Вы находитесь на странице: 1из 4

Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Flow chart: Fixed column bases


This flowchart describes the design procedure for a fixed column base connection.

Start

Column dimensions
Design forces
Nc,Ed, Mc,Ed, Vc,Ed
Base plate
dimensions
known?

Concrete class
Base plate steel grade
Anchor bolt class

No

Determine base plate dimensions


based on design compression
force Fc,Ed

Yes

Created on Monday, January 22, 2007


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

Base plate
dimensions

Anchor bolts
dimensions
known?

Determine anchor bolt dimensions


and base plate thickness for
design tension force Ft,Ed

No

Anchor bolt
diameter
Plate thickness

Yes

Verify joint for combined


MEd and NEd for all load
combinations

SN043 5

Mc,Ed Mj,Rd ?

No

Modify base design

SN021
Yes

Calculate shear
resistance

SN037

Modify base design for


shear resistance

No

Fv,Rd

Vc,Ed Fv,Rd ?

Yes

End

Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Determination of base plate dimensions, based on compression force

Start
Design forces at
column base
Concrete class

SN043
4.3

Created on Monday, January 22, 2007


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

SN043
4.3

Calculate maximum
compression force acting
on the foundation

Fc,Ed

Determine base plate


dimensions

Dimensions
tp, hp, bp

Return

Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Determination of anchor bolt dimensions

Start
Design forces at
column base

Created on Monday, January 22, 2007


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

Base plate details


Concrete class
Bolt class

SN043
4.3

Calculate maximum
tensile force on the
foundation

Ft,Ed

SN043
4.5.1, 4.5.2

Determine anchor bolt


dimensions and required
base plate thickness

Bolt diameter
Base plate
thickness tp

Return

Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Quality Record
RESOURCE Title

Flow chart: Fixed column bases

Reference(s)
ORIGINAL DOCUMENT
Name

Company

Date

Created by

Ivor Ryan

CTICM

07/02/2006

Technical content checked by

Alain Bureau

CTICM

07/02/2006

1. UK

G W Owens

SCI

23/5/06

2. France

A Bureau

CTICM

23/5/06

3. Sweden

B Uppfeldt

SBI

23/5/06

4. Germany

C Mller

RWTH

23/5/06

5. Spain

J Chica

Labein

23/5/06

G W Owens

SCI

21/8/06

Editorial content checked by

Created on Monday, January 22, 2007


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

Technical content endorsed by the


following STEEL Partners:

Resource approved by Technical


Coordinator