pins 36 (+) and 37 ()

CH9 data output

2-25

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-A
(CH 17 to CH 24)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 17 to CH 24), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-26

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH24 data input

Pins 3 (+) and 4 ()

CH23 data input

Pins 6 (+) and 7 ()

CH22 data input

Pins 8 (+) and 9 ()

CH21 data input

Pins 11 (+) and 12 ()

CH20 data input

Pins 13 (+) and 14 ()

CH19 data input

Pins 16 (+) and 17 ()

CH18 data input

Pins 18 (+) and 19 ()

CH17 data input

Pins 20 (+) and 21 ()

CH24 data output

Pins 22 (+) and 23 ()

CH23 data output

Pins 25 (+) and 26 ()

CH22 data output

Pins 27 (+) and 28 ()

CH21 data output

Pins 29 (+) and 30 ()

CH20 data output

Pins 31 (+) and 32 ()

CH19 data output

Pins 34 (+) and 35 ()

CH18 data output

Pins 36 (+) and 37 ()

CH17 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-B
(CH 25 to CH 32)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 25 to CH 32), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH32 data input

Pins 3 (+) and 4 ()

CH31 data input

Pins 6 (+) and 7 ()

CH30 data input

Pins 8 (+) and 9 ()

CH29 data input

Pins 11 (+) and 12 ()

CH28 data input

Pins 13 (+) and 14 ()

CH27 data input

Pins 16 (+) and 17 ()

CH26 data input

Pins 18 (+) and 19 ()

CH25 data input

Pins 20 (+) and 21 ()

CH32 data output

Pins 22 (+) and 23 ()

CH31 data output

Pins 25 (+) and 26 ()

CH30 data output

Pins 27 (+) and 28 ()

CH29 data output

Pins 29 (+) and 30 ()

CH28 data output

Pins 31 (+) and 32 ()

CH27 data output

Pins 34 (+) and 35 ()

CH26 data output

Pins 36 (+) and 37 ()

CH25 data output

2-27

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-A
(CH33 to CH 40)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 33 to CH 40), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-28

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH40 data input

Pins 3 (+) and 4 ()

CH39 data input

Pins 6 (+) and 7 ()

CH38 data input

Pins 8 (+) and 9 ()

CH37 data input

Pins 11 (+) and 12 ()

CH36 data input

Pins 13 (+) and 14 ()

CH35 data input

Pins 16 (+) and 17 ()

CH34 data input

Pins 18 (+) and 19 ()

CH33 data input

Pins 20 (+) and 21 ()

CH40 data output

Pins 22 (+) and 23 ()

CH39 data output

Pins 25 (+) and 26 ()

CH38 data output

Pins 27 (+) and 28 ()

CH37 data output

Pins 29 (+) and 30 ()

CH36 data output

Pins 31 (+) and 32 ()

CH35 data output

Pins 34 (+) and 35 ()

CH34 data output

Pins 36 (+) and 37 ()

CH33 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (48E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-B
(CH41 to CH 48)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 41 to CH 48), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH48 data input

Pins 3 (+) and 4 ()

CH47 data input

Pins 6 (+) and 7 ()

CH46 data input

Pins 8 (+) and 9 ()

CH45 data input

Pins 11 (+) and 12 ()

CH44 data input

Pins 13 (+) and 14 ()

CH43 data input

Pins 16 (+) and 17 ()

CH42 data input

Pins 18 (+) and 19 ()

CH41 data input

Pins 20 (+) and 21 ()

CH48 data output

Pins 22 (+) and 23 ()

CH47 data output

Pins 25 (+) and 26 ()

CH46 data output

Pins 27 (+) and 28 ()

CH45 data output

Pins 29 (+) and 30 ()

CH44 data output

Pins 31 (+) and 32 ()

CH43 data output

Pins 34 (+) and 35 ()

CH42 data output

Pins 36 (+) and 37 ()

CH41 data output

2-29

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.5 32E1 INTFC (I/O BOARD)


PORT1
PORT2

2M IN/OUT-B

2M IN/OUT-A

ALM (red)

ALM
2M IN/OUT-B

2M IN/OUT-A

100M

PORT 1

PORT 2

100M

100M(green)
COLLISION/DUPLEX(amber)
LINK(green)

Caution: Do not insert/extract the 32E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 32E1 INTFC before insert/extract the 32E1
INTFC, or 32E1 INTFC may be damaged.
Following I/O BOARD can be provided when the D-SUB 37 pins interface is required to the 2M IN/OUT INTFC
instead of MDR interface.
4 D-Sub Connectors are provided for 32E1.

H3042K I/O BOARD


SER No.
DATE
WEIGHT kg
MADE IN JAPAN

2M IN/OUT-A

2M IN/OUT-A

2M IN/OUT-B

2M IN/OUT-B

H3009A I/O BOARD


SER No.
DATE
WEIGHT kg
MADE IN JAPAN

H3009A I/O BOARD


SER No.
DATE
WEIGHT kg
MADE IN JAPAN

CH1 to CH8
CH9 to CH16

CH17 to CH24
CH25 to CH32
User Interface

Note: One Unit space is necessary to install I/O BOARD above IDU.
The 32E1 INTFC applies for up to 32E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.
2 PORT LAN interface provides optionally to transmit up to 100 (156*)
Mbps LAN with/without E1 signals.
*Note:For High Capacity PDH 32E1(H2990D) interface.
The user interface signals conform to ITU-T/IEEE as listed in the
following tables. For the details, refer to Appendix LAN INTERFACE
(10/100BASE-T(X) Application and setting.
Only when the FPGA ROM Ver 3.01 or later is mounted, the ENH
NODAL Mode is supported.
The LAN transmission with the NEO/a (ENH NODAL) equipment is
come possible by using the ENH NODAL Mode.

2-30

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Interface Signals (32E1 INTFC)

2M IN/OUT-A/-B
(MDR Connector)

16E1 interface in each 2 connectors.

Input/Output Signal:

Up to 32E1 signals

Bit Rate:

2.048 Mbps +/102.4 bitps

Code:

HDB3

Impedance:

75 ohms unbalanced or 120 ohms balanced (*1)

PORT1/PORT2
(RJ-45) optional

LAN interface port 1 and 2 separated.


16 to 100 (156(*2)) Mbps shared when 32E1 to 0E1 are
used.

Input/Output Signal:

10/100BASE-T(X) Auto-sensing or fixed

Flow control:

Full duplex or Half duplex

Forwarding mode:

Store-and-Forwarding
Note: *1: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.
*2: For High Capacity PDH 32E1(H2990D) interface.

Indicators (32E1 INTFC)


LED

ALM

Indication

Remarks

LOS from DTE is detected.

Check DTE and wiring.

Loss of output signal to DTE is detected.

Perform Far End loopback test.

Error of channel usage.

Signal is applied to unused channel.

Mounting module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

LAN link failure occurs.

Check LAN cable connection.

100M

LAN signal is in 100BASE-TX mode.

LINK

LAN and associated equipment are linked


and flashing under the exchanging the
packet.

COLLISION/
DUPLEX

Input/Output LAN signal is in Full


Duplex mode. Flashing when a collision
condition occurs.

2-31

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 INTFC)


Terminal

Description

32E1 INTFC
2M IN/OUT-A
(CH 1 to CH 16)
(MDR Connector, 68 pins)

2.048 Mbps HDB3 coded data signal input/output from/to


DTE
(CH 1 to CH 16), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-32

Pins 1, 34, 35 and 68

Ground

Pins 33 (+) and 67 ()

CH1 data output

Pins 32 (+) and 66 ()

CH1 data input

Pins 31 (+) and 65 ()

CH2 data output

Pins 30 (+) and 64 ()

CH2 data input

Pins 29 (+) and 63 ()

CH3 data output

Pins 28 (+) and 62 ()

CH3 data input

Pins 27 (+) and 61 ()

CH4 data output

Pins 26 (+) and 60 ()

CH4 data input

Pins 25 (+) and 59 ()

CH5 data output

Pins 24 (+) and 58 ()

CH5 data input

Pins 23 (+) and 57 ()

CH6 data output

Pins 22 (+) and 56 ()

CH6 data input

Pins 21 (+) and 55 ()

CH7 data output

Pins 20 (+) and 54 ()

CH7 data input

Pins 19 (+) and 53 ()

CH8 data output

Pins 18 (+) and 52 ()

CH8 data input

Pins 17 (+) and 51 ()

CH9 data output

Pins 16 (+) and 50 ()

CH9 data input

Pins 15 (+) and 49 ()

CH10 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 INTFC)


Terminal

Description

Pins 14 (+) and 48 ()

CH10 data input

Pins 13 (+) and 47 ()

CH11 data output

Pins 12 (+) and 46 ()

CH11 data input

Pins 11 (+) and 45 ()

CH12 data output

Pins 10 (+) and 44 ()

CH12 data input

Pins 9 (+) and 43 ()

CH13 data output

Pins 8 (+) and 42 ()

CH13 data input

Pins 7 (+) and 41 ()

CH14 data output

Pins 6 (+) and 40 ()

CH14 data input

Pins 5 (+) and 39 ()

CH15 data output

Pins 4 (+) and 38 ()

CH15 data input

Pins 3 (+) and 37 ()

CH16 data output

Pins 2 (+) and 36 ()

CH16 data input

2-33

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 INTFC)


Terminal

Description

32E1 INTFC
2M IN/OUT-B
(CH 17 to CH 32)
(MDR Connector, 68 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 17 to CH 32), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-34

Pins 1, 34, 35 and 68

Ground

Pins 33 (+) and 67 ()

CH17 data output

Pins 32 (+) and 66 ()

CH17 data input

Pins 31 (+) and 65 ()

CH18 data output

Pins 30 (+) and 64 ()

CH18 data input

Pins 29 (+) and 63 ()

CH19 data output

Pins 28 (+) and 62 ()

CH19 data input

Pins 27 (+) and 61 ()

CH20 data output

Pins 26 (+) and 60 ()

CH20 data input

Pins 25 (+) and 59 ()

CH21 data output

Pins 24 (+) and 58 ()

CH21 data input

Pins 23 (+) and 57 ()

CH22 data output

Pins 22 (+) and 56 ()

CH22 data input

Pins 21 (+) and 55 ()

CH23 data output

Pins 20 (+) and 54 ()

CH23 data input

Pins 19 (+) and 53 ()

CH24 data output

Pins 18 (+) and 52 ()

CH24 data input

Pins 17 (+) and 51 ()

CH25 data output

Pins 16 (+) and 50 ()

CH25 data input

Pins 15 (+) and 49 ()

CH26 data output

Pins 14 (+) and 48 ()

CH26 data input

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 INTFC)


Terminal

Description

Pins 13 (+) and 47 ()

CH27 data output

Pins 12 (+) and 46 ()

CH27 data input

Pins 11 (+) and 45 ()

CH28 data output

Pins 10 (+) and 44 ()

CH28 data input

Pins 9 (+) and 43 ()

CH29 data output

Pins 8 (+) and 42 ()

CH29 data input

Pins 7 (+) and 41 ()

CH30 data output

Pins 6 (+) and 40 ()

CH30 data input

Pins 5 (+) and 39 ()

CH31 data output

Pins 4 (+) and 38 ()

CH31 data input

Pins 3 (+) and 37 ()

CH32 data output

Pins 2 (+) and 36 ()

CH32 data input

2-35

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-A
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-36

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH8 data input

Pins 3 (+) and 4 ()

CH7 data input

Pins 6 (+) and 7 ()

CH6 data input

Pins 8 (+) and 9 ()

CH5 data input

Pins 11 (+) and 12 ()

CH4 data input

Pins 13 (+) and 14 ()

CH3 data input

Pins 16 (+) and 17 ()

CH2 data input

Pins 18 (+) and 19 ()

CH1 data input

Pins 20 (+) and 21 ()

CH8 data output

Pins 22 (+) and 23 ()

CH7 data output

Pins 25 (+) and 26 ()

CH6 data output

Pins 27 (+) and 28 ()

CH5 data output

Pins 29 (+) and 30 ()

CH4 data output

Pins 31 (+) and 32 ()

CH3 data output

Pins 34 (+) and 35 ()

CH2 data output

Pins 36 (+) and 37 ()

CH1 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-B
(CH 9 to CH 16)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 9 to CH 16), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH16 data input

Pins 3 (+) and 4 ()

CH15 data input

Pins 6 (+) and 7 ()

CH14 data input

Pins 8 (+) and 9 ()

CH13 data input

Pins 11 (+) and 12 ()

CH12 data input

Pins 13 (+) and 14 ()

CH11 data input

Pins 16 (+) and 17 ()

CH10 data input

Pins 18 (+) and 19 ()

CH9 data input

Pins 20 (+) and 21 ()

CH16 data output

Pins 22 (+) and 23 ()

CH15 data output

Pins 25 (+) and 26 ()

CH14 data output

Pins 27 (+) and 28 ()

CH13 data output

Pins 29 (+) and 30 ()

CH12 data output

Pins 31 (+) and 32 ()

CH11 data output

Pins 34 (+) and 35 ()

CH10 data output

Pins 36 (+) and 37 ()

CH9 data output

2-37

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-A
(CH 17 to CH 24)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 17 to CH 24), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-38

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH24 data input

Pins 3 (+) and 4 ()

CH23 data input

Pins 6 (+) and 7 ()

CH22 data input

Pins 8 (+) and 9 ()

CH21 data input

Pins 11 (+) and 12 ()

CH20 data input

Pins 13 (+) and 14 ()

CH19 data input

Pins 16 (+) and 17 ()

CH18 data input

Pins 18 (+) and 19 ()

CH17 data input

Pins 20 (+) and 21 ()

CH24 data output

Pins 22 (+) and 23 ()

CH23 data output

Pins 25 (+) and 26 ()

CH22 data output

Pins 27 (+) and 28 ()

CH21 data output

Pins 29 (+) and 30 ()

CH20 data output

Pins 31 (+) and 32 ()

CH19 data output

Pins 34 (+) and 35 ()

CH18 data output

Pins 36 (+) and 37 ()

CH17 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (32E1 I/O BOARD)


Terminal

Description

8E1 INTFC
2M IN/OUT-B
(CH 25 to CH 32)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 25 to CH 32), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH32 data input

Pins 3 (+) and 4 ()

CH31 data input

Pins 6 (+) and 7 ()

CH30 data input

Pins 8 (+) and 9 ()

CH29 data input

Pins 11 (+) and 12 ()

CH28 data input

Pins 13 (+) and 14 ()

CH27 data input

Pins 16 (+) and 17 ()

CH26 data input

Pins 18 (+) and 19 ()

CH25 data input

Pins 20 (+) and 21 ()

CH32 data output

Pins 22 (+) and 23 ()

CH31 data output

Pins 25 (+) and 26 ()

CH30 data output

Pins 27 (+) and 28 ()

CH29 data output

Pins 29 (+) and 30 ()

CH28 data output

Pins 31 (+) and 32 ()

CH27 data output

Pins 34 (+) and 35 ()

CH26 data output

Pins 36 (+) and 37 ()

CH25 data output

2-39

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.6 16E1 INTFC (I/O BOARD)


Type A: Standard PKG (e/w LAN)
2M IN/OUT-A

PORT1
PORT2

2M IN/OUT-B

ALM (red)

ALM
2M IN/OUT-B

2M IN/OUT-A

100M

PORT 1

PORT 2

100M

100M(green)
COLLISION/DUPLEX(amber)
LINK(green)

Type B: 2-WAY/XC PKG (e/w LAN)

2-WAY Label
ALM (red)

PORT1
PORT2

2M IN/OUT-B

2M IN/OUT-A

ALM
2M IN/OUT-B

2M IN/OUT-A

100M

Using this type, the 2-WAY/Cross-connect (XC) setting is


available for E1/LAN signals transmission in two different
directions with one IDU and two ODUs.

