B
C
T
(CAN BE COMBINED)
PT
CHF
CHW
T CH
i2
T CH
e2
e2
e2
Mi
Mi
e1
i1
Mi
e1
i1
PT
e1
e2
i2
T CH
PT
PT
Circulation heating
or cooling
i1
i2
e1
i1
SELECTION SOFTWARE
s a v e
y o u r
e n e r g y
N I T
V E N T I L A T O R S
&
H E A T
R E C O V E R Y
14 0 0 t o 10 10 0 B a s i c - N
PERFORMANCE GRAPHS
DUPLEX BASIC-N
DUPLEX Basic-N
Supply air max. 1)
Extraction air max. 1)
Heat recovery efficiency 2)
Number of versions and positions
Weight 3)
Max. power input
Voltage
Frequency
Revolutions
Heating output T max. 4)
Cooling output CHW max. 4)
Cooling output CHF max. 4)
1)
2)
m3h-1
m3h-1
%
kg
kW
V
Hz
min-1
kW
kW
kW
1 400
1 700
1 680
2 400
2 900
2 700
270330
0,6
230
280340
1,2
230
3 400
20
12
11
2 920
27
18
15
3)
4)
5 400
7 100
6 200
8 300
6 000
7 900
up to 75 %
see table Mounting positions, page 4
340410
400470 450550
2,7
4,8
6,5
400
400
400
50
3 000
2 970
2 700
34
51
64
25
35
51
18
31
48
8 100
8 800
8 700
10 100
11 000
10 700
510620
7,7
400
620740
10
400
2 800
76
60
58
2 570
94
68
65
3 400
4 500
4 400
Depending on equipment
Depending on register type, liquid and flow rates
PERFORMANCE SUMMARY
1 000
Supply section (G4, K750.F)
Supply section with T.3+CHW.5+G4 (K750.F)
Supply section with T.3+CHW.5+F7 (K750.F)
Exhaust section (G4, K750.F)
900
800
700
600
500
asi
0B
010 50.F
X 1 3; K7
PLE M11
7 000
8 000
c-N
6 000
DU
5 000
sic-N
4 000
DUP
0 Ba
540 50.F
LEX110; K7
sic-N
3 000
-N
asic
0B
810 50.F
LEX 2; K7
1
sic-N
DUP M1
0 Ba
710 0:F
LEX116; K75
DUP
2 000
0 Ba
340 0.F
LEX109; K75
1 000
DUP
0
0
sic-N
100
200
0 Ba
240 50.F
LEX108; K7
300
DUP
-N
0 Basic
X 140 .F
DUPLEM107; K750
400
9 000
80
70
60
Low limit is without condensation and equal air volume flow (Me = Mi)
1400, 24
0
3400
1400, 2400
5400
71008100
5400
3400
1 000
2 000
3 000
4 000
5 000
10100
7100 8100
50
40
0
10100
6 000
7 000
8 000
9 000
K750.G
K750.F
10 000 11 000 12 000
Air volume (m3/h)
100
80
60
0
0
8100
7100
5400
0
340
40
20
10100
,
1400
1 000
2400
2 000
3 000
4 000
5 000
6 000
7 000
8 000
9 000
DIMENSIONS
BASIC DIMENSIONS
Basic-N Rooftop
400
B
Y
duct extension
1 000
configuration 4/16
(X+100) x (Y+100)
D
400
22
22
i1
XxY
95
X
D
E
e2
XxY
i1
XxY
75
For position 3 / x
105 X x Y
105
22
105
e2
XxY
XxY
XxY
75
22
XxY
Mi
Me
For position 4 / x
XxY
XxY
B
75
DUPLEX Basic-N
Dimension H
Dimension B
Length L
Dimension N
Dimension U
Dimension P
Dimension J
Dimension M
Condensate drain line
Connecting ports
Dimension X x Y
Base frame
Dimension D
Dimension F
Dimension E
Dimension G (between anchoring holes)
Dimension S
Dimension Q
Dimension T
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
1 400
1 605
555
2 560
130
270
135
100
155
2 400
1 605
555
2 560
130
270
135
100
155
3 400
1 605
685
2 560
105
105
105
100
185
5 400
1 605
770
2 560
105
105
105
165
205
32
2 500
1 545
1 228
1 505
795
400
470
2 500
1 545
1 228
1 505
795
400
470
2 500
1 545
1 228
1 505
595
300
370
2 500
1 545
1 228
1 505
595
300
370
Outlet port e2
Outlet port i2
Inlet port i1
Inlet port e1
Y+20
8 100
1 605
1 170
2 560
105
105
105
315
355
95
10 100
1 700
1 390
2 650
105
105
105
340
350
300 x 300 300 x 300 400 x 400 400 x 400 500 x 500 500 x 500 700 x 500
Note: For detailed design and technical data we recommend using our dedicated design software.
