Академический Документы
Профессиональный Документы
Культура Документы
DAR
PA/LC
(HLURB)
DP/FA
(HLURB)
BLDG.
PERMIT
(OBO)
ECC
(DENR)
Condo
Cert. of Title
(RD)
COC
Certificate of Completion
(HLURB)
License
to Sale
(HLURB)
Registration
(HLURB)
ISSUANCE
OF
DEVELOPMENT PERMIT
FOR
CONDOMINIUM
SPACE ALLOCATION
Floor Area Requirement
a) Single Occupancy Unit
Single Occupancy units shall have a
minimum floor area of 18 square meters,
however, a net floor area of 12 square meters
is allowed with the following limitations:
intended for students/employees/workers
the condominium project is within highly
urbanized areas.
SPACE ALLOCATION
With basic facilities/amenities:
Laundry/amenities
visitors lounge
dining area
Other measures to ensure compliance with
the intended use of the unit to be explicitly
indicated in the Master Deed/Contract to Sell
SPACE ALLOCATION
Floor Area Requirement
b) Family Dwelling Unit (For PD 957)
The minimum floor area of family condominium
units shall be 36 square meters and 22 square
meters for open market and medium cost
condominium project respectively.
For BP 220 condominium projects, the minimum floor area shall be 18 square
meters.
SPACE ALLOCATION
Parks/Playground and/or Other Recreational Areas
Parks/Playground (exclusive of easements, access
roads, driveways, parking space) shall be required for:
Projects with a gross saleable area of 1,000
square meters; or
Projects with ten (10) or more condominium
units.
The minimum area for a single park/playground
shall be 50 square meters. Increments of 3.00
square meters for every additional family
dwelling type in excess of 10 units shall be
added.
SPACE ALLOCATION
1. Service Area (Laundry/ Drying Area)
Common if not integrated with
each unit
2. Reservoir / Water Tank
20% Average Daily Demand (150lcpd) plus Fire Reserve (5,000
liters).
3. Refuse Collection / Disposal
Centralized garbage depository area &
efficient refuse collection & disposal
services shall be provided .
MECHANICAL
(ELEVATOR REQUIREMENT)
P.D. 957
Section 1302 Mechanical Regulation (IRR,
NBC) 5.1 In apartment or residential
condominium of five (5) storeys or more, at
least one (1) passenger elevator shall be kept
on twenty-four (24) hours constant service.
MECHANICAL
(ELEVATOR REQUIREMENT)
B.P. 220
(Amended per Board Res. No. 824, Series of 2008)
PARKING
Off-street Parking shall be provided per Revised
IRR/NBC as follows:
Multi-family living unit regardless of the number
of storey with average living unit floor areas:
18 sq.m. to 22 sq.m.
1 slot/ 8 living units
up to 50 sq.m.
1 slot/ 6 living units
51 sq.m. to 100 sq.m.
1 slot/ 4 living units
more than 100 sq.m.
1 slot/ living units
For BP. 220 Condominium Project: 1 slot/ 8 living
units. Perpendicular/ Diagonal Parking- 2.5 m. x 5
m, or Parallel parking -2.15 m. x 6 m.
PARKING
Off-Site Parking
May be allowed provided that it will form part of
the project & shall be located not more
than
100 meters away from project site.
(For Commercial 200 meters).
NOTE: Compliance with additional parking
spaces as required by local ordinances shall
be mandatory.
1.
2.
3.
4.
ISSUANCE
OF
CERTIFICATE OF
REGISTRATION
&
LICENSE TO SELL
FOR
CONDOMINIUM
I. E V A L U A T I O N P R O P E R
a. Documents Required
1. REGISTRATION STATEMENT
Name of Applicant
Capitalization
Project Name
Location
Area
Transfer Certificate Title (TCT) Number
4. ARTICLES OF INCORPORATION
5. COPY OF BROCHURES, ADVERTISEMENT
MATERIALS
6. COPY OF CONTRACTS TO BE USED
7. AFFIDAVIT OF WILLINGNESS TO CHANGE
NAME OF PROJECT
8. ENVIRONMENTAL COMPLIANCE
CERTIFICATE
common
THANK YOU !