EQUIPMENT
POLHEMUS LIBERTY
FEATURES
Electromagnetic Tracking Based System
Wired System
Update Rate: 240 Hertz per sensor, simultaneous samples
Latency: 3.5 ms
Has distortion sensing capabilities which can warn if the environment is not suitable for data
acquisition.
Compatible with Matlab and LabVIEW. ( Drivers Available)
1.8 mm Micro-sensor
(Polhemus)
Ascension trakSTAR
Visual 3D
Motion Monitor
Visual 3D
Biomechanics Calculations: 3D Kinematics, 3D Kinetics, & EMG. In addition to metrics such as joint
angles, moments, center of pressure, signal filtering, DFT, center of mass, energies, rotations,
volumes, derivatives, and much more you can write your own computations. Full control of
input parameters, Euler angles, rotation order for cardan angles, coordinate systems, and other
parameters make Visual3D the most powerful analysis tool for biomechanics available.
Comprehensive Reporting and Graphing. Graphs can be constrained to events, exported as
images or OpenDoc XML, or correlated to create normative data.
Enables and Supports Complex Analyses. Build custom mathematical expressions within a
pipeline for creating metrics, processing signals, or manipulating data
Real-Time Streaming from systems that can support it.
Real-Time Biofeedback, RT Analysis, RT Pipeline
Induced Acceleration Analysis.
Visual3Ds standard input file is in the C3D format. Visual3D reads and writes C3D files created on
any common computer platform (PC, VAX, SGI, MAC). Tab-delimited ASCII files and Matlabs files
can be imported, exported and converted into C3D files.
A Visual 3D server required for biofeedback and real time streaming and analysis. (an
additional $3000!).
The Server is not able to have Visual3D v5 as a client as that program has it's own dedicated
which in turn uploads them to the biofeedback Server so that it knows what to provide back
to the client.
Data can be exported to Matlab.
Motion Monitor
Compatible with a very wide range of motion capture equipment including Polhemus and
Ascension.
The MotionMonitor is a turn-key 3-D motion capture system designed to synchronously collect data
from kinematic trackers, EMG, force plates, video, event markers and other analog devices.
Event driven triggers for exact start or end of data collection
Autosave/Autoname features for hands-free data collection
Event onset and duration tracked using a choice of hardware switches such as IR, LEDs and FSRs
User defined software switches for contingent start or end conditions
Automatic synchronization of data collected from devices with different sampling rates
Input is the C3D format.
Determine joint centers and segment orientation using accepted protocols such as the Bell, Davis or
Functional methods for hip and shoulder joint centers.
All kinematic and kinetic data are user-selectable from drop-down menus with no programming
required.
New variables can be defined using standard mathematical notation including vector and matrix
operations.
Employ analog filters such as Butterworth and Chebyshev with cut-off frequencies for each sensor
and each analog channel.
Apply user-defined, Dempster or Zatsiorsky anthropometric assumptions.
Scripting functions to facilitate complex data collection.
Post sales support seems to be better than Visual 3D.