Вы находитесь на странице: 1из 44

Innovation +

dependability
in air sampling.

The highest standard


in air sampling.
Commitment to quality, dependability, and accuracy established Gilian as the highest standard in air
sampling. Pursuit to uphold the Gilian reputation ensures that innovations found in new Gilian products
deliver desirable features and benefits to Safety Professionals without compromise.
Gilian air sampling products are manufactured in the USA by Sensidyne, a leader in
industrial and environmental health and safety instrumentation.

Table of Contents
Personal Air Sampling Pumps............................................... 4 - 13
Area Air Sampling Pumps.....................................................14 - 15
Calibration Equipment..........................................................18 - 20
Battery Chargers...........................................................................21
Cassettes, Filter Media, & Size Selective Samplers..........22 - 25
Sorbent Tubes & Holders......................................................26 - 27
Impingers, Bubblers & Gas Bags.........................................28 - 29
Air Sampling Guide................................................................30 - 40
Repair & Calibration Services......................................................42

Page 2

Innovation + dependability in air sampling.

Complete Solutions

Well help you assemble your


complete air sampling program.
Gilian personal air sampling systems are worn by workers during their shift to determine exposure to ambient
particulates, gases, or vapors. The Gilian pump draws a precision-controlled volume of air and airborne
contaminants through collection media during the sampling period. After the sampling period, collection media
is sent to a laboratory for analysis resulting in an accurate and representative level of exposure.
The system consists of three components: Collection Media, Holder Assembly and an Air Sampling Pump.
For each, Sensidyne offers a broad array of choices so you are sure to receive exactly the right air sampling
equipment configuration, no matter which NIOSH, OSHA, or other compliance test protocol you follow.
Below is an overview to some of the system choices available and the page numbers where you can find
additional information.
Gilian Pumps
pages 4 - 13
The heart of the air sampling system.

Air Flow Calibrators


pages 18 - 20
To provide optimum air volume accuracy and credibility.

Collection Media & Holders

Battery Chargers
pages 21

Membrane Filters and Cassettes pages 22 - 25


For collecting airborne particulates, aerosols and fumes.
Cyclone Filter & Dust Sampler pages 25
For collecting respirable and inhalable dust particulates.
Media Holders pages 26 - 27
Matching holders for all of our collection media.

To charge, maintain and recharge Gilian batteries.


Air Sampling Guide
pages 30 - 40
Visit this section to look up a contaminant by name and the
recommended sampling configuration.

Sorbent Tubes pages 26 - 27


For single or multiple sampling of vapors and gases.
Impingers and Bubblers pages 28 - 29
For collecting airborne hazards, chemicals and particulates.
Sampling Bags page 29
For collecting high concentrations of hazardous gases and vapors.

Innovation + dependability in air sampling.

Page 3

GilAir Plus

The World's Most Capable Personal Air Sampling Pump

Innovation Delivered

The ultimate air sampling pump delivering


enhanced performance, greater versatility,
and superior design and comfort.

QuadModeSM Air Sampling Technology


Selectable Automatic Fault Recovery
Wide Dynamic Flow Range
Standard Temperature & Pressure Correction
Internal Constant Flow & Pressure Control
Superior Design & Comfort
Real-time Clock with Data-logging

Page 4

Innovation + dependability in air sampling.

The Widest Flow Range of Any Air Sampling Pump


The GilAir Plus features wide dynamic flow and pressure
ranges to address all personal air sampling methods with
flow ranges between 1 and 5,000 cc/min. With patent
pending QuadModeSM air sampling technology, the
GilAirPlus can perform both high-flow constant pressure
and constant flow (450-5,000 cc/min) and low-flow
constant pressure and constant flow (1-499 cc/min) with a
single pump without external adaptors. Its like getting two
pumps in one.
Unmatched Versatility
Samples particulates, vapors, gases, and metal fumes
Works with all common sampling media
 ulti-language capability: English, Spanish, French, Italian,
M
Dutch, Portuguese and German
Outlet port for bag sampling and filling
High Performance
GilAir Plus is a smart pump that provides ambient or
standard temperature and pressure corrected display (STP
model) and data-logging (STP and Datalog model). The
pump has high back pressure capability of up to 40" H2O
in high flow and up to 25" H2O in low flow. An automatic
self check system ensures sample accuracy. In the event
of a fault condition, the pumps selectable automatic fault
recovery feature attempts to restart the pump up to 10
times every 3 minutes to determine if the fault condition
has been cleared.
Ease of Use
An intuitive menu, keypad interface and large, easy-toread back-lit display makes adjusting pump settings quick
and easy. Once the pump is set up, the keypad can be
locked to prevent tampering. Convenient and innovative
SM
SmartCal feature provides automatic pump calibration.

Ergonomic Design
One-third smaller than traditional personal air
sampling pumps and weighing less than 21 oz. (595
g), the GilAirPlus provides superior operator comfort.
An integrated belt clip securely attaches the pump
in a horizontal position, allowing workers a full range
of motion to perform a wide variety of tasks without
interference or discomfort.
Communications
The GilAir Plus dock provides charging and communication
functions for the STP and data-logging models. Once
docked, the PC application allows users to review
datalogs, generate sampling reports, manage sampling
programs, and create pump set-up profiles that expedite
SM
deployment of large pump fleets. The SmartCal
feature uses the dock as a communication link between
appropriate calibration devices and the GilAir Plus.
SmartCalSM automates calibration and records pre and
post sample calibrations in the pumps datalog.

Charging and communications dock shown with


the Gilian Pump Management Software.
Three and five-station docks are available when ordering
multi-pump configurations.

See page 16 for approvals & performance specifications, page 17 for part numbers.

Innovation + dependability in air sampling.

Page 5

Gilian 5000

Industry Leading, Powerful 5 LPM Air Sampling Pump


The Gilian 5000 is the industry leader in back-pressure performance, reliability, and ease-of-use. The Gilian
5000 provides flow rates up to 5,000 cc/min. And thanks to several advanced features, the pump overcomes
the main causes of sampling errors saving you time and money. The air flow display holds calibration for 30
days, even with atmospheric changes. At 70 inches of H2O, the back-pressure capabilities of the Gilian 5000
are the highest in the industry for any personal sampling pump.

Up to 5 LPM
Highest back-pressure capability
Programmable
Live flow display
NiMH battery
EN1232 - Type P compliant

Turns on display

Flow
Sets flow rate (press once), allows calibration (press twice),
program pump (press three times), Set options (press four times)

RUN TIME
Starts, turns off pump - ADJUSTS SETTINGS DOWN

ClearS sample data from memory- ADJUSTS SETTINGS UP

Page 6

Total Volume Sampled


The display auto-cycles through
three screens when the unit is on.

Innovation + dependability in air sampling.

Power equals higher flow rates and higher backpressure capabilities.

The Gilian 5000 provides automatic constant flow from 800


cc/min to 5000 cc/min. When used with a low flow adapter, it
handles low flows from 20 to 800 cc/min under constant pressure
control, such as required for multi-flow sorbent sampling.
At 70 inches of H2O, the Gilian 5000 offers significantly higher
back-pressure capabilities than competitive pumps thanks to
an advanced pneumatic design and powerful battery pack.
As a result, dense particulate buildup on the filter, common in
dusty environments, is far less likely to trigger premature pump
shutdown and an incomplete sample.

Programmable automatic restart when faults occur.

The Gilian 5000 has an intuitive automatic restart feature that


will attempt to save a sample should a fault occur. If the filter
becomes clogged or tubing pinches not allowing air to pass, the
pump will shut down and attempt to restart every 3 minutes for
up to 30 minutes. This option is selectable.

Four-button design is easier to understand and operate.


The Gilian 5000 is easy to understand and configure, four keys
control everything. There are no codes to enter or difficult key
sequences to remember. Operation is simple, intuitive, and less
prone to error. To secure your settings from tampering, the 5000
has a lockable keypad after setup and calibration.

Fast-charge NiMH battery ends "memory" problems.

With the 5000 there is less risk of lost samples due to battery
failure. It incorporates a nickel-metal hydride (NiMH) battery
which, unlike a NiCd battery, doesnt suffer from "memory"
problems. So there is no hidden loss of battery capacity, no
shorter-than-expected run time, and no need for special battery
maintenance.
When the display indicates a "full" battery, thats exactly what
the pump delivers. Plus, the indicator more accurately displays
remaining life throughout the sampling period. You receive
faster charging too. The NiMH battery fully charges in just five
hours. And you wont be hampered with special storage or
disposal requirements, since the NiMH battery is friendly to the
environment.

Easy to calibrate and set-up.

Air flow settings and calibration of the flow rate display are done
through the keypad, requiring only an air flow calibrator. This
means you can set up your pump and begin sampling quickly.
The pump performs an automatic self calibration of internal
temperature and pressure measurement when initially placed in
the run mode and whenever the ambient temperature changes
by more than 3 C during sampling.

Live flow display confirms proper pump operation.

Monitoring the pump for proper operation is easy. A large digital


display continuously cycles to show flow rate, sample run time
and total volume sampled. You receive immediate, real-time
feedback, including live flow, not just the flow setting, which
quickly alerts you to any sudden changes in flow rate.

The toughest, most reliable air sampling pump is also


programmable.
The powerful Gilian 5000 personal air sampling pump is
programmable for automatic start, pause, and stop, with a
pre-set flow rate.

The program mode is easily accessible through the keypad.


The format allows users to enter desired flow rate, a delayed
start time, and up to four run times with pauses (hold times)
in between. This allows, for example, an eight-hour sample
that pauses for the lunch hour and coffee breaks. In the same
program intermittent sampling is possible, starting the pump
to sample a fraction of each hour in the day and spreading
an area sample over four days. This is done by choosing a
run time of five minutes, a delay of 55 minutes and setting the
number of repeated cycles at 96 (i.e., 4 days x 24 hours).

Pump wearers can stop the pump, such as for a break, and the
display remains active. After 75 minutes, the pump automatically
turns off the display if theres no activity but retains all sample
data.

See page 16 for approvals & performance specifications, page 17 for part numbers.

Innovation + dependability in air sampling.

Page 7

GilAir-3 and GilAir-5

Proven, Robust 3 and 5 LPM Air Sampling Pumps


Worldwide, GilAir-3 & GilAir-5 have one of the largest user bases of any air sampling pump thanks to industryleading quality, performance, and dependability. These 3 and 5 liter per minute air sampling pumps have
automatic constant flow compensation, assuring sampling is maintained within 5% of the initial set point. The
easy to use interface of GilAir-3 and GilAir-5 ensuring that performance and reliability are within reach.

Page 8

Innovation + dependability in air sampling.

The most recognized air sampling pump on the market.


GilAir-3 and GilAir-5 deliver dependability and performance on every sample.
Automatic constant flow the most important feature of any sampling pump is
standard on all GilAir-3 and GilAir-5 pumps. It assures flow is maintained within 5%
of the initial set point, even with varying back-pressures from flow restrictions or
buildup of material on the filter. GilAir-3 and GilAir-5 pumps are suitable not only
for conventional pull-through sampling media but also for bag sampling and other
pressure applications.

NiMH batteries are now standard on the GilAir-3 & GilAir-5.

The GilAir-3 and GilAir-5 are equipped with nickel-metal hydride (NiMH) batteries
that virtually eliminate memory effects and lazy battery issues. NiMH batteries are
environmentally friendly, recyclable, and do not pose a risk to the environment when
being disposed. New NiMH battery packs are backwards compatible with GilAir-3
and GilAir-5 pumps that currently use NiCd batteries and are user replaceable by
removing only two screws from the rear of the pump.

GilAir-3 and GilAir-5 pumps feature:


Basic, Clock, & Programmable Models

The GilAir-3 and 5 are available in 3 models; Basic, Clock and


Programmable. The Basic model is straight-forward and easy
to use. Clock models provide an elapsed-time clock display.
Programmable models enable a timer which can start or stop the
pump at preset time intervals or program a delayed start.

External Filter Housing

Clear filter housing allows an immediate visual inspection of the


internal filters condition. This feature protects the pump from dirt
and debris and is externally mounted on the pump, allowing for
quick inspection. Filter replacement requires the removal of just
four screws. A built-in moisture trap helps prevent moisture from
entering and damaging the pump chamber, such as moisture
carryover from impingers.

Flow Fault & Test Indicators

The fault light indicator activates when the pump flow control
is outside 5% of the required flow rate, such as from low
battery, blocked tubing or filter. If fault conditions persist for
30-60 seconds, the pump automatically shuts down and freezes
the timer. Models with a timer display preserve run time on
the display, ensuring a valid sampling result. When the fault
condition is cleared before shutdown, the pump will resume
normal sampling and the fault light turns off. The GilAir-3 & 5
also have a Battery Test indicator light that illuminates when the
battery is fully charged.

Optional Low Flow Modules

Constant Flow module allows sampling from 20-500 cc/min.


Constant Pressure (Multi-flow) Module allows sampling from
1-750 cc/min. These modules can be quickly added to pumps
to adapt them to the lower flow rates required for sorbent tube
sampling. The multi-flow module maintains constant pressure
and allows sampling with multiple sorbent tubes, each with an
independently set flow rate.

See page 16 for approvals & performance specifications, page 17 for part numbers.

Innovation + dependability in air sampling.

Page 9

Gilian BDX-II

Low Cost, 3 Liter Per Minute Abatement Pump


The Gilian BDX-II is an economical air sampling pump designed specifically for asbestos and lead abatement
applications. It is a compact and rugged air sampling pump optimized for sample methods between 500 cc/
min and 3000 cc/min. The BDX-II is powered by a rechargeable NiMH battery that provides up to 10 hours of
operation on a single charge.

Page 10

Innovation + dependability in air sampling.

500-3000 cc/min
Anti-tamper control covers
Sealed internal components
Rechargeable NiMH battery pack
Easy calibration
UL approved for operation in
hazardous areas

Rugged and dependable construction of the BDX-II will withstand


the toughest industrial environments. Without sacrificing
accuracy and reliability, the BDX-II provides an economical
alternative to higher-priced constant flow air sampling pumps.

The BDX-II has a filter that protects the internal pneumatics from
dirt and debris. This filter is externally mounted, enabling users
to quickly and easily inspect filter condition and when necessary
replace the filter.

The built-in rotameter monitors flow rates over the entire flow
range of 0.5 - 3.0 LPM and an electronic flow control adjustment
enables parts to last longer so maintenance is minimized. The
rechargeable NiMH battery provides approximately 10 hours of
reliable operation on a single charge and easily detaches from
the pump body for recharging and/or quick field change in nonhazardous locations. Sealed flow adjustment and on/off switch
protects the BDX-II from moisture, dust and fibers.

BDX-II air sampling pumps accurately monitor for asbestos


using the NIOSH Method 7400 or the OSHA reference sampling
method. The pumps also monitor for lead using NIOSH Methods
7082, 7105 or 7300.
Compact, lightweight and rugged; the BDX-II takes the
complexity out of abatement sampling.

Description

120V

230V

801863-171

801863-171

801863-171-1201

801863-171-2301

298-0017-01

402119

BDX-II 5-Unit Charger

850069

850070

Oil Aerosol Sampling Kit

7013268

7013268

Five Pump Carrying Case (Also fits GilAir-3 & GilAir-5)

800511

800511

375-0003-01

375-0003-01

BDX II Pump, No Charger


BDX II Pump Kit (with Charger, Tool Kit, Tubing, Clip, & Manual)
Single Unit Charger (120V Replaces 402118)

Single Pump Carrier, Soft Side (Also fits GilAir-3, GilAir-5, Gillian 3500 & 5000)
Filter Cassette Holder Kit (required when sampling with cassette)
Filter Housing, Front
Filter, Replacement

800143

800143

201044-10

201044-10

201050

201050

201050-100

201050-100

Rotameter, scaled face plate and internal tubing, 4 LPM

800592

800592

Rotameter, scaled face plate, 4 LPM

801009

801009

Tubing, 1/4" ID x 1/16" W (3 ft)

200484

200484

Filter, Replacement package of 100, (Also fits GilAir-3 & GilAir-5)

Clip Assembly, Replacement for Filter Cassette Kit 800143


Replacement battery pack

800142

800142

783-0008-04

783-0008-04

See page 16 for approvals & performance specifications, page 17 for part numbers.

Innovation + dependability in air sampling.

Page 11

Gilian LFS-113

Compact, Pocket-sized, Low Flow Air Sampling Pump


The LFS-113 is a compact low flow air sampling pump. Designed for flow rates between 1 cc/min and 350 cc/
min, the LFS-113 is perfect for very low flow applications sampling with sorbent tubes. The compact size and
light weight of this pump allow it to easily fit inside a shirt pocket.

Page 12

Innovation + dependability in air sampling.

The LFS-113 features:


Dual Mode Automatic Constant Flow or
Constant Pressure Control
Multi-flow Capacity
Compact Size & Lightweight
Flow Fault Indicator Light
Clock Model with Elapsed Time Display
Battery Check LED
The Gilian LFS-113 low flow sampler is the most powerful and
reliable pocket sized personal air sampler available today. Its
size and robust design makes it the perfect pump for dedicated
low flow sampling applications.
The LFS113 offers two user selectable sampling modes. The
constant flow control mode holds the flow within 5% of the
set flow while the constant pressure control mode [multi-flow]
allows multiple samples to be taken simultaneously through the
use of a multi-flow manifold (see page 27).
The LFS-113 was previously offered in a US and Global version.
Sensidyne recently updated the LFS-113 to provide a single
model version with ATEX, CSA, C-US, and UL approvals. The
LFS-113 is offered in basic and clock models both which feature
a memory-free NiMH battery for fast charges and consistent
performance.

The Compact LFS-113 fits easily in the palm of your hand.

No other pocket-sized pump matches the wide flow range and


high back-pressure capability of the LFS-113.

LFS-113 Starter Kit Shown

See page 16 for approvals & performance specifications, page 17 for part numbers.

Innovation + dependability in air sampling.