PORT 1

PORT 2

100M

2-WAY

100M(green)
COLLISION/DUPLEX(amber)
LINK(green)

Caution: Do not insert/extract the 16E1 INTFC with the power ON, turn the IDU power OFF
and remove all cables connected to the 16E1 INTFC before insert/extract the 16E1
INTFC, or 16E1 INTFC may be damaged.
Optional I/O BOARD
Following I/O BOARD provides when the BNC 16E1 interface is required to the 2M IN/OUT INTFC instead of DSub 37 pins.
TRAFFIC IN

TRAFFIC OUT

2M IN/OUT-A

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9

CH10

CH11

CH12

CH13

CH14

CH15

CH16

User Interface

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9

CH10

CH11

CH12

CH13

CH14

CH15

CH16

2M IN/OUT-B

IDU Interface

User Interface

Note: One Unit space is necessary to install I/O BOARD above or below IDU and 2 D-Sub/D-Sub
cables also.
The 16E1 INTFC applies for up to 16E1 (2.048 Mbps) signals interface.
The module performs, Bipolar-Unipolar/Unipolar-Bipolar conversion,
Stuffing/Destuffing, Multiplex/Demultiplex the radio section frame,
Hitless Switching, AIS Detection/Generation and Near End/Far End
loopback for each E1 CH. The interface impedance can be selected from
75 ohms/unbalanced and 120 ohms/balanced using LCT.
2 PORT LAN interface provides optionally to transmit up to 80 Mbps
LAN with/without E1 signals.
The 2-WAY/XC PKG (e/w LAN) type is applicable to transmit E1/LAN
signals in two different directions by using one IDU with two MODEMs
and two ODUs.

2-40

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

The user interface signals conform to ITU-T/IEEE as listed in the


following tables. For details, refer to Appendix LAN INTFC (10/
100BASE-T(X))2-WAY/XC Application and Setting.

Interface Signals (16E1 INTFC)

2M IN/OUT-A/-B
(D-Sub Connector)

8E1 interface in each 2 connectors.

Input/Output Signal:

Up to 16E1 signals without LAN

Bit Rate:

2.048 Mbps +/102.4 bitps

Code:

HDB3

Impedance:

75 ohms unbalanced or 120 ohms balanced *

PORT1/PORT2
(RJ-45) optional

LAN interface port 1 and 2 separated.


8 to 80 Mbps shared when 16E1 to 0E1 are used.

Input/Output Signal:

10/100BASE-T(X) Auto-sensing or fixed

Flow control:

Full duplex or Half duplex

Forwarding mode:

Store-and-Forwarding
Note: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.
Indicators (16E1 INTFC)

LED

ALM

Indication

Remarks

LOS from DTE is detected.

Check DTE and wiring.

Loss of output signal to DTE is detected.

Perform Far End loopback test.

Error of channel usage.

Signal is applied to unused channel.

Mounting module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

LAN link failure occurs.

Check LAN cable connection.

100M

LAN signal is in 100BASE-TX mode.

LINK

LAN and associated equipment are linked


and flashing under the exchanging the
packet.

COLLISION/
DUPLEX

Input/Output LAN signal is in Full


Duplex mode. Flashing when a collision
condition occurs.

2-41

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (16E1 INTFC)


Terminal

Description

16E1 INTFC
2M IN/OUT-A
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)
(I/O BOARD IDU INTFC)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

2-42

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH8 data input

Pins 3 (+) and 4 ()

CH7 data input

Pins 6 (+) and 7 ()

CH6 data input

Pins 8 (+) and 9 ()

CH5 data input

Pins 11 (+) and 12 ()

CH4 data input

Pins 13 (+) and 14 ()

CH3 data input

Pins 16 (+) and 17 ()

CH2 data input

Pins 18 (+) and 19 ()

CH1 data input

Pins 20 (+) and 21 ()

CH8 data output

Pins 22 (+) and 23 ()

CH7 data output

Pins 25 (+) and 26 ()

CH6 data output

Pins 27 (+) and 28 ()

CH5 data output

Pins 29 (+) and 30 ()

CH4 data output

Pins 31 (+) and 32 ()

CH3 data output

Pins 34 (+) and 35 ()

CH2 data output

Pins 36 (+) and 37 ()

CH1 data output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (16E1 INTFC)


Terminal

Description

16E1 INTFC
2M IN/OUT-B
(CH 9 to CH 16)
(D-Sub Connector, 37 pins)
(I/O BOARD IDU INTFC)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 9 to CH 16), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH16 data input

Pins 3 (+) and 4 ()

CH15 data input

Pins 6 (+) and 7 ()

CH14 data input

Pins 8 (+) and 9 ()

CH13 data input

Pins 11 (+) and 12 ()

CH12 data input

Pins 13 (+) and 14 ()

CH11 data input

Pins 16 (+) and 17 ()

CH10 data input

Pins 18 (+) and 19 ()

CH9 data input

Pins 20 (+) and 21 ()

CH16 data output

Pins 22 (+) and 23 ()

CH15 data output

Pins 25 (+) and 26 ()

CH14 data output

Pins 27 (+) and 28 ()

CH13 data output

Pins 29 (+) and 30 ()

CH12 data output

Pins 31 (+) and 32 ()

CH11 data output

Pins 34 (+) and 35 ()

CH 10 data output

Pins 36 (+) and 37 ()

CH 9 data output

2-43

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (16E1 INTFC)


Terminal

Description

LAN PORT1/PORT2
(RJ-45, 8 pins)

LAN PORT, optional

Pin 1

LAN TD+/LAN RD+

Pin 2

LAN TD/LAN RD

Pin 3

LAN RD+/LAN TD+

Pins 4 and 5

Not Connected

Pin 6

LAN RD/LAN TD

Pin 7 and 8

Not Connected

Note: Do not connect any cable to the Not Connected pins.

2-44

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.7 STM-1 INTFC


STM-1 (ELE) INTFC
STM-1 IN

STM-1 OUT

ALM
STM-1 IN

STM-1 (OPT) INTFC

STM-1 OUT

STM-1 OUT

ALM (red)

STM-1 IN

ALM
STM-1 OUT

STM-1 IN

ONLINE
ALM (red)
ONLINE(green)

Caution: Do not insert/extract the STM-1 INTFC with the power ON, turn OFF the PWR
switch on the MODEM and remove all cables connected to the STM-1 INTFC before
insert/extract the STM-1 INTFC, or STM-1 INTFC may be damaged.
The STM-1 INTFC provides STM-1 signal interface with two types, one is
electrical and the other is optical. The module performs,
- Coded Mark Inversion (CMI) to Non Return to Zero (NRZ)
conversion
- Optical to Electrical conversion *
- RSOH termination
- Stuffing control
- Hitless switching (for 1+1 configuration)
- Performance monitoring (conforms to G.826/G.828)
- Automatic Laser Shut Down (ALS)*
- Near End/Far End loopback
Note: *: For the Optical INTFC only.

2-45

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Interface Signals (STM-1 INTFC)

STM-1 IN/OUT
IEC 169-29 (1.0/2.3)

Electrical STM-1 Input/Output, G.703

STM-1 IN/OUT
LC

Optical STM-1 Input/Output, G.957

Input/Output Signal:
Electrical
Type:

G.703

Bit Rate:

155.520 Mbps

Level:

1 Vp-p (nominal)

Code:

CMI

Impedance:

75 ohms unbalanced

Optical
Type:

G.957

Bit Rate:

155.520 Mbps

Level:

L-1.1: 0 to 8 dBm (TX)/10 to 34 dBm (RX)


S-1.1: 8 to 15 dBm (TX)/8 to 28 dBm (RX)

Code:

NRZ

Wavelength:

1310 nm

2-46

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (STM-1 INTFC)


LED

Indication

Remarks

LOS of STM-1 from MUX is detected.

Check MUX and wiring.

Frame synchronization of input STM-1 signal


from MUX is los (Electrical INTFC).

Check MUX and wiring.

BER (E-BER, DMR or MUX) is worse than


preset value (10-3 to 10-5, selectable).
ALM

ONLINE

BER (SD, DMR or MUX) is worse than preset


value (10-5 to 10-9, selectable).

Check RSL, Interference and TX


power at opposite site when BER
ALM occurs.

Frame synchronization of input STM-1 signal


from radio is lost.

Check STM-1 transmission at the


opposite site, ODU or MODEM in
local.

Mounting module
inventory.

Change LCT setting or other


( )INTFC module.

is

not

matched

with

Online status of Working/Standby in APS: ON


Offline status of Working/Standby in APS: OFF
Online status of Working w/o APS: ON

2-47

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.8 E3 INTFC
E3 CH1 OUT
E3 CH1 IN

WS IN/OUT

E3 CH2 IN
E3 CH2 OUT

ALM (red)

PORT1
PORT2

E3 CH2

E3 CH1

ALM
IN

OUT

IN

WS IN/OUT

OUT

100M

PORT 1

PORT 2

100M

100M(green)
COLLISION/DUPLEX(amber)
LINK(green)

Caution: Do not insert/extract the E3 INTFC with the power ON, turn the IDU power OFF and
remove all cables connected to the E3 INTFC before insert/extract the E3 INTFC, or
E3 INTFC may be damaged.
The E3 INTFC applies for up to two (2) E3 (34.368 Mbps) signals, four (4)
or eight (8) WS (2.048 Mbps) signals and two (2) port LAN (10/
100BASE-T(X)) signals interface. The module performs, BipolarUnipolar/Unipolar-Bipolar conversion, Stuffing/Destuffing, Multiplex/
Demultiplex the radio section frame, Hitless Switching and AIS Detection/
Generation for each E3 and WS (E1) signal. The interface impedance of
the WS can be selected from 75 ohms/unbalanced and 120 ohms/balanced
using LCT.
2 PORT LAN interface provides optionally to transmit up to 16 Mbps
LAN signal using WS (E1)/SC signal band.
The user interface signals conform to ITU-T/IEEE as listed in the
following tables.
User Interface Signals (E3 INTFC)

E3 CH1/CH2 IN/OUT
(IEC 169-29 (1.0/2.3)

2 E3 interface in each 2 ports.

Input/Output Signal:

E3 signal

Bit Rate:

34.368 Mbps +/688 bitps

Code:

HDB3

Impedance:

75 ohms unbalanced

LAN PORT1/PORT2
(RJ-45) optional

LAN interface Port 1 and Port 2 shared.


Selectable 2 to 16 Mbps (for 2E3) shared depending to
WS (1E1 to 8E1) CHs are assigned for LAN.
Selectable 64/128/256 kbps shared depending to SC (SC1
to SC4) CHs are assigned for LAN.

Input/Output Signal:

10/100BASE-T(X) Auto-sensing or fixed

Flow control:

Full duplex or Half duplex

Forwarding mode:

Store-and-Forwarding

2-48

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (E3 INTFC)


LED

ALM

Indication

Remarks

LOS from DTE is detected.

Check DTE and wiring.

Loss of output signal to DTE is detected.

Perform Far End loopback test.

Mounting module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

LAN link failure occurs.

Check LAN cable connection.

100M

LAN signal is in 100BASE-TX mode.

LINK

LAN and associated equipment are linked


and flashing under the exchanging the
packet.

COLLISION/
DUPLEX

Input/Output LAN signal is in Full


Duplex mode. Flashing when a collision
condition occurs.

2-49

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (E3 INTFC)


Terminal

Description

WS INTFC
WS IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal
through interface cable when unbalanced impedance
is used.
The (+) and () pin connections should be connected
to a signal twisted pair cable, otherwise, signal
quality may be degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH8 data input

Pins 3 (+) and 4 ()

CH7 data input

Pins 6 (+) and 7 ()

CH6 data input

Pins 8 (+) and 9 ()

CH5 data input

Pins 11 (+) and 12 ()

CH4 data input

Pins 13 (+) and 14 ()

CH3 data input

Pins 16 (+) and 17 ()

CH2 data input

Pins 18 (+) and 19 ()

CH1 data input

Pins 20 (+) and 21 ()

CH8 data output

Pins 22 (+) and 23 ()

CH7 data output

Pins 25 (+) and 26 ()

CH6 data output

Pins 27 (+) and 28 ()

CH5 data output

Pins 29 (+) and 30 ()

CH4 data output

Pins 31 (+) and 32 ()

CH3 data output

Pins 34 (+) and 35 ()

CH2 data output

Pins 36 (+) and 37 ()

CH1 data output

Note: For unbalanced impedance, ground level is applied from


associated equipment through interface cable.

2-50

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (E3 INTFC)


Terminal

LAN PORT1/PORT2
(RJ-45, 8 pins)

Description

LAN PORT

Pin 1

LAN TD+/LAN RD+

Pin 2

LAN TD/LAN RD

Pin 3

LAN RD+/LAN TD+

Pins 4 and 5

Not Connected

Pin 6

LAN RD/LAN TD

Pin 7 and 8

Not Connected

Note: Do not connect any cable to the Not Connected pins

2-51

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.9 LAN/WS INTFC (Optional)


LAN/WS INTFC

PORT1
PORT2

PORT 1

PORT 2

Type A

PORT 1

Type B

ALM LED (red)

ALM LED (red)

WS IN/OUT
ALM

WS
100M

WS IN/OUT

WS IN/OUT

100M

PORT1
PORT2

ALM

ALM

WS
100M

WS IN/OUT

WS IN/OUT

PORT 2

WS IN/OUT

100M

Type C

M.S

ALM LED (red)

Function
Type

Remarks
Main LAN *1

Sub LAN *2

E1 WS*2

Exclusive Sub CH for WS/LAN

Exclusive Sub CH for WS

Either Slot for Main or Sub CH for WS/LAN

: Unavailable
: Available

*1 :
*2:

Main: w/o STM-1


Sub: e/w STM-1
Mounting position is Slot1 (for Main).
Mounting position is Slot2 (for Sub).

The LAN/WS INTFC (optional) provides 2 Port LAN interface (for Type
A/C) and 1 WS (E1) interface. The LAN/WS INTFC provides a function
of WS AIS Detection/Generation. The interface impedance of the WS can
be selected from 75 ohms/unbalanced and 120 ohms/balanced using LCT.
The LAN/WS INTFC is installed into the Sub-INTFC Slot2 (for Type A/
B) or Slot1 (for Type C) in the SDH system configuration. The LAN
interface functions for each type are listed in following table.

2-52

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Signals (LAN/WS INTFC)

WS IN/OUT
(D-Sub Connector)

WS (1 E1) interface.

Input/Output Signal:

2.048 Mbps +/102.4 bits, HDB3 coded data input/output


from/to DTE, 75/120 ohms (selectable).

Type A/C
in Slot 2

LAN PORT1/PORT2
(RJ-45, 8 pins)

10/100BASE-T(X)
LAN interface Port 1 and Port 2 shared.
RX switching is performed through Hit SW by High BER
ALM.
LAN signal is transmitted via RFCOH.
Selectable 2 Mbps depending to WS (E1) CH is assigned
for LAN.
Selectable 64/128/192/256 kbps or 2 MB depending to
SC (SC1 to SC4)/WS CHs are assigned for LAN.

