Вы находитесь на странице: 1из 17

Escorrenta superficial

Mtodo racional

Q=

CIA 3
m / seg
360

Donde:

I= mm/h (intensidad)
A = Ha (rea)
C= Coeficiente de cobertura

C 1A 1+C 2A 2+C 3A 3 .. CnA n


A 1 + A 2+ A 3+ A n

METODOS PARA CALCULAR TC

ROWE
3

0.86L3
t c=
, horas
H
Si:

L = KM
H= m

METODOS PARA CALCULAR TC

KIRPICH

3.2808L
t c =0.0078
0.5
S

0.77

, Min

Si:

L=m
S = H/L pendiente

Aplicacin de teora sobre drenaje pluvial

80

90.10

80

90.05
50

90.15
4

10

100

89.85

89.80

89.70

89.90
6

7
220

10

90.15

120

10

89.60

89.40

89.60
8

89.50

12

100

100

89.65

89.70

11

10

89.50

10

88.80
80

80

50
14

13

88.70

Ca

15

88.80

Calculo de tiempo de concentracin


El clculo de tiempo de concentracin lo aremos por los dos mtodos ya explicados anteriormente (mtodo ROME y mtodo
KIRPICH)

INIC
IO
1
1
1
4
4
6
9
10
12
12

CALCULO DEL TIEMPO DE CONCENTRACION


DIFERENC
ELEVACIO ELEVACIO
LONGIT
IA DE
N >
N <
UD (mt)
COTAS
m.s.n.m
m.s.n.m
(m)

RECORRIDO
Recorrido
1
Recorrido
2
Recorrido
3
Recorrido
4
Recorrido
5
Recorrido
6
Recorrido
7
Recorrido
8
Recorrido
9
Recorrido
10

1
0

1
4

1
4

1
3
1
4

1
5
1
6 7
0
1 1
9
0 4
1
1
11
0
5
1
8 9
2
1 1 1
2 3 4
4 11

1
0
1
4
1
4

1
4
1
3

1
0

1
3

1
4

Tc
S

ROME
(hr)

KIRPICH
(min)

480

90.15

88.70

1.45

0.00302

0.35034

21.09143

640

90.15

88.70

1.45

0.00227

0.48842

29.40426

480

90.15

88.70

1.45

0.00302

0.35034

21.09143

370

90.15

88.70

1.45

0.00392

0.25938

15.61512

370

90.15

88.70

1.45

0.00392

0.25938

15.61512

300

89.90

88.70

1.20

0.00400

0.21896

13.18224

180

89.65

88.70

0.95

0.00528

0.13280

7.99494

200

89.60

88.70

0.90

0.00450

0.15314

9.21946

360

89.70

88.70

1.00

0.00278

0.28994

17.45534

160

89.70

88.70

1.00

0.00625

0.11364

6.84160

MAYOR

0.48842

29.4042
6

29.30517
662
Para el clculo tomaremos como referencia el tc de 29.404 minutos que sale del clculo aplicando en mtodo de kirpic

Intensidad de precipitacin (PAZABAR)


A. Para intensidad de presipitacion usaremos el mtodo de SOIL CONCERVATION
SERVICE ( SCS)
Donde :

I TR =

P 24 : mm

0.280049P MAX 24 ,TC


t c0.6

t c : horas
I tr

: mm/h

GUMBEL
TIEMPO DE RETORNO
5

10

25

50

100

F(Y)

0.800

0.900

0.960

0.980

0.990

1.500

2.250

3.199

3.902

4.600

PRESIPITACION

75.245

96.458

123.260

143.123

162.880

TIEMPO DE RETORNO
PRECIPITACION

10

25

50

100

75.245

96.458

123.260

143.123

162.880

61.493169

69.981635

TIEMPO DE CONCENTRACION
INTENSIDAD

32.329122

0.490 h
41.443179

52.958810

I-D-T
TIEMPO DE RETORNO
DT=T

10

25

50

100

93.59

119.97

153.31

178.01

202.59

10

61.75

79.15

101.15

117.45

133.66

15

48.41

62.06

79.30

92.08

104.79

20

40.74

52.22

66.73

77.48

88.18

25

35.63

45.68

58.37

67.78

77.13

30

31.94

40.94

52.32

60.75

69.14

60

21.07

27.01

34.52

40.08

45.61

120

13.90

17.82

22.77

26.44

30.09

240

9.17

11.76

15.03

17.45

19.85

CURVAS I-D-T
250.00

200.00

I-D-T 5

150.00

I-D-T 10
I-D-T 25

IINTENSIDAD (mm/h)

I-D-T 50

100.00

I-D-T 100

50.00

0.00

50

100

150

200

250

TC (min)

Por clculos anteriores se determin que el tc es de 29.404 min y de acuerdo al RNE el tiempo de retorno es de 10 aos, entonces
por medio de interpolacin se determina que la intensidad es de : 41.5050 mm/h

MTODO DE BELL
max 24 TR=10 aos

ptTR =( 0.21ln T R +0.52 )( 0.54t 0.250.50 )p


donde:
h=60
pt=1
max 24, TR=10 aos=0.3862p max 24 h ,TR=10 aos

TR

I=

P
mm
60
t
h

TIEMPO DE RETORNO (TR)