Page 13

Gilian AirCon-2

Portable High Volume Area Sampler


Powerful and Portable 2-30 LPM constant flow area air sampler
The AirCon-2 sampler is a high volume unit with an extended flow
range, designed for collecting particulate in a given plant area. It is ideal
for asbestos background and clearance sampling following NIOSH,
OSHA or EPA methodology and for ambient dust monitoring. The
AirCon-2 System is programmable and operates off either AC or battery
power. Back-pressure load can be checked through the LCD display at
any time by simply pressing a button on the front control panel. The
AirCon-2 comes with an adjustable tripod mast and connecting hose
to hold the filter cassette at the proper height and isolate the filter from
the vibration of the unit. Cassette and filter media must be ordered
separately.

Programmable AirCon-2 Sampler


The touchpad and LCD display on the front of the AirCon-2 allow
the user to program as many as three custom timing routines for
unattended sampling. The program feature can be used to control
starts and stops to the sampling run, delays, holds, and number of
cycles. Programming features also include an instant fault function
that terminates the sampling run and locks in the time when the unit
is operated out of its performance envelope. A flashing word FAULT
appears on the display to alert the operator.

Page 14

Innovation + dependability in air sampling.

Programmable AirCon-2 Sampler


AC or Battery Powered

The AirCon-2 offers two power options.


It can operate off a 12Vdc battery
pack, for completely portable sampling
or directly off the charger module
connected to AC, without the use of a
battery. The AirCon-2 does not include
a battery pack and power module,
which must be ordered separately.

12v Battery Packs

4-hour packs can be stacked on top of


each other to obtain up to an 8-hour
sampling period. A power module
charger is required to charge the
battery pack.

55
48
41

Power Module Charger

28

Provides rapid recharging of battery


packs, whether the packs are
independent or connected to the
sampler. That is, it recharges batteries
while s imultaneously powering the
sampler from an AC source. Batteries
are fully charged in 14 hours (running)
or 8 hours (non running).

21
14
7
0

AirCon-2 Samplers offer constant flow c apability, over their


entire 2 to 30 LPM flow range, at back-pressures up to 7 psi
(48 kPa). Flow is controlled within 5% of the set point.

AirCon-2 Sampler

Power Accessories

Programmable Model with Battery Power

Four-Hour Battery Pack

Power Mod. Charger (120V & 230V)

Part Number

801012 -100 (*)

801001(**)

No AC Cord Supplied: 801000-1


With USA AC Cord: 801000-2
With Euro AC Cord: 801000-3

Electrical Input

3.4A @ 12Vdc

95-240 Vdc
@50-60 Hz

Electrical Output

12 Vdc, 13 AH

3.6A @ 14Vdc
(51 watts)

Weight

9.5 lbs. (4.3 kg)

11.5 lbs. (5.2kg)

2 lbs. (0.9 kg)

Overall Dimensions

5.25Wx7.5Dx13.0"H
(13.3Wx19Dx33cm H)

5.25Wx7.5Dx5.5"H
(13.3Wx19Dx14cm H)

5.25Wx7.5Dx3.5"H
(13.3Wx19Dx8.9cm H)

Operating Temperature

-4 to 113F (-20 to 45C)

kPa

35

-40 to 113F (-40 to 45C)

Recommended Filter Media


Airborne Substance

Filter Description

Preload Cassette Part No.

Cassette

Filter Part No. (Replaceable)

Asbestos (OSHA, NIOSH) PCM

25 mm, 0.8 micron, MCEF

GCS 25080

25 mm

GF25080

Asbestos (EPA, AHERA) TEM

25 mm, 0.45 micron, MCEF

GCS 25455-50

25 mm

GF25450

Dust

37 mm, 5 micron, PVC


Previously weighed (0.1 mg)

GCU 37500 PVC


GCU 37500 PVC PW

37 mm
37 mm

GF37500PVC

* Battery-powered Sampler does not include a battery pack or required power module, which must be ordered separately.
** Internal battery replacement requires two batteries, part no. 700285.

Innovation + dependability in air sampling.

Page 15

Gilian Personal Pump Specifications


GilAir Plus

Gilian 5000

GilAir-5

GilAir-3

LFS-113

BDX-II

Total Flow Range

1-5,000 cc/min

20-5,000 cc/min

1 - 5,000 cc/min

1 - 3,000 cc/min

1 - 350 cc/min

500 3,000 cc/min

High Flow Range,


Constant Flow

450-5,000 cc/min
0.45-5LPM

800-5000 cc/min
0.8-5LPM

850-5,000 cc/min
0.85-5.0 LPM

850-3,000 cc/min
0.85-3.0 LPM

1-350 cc/min
0.001-0.35 LPM

500 3,000 cc/min


0.5-3.0 LPM

High Flow Range,


Constant Pressure

450-5,000 cc/min to

--

--

--

--

--

Low Flow Range,


Constant Flow

20-449 cc/min
No module needed

NA

20-500 cc/min

20-500 cc/min

20-200 cc/min

NA

Low Flow Range,


Constant Pressure

1-449 cc/min, @
25 2.5 H2O
(6.2 0.6 kPa)

20-800 cc/min, @
15 1.5 H2O*
(3.7 0.4 kPa)

1-750 cc/min, @
15 1.5 H2O*
(3.7 0.4 kPa)

1-750 cc/min, @
15 1.5 H2O*
(3.7 0.4 kPa)

1-350 cc/min, @
15 1.5 H2O
(3.7 0.4 kPa)

NA

QuadModeSM Capable

Yes

No

No

No

No

No

30 H2O (7.5 kPa)

SmartCal Capable

Yes

Max. Pressure Capability:

Fault

8 hr.
Run

Fault

8 hr.
Run

Fault

8-hr
Run

Fault

8 hr.
Run

@ 0.35 LPM, Inches H2O



(kPa)

25
(6.2)

25
(6.2)

@ 0.75 LPM, Inches H2O


(kPa)

40
(10.0)

40
(10.0)

@ 1 LPM, Inches H2O


(kPa)

40
(10.0)

35
(8.7)

70
(17.5)

70
(17.5)

37
(9.2)

29
(7.2)

@ 2 LPM, Inches H2O


(kPa)

40
(10.0)

30
(7.5)

60
(15.0)

60
(15.0)

37
(9.2)

@ 2.5 LPM, Inches H2O


(kPa)

37
(9.2)

30
(7.5)

50
(12.5)

50
(12.5)

@ 3 LPM, Inches H2O


(kPa)

35
(8.7)

30
(7.5)

50
(12.5)

@ 3.5 LPM, Inches H2O


(kPa)

32
(7.9)

25
(6.2)

@ 4 LPM, Inches H2O


(kPa)

30
(7.5)

@ 5 LPM, Inches H2O


(kPa)

15
(3.7)

SM

Data Shown In Display

Overall Dimensions:
inches
centimeters

No

No

No

No
Fault

No
8 hr.
Run

Fault

8 hr.
Run

25
(6.2)

30
(7.5)

25
(6.2)

26
(6.5)

20
(5.0)

15
(3.7)

32
(8.0)

23
(5.7)

20
(5.0)

15
(3.7)

20
(5.0)

50
(12.5)

32
(8.0)

23
(5.7)

10
(2.5)

8
(2.0)

30
(7.5)

30
(7.5)

20
(5.0)

18
(4.5)

20
(5.0)

30
(7.5)

30
(7.5)

20
(5.0)

18
(4.5)

12
(3.0)

24
(6.0)

20
(5.0)

10
(2.5)

8
(2.0)

Flow Rate, Sample


Time, Battery Level,
Run Time, Predicted
Run Time, Sampling
Mode, Time and
Date, and Sample
Volume in Actual
Conditions.

Live Flow Rate,


Total Sample Time,
Total Volume
Sampled,
Low Battery

Elapsed Time
(clock & timer
models),
Low Battery,
Flow Fault

Elapsed Time
(clock & timer
models),
Low Battery,
Flow Fault

Elapsed Time

NA

4.3W x 2.4H x 2.4D


10.9W x 6.1H x 6.1D

3.2W x 4.9H x 2.0D


8.2W x 12.4H x 5.1D

3.6W x 4.1H x 2.0D


9.1W x 10.4Hx 5.1D

3.6W x 3.5H x 2.0D


9.1W x 8.9H x 5.1D

2.5W x 4.63H x 1.38D


6.4W x11.8H x 3.5D

3.6W x3.5H x 2.0D


9.1W x8.9H x 5.1D

Total Pump Weight

20.5 oz. (0.58 kg)

20.5 oz. (0.58 kg)

22.5 oz. (0.64 kg)

21.0 oz. (0.6 kg)

12 oz. (0.34 kg)

21 oz. (0.6 kg)

Rechargeable Battery

7.2V, NiMH

7.2V, NiMH

6.0V, NiMH

4.8V, NiMH

4.8V, NiMH

4.8V, NiMH

Operating Temperature

32F to113F
0C to 45C

32F to113F
0C to 45C

32F to113F
0C to 45C

32F to113F
0C to 45C

32F to 113F
0C to 45C

32F to 113F
0C to 45C

Certifications***

FM, CE/ATEX, IECEx

FM, CE/ATEX

UL, CE/ATEX

UL, CE/ATEX

UL, CSA,CE/ATEX

UL

Charging Time

< 3.5 hours

< 4 hours

14-16 hours

14-16 hours

14-16 hours

14-16 hours

Battery Life **

300-500 charge cycles, OR 2.5 years with <20 hours weekly use, 1.5-2.5 years (20-39 hours weekly use),
1.0-1.5 years (40-60 hours weekly use)


* Requires installation of low flow module.
Typical back-pressure limit before fault with fully charged battery pack.
** Battery Life estimates based on proper battery maintenance.
Maximum back-pressure for 8-hour run without fault.
*** Consult individual specification sheets as approvals can vary based on model

Page 16

Innovation + dependability in air sampling.

Gilian Personal Sampling Pumps, Kits, and Accessory Part Numbers


GilAir Plus Part Numbers
Starter Kit

Three-Unit Kit

Five-Unit Kit

Basic Model

Datalogging
Model

STP Model

Basic Model

Datalogging
Model

STP Model

Basic Model

Datalogging
Model

STP Model

US Plug

910-0901-US-R

910-0902-US-R

910-0903-US-R

910-0907-US-R

910-0908-US-R

910-0909-US-R

910-0904-US-R

910-0905-US-R

910-0906-US-R

Euro Plug

910-0901-EU-R

910-0902-EU-R

910-0903-EU-R

910-0907-EU-R

910-0908-EU-R

910-0909-EU-R

910-0904-EU-R

910-0905-EU-R

910-0906-EU-R

UK Plug

910-0901-UK-R

910-0902-UK-R

910-0903-UK-R

910-0907-UK-R

910-0908-UK-R

910-0909-UK-R

910-0904-UK-R

910-0905-UK-R

910-0906-UK-R

Gilian Legacy Products Part Numbers


Gilian 5000
Starter Kit, Pump w/ no Clock
- w/ 120V charger
- w/ 230V charger
- ATEX, w/ 230V charger
Starter Kit, Pump w/ Clock
- w/ 120V charger
- w/ 230V charger
- ATEX, w/ 230V charger
Starter Kit, Programmable Pump
- w/ 120V charger
- w/ 230V charger
- ATEX w/ 230V charger
Five-Pack Kit, Pump w/ no Clock
- w/ 120V Universal charger
- w/ 230V Universal charger
- ATEX pump, w/230V five-unit charger
Five-Pack Kit, Pump w/ Clock
- w/ 120V Universal charger
- w/ 230V Universal charger
- ATEX pump, w/230V five-unit charger
Five-Pack Kit, Programmable Pump
- w/ 120V Universal charger
- w/ 230V Universal charger
- ATEX pump, w/230V five-unit charger

NA
NA
NA
NA
NA
NA
910-0802-01
NA
910-0802-02
NA
NA
NA
NA
NA
NA
910-0801-01
NA
910-0801-02

GilAir-3

GilAir-5

Model GilAir-3R
800485-171-1201
800485-171-2301
910-0201-02
Model GilAir-3RC
800508-171-1201
800508-171-2301
910-0204-02
Model GilAir-3RP
800510-171-1201
800510-171-2301
910-0207-02
Model GilAir-3R
800485-171-1205
800485-171-2305
910-0202-02
Model GilAir-3RC
800508-171-1205
800508-171-2305
910-0205-02
Model GilAir-3RP
800510-171-1205
800510-171-2305
910-0208-02

LFS-113

Model GilAir-5R
800883-171-1201
800883-171-2301
910-0101-02
Model GilAir-5RC
800885-171-1201
800885-171-2301
910-0104-02
Model GilAir-5RP
800884-171-1201
800884-171-2301
910-0107-02
Model GilAir-5R
800883-171-1205
800883-171-2305
910-0102-02
Model GilAir-5RC
800885-171-1205
800885-171-2305
910-0105-02
Model GilAir-5RP
800884-171-1205
800884-171-2305
910-0108-02

BDX-II

Model LFS-113DS
910-0301-01
NA
910-0301-02
Model LFS-113DCS
910-0303-01
NA
910-0303-02

Model BDX II
801863-171-1201
801863-171-2301
NA
NA
NA
NA

NA
NA
NA
Model LFS-113DS
910-0302-01
NA
910-0302-02
Model LFS-113DCS
910-0304-01
NA
910-0304-02

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

NA
NA
NA

Accessories
GilAir Plus
Dual Variable Manifold
Sorbent Tube Holder Kit
6x70mm
7 - 10x110mm
Deluxe Variable Manifold Kit (all sizes)
Filter Cassette Holder Kit
Single Sorbent Tube Holder Kit
(no manifold; 6x70mm)
Dual Variable Manifold Sorbent
Tube Holder Kit

6x70mm
7 - 10x110mm
Deluxe Variable Manifold Kit (all sizes)
Filter Cassette Holder Kit
Flow Adapter
- Constant Low Flow Adapter
- Constant Pressure Multi-flow Adapter
Battery Pack
- Standard - NiMH
- AA Alkaline
- DC Power Pack

Gilian 5000

GilAir-3

GilAir-5

LFS-113

BDX-II

800148
801407
800232
800143

800148
801407
800232
800143

800148
801407
800232
800143

800148
801407
800232
800143

800148
801407
800232
800143

NA
NA
NA
800143

800149

800149

800149

800149

800149

NA

800148
801407
800232
800143

800148
801407
800232
800143

800148
801407
800232
800143

800148
801407
800232
800143

800148
801407
800232
800143

NA
NA
NA
800143

NA
NA

NA
801961

800518
800519

800518
800519

NA
NA

NA
NA

783-0012-01-R
783-0013-01-R
783-0014-01-R

783-0007-01
NA
NA

783-0008-03
NA
NA

783-0009-01
NA
NA

783-0003-01
NA
NA

783-0008-04
NA
NA

See page 21 for Gilian chargers.

Innovation + dependability in air sampling.

Page 17

Gilian Gilibrator-2
Primary standard accuracy and performance validation for sampling pump air flows from 1 cc/min
to 30 LPM
Sensidynes Gilibrator-2 System provides users with a convenient and highly automated
way to check almost any commercially available air sampling pump for proper air flow
function before deployment. The system consists of an electronic Gilibrator-2 Base
which is used with any of three sizes of flow cells. These interchangeable components
are also available as part of kits which can also include a complete calibration
diagnostic panel. All cells use a twist-on bayonet design for quick and easy mounting to
the base. All are certified for accuracy and traceable to NIST. Sensidyne recommends
factory calibration of your Gilibrator System at least once a year.

Calibration Cells

Three flow cells are available, for air flow ranges of 1 to 250 cc/min (low flow cell), 20cc/
min to 6 LPM (standard flow cell) and 2 to 30 LPM (high flow cell). These interchangeable
cells generate perfect bubble films at the touch of a button. Infrared sensors read the
bubble flow rate, which is then calculated and displayed.

Gilibrator-2 Base

Easy to operate, microprocessor-controlled unit features simple on/off and reset


touchpad with large LCD screen that displays flow rate, the calculated average of
multiple flow samples in a series and the sample number. Light in weight, it operates
with either AC power or rechargeable batteries (8hour life) for easy portability in either
the lab or the field.

Gilibrator-2 Diagnostic Kit

Offers the industrial hygienist a complete, portable calibration laboratory.


Consists of Gilibrator-2 Base with three flow cells in a cushioned carrying case,
with a full diagnostic panel built into the top lid of the case. The panel uses a
selectable rotameter design for 2 to 5,000 cc/min flow capability and will run
any of several diagnostic tests:
"Load" simulation Offers two load simulations for high and low flows
to imitate sample line back-pressures.
Back-pressure reading A built-in Magnehelic gauge allows visual
monitoring of in-line back-pressures up to 40" H2O (10 kPa).
Leak checking Built-in Magnehelic gauge allows visual leak testing
and monitoring capabilities.
Pump flow adjustment Rotameters allow instant visual indication of
approximate flow rates, assisting in properly adjusting air flows.

Optional PC Interface Kit & Printer

Gilibrator-2 shown with optional


PC Interface Kit

Page 18

A PC Interface Kit is available for real-time data download and manipulation.


The kit includes a cable for connecting a computer to the RS-232 port of the
Gilibrator-2 Base, as well as software that allows the user to log pump and
calibrator serial numbers, data, operator name, flow rates, averaging data,
number of samples, sample sequence, and standard deviation data. An optional
printer is available for hard copy printouts of c alibration data.

Innovation + dependability in air sampling.

Gilibrator-2 Part Numbers & Descriptions


Item
Low Flow Cell Kit (1 to 250 cc)
Standard Flow Cell Kit (20 cc to 6 LPM)
Standard Flow Cell Diagnostic Kit
High-Flow Cell Kit (2 to 30 LPM)
Deluxe Cell Kit (All Three Cell Sizes)

Deluxe Cell Diagnostic Kit


Calibrator Control Base
Control Base Charger

Low Flow Sensor & Cell Assembly


(1 to 250cc)
Standard Flow Sensor & Cell Assembly
(20cc to 6 LPM)
High Flow Sensor & Cell Assembly
(2 to 30 LPM)
Replacement Battery Pack
Replacement Battery Pack
PC Interface Kit
Printer Module, 110v
Printer Module, 230V
Cable For Printer
Printer Paper

Bubble Solution (8 oz.)


Bubble Dispenser

Part No.

Model

800272

(120V)

800272-2

(230V)

Control base, low flow cell, DC charger/AC power supply, tubing and soap
solution with dispenser in hard shell carry case.