Type C
in Slot 1

LAN PORT1/PORT2
(RJ-45, 8 pins)

10/100BASE-T(X).
LAN interface Port 1 and Port 2 separated (75/75MB,
100/50 MB, Best Effort selectable).
RX switching is performed through Hitless SW.
LAN signal mapping takes place in the STM-1.
RSOH bytes (E1/F1/DCCr) are available.
RMON is available.
Maximum throughput packet size is 1548 bytes.

Type A/C

Input/Output Signal:

10/100BASE-T(X) Auto-sensing or fixed

Type A/B/C

Flow control:

Full duplex or Half duplex

Forwarding mode:

Store-and-Forwarding

2-53

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (LAN/WS INTFC)


Terminal

LAN PORT1/PORT2
(RJ-45, 8 pins)

Description

LAN PORT

Pin 1

LAN TD+/LAN RD+

Pin 2

LAN TD/LAN RD

Pin 3

LAN RD+/LAN TD+

Pins 4 and 5

Not Connected

Pin 6

LAN RD/LAN TD

Pin 7 and 8

Not Connected

Note: Do not connect any cable to the Not Connected pins


WS INTFC
WS IN/OUT
(CH 1)
(D-Sub Connector, 9 pins)
Pins 2, 4, 5, 7 and 9

Ground

Pins 1 (+) and 6 ()

WS CH1 data input

Pins 3 (+) and 8 ()

WS CH1 data output

Note: () is applied to Ground for 75-ohms unbalanced interface.


The (+) and () pin connections should be connected to a signal twisted pair cable,
otherwise, signal quality may be degraded.

2-54

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (LAN/WS INTFC)


LED

Indication

Remarks

100M

LAN signal is in 100BASE-TX mode.

LINK

LAN and associated equipment are linked


and flashing under the exchanging the
packet.

COLLISION/
DUPLEX

Input/Output LAN signal is in Full


Duplex mode. Flashing when a collision
condition occurs.

WS

Lights when WS is using.

For Type A/C

LOS from WS DTE is detected.

Check WS DTE and wiring.

Mounted module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

LAN link failure occurs. (For Type A/C)

Check LAN cable connection.

Module failure occurs.

Replace the module with a spare.

ALM

2-55

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.10 4P LAN INTFC (Optional)


4P LAN INTFC

PORT1
PORT2

ALM
LED(red)

PORT3
PORT4

ALM

2M IN/OUT
100M

PORT 1

PORT 2

100M

100M

PORT 3

PORT4

100M

4P LAN INTFC

The 4P LAN INTFC (optional) is installed into the Main-INTFC slot


(Slot1) in the PDH system configuration and it provides 4 Port LAN
interface with up to 8E1 interfaces. The LAN interface is used 4 Port
shared (P1-P4) mode, 2 Port (P1-P2/P3-P4) shared mode or separated (P1/
P2/P3/P4) mode. It is possible to use 4 Port LAN interfaces in
transmission capacity of 100 Mbps (32QAM) as special mode (applicable
channel number of E1 are 4 CH in this mode). When the transmission
capacity is used within 10 to 80 Mbps, the occupied band width for the
LAN and E1 is assignable as the same assignement as the 16E1 INTFC.
The E1 interface impedance of the 2M IN/OUT can be selected from 75
ohms/unbalanced and 120 ohms/balanced using LCT.
When this module is applied, use of SC channel is unavailable.
The LAN Port switching function is selectable when the LAN Port Usage
is applied to the Shared Mode.
Separated

P1-P4 Shared
(3) Dir-A

(4) Dir-A

(5) Dir-A

P1 P2 P3 P4

2-56

P1 P2 P3 P4

P1 P2 P3 P4

P1 P2 P3 P4

Enabled

Switching

Disabled

(1) Dir-A

P1-P2 Shared
P3-P4 Shared
(2) Dir-A

P1 P2 P3 P4

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Signals (4P LAN INTFC)

LAN
PORT1
PORT4 (RJ-45)

to

Input/Output Signal:

LAN interface Port 1, Port 2, Port 3 and Port 4.


Selectable 2 Mbps to 100 Mbps depending to E1 CH is
assigned for LAN.
10/100BASE-T(X) Auto-sensing or fixed

Flow control:

Full duplex or Half duplex

Forwarding mode:

Store-and-Forwarding

2M IN/OUT
(D-Sub Connector)

8E1 interface.

Input/Output Signal:

up to 8E1 signals without LAN

Bit Rate:

2.048 Mbps +/102.4 bitps

Code:

HDB3

Impedance:

75 ohms unbalanced or 120 ohms balanced *


Note: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.
User Interface Pin Assignment (4P LAN INTFC)

Terminal

Description

LAN PORT1/PORT2
(RJ-45, 8 pins)

LAN PORT

Pin 1

LAN TD+/LAN RD+

Pin 2

LAN TD/LAN RD

Pin 3

LAN RD+/LAN TD+

Pins 4 and 5

Not Connected

Pin 6

LAN RD/LAN TD

Pin 7 and 8

Not Connected

Note: Do not connect any cable to the Not Connected pins

2-57

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (4P LAN INTFC)


Terminal

2M IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37 pins)

Description

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal through
interface cable when unbalanced impedance is used.
The (+) and () pin connections should be connected to a
signal twisted pair cable, otherwise, signal quality may be
degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH8 data input

Pins 3 (+) and 4 ()

CH7 data input

Pins 6 (+) and 7 ()

CH6 data input

Pins 8 (+) and 9 ()

CH5 data input

Pins 11 (+) and 12 ()

CH4 data input

Pins 13 (+) and 14 ()

CH3 data input

Pins 16 (+) and 17 ()

CH2 data input

Pins 18 (+) and 19 ()

CH1 data input

Pins 20 (+) and 21 ()

CH8 data output

Pins 22 (+) and 23 ()

CH7 data output

Pins 25 (+) and 26 ()

CH6 data output

Pins 27 (+) and 28 ()

CH5 data output

Pins 29 (+) and 30 ()

CH4 data output

Pins 31 (+) and 32 ()

CH3 data output

Pins 34 (+) and 35 ()

CH2 data output

Pins 36 (+) and 37 ()

CH1 data output

2-58

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (4P LAN INTFC)


LED

Indication

100M

LAN signal is in 100BASE-TX mode.

LINK

LAN and associated equipment are linked


and flashing under the exchanging the
packet.

COLLISION/
DUPLEX

Input/Output LAN signal is in Full


Duplex mode. Flashing when a collision
condition occurs.

ALM

Remarks

E1 LOS from DTE is detected.

Check DTE and wiring.

Mounting module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

E1 Usage error occurs.

Check E1 cable connection and E1


CH assignment.

LAN link failure occurs.

Check LAN cable connection.

Module failure occurs.

Replace the module with a spare.

2-59

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.11 GbE INTFC (Optional)


1000BASE-SX/LX

1000BASE-T

Indicator

OPT
ALM
OUT

IN

PORT

The GbE INTFC (optional) provides 1000BASE-SX/LX and 1000BASET interface. The GbE INTFC is installed into the Main-INTFC slot (Slot1)
instead of the STM-1 INTFC in the SDH (128QAM) system
configuration. The signal is connected either SFP (for 1000BASE-SX/LX)
or RJ-45 (for 1000BASE-T).
The LAN signal is transferred to STM-1 signal by data mapping using
unique method to improve throughput. The RSOH bytes (E1/F1/DCCr) is
available between radio links. The RMON for LINE side is available but
DMR side is unavailable. The maximum passage packet size is 9600 bytes.
The GbE INTFC is applicable together with the LAN/WS INTFC.

2-60

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Signals (GbE INTFC)

1000BASE-SX/LX:*

Gigabit Ether signal, Optical Interface

1000BASE-SX:

Multimode Fiber/LC Connector

1000BASE-LX:

Single/Multimode Fiber/LC Connector

(SFP Fiber Connector)


IN (Right Side):
OUT (Left Side):

1000BASE-SX/LX Input
1000BASE-SX/LX Output

Type:

H3021A: 1000BASE-SX
H3021C: 1000BASE-LX

Speed & Duplex:

1000 Mbits Full Duplex/Auto Negotiation fixed

Flow control:

Flow control ON or OFF selectable

Link
Forwarding:

Loss

Disabled/Enabled selectable

1000BASE-T:

Gigabit Ether signal, Electrical Interface

1000BASE-T Port:
(RJ-45
Interface
Connector)

Ether signal Input/Output

Speed & Duplex:

1000 Mbits Full Duplex/Auto Negotiation fixed

Flow control:

Flow control ON or OFF selectable

Link
Forwarding:

Loss

Disabled/Enabled selectable

*Maximum Optical Cable length:


1000BASE-SX(850 nm): Multimode fiber (275 m (core dia.62.5 m), 550 m (core dia.50 m))
1000BASE-LX(1300 nm): Multimode fiber (550 m (core dia.62.5 m), 550 m (core dia.50 m))
Single mode fiber (5000 m)
For H3021A, C GbE INTFC, 10/100BASE-T(X) is not supported.

2-61

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (GbE INTFC)


Terminal

Description

1000BASE-SX

Multimode Fiber/LC Connector

1000BASE-LX

Single/Multimode Fiber/LC Connector

IN (Right side)

1000BASE-SX/LX Input

OUT (Left side)

1000BASE-SX/LX Output

1000BASE-T
(RJ-45, 8 pins)

1000BASE-T Input/Output
(MDI/MDI-X)

Pin 1

DATA-A+/DATA-B+

Pin 2

DATA-A/DATA-B

Pin 3

DATA-B+/DATA-A+

Pin 4

DATA-C+/DATA-D+

Pin 5

DATA-C/DATA-D

Pin 6

DATA-B/DATA-A+

Pin 7

DATA-D+/DATA-C+

Pin 8

DATA-D/DATA-C

Note: Cable connector: CAT5e/RJ-45

2-62

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (GbE INTFC)


LED

Indicator

Indication

Remarks

Indicates which Port is applied to the


signal interface.
When the indicator is flashing slowly,
the input signal is off in the
corresponding interface port which is
set to be used.
When the indicator is flashing fast, the
input/output signal is on in the
corresponding interface port which is
set to be used.
When the indicator is lit steady, the
signal is linked in the corresponding
interface port which is set to be used.
When the indicator is unlit, the
corresponding interface which port is
set to no use.

ALM

Mounting module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

Module failure occurs.

Replace the module with a spare.

LOS from DMR is detected.


LOF from DMR is detected.
Excessive-BER alarm condition from
DMR occurs.

Check IDU/ODU and radio link.

SD from DMR is detected.


GbE output signal for fiber cable is
interrupted.

Replace the module with a spare. (SFP


mode only)

LAN link failure occurs.

Check LAN cable connection.

2-63

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.12 4P LAN INTFC-E (Optional)

This module provides 8E1 channels and four ports 10BASE-T/100BASETX interfaces. By using VLAN configuration, one signal capacity can be
share among four LAN ports. LAN throughput maximum bandwidth can
be set from 2 Mbps to 100 Mbps.
When this module is applied, use of SC channel is unavailable.
The LAN Port switching function is selectable as LAN Port Usage
is Shared Mode.

User Interface Signals (4P LAN INTFC-E)

LAN
PORT1
PORT4 (RJ-45)

to

Input/Output Signal:

LAN interface Port 1, Port 2, Port 3 and Port 4.


Selectable 2 Mbps to 100 Mbps depending to E1 CH
is assigned for LAN.
10/100BASE-T(X) Auto-sensing or fixed

Flow control:

Full duplex or Half duplex

Forwarding mode:

Store-and-Forwarding

2M IN/OUT
(D-Sub Connector)

8E1 interface.

Input/Output Signal:

up to 8E1 signals without LAN

Bit Rate:

2.048 Mbps +/102.4 bitps

Code:

HDB3

Impedance:

75 ohms unbalanced or 120 ohms balanced *


Note: *: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.

2-64

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assigment (4P LAN INTFC-E)


Terminal

Description

LAN PORT1 to PORT4


(RJ-45,8 pins)

LAN PORT

Pin 1

LAN TD+/LAN RD+

Pin 2

LAN TD/LAN RD

Pin 3

LAN RD+/LAN TD+

Pins 4 and 5

Not Connected

Pin 6

LAN RD/LAN TD

Pin 7 and 8

Not Connected

Note: Do not connect any cable to the Not Connected pins


2M IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37
pins)

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal through
interface cable when unbalanced impedance is used.
The (+) and () pin connections should be connected to a
signal twisted pair cable, otherwise, signal quality may be
degraded.

2-65

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (4P LAN INTFC-E)


Terminal

2M IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37
pins)

Description

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal through
interface cable when unbalanced impedance is used.
The (+) and () pin connections should be connected to a
signal twisted pair cable, otherwise, signal quality may be
degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

CH8 data input

Pins 3 (+) and 4 ()

CH7 data input

Pins 6 (+) and 7 ()

CH6 data input

Pins 8 (+) and 9 ()

CH5 data input

Pins 11 (+) and 12 ()

CH4 data input

Pins 13 (+) and 14 ()

CH3 data input

Pins 16 (+) and 17 ()

CH2 data input

Pins 18 (+) and 19 ()

CH1 data input

Pins 20 (+) and 21 ()

CH8 data output

Pins 22 (+) and 23 ()

CH7 data output

Pins 25 (+) and 26 ()

CH6 data output

Pins 27 (+) and 28 ()

CH5 data output

Pins 29 (+) and 30 ()

CH4 data output

Pins 31 (+) and 32 ()

CH3 data output

Pins 34 (+) and 35 ()

CH2 data output

Pins 36 (+) and 37 ()

CH1 data output

2-66

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (4P LAN INTFC-E)


LED

Indication

100M

LAN signal is in 100BASE-TX mode.

LINK

LAN and associated equipment are


linked and flashing under the
exchanging the packet.

COLLISIO
N/
DUPLEX

Input/Output LAN signal is in Full


Duplex mode. Flashing when a
collision condition occurs.

ALM

Remarks

E1 LOS from DTE is detected.

Check DTE and wiring.

Mounted module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

E1 Usage error occurs.

Check E1 cable connection and E1 CH


assignment.

LAN link failure occurs.

Check LAN cable connection.

Module failure occurs.

Replace the module with a spare.