DISTRIB.
GUMBEL

10

25

50

100

75.245

96.458

123.260

143.123

162.880

TR=10 aos

37.2519446

TR=25 aos

47.6029761

TR=50 aos

55.2742382

TR=100 aos

62.9042483

INTENSIDAD REAL :=

INTENSIDAD UNITARIA*(P60',TR=10)

VALORES DE INTENSIDAD REAL

TIEMPO DE RETORNO EN AOS

Dt: min.
10

25

50

100

137.941

210.069

273.610

345.164

10

103.240

157.223

204.779

258.334

15

84.146

128.145

166.905

210.554

20

71.997

109.643

142.808

180.155

25

63.476

96.666

125.906

158.833

30

57.107

86.967

113.272

142.896

35

52.131

79.389

103.403

130.444

40

48.115

73.273

95.436

120.395

45

44.791

68.212

88.845

112.080

50

41.987

63.941

83.282

105.062

55

39.582

60.279

78.512

99.044

60

37.493

57.097

74.367

93.816

65

35.657

54.301

70.726

89.222

70

34.029

51.822

67.496

85.148

75

32.573

49.605

64.609

81.505

80

31.262

47.608

62.008

78.225

85

30.074

45.799

59.652

75.252

90

28.991

44.150

57.504

72.543

95

28.000

42.640

55.538

70.062

100

27.088

41.251

53.729

67.780

105

26.245

39.969

52.058

65.673

110

25.465

38.780

50.510

63.719

115

24.739

37.674

49.070

61.903

120

24.062

36.643

47.727

60.208

INTENSIDADES - ESTACION PAZABAR


260.000
240.000
220.000
200.000
180.000
Tr= 10 aos

160.000

Tr= 25 aos

140.000
Intensidad :

mm/h

Tr= 50 aos

120.000

Tr= 100 aos

100.000
80.000
60.000
40.000
20.000
0.000
0

15
10

25
20

35
30

45
40

55
50

Tiempo :

65
60

75
70

85
80

95 105 115
90 100 110 120

minutos

Como el RNE nos especifica que todo los clculos para estudios se debe de tener en cuenta que sea un tiempo de
retorno igual a 10 aos

Calculo del c promedio


INTENSIDAD PARA UN TR=
AREA :
10 AOS
m2
Pasf.
DISTRIB.
CALLES Crod.
GUMBEL
C

C*A

TR2000
101900
96.458
2400

0.85

1700

0.85

1615

0.90

2160

Cacalculado con
6000
Intensidad
D.
Gumbel Cb
4050

0.90

5400

0.90

3645

MANZAN Cc
AS
Cd

4050

0.90

3645

6000

0.90

5400

Ce

4000

0.90

3600

Cf

4000

0.90

3600

AREA
TOTAL

34400

TOTAL
Cp

30765
0.89433
14

PtTR =( 0.21ln(10)+ 0.52 )( 0.5429.40.250.50 )37.2520

PtTR =16.72

h
PtTR =( 0.21ln(10)+ 0.52 )( 0.5429.40.250.50 )P t=1
TR=10 aos

h
Pt=1
TR=10 aos =0.386296.458=37.2520

Metodo de F.
BELL
Intensidad

34.122 mm/h

La Intensidad para un Tr= 10 aos es el mayor valor, que es


34.122 mm/h

ESCORRENTA SUPERFICIAL

Q=

Donde:

CIA 3
m /s
360

: Coeficiente de cobertura.

: Intensidad

: Area ( Ha )

C=0.80

( mm/h )

I =34.122 mm/h

A=6.72 Ha

Q=

0.8034.1226.72 3
m /s
360

Q=0.569 m3 /s

CALCULO DE CAUDAL EQUIVALENTE

q e=

( )

Q m
L s.m

Donde:
q e : Caudal unitario
Q

: Caudal total

: Longitud total de pavimento

( mm/h )

q e=

( Ha )
0.9779
l
=0.5015
1950
s.m

RESUMEN
COEF. DE
COVERTURA
0.894
INTENSIDAD
( t=tc=29.4)
34.122 mm/h
AREA
6.72 hect.
CAUDAL TOTAL (QT)
0.569 m3/seg
CAUDAL UNITARIO
0.000292
(qe)
01 m3/s/m
CAUDAL UNITARIO
(qe)
0.292 Lps/m

( )

PLANO FINAL DE LA DISTRIBUCION DE CAUDALES POR TRAMO, LOS VALORES ESTAN DADOS EN L/SEG

23.60

89.80

90.10

30.49

48.667 10

33.334

89.85

90.05

16.60

90.15
4

50

76.29

89.90
6

62.296

89.70
7
220

80

10

29.20

80

100

90.15

80.8

97.57

120

10

100

11

10

89.50

89.65

150.13

89.50

89.60

23.360

34.293

144.293

179.33 10

206.48

100

89.40

89.60

173.626

29.200

89.70

88.80
80

12
23.360

80
13

202.69

50
14

88.70

158.898

15

88.80

Вам также может понравиться