X + 20
7 100
1 605
990
2 560
105
105
105
225
265
2 500
1 545
1 228
1 505
395
200
270
2 500
1 545
1 228
1 505
395
200
270
2 590
1 640
1 273
1 600
490
278
287
MOUNTING POSITIONS
Position 3; 4 top view
i2
R O O F T O P U N I T S F L AT
e2
i2
e2
e2
e2
3
4
4
4
e1
i1
i1
i1
i1
e1
i1
i1
PORT CONFIGURATION
i2
i2
i2
e2
e2
e2
3/8*
3/10
i1
e1
3/12*
i1
e1
e1
i1
i2
i2
e2
i2
e2
e2
3/14
3/16
e1
e1
3/17
i1
e1
i1
i1
i2
i2
i2
e2
e2
3/18
e2
3/19
e1
e1
3/20*
e1
i1
i1
i1
i2
i2
i2
e2
e2
e2
4/8*
4/10
e1
i1
4/12*
i1
e1
e1
i1
i2
e2
i2
i2
e2
e2
4/14
4/16
4/17
e1
e1
i1
i1
e1
i1
i2
i2
e2
i2
e2
4/18
e2
4/19
e1
i1
i1
4/20*
e1
i1
e1
HANDLING SPACE
MOUNTING POSITIONS CONNECTIONS THROUGH THE ROOF
HANDLING SPACE
condensate drain line. This line must run through a U-bend at least
150 mm high into a sewer. Handling space in front of the unit must
be maintained for replacing filters.
min. 700
Handling space
min. 700*
min. T
min.
700*
Mi
Me
min. 700
Typ
DUPLEX 1400 Basic-N
DUPLEX 2400 Basic-N
DUPLEX 3400 Basic-N
DUPLEX 5400 Basic-N
DUPLEX 7100 Basic-N
DUPLEX 8100 Basic-N
DUPLEX 10100 Basic-N
T (mm)
600
600
700
800
1 000
1 200
1 400
Type
DUPLEX 1400 Basic-N
DUPLEX 2400 Basic-N
DUPLEX 3400 Basic-N
DUPLEX 5400 Basic-N
DUPLEX 7100 Basic-N
DUPLEX 8100 Basic-N
DUPLEX 10100 Basic-N
Working point
1000 m3/h (200 Pa)
2000 m3/h (200 Pa)
3000 m3/h (200 Pa)
4500 m3/h (200 Pa)
6000 m3/h (200 Pa)
7500 m3/h (200 Pa)
9500 m3/h (200 Pa)
inlet e1
45
62
68
72
71
78
84
unit
61
71
71
72
72
78
66
MODIFICATIONS
DUPLEX BASIC-N BASIC UNIT
Me.xxx; Mi.xxx
Fans
All units are equipped with high-efficiency fans (ebm-papst and Ziehl Abegg) with free-running impellers and backward
curved blades. Whole range of DUPLEX Basic-N units meets the requirements of the European directive ErP 2015.
Heat recovery core
For every single unit size are two heat recovery exchangers available (K750.F and K750.G),
that differs in heat recovery efficiency and pressure loss.
K750.x
B.x
By-pass (B)
By-pass of the plate heat recovery core on supply air side. By-pass consists of an opposed-blade damper
andanactuator.
It is fitted next to the recovery core inside the unit; it does not increase size of the unit.
The standard actuator is BELIMO 24 V; other types are available upon request.
C.x
Mixing damper (C)
The mixing damper is used to mix exhaust and supply air. Circulation valve consists of an opposed-blade damper and
actuator. It is fitted next to the recovery core inside the unit, it does not increase the size of the unit.
The standard actuator is BELIMO 24 V; other types are available upon request.
T.x
H o t w a t e r h e a t i n g c o i l ( T )
Built-in water-to-air three-row (possibly multi-row) heating coil; made of copper pipes and aluminum fins. Designed
forsystems up to 110 C and 1,0 MPa. The coil is standardly equipped with flexible connection and a steam-gas
capillary thermostat for freeze protection. Units in modification T (with heating coil) must be equipped with e1 supply
air shutoff damper; an actuator with spring-return function is reccommended. A coil hydraulic kitforheating capacity
control of RE-TPO4 or RE-TPO3 type can be supplied with the coil upon request.
CHF.x
Direct expansion (DX) coil (CHF)
A built-in coil made of copper pipes and aluminum fins, including a condensate pan with individual condensate drainage
and a pressure switch for freeze alarm. Three- or multi-row coils with various evaporate temperature are chosen
depending on capacity required, refrigerant type and air parameters. Optionally it is possible to deliver double-circuit
evaporator in division 1:1 or 1:2, or completely atypical with needed capacity.
CHW.x
A built-in coil made of copper pipes and aluminum fins, including a condensate pan with individual condensate drainage.