2-67

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.13 Gbe INTFC-E (Optional)

2.13.1 Port 1 (GbE Usage)


This module provides one GbE interface, three ports 10BASE-T/
100BASE/TX interfaces and one channel for WS interface (E1). All these
channels are transmitted over the payload of SDH (STM-1).
User Interface Signals (GbE INTFC-E/Port 1)

1000BASE-SX/LX:

Gigabit Ether signal, Optical Interface

1000BASE-SX:*

Multimode Fiber/LC Connector

1000BASE-LX:*

Single/Multimode Fiber/LC Connector

(SFP Fiber Connector)


IN (Right Side):
OUT (Left Side):

1000BASE-SX/LX Input
1000BASE-SX/LX Output

Type:

H3022B 1000BASE-SX
H3022C 1000BACE-LX

Speed & Duplex:

1000Mbits Full Duplex/Auto Negotiation fixed

Flow control:

Flow control ON or OFF selectable

Link Loss
Forwarding:

Disabled/Enabled selectable
* For GbE INTFC-E, this function supports as Link Down Control

1000BASE-T:

Gigabit Ether signal, Electrical Interface

1000BASE-T Port:
(RJ-45
Interface
Connector)

Ether signal Input/Output

Speed & Duplex:

10/100BASE-T(X)/1000BASE-T Auto -sensing or fixed

Flow control:

Flow control ON or OFF selectable

Link Loss
Forwarding:

Disabled/Enabled selectable

*Maximum Optical Cable length:


1000BASE-SX(850nm): Multimode fiber (275m (core dia.62.5m), 550m (core dia.50m))
1000BASE-LX(1300nm): Multimode fiber (550m (core dia.62.5m), 550m (core dia.50m))
Single mode fiber (5000m)

2-68

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (GbE INTFC-E/Port1)


Terminal

Description

1000BASE-SX

Multimode Fiber/LC Connector

1000BASE-LX

Single/Multimode Fiber/LC Connector

IN (Right side)

1000BASE-SX/LX Input

OUT (Left side)

1000BASE-SX/LX Output

1000BASE-T
(RJ-45, 8 pins)

1000BASE-T Input/Output
(MDI/MDI-X)

Pin 1

DATA-A+/DATA-B+

Pin 2

DATA-A/DATA-B

Pin 3

DATA-B+/DATA-A+

Pin 4

DATA-C+/DATA-D+

Pin 5

DATA-C/DATA-D

Pin 6

DATA-B/DATA-A+

Pin 7

DATA-D+/DATA-C+

Pin 8

DATA-D/DATA-C

Note: Cable connector: CAT5e/RJ-45

2-69

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (GbE INTFC-E/Port 1)


LED

Indicator

Indication

Remarks

Indicates which Port is applied to the


signal interface.
When the indicator is flashing slowly,
the input signal is off in the
corresponding interface port which is set
to be used.
When the indicator is flashing fast, the
input/output signal is on in the
corresponding interface port which is set
to be used.
When the indicator is lit steady, the
signal is linked in the corresponding
interface port which is set to be used.
When the indicator is unlit, the
corresponding interface which port is set
to no use.

ALM

Mounted module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

Module failure occurs.

Replace the module with a spare.

LOS from DMR is detected.


LOF from DMR is detected.
Excessive-BER alarm condition from
DMR occurs.

Check IDU/ODU and radio link.

SD from DMR is detected.

2-70

GbE output signal for fiber cable is


interrupted.

Replace the module with a spare. (SFP


mode only)

LAN link failure occurs.

Check LAN cable connection.

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.13.2 Port 2-4 (10/100BASE-T Usage)


User Interface Signals (LAN INTFC/Port 2-4)

LAN PORT2 to
PORT4 (RJ-45)

All these channels are transmitted over the payload of SDH (STM-1).

Input/Output Signal:

10/100BASE-T(X) Auto-sensing or fixed

Flow control:

Full duplex or Half duplex

Forwarding mode:

Store-and-Forwarding

WS IN/OUT
(D-Sub Connector)

WS(1xE1) interface.

Input/Output Signal:

2.048 Mbps, HDB3 coded data input/output from/to DTE, 75/120 ohms
(selectable).

Bit Rate:

2.048 Mbps +/102.4 bitps

Code:

HDB3

Impedance:

75 ohms unbalanced or 120 ohms balanced *


Note: *: For unbalanced impedance, ground level is applied from
associated equipment through interface cable.
User Interface Pin Assignment (LAN INTFC/Port 2-4)

Terminal

Description

LAN PORT2 to PORT4


(RJ-45, 8 pins)

LAN PORT

Pin 1

LAN TD+/LAN RD+

Pin 2

LAN TD/LAN RD

Pin 3

LAN RD+/LAN TD+

Pins 4 and 5

Not Connected

Pin 6

LAN RD/LAN TD

Pin 7 and 8

Not Connected

Note: Do not connect any cable to the Not Connected pins

2-71

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

User Interface Pin Assignment (LAN INTFC/Port 2-4)


Terminal

2M IN/OUT
(CH 1 to CH 8)
(D-Sub Connector, 37
pins)

Description

2.048 Mbps HDB3 coded data input/output from/to DTE


(CH 1 to CH 8), 75/120 ohms (selectable)
Note: Ground level is applied from DTE to () terminal through
interface cable when unbalanced impedance is used.
The (+) and () pin connections should be connected to a
signal twisted pair cable, otherwise, signal quality may be
degraded.

Pins 5, 10, 15, 24 and 33

Ground

Pins 1 (+) and 2 ()

Pins 3 (+) and 4 ()

Pins 6 (+) and 7 ()

Pins 8 (+) and 9 ()

Pins 11 (+) and 12 ()

Pins 13 (+) and 14 ()

Pins 16 (+) and 17 ()

Pins 18 (+) and 19 ()

CH1 data input

Pins 20 (+) and 21 ()

Pins 22 (+) and 23 ()

Pins 25 (+) and 26 ()

Pins 27 (+) and 28 ()

Pins 29 (+) and 30 ()

Pins 31 (+) and 32 ()

Pins 34 (+) and 35 ()

Pins 36 (+) and 37 ()

CH1 data output

2-72

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (GbE INTFC-E/Port 2-4)


LED

Indication

100M

LAN signal is in 100BASE-TX mode.

LINK

LAN and associated equipment are


linked and flashing under the exchanging
the packet.

COLLISION/
DUPLEX

Input/Output LAN signal is in Full


Duplex mode. Flashing when a collision
condition occurs.

ALM

Remarks

WS(E1) LOS from DTE is detected.

Check DTE and wiring.

Mounting module is not matched with


inventory.

Change LCT setting or other ( )INTFC


module.

LAN link failure occurs.

Check LAN cable connection.

Module failure occurs.

Replace the module with a spare.

2-73

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

2.14

ROI-S05749

DC-DC CONV (Optional)

DC-DC CONV
43V

STD

FG(Frame Ground)

ALM

43V

PWR

G
OUT

ALM
OUT

FUSE (250V/8AH)

SELV

PWR LED(green)
FUSE (250V/8AH)

PULL
PWR

PWR
SELV

Note: If the PWR LED is not lit though the PWR switch has set to ON, set the PWR switch to
OFF, remove two fuses from the module and check the conduction of them.
Caution: Do not apply to the equipment a voltage that varies sharply. The equipment may
operate wrongly.
Caution: Do not remove/connect the power supply cable with the PWR switch ON, Turn the
PWR switch OFF before connecting/disconnecting the power supply cable IN or
OUT, if not, module may be damaged.
The DC-DC CONV (optional) converts 20 to 60 V or 20 to 60 V DC
input to 43 V stable DC voltage. The module applies when the
PASOLINK+ ODU is connected to the IDU NEO.
Interface Signals (DC-DC CONV)

SELV
(Molex M5569-04A1, 4 pins) (DC IN)
Input Voltage:

20 to 60 V/+20 to +60 V DC

43V OUT
(Molex M5569-02A1, 2 pins) (DC OUT)
Output:
FG (Screw):

43 V/1.3A
Frame Ground terminal
(5 mm square cable (more than 2.5 mm diameter cable)
(AWG#10) is recommended to apply for the frame
ground. The proper press fix terminal tool shall be
used.)

ALM:

2-74

Power supply ALM signal output

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Indicators (DC-DC CONV)


LED

Indication

PWR

Remarks

The PWR switch of the DC-DC CONV is


turned on.

Switches (DC-DC CONV)


Switch

Operating

PWR

IDU and ODU power on/off switch.

Remarks

Refer to Start-up and Shut-down the


Equipment in Maintenance Section

User Interface Pin Assignment (DC-DC CONV)


Terminal

Description

SELV
SELV (DC IN)
(Molex M5569-04A1 Connector,
4 Pins)

20 to 60/20 to 60 V DC power input

Pins 1 and 3

0 V/(or +20 to +60 V)

Pins 2 and 4

20 to 60 V/(or 0 V)

43V OUT
(Molex M5569-02A1,
2 pins) (DC OUT)

43 V DC power output (connects to the SELV connector of


the MODEM module using accessory cable)

Pin 1

Ground

Pin 2

43 V
Power supply ALM signal output

ALM
(D-Sub Female, 9 pins)
Pins 6 (COM), 1 (NC) and
2 (NO)

PS and input voltage alarm output


Between
Pins 1 and 6
Normal state
:
Closed
Alarm state
:
Open

Pin 9

Ground

Pins3,4,5,7,8

No connected

Between
Pins 6 and 2
Open
Closed

2-75

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

2.15 ODU

RF IN/OUT

RX LEV
MON

IFL

FG

(Front View)

(Rear View)

FG (Frame Ground)
RX LEV MON

Antenna Direct Mounting Type

IFL (IF IN/OUT)

RF IN/OUT

RF IN/OUT

(Rear View)

Coaxial Cable Type (6/7/8 GHz)

(Rear View)

WG Type (11 GHz)

6-38 GHz ODU NHG/6-11 GHz ODU NHG2/52 GHz ODU Mx Type

2-76

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

RF IN/OUT

-48V
IFL

RX LEV MON

(Rear View)

(Front View)

RX LEV MON

FG (Frame Ground)

IFL (IF IN/OUT)

(Bottom View)

13-38 GHz ODU NHG2 Type

The ODU receives 340 MHz IF signal from the IDU and converts it to an
RF signal using a local signal generated by a synthesized local oscillator.
This RF signal is then sent to the antenna through the BPF which limits the
RF transmit signal dispersion. The TX output level is controlled to the
specified from the IDU corresponded to the QPSK/16QAM/32QAM or
128QAM modulation.
The RF signal received from the antenna is amplified to the required level.
Afterward the signal is converted into the 140 MHz IF signal by mixing
with a local signal generated by a synthesized local oscillator. Then the
140 MHz IF signal is sent to the IDU through the IF cable.

2-77

Submission Prohibited
NEC Internal Use Only
OPERATING EQUIPMENT

ROI-S05749

Interface Signals (ODU)

IFL (N Female)
TX Frequency

340 MHz

RX Frequency:

140 MHz

Power supply:

48 V

Impedance:

50 ohms
Connecting IF Cable length:
5D-FB: less than 150 m
8D-FB: less than 300 m

FG (Screw)
RF IN/OUT

Frame ground, connecting near by ground point.


RF signal interface.
-

N female connector for the 6/7/8 GHz ODU with coaxial


cable connection.
NEC proprietary flange for the 10 to 52 GHz ODU with
antenna mounting (direct/OMT/HYB COMB/TX ATT).
Waveguide connection flange;
6 GHz:
PDR70
7/8 GHz:
PDR84
10/11 GHz: PDR100
13 GHz:
PBR120 or PBR140
15 GHz:
PBR140
18/23 GHz: PBR220
26 GHz:
PBR260
28/32/38 GHz:PBR320
52 GHz:
WRJ 500

Monitoring Terminal (ODU)


Terminal

RX LEV MON:

Operating

Remarks

Monitoring RX LEV in AGC voltage


using the digital voltmeter or PASOLINK
MONITOR unit * for antenna
orientation.

Use LCT to check the RX LEV in


Maintenance.

Note: *: In order to measure exact performance of AGC V at the RX


LEV MON, it is mandatory required to set Antenna Alignment
Mode to ON as the AGC voltage indication is not guaranteed
outside Antenna Alignment Mode.
It is necessary to set to Antenna Alignment Mode every time
monitor the RX level with the PASOLINK MONITOR unit.

2-78
78 pages

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3. SYSTEM SETUP
This section provides system setup to make up proper system
configuration. The setup is performed accessing to the LCT program using
the PC. For the detail procedure, refer to Section IV Appendix LCT
Operation Manual.

3.1 Equipment Setup


The equipment setup menu decides system fundamental configuration.
The setup of the equipment performs upon PDH (STANDARD) system,
PDH (2-WAY/XC) or SDH system as listed in the following table.
Equipment Setup for PDH (STANDARD)
User Interface

Redundancy Setting

INTFC

Modulation Scheme

Transmission Capacity

TX RF Frequency(No.1) [MHz]
TX RF Frequency(No.2) [MHz]
RX RF Frequency(No.1) [MHz]
RX RF Frequency(No.2) [MHz]
Frame ID(No.1)
Frame ID(No.2)

PDH E1
PDH E1 with LAN
PDH E1 with LAN 156MB (*1)
PDH E3 with LAN
PDH 4PORT LAN with E1
1+0(TERM)
1+1(Hot Standby TERM)
1+1(Twinpath TERM)
16E1 Standard PKG(E/W LAN)
32E1 Standard PKG(E/W LAN)
48E1 PKG
E3 PKG(E/W LAN)
4PORT LAN with E1
4PORT LAN with E1(VLAN)
QPSK
16QAM
32QAM
128QAM (*1)
10MB
20MB
40MB
80MB
100MB
156MB (*1)

(Up to #32)
(Up to #32)

3-1

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Equipment Setup for PDH (STANDARD)


TX Power Control(No.1)
TX Power Control(No.2)
LAN Port Usage

LAN Port Usage (Main)

LAN Capacity(Main/WS) P1-P2

MTPC
ATPC
MTPC
ATPC
Not Used
P1-2 Shared/1Port Only(Main)
P1-2 Separated(Main)
P1=100MB/P2=56MB(*1)
P1-2 Shared/1Port Only(SC)
P1-2 Shared/1Port Only(WS)
P1-4 Shared (Main)
P1-2 Shared/P3-4 Shared (Main)
P1-4 Separated (Main)
P1-4 VLAN
100 (156)(*1) Mbps

LAN Capacity(SC) P1-P2


256 Kbps
LAN Capacity(Main) P1-P2-P3-P4 100 Mbps
---ODU FREQ INFO--TX Start Frequency(No.1) [MHz]
TX Stop Frequency(No.1) [MHz]
Frequency Step(No.1) [MHz]
Shift Frequency(No.1) [MHz]
Upper/Lower(No.1)
Sub Band(No.1)
TX Start Frequency(No.2) [MHz]
TX Stop Frequency(No.2) [MHz]
Frequency Step(No.2) [MHz]
Shift Frequency(No.2) [MHz]
Upper/Lower(No.2)
Sub Band(No.2)

Note:

(only for the E3 INTFC)


(only for the 4P INTFC)

(2 Mbps to 100 (156)(*1) Mbps)


(Main/2 Mbps WS)
(64 Kbps to 256 Kbps) (SC)
(2 Mbps to 100 Mbps)

For the details of setup item of the LAN PORT USAGE,


refer to the LAN INTERFACE (10/100BASE-T(X))
Application and Setting in Section IV.

