Blowers
ASGE Technical Conference
June 7, 2011
Induced metal
Induced plastic
Pressure metal
Dilution air water heater
Non-Dilution air water heater
Premix
Internal Fan
Plastic housing
Plastic impellers
Flue gas temperature
throughout housing
typically 120F +/-
Pressure Blowers
Mounting
Flanges
Sleeve Vents
Cooling fan
Room Air
Intake
Combustion
Exhaust
Room Air
Intake
Direct Vent
Exhaust
Exhaust
Typical 120F
2% CO2 +/-
Outside Air
mixing
Water Heater
Typical 400F Flue Gas
8%CO2 +/-
Premix Blowers
Negative
pressure
gas valve
3.3 Motors
Shaded Pole 2-Pole
PSC
2-Pole
Stator
Stator
Rotor
C-Frame Motor
Stator and Bobbin
Assembly
Motor
Thermal Protection
Common Protector types include:
Auto reset overloads automatically reconnect
power to the motor after the coils have cooled to a
safe level.
Manual reset protectors include a reset button to
close the protector contacts when the motor can
be safely re-started.
One shot protectors will not be reset. The motor
winding is permanently opened if the protector
operates.
Impedance protection means the motor is simply to weak
to develop dangerously high temperatures. These
motors do not include an additional protective device.
Types of Bearings
Sleeve Bearing
in a motor end
plate
Ball Bearing
Ball Bearing
in a motor
end plate
Fan Laws
Flow rate varies directly as
the speed ratio
Flow rate varies directly as
the width ratio
Pressure varies as the
square of the speed ratio
Flow rate varies as the cube
of the fan diameter ratio
Horse Power varies as the
cube of the speed ratio.
Horsepower varies
inversely as the square of
the density ratio
Breakdown Point
Torque(ozin)
30.0
25.0
20.0
15.0
10.0
Start Torque
5.0
Idle Speed
0.0
0
500
1000
1500
2000
Speed(RPM)
2500
3000
3500
Operating
range
Efficiency
30%
25%
20%
15%
10%
5%
0%
0
500
1000
1500
2000
Speed(RPM)
2500
3000
3500
3380
Speed RPM
3340
3320
3300
3280
0
20
40
60
20
40
60
80
100
3.5
Static Pressure In. W.C. (@ Std Air)
Blower Wind
Tunnel Curve
3360
3.0
2.5
2.0
1.5
1.0
0.5
0.0
CFM
80
100
3.5
3.0
2.5
2.0
1.5
System curve
1.0
0.5
0.0
0
10
20
30
40
50
CFM
60
70
80
90
Example - 60 to 50hz
Appliance input rate = 400,000Btu/Hr
Blower 100CFM 2.7 Static press
3530RPM 60Hz 2.2% slip
At 50 Hz speed=(120X50/2) X .978 =
2934RPM
New Flow = 100 X 2940/3530 = 83.3 CFM
New SP = 2.7 X(2940/3530)^2 =
1.87In.W.C.
60 to 50hz Effect
60hz blower Gas Input 400,000; 8.3%
CO2; 1020HV
Static Pressure In. W.C (@ Std Air)
4.5
Blower Performance
system curve
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
50
100
CFM
150
200
60 to 50hz Effect
4.5
Blower Performance
system curve
50 hz performance
4.0
3.5
3.0
60 Hz flow pt
2.5
2.0
60 Hz flow
measured
1.5
1.0
50 Hz flow
fan law
0.5
20
40
60
80
100
CFM
120
140
160
180
60 to 50hz Result
50hz blower 83.3CFM
Gas Input 333,000 with original CO2 =
8.3% & 1020HV