Three- ormulti-row coils are chosen depending on capacity required, cooling medium type and air parameters.
The cooling coil can be equipped with the R-CHW2 or R-CHW3 hydraulic kit on request.
PT.x
Built-in water-to-air three-row heating coil; made of copper pipes and aluminum fins. Designed forsystems up to 110 C
ACCESSORIES
OTHER OPTIONAL ACCESSORIES (BASIC OVERVIEW)
Ke.xxx; Ki.xxx
Shutoff damper e1; i1
Shutoff dampers standardly fitted with BELIMO
actuators are located in the air inlet port.
The following damper types are available:
-- fresh air damper e1 mandatory for C
modification (with mixing damper) and T,
PTmodification (with heating coil)
-- exhaust air damper i1
Fe.xxx; Fi.xxx
Air filtration
All DUPLEX Basic-N units can be equipped with
supply or exhaust air filtration of M5 or F7 class
instead of standard G4 class. Pressure drop of
the filter is then 50 to100 Pa (clean filter)
depending on air flow rate, unit type and dirt
accumulated.
RE-TPO.x
Heating coil
hydraulic kit
Its function is to control heating capacity
ofaheating coil. It consists of a three-speed
pump, two globe shutoff valves and connection
pipes. Further equipment depends on the type:
RE-TPO4 four-way mixing valve with
anactuator for digital control system
RE-TPO3 three-way mixing valve with
anactuator for digital control system
R-CHW.x
Cooling coil
hydraulic kit
Its function is to control cooling capacity of
achilled-water cooling coil. It always consists
oftwo globe shutoff valves and connection pipes.
Further equipment depends on the type:
R-CHW3 three-way mixing valve with
anactuator
R-CHW2 throttling valve with an actuator for
digital control system
FK.x
Spare cartride
filters
Replacement filter cartridges in different sizes
based on the unit type. Available in G4, M5 and
F7 filtration class.
H.P
Flexible
connections
Ports can be equipped with flexible connections
upon request.
CF.XXX
Constant air flow
and pressure
Manometers reading fan pressure together
with controls, enables intelligent fan control of
preselected airflow. This accessory assumes
the unit is equipped with digital controls of DC or
RD4 type. Using a second manometer (optional
accessory) in the supply air duct enables the
user to control constant pressure in the supply
duct.
Duct extension
Rectangular duct extension for connection
through the roof. Standard lenght is 1 m.
MFF
Tu b e m a n o m e t e r s
Accessory for filters for simple view of current
pressure drop. The tube manometers are
obligatory for hygienic unit design in accordance
with the VDI 6022.
Base frame
Dismountable base frame with integrated PIR
(30 mm) insulation and service doors. Standard
heigh 400 mm, others on request.
Feets
The Basic-N units can be equipped with an
adjustable feets (alternative to base frame).
Special hoods
Special weatherproof hoods for inlet (e1) and
outlet (i2) ports. The hood for e1 port in combine
with integrated droplet eliminator.
CONTROLS
DUPLEX Basic-N units are delivered with basic control
components or with complete control systems.
There are three types ofcontrol systems available (Basic,
CPand RD4) according tocustomer needs and an
application. The systems also include variety of sensors
(temperature, humidity, air quality, CO2) for effective
operation control.
Type
Use
Basic controls
CP controls
RD4 controls
Standard functions
EC fan speed control (stepless)
automatic by-pass damper position
frost protection of heat exchanger
switching of external electric or built-in water heater
input for external switch
inlet and outlet shut-off damper control
minimum and maximum fan speed preselection
analogue input (010 V) for air quality sensor (CO2, RH)
Controller CPA
fully graphic touchscreen
weekly program
party mode
holiday mode
filter change notice
automatic operation based on constant signal
e.g.constant pressure
Controller CPB
rotable controller
switch for heating allowance
Standard functions
EC fan speed control (based on selected mode)
automatic by-pass damper position (heat and cool
recovery)
evaluates and prevents emergency limits based on
measured temperature
ventilation and temperature weekly program setting
A web server and an Ethernet interface built in as
standard connection for remote internet
communication
inputs for switching using 230 V
(4 inputs 3delayed, 1instantenious) switch e.g.
from bathrooms etc.
optional connection of CO2 or RH sensor
max. 2 sensors with a switch or 010 V output
outputs for electric preheater and heater control
(pulse 10 V) or hot-water control (010 V)
Additional RD4-IO module
optional manometer connection to ensure constant
airflow control (see Constant airflow and pressure
control on previous page)
constant pressure control
cooling control outputs (DX- or chilled-water cooling)
Controller
basic version
(fans, actuators, thermostats,
pressure switches
and others on request)
Controller CPA
with touchscreen
Controller CPB
rotable controller
CP 18 RD
installation in the standard recessed dual box on the wall
CP 19 RD
installation on wall
Web server
(Standard)
Smartphones Application