Note:*1 For High Capacity PDH 32E1(H2990D) interface

3-2

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Equipment Setup for PDH (2-WAY/XC)


User Interface
Redundancy Setting
INTFC
Modulation Scheme (DIR-A)
Modulation Scheme (DIR-B)
Transmission Capacity (DIR-A)

Transmission Capacity (DIR-B)

TX RF Frequency(DIR-A) [MHz]
TX RF Frequency(DIR-B) [MHz]
RX RF Frequency(DIR-A) [MHz]
RX RF Frequency(DIR-B) [MHz]
Frame ID(DIR-A)
Frame ID(DIR-B)
TX Power Control(DIR-A)
TX Power Control(DIR-B)
LAN Port Usage

LAN Capacity (DIR-A) P1-P2


LAN Capacity (DIR-B) P1-P2

PDH E1 with LAN


2-WAY PDH
16E1 2-WAY/XC PKG(E/W LAN)
QPSK
16QAM
QPSK
16QAM
10MB
20MB
40MB
80MB
10MB
20MB
40MB
80MB

(Up to #32)
(Up to #32)
MTPC
ATPC
MTPC
ATPC
Not Used
P1-2 Shared/1Port Only (DIR-A:Main)
P1-2 Shared/1Port Only (DIR-A:SC)
P1-2 Shared/1Port Only (DIR-B:Main)
P1-2 Shared/1Port Only (DIR-B:SC)
P1-2 Star (DIR-A:Main, DIR-B:Main)
P1-2 Star (DIR-A:Main, DIR-B:SC)
P1-2 Star (DIR-A:SC, DIR-B:Main)
P1-2 Star (DIR-A:SC, DIR-B:SC)
P1-2 Mixed (DIR-A:Main, DIR-B:Main)
P1-2 Mixed (DIR-A:Main, DIR-B:SC)
P1-2 Mixed (DIR-A:SC, DIR-B:Main)
P1-2 Mixed (DIR-A:SC, DIR-B:SC)
256 Kbps
80 Mbps
256 Kbps
80 Mbps

(64 Kbps to 256 Kbps)(SC)


(2 Mbps to 80 Mbps) (MAIN)
(64 Kbps to 256 Kbps)(SC)
(2 Mbps to 80 Mbps)

3-3

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Equipment Setup for PDH (2-WAY/XC)


---ODU FREQ INFO--TX Start Frequency(DIR-A) [MHz]
TX Stop Frequency(DIR-A) [MHz]
Frequency Step(DIR-A) [MHz]
Shift Frequency(DIR-A) [MHz]
Upper/Lower(DIR-A)
Sub Band(DIR-A)
TX Start Frequency(DIR-B) [MHz]
TX Stop Frequency(DIR-B) [MHz]
Frequency Step(DIR-B) [MHz]
Shift Frequency(DIR-B) [MHz]
Upper/Lower(DIR-B)
Sub Band(DIR-B)

Note: For the details of setup item of the LAN PORT USAGE,
refer to the LAN INTERFACE (10/100BASE-T(X)) and 2WAY/Cross-connect Application and Setting in Section IV.

3-4

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Equipment Setup for SDH


User Interface

Redundancy Setting

INTFC Main (WORK)

INTFC SUB (PROT)

XPIC Usage

APS Function
Modulation Scheme
Transmission Capacity
TX RF Frequency(No.1) [MHz]
TX RF Frequency(No.2) [MHz]
RX RF Frequency(No.1) [MHz]
RX RF Frequency(No.2) [MHz]
Frame ID(No.1)
Frame ID(No.2)
TX Power Control
LAN Port Usage (Main)
LAN Capacity(Main)
LAN Port Usage (Main)

LAN Capacity(Main)
LAN Port Usage (Main)

LAN Capacity(Main)
LAN Port Usage (SUB)
LAN Capacity(SUB)

SDH STM-1
SDH GbE
2Port LAN
1+0(TERM)
1+1(Hot Standby TERM)
1+1(Twinpath TERM)
STM-1(Optical)
STM-1(Electrical)
SDH GbE
2Port LAN
SDH GbE (VLAN)
Not Used
STM-1 (Optical)
WS
WS/LAN
Not Used
Used (Main Master)
Used (SUB Master)
Unavailable
Available
128QAM
156MB

(Up to #32)
(Up to #32)
MTPC
ATPC
USED
150Mbps
P1=75MB/P2=75MB
P1=100MB/P2=50MB
Best Effort
P1=100MB/P2=Not Used
150Mbps
Port Shared
Stack Master(Port Shared)
Stack Slave
150Mbps

(fixed)
(fixed)

(fixed when SDH GbE INTFC is applied.)


(fixed when SDH GbE INTFC is applied.)
(selectable when SDH LAN/WS INTFC is
applied.)

(fixed when SDH LAN/WS INTFC is applied.)


(selectable when GbE INTFC-E is applied.)

(selectable when GbE INTFC-E is applied.)

P1-2 Shared/1Port Only(WS)


P1-2 Shared/1Port Only(SC)
64kbps
128kbps
192kbps
256kbps
2Mbps

3-5

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Equipment Setup for SDH


---ODU FREQ INF--TX Start Frequency(No.1) [MHz]
TX Stop Frequency(No.1) [MHz]
Frequency Step(No.1) [MHz]
Shift Frequency(No.1) [MHz]
Upper/Lower(No.1)
Sub Band(No.1)
TX Start Frequency(No.2) [MHz]
TX Stop Frequency(No.2) [MHz]
Frequency Step(No.2) [MHz]
Shift Frequency(No.2) [MHz]
Upper/Lower(No.2)
Sub Band(No.2)

3-6

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.2 Provisioning Setup


The provisioning setup menu decides system fundamental functions.
The setup of the provisioning performs upon PDH system or SDH system
as items listed in the following table.

Provisioning Setup PDH


Provisioning
LAN Port Setting

Port 1

Port 2

Port 3
Port 4
LAN port control

Switching Function
2M Framing

Disabled
Enabled
Unframed
PCM31 (FAS+CRC)
PCM31(FAS)
PCM30C(MFAS+CRC)
PCM30(MFAS)
Port Usage
Not Used
Used
Speed & Duplex
AUTONEG (Auto-MDI/MDI-X)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Flow Control
Off
On
Collision Report
Not Report
Report
Link Loss Forwarding
Disabled
Enabled
Port Usage
Not Used
Used
Speed & Duplex
AUTONEG (Auto-MDI/MDI-X)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Flow Control
Off
On
Collision Report
Not Report
Report
Link Loss Forwarding
Disabled
Enabled
For 4P LAN INTFC (same as above Port 1/Port2)
For 4P LAN INTFC (same as above Port 1/Port2)
Main Link Down Control
Disabled
Enabled
MAC Address Learning
Off
On

3-7

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Provisioning Setup PDH


CH Setting (CH Setting 1)
E3 Setting (CH Setting 1)
CH Setting (CH Setting 2)

XC Setting *1

BER Threshold Setting


SC Assignment *4

TX Power Control

Condition for TX/RX SW

Relay Setting

3-8

E1 Channel Setting
E3 Channel Setting
Wayside Channel Setting
CH Usage Error Report
AIS Activation Condition
AIS Generated Report
AIS Received Report
E1 Port Impedance (CH1)
E1 Port Impedance (CH2)
E1 Port Impedance (CH3)
E1 Port Impedance (CH4)
E1 Port Impedance (CH5-8)
E1 Port Impedance (CH9-16)
E1 Port Impedance (CH17-24)
E1 Port Impedance (CH25-32)
E1 Port Impedance (CH33-40)
E1 Port Impedance (CH41-48)
Cross Connect Function (XC) *2
DIR-A to DIR-B Connect Setting
DIR-A to Tributary Connect Setting
DIR-B to DIR-A Connect Setting
DIR-B to Tributary Connect Setting
Tributary to DIR-A Connect Setting
Tributary to DIR-B Connect Setting
Tributary to Tributary Connect Setting
DIR-A to DIR-B ALL Connect Setting
DIR-A to Tributary ALL Connect Setting
High BER Threshold
Low BER Threshold
RS-232C-1/2
V11-1/2
V-11-1/2 Direction Setting
ATPC Threshold Level(No.1/2) [dBm]
Additional ATT(No.1/2) [dB]
ATPC Range(MAX)(No.1/2) [dB]
ATPC Range(MIN)(No.1/2) [dB]
ATPC Power Mode
COMM ALM Mode
MTPC TX Power (No.1/2) [dBm]
ATPC Threshold Level(No.1/2) [dBm]
Additional ATT (No.1/2) [dBm]
COMM ALM Mode
TX SW Priority *6
TX SW Lock in Usage*6
TX SW Reverse Function Usage*6
TX SW Sensitivity*6
RX SW Priority *6
RX SW Maintenance Mode
RX SW Condition-Early Warning
ALM output for RL1 to RL6
HK output for RL3 to RL6
Cluster1 to Cluster4 input
Cluster1 to Cluster4 output

Not Used
Used
Not Used
Used
Not Used
Used
Not Report Report
LOF+ High BER LOF
Not Report Report
Not Report Report
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
120 [ohm] 75 [ohm]
Enabled
Disabled
*3
*2, *3
*3
*3
*2, *3
*3
*2, *3
*3
*2, *3
1E-3 1E-4 1E-5
1E-6 1E-7 1E-8 1E-9
Not Used SC1 SC2 SC3 SC4
Not Used SC1 SC2 SC3 SC4
Co-directional
Contra-directional

Hold
Mute

Max
Hold

Min
*5

Mute

Hold

*5

Non-Priority Priority No.1


Not Used Used
Not Used Used
Normal
High
Non-Priority Priority No.1
Manual Forced
Included EW Excluded EW
Out
HK
Disabled
Enabled
Out

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Provisioning Setup PDH


TCN Threshold(15min)

TCN Threshold(1day)

PMON Select

Others

VLAN/QoS
(for 4P LAN INTFC-E)

OFS
UAS
ES
SES
BBE
SEP
OFS
UAS
ES
SES
BBE
SEP
RX Level TCN Threshold (dBm)
RX Level TCN Threshold(No.2) (dBm)
SES Activation Condition
EOW2 External Setting
Alarm Correlation Capacity
VLAN Mode

QoS Mode

30 (%)
15 (%)
Normal
Invert
Off
On
Port VLAN
Tag VLAN
Port VLAN + Tag VLAN
Double Tag VLAN
Disable
802.1Q User Priority
ToS User Priority
DSCP User Priority
Disable

Notes: *1:When the 16E1 2-WAY/XC PKG (E/W LAN) is provided.


*2:.It is available when following configuration:
Redundancy Setting;
1+0 (TERM),
1+1 (Hot Standby TERM) or
1+1 (Twinpath TERM)
with
INTFC 16E1 2-WAY/XC PKG (E/W LAN)
*3:When the 2-WAY PDH is selected in Redundancy
Setting
*4:When 2-WAY PDH is setup, the setting of SC
Assignment for DIR-A and DIR-B is necessary.
*5:Select ODU output powermode when the
communication failes between IDU and ODU due to
some ploblemes.
When Mute is set, the ODU output power will be
muted.(Default)
When Hold is set,the ODU output power will be hold
(Should consider neighboring system.)
*6: Only for Hot Standby.

3-9

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Provisioning Setup SDH


Provisioning
BER Threshold Setting

SUB INTFC

SC Assignment

LAN Port Setting


(For GbE INTFC)

3-10

High BER Threshold


Low BER Threshold
E-BER (DMR)
SD (DMR)
E-BER (MUX)
SD (MUX)
SUB INTFC
WS Impedance
WS AIS Generation Report
WS AIS Regeneration Report
RS-232C-1/2

1E-3 1E-4 1E-5


1E-6 1E-7 1E-8 1E-9
1E-3 1E-4 1E-5
1E-6 1E-7 1E-8 1E-9
1E-3 1E-4 1E-5
1E-6 1E-7 1E-8 1E-9
E1 Wayside
120 [ohm]
75 [ohm]
Not Report
Report
Not Report
Report
Not Used SC1 SC2 SC3 SC4
E1 (MUX)F1(MUX)E1(DMR)F1(DMR)

V11-1/2

Not Used SC1 SC2 SC3 SC4


E1 (MUX) F1(MUX) DCCr(MUX) E1
(DMR) F1(DMR) DCCr(DMR) F1(DMR)

V-11-1/2 Direction Setting


LAN Port Setting
Switching Function
Port
Media Type
Speed & Duplex
Flow Control
Link Loss Forwarding

Co-directional
Disable

Contra-directional
Enable

SFP
RJ-45
AUTONEG (1000MB Full Duplex)
Off
On
Disabled
Enabled

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Provisioning Setup SDH


LAN Port Setting
(For LAN/WS INTFC)

INTFC (Main) Setting


Switching Function
Clock Souce Setting
Port1
Port Usage
Speed & Duplex

Flow Control
Collision Report
Port2
Port Usage
Speed & Duplex

LAN Port Setting


(For GbE INTFC-E)

Flow Control
Collision Report
Link Loss Forwarding
INTFC (Main) Setting
Switching Function
Port1
Port Usage
Speed & Duplex

Flow Control
Collision Report
Link Loss Forwarding

Internal Clock DMR Internal -> Clock

Not Used
Used
AUTONEG (Auto-MDI/MDX)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report Report
Not Used
Used
AUTONEG (Auto-MDI/MDX)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report Report
Disabled
Enabled
Disabled

Enabled

Not Used
Used
AUTONEG (1000M-Full)
AUTONEG (Auto-MDI/MDX)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report Report
Disabled
Enabled

3-11

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Provisioning Setup SDH


Port 2
Port Usage
Speed & Duplex

Flow Control
Collision Report
Link Loss Forwarding
Port 3
same as above Port2
Port 4
same as above Port2
LAN port control
Main Link Down Control

STM-1 Setting
ALS
TX Power Control

Condition for TX/RX SW

Condition for APS

3-12

MAC Address Learning


MS-AIS Generation
ALS Function
ALS Interval
ATPC Threshold Level(No.1/2) [dBm]
Additional ATT(No.1/2 [dB]
ATPC Range(MAX)(No.1/2) [dB]
ATPC Range(MIN)(No.1/2) [dB]
ATPC Power Mode(No.1/2)
COMM ALM Mode
MTPC TX Power (No.1/2) [dBm]
ATPC Threshold Level(No.1/2) [dBm]
Additional ATT(No.1/2) [dB]
COMM ALM Mode
TX SW Priority*6
TX SW Lock in Usage*6
TX SW Reverse Function Usage*6
TX SW Sensitivity*6
RX SW Priority*6
RX SW Maintenance Mode
RX SW Condition-Early Warning
APS Maintenance Mode
APS Condition-SF(PROT)
APS Condition-Signal Degrade-SD(B1)
Lock in Usage
Lock in Count [times]
Lock in Detect Time [min]
Lock in Hold Time [hours]

Not Used
Used
AUTONEG (Auto-MDI/MDI-X)
10M-Half (MDI)
10M-Full (MDI)
100M-Half (MDI)
100M-Full (MDI)
10M-Half (MDIX)
10M-Full (MDIX)
100M-Half (MDIX)
100M-Full (MDIX)
Off
On
Not Report
Report
Disabled
Enabled

Disabled,
Radio Only
Radio + LLF(Any Port)
Radio + LLF(ALL Port)
Off
On
Disabled
Enabled
Disabled
Enabled
60sec 180sec 300sec

HOLD
Mute

Max MIN
Hold *5

Mute
Hold *5
Non-Priority Priority No.1
Not Used Used
Not Used Used
Normal
High
Non-Priority Priority No.1
Manual Forced
Included EW Excluded EW
Manual
Forced
Priority High Priority Low
Included SD Excluded SD
Not Used
Used

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Provisioning Setup SDH


Relay Setting

TCN Threshold(15min)

ALM output for RL1 to RL6


HK output for RL3 to RL6
Cluster1 to Cluster4 input
Cluster1 to Cluster4 output
DMR/OCR/RCVR
MUX OCR/RCVR

TCN Threshold(1day)

DMR/OCR/RCVR
MUX OCR/RCVR

PMON Select

RX Level TCN Threshold [dBm]


SES Activation Condition
EOW2 External Setting
Alarm Correlation Capacity
VLAN Mode

Others

VLAN/QoS
(for GbE INTFC-E)

QoS Mode

Out
HK
Disabled
Out
OFS
UAS
ES
SES
BBE
SEP
OFS
UAS
ES
SES
BBE
SEP

Enabled

30[%]
15[%]
Normal
Invert
Off
On
Port VLAN
Tag VLAN
Port VLAN + Tag VLAN
Double Tag VLAN
Disable
802.1Q User Priority
ToS User Priority
DSCP User Priority
Disable

3-13

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.3 Events and Performance


The alarm and status condition are based upon equipment setup and
provisioning setup, therefore indication items vary depending on the those
setup.
The summarized event and performance monitoring that are displayed on
the LCT PC are listed in the following table. For the detailed items, refer
to Section IV Appendix LCT OPERATION MANUAL.