800271
800271-2
800844-2
800844-2-230
800270
800270-2
800275
800275-2
801804

(120V)
(230V)
(120V)
(230V)
(120V)
(230V)
(120V, w/ printer)
(230V, w/ printer)
(120V, no printer)

Control base, standard flow cell, DC charger/AC power supply, tubing and soap
solution with dispenser in hard shell carry case.
Same items as standard flow cell Kit, but carry case also includes built-in
diagnostic panel with rotameters and pressure gauge.
Control base, high flow cell, DC charger/AC power supply, tubing and soap
solution with dispenser in hard shell carry case.
Control base, three interchangeable cells for low, standard and high flow rates, DC charger/AC power supply, tubing and soap solution with dispenser, in hard shell carry case.
Thermal printer not included but available as option.

801804-1

(230V, no printer)

800844-4
800844-4-230
850190-1
401984
7017010
400674
400794-1
800267-1

(120V, w/ printer)
(230V w/printer)
(120V)
(230V)
(120V)
(230V)

Description

Same items as Deluxe Cell Kit, but carry case also includes built-in diagnostic
panel with rotameters and pressure gauge.
Includes Battery Pack. Charger sold separately.
For Gilibrator 2 Base (part numbers 850190 and 850190-1)
For Gilibrator 2 Base (part numbers 850190 and 850190-1)
For Gilibrator Base (obsolete) (part number 800268)
For Gilibrator Base (obsolete) (part number 800268)
Sensor and cell assembly only. Includes calibration certificate.

800266-1

Sensor and cell assembly only. Includes calibration certificate.

800265-1

Sensor and cell assembly only. Includes calibration certificate.

700560
400692
811-0501-01
800274
800274-230
800311
400681
402103
402127
800450
400667

For Gilibrator-2 Control Base only.


For Gilibrator Control Base only.
Includes special RS-232 connecting cable with USB adapter and software
Includes printer paper, connecting cable and AC adapter.
Includes printer paper, connecting cable and AC adapter.
Includes connecting cable.
For Gilibrator Printer Module, part no. 400793 (five pack)
For Gilibrator 2 Printer Module, 110v, part no. 801806 (one pack)
For Gilibrator 2 Printer Module, 230V, part no. 700721 (one pack)
For both Gilibrator and Gilibrator 2.
For both Gilibrator and Gilibrator 2.

Gilibrator-2 Specifications

Low Flow Cell


Dimensions: 2W x 4H x 2.1"D (51W x 102H x
53mmD) Weight: 0.4 lbs. (.18 kg)
Standard Flow Cell
Dimensions: 2.5W x 6H x 2.6"D (64W x 152H x
66mmD) Weight: 0.82 lbs. (0.37 kg)
High Flow Cell
Dimensions: 3.5W x 8.1H x 3.7"D (89W x 206H x
94mmD) Weight: 2.26 lbs. (1.02 kg)
Flow Range, Accuracy
Low Flow Cell, 1 - 250 cc/min, 1% of reading
accuracy;
Standard Flow Cell, 20 cc/min to 6 LPM, 1% of
reading accuracy;
High Flow Cell, 2-30 LPM, 1% of reading
accuracy.

Temperature Limits:
Operating Temperature: 5 to 35C (41
to 95F); Storage Temperature: 0 to 50C
(32 to 122F)
Electrical:
DC Power Source: Internal Battery Pack;
AC Power Source: Continuous operation
through adapter/charger; Battery Charge
Time:14 Hrs.; Expected Battery Life: over
300 charge/recharge cycles; Transmission
Link: RS-232; Interface Connectors:
Charger Jack (2.1mm barrel jack), Printer
Jack (DB-25), SensorJack - Cell (DB-9)

Innovation + dependability in air sampling.

Deluxe Diagnostic Kit

Page 19

Gilian Challenger

Precise air flow calibration from 1-30 LPM


Wide temperature range of -30 to +55 C
Displays both actual and standard flow rates
Simple operation with no moving parts
Truly portable, battery powered calibrator
NIST Traceable

The Challenger is a portable and easy to use air flow calibrator for
verifying and calibrating air sampling pumps. The Challenger is
accurate within 0.75% of reading and provides a LCD indication of
Volumetric and Standard flow rate, barometric pressure, and ambient
temperature.
The heart of the Challenger is the Venturi. It is made from aluminum and has no sharp
edges or moving parts. The instrument, depending on the configuration, is capable of
covering the flow rate range of 1 to 30 LPM. The Challenger offers a 90% recovery of
pressure drop which is key to performing a reliable calibration. Because flow through
the instrument is uninterrupted, our graphic software provides a continuous output
display of all functions. This continuous output makes it very simple to configure the
Challenger. Each unit is furnished with a NIST Traceable Certificate and, after adding
the included batteries (4 AA cells), the Challenger is immediately ready to meet your
calibration needs.

Item

Part No.

Model

Description

Gilian Challenger

811-9911-03

Deluxe Kit

Includes Challenger Air Flow Calibrator, 2 Venturi (1 high flow, 1 low flow), carrying bag,
electronic manual and software, batteries, and NIST calibration certificate.

Page 20

Innovation + dependability in air sampling.

Gilian Chargers
Charging solutions that meet your requirements.
Multi-Station Chargers and Communication Docks

The introduction of GilAir Plus brings a new style of charger to the Gilian family available in three- and five-unit models. GilAir Plus uses
a charging dock available in two versions, Basic and Communication-enabled. The Communication-enabled version is for use with the
Datalogging and STP versions of GilAir Plus and allows data communication and use of the SmartCal feature. The Basic charging dock
provides charging for any GilAir Plus model.
Universal five-Station Chargers offer battery charging for up to five GilAir-3, Gilair-5, and BDX-II battery packs. This charger features
Normal/Trickle functions for full or trickle charging to preserve battery performance and prevent overcharging. A dedicated five-station
LFS-113 is also available, this charger provides similar functions to the Universal five-station charger.

Single Station Chargers

Single Station Chargers are also available to match individual pump models.

Pump Compatibility

Part No.

Model

Description

811-0911-US-R
811-0911-EU-R
811-0911-UK-R
811-0912-US-R
811-0912-EU-R
811-0912-UK-R

120V Basic
230V Basic Euro
230V Basic UK
120V Communication
230V Communication Euro
230V Communication UK

Provides charging-only functions for GilAir Plus pumps.

811-0902-US-R
811-0902-EU-R
811-0902-UK-R
811-0904-US-R
811-0904-EU-R
811-0904-UK-R

120V Basic
230V Basic Euro
230V Basic UK
120V Communication
230V Communication Euro
230V Communication UK

Provides charging-only functions for GilAir Plus pumps.

Gilian 3500 & Gilian 5000 Five-Pump


Charger

811-0801-01
811-0801-02

120V
230V

Only for use with Gilian 3500 & Gilian 5000

GilAir-3, GilAir-5, and BDX-II Universal


Five-Pump Charger

850069
850070

120V
230V

For use with GilAir-3, GilAir-5 and BDX-II pumps.

LFS-113 Five-Pump Charger

400324
400373

120V
230V

Only for use with LFS-113 pumps

811-0901-US-R
811-0901-EU-R
811-0901-UK-R
811-0903-US-R
811-0903-EU-R
811-0903-UK-R

120V Basic
230V Basic Euro
230V Basic UK
120V Communication
230V Communication Euro
230V Communication UK

Provides charging-only functions for GilAir Plus pumps.

Gilian 3500 & Gilian 5000

811-0802-01
811-0802-02

120V
230V

US plug
European plug

GilAir-3, GilAir-5 & BDX-II

298-0006-01
401097-1

120V
230V

Replaces 401040
European plug

LFS-113

298-0005-02
400198-1

120V
230V

Replaces 400164
European plug

Multi-Station Chargers
GilAir Plus Three-Unit Charger

GilAir Plus Five-Unit Charger

Provides charging and communication functions for


GilAirPlus pumps.

Provides charging and communication functions for


GilAirPlus pumps.

Single-Station Chargers
GilAir Plus

Innovation + dependability in air sampling.

Provides charging and communication functions for


GilAirPlus pumps.

Page 21

Gilian Sampling Media & Accessories


Sensidyne provides sampling media and accessories for a wide
array of airborne material. This sampling media is available either as
individual components or as pre-loaded cassettes, complete with filters
and support pads.
Cassette sizes, types

37 mm Available in both a standard two-piece style and a three-piece style. These


cassettes meet the NIOSH requirements for sampling most dusts, fumes and mists.
Three-piece cassettes allow open face sampling, typically for asbestos and other fibers.
25 mm Available only in three-piece style, this cassette is used only for "Open Face"
sampling and meets specifications for asbestos sampling, as described by NIOSH,
OSHA and EPA. It has a two-inch extension cowl, assuring proper fiber distribution for
microscopic fiber counts. The carbon imbedded body reduces static charge.
Three-piece 37mm cassette

Membrane types

PVC, Teflon, Glass fiber, Silver, Quartz and MCE (Mixed cellulose ester).

Cellulose shrink seals

Available in both 25mm and 37mm sizes, these bands are applied wet around the
cassette and shrink when dry to form a tight seal. The seal provides a positive nontampering indication when the cassette is received by the lab for analysis.

Cassette holder

Consists of tubing with clip, designed to mount the cassette to the workers collar close
to the breathing zone.
While selection of a specific cassette size/type and filter membrane should be
determined by review of the NIOSH sampling guide, the following rules generally apply:



Two-piece 37mm cassette

All dusts, fumes and powders sampling use 37mm filter and cassette.
All asbestos and fibers sampling use 25mm filter and cassette.
Dust sampling use 0.5 micron (pore size) PVC filter membrane.
Most heavy metal (such as lead fume) sampling use 0.8 micron MCE (mixed ester
of cellulose) filter membrane.*

*Note: Metals form airborne vapors when heated, as these vapors cool and condense they become small airborne
particulates, known as fumes.

8.8
6.2

kPa

7.5

Three-piece 25mm cassette,


Classic Style

5.0
3.7
2.5
1.3
0

Page 22

Innovation + dependability in air sampling.

To Pump
Sample Air Flow

Seal Plug Provided on the outlet and inlet (if applicable) of


cassette and replaced after sampling when cassette is sent
to lab.

Filter Membrane Specific filter membrane used varies with


application. (Refer to NIOSH Method Guidelines, found in Air
Sampling Guide tables starting on page 30.)

Cassette Inlet Cap Used in "Closed Face" sampling and


removed on three-piece 37mm cassette in "Open Face"
sampling. Always removed from 25mm cassette for asbestos
sampling and replaced for shipment to lab.

Support Pad Consists of thick layer of mixed cellulose.

Center Spacer Ring Provided with three-piece 37mm


cassette to allow for "Open Face" Sampling, but not provided
with two-piece 37mm cassette. In 25mm asbestos cassette,
always used for Open Face method, this space is provided
as an elongated 2- inch section.

Luer Fitting Inserted in end of hose to mate with 37mm


cassette outlet. 25mm asbestos cassette does not require a
Luer Fitting.

Gridded Filter Base Gridded design of cross-sectional area


helps to more evenly distribute pump vacuum.

Holder Tubing Holder with collar clip is connected by


tubing to Gilian Pump.

Filter Cassette used with a cyclone.

Filter Cassette as worn by a worker

Innovation + dependability in air sampling.

Page 23

Pre-Loaded Cassettes & Cassette Housings


Description

Sensidyne Part Number

Main Application

Pre-Loaded Cassettes
Cassette, 25mm, Classic Style, PCM, 0.8m, MCE Black Gridded, 50/bx
Cassette, 25mm, Classic Style, PCM, 0.8m MCE Green Gridded, 50/bx
Cassette, 25mm, Classic Style, PCM, 0.8m, MCE, No Grid, 50bx
Cassette, 25mm, Classic Style TEM, 0.45m, MCE, 50/bx
Cassette, 25mm Micro Vac, ea
Cassette, 37mm, 3pc, 0.8m MCE 50/bx
Cassette, 37mm 2pc 5.0m PVC, 50/bx
Cassette, 37mm, 3pc, 5.0m PVC, 50/bx

GCU25080BLG
GCU25080GRG
GCS25080
GCS25455-50
GCU25MV
GCU37080
GCU37500PVC-2
GCU37500PVC

Asbestos, OSHA PCM


Asbestos, OSHA PCM
Asbestos, OSHA PCM
Asbestos, EPA-AHERA TEM

GCU37200T
GCU37AE
GCU37AE-2

Lead, Metals, Welding Fume


Total Dust
Total & Respirable Dust & Silica, Hexavalent Chromium
Coal Tar Pitch Volatiles, Benzene Solubles, NIOSH
Coal Tar Pitch Volatiles, OSHA
Coal Tar Pitch Volatiles, OSHA

Pre-Weighed Cassettes
Cassette, 37mm 2pc 0.8m, MCE Matched (50g), 50/bx
Cassette, 37mm 3pc 0.8m, MCE Matched, (50g), 50/bx
Cassette, 37mm, 3pc, 0.8m, MCE, Matched, Unb. 50/bx
Cassette, 37mm 2pc 5.0m, PVC Matched, (50g), 50/bx
Cassette, 37mm 3pc 5.0m, PVC Matched, (50g), 50/bx
Cassette, 37mm 2pc 5.0m, PVC Preweighed, 50/bx
Cassette, 37mm, 3pc, 5.0m, PVC, Preweighed, (100g) 50/bx

GCU37080MW-2
GCU37080MWU
GCU37080MW
GCU37500PVCMW-2
GCU37500PVCMW
GCU37500PVCPW100
GCU37500PVCPW

Lead, Metals, Welding Fume


Lead, Metals, Welding Fume
Lead, Metals, Welding Fume
Total Dust
Total & Respirable Dust & Silica
Total Dust
Total & Respirable Dust & Silica

Mold Sampling Cassettes


Cassette, Air-O-Cell 10/bx
Cassette, Air-O-Cell 50/bx
Cassette, 37mm .45m PC Endotoxin Free, 10/bx
Cassette, Carpet Sampling, 10/bx

GCAOC10
GCAOC50
GCU3745EF
GCCS10

Mold
Mold

Cassette Housings and Shrink Bands


Band, 25mm Shrink, White, 100/pk
Band, 25mm Shrink, White, 1400/pk
Band, 25mm Shrink, Clear 1400/pk
Band, 25mm Shrink, Yellow 1400/pk
Band, 37mm Shrink, White 100/pk
Band, 37mm Shrink, White, 1000/pk
Band, 37mm Shrink, Clear 100/pk
Band, 37mm Shrink, Clear 1000/pk
Band, 37mm Shrink, Yellow 100/pk
Band, 37mm Shrink, Yellow 1000/pk
Band, 37mm Shrink, Red 100/pk
Band, 37mm Shrink, Red 1000/pk
Housing, 25mm, Classic Style, 3pc, Conductive, 50/bx
Housing, 37mm, 3Pc, 50/bx
Housing, 37mm, 2Pc, 50/bx
Housing, 37mm 2pc Opaque, 50/bx
Housing, 37mm 3pc Opaque, 50/bx
Housing, 37mm 2pc Solvent Res, 50/bx
Housing, 37mm 3pc Solvent Res 50/bx
Housing, 37mm, Conductive 3pc, 50/bx

GB25W
GCO25DNL
GB25C
GB25Y
GB37W
GCO37DNL
GB37C
GB37C1000
GB37Y
GB37Y1000
GB37R
GB37R1000
GH25
GCO37050
GCO37050-2
GH37-2
GH37
GH37SR-2
GH37SR
GH37C

Sterile Cassettes
Cassette, 37mm 3pc .45m MCE BL Grid, Sterile, 50/pk
Cassette, 37mm 3pc .45m MCE Gridded Sterile, 50/pk
Cassette, 37mm 3pc 0.8m MCE Sterile, 50/pk
Cassette, 37mm 3pc 0.8m MCE, BL Grid, Sterile, 50/pk
Cassette, 37mm 3pc 0.8m MCE, Gridded, Sterile, 50/pk

GCU3745BLGS
GCU3745CS
GCU37080S
GCU37080BLGS
GCU37080GS

Cassette, 37mm, 3pc, 2.0m,Teflon, 50bx


Cassette, 37mm 3pc w/ Type A/E Glass Fiber, 50/bx
Cassette, 37mm 2pc w/ Type A/E Glass Fiber, 50/bx

MCE = Mixed Cellulose Esters PVC = Polyvinyl Chloride PTFE = Teflon (DuPont Trademark) m or = micron mm = millimeter
PCM = Phase Contrast Microscope (OSHA Asbestos Method) TEM = Transmission Electron Microscope (EPA Asbestos Method)

Page 24

Innovation + dependability in air sampling.

Cyclone Sampler for respirable dust and silica


This Dorr-Oliver unit meets NIOSH
sampling requirements for 10mm nylon
cyclones, as specified by NIOSH for
nuisance dust (#0600) and silica dust
(#7500, 7501, 7601 and 7602).

air
flow

It is designed to separate the


respirable fraction of airborne dust
from the nonrespirable fraction; i.e.
airborne particles with aerodynamic
diameters between 0.2 and 10
microns, capable of producing
pneumonconiosus lung disease with
long-term e
xposure. Designed for
pneumonconiosus-producing dusts,
it can also monitor the respirable
fraction of all types of dusts, from
high toxic to nuisance particulate.

The unit consists of a two-stage cyclone


and a lightweight aluminum frame, which
mounts a standard 3-part 37mm filter
cassette, with membrane filter. When
air enters the cyclone stage at 1.7 LPM,
the larger nonrespirable particles are

centrifugally separated out and drop into


a removable lower grit pot. The smaller,
respirable particles pass on to the cassette
and are captured by the filter membrane.

Cyclone Calibration Jar

When ordering a cyclone sampler, be


sure to also order a Cyclone Calibration
Jar. Since a cyclone has only a single
hose connection, this jar allows proper
placement of the cyclone filter between
the sampling pump and the calibrator
device.
Tubing
Tubing

CC / MIN

POWER

Cyclone Sampler
in Holder Assembly

Gilibrator

Note how closely the separation achieved by the


Cyclone Sampler (red curve) follows the convention for
separation of respirable particles, as specified by
ACGIH (black curve). Few other cyclone separators
show such a close fit of actual to ideal performance.
For example, 100% of 10 micron particles and 50% of
4 micron particles are removed by the cyclone. This
corresponds with 0% of 10 micron particles and 50%
of 4 micron particles that penetrate the lower lung.

