CLFE(X)COAX
Ethernet-over-Coax Extender
with Pass-Through PoE
The ComNet CopperLine CLFE(X)COAX Ethernet over COAX line consists of four
models that support 100Mbps Ethernet as well as Pass-through Power over Ethernet
(PoE) over standard 75 coaxial cable. These models support transmission distances
of up to 5,000 feet (1524m) at 10 Mbps, or 1800 feet (548m) at 100 Mbps. The
CLFE1COAX, the CLFE4COAX, CLFE8COAX and the CLFE16COAX transport, one, four,
eight or sixteen channels respectively. The IEEE 802.3-compliant extenders also
meets the requirements for IEEE 802.3af PoE power, passing through up to 30 watts
of power per port to the powered device (PD). The CLFE(X)COAX series may also be
used interchangeably with other CopperLine Ethernet-over-Coax extenders.
Environmentally hardened to the requirements of NEMA TS-1/ TS-2 for most out-of-plant
applications, and true plug-and-play design ensures ease of installation and operation.
LED indicators are provided for rapidly ascertaining the operating status of the
device. See Figures 7 and 8 on Page 7 for LED explanations.
Packaged in a rugged aluminum housing, these units are designed for desktop or standalone mounting. The CLFE8COAX and CLFE16COAX are offered in EIA 19 1U high rack for
easy installation. See Figures A through C on Page 8 for mounting instructions.
See Figures 1 8 for complete installation details.
INS_CLFEXCOAX_REV
09/28/11
PAGE 1
CLFE(X)COAX
FIGURE 1 CLFE1COAX
CAT5/6
COAX (75)
Power Supply
Connection
via external power adaptor
Optional, if there
is no power supply
connected to the unit
it will try to detect PoE.
FIGURE 2 CLFE1COAX
LEFT PANEL
RIGHT PANEL
Note: Center
pin on power
connector is
positive (+).
Ground
Screw*
FIGURE 3 CLFE4COAX
LEFT PANEL
COAX (75)
RIGHT PANEL
Ground
Screw*
CAT5/6
INS_CLFEXCOAX_REV
09/28/11
PAGE 2
CLFE(X)COAX
Input with
external power
plug installed.
External
power adapter
(included)
INS_CLFEXCOAX_REV
09/28/11
PAGE 3
CLFE(X)COAX
FIGURE 4 CLFE8COAX
COAX (75)
COAX (75)
CAT5/6
CAT5/6
Ground Screw*
FIGURE 5 CLFE16COAX
COAX (75)
COAX (75)
COAX (75)
CAT5/6
CAT5/6
CAT5/6
CAT5/6
Ground Screw*
* Warning: A ground connection is
required for the surge protection to
work. Failure to ground properly voids
the warranty and may cause damage.
INS_CLFEXCOAX_REV
09/28/11
PAGE 4
CLFE(X)COAX
NVR
PoE Switch
CNGE2FE24MSPOE
CLFE1COAX
5,000ft
(1524m) Coax
CLFE1COAX
328ft
(100m) Cat-5
PoE Camera
CLFE1COAX
328ft
(100m) Cat-5
PoE Camera
CLFE16COAX
PoE Switch
CNGE2FE24MSPOE
NVR
CLFE16UTP
CLFE16COAX
NVR
IP Cameras
CLFE4US1TPC
328ft
(100m) Cat-5
IP Cameras
PoE Switch
CNGE2FE24MSPOE
NVR
CLFE1UTP
Data + Power
CLFE1UTP
Data +Power
CLFE16IPS
CLFE1COAX
PoE Camera
CLFE1COAX
PoE Camera
INS_CLFEXCOAX_REV
09/28/11
PAGE 5
CLFE(X)COAX
Ethernet Switch/NVR-end
Installation (CLFE(X)COAX)
INS_CLFEXCOAX_REV
09/28/11
PAGE 6
CLFE(X)COAX
TRAFFIC (Extended)
10/100BaseT
GREEN
Connection is OK,
10BaseT mode
YELLOW
RED
Power is on
Connection is OK,
100BaseT mode
OFF
Power is off
No traffic
Flashing Connection is
OK with traffic
YELLOW
RED
OFF
Connection is OK
No connection
No connection
INS_CLFEXCOAX_REV
09/28/11
PAGE 7
CLFE(X)COAX
Installation Considerations
The CLFE1COAX and CLFE4COAX are supplied as Standalone modules. The
CLFE8COAX and CLFE16COAX can be installed as Standalone modules
or can be rack-mounted with the addition of the provided 19-Inch RackMounting Ear Brackets.
Figure A
Dimensions are for the CLFE1COAX standalone ComNet module
1.15" (30mm)
1.6" (40mm)
1.6" (40mm)
4.73" (120mm)
Figure B
Dimensions are for the CLFE4COAX standalone ComNet module
1.6" (40mm)
3.3"
(84mm)
3.6" (92mm)
Figure C
Dimensions are for the CLFE8COAX and CLFE16COAX ComNet modules
3.25"
(82.5mm)
17" (432mm)
1.75"
(44.5mm)
INS_CLFEXCOAX_REV
09/28/11
PAGE 8
IMPORTANT SAFEGUARDS
Read and keep these directions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with a dry cloth.
Install in accordance with the manufacturers instructions.
This installation should be made by a qualified service person and should
conform to all local codes.
DO NOT bundle UTP or Coax signals in the same conduit as high-voltage
wiring.
To reduce the risk of fire or electrical shock, do not expose these products
to rain, moisture, dripping or splashing.
No objects filled with liquids, such as vases, shall be placed on the
equipment.
DO NOT install the unit in a place where the operating ambient
temperature exceeds 75C.
Make sure that the external power supply output voltage is in the
recommended range.
Do not install near any heat sources such as radiators, heat registers, stoves
or other apparatus (including DVRs) that produce heat.
Protect the power cord from being walked on or pinched, particularly at
the power source, convenience receptacles and the point where they exit
from the apparatus.
WARNING: To reduce the risk of fire or electric shock, do not expose this
apparatus to rain or moisture. This apparatus shall not be
exposed to dripping or splashing and no objects filled with
liquids, such as vases shall be placed on the apparatus.
WARNING: This apparatus is a Class I product. This product must be
connected to a mains socket outlet through an AC to DC
power supply.
WARNING: The mains plug is used as the disconnect device and shall
remain readily operable.
WARNING: F or non-PoE applications, unit is to be connected to a mains
socket outlet through a Listed Class I power supply rated
12 VDC or 24 VAC.
INS_CLFEXCOAX_REV
09/28/11
PAGE 9