Event List PDH


Alarm Status
ODU
Type Mismatch
TX Power
TX Input
Linearizer
RX Level
APC
ODU CPU/Cable Open
Mute Status
TX SW Lock in Status
TX SW Reverse REQ
TX SW Status
RX SW Status
MODEM
Unequipped
Type Mismatch
Module
LOF
Frame ID
High BER
Low BER
Early Warning
MOD
DEM
Input Voltage
Power Supply
IF Cable Short
Linearizer Status
Linearizer
Cable EQL
ATPC Power Mode
CTRL
CTRL Module
MMC

3-14

: only Hot standby


configuration
: only Hot standby
configuration
: only 1+1 configuration
: only 1+1 configuration

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Event List PDH


INTFC
Unequipped
Type Mismatch
Module
Input LOS E3 CH
Input LOS WS CH
Input LOS CH
Usage Error CH
AIS Generated CH
AIS Received CH
LAN Link
LAN Collision
Link Loss Forwarding (LLF)
Speed & Duplex
Inphase

: only E3 interface
*1
*1 : in respective E1 CH
*1
*1
*2
*2 : for LAN transmission
*2
*2
: only 1+1 configuration

UAE
UAE
TCN 15min 1day
Total-15min
Total -1day
TCN-RX LEV
TCN-RX LEV-15min
TCN-RX LEV-1day
PMON(History)
RX Level
RX Level(15min)
RX Level(1day)
Total
Status
OFS
SEP
BBE
ES
SES
UAS
RMON(Line)(15min)

only for LAN


Status
RX UNICAST
RX BROADCAST
RX MULTICAST
RX PAUSE
RX CRC ERR
RX ALIGNMENT ERR
RX SYMBOL ERR
RX UNDERSIZE
RX FRAGMENTS
RX Pkts 64
RX Pkts 65 to 127
RX Pkts 128 to 255
RX Pkts 256 to 511

3-15

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Event List PDH


RX Pkts 512 to 1023
RX Pkts 1024 to 1536
TX JABBERS
TX UNICAST
TX BROADCAST
TX MULTICAST
TX PAUSE
TX COLLISION

Notes: *1,*2 Refer to the following tables.


Status of E1 Channel
Input LOS
CH1
CH2
CH3
CH4

Normal
Normal
Normal
Normal

AIS Received
Normal
Normal
Normal
Normal

AIS Generated
Normal
Normal
Normal
Normal

Usage Error
Normal
Normal
Normal
Normal

Status of LAN PORT


Link
PORT1
PORT2
PORT3
PORT4

3-16

Link
Link
Link
Link

Collision
Normal
Normal
Normal
Normal

LLF
Under Execution
Normal
Normal
Normal

Speed & Duplex


100M-Full (MDIX)
10M-Half (MDI)
10M-Half (MDI)
10M-Half (MDI)

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Event List SDH


Alarm Status
ODU
Type Mismatch
ODU
TX Power
TX Input
Linearizer
RX Level
APC
ODU CPU
Mute Status
LO REF
TX SW Lock in Status
TX SW Reverse REQ
TX SW Status
RX SW Status

: only XPIC configuration


: only Hot standby
configuration
: only Hot standby
configuration
: only 1+1 configuration
: only 1+1 configuration

MODEM
Unequipped
Type Mismatch
Module
LOF
Route ID
High BER
Low BER
Early Warning
MOD
DEM
Input Voltage
Power Supply
IF Cable Short
Linearizer Status
Linearizer
Cable EQL
XIF
XPIC Status
XREF
ATPC Power Mode

Only XPIC applies

CTRL
CTRL Module
MMC Mount
APS SW Fail
APS Online Status
APS Lock in Status
XCTRL
XCTRL Mode Mismatch

: only APS configuration


: only APS configuration
: only APS configuration
: only XPIC configuration
: only XPIC configuration

3-17

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Event List SDH


UAE
STM-1(1)/UAE(MUX)
STM-1(1)/UAE(DMR)
INTFC (Main)
Unequipped
Type Mismatch
LOS (MUX)
LOS (DMR)
LOF (MUX)
LOF (DMR)
Output Control
E-BER (MUX)
E-BER (DMR)
SD (MUX)
SD (DMR)
In-Phase
TF
INTFC (Main)
Unequipped
Type Mismatch
Module
LAN Link
Link Loss Forwarding
Speed & Duplex
LOS (DMR)
LOF (DMR)
E-BER (DMR)
SD (DMR)
In-Phase
TF

For LAN Interface

INTFC (Sub)
Unequipped
Type Mismatch
LOS (MUX)
E-BER (MUX)
E-BER (DMR)
SD (MUX)
SD (DMR)
Output Control
In-Phase
LOS (DMR)
LOF (MUX)
LOF (DMR)
TF
Unequipped

3-18

OPT INTFC applies APS

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Event List SDH


Type Mismatch
Module
LAN Link
LAN Collision
Link Loss Forwarding
Speed & Duplex
WS Input LOS
WS AIS Generated
WS AIS Received

*1
*1 When LAN Port
*1
*1
Only WS applies

TCN-RX LEV
TCN-RX LEV-15min
TCN-RX LEV-1day
TCN 15min 1 day
MUX-15min
MUX-1day
DMR-15min
DMR-1day
MUX-15min (P)
MUX-1day(P)
DMR-15min(P)
DMR-1day(P)

only APS configuration

3-19

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Event List SDH


PMON(History)
RX Level

DMR (W)

DMR (W)

MUX (W)

MUX (W)

RX Level(15min)
RX Level(1day)
(1day)
Status
OFS
SEP
BBE
ES
SES
UAS
(15min)
Status
OFS
SEP
BBE
ES
SES
UAS
(day)
Status
OFS
SEP
BBE
ES
SES
UAS
(15min)
Status
OFS
SEP
BBE
ES
SES

RMON(Line)(15min)

only for LAN


Status
RX UNICAST
RX BROADCAST
RX MULTICAST
RX PAUSE
RX CRC ERR
RX ALIGNMENT ERR
RX SYMBOL ERR
RX UNDERSIZE
RX FRAGMENTS
RX Pkts 64
RX Pkts 65 to 127
RX Pkts 128 to 255
RX Pkts 256 to 511

3-20

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Event List SDH


RX Pkts 512 to 1023
RX Pkts 1024 to 1536
TX JABBERS
TX UNICAST
TX BROADCAST
TX MULTICAST
TX PAUSE
TX COLLISION

Notes: *1 When the LAN/WS INTFC is provided, status of each LAN


PORT is displayed as follows.
Status of LAN PORT
Link
Sub PORT1
Sub PORT2

Link
Link

Collision
Normal
Normal

LLF
Normal
Normal

Speed & Duplex


100M-Full (MDIX)
100M-Full (MDIX)

Notes:For the GbE INTFC, there are distinctions for the


following functions from the 10BASE-T/100BASE-Tx
1. RX Undersize: Unavailable.
2. RX Fragments: Unavailable.
3. RX Symbol Errors:
For SFP: Available
For RJ-45: Unavailable (un-counting, only 0 is
indicated.)
4. TX Multicast PKts (Including number of the TX pause
packets.)
5. RX Multicast PKts (Including number of the RX pause
packets.)
6. Countable packet size for the following items shown in
right side of the table and reading must be taken place
as follows. (The indication will not be taken placed.)
Indication
15 RX Pkts 1024-1536
16 RX Pkts 1537-MAX

Reading
RX Pkts 1024-1518
RX Pkts 1519-MAX

7. The RX Alignments Error is counted as an RX CRC


ERR.

3-21

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.4 Control
The control condition is based upon equipment setup and provisioning
setup, therefore control items vary depending on the those setup.
The control items that are displayed on the LCT PC are listed in the
following table. the control operation can be performed in Maintenance
ON.

Control List (PDH)


Control
Maintenance
TX SW Manual Control
RX SW Manual Control
ATPC Manual Control(No.1)
ATPC Manual Control(No.2)
TX Mute Control(No.1)
TX Mute Control(No.2)
CW Control(No.1)
CW Control(No.2)
IF Loopback(No.1)
IF Loopback(No.2)
Main CH Loopback (Near End)
Main CH Loopback (Far End)
Main CH1 Loopback (Near End)
Main CH2 Loopback (Near End)
Main CH1 Loopback (Far End)
Main CH2 Loopback (Far End)
LAN Device Reset
Offline Maintenance
DADE Adjust
RF Shift Frequency Setting(No.1)
RF Shift Frequency Setting(No.2)
Antenna Alignment Mode(No.1)
Antenna Alignment Mode(No.2)

*1
*1
*1
*1
*1
*1
*2
only for E3 Interface

*1

*1

Notes *1:only for 1+1 Configuration.


*2:XC in terminal also enables. In 2-WAY PDH, not appears.

3-22

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Control List (SDH)


Control
Maintenance
TX SW Manual Control
RX SW Manual Control
RX SW Maintenance Mode
ATPC Manual Control(No.1)
ATPC Manual Control(No.2)
TX Mute Control(No.1)
TX Mute Control(No.2)
CW Control(No.1)
CW Control(No.2)
APS Manual Control (Auto/Working/Protection)
APS Maintenance Mode
IF Loopback(No.1)
IF Loopback(No.2)
Main Loopback (Near End)
Main Loopback (Near End) INTFC (1)
Main Loopback (Near End) INTFC (2)
Main Loopback (Far End)
ALS Restart
XPIC Control Local(No.1)
XPIC Control Local(No.2)
XPIC Control Remote(No.1)
XPIC Control Remote(No.2)
LAN Device Reset
Offline Maintenance
DADE Adjust
RF Shift Frequency Setting(No.1)
RF Shift Frequency Setting(No.2)
Antenna Alignment Mode(No.1)
Antenna Alignment Mode(No.2)

*1
*1

*1
*1
*1
: Only APS configuration
: Only APS configuration

*1
: Only APS configuration
: Only APS configuration
: Only Optical INTFC
: Only XPIC configuration
: Only XPIC configuration
: Only XPIC configuration
: Only XPIC configuration

*1

*1

Note:*1:only for 1+1 Configuration.

3-23

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5 Setup Description


The following describes to select suitable functions for the system
operation by the provisioning setup.

3.5.1 Automatic Laser Shutdown Control (OPT INTFC) (SDH)


The STM-1 INTFC (only for OPT) is provided with the Automatic Laser
Shutdown (ALS) function that can be enabled or disabled. If the ALS
function is enabled, the laser output is periodically turned ON and OFF
when the optical cable carrying the STM-1 signal is disconnected
inadvertently, or intentionally during maintenance. When the ALS
function is disabled, the laser output is always ON even if the optical cable
is disconnected. Fig. 3-1 shows a block diagram of the ALS function.
If a fault occurs at point A and the absence of the optical input signal in the
RX 2 lasts for 550 50 msec (STM-1 LOS alarm condition), the optical
signal bound for the RX 1 (MUX equipment) from the TX 2 (OPT INTFC
module) is interrupted by a control signal generated inside the OPT INTFC
module. The MUX equipment detects the loss of signal at RX1 and the
ALS function in the MUX will, subsequently, turn off the laser output of
TX1. When the fault at point A is cleared the system can be restored by
controlling the laser output of TX2 through one of the following modes:
Automatic control
Manual restart (2 sec.) control
Manual restart (90 sec.) control
(a) Automatic Control
When 60, 180 or 300 sec.(selectable) have elapsed after the optical
signal entering RX 2 is cut off, the IDU emits laser signal from TX
2 to RX 1 for 2 sec. This would then cause the laser output of TX1
to turn on. If, at this time, the fault at point A has been cleared, the
ALS function will be released and the operation will return to
normal.
(b) Manual Restart (2 sec.) Control
Upon receiving a command signal for manual restart from the LCT
or the PASOLINK network management terminal (PNMT) while
the optical input signal to the RX 2 is off, the IDU emits the laser
signal from the TX 2 to the RX 1 for 2 0.25 sec. This would then
cause the laser output of TX1 to turn on. If, at this time, the fault at
point A has been cleared, the ALS function will be released and
the operation will return to normal (if not it returns to automatic
condition).

3-24

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

(c) Manual Restart (90 sec.) Control


Upon receiving a command signal for manual restart for test from
the LCT or the PNMT while the optical input signal to the RX 2 is
off, the IDU emits the laser signal from the TX 2 to the RX 1 for 90
10 sec. This would then cause the laser output of TX1 to turn on.
If, at this time, the fault at point A has been recovered, the ALS
function will be released and the operation will return to normal (if
not it returns to automatic condition).
MUX
EQUIPMENT

TX1

CTRL

OPT INTFC
RX2
O/E
RLOS

TX2

550 50 ms
TIMER

CLEAR

9010S
TX ON
TIMER

20.25S
TX ON
TIMER

ALS CONT
ENABLE/DISABLE
60/180/
300 sec.
DELAY

CONT
RX1

2S
TX ON
TIMER

O/E
SB/DATA
BUS

DATA BUS

LCT or PNMT

Fig. 3-1 ALS System Functional Block Diagram

3-25

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5.2 Automatic Protection Switching (APS) (OPT INTFC Optional


APS Configuration) (SDH)
(a) Line Protection
The Automatic Protection Switching (APS) provides for unidirectional line protection against optical cable interface failures. It is
performed by detected alarm condition or remote control signal.
Module Failure

SW CTRL

LOS/LOF/BER
DET
OPT IN
Working

STM-1 (OPT)
INTFC

only 1+1
SW

MODEM

OPT OUT

Remote

CTRL

SW CTRL
SW

Protection

OPT IN
OPT OUT

STM-1 (OPT)
INTFC

MODEM

LOS/LOF/BER
DET

Module Failure

Fig. 3-2 OPT APS System

The STM-1 (OPT) INTFC monitors the OPT line input signal
interface condition and when an alarm condition occurs in the optical
cable or optical interface module, APS is activated. Also the APS is
activated when remote control signal is received.
Uni-directional APS is performed only in the receiving section of the
local side when a failure or signal degradation of the received signal
is detected in one direction. Fig. 3-3 shows APS switching mode.