SET

ENTER

CAL

CLEAR

RUN/STOP

Gilian Pump
(at 1.7 LPM)
Cyclone Calibration Jar
(1 liter)

Description

Sensidyne Part Number

Filter Membranes and Support Pads (Pads sold separately)


Filter, MCE, 0.8m 25mm, PCM, with Black Grid Line, 100/pk
Filter, MCE, 0.8m 25mm, PCM, with Green Grid Line, 100/pk
Filter, MCE, 0.8m, 25mm, PCM, No Grid, 100/pk
Filter, MCE, 0.45m, 25mm, TEM 100/pk
Filter, MCE 1.2m 25mm, 100/pk
Filter, MCE, 5.0m, 25mm, 100/pk
Filter, MCE, 0.45m, 37mm, 100/pk
Filter, MCE, 0.8m, 37mm, 100/pk
Filter, MCE, 0.45m, 47mm, 100/pk
Filter, MCE, 0.8m, 47mm, 100/pk
Filter, PVC, 5.0m 25mm, 100/pk
Filter, PVC, 5.0m, 37mm, 100/pk
Filter, PVC, 5.0m 47mm, 100/pk
Filter, PTFE with Polypropylene Backing, 0.5m, 37mm, 100/pk
Filter, PTFE, pure, 2.0m, 37mm, 50/pk
Filter, Glass Fiber, Binderless, 1.1m, 37mm, 100/pk
Filter, Glass Fiber, Binderless, 1.1m, 8" x 10", 100/pk
Filter, Support Pads, Cellulosic, 25mm, 40.0m, 100/pk
Filter, Support Pads, Cellulosic, 37mm, 40.0m, 100/pk
Filter Support Pads, Porous Plastic, 25mm, 100/pk
Filter, Support Pads, Porous Plastic, 37mm, 20.0m, 100/pk

GF25080BLG
GF25080GRG
GF25080
GF25450
GF25120
GF25500
GF37450
GF37080
GF47450
GF47080
GF25500PVC
GF37500PVC
GF47500PVC
GF37050T
GF37200PT
GFG85037MM
GFG858x10
GPG25100
GPG37100
GP25
GPP3700

Cyclone
Cyclone, Dorr-Oliver, 10mm, Nylon
Cyclone Calibration Jar (For Cyclone and Inhalable Dust Sampler Head)
Cyclone Grit Pot, Replacement
Cyclone Vortex Finder Accessory, Replacement

800061
7013376
200159
801124

Inhalable Dust Sampler


Inhalable Dust Sampler (100 m Particle Cut at 2 LPM)
Sampler Filter Cassette, Conductive Plastic, 25mm, Reusable, with Transport Clip

811-9909-01
811-9910-01

MCE = Mixed Cellulose Esters PVC = Polyvinyl Chloride PTFE = Teflon (DuPont Trademark) m or = micron mm = millimeter
PCM = Phase Contrast Microscope (OSHA Asbestos Method) TEM = Transmission Electron Microscope (EPA Asbestos Method)

Innovation + dependability in air sampling.

Page 25

Sorbent Tubes for single or multiple


sampling of vapors and gases using
a low flow sampling pump
These high quality sealed glass tubes are 6x70mm in size,
packed with accurately weighed, high purity coconut shell
charcoal. The specific applicable test methods should be
determined from the Air Sampling Guide on pages 30 to 40.
They are designed to absorb vapors and gases passed through
them, when used with low flow air sampling systems and fit a
variety of holders described here. A tube has sorbent material in two
sections: the first for sample collection and the second for sample
break-through control.
The tips of the tubes are snapped off with a tube tip breaker, just prior
to use. Each tube comes with caps to protect the user from the sharp
glass ends and to seal the tubes after sampling is complete, prior to
sending them to the lab. Tubes are packaged 50 to a box.

This unique system consists of a series of components


which can be used to make up any of a wide range of
different sorbent tube holders. That includes holders for
single tube sampling or for multiple tubes manifolded
together, with variable control of flow rate to each individual
tube. These holders accept not only Sensidyne sorbent tubes
but other standard sized industry tubes.

Tight sealing, visible design

The quality construction of these holders features housings of clear plastic, allowing
easy see-through inspection. In addition, each of the fittings at either end of the
holder contains positive sealing O-rings in a double seal arrangement, eliminating
any possible contamination of the sample by assuring absolute airtight integrity.
They allow the sample tube to be flow-calibrated in place and also permit quick, easy
reconfiguring of tube holder arrangements.

Single Tube Holder Kits

Kit comes with single holder, tubing, adapters and collar clip. Available for any of six
different tube sizes. It can be ordered as a standard tube holder kit for constant flow
control applications, or with a needle valve, which can also be used for variable flow
single tube sampling, with a constant pressure (multi-flow) control in place.

Page 26

Innovation + dependability in air sampling.

Sorbent Tube Kit Descriptions

Starter Single Tube Kit

This is the most popular of our universal


tube holder kits, containing everything
needed to put together holders for
standard single tube sampling, variable
flow single tube sampling, or "in series"
multiple tube sampling. Includes
standard and variable flow tubes
in 6x70mm, 7-10x110mm, 7-10x 150mm
and 7-10x175mm tube sizes. Also
includes tubing, adaptor and collar clips.

Dual, Triple and Quad Kits

Allow simultaneous tandem sampling


with multi-flow control systems (i.e.,
constant pressure control). Contains
tubing, adapters and collar clip, as well
as a manifolded variable flow holder
set, for either dual, triple, or quadruple
sorbent tubes. Available in kits for a
single specific tube size or kits for four
different tube sizes.

Deluxe Universal Tube Holder Kit

Offering the ultimate in sampling


flexibility, this kit allows you to "build
your own" arrangement for almost any
combination of single or multiple tube
(1, 2, 3 and 4) manifolded sampling, for
any of six different tube sizes. Includes
all necessary fittings, adaptors, tubing
and collar clips.


Description

Kit Includes

5x150 mm

6x70 mm

7-10x110 mm

7-10x150 mm

7-10x175 mm

7x130 mm

Single-Tube Holder Kit

(No manifold)

800263

800149*

800259

800260

800261

800262

Single-Variable Manifold Kit

Holder/Ends/Tubing

800254

800253*

800255

800256

800257

800258

Kit Description

Tube Holder Sizes Included (in addition to manifolds, ends and tubing)

Part No.

Starter Kit, Single Variable


Manifold

One each of: 6x70mm, 7-10x110mm, 7-10x150mm and 7-10x175mm

800252

Dual-Variable Manifold Kit

Two of 6x70mm*

800148

Dual-Variable Manifold Kit

Two of 7-10x110mm

801407

Dual-Variable Manifold Kit

Two each: 6x70mm, 7-10x110mm, 7-10x150mm and 7-10x175mm

800251

Triple-Variable Manifold Kit

Three of 6x70mm*

800230

Triple-Variable Manifold Kit

Three each: 6x70mm, 7-10x110mm, 7-10x150mm and 7-10x175mm

800250

Quad-Variable Manifold Kit

Four of 6x70mm*

800231

Quad-Variable Manifold Kit

Four each: 6x70mm, 7-10x110mm, 7-10x150mm,and 7-10x175mm

800249

Deluxe Kit

Four of 6x70mm; three each of 7-10x110mm, 7-10x150mm and 7-10x175mm; two each of 5x150mm and
7x130mm (also includes single, double and triple manifolds, which can be combined to form quad manifold)

800232

* For use with standard activated charcoal tube

Innovation + dependability in air sampling.

Page 27

Impinger/Bubblers
For collecting various airborne gases, vapors and particulates using a high flow sampling pump
Gilian Impingers are special glass tubes designed to collect airborne contaminants by bubbling the sampled air at a high flow rate
through a method-specific absorbing liquid inside. The impinger liquid used can be analyzed to determine airborne contaminant
levels. Impingers can be mounted directly to a personal air sampling pump or a special spill-proof version can be attached to the
workers collar with a clip.

Midget Impingers, 25 ml Standard, "Bubbler" and Special

These two-piece glass impingers have a


capacity of 25 ml and a graduated scale
along the side in 5 ml increments. The
tip is precisely spaced in relation to the
bottom of the impinger.

The Standard Midget Impinger has


its two glass pieces joined by a
24/40 ground joint.

The "Bubbler" or Fritted Midget


Impinger is like the standard
impinger, except it has a special
fritted tip to increase the interaction
between the air sample and the
impinger liquid by breaking the air
stream into smaller bubbles and
thereby increasing surface area.

The Special Midget Impinger has a


Teflon sleeve on the glass stopper,
allowing its use for ozone sampling.

Micro Spill-Proof Midget Impinger

This impinger is designed with traps to


keep the liquid from spilling out, should
they be tipped accidentally. It comes
with a collar clip, allowing placement
within the worker s immediate breathing
zone. Very light in weight, the micro spillproof impinger has a capacity of 2 oz (50
ml) and is made of PVC coated glass.

Moisture Traps & Holders

Moisture traps are designed to prevent


moisture carryover from the impinger
that might internally damage the
sampling pump. Single and double
holders are available for midget
impingers and traps. A mounting bracket
is also required when mounting these
holders to Gilian 5000, Gilian 3500,
GilAir-3, GilAir-5, or BDX II pumps.

Bubbling
action of
fritted tip.

Page 28

Innovation + dependability in air sampling.

Size

Description

Part No.

Impingers
Standard Midget

25ml

2-pc., glass, 5ml increments

400165

Fritted Plastic

2oz

Fritted, 2-pc, plastic

800776

Fritted Midget (Bubbler)

25ml

Fritted, 2-pc., glass, 5ml increments

400506

Special Midget,Teflon

25ml

2-pc., glass, Teflon sleeve, Ozone, 5 ml increments

400509

Spill-proof, Micro, 2 oz.

50 ml

PVC-coated glass, fritted, collar clip

800772

Moisture Traps
Standard Moisture Trap

98 ml

Plastic w/ 36"(91 cm) length of 1/4"(6.4 mm) ID tubing

800217

Midget Sorbent Trap

25 ml

Glass w/ screw cap

200241

Aluminum/black, GilAir-3/GilAir-5

200222

Holders
Impinger Holder, single

Impinger Holder, double

Aluminum/black, GilAir-3/GilAir-5

200131

Mounting Bracket for Impinger Holder

Required to mount impinger holder to GilAir-3, GilAir-5 and BDX II pumps

801146

Mounting Bracket for Impinger Holder

Required to mount impinger holder to Gilian 3500 & Gilian 5000 pump

801983

Gas Sampling Bags


For convenient sample collection of specific compounds

Sensidyne carries a full line of Kynar and Teflon Gas Bags, which are convenient
for grab sampling or TWA sampling of ambient chemical hazards for which other,
conventional sampling methods are not available. NIOSH requires the use of the bag
sampling method for certain compounds.
Reusable Gilian Gas Bags feature a quality construction that offers both durability
and flexibility, as well as very long service life. They are both fatigue and temperature
resistant and have a large sample port for easy flushing.

Kynar Gas Sampling Bags

Teflon Gas Sampling Bags

Capacity (liters)

Nominal Capacity (liters)

Part No.

Valve Type

Part No.

0.5

KB-05

0.5

On/Off Valve

TE-22

1.0

KB-1

1.2

On/Off Valve

TE-21

3.0

KB-3

4.7

On/Off Valve

TE-23

5.0

KB-5

5.0

On/Off Valve

TE-24

10.0

KB-10

0.5

Septum Valve

TE-25

25.0

KB-25

1.2

Septum Valve

TE-26

50.0

KB-50

4.7

Septum Valve

TE-27

100.0

KB-100

50.0

Septum Valve

TE-28

200.0

KB-200

to sample point

Gas Tight Seal

CC / MIN
CC
CC // MIN
MIN

Sample Bag
(1.5 to 2.0 L)

POWER
POWER
ENTER
ENTER

SET
SET
CAL
CAL

CLEAR
CLEAR

RUN/STOP
RUN/STOP

Gilian Pump

Vacuum Sampler with


1 gallon bottle.
(Bottle should be clear or see-through)

Innovation + dependability in air sampling.

Page 29

Specifying Your Sample Train


Heres how to use the Equipment Configuration Table below and the Air Sampling Guide on the following pages to select the
components needed for your air sampling system:
Look up the specific airborne material
you are sampling in the Air Sampling
Guide and note the Configuration Code
in the last column.

Config.
Code
A

Compare the Configuration Code


from the last column with the table
below to find the recommended
collection media, media holder and/or
appropriate accessories.

Collector Type

Primary Use

Collection Media

Media Holder

Cassette Membrane
Filter

Metals

37mm MCEF GCU37080

Filter Holder 800143

Cassette Membrane
Filter

Total Dust

Cassette Membrane
Filter with Cyclone

Respirable Dust
/ Silica

Impinger*

Gases. Vapors &


Aerosols

37mm PVC
GCU37500PVC
GCU37500PVCPW
37mm PVC
GCU37500PVC
GCU37500PVCPW
Impinger* 400165 (see
also spill-proof models)

Gases. Vapors &


Aerosols

Bubbler* 400506 (see


also spill-proof models)

Misc. PTFE**

37mm PFTE

Misc. GFF**

37mm GFF (glass fiber)

Misc. Silver

Silver Membrane

E
F
G
H
I
J

Bubbler*
Cassette Membrane
Filter
Cassette Membrane
Filter
Cassette Membrane
Filter
Cassette Membrane
Filter
Cassette Membrane
Filter

Sorbent Tube

Gas Sampling Bag

N
P

Asbestos
Lead
Abatement
Solvents by ACT
(Single)

Select a Gilian air sampling pump


and appropriate air flow calibrator.

Page
No's

Gilian Pump
Models

Gilibrator-2 (standard
flow)
Challenger

22-24

Cyclone 800061

22-25

Single Impinger Holder


400165
GilAir Bracket 801146
Gilian 3500 Bracket 801983
Gilian 5000 Bracket 801983

28-29

Calibrator

Gilibrator-2
(standard flow) Cyclone
Calibration Jar 7013376
GilAir Plus
Gilian 5000
GilAir-3
GilAir-5
Gilibrator-2 (standard
flow)
Challenger

Filter Holder 800143

22-24

ACT (150 mg) 801935

ACT Single 800149

26-27

Gas Sample Bag


(various sizes &
materials)

Not Applicable

29

25mm MCEF (cellulose


ester) GCS25080
37mm MCEF (cellulose
ester) GCU37080
GilAir Plus
Gilian 5000*
(w/Low Flow
Adapter)
GilAir-3/ GilAir-5
(w/ Constant
Flow Module)
LFS-113

Gilibrator-2 (Low flow or


Standard flow)

GilAir Plus
Gilian
3500/5000
(w/Low Flow
Solvents by ACT
Sorbent Tube
ACT (150 mg) 801935
Appropriate Tube Manifold 26-27 Adapter)
(Multi)
GilAir-3/ GilAir-5
(w/ Multi-flow
Module)
LFS-113
Special Configuration using chemically treated filters & combination media. Please call 800-451-9444 / +1 727-530-3602 for further information.
Other special sampling media. Please call 800-451-9444 / +1 727-530-3602 for further information.
Note: Gilian 5000 pumps require Kit No.811-9901-01 for bag sampling and are limited to area sampling only.
* Impingers and bubblers require a liquid medium specific to the test method.
** PFTE Methods 5010, 5021, 5506, & 5515 us PNP GCU37200T Other PTFE methods require filter assembly.
All GFF and Silver Membrane filters require assembly.

DISCLAIMER: This equipment selection guide and its attached tables are provided in good faith as a general air sampling guide. The tables are based on the NIOSH Manual of Analytical Methods, 4th Edition. It is the
responsibility of the user to determine if alternate test methods are available. References to NIOSH, OSHA or EPA do not imply product endorsement by those agencies.

Page 30

Innovation + dependability in air sampling.

