Fully Packaged, 3 Pass, Smoke Tube, Oil / Gas Fired Steam Boiler

Capacity Range

Standard Design Pressure

1000 to 10000 kg/hr

10.54 & 17.5 kg/cm g

Unique design features


Fully packaged unit: Completely pre-insulated,

pre-wired and packaged unit with monobloc


burner and boiler mounted control panel.
Compact design: Specially designed for light oil
and gas firing, compact build ensures lower foot
print area.
Efficiency enhancement: Modular type finned
Corrugated furnace
Finned tube for economiser
tube economiser can be integrated with main unit
to enhance efficiency up to 94%.
Corrugated furnace: Increases heat transfer area, offers flexibility for thermal expansion and ensures minimal stress transfer to
tube plate.

Technical specifications
Description
Capacity (F&A 100C)
Design Pressure (SVLOP)
Efficiency
Diesel / Natural gas
Natural Gas (with Economiser)
Fuel
Fuel Firing System
Fuel Consumption
Diesel / Natural gas
Natural Gas (with Economiser)
Connected Electrical Load
Diesel
Natural Gas
Dimensions & Weight
A
B
C
D
E
F
G
Chimney Top Diameter
Dry Weight (10.54 / 17.5)
Flodded weight (10.54/17.5)

Unit
kg / hr
kg / cm2g

SM-10DL
1000

SM-15DL
1500

SM-20DL
2000

kg / hr / Nm3 / hr
Nm3 / hr

58/71
68

87/107
101

116/142
135

173/214
203

kW
kW

4.2
4.2

4.9
4.9

6.7
6.7

mm
mm
mm
mm
mm
mm
mm
mm
tonne
tonne

3840
2235
2653
1500
3325
2020
2160
350
4.5 / 5.0
8.7 / 9.2

4370
2350
2733
1850
3840
2150
2180
400
5.5 / 6.0
10.8 / 11.5

4602
2364
2727
1850
3825
2100
2300
400
5.8 / 6.5
10.9 / 11.6

%
%

SM-30DL
3000

SM-40DL
SM-50DL
4000
5000
10.54/17.5
As per BS 845 Part 1 NCV Basis
89
94
Diesel / Natural Gas
Pressure Jet, Mono Bloc (Make - Oilon)

SM-60DL
6000

SM-80DL
8000

SM-100DL
10000

289/357
338

347/428
405

462/571
541

578/714
676

9.0
9.0

231/285
270
10.54/17.5
11.0
11.0

13.5
12.0

17.0
15.5

19.2
17.0

28.5
24.5

5131
2456
2853
2200
4325
2100
2300
450
7.0 / 8.5
14.0 / 15.2

5420
2700
3273
2450
4625
2370
2660
550
9.1 / 10.7
18.5 / 20.0

5938
2848
3273
2700
4875
2400
2660
600
10.0 / 12.0
19.50 / 21.5

6608
2998
3473
3200
5425
2550
2810
650
12.0 / 14.0
24.5 / 26.5

7158
3079
3573
3600
5975
2650
2950
700
14.0 / 17.0
28.3 / 30.8

7698
3326
3838
4000
6475
2850
3150
800
17.0 / 20.5
35.7 / 39.0

Note :Design Standard-IBR. Efficiency is calculated based on NCV of Diesel as 10500 kcal/kg and Natural Gas as 8500 kcal/Nm. Economiser is recommended as HRU for NG firing. Above mentioned weight and dimensions
may vary with actuals. Please refer to offer document for more details.

General arrangement
Control Panel
Oilon Burner

Feed water pump

THERMAX LIMITED

Heating SBU, C&H Division


D-13, M.I.D.C. Industrial Area, R. D. Aga Road
Chinchwad, Pune - 411019, INDIA
Tel.: +91 - 20 - 27470436, 27475941/ 42, 66122100
Fax: +91 - 20 - 27472049
E-mail: heating.enquiries@thermaxindia.com
www.thermaxindia.com

D
A

THERMAX
SUSTAINABLE SOLUTIONS
ENERGY & ENVIRONMENT
Boilers & Heaters
Absorption Cooling
Captive Power

Water & Waste Solutions


Air Pollution Control
Chemicals

REGIONAL OFFICES n New Delhi n Mumbai n Kolkata n Chennai n Ahmedabad n Bangalore n Hyderabad n Pune INTERNATIONAL OFFICES n UK n USA n UAE n Germany
Arabia n Thailand n Malaysia n Phillipines n China n Brazil n Peru n Chile n Bangladesh n Srilanka n Kenya n Nigeria n Indonesia

n Belgium n Denmark n Russia n Saudi

In view of our constant endeavor to improve the quality of our products, we reserve the right to alter or change specifications without prior notice. All photographs shown in this publication are representative in purpose and are to be used for
reference purpose only. Whilst this information is given in good faith, no warranty or representation is given concerning such information which must not be taken for establishing any contractual or other commitment binding on Thermax
Ltd. For actual details and specifications, please refer the Thermax offer document.