3-26

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

SW CTRL
PASOLINK NEO

ASSOCIATED EQUIPMENT
Received OPT failure

(Work)

WORKING
WORKING

(Prot)

PROTECTION
PROTECTION

STM-1 (OPT) INTFC


(No.1)

(1)

STM-1 (OPT) INTFC


(No.2)

WORKING
WORKING

(Work)

STM-1 (OPT) INTFC


(No.1)

(2)
PROTECTION
PROTECTION

(Prot)

STM-1 (OPT) INTFC


(No.2)

SW CTRL
ASSOCIATED EQUIPMENT

(Work)
(1)

Received OPT failure

WORKING
WORKING

PASOLINK NEO

STM-1 (OPT) INTFC


(No.1)

(Prot)

PROTECTION
PROTECTION

STM-1 (OPT) INTFC


(No.2)

(Work)

WORKING
WORKING

STM-1 (OPT) INTFC


(No.1)

(Prot)

PROTECTION
PROTECTION

STM-1 (OPT) INTFC


(No.2)

(2)

Uni-directional Mode Line Protection


Note:

ON LINE
OFF LINE

Fig. 3-3 Line Protection

3-27

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

(b) APS Function Setup


The APS switchover is performed with the following order of priority
of two (2) modes.
(1) When APS Condition-SF is lower priority (default).
UNEQUIP > LKI*1 > FSW > SF > SD*2 > MSW
(2) When APS Condition-SF is higher priority.
UNEQUIP > LKI*1 > SF(P) > FSW > SF(W) > SD*2 > MSW
Notes: *1 Excluding when the Lock in Usage is set Not Used.
*2:Excluding when the APS Condition-SD(B1) is set to
Excluded SD.
UNEQUIP:Unequipped redundant STM-1 INTFC (OPT).
LKI:Lock in (see following descriptions Lock in for detail)
FSW:Forced Control (see following descriptions when APS
Maintenance Mode is set to Forced)
SF:Signal Fail (see following descriptions of APS
Condition-SF(PROT)
SF(P); Signal Fail of Protection side
SF(W); Signal Fail of Working side
SD;Signal Degrade (see following descriptions APS
Condition-SD(B1) for detail)
MSW;Manual control (see following descriptions when APS
Maintenance Mode is set to Manual)

3-28

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

LCT MENU
Alarm/Status
Equipment Setup
Inventory
AUX I/O
Maintenance
Provisioning
BER Threshold Setting
SC Assignment
STM-1 Setting
TX Power Control
Condition for TX/RX SW
Condition for APS
Relay Setting
TCN Threshold (15min)
TCN Threshold (1day)
PMON Select
Others
Metering
PMON(Current)
PMON(History)

---Condition for APS--APS Maintenance Mode

Manual

APS Condition-SF(PROT)

Priority High

APS Condition-SD(B1)

Included SD

Lock in Usage

Not Used

Lock in Detect Count [times]


Lock in Detect Time [min]
Lock in Hold Time [hours])

Range

4
10
24

Forced
Priority Low
Excluded SD
Used
1 to 255
1 to 60
1 to 48

APS Maintenance Mode


This is a setup to give priority to manual control operation in
maintenance.
Manual:
Give priority to alarm events in maintenance
operation. In this mode, manual control disables the
operation under alarm condition.
Forced:
Give priority to forced control in maintenance
operation. In this mode, manual control enables the
operation under alarm condition and the alarmed side
can be selected.
Caution: When the APS Maintenance Mode is set to
Forced in provisioning, APS manual control can
select either Working or Protection line though one
is alarmed. Then, take care switching to avoid traffic
interruption.
APS Condition-SF(PROT):
This is a setup to give higher priority to switchover by SF in
Protection side.
Priority High:This setup gives highly priority to SF of Protection
side (installed in INTFC Slot2) for switchover
control condition. Since the setup gives priority
higher than the Forced Control, the ONLINE is
maintained in Main side (installed in INTFC Slot1)
under occurrence of SF condition of Protection side.

3-29

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

APS Condition-SD(B1)
This is a setup that it includes the SD or excludes SD for the
switchover control condition. When including it, the switchover is
performed when SD reaches the threshold value which is set in BER
Threshold/SD (MUX) in provisioning.
Include SD: Including SD for switchover condition
Exclude SD:Excluding SD for switchover condition
Lock in
The function is used to pause the switchover activation for a period of
time when in the switchover of frequent occurrence.
The following setting is needed to be used for it.
Lock in Count:
Setup for the Lock in threshold value of the
switchover number of times.
(setting range: 1 to 255 times)
Lock in Detect time: Setup for the watching interval of counting
number of times for Lock in.
(setting range: 1 to 60 minutes)
Lock in Hold time: Setup for the duration of pause of switchover
in the Lock in condition.
(setting range: 1 to 48 hours)
The Lock in status can be observed on the Alarm/Status of LCT
display.
The Lock in condition may be released after passing the Lock in Hold
time or the change of setting.
The following is an example in default value.
Lock in Count: 4
Lock in Detect time: 10
Lock in Hold time: 24
This sets into the Lock in condition when the switchover is activated
more than 4 times within 10 minutes interval of watching number of
times. The switchover activation pauses during 24 hours after set in
the Lock in condition. The Lock in condition will be released after
passing of 48 hours and it sets into normal mode.
When it will be manually released that under the Lock in condition,
perform resetting by changing parameter value or changing the
setting condition to Lock in Usage Not Used.

3-30

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5.3 Automatic Transmitter Power Control


The automatic transmit power control (ATPC) function automatically
varies the TX output power according to path conditions. In the SHF and
EHF band, fading exerts heavy influences on propagation, causing the
receive signal level at the opposite station to vary. The ATPC function
operates by controlling the transmit output power of the opposite station
according to the variation of the received signal level at the local station.
ATPC provides the following advantages:
Improvement in up fading characteristics
Improvement in residual BER characteristics
Reduction of interference to intra system
Reduction of interference to inter system
Note: In the XPIC configuration, ATMC/MTPC setup and action
control in the Sub Master station are applied from the Main
Master station.
A functional block diagram of the ATPC operation is shown in Fig.
3-4.
ATPC improves the BER characteristics under adverse changes in
climatic conditions and reduces the possibility of interference. To
implement ATPC, the received level (RX LEV) is detected by the
Receiver (RX) in the ODU and passed to the CPU in the CTRL
module. The CPU then determines whether the transmit output
power needs to be controlled. This is based on the transmit output
power and the minimum and maximum values of the output control
range (ATPC range). ATPC is relevant for the receiving threshold
level that were previously specified using the LCT or PNMT (as
ATPC Threshold Level).
A control signal (POWER CTRL), whose function is to maintain the
received RX signal level (RSL) by decreasing or increasing the TX
output power of the opposite station, is generated by the CTRL
module through the MD Unit. This control signal is based on the
result of comparison between the current receiver input level and
the preset receiving threshold level. This control signal is sent to the
opposite station to control its transmit output power.
At the opposite station, this control signal is detected by the CTRL
module. The TR Unit, in accordance with this control signal,
produces a control that will either raise, lower or maintain the
current TX output power.

3-31

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

TRANSMITTING STATION

MODEM

RECEIVING STATION

TX

RX IN LEV

POWER CONT

REMOTE

MODEM

RX

CTRL

CTRL

REMOTE
ATPC CTRL

ATPC CTRL

MODEM

RX

TX

MODEM

Fig. 3-4 ATPC, Functional BLock Diagram

Example of ATPC setting.


Where ATPC MAXIMUM PWR of ATPC Range is set to 0 dB, ATPC
MINIMUM PWR is set to -10 dB and RX Threshold to -55 dBm. In this
case, if RX level is lower than -55 dBm, monitor/control is performed with
the interval of 8 msec. RX level is monitored in 1 dB step, and TX output
is controlled in 1 dB step.
However, a fixed hysteresis of 5 dB referred to the RX Threshold is
implemented for ATPC operation.
Example: If RX Threshold is set to -55 dBm, no output control is made
unless the RX level goes below -55 dBm or goes above -50 dBm, so that
the receive level is maintained within -55 to -50 dBm by ATPC.
In this midway condition of hysteresis range, it looks the intermission of
ATPC operation. But when RX level slips out once from hysteresis range,
ATPC operation recovers to normal. Please pay attention to avoid that the
nominal RX level fall into this hysteresis range, because it doesnt get
significant ATPC operation.
ATPC feedback signal shutdown or maximum power condition continues
over 90 seconds, ATPC controller decide to stop ATPC operation in order
to avoid failures that be generated by unstable condition. After recovery of
unstable condition (feed back signal recovery or deep fading eliminated,
etc.), ATPC starts to control. As mentioned above please be careful about
5dB hysteresis range, and get out of the way with enough margin in
normal operation.

3-32

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

-50 dBm
5 dB
(ATPC
HYSTERESIS)

RX LEVEL

-55 dBm
(RX THRESHOLD
LEVEL)

3-33

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

Using MTPC-ATPC
The ATPC Control System of the PASOLINK transmits the information on
the receiving level to the opposite station and controls the transmission
level of its local station in accordance with the receiving level of the
opposite station. Transmission level control can be used not only for
setting the same operation (ATPC-ATPC) between local station and
opposite station but also for operation in combination of stations with
different operations (MTPC-ATPC, ATPC-MTPC). The station set in
MTPC mode is not controlled by the information from opposite station but
is fixed in its transmitting output level.
Even if the station is set in the MTPC mode, the opposite station is likely
to be set in the ATPC mode. Therefore, setting the RX Threshold (ATPC
Threshold level) is required for controlling the transmission level of the
opposite station. Between the stations that are respectively set in the
MTPC mode, however, the setting is disabled.
The following is an example of operation between stations set in MTPCATPC mode.
STATION A

PASOLINK
ODU
MTPC
(RX Threshold: 50 dBm)

STATION B

PASOLINK
ODU
ATPC

The transmitting level of station B is controlled so that the receiving level


of station A in the above figure reaches the RX Threshold set level (50
dBm) set in station A. This method is used in station A for reducing the
level of interference to other route. As station A is set in the MTPC mode,
the transmitting level is kept unchanged.
An example of using MTPC-ATPC is shown below. As shown in the
figure, in the master station communicating with many substations, waves
gather from substations possibly causing interferences. Therefore,
substations must be set in the ATPC mode to minimize the diffraction
(interference) to other routes while reducing the receiving levels from
individual substations to the minimum. In substations, there is little
possibility of occurring interferences; therefore, the master station is set in
the MTPC mode to permit transmission at a constant level.

3-34

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

(MTPC)
MASTER
STATION

(ATPC)
SUBSTATION 1

(ATPC)
SUBSTATION 2

(B)

(A)
(C)
(ATPC)
SUBSTATION 5
(ATPC)
SUBSTATION 3
(ATPC)
SUBSTATION 4
: Diffraction to other route.
(A),(B)
(C) : RX received level down.

A constant transmit output power in both MTPC and ATPC is maintained


using the ALC function which is provided in the RF CKT module. The
ALC circuit detect the transmit output power using a diode to obtain a DC
voltage proportional to the transmit power. The gain of the RF amplifier is
controlled inversely with this detected DC voltage to maintain the transmit
output power within the specified limits.

When the ATPC malfunction occurs, transmitter output power is


maintained at the following level according to the ATPC mode. The ATPC
mode is set in provisioning using LCT.
Hold:Maintain the TX output level at the current level, when the
ATPC malfunction occurs.
MAX:Maintain the TX output level at ATPC maximum level, when
the ATPC malfunction occurs.
Note: Recommended to set to MAX mode when the norminal
receive signal level is out of ATPC range
MIN:Maintain the TX output level at ATPC minimum level, when
the ATPC malfunction occurs.
Note: The ATPC settings should not cause the Rx level on
opposite station to be greater than 20 dBm.(Rx
overload)

3-35

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5.4 Loopback Control


The loopback function is provided for checking the system quality during
maintenance and/or to quickly isolate a fault location on the PDH and
SDH configuration. The control is performed by the LCT, the PNMT or
the PNMS.
Provided here is the control of the:
Near-End loopback (STM-1/E1/E3 LB1) is performed at the STM-1
INTFC/( )E1/E3 INTFC module ((a) in Fig. 3-5) for STM-1/E1/E3
signal.
Far-End loopback is performed at the STM-1 INTFC/( )E1/E3
INTFC module at the opposite end station ((b) in Fig. 3-5) for STM1/E1/E3 signal.
IF loopback (IF-LB) is performed at the MODEM module ((c) in Fig.
3-5) for IF signal.
Notes: 1. During the IF loopback is in execution, monitoring of
the opposite and the subsequent stations are disabled on
the PNMS and PNMT.
2. Loopback control will interrupt the radio link condition.
3. The IF LOOPBACK and the RX SW is not operated
interlock. The RX SW switching is necessary to select
the same CH with IF LOOPBACK in 1+1 configuration.
4. Far-End loopback control in XC in the terminal is
available but there is not control menu from the LCT for
2-WAY PDH.
OPPOSITE STATION

OWN STATION
ODU

IDU
STM-1/E1/E3
CODE
DATA
CONV
IN

MUX

MOD

TX

(a)
STM-1/E1/E3
CODE
DATA
CONV
OUT

DEMUX

LCT/
PNMT

CTRL

DEM

RX

DEM

RX

STM-1/E1/E3
DATA
OUT

(b)

TX

MOD

MODEM

MUX

( )INTFC

Note: Reverse direction is the same as above.


Fig. 3-5 Loopback Location

3-36

CODE
CONV

DEMUX

(c)

MODEM

( )INTFC

IDU

ODU

CODE
CONV

STM-1/E1/E3
DATA
IN

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5.5 Link Loss Forwarding Control (LAN and Link Down for VLAN)
Link Loss Forwarding (LLF) control provides two kinds of functions for
10/100BASE-T interface. One is to automatically stop the output from the
LAN port to alert the equipment connected with the LAN port when the
system has been disconnected by the fault in the radio section. The other is
to transmit the information for cutting the link interconnected with the
LAN port in the opposite station when the link between the LAN port and
equipment is faulty. This function can be selected by setting
Provisioning on LCT to Enable or Disable.
AUTO: Output Stop
Radio Fault

FAULT

HUB

LAN

LAN

HUB

PASOLINK NEO

3.5.6 MS-AIS Generation (SDH)


When any fault occurs in PASOLINK NEO equipment, or when STM1input signal disappears, or when any fault occurs in radio section, The
function of MS-AIS Generation causes the STM-1 output signal from
PASOLINK NEO equipment to be stopped and/or non-frame signal (all
1) to be output, to detect the fault in the MUX equipment of the opposite
station.

MUX

DATA
IN

PASOLINK

PASOLINK

DATA
OUT

MUX

RADIO SECTION

This function can be selected by setting Provisioning on LCT to


Enable or Disable. Normally, this function is set to Enable. If this
function is set to Disable, the function of MS-AIS Generation is stopped.

3-37

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

For example, at the station A, when the PASOLINK NEO equipment


detects the STM-1 input Loss Of Signal (LOS) and/or Loss Of Frame
(LOF), the information is transmitted to the station B by using RFCOH.
When the station B detects the information, PASOLINK NEO equipment
stops the STM-1 output signal. Similarly, it is the same even if a receiving
input level down or loss of radio frame (LOF) appear in station B.
STATION A

STATION B

PASOLINK NEO
STM-1
INPUT

STM-1
INTFC
INPUT
LOSS

MODEM
RFCOH
MUX

PASOLINK NEO
MODEM
ODU

ODU

FSYNC

STM-1
OUTPUT

STM-1
LOF

LOF
LOS
LOF

STM-1
INTFC

RFCOH
DEMUX

RFCOH

RLOS/RLOF

STM-1 OUTPUT CONTROL

Station A

Station B
LCT

Event

STM-1
OUTPUT

LED

LCT

LED

STM-1 Output
Control

STM-1 Input Loss at


Station A

IDU ALM

MAIN INTFC
LOS

Under Execution

Shutdown *
(or all 1)

STM-1 Loss of
Frame at Station A

IDU ALM

MAIN INTFC
LOF

Under Execution

Shutdown *
(or all 1)

RX Level Down

N/A

ODU ALM Under Execution

Shutdown *
(or all 1)

Loss of Radio
Frame at Station B

N/A

IDU ALM

Under Execution

Shutdown *
(or all 1)

BER Degrade
(1E-4) at Station B

N/A

IDU ALM

Normal

N/A

Notes:1. * Optical interface: Shutdown


Electrical interface: all 1
2. When the MS-AIS Generation is Enable, status indication of
MS-AIS Generation on LCT is not indicated.