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

Acenaphthene
Acenaphthylene
Acetaldehyde
Acetaldehyde
Acetaldehyde
Acetic acid
Acetic anhydride
Acetone
Acetone cyanohydrin

5506/5515
5506/5515
2538
2539
3507
1603
3506
1300
2506

Polynuclear Aromatic Hydrocarbons 2.0


Polynuclear Aromatic Hydrocarbons
Acetaldehyde
Aldehydes, Screening
Acetaldehyde
Acetic Acid
Acetic Anhydride
Ketones I
Acetone Cyanohydrin

2.0
2.0
0.01-0.05
0.01-0.05
0.1-0.5
0.01-0.1
0.2-1.0
0.01-0.2
0.2

200
200
1
5
6
20
25
0.5
0.3

1000
1000
12
5
60
300
100
3
12

Acetonitrile
Acetylene dichloride
Acetylene tetrabromide
Acetylene tetrachloride
Acids, inorganic
Acrolein

1606
1003
2003
1019
7903
2501

Acetonitrile
Hydrocarbons, Halogenated 0.01-0.2
1,1,2,2-Tetrabromoethane
1,1,2,2-Tetrachloroethane
Acids, Inorganic
Acrolein

0.01-0.2
0.01-0.2
0.2-1.0
0.01-0.2
0.2-0.5
0.01-0.1

3
0.2
50
3.0
3.0
1.5

25
5
100
30
100
48

Acrolein
Acrylonitrile
Aldehydes, screening
Aldrin

2539
1604
2539
5502

Aldehydes, Screening
Acrylonitrile
Aldehydes, Screening
Aldrin & Lindane

0.01-0.05
0.01-0.2
0.01-0.05
0.2-1.0

5
3.5
5
18

5
20
5
240

Alkaline dusts
Allyl alcohol
Allyl chloride
Allyl glycidyl ether
Allyl trichloride
Alumina
Aluminum
Aluminum
Amines, aliphatic
Amines, aromatic
Aminobenzene
2-Aminoethanol
2-Aminoethanol
p-Aminophenylarsonic acid
2-Aminotoluene
Ammonia
n- and sec-Amyl acetate
Aniline
Anisidine
Anthracene
p-Arsanilic acid
Arsenic
Arsenic
Arsenic trioxide
Arsine
Asbestos
Asbestos

7401
1402
1000
2545
1003
0500
7300
7013
2010
2002
2002
2007
3509
5022
2002
6015
1450
2002
2514
5506/5515
5022
7900
7300
7901
6001
7400
7402

Alkaline Dusts
Alcohols Iii
Allyl Chloride
Allyl Glycidyl Ether
Hydrocarbons, Halogenated
Particulates N.O.R.
Elements By Icp
Aluminum & Cpds, As Al
Amines, Aliphatic
Amines, Aromatic
Amines, Aromatic
Aminoethanol Compounds I
Aminoethanol Compounds Ii
Arsenic, OrganoAmines, Aromatic
Ammonia By Vis
Esters I
Amines, Aromatic
Anisidine
Polynuclear Aromatic Hydrocarbons 2.0
Arsenic, OrganoArsenic & Compounds, As As
Elements By Icp
Arsenic Trioxide, As As
Arsine
Asbestos Fibers By Pcm
Asbestos Fibers By Tem

1-4
0.01-0.2
0.01-1.0
0.01-0.2
0.01-0.2
1-2
1-4
1-3
0.01-1.0
0.2-1.0
0.2-1.0
0.01-0.2
0.5-1.0
1-3
0.02-1.0
0.1-0.2
0.01-0.2
0.02-0.2
0.5-1.0
2.0
1-3
1-3
1-4
1-3
0.01-0.2
0.5-16
0.5-16

70
1
16
1.5
2
7
5
10
3
30
30
4
5
50
10
0.1
1
5
24
200
50
30
5
30
0.1
400
400

1000
10
100
8
60
133
100
400
30
150
150
24
300
1000
150
90
10
30
320
1000
1000
1000
2000
1000
10
varies
varies

Asbestos
Asbestos
Aspartame
Azelaic acid
Azinphos methyl

9000
9002
5031
5019
5600

Asbestos, Chrysotile Bulk By Xrd


Asbestos (Bulk) By Plm
Aspartame
Azelaic Acid
Organophosphorus Pesticides

NA
NA
1-3
1-3
0.2-1.0

NA
NA
70
200
12

NA
NA
1200
1000
240

B[a]P
Barium
Benz(a)anthracene
Benzene

5506/5515
7056
5506/5515
3700

Polynuclear Aromatic Hydrocarbons


Barium, Soluble Compounds
Polynuclear Aromatic Hydrocarbons
Benzene By Portable Gc

2.0
1-4
2.0
> 0.02

200
50
200
NA

1000
2000
1000
80%
capac

Guide to Abbreviations:



AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

Analytical Technique

Sample Collection Media

HPLC-FL; Ultraviolet; GC-FID


HPLC-FL; Ultraviolet; GC-FID
GC-FID
GC-FID; Mass Spectrometry
HPLC-Ultraviolet
GC-FID
VIS
GC-FID
GC-Nitrogen phosphorus
detector
GC-FID
GC-FID
GC-FID
GC-FID
Ion Chromatography
GC-Nitrogen phosphorus
detector
GC-FID; Mass Spectrometry
GC-FID
GC-FID; Mass Spectrometry
GC-Electrolytic conductivity
detector
Titration
GC-FID
GC-FID
GC-FID
GC-FID
Grav
ICP-AES
Flame AAS
GC-FID
GC-FID
GC-FID
GC-FID
Ion Chromatography
Ion Chromatography-HYAAS
GC-FID
VIS-Auto
GC-FID
GC-FID
HPLC-Ultraviolet
HPLC-FL; Ultraviolet; GC-FID
Ion Chromatography-HYAAS
Flame AAS
ICP-AES
GFAAS
GFAAS
Phase contrast microscopy
Transmission electron
microscopy
X-Ray Diffraction
Polarized light microscopy
HPLC-Ultraviolet
GC-FID
GC-Flame photometric
detector
HPLC-FL; Ultraviolet; GC-FID
Flame AAS
HPLC-FL; Ultraviolet; GC-FID
GC

PTFE & XAD-2


PTFE & XAD-2
XAD-2; 2-(Hydroxymethyl) piperidine
XAD-2; 2-(Hydroxymethyl) piperidine
Bubbler
Coconut Shell Charcoal Tube
Bubbler
Coconut Shell Charcoal Tube
Poropak QS

P
P
P
P
E
K/M
E
K/M
P

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Silica Gel
Petroleum Charcoal Tube
Silica Gel (washed)
XAD-2; 2-(Hydroxymethyl) piperidine

K/M
K/M
P
P
P
P

XAD-2; 2-(Hydroxymethyl) piperidine


Coconut Shell Charcoal Tube
XAD-2
Glass Fiber Filter & Bubbler

P
K/M
P
N

PTFE
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Tenax
Coconut Shell Charcoal Tube
Polyvinyl Chloride Filter, tared
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Silica Gel
Silica Gel
Silica Gel
Silica Gel
Impinger
PTFE
Silica Gel
Silica Gel + H2SO4
Coconut Shell Charcoal Tube
Silica Gel
XAD-2
PTFE & XAD-2
PTFE
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Coconut Shell Charcoal Tube
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter

F
K/M
K/M
P
K/M
B
A
A
P
P
P
P
D
F
P
P
K/M
P
P
P
F
A
A
A
K/M
I
I

bulk
bulk
PTFE
Polyvinyl Chloride Filter
OVS-2

I
I
F
B
P

PTFE & XAD-2


Mixed Cellulose Ester Filter
PTFE & XAD-2
air bag

P
A
P
L

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

Page 31

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

Benzene
Benzene
Benzidine Dyes
Benzidine
Benzo(a)pyrene
Benzo(b)fluoranthene
Benzo(e)pyrene
Benzo(k)fluoranthene
Benzo(ghi)perylene
Benzoyl peroxide
Benzyl chloride
Beryllium
Beryllium & compounds
Biphenyl
Boron carbide
Boron oxide
Bromine
Bromoform
Bromotrifluoromethane
Bromoxynil
Bromoxynil octanoate
1,3-Butadiene
2-Butanone
2-Butoxyethanol
n-, sec-, & t-Butyl acetate
tert-Butyl alcohol
n- & sec-Butyl alcohol
n-Butylamine
Butyl cellosolve
Butyl glycidyl ether
n-Butyl mercaptan

1501
1500
5013
5509
5506/5515
5506/5515
5506/5515
5506;
5506/5515
5009
1003
7300
7102
2530
7506
0500
6011
1003
1017
5010
5010
1024
2500
1403
1450
1400
1401
2012
1403
1616
2542

Hydrocarbons, Aromatic
Hydrocarbons, Bp 36-126C
Dyes
Benzidine And 3,3'-Dichlorobenzidine
Polynuclear Aromatic Hydrocarbons 2.0
Polynuclear Aromatic Hydrocarbons 2.0
Polynuclear Aromatic Hydrocarbons 2.0
Polynuclear Aromatic Hydrocarbons 2.0
Polynuclear Aromatic Hydrocarbons 2.0
Benzoyl Peroxide
Hydrocarbons, Halogenated
Elements By Icp
Beryllium And Cpds, As Be
Diphenyl
Boron Carbide
Particulates N.O.R.
Chlorine And Bromine
Hydrocarbons, Halogenated
Trifluorobromomethane
Bromoxynil And B'octanoate
Bromoxynil And B'octanoate
1,3-Butadiene
Methyl Ethyl Ketone
Alcohols Iv
Esters I
Alcohols I
Alcohols Ii
N-Butylamine
Alcohols Iv
Butyl Glycidyl Ether
Mercaptans

0.01-0.2
0.01-0.2
1-3
0.2
2.0
2.0
2.0
2.0
2.0
1-3
0.01-0.2
1-4
1-4
0.01-0.5
1.7 or 2.2
1.5-2.0
0.3-1.0
0.01-0.2
0.01-0.05
1-3
1-3
0.01-0.5
0.01-0.2
0.01-0.05
0.01-0.2
0.01-0.2
0.01-0.2
0.01-1.0
0.01-0.05
0.01-0.2
0.1-0.2

5
2
150
20
200
200
200
200
200
40
6
1250
25
15
100
25
8
4
0.3
2
90
5
1
2
1
1
2
2
1
15
10

30
30
500
100
1000
1000
1000
1000
1000
400
50
2000
1000
30
1000
133
360
70
1.0
400
400
25
12
10
10
10
10
100
10
30
150

p-tert-Butyltoluene
Butyraldehyde
Cadmium
Cadmium & compounds
Calcium
Calcium & compounds
Camphor
Carbaryl (Sevin)
Carbon black
Carbon dioxide

1501
2539
7300
7048
7300
7020
1301
5006
5000
6603

Hydrocarbons, Aromatic
Aldehydes, Screening
Elements By Icp
Cadmium And Cpds, As Cd
Elements By Icp
Calcium And Cpds As Ca
Ketones Ii
Carbaryl
Carbon Black
Carbon Dioxide

0.01-0.2
0.05
1-4
1-3
1-4
1-3
0.01-0.2
1-3
1-2
0.02-0.1

1
5
13
25
5
20
1
20
30
NA

Carbon disulfide

1600

Carbon Disulfide

0.01-0.2

29
5
2000
1500
200
400
25
400
570
80%
capac
25

Carbon tetrachloride
Chlordane

1003
5510

Hydrocarbons, Halogenated
Chlordane

0.01-0.2
0.5-1.0

3
10

150
200

Chlorinated camphene
Chlorinated diphenyl oxide

5039
5025

Chlorinated Camphene
Chlorinated Diphenyl Oxide

0.2-1
0.5-1.5

2
8

30
200

Chlorinated terphenyl
Chlorine
Chloroacetaldehyde
Chloroacetic acid
Chlorobenzene
Chlorobromomethane
Chlorodifluoromethane
Chlorodiphenyl

5014
6011
2015
2008
1003
1003
1018
5503

Chlorinated Terphenyl
Chlorine And Bromine
Chloroacetaldehyde
Chloroacetic Acid
Hydrocarbons, Halogenated
Hydrocarbons, Halogenated
Dichlorodifluoromethane
Polychlorobiphenyls

1-3
0.3-1.0
0.05-0.2
0.05-0.2
0.01-0.2
0.01-0.2
0.01-0.05
0.05-0.2

100
2
3
1
1.5
0.5
1
1

1500
90
16
100
40
8
4
50

GC-Electron capture detector


GC-Electrolytic conductivity
detector
GC-Electron capture detector
Ion Chromatography
GC-Electron capture detector
Ion Chromatography
GC-FID
GC-FID
GC-FID
GC-Electron capture detector

2513

Ethylene Chlorohydrin

0.01-0.2

35

GC-FID

2-Chloroethanol

Guide to Abbreviations:



Page 32

AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

Analytical Technique

Sample Collection Media

GC-FID
GC-FID
HPLC-Ultraviolet
HPLC-Ultraviolet
HPLC-FL; Ultraviolet; GC-FID
HPLC-FL; Ultraviolet; GC-FID
HPLC-FL; Ultraviolet; GC-FID
HPLC-FL; Ultraviolet; GC-FID
HPLC-FL; Ultraviolet; GC-FID
HPLC-Ultraviolet
GC-FID
ICP-AES
HGAAS
GC-FID
X-Ray Diffraction
Grav
Ion Chromatography
GC-FID
GC-FID
HPLC-Ultraviolet
HPLC-Ultraviolet
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-Flame photometric
detector
GC-FID
GC-FID; Mass Spectrometry
ICP-AES
Flame AAS
ICP-AES
Flame AAS
GC-FID
VIS
Grav
GC-Thermal conductivity
detector
GC-Flame photometric
detector
GC-FID
GC-Electron capture detector

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
PTFE
Glass Fiber Filter
PTFE & XAD-2
PTFE & XAD-2
PTFE & XAD-2
PTFE & XAD-2
PTFE & XAD-2
Mixed Cellulose Ester Filter
Coconut Shell Charcoal Tube
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Tenax GC
Cyclone & Polyvinyl Chloride Filter
Polyvinyl Chloride Filter
Silver membrane filter
Coconut Shell Charcoal Tube
2 Coconut Shell Charcoal Tube
PTFE
PTFE
Coconut Shell Charcoal Tube
Amb; XE-347
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Silica Gel + H2SO4
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Glass Fiber Filter; HgAc

K/M
K/M
P
G
P
P
P
P
P
A
K/M
A
A
P
C
B
H
K/M
P
F
F
K/M
P
K/M
K/M
K/M
K/M
P
K/M
K/M
N

Coconut Shell Charcoal Tube


XAD-2; 2-(Hydroxymethyl) piperidine
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Coconut Shell Charcoal Tube
Glass Fiber Filter
Polyvinyl Chloride Filter
air bag

K/M
P
A
A
A
A
K/M
G
B
L

Coconut Shell Charcoal Tube & drying


tube
Coconut Shell Charcoal Tube
Mixed Cellulose Ester Filter &
Chromosorb 102
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter

Glass Fiber Filter


Silver membrane filter
Silica Gel
Silica Gel
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
2Coconut Shell Charcoal Tube (lg+sm)
Glass Fiber Filter & (42% & 54% CI)
Florisil
Petroleum Charcoal Tube

G
H
P
P
K/M
K/M
P
P

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

K/M
P
A
A

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

Analytical Technique

Sample Collection Media

Chloroform
4-Chloronitrobenzene
p-Chlorophenol
Chloroprene
Chlorpyrifos

1003
2005
2014
1002
5600

Hydrocarbons, Halogenated
Nitrobenzenes
P-Chlorophenol
-Chloroprene
Organophosphorus Pesticides 0.2-1.0

0.01-0.2
0.01-1.0
0.05-0.2
0.01-0.1
12

1
1
1.5
1.5
240

GC-FID
GC-FID
HPLC-Ultraviolet
GC-FID
OVS-2

Coconut Shell Charcoal Tube


Silica Gel
Silica Gel
Coconut Shell Charcoal Tube

K/M
P
P
K/M
P

Chromic acid
Chromic acid
Chromium
Chromium
Chromium, hexavalent
Chromium, hexavalent
Chrysene
Coal tar naphtha
Coal tar pitch volatiles
Cobalt
Cobalt & compounds
Copper
Copper (dust & fume)
Cresol, all isomers
Crotonaldehyde
Crotonaldehyde
Cryofluorane

7600
7604
7024
7300
7600
7604
5506/5515
1550
OSHA 58
7300
7027
7300
7029
2546
2539
3516
1018

1-4
1-4
1-3
1-4
1-4
1-4
2.0
0.01-0.2
1.5-2.0
1-4
1-3
1-4
1-3
0.01-0.1
0.01-0.05
0.1-0.2
0.01-0.05

8
100
10
5
8
100
200
1.3
480
25
30
5
50
1
5
1
1

VIS
Ion Chromatography
Flame AAS
ICP-AES
VIS
Ion Chromatography
HPLC-FL; Ultraviolet; GC-FID
GC-FID
Grav & HPLC-UV
ICP-AES
Flame AAS
ICP-AES
Flame AAS
GC-FID
GC-FID; Mass Spectrometry
Differential Pulse Polargraphy
GC-FID

Polyvinyl Chloride Filter


Polyvinyl Chloride Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Polyvinyl Chloride Filter
Polyvinyl Chloride Filter
PTFE & XAD-2
Coconut Shell Charcoal Tube
Glass Fiber Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
XAD-7
XAD-2; 2-(Hydroxymethyl) piperidine
Bubbler
2 Coconut Shell Charcoal Tube

B
B
A
A
B
B
P
K/M
G
A
A
A
A
P
P
E
P

Cumene
Cyanides
Cyanides
Cyanuric acid
Cyclohexane
Cyclohexanol
Cyclohexanone
Cyclohexene
1,3-Cyclopentadiene
2,4-D
Demeton

1501
7904
6010
5030
1500
1402
1300
1500
2523
5001
5514

Chromium, Hexavalent
Chromium, Hexavalent
Chromium And Cpds, As Cr
Elements By Icp
Chromium, Hexavalent
Chromium, Hexavalent
Polynuclear Aromatic H/C
Naphthas
Coal Tar Pitch Volatiles
Elements By Icp
Cobalt And Cpds, As Co
Elements By Icp
Copper (Dust & Fumes)
Cresols And Phenol
Aldehydes, Screening
Crotonaldehyde
Dichlorodifluoromethane,
1,2-Dichlorotetrafluoroethane, &
Chlorodifluoromethane
Hydrocarbons, Aromatic
Cyanides, Aerosol And Gas
Hydrogen Cyanide
Cyanuric Acid
Hydrocarbons, Bp 36-126C
Alcohols Iii
Ketones I
Hydrocarbons, Bp 36-126C
1,3-Cyclopentadiene
2,4-D And 2,4,5-T
Demeton

50
150
40
8
GCFPD
400
1000
1000
1000
400
1000
1000
20
960
2000
1500
1000
1500
24
5
49
4

0.01-0.2
0.5-1.0
0.05-0.2
1-3
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.05
1-3
0.2-1.0

1
10
0.6
10
2.5
1
1
5
1
15
30

30
180
90
1000
5
10
10
7
5
200
500

Coconut Shell Charcoal Tube


Mixed Cellulose Ester Filter & Bubbler
soda lime
Polyvinyl Chloride Filter
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Chromosorb 104; maleic anh.
Glass Fiber Filter
Mixed Cellulose Ester Filter & XAD-2

K/M
N
P
B
K/M
K/M
K/M
K/M
P
G
P

Diacetone alcohol
o-Dianisidine
Diatomaceous earth
Diazinon

1402
5013
7501
5600

Alcohols Iii
Dyes
Silica, Amorphous
Organophosphorus Pesticides

0.01-0.2
1-3
1-3
0.2-1

1
150
50
12

10
500
400
240

Coconut Shell Charcoal Tube


PTFE
Polyvinyl Chloride Filter; Cyclone
OVS-2

K/M
P
C
P

Diazomethane
Dibenz(a,h) anthracene

2515
5506/5515

Diazomethane
Polynuclear Aromatic Hydrocarbons

0.2
2.0

6
200

30
1000

XAD-2 (coated)

P
P

Diborane

6006

Diborane

0.5-1.0

60

260

GC-FID
Ion Specific Electrode
VIS
HPLC-Ultraviolet
GC-FID
CG-FID
CG-FID
CG-FID
GC-FID
HPLC-Ultraviolet
GC-Flame photometric
detector
GC-FID
HPLC-Ultraviolet
X-Ray Diffraction
GC-Flame photometric
detector
GC-FID
HPLC-FL; Ultraviolet; GC-FID
PTFE & XAD-2
Plasma emission spectrometry