3-38

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5.7 Cross Polarization Interference Canceller (XPIC) Reset Control


For the Cross Polarization Interference Canceller (XPIC) to function
properly, signals for both Main Master and Sub Master sides must be
received normally. For this reason, when either signal is in abnormal
condition, the XPIC RESET function provides a way for turning off the
XPIC operation. Local/Remote XPIC reset can be controlled separately to
the Main Master and Sub Master.

Control

OPPOSITE STATION

LOCAL STATION

Main Master CH

Remote XPIC reset V-pol


STM-1-1

ODU

IDU

XIF

STM-1-2

IDU

coincidence

V-pol

Dual Pol.
f1
f2
f1
f2

OMT

ODU

H-pol

coincidence

Remote XPIC reset H-pol

Note:

V-pol

ODU

IDU

STM-1-1

Local/Remote XPIC
reset V-pol
XIF

OMT

REMOTE
Local/Remote XPIC
reset H-pol

H-pol

ODU

IDU

STM-1-2

Sub Master CH

Feeder Connection for Dual Pole Feed Antenna.

Fig. 3-6 XPIC Reset Control

The LOCAL RESET and/or REMOTE RESET control is performed to the


channel which is working online when the system is following conditions.
When the MODEM or ODU is replaced.
Frame Synchronization is lost (FASYNC) at the MODEM module in
the Co-pol. channel.
At the MODEM module in the Co-pol. channel, IF signal from X-pol.
channel is lost (XIF alarm).
The system is controlled in IF loopback (IF-LB) condition with the
LCT, PNMS or PNMT.
The XPIC RESET control is executed from the LCT, PNMS or
PNMT.
The XPIC RESET control is applied from the MODEM module in
the X-pol. channel.
The XREF or LO REF alarm condition occurs.
Note: The SD system can not be applied for the XPIC configuration.

3-39

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5.8 Network Management (Optional)


The Network Management System (NMS) configuration is shown in Fig.
3-7. The PASOLINK network management system (PNMS) is connected
to the NMS (LAN) connector of the IDU located at the designated
maintenance center while the PASOLINK network management terminal
(PNMT) is connected to the LCT USB connector on the IDU of remote
stations. The PNMT/PNMS provides monitoring and control of the actual
microwave link status and its associated PASOLINK NEO equipment.
Status information form and control signals to remote stations are
transmitted using RFCOH (SDH) or SC CH (PDH).
For detailed information, refer to the related PNMS or PNMT manual.

PASOLINK
NEO

PASOLINK

NEO
NMS (LAN)
Connector

PNMS

LCT
Connector

PNMT
PNMS : PASOLINK Network Management System
PNMT : PASOLINK Network Management Terminal
Fig. 3-7 Network Management System

*including VLAN

3-40

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.5.9 Functionality Classification


The functionality of the PASOLINK NEO is defined by optional system
parameters, interface card and transmission capacities as listed in the
following categories. The functionality is found in the Software Key in the
LCT Inventory menu.

Functionality Classification of the PASOLINK NEO


1

Capacity
and
Redundancy

Bit Rate

LAN Interface

XPIC
Functionary

1+0 System

1+1 System

Fixed

Available

Available

1. 10 MB

1. 10 MB

Free

Unavailable

Unavailable

2. 20 MB

2. 20 MB

3. 40 MB

3. 40 MB

4. 80 MB

4. 80 MB

5. 100 MB

5. 100 MB

6. 156 MB

6. 156 MB

Optional System, Interface Card and Transmission Capacity


System and Transmission Capacity
1+0
16E1 + 2P LAN
(STANDARD)

10MB 20MB 40MB 80MB

10MB 20MB 40MB 80MB

16E1 + 2P LAN
(2-WAY/XC) *1

10MB 20MB 40MB 80MB

10MB 20MB 40MB 80MB

40MB 80MB

40MB 80MB

E3
Interface
Cards

1+1

32E1 + 2P LAN

10MB 20MB 40MB 80MB 100MB 10MB 20MB 40MB 80MB 100MB PDH

48E1

10MB 20MB 40MB 80MB 100MB 10MB 20MB 40MB 80MB 100MB

4E1 + 4P LAN*

10MB 20MB 40MB 80MB 100MB 10MB 20MB 40MB 80MB 100MB

STM-1 Ele

156MB

156MB

STM-1 Opt S1.1

156MB

156MB

STM-1 Opt L1.1

156MB

156MB

2P LAN

156MB

156MB

GbE*

156MB

156MB

SDH

Note: *1:2-WAY/XC; Available/Unavailable

3-41

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.6 Protection Switching


Protection switching is provided in the 1+1 Twin-path and the HS systems.

3.6.1 1+1 Twin-path System


Protection switching in this system is performed by a hitless switch (HL
SW) on the ( )INTFC module of the IDU at the receiving end.
When both the No. 1 and No. 2 channels are in normal operating
condition, the STM-1/E1/E3 data streams from the associated MUX
equipment are sent to the receiving end through the No. 1 and No. 2
channels. At the receiving end, the output data streams of the No. 1 and
No. 2 channels MODEM enter the HL SW. The data signal selected by HL
SW is fed to associated MUX equipment.
At the receiving end, when the low bit error alarm (LOW BER ALM) is
detected in the MODEM of the No. 1 channel, the alarm signal is sent to
the switch control logic circuit on the CTRL module. The switch control
logic circuit send the HL SW control signal to the ( ) INTFC module.
Then, the HL SW selects the data signal from No.2 channel. The switching
condition is shown on the RX1 and RX2 STATUS indicators on the IDU.

3.6.2 Hot-standby System


Protection switching in this system is performed by the TX switches* on
the No. 1 and No. 2 channel ODUs at the transmitting end and by the HL
SW on the ( ) INTFC module of the IDU at the receiving end.
Note: *Transmit switching is actually accomplished by muting the
output of either No.1 or No.2 channel ODU, using a control
signal from the IDU.
When both the No. 1 and No. 2 channels are in normal operating
condition, the STM-1/E1/E3 data signal from the associated MUX
equipment are sent to the No. 1 and No. 2 channel ODUs through the No. 1
and No. 2 channel IDUs. Here, either of the No. 1 or No. 2 channel signal
is selected at the TX switch on the ODU and fed to the receiving end. At
the receiving end, the output data signal of the No. 1 and No. 2 channels
MODEM enter the HL SW on the ( ) INTFC module. The data signal
selected by HL SW is fed to associated MUX equipment.

3-42

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

When the modulator alarm is detected in the MODEM or when the TX IF


input alarm, TX power alarm or APC alarm is detected in the ODU, the
alarm signal is sent to the switch control logic circuit on the CTRL
module. The switch control logic circuit produces a TX switch control
signal for selecting the ODU that is in the normal condition. When the
ODU receives the TX switching control signal, the output of the ODU that
is currently active (on-line) is muted and the output of the other ODU is
un-muted. The switching condition is shown on the TX1 and TX2 STAUS
indicators on the IDU.
At the receiving end, when the low bit error alarm (LOW BER ALM) is
detected in the MODEM of the No. 1 channel, the alarm signal is sent to
the switch control logic circuit on the CTRL module. The switch control
logic circuit send the HL SW control signal to the ( )INTFC module. Then,
the HL SW selects the data signal from No.2 channel. The switching
condition is shown on the RX1 and RX2 STATUS indicators on the IDU.
Three mode of TX switch protection controls are provided in Hot Standy
system.
(1) TX SW Lock in Control
Under TX SW setting for No.1 priority mode, TX SW Lock in function
inhibits selecting back to No.1 for a preset duration (Lock in hold time)
when switching occurs a few times within a short period. If No.1 system is
kept in normal condition more than 24 hours without any alarm, the Lock
in hold will be released automatically.
(2) TX SW Reverse Function Control
If no signal is received on both No.1 and No.2 system more than 2 minutes
according to some problem on the opposite station's transmitter, TX SW
Reverse function will request to switch over the transmitter of the opposite
station. This function is available under TX SW setting for Non Priority
mode.
(3) TX SW Sensitivity Control
TX SW Sensitivity function provides to make shorter the ALM detection
period for TX Switching in order to reduce the switching time.

3-43

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.6.3 Switchover Control


The following explains the protection switching function in the 1+1 Twinpath and HS system.
(a) TX Switching
TX switching in HS system is accomplished by muting the TX
output power of either No.1 or No.2 channel ODU. Two mode of
TX switch controls are provided: automatic switching that is
initiated by detection of a failure in the transmit section of the IDU
or ODU, and manual switching is performed by using the LCT. TX
switching, either manually or automatically, may cause a
momentary interruption of the traffic. TX switching have the
following operational mode:
Switching Mode:
1. Manual: Applied in Maintenance mode.
2. Auto: Normal operating mode.
TX SW Setup in provisioning has following features:
Switching Priority:
1. Non Priority: Selecting non revertive mode.
2. Priority No.1: This mode is applied to select No.1
when both No.1 and No.2 are normally operating.

3-44

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

(b) RX Switch
RX switching in 1+1 Twin-path/HS system is performed by the HL
SW on the ( ) INTFC module.
Two types of RX switch controls are provided: automatic
switching that is initiated by the quality deterioration of the
received signal and manual switching that is initiated by the
operator using the LCT.
The switching mode and switching priority for automatic and
manual switching are identical to those of TX switching. However,
the switching priority is only valid under automatic switching
control. This is because automatic switching is implemented by
hardware logic and manual switching is implemented by software
logic. That is, automatic switching and manual switching are
completely independent and separate operations. Thus, when the
operator reverts to automatic switching after performing manual
switching, the channel will be re-selected by the switch control
logic circuit.
Switching Mode:
1. Manual: Applied in Maintenance mode.
2. Auto: Normal operating mode.
RX SW Setup in provisioning has following features:
Switching Priority:
1. Non Priority: Selecting non revertive mode.
2. Priority No.1: This mode is applied to select No.1
when both No.1 and No.2 are normally operating.
RX SW Maintenance Mode:
1. Manual mode, this disables the RX SW manual control
when either No. 1 or No. 2 RX route is in alarm status.
2. Forced mode, this enables the RX SW manual control
though either or both No. 1 and No. 2 RX routes are in alarm
status.
Caution: When the RX SW mode is set to Forced in
provisioning, RX SW manual control can select either
No. 1 or No. 2 RX route though one is alarmed. Then,
take care switching to avoid traffic interruption.RX
SW Condition-Early Warning
1. Included Early Warning, this switch over the RX SW at
less than 1E-9.

3-45

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

2. Excluded Early Warning, this switch over the RX SW at


Low BER setting values 1E-6, 1E-7, 1E-8 or 1E-9.
(default value is 1E-7)

3.7 2-WAY/XC Function


The 2-WAY function is available to perform E1/LAN signal transmission
in two different directions with one IDU and the Cross-connect function to
connect the E1/LAN signals to the desired direction by the installation of
16E1 INTERFACE module which is composed of 2-WAY/XC PKG (E/W
LAN).
For the details, refer to the 2-WAY/Cross-connect Function Application
and Setting in the Section IV Appendix.

3.8 VLAN Function


This equipment supports four types of VLAN
1. Port -based VLAN
The VLAN group can be created among four LAN ports and
the DMR ports. The maximum number of LAN ports for this
group is eight.

2. TAG LAN
VLAN ID (VID) is used for group identification which is
identify from the incoming packets. Packets can be sent/
received in the same group.
Acceptable VID range: 1 to 4094
Maximum number of VID: 64 groups.
Each VID allow incoming data without TAG or discard/
forward data by TAG addition

3-46

Submission Prohibited
NEC Internal Use Only
ROI-S05749

SYSTEM SETUP

3. Port-base + TAG VLAN


This converge the two methods, port-based grounding VLAN
function is added on TAG VLAN. IF Port group is mismatch,
the packets will not be send/received even if the VID is assigned.
Maximum number of Ports groups: 8groups
VID range: 1 to 4094
Maximum number of VIDs groups: 64groups

3-47

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

4. Double TAG VLAN


Making group by adding equipment specific TAG at AIR
section. This function can support both, TAG-attached
or none TAG-attached traffics. TAG deleting from
outgoing traffic is supported.
VID range: 1 to 4094
Maximum number of VIDs groups: 64 groups

3-48

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

VLAN Types for VLAN Interface Cards


(1)

(2)

Port VLAN

TAG VLAN

Interface Card

(a)

4P LAN INTFC-E

(b)

GbE INTFC-E

(3)
Port + TAG
VLAN

(4)
Double
TAG VLAN

Note: For GbE application, transferable packet size is different from


Port1 (Gigabit) to Port2-4 (10/100BASE-TX). When you set a
group between port2-4, receiving packet size should carefully
checked. (The packets which size is mismatched, will be deleted.)
Note: Multicast frame transmission is different depending on the FPGA
version.

H3022A 4P LAN INTFC-E FPGA Version


H3022B,C GbE INTFC-E FPGA Version

OLD
3.03 or less
3.03 or less

NEW
3.04 or more
3.04 or more

Multicast frame(01-80-C2-00-00-02 to 0F) Drop

Note: When VLAN is used, it is necessary VLAN=1 (default value) must


be present in order for the VLAN to work.

3-49

Submission Prohibited
NEC Internal Use Only
SYSTEM SETUP

ROI-S05749

3.9 QoS Functions


This equipment provides three types of QoS:
1. IEEE802.1q QoS
Date is transferred according to four-level priorities (VLAN
tag) in MAC frame.
Priority: Queues priority is set by using User Priority field.
The priority level is four is levels, PQ3(High)-PQ0(Low).
Scheduling:For Weighted Round Robin/Strict Priority+WRR,
it has four weighting levels(PQ3-0).
For Strict Priority+WRR, PQ3 becomes strict (first) priority
regardless of its weighting level.
2. DSCP (Differentiated Services Code Point): Data is
transmitted according to four-level priority, 6bits
of ToS (Type of service) 8bits field re-defined by Diffserv
architecture in the header of IP packet.
Priority: Queues priority is set by using DSCP.The priority
level is four levels, PQ3(High)-PQ0(Low).
Scheduling:For Weighted Round Robin/Strict Priority+WRR,
it has four weighting levels (PQ3-0). For strict (first) priority
regardless of its weighting level.
3.ToS: Date is transmitted according to four-level priority, precedence value (8-grade) of ToS field in the header of IP
packet.
Priority: Queues priority is set using ToS field. The priority
level is four levels, PQ3(High)-PQ0(LoW).
Scheduling: For Weighted Round Robin/Srict Priority+WRR,
it has four weighting levels(PQ3-0). For Strict Priority
PQ becomes strict(first) priority regardless of its weighing
level.
Qos supporting
Interface Card

(a)

4P LAN INTFC-E

(b)

GbE INTFC-E

3-50
50 pages

(1)
IEEEE802.1q
CoS

(2)
DSCP

(3)
ToS

Вам также может понравиться