Dibromodifluoromethane
2-Dibutylaminoethanol
Dibutyl phosphate

1012
2007
5017

Difluorodibromomethane
Aminoethanol Compounds
Dibutyl Phosphate

0.01-0.2
0.01-0.2
1-3

2.5
4
50

10
24
250

Dibutyl phthalate

5020

1-3

200

Mixed Cellulose Ester Filter

Dibutyltin bis(isooctyl
mercaptoacetate)
o-Dichlorobenzene
p-Dichlorobenzene
3,3-Dichlorobenzidine
Dichlorodifluoromethane

5504

Dibutyl Phthalate & Di(2-Ethylhexyl)


Phthalate
Organotin Compounds

GC-FID
GC-FID
GC-Flame photometric
detector
GC-FID

PTFE & Coconut Shell Charcoal Tube w/


oxidizer
2 Coconut Shell Charcoal Tube
Silica Gel
PTFE

1-1.5

50

500

HPLC; GFAAS

Glass Fiber Filter + XAD-2

Hydrocarbons, Halogenated
Hydrocarbons, Halogenated
Benzidine And 3,3'-Dichlorobenzidine
Dichlorodifluoromethane,
1,2-Dichlorotetrafluoroethane &
Chlorodifluoromethane
Hydrocarbons, Halogenated

0.01-0.2
0.01-0.2
0.2
0.01-0.05

1
1
20
1

60
10
100
4

GC-FID
GC-FID
HPLC-Ultraviolet
GC-FID

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Glass Fiber Filter
2 Coconut Shell Charcoal Tube (lg + sm)

K/M
K/M
K/M
P

0.01-0.2

0.5

15

GC-FID

Coconut Shell Charcoal Tube

K/M

1,1-Dichloroethane

Guide to Abbreviations:



1003
1003
5509
1018

1003

AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

K/M
P
F

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

Page 33

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

1,2-Dichloroethane
Dichloroethyl ether
1,2-Dichloroethylene
Dichlorofluoromethane
1,1-Dichloro-1- nitroethane
1,2-Dichloropropane

1003
1004
1003
2516
1601
1013

Hydrocarbons, Halogenated
Dichloroethyl Ether
Hydrocarbons, Halogenated
Dichlorofluoromethane
1,1-Dichloro-1-Nitroethane
Propylene Dichloride

0.01-0.2
0.01-1.0
0.01-0.2
0.01-0.05
0.01-1.0
0.01-0.2

0.5
2
0.2
0.25
1.5
0.1

50
15
5
3
15
3.5

1,2-Dichlorotetrafluoroethane

1018

0.01-0.05

Dicrotophos

5600

Dichlorodifluoromethane,
1,2-Dichlorotetrafluoroethane (Lg + &
Chlorodifluoromethane Sm)
Organophosphorus Pesticides 0.2-1

12

240

OVS-2

Diethanolamine
Diethylamine
2-Diethylaminoethanol
Diethylenetriamine

3509
2010
2007
2540

0.5-1.0
0.01-1.0
0.01-0.2
0.01-0.1

5
3
4
1

Ion Chromatography
GC-FID
GC-FID
HPLC-Ultraviolet

Impinger
Silica Gel
Silica Gel
XAD-2 w/10% 1-naphthylisothiocyanate

D
P
P
P

Di-(2-ethylhexyl)

5020

1-3

10

200

GC-FID

Mixed Cellulose Ester Filter

Difluorodibromomethane
Difluorodichloromethane

1012
1018

0.01-0.2
0.01-0.05

2.5
1

10
4

GC-FID
GC-FID

2 Coconut Shell Charcoal Tube


2 Coconut Shell Charcoal Tube

K/M
P

Diisobutyl ketone
Dimethylacetamide

1300
2004

0.01-0.2
0.01-1.0

1
15

10
80

GC-FID
GC-FID

Coconut Shell Charcoal Tube


Silica Gel

K/M
P

Dimethylamine
N,N-Dimethylaniline
Dimethylarsinic acid
Dimethylformamide
1,1-Dimethylhydrazine
N,N-Dimethyl-p-toluidine
Dimethyl sulfate

2010
2002
5022
2004
3515
2002
2524

Aminoethanol Compounds Ii
Amines, Aliphatic
Aminoethanol Compounds I
Ethylenediamine, Diethylenetriamine, &
Triethylenetetramine
Dibutyl Phthalate And Di(2-Ethylhexyl)
Phthalate
Difluorodibromomethane
Dichlorodifluoromethane,
1,2-Dichlorotetrafluoroethane &
Chlorodifluoromethane
Ketones I
Dimethylacetamide And
Dimethylformamide
Amines, Aliphatic
Amines, Aromatic
Arsenic, OrganoDimethylacetamide & Dimethylformamide
1,1-Dimethylhydrazine
Amines, Aromatic
Dimethyl Sulfate

GCFPD
300
30
24
20

0.01-1.0
0.02-1.0
1-3
0.01-1.0
0.2-1.0
0.02-1.0
0.01-0.2

3
3
50
15
2
20
0.25

30
30
1000
80
100
100
12

Silica Gel
Silica Gel
PTFE
Silica Gel
Bubbler (.1 M HCl)
Silica Gel
Poropak P

P
P
F
P
E
P
P

Dioxane
Diphenyl
Disulfoton

1602
2530
5600

Dioxane
Diphenyl
Organophosphorus Pesticides

0.01-0.2
0.01-0.5
0.2-1

0.5
15
12

15
30
240

Coconut Shell Charcoal Tube


Tenax, GC
OVS-2

K/M
P
P

Dyes- benzidine-,
Elements
Endrin

5013
7300
5519

Dyes, Benzidine-, O-Dianisidine O-Tolidine-, 1-3


Elements By Icp
1-4
Endrin
0.5-1.0

150

500

12

400

GC-FID
GC-FID
Ion Chromatography-HYAAS
GC-FID
VIS
GC-FID
GC-Electrolytic conductivity
detector
GC-FID
GC-FID
GC-Flame photometric
detector
HPLC-Ultraviolet
ICP-AES
GC-Electron capture detector

P
A
P

Epichlorohydrin
EPN

1010
5012

Epichlorohydrin
Epn

0.01-0.2
1-2

2
15

30
700

PTFE
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter &
Chromosorb 102
Coconut Shell Charcoal Tube
Glass Fiber Filter

1,2-Epoxypropane
Ethanol
Ethanolamine
Ethion; Ethoprop

1612
1400
2007
5600

Propylene Oxide
Alcohols I
Aminoethanol Compounds I
Organophosphorus Pesticides

0.01-0.2
0.01-0.05
0.01-0.2
0.2-1

0.5
0.1
4
12

5
1
24
240

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Silica Gel
OVS-2

K/M
K/M
P
P

2-Ethoxyethanol
2-Ethoxyethyl acetate
Ethyl acetate
Ethyl acrylate
Ethyl amyl ketone
Ethylbenzene
Ethyl bromide
Ethyl butyl ketone
Ethyl chloride
Ethylene chlorohydrin
Ethylenediamine

1403
1450
1457
1450
1301
1501
1011
1301
2519
2513
2540

Alcohols Iv
Esters I
Ethyl Acetate
Esters I
Ketones Ii
Hydrocarbons, Aromatic
Ethyl Bromide
Ketones Ii
Ethyl Chloride
Ethylene Chlorohydrin
Ethylenediamine, Diethylenetriamine, &
Triethylenetetramine

0.01-0.05
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
0.02-0.05
0.01-0.2
0.01-0.1

1
1
0.1
1
1
1
0.5
1
0.3
2
1

6
10
10
10
25
24
4
25
3
35
20

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
2 Coconut Shell Charcoal Tube (lg)
Petroleum Charcoal Tube
XAD-2 w/10% 1-naphthylisothiocyanate

K/M
K/M
K/M
K/M
K/M
K/M
K/M
K/M
P
P
P

Guide to Abbreviations:



Page 34

varies varies

AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

Analytical Technique

Sample Collection Media

GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-Electrolytic conductivity
detector
GC-FID

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
2 Coconut Shell Charcoal Tube (lg)
Petroleum Charcoal Tube
Petroleum Charcoal Tube

K/M
K/M
K/M
P
P
P

2 Coconut Shell Charcoal Tube

GC-FID
GC-Flame photometric
detector
GC-FID
GC-FID
GC-FID
GC-Flame photometric
detector
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
HPLC-Ultraviolet

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

K/M
G

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

Analytical Technique

Sample Collection Media

Ethylene dibromide
Ethylene dichloride
Ethylene glycol dinitrate
Ethylene oxide
Ethylene oxide

1008
1003
2507
1614
3702

Ethylene Dibromide
Hydrocarbons, Halogenated
Nitroglycerin & Ethylene Glycol Dinitrate
Ethylene Oxide
Ethylene Oxide By Portable Gc

0.02-0.2
0.01-0.2
0.2-1.0
0.05-0.15
> 0.02

0.1
1
3
1
NA

GC-Electron capture detector


GC-FID
GC-Electron capture detector
GC-Electron capture detector
GC-Photoionization detector

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Tenax, GC
Petroleum Charcoal Tube w/ HBr
air bag

K/M
K/M
P
P
P

Ethylene thiourea

5011

Ethylene Thiourea

1-3

200

25
50
100
24
80%
capac
800

VIS

C/A

Ethylenimine
Ethyl ether
Ethyl formate
Ethyl mercaptan

3514
1610
1452
2542

Ethylenimine
Ethyl Ether
Ethyl Formate
Mercaptans

0.2
0.01-0.2
0.01-0.2
0.1-0.2

1
0.25
0.3
10

48
3
10
150

Fenamiphos

5600

Organophosphorus Pesticides

0.2-1

12

240

OVS-2

Fibrous glass
Fluoranthene

7400
5506/5515

Asbestos & Other Fibers By Pcm


Polynuclear Aromatic Hydrocarbons 2.0

0.5-16
200

HPLC-Ultraviolet
GC-FID
GC-FID
GC-Flame photometric
detector
GC-Flame photometric
detector
Phase contrast microscopy
PTFE & XAD-2

Polyvinyl Chloride Filter or Mixed


Cellulose Ester Filter
Bubbler
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Glass Fiber Filter; HgAc

Mixed Cellulose Ester Filter

A
P

Fluorene
Fluorides

5506/5515
7902

Polynuclear Aromatic Hydrocarbons


Fluorides, Aerosol & Gas

2.0
1-2

400 varies
1000 HPLCFL/UV;
GC-FID
200 1000
HPLC-FL; Ultraviolet; GC-FID
12
800
Ion Specific Electrode

PTFE & XAD-2


Mixed Cellulose Ester Filter & pad w/
Na2CO3

P
N

Fluorides (sol)
Fluorides (insol)
Fluorotrichloromethane
Fonofos

7906
7906
1006
5600

Fluorides By Ic
Fluorides By Ic
Fluorotrichloromethane
Organophosphorus Pesticides

1-2
1-2
0.01-0.05
0.2-1.0

120
800
0.3
12

IC
IC
7
240

Formaldehyde
Formaldehyde
Formaldehyde
Formaldehyde

2541
3500
2539
5700

Formaldehyde
Formaldehyde
Aldehydes, Screening
Formaldehyde On Dust

0.01-0.1
0.2-1.0
0.01-0.05
2

1
1
5
240

36
100
5
1050

MCEF & pad w; Na2CO3


MCEF & pad w; Na2CO3
GC-FID
GC-Flame photometric
detector
GC-FID
VIS
GC-FID; Mass Spectrometry
HPLC-Ultraviolet

Formic acid
Furfural
Furfural
Furfuryl alcohol
Glutaraldehyde
Glycerin mist
Glycidol
Heptanal
n-Heptane
Hexachlorobutadiene
Hexachloro-1,3cyclopentadiene
Hexachloroethane
Hexamethylene- diisocyanate

2011
2529
2539
2505
2532
0500
1608
2539
1500
2543
2518

Formic Acid
Furfural
Aldehydes, Screening
Furfuryl Alcohol
Glutaraldehyde
Particulates N.O.R.
Glycidol
Aldehydes, Screening
Hydrocarbons, Bp 36-126C
Hexachlorobutadiene
Hexachloro-1,3- Cyclopentadiene

0.05-0.2
0.01-0.05
0.05
0.01-0.05
0.01-0.08
1-2
0.01-1.0
0.01-0.05
0.01-0.2
0.05-0.2
0.01-0.2

1
1
5
3
4
7
5
5
4
1
0.25

24
12
5
25
39
133
100
5
4
100
90

Ion Chromatography
GC-FID
GC-FID; Mass Spectrometry
GC-FID
HPLC-Ultraviolet
Grav
GC-FID
GC-FID; Mass Spectrometry
GC-FID
GC-Electron capture detector
GC-Electron capture detector

1003
5521

Hydrocarbons, Halogenated
Isocyanates, Monomeric

0.01-0.2
1.0

3
5

70
500

Hexanal
n-Hexane
2-Hexanone
Hydrazine
Hydrogen bromide
Hydrogen chloride
Hydrogen cyanide
Hydrogen cyanide
Hydrogen flouride
Hydrogen flouride

2539
1500
1300
3503
7903
7903
6010
7904
7903
7902

Aldehydes, Screening
Hydrocarbons, Bp 36-126C
Ketones I
Hydrazine
Acids, Inorganic
Acids, Inorganic
Hydrogen Cyanide
Cyanides, Aerosol & Gas
Acids, Inorganic
Fluorides, Aerosol & Gas

0.01-0.05
0.01-0.2
0.01-1.0
0.2-1.0
0.2-0.5
0.2-0.5
0.05-0.2
0.5-1.0
0.2-0.5
1-2

5
4
1
7
3
3
2
7
3
12

5
4
10
100
100
100
90
100
100
800

GC-FID
HPLC-Electrochemical
detector
GC-FID; Mass Spectrometry
GC-FID
GC-FID
VIS
Ion Chromatography
Ion Chromatography
VIS
Ion Specific Electrode
Ion Chromatography
Ion Specific Electrode

Hydrogen flouride

7906

Fluorides By Ic

1-2

800

Ion Chromatography

Hydrogen sulfide
Hydroquinone

6013
5004

Hydrogen Sulfide
Hydroquinone

0.1-1.5
1-4

1.2
30

40
180

Ion Chromatography
HPLC-Ultraviolet

Guide to Abbreviations:



AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

Coconut Shell Charcoal Tube (lg)


OVS-2

E
K/M
K/M
N

P
P
P
P

XAD-2; 2-(Hydroxymethyl) piperidine


PTFE & 2 Impinger
XAD-2; 2-(Hydroxymethyl) piperidine
Inspirable Dust Sampler; Polyvinyl
Chloride Filter
PTFE & Silica Gel (washed)
XAD-2; 2-(Hydroxymethyl) piperidine
XAD-2; 2-(Hydroxymethyl) piperidine
Poropak Q
Silica Gel; DNPH
Polyvinyl Chloride Filter
Coconut Shell Charcoal Tube
XAD-2; 2-(Hydroxymethyl) piperidine
Coconut Shell Charcoal Tube
XAD-2
2 Poropak T

P
N
P
C

Coconut Shell Charcoal Tube


Impinger

K/M
D

XAD-2; 2-(Hydroxymethyl) piperidine


Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Bubbler
Silica Gel
Silica Gel
soda lime
Mixed Cellulose Ester Filter
Silica Gel
Mixed Cellulose Ester Filter & pad w/
Na2CO3
Mixed Cellulose Ester Filter & pad w/
Na2CO3
PTFE & Coconut Shell Charcoal Tube (lg)
Mixed Cellulose Ester Filter

P
K/M
K/M
E
P
P
P
A
P
N

P
P
P
P
P
B
K/M
P
K/M
P
P

N
P
A

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

Page 35

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

Indeno [1,2,3-cd] pyrene


Iodine
Iron
Isoamyl acetate
Isoamyl alcohol
Isobutyl acetate
Isobutyl alcohol
Isobutyraldehyde
Isocyanates

5506/5515
6005
7300
1450
1402
1450
1401
2539
5521

Polynuclear Aromatic Hydrocarbons


Iodine
Elements By Icp
Esters I
Alcohols Iii
Esters I
Alcohols Ii
Aldehydes, Screening
Isocyanates, Monomeric

2.0
0.5-1.0
1-4
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.05
1.0

200
15
5
1
1
1
2
5
5

1000
225
100
10
10
10
10
5
500

Isophorone
Isopropyl acetate
Isopropyl alcohol
Isopropyl ether
Isopropyl glycidyl ether
Isovaleraldehyde
Kepone
Kerosene
Lead
Lead
Lead
Lead sulfide
Lindane

2508
1454
1400
1618
1620
2539
5508
1550
7082
7105
7300
7505
5502

Isophorone
Isopropyl Acetate
Alcohols I
Isopropyl Ether
Isopropyl Glycidyl Ether
Aldehydes, Screening
Kepone
Naphthas
Lead By Faas
Lead By Hgaas
Elements By Icp
Lead Sulfide
Aldrin And Lindane

0.01-1.0
0.02-0.2
0.01-0.2
0.01-0.05
0.01-0.2
0.01-0.05
0.5-1.0
0.01-0.2
1-4
1-4
1-4
1.7 or 2.2
0.2-1.0

2
0.1
0.2
0.1
1
5
50
1.3
200
1
1250
600
18

25
9
3
3
30
5
600
20
1500
1500
2000
1000
240

Lithium
Lithium hydroxide
Magnesium
Malathion

7300
7401
7300
5600

Elements By Icp
Alkaline Dusts
Elements By Icp
Organophosphorus Pesticides

1-4
1-4
1-4
0.2-1

100
70
5
12

2000
1000
67
60

Maleic Anhydride
Manganese
MBK
MDI (4,4'-methylenebisphenyl isocyanate)
Mercury
Mercaptans

3512
7300
1300
5521

Maleic Anhydride
Elements By Icp
Ketones I
Isocyanates, Monomeric

0.2-1.5
1-4
0.01-0.2
1.0

40
5
1
5

500
200
10
500

6009
2542

Mercury
Mercaptans

0.15-0.25
0.1-0.2

2
10

100
150

Mesityl oxide
Metals in air
Methamidophos

1301
7300
5600

Ketones Ii
Elements By Icp
Organophosphorus Pesticides

0.01-0.2
1-4
0.2-1

1
25
varies 2000
12
240

Methanol
2-Methoxyethyl acetate
2-Methoxyethanol
Methyl acetate
Methyl acrylate
Methylal
Methyl-(n-amyl)-ketone
Methylarsonic acid
Methyl cellosolve
Methyl cellosolve acetate
Methyl chloride
Methyl chloroform
Methyl cyanide
Methyl cyclohexane
Methylcyclohexanol
Methylcyclohexanone
Methylene chloride
4,4'-Methylenedianiline
Methyl ethyl ketone
Methyl ethyl ketone peroxide

2000
1451
1403
1458
1459
1611
1301
5022
1403
1451
1001
1003
1606
1500
1404
2521
1005
5029
2500
3508

Methanol
Methyl Cellosolve Acetate
Alcohols Iv
Methyl Acetate
Methyl Acrylate
Methylal
Ketones Ii
Arsenic, OrganoAlcohols Iv
Methyl Cellosolve Acetate
Methyl Chloride
Hydrocarbons, Halogenated
Acetonitrile
Hydrocarbons, Bp 36-126C
Methylcyclohexanol
Methylcyclohexanone
Methylene Chloride
4,4'-Methylenedianiline
Methyl Ethyl Ketone
Methyl Ethyl Ketone Peroxide

0.02-0.2
0.01-0.2
0.01-0.05
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
1-3
0.01-0.05
0.01-0.2
0.01-0.1
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.05
0.01-0.2
1-2
0.01-0.2
0.5-0.2

1
0.2
6
0.2
1
1
1
50
6
0.2
0.4
0.1
3
4
1
1
0.5
10
0.25
52

Guide to Abbreviations:



Page 36

5
20
50
10
5
3
25
1000
50
20
3
8
25
4
15
6
2.5
1000
12
520

AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

Analytical Technique

Sample Collection Media

HPLC-FL; Ultraviolet; GC-FID


Ion Chromatography
ICP-AES
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID; Mass Spectrometry
HPLC-Electrochemical
detector
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID; Mass Spectrometry
GC-Electron capture detector
GC-FID
Flame AAS
HGAAS
ICP-AES
X-Ray Diffraction
GC-Electrolytic conductivity
detector
ICP-AES
Titration
ICP-AES
GC-Flame photometric
detector
HPLC-Ultraviolet
ICP-AES
GC-FID
HPLC-Electrochemical
detector
AAS-cold
GC-Flame photometric
detector
GC-FID
ICP-AES
GC-Flame photometric
detector
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
Ion Chromatography-HYAAS
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
HPLC-Ultraviolet
GC-FID
VIS

PTFE & XAD-2


Coconut Shell Charcoal Tube w/ alkali
Mixed Cellulose Ester Filter
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
XAD-2; 2-(Hydroxymethyl) piperidine
Impinger

P
P
A
K/M
K/M
K/M
K/M
P
D

Petroleum Charcoal Tube


Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
XAD-2; 2-(Hydroxymethyl) piperidine
Mixed Cellulose Ester Filter & Impinger
Coconut Shell Charcoal Tube
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Cyclone & Polyvinyl Chloride Filter
Glass Fiber Filter & Bubbler

P
K/M
K/M
K/M
K/M
P
N
K/M
A/J
A/J
A/J
C
N

Mixed Cellulose Ester Filter


PTFE
Mixed Cellulose Ester Filter
OVS-2

A
F
A
P

Bubbler
Mixed Cellulose Ester Filter
Coconut Shell Charcoal Tube
Impinger

E
A
K/M
D

Hopcalite vap
Glass Fiber Filter; HgAc

P
N

Coconut Shell Charcoal Tube


Mixed Cellulose Ester Filter
OVS-2

K/M
A
P

Silica Gel
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
PTFE
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
2 Coconut Shell Charcoal Tube (lg + sm)
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Poropak Q
2 Coconut Shell Charcoal Tube
Glass Fiber Filter; H2SO4
Molecular Sieve (carbon)
Impinger

P
K/M
K/M
K/M
K/M
K/M
K/M
F
K/M
K/M
P
K/M
K/M
K/M
K/M
P
K/M
N
P
D

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

5-Methyl-3-heptanone
Methyl iodide
Methyl isoamyl acetate
Methyl isobutyl carbinol
Methyl isobutyl ketone
Methyl mercaptan

1301
1014
1450
1402
1300
2542

Ketones Ii
Methyl Iodide
Esters I
Alcohols Iii
Ketones I
Mercaptans

0.01-0.2
0.01-1.0
0.01-0.2
0.01-0.2
0.01-0.2
0.1-0.2

1
15
1
1
1
10

25
50
10
10
10
150

Methyl methacrylate
Methyl parathion

2537
5600

Methyl Methacrylate
Organophosphorus Pesticides

0.01-0.05
0.2-1

1
12

8
240

alpha-Methyl styrene
Methyl tert-butyl ether
Mevinphos

1501
1615
5600

Hydrocarbons, Aromatic
Methyl Tert-Butyl Ether
Organophosphorus Pesticides

0.01-0.2
0.1-0.2
0.2-1.0

1
2
12

30
96
240

Mineral spirits
Molybdenum
Monocrotophos

1550
7300
5600

Naphthas
Elements By Icp
Organophosphorus Pesticides

0.01-0.2
1-4
0.2-1

1.3
5
12

20
67
240

Monomethylaniline
Monomethylhydrazine
Naphtha (coal tar)
Naphthalene
Naphthalene
Naphthylamines
Nickel
Nickel carbonyl
Nicotine

3511
3510
1550
1501
5506
5518
7300
6007
2544

Monomethylaniline
Monomethylhydrazine
Naphthas
Hydrocarbons, Aromatic
Polynuclear Aromatic H/C
Naphthylamines
Elements By Icp
Nickel Carbonyl
Nicotine

0.2-1.0
0.5-1.5
0.01-0.2
0.01-1.0
2.0
0.2-0.8
1-4
0.05-0.2
1.0

11
3
1.3
100
200
30
25
7
60

100
20
20
200
1000
100
1000
80
400

Nitric acid
Nitric oxide

7903
6014

Acids, Inorganic
Nitric Oxide & Nitrogen Dioxide

0.2-0.5
0.025

3
1.5

100
6

p-Nitroaniline
Nitrobenzene
p-Nitrochlorobenzene
Nitroethane
Nitrogen dioxide
Nitroglycerin
Nitromethane

5033
2005
2005
2526
6014
2507
2527

P-Nitroaniline
Nitrobenzenes
Nitrobenzenes
Nitroethane
Nitric Oxide & Nitrogen Dioxide
Nitroglycerin & Ethylene Glycol Dinitrate
Nitromethane

1-3
0.01-1
0.01-1
0.01-0.05
0.025-0.2
0.2-1.0
0.01-0.05

16
10
1
1.5
1.5
3
1.2

350
150
150
3
6
100
3

2-Nitropropane
Nitrosamines
Nitrotoluene
Nitrous oxide

2528
2522
2005
6600

2-Nitropropane
Nitrosamines
Nitrobenzenes
Nitrous Oxide

0.01-0.05
0.2-2.0
0.01-0.2
NA

0.1
15
1
NA

Nuisance dusts
n-Octane
1-Octanethiol

0500
1500
2510

Particulates N.O.R.
Hydrocarbons, Bp 36-126C
1-Octanethiol

1-2
0.01-0.2
0.01-0.2

7
4
1

2
1000
30
80%
capac
133
4
15

Oil mist (mineral)


5026
Organophosphorus Pesticides 5600

Oil Mist, Mineral


Organophosphorus Pesticides

1-3
0.2-1

20
12

500
240

Oxygen
Paraquat
Parathion

6601
5003
5600

Oxygen
Paraquat
Organophosphorus Pesticides

NA
1-4
0.2-1.0

1
40
12

NA
1000
240

Particulates N.O.R.
Pentachlorobenzene
Pentachloroethane
Pentachlorophenol
Pentamidine
n-Pentane

0600
5517
2517
5512
5032
1500

Particulates, N.O.R, Resp.


Polychlorobenzenes
Pentachloroethane
Pentachlorophenol
Pentamidine Isethionate
Hydrocarbons, Bp 36-126C

1.7 or 2.2
0.01-0.2
0.01-0.2
0.5-1.0
1-2
0.01-0.05

20
3
1
48
50
2

400
12
10
480
1500
2

Guide to Abbreviations:



AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

Analytical Technique

Sample Collection Media

GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-Flame photometric
detector
GC-FID
GC-Flame photometric
detector
GC-FID
GC-FID
GC-Flame photometric
detector
GC-FID
ICP-AES
GC-Flame photometric
detector
GC-FID
VIS
GC-FID
GC-FID
HPLC-Ultraviolet; GC-FID
GC-FID
ICP-AES
HGAAS
GC-Nitrogen phosphorus
detector
Ion Chromatography
VIS

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Glass Fiber Filter; HgAc

K/M
K/M
K/M
K/M
K/M
P

XAD-2
OVS-2

P
P

Coconut Shell Charcoal Tube


2 Coconut Shell Charcoal Tube (lg)
OVS-2

K/M
P
P

Coconut Shell Charcoal Tube


Mixed Cellulose Ester Filter
OVS-2

K/M
A
P

Bubbler; H2SO4
Bubbler; HCl
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
PTFE & XAD-2
Glass Fiber Filter & Silica Gel
Mixed Cellulose Ester Filter
Coconut Shell Charcoal Tube (low Ni)
XAD-2

E
E
K/M
K/M
P
P
A
K/M
P

Silica Gel (washed)


Molecular Sieve w/ Triethanolamine &
oxidizer
Mixed Cellulose Ester Filter
Silica Gel
Silica Gel
2XAD-2
Molecular Sieve w/ Triethanolamine
Tenax-GC
Chromosorb 106

P
P

Chromosorb 106
Thermosorb; N
Silica Gel
air bag

P
P
P
L

Polyvinyl Chloride Filter


Coconut Shell Charcoal Tube
Tenax GC

B
K/M
P

Polyvinyl Chloride Filter or MCE


OVS-2

A/B
P

portable
PTFE
OVS-2

P
F
P

Cyclone & Polyvinyl Chloride Filter


PTFE & XAD-2
Poropak R
Mixed Cellulose Ester Filter & Bubbler
Polyvinyl Chloride Filter; opaque
Coconut Shell Charcoal Tube

C
P
P
N
B
K/M

HPLC-Ultraviolet
GC-FID
GC-FID
GC-FID
VIS
GC-Electron capture detector
GC-Flame photometric
detector
GC-FID
GC-TEA
GC-FID
Infrared Spectrophotometry
GRAV
GC-FID
GC-Flame photometric
detector
Infrared Spectrophotometry
GC-Flame photometric
detector
Sensor
HPLC-Ultraviolet
GC-Flame photometric
detector
Grav.
GC-Electron capture detector
GC-Electron capture detector
HPLC-Ultraviolet
HPLC; FL
GC-FID

A
P
P
P
P
P
P

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

Page 37

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

2-Pentanone
Petroleum ether/naphtha
Phenol
Phenyl ether
Phenyl ether-diphenyl mixture
Phenyl glycidyl ether
Phenylhydrazine
Phorate

1300
1550
2546
1617
2013
1619
3518
5600

Ketones I
Naphthas
Cresols And Phenol
Phenyl Ether
Phenyl Ether-Diphenyl Mixture
Phenyl Glycidyl Ether
Phenylhydrazine
Organophosphorus Pesticides

0.01-2.0
0.01-0.2
0.01-0.1
0.01-0.2
0.01-0.2
0.01-1
0.2-1.0
0.2-1

1
1.3
1
1
1
80
25
12

10
20
24
50
40
150
120
240

Phosdrin (mevinphos)

5600

Organophosphorus Pesticides

0.2-1

12

480

Phosphine
Phosphoric acid
Phosphorus
Phosphorus

6002
7903
7300
7905

Phosphine
Acids, Inorganic
Elements By Icp
Phosphorus

0.01-0.2
0.2-0.5
1-4
0.01-0.2

1
3
50
5

16
100
2000
100

Phosphorus trichloride
Platinum
PAH
Polyacrylate
Polychlorobiphenyl (42% &
54% Cl)
Potassium hydroxide
Propionaldehyde
n-Propyl acetate
n-Propyl alcohol
Propylene dichloride

6402
7300
5506
5035
5503

Phosphorus Trichloride
Elements By Icp
Polynuclear Aromatic H/C
Super Absorbent Polymer
Polychlorobiphenyls

0.05-0.2
1-4
2.0
1-2
0.05-0.2

11
13
200
50
1

100
2000
1000
1500
50

7401
2539
1450
1401
1013

Alkaline Dusts
Aldehydes, Screening
Esters I
Alcohols Ii
Propylene Dichloride

1-4
0.01-0.05
0.01-0.2
0.01-0.2
0.01-0.2

70
5
1
1
0.1

1000
5
10
10
3.5

Propylene oxide
Pyrene
Pyrethrum
Pyridine
Ribavirin
Ronnel

1612
5506
5008
1613
5027
5600

Propylene Oxide
Polynuclear Aromatic Hydrocarbons
Pyrethum
Pyridine
Ribavirin
Organophosphorus Pesticides

0.01-0.2
2.0
1-4
0.01-1.0
1-4
0.2-1

0.5
200
20
18
5
12

5
1000
400
150
1000
60

Rotenone
Rubber solvent
Selenium
Silica, amorphous

5007
1550
7300
7501

Rotenone
Naphthas
Elements By Icp
Silica, Amorphous

1-4
0.01-0.2
1-4
1.7 or 2.2

8
1.3
5
50

Silica in coal mine dust


Silica, crystalline

7603
7601

Silica In Coal Mine Dust


Silica, Crystalline

1.7 or 2.2
1.7 or 2.2

Silica, crystalline

7602

Silica, Crystalline (Ir)

Silica, crystalline,

7500

Config.
Code

Analytical Technique

Sample Collection Media

GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
VIS
GC-Flame photometric
detector
GC-Flame photometric
detector
VIS
Ion Chromatography
ICP-AES
GC-Flame photometric
detector
VIS
ICP-AES
HPLC-FL; Ultraviolet
Ion ChromatographyP or AAS
GC-Electron capture detector

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
XAD-7
Coconut Shell Charcoal Tube
Silica Gel
Coconut Shell Charcoal Tube
Bubbler; HCl
OVS-2

K/M
K/M
P
K/M
P
K/M
E
P

OVS-2

Silica Gel; Hg(CN)2


Silica Gel (washed)
Mixed Cellulose Ester Filter
Tenax GC

P
P
A
P

Bubbler; H2O
Mixed Cellulose Ester Filter
PTFE & XAD-2
Polyvinyl Chloride Filter
Glass Fiber Filter & Florisil

E
A
P
B
P

PTFE
XAD-2; 2-(Hydroxymethyl) piperidine
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Petroleum Charcoal Tube

F
P
K/M
K/M
P

Coconut Shell Charcoal Tube


PTFE & XAD-2
Glass Fiber Filter
Coconut Shell Charcoal Tube
Glass Fiber Filter
OVS-2

K/M
P
G
K/M
G
P

400
20
2000
400

titration
GC-FID; Mass Spectrometry
GC-FID
GC-FID
GC-Electrolytic conductivity
detector
GC-FID
HPLC-FL; Ultraviolet; GC-FID
HPLC-Ultraviolet
GC-FID
HPLC-Ultraviolet
GC-Flame photometric
detector
HPLC-Ultraviolet
GC-FID
ICP-AES
X-Ray Diffraction

F
K/M
A
B/C

300
400

1000
800

Infrared Spectrophotometry
VIS

1.7 or 2.2

400

800

Infrared Spectrophotometry

Silica, Crystalline, Resp.

1.7 or 2.2

400

1000

X-Ray Diffraction

Silver
7300
Sodium hexafluoro aluminate 7902
Sodium hexafluoro- aluminate 7906

Elements By Icp
Fluorides, Aerosol & Gas

1-4
1-2

250
12

2000
800

ICP-AES
Ion Specific Electrode

Fluorides By Ic

1-2

120

800

Ion Chromatography

Sodium hydroxide
Stibine
Stoddard solvent
Strychnine
Styrene
Sulfur dioxide

7401
6008
1550
5016
1501
6004

Alkaline Dusts
Stibine
Naphthas
Strychnine
Hydrocarbons, Aromatic
Sulfur Dioxide

1-4
0.01-0.2
0.01-0.2
1-3
0.01-1.0
0.5-1.5

70
4
1.3
70
1
4

1000
50
20
1000
14
200

Titration
VIS
GC-FID
HPLC-Ultraviolet
GC-FID
Ion Chromatography

Sulfur hexafluoride

6602

Sulfur Hexafluoride

0.01-0.05

NA

GC-Electron capture detector

7903

Acids, Inorganic

0.2-0.5

80%
capac
100

PTFE
Coconut Shell Charcoal Tube
Mixed Cellulose Ester Filter
Polyvinyl Chloride Filter (total) or
Polyvinyl Chloride Filter & Cyclone
Cyclone & Polyvinyl Chloride Filter
Cyclone & MCE or Polyvinyl Chloride
Filter
Cyclone, & MCE or Polyvinyl Chloride
Filter
Cyclone & Polyvinyl Chloride Filter
respirable
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter & pad w/
Na2CO3
Mixed Cellulose Ester Filter & pad w/
Na2CO3
PTFE
Silica Gel w/ HgCl2
Coconut Shell Charcoal Tube
Glass Fiber Filter
Coconut Shell Charcoal Tube
Mixed Cellulose Ester Filter & Cellulose
w/ Na2CO3
air bag

Ion Chromatography

Silica Gel (washed)

Sulfuric acid

Guide to Abbreviations:



Page 38

AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

C
C
C
C
A
N
N
F
P
K/M
G
K/M
N
L

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

Sulfuryl fluoride
Sulprofos

6012
5600

Sulfuryl Fluoride
Organophosphorus Pesticides

0.05-0.1
0.2-1

1.3
12

10
240

Super absorbent polymer


2,4,5-T
Tellurium
Terbufos
o-Terphenyl
1,1,2,2-Tetrabromoethane
Tetrabutyltin
1,2,4,5- Tetrachlorobenzene
1,1,2,2-Tetrachloro-2,2difluoroethane
1,1,1,2-Tetrachloro-1,2difluoroethane
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Tetraethyl lead
Tetraethyl pyrophosphate

5035
5001
7300
5600
5021
2003
5504
5517
1016

1-3
1-3
1-4
0.2-1
1-3
0.2-1.0
1-1.5
0.01-0.2
0.01-0.035

50
15
25
12
2
50
50
3
0.5

0.01-0.035

1019
1003
2533
2504

Super Absorbent Polymer


2,4-D And 2,4,5-T
Elements By Icp
Organophosphorus Pesticides
O-Terphenyl
1,1,2,2-Tetrabromoethane
Organotin Compounds
Polychlorobenzenes
1,1,2,2-Tetrachloro-2,2-Difluoroethane &
1,1,2,2-Tetrachloro-1,2-Difluoroethane
1,1,2,2-Tetrachloro-2,2-Difluoroethane &
1,1,2,2-Tetrachloro-1,2-Difluoroethane
1,1,2,2-Tetrachloroethane
Hydrocarbons, Halogenated
Tetraethyl Lead (As Pb)
Tetraethyl Pyrophosphate

Tetrahydrofuran
Tetramethyl lead
Tetramethyl thiourea
Tetranitromethane
Thallium
Thiram
Tin, organic compounds as Sn
Titanium
o-Tolidine
Toluene

1609
2534
3505
3513
7300
5005
5504
7300
5013
4000

Toluene
Toluene
2,4 & 2,6-Toluenediamine
Toluene-2,4-diisocyanate
Toluene-2,4-diisocyanate

Config.
Code

Analytical Technique

Sample Collection Media


Coconut Shell Charcoal Tube (lg)
OVS-2

P
P

1500
200
2000
240
30
100
500
12
2

Ion Chromatography
GC-Flame photometric
detector
Ion ChromatographyP or AAS
HPLC-Ultraviolet
ICP-AES
GC-FID
GC-FID
GC-FID
HPLC; HGAAS
GC-Electron capture detector
GC-FID

Polyvinyl Chloride Filter


Glass Fiber Filter
Mixed Cellulose Ester Filter
OVS-2
PTFE
Silica Gel
Glass Fiber Filter & XAD-2
PTFE & XAD-2
Coconut Shell Charcoal Tube

B
G
A
P
F
P
P
P
K/M

0.5

GC-FID

Coconut Shell Charcoal Tube

K/M

0.01-0.2
0.01-0.2
0.01-1.0
0.01-0.2

3
0.2
30
20

30
40
200
48

PCT
Coconut Shell Charcoal Tube
XAD-2
2 Chromosorb 102

P
K/M
P
P

Tetrahydrofuran
Tetramethyl Lead (As Pb)
Tetramethyl Thiourea
Tetranitromethane
Elements By Icp
Thiram
Organotin Cpds. (As Sn)
Elements By Icp
Dyes
Toluene

0.01-0.2
0.01-0.2
0.2-1.0
0.5-1.0
1-4
1-4
1-1.5
1-4
1-3
NA

Coconut Shell Charcoal Tube


XAD-2
Impinger; H2O
Impinger; EtAc
Mixed Cellulose Ester Filter
PTFE
Glass Fiber Filter & XAD-2
Mixed Cellulose Ester Filter
PTFE

K/M
P
D
D
A
F
P
A
P
P

1500
1501
5516
2535
5521

Hydrocarbons, Bp 36-126C
Hydrocarbons, Aromatic
2,4- & 2,6-Toluenediamine
Toluene-2,4-Diisocyanate
Isocyanates, Monomeric

0.01-0.2
0.01-0.2
1.0
0.2-1.0
1.0

1
15
50
20
25
10
50
5
150
(15
min)
(8 h)
2
1
30
2
5

GC-FID
GC-FID
GC-Photoionization detector
GC-Flame photometric
detector
9
GC-FID
100
GC-Photoionization detector
250
VIS
250
GC-FID
2000
ICP-AES
400
HPLC-Ultraviolet
500
HPLC; HGAAS
100
ICP-AES
500
HPLC-Ultraviolet
GC-FID passive

8
8
500
170
500

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Impinger
Glass Wool (coated)
Impinger

K/M
K/M
D
P
D

Toluene-2,6-diisocyanate

5521

Isocyanates, Monomeric

1.0

500

Impinger

o-Toluidine
Tribromomethane
Tributyl phosphate

2002
1003
5034

Amines, Aromatic
Hydrocarbons, Halogenated
Tributyl Phosphate

0.02-1.0
0.01-0.2
1-3

10
4
2

150
70
100

Silica Gel
Coconut Shell Charcoal Tube
Mixed Cellulose Ester Filter

P
K/M
A

Tributyltin chloride
1,2,4-Trichlorobenzene
1,1,2-Trichloroethane
1,1,1-Trichloroethane
Trichloroethylene
Trichloroethylene

5504
5517
1003
1003
1022
3701

Organotin Compounds
Polychlorobenzenes
Hydrocarbons, Halogenated
Hydrocarbons, Halogenated
Trichloroethylene
Trichloroethylene By Portable Gc

1-1.5
0.01-0.2
0.01-0.2
0.01-0.2
0.01-0.2
> 0.02

50
3
2
0.1
1
NA

Glass Fiber Filter & XAD-2


PTFE & XAD-2
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
air bag

P
P
K/M
K/M
K/M
L

Trichlorofluoromethane
Trichloromethane
1,2,3-Trichloropropane
Trichcylohexyltin hydroxide
1,1,2-Trichloro-1,2,2trifluoroethane
Triethanolamine
Triethylenetetramine

1006
1003
1003
5504
1020

Fluorotrichloromethane
Hydrocarbons, Halogenated
Hydrocarbons, Halogenated
Organotin Compounds
1,1,2-Trichloro-1,2,2- Trifluoroethane

0.01-0.05
0.01-0.2
0.01-0.2
1-1.5
0.01-0.05

0.3
1
0.6
50
0.1

500
12
60
8
30
80%
capac
7
50
60
500
3

GC-FID
GC-FID
HPLC-Ultraviolet
HPLC-Ultraviolet
HPLC-Electrochemical
detector
HPLC-Electrochemical
detector
GC-FID
GC-FID
GC-Flame photometric
detector
HPLC; HGAAS
GC-Electron capture detector
GC-FID
GC-FID
GC-FID
GC
GC-FID
GC-FID
GC-FID
HPLC-HGAAS
GC-FID

Coconut Shell Charcoal Tube


Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Glass Fiber Filter & XAD-2
Coconut Shell Charcoal Tube

K/M
K/M
K/M
P
K/M

3509
2540

0.5-1.0
0.01-0.1

5
1

300
20

Ion Chromatography
HPLC-Ultraviolet

Impinger
D
XAD-2 w/10% 1-naphthylisothiocyanate P

Trifluorobromomethane
Trimellitic anhydride

1017
5036

Aminoethanol Compounds Ii
Ethylenediamine, Diethylenetriamine, &
Triethylenetetramine
Trifluorobromomethane
Trimellitic Anhydride

0.01-0.05
1.5-2

0.1
400

1
1000

GC-FID
GC-FID

2 Coconut Shell Charcoal Tube (lg+sm)


Polyvinyl Chloride Filter

Guide to Abbreviations:



1016

AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

P
B

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

Page 39

Airborne
Material
Sampled

NIOSH
Method
No.

NIOSH Method Name

Sampling Sampling
Flow Rate Volume
(LPM)
Min Max

2,4,7-Trinitrofluoren-9-one
Triorthocresyl phosphate

5018
5037

2,4,7-Trinitro-Fluoren-9-One
Triorthocresyl Phosphate

1-3
1-3

100
2

500
100

Triphenyl phosphate

5038

Triphenyl Phosphate

1-3

10

400

Tungsten, soluble/ insoluble


Turpentine
Valeraldehyde
Valeraldehyde
Vanadium
Vanadium oxides
Vinyl acetate
Vinyl benzene
Vinyl bromide
Vinyl chloride
Vinylidene chloride
Vinyl toluene
VM&P naphtha
Warfarin
Xylene
2,4-Xylidine
Yttrium
Zinc and compounds
Zinc
Zinc oxide
Zirconium

7074
1551
2536
2539
7300
7504
1453
1501
1009
1007
1015
1501
1550
5002
1501
2002
7300
7030
7300
7502
7300

Tungsten (Soluble/Insoluble)
Turpentine
Valeraldehyde
Aldehydes, Screening
Elements By Icp
Vanadium Oxides
Vinyl Acetate
Hydrocarbons, Aromatic
Vinyl Bromide
Vinyl Chloride
Vinylidene Chloride
Hydrocarbons, Aromatic
Naphthas
Warfarin
Hydrocarbons, Aromatic
Amines, Aromatic
Elements By Icp
Zinc And Compounds, As Zn
Elements By Icp
Zinc Oxide
Elements By Icp

1-4
0.01-0.2
0.01-0.04
0.01-0.05
1-4
1.7 or 2.2
0.1-0.2
.01-1
0.01-0.2
0.05
0.01-0.2
0.01-0.2
0.01-0.2
1-4
0.01-0.2
0.02-0.2
1-4
1-3
1-4
1-3
1-4

200
1
0.5
5
5
200
0.75
1
2
0.7
2.5
1
1.3
200
2
3
5
2
5
10
5

1000
10
10
5
2000
1000
24
14
10
5
7
24
20
1000
23
20
1000
400
200
400
200

Guide to Abbreviations:



Page 40

AAS = Atomic absorption spectrophotometry


Grav = Gravimetric (filter weight)
DNPH = Dinitrophenylhydrazine HCI
GFAAS Graphite furnace AAS (heated)
FID Flame ionization detector
HPLC = High performance liquid chromatography
FL Fluorescence detector
HYAAS = Hydride generation AAS
GC Gas chromatography

Config.
Code

Analytical Technique

Sample Collection Media

HPLC-Ultraviolet
GC-Flame photometric
detector
GC-Flame photometric
detector
Flame AAS
GC-FID
GC-FID
GC-FID; Mass Spectrometry
ICP-AES
X-Ray Diffraction
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
GC-FID
HPLC-Ultraviolet
GC-FID
GC-FID
ICP-AES
Flame AAS
ICP-AES
X-Ray Diffraction
ICP-AES

PTFE
Mixed Cellulose Ester Filter

F
A

Mixed Cellulose Ester Filter

Mixed Cellulose Ester Filter


Coconut Shell Charcoal Tube
XAD-2; 2-(Hydroxymethyl) piperidine
XAD-2; 2-(Hydroxymethyl) piperidine
Mixed Cellulose Ester Filter
Cyclone & Polyvinyl Chloride Filter
Molecular Sieve (carbon)
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube (lg)
2 Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
Coconut Shell Charcoal Tube
PTFE
Coconut Shell Charcoal Tube
Silica Gel
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Mixed Cellulose Ester Filter
Polyvinyl Chloride Filter
Mixed Cellulose Ester Filter

A
K/M
P
P
A
C
P
K/M
P
K/M
K/M
K/M
K/M
F
K/M
P
A
A
A
B
A

ICP-AES = Inductively coupled plasma-atomic emission spectroscopy


NA = Not Applicable
OVS-2 = OSHA versatile sampler (quartz filter / XAD-2)
PTFE = Polytetrafluoroethylene (Teflon) filter
VIS = Visible absorption spectrophotometry

Innovation + dependability in air sampling.

Colorimetric Gas Detector Tubes


HazMat emergencies or routine inspection, detector tubes are a quick and low-cost method
of measuring for a wide-range of airborne gases and vapors without waiting for laboratory
analysis. Detector tubes are used with a simple-to-use handheld pump that carefully
draws a precise amount of air through the detector tube. Quickly the contents of the
tube will change color if the target gas or vapor is present.
Low-cost sampling
Quick results
Flow-finish indicator
Highly portable
Shatterproof tubes
No batteries to charge

Low-cost, effective sampling.

Sensidyne detector tubes are inexpensive and do not


require costly laboratory analysis. Our detector tubes
are available for over 300 different gases and
vapors and in many different ranges. Reading
the tube is as simple as taking the sample and
reading the concentration directly off the scale
printed on the tube.
The Sensidyne detector tube pump is
intrinsically safe and can be used anywhere
a hazardous substance may be found. The
pump is made of durable materials rugged
enough for any industrial setting yet the
antibacterial grip makes it safe
for clean rooms, hospitals or
anywhere bacterial transfer
is a concern.

First responders Depend upon Sensidyne HazMat kits.

In addition to testing for a single target substance, Sensidyne offers a HazMat kit that enables first responders and HazMat teams
to rapidly identify and qualify unknown gases and vapors. In less than three minutes one user can identify over 70 hazardous
compounds. On-the-spot testing and results eliminate laboratory turnaround. Since the tubes are pre-calibrated they are ready to
use whenever and wherever a potential hazard may occur.
Sensidyne offers OEM detector tube development for custom and specialty applications.
Visit our website or contact our Customer Support team to request a full catalog
of our detector tubes, pump kits and accessories:
Tel: 800-451-9444 / 727-530-3602 x 782 or Email: info@Sensidyne.com

Innovation + dependability in air sampling.

Page 41

Sensidyne Nephelometer

Real-time Aerosol / Dust Monitor for TSP


Easy-to-Use
Two-button user-interface ensures easy dust level monitoring.

Accurate Dust Concentration


Proprietary algorithm provides accurate total suspended
particulate (TSP) concentration. The sheath air feature prevents
internal contamination and improves accuracy.

Reliable
Temperature compensated, durable housing and minimal
moving parts ensure reliability.

Highly Portable
All-in-one handheld instrument with long-life batteries that fully
charge in less than 3 hours.

Environment Profiling
Easy to use software allows programming unique environmental
profiles and recording sample data.

Common Applications
Industrial/Occupational Hygiene Area Surveys
Particulate Matter Studies
Immediate spot measurement
Aerosol Research Studies

Page 42

The Sensidyne Nephelometer


is an advanced real-time dust
monitor accurately measuring dust
concentrations using proven light
scatter technology. This portable
instrument accurately measures and
records dust from 1-10,000 g/m3 with
resolution to 1 g/m3. Sample modes
are selectable between 60 second
sample, 15 minute STEL, or continuous
sampling.

stream. The instrument multiplies


each measurement by a K-factor and
displays the real-time reading on the
display of the instrument. After each
sample, the K-factor and Environmental
Factor Name and STEL, maximum,
minimum, and average readings
record to the internal data log. When
connected to a computer the instrument
uploads up to 4,000 data-log records in
spreadsheet format.

The Nephelometer has an internal


pump drawing samples into the isokinetic sampling inlet where they meet
sheath air that guides samples past the
particle sensor. The sensor is a photo
detector that measures laser light
scattered by particulates in the sample

In addition to high sensitivity and easeof-use the Sensidyne Nephelometer


offers a low cost of ownership,
automatic power save, long-life, datalogging, facility monitoring features, and
user-replaceable filters.

Innovation + dependability in air sampling.

Expert Knowledge, Expert Service


We know your Gilian products better than anyone...
Factory Service, Repair and
Calibration

Sensidyne's team of well qualified


technicians can quickly diagnose
and repair almost any problem with
your Gilian products. And because we
design and manufacture the products
we are also repair experts.
We repair not only current Sensidyne
equipment, but past models as well.
You get expert knowledge and skills,
from repair and calibration technicians
with many years of experience. Using
factory repair service ensures your
product's approvals remain valid.

Sensidyne repairs each product model


at flat rate prices. The repair service,
regardless of the problem, also
includes a complete reconditioning of
the product, including replacement of
any critical worn parts.
All Sensidyne service work is backed
by a six-month warranty. Quick
turnaround is standard, but for those
who need it even faster, we also offer
emergency rush service.

9000 calibration system requirements.


You always receive fast, accurate
calibration, all at a surprisingly modest
cost.
Contact Sensidyne Service for more
information:
Tel: 800-451-9444 / 727-530-3602 x
781 or
Email: Service@Sensidyne.com

Sensidyne recommends factory


calibration of your Gilibrator System
annually. Our service department
provides this service with N.I.S.T.
traceability, in accordance with ISO

Other Sensidyne Products

The Leader in Industrial Health & Safety Instrumentation


Sensidynes business is segmented
into three product groups:

pumps used to monitor worker exposure


to airborne vapors and particulates.

Gas Detection
Air and Particulate Sampling
Micro Air Pumps

Sensidyne Micro Air Pumps are miniature


diaphragm pressure and vacuum air
pumps supplied to original equipment
manufacturers for use in a wide range
of applications including medical, gas
sampling and analytical instrumentation.

The Gas Detection products include fixed


point gas detectors and gas detector
tubes. Detector Tubes are fast, easy to
use, direct-reading instruments to test
for the presence of airborne gases and
vapors. Sensidyne has detector tubes
for more than 300 gases and vapors.
The system is simple to use, employing
a piston style hand pump and glass
colorimetric tubes.
Gilian, a Sensidyne brand and world
leader in personal air sampling pumps,
consists of a range of high precision

Visit our website or contact our Customer


Support team to gain more information
on any Sensidyne product.
Tel: 800-451-9444 / +1 727-530-3602
Fax: 727-539-0550
Web: www.Sensidyne.com
www.SensidyneGasDetection.com
Email: info@Sensidyne.com

Innovation + dependability in air sampling.

Page 43

Proudly Distributed By:

Sensidyne is a registered ISo 9001:2008 facility.


Headquarters:

Internet:

Sensidyne, lP 1000 112th Circle North Suite 100


St. Petersburg, Florida 33716 united States
Tel: 800.451.9444 / +1 727.530.3602
Fax: +1 727.539.0550
www.Sensidyne.com info@Sensidyne.com

Doc: GC0521
Pub. Date: 06/2012

Europe:

Sensidyne, lP c/o Schauenburg Electronic Technologies GmbH


Weseler Str. 35 45478 Mlheim-ruhr Germany
Tel: +49 208 99 91 - 111

Вам также может понравиться