Вы находитесь на странице: 1из 132

Pipe

Shields
Inc.

1.

2.

3.

4.
1. Cold insulated pipe anchors with axial stops.
2. Custom cryogenic pipe supports fabricated for an LNG facility.
3. 274 custom hot pipe shoes rush project which were delivered in
three weeks.
4. Insulated pipe supports designed for cryogenic temperatures
down to -320F in an LNG facility.

5.

5. Custom high temperature pipe supports for a granular activated


carbon manufacturing plant.

Pipe
Shields
Inc.

Pipe TABLE
Shields,
Inc.
OF CONTENTS

General Introduction....................................................................................................................................................

Temperature, Dimensional and Material Variances.................................................................................................

6-12

Use of the Insulated Pipe Support Selection Guide..............................................................................................



Table 1: Water Service-Pipe Supported from Above or Below.............................................................

Table 2: Steam/Gas/Air Service-Pipe Supported from Above or Below..............................................

Table 3: Water Service-Pipe Supported from Above in Clevis or 2-Bolt Hanger...............................

Table 4: Steam/Gas/Air Service-Pipe Supported from Above in Clevis or 2-Bolt Hanger..................

Table 5: Water Service-Pipe Supported from Below on Pipe Roll or Above.....................................

Table 6: Steam/Gas/Air Service-Pipe Supported from Below on Pipe Roll or Above......................

13-18
13
14
15
16
17
18

Section A: Pre-Insulated Pipe Support - Commerical & Light Industrial



Introduction/Index..................................................................................................................................................
Insulated Pipe Support.....................................................................................................................

Model A1000: Regular Duty...................................................................................................

Model A2000: Regular Duty w/ Extended Insulation...............................................................

Model A3000: Extra Heavy Bottom Jacket..............................................................................

Model A4000: Extra Heavy Bottom Jacket with exterior Insulation...........................................

Model A5000: With Load Distribution Plate.............................................................................

Model A6000: With Load Distribution Plate with exterior Insulation..........................................

Model A7000: Heavy Duty with Load Bearing Plate.................................................................

Model A7200: Heavy Duty with Load Bearing Plate.................................................................

Model A7400: Heavy Duty with Load Bearing Plate.................................................................

Model A8000: Heavy Duty with Load Bearing Plate.................................................................

Model A8200: Heavy Duty with Load Bearing Plate.................................................................

Model A8400: Heavy Duty with Load Bearing Plate.................................................................

Model A9000: Heavy Duty for use with Rod Hangers...............................................................

19-34
20-21
22-34
22
23
24
25
26
27
28
29
30
31
32
33
34

Section B: Pre-Insulated Pipe Support - Heavy Industrial - Base Mounted


Introduction/Index....................................................................................................................................................
Sliding Insulated Pipe Support-Heavy Duty, Base Mounted........................................................

Model B1000: .......................................................................................................................

Model B1100: ........................................................................................................................

Model B1200: .......................................................................................................................

Model B1300: ........................................................................................................................

Model B2000: ........................................................................................................................

Model B2100: ........................................................................................................................

Model B2200: ........................................................................................................................

Model B2300: .......................................................................................................................
Guided Insulated Pipe Support-Heavy Duty, Base Mounted.......................................................

Model B3000: ......................................................................................................................

Model B3100: ........................................................................................................................

Model B3200: ........................................................................................................................

Model B3300: ........................................................................................................................

Model B4000: ........................................................................................................................

Model B4100: ........................................................................................................................

35-47
36-39
40-47
40
41
42
43
44
45
46
47
48-55
48
49
50
51
52
53

Pipe
Shields
Inc.

Model B4200: .......................................................................................................................
54

Model B4300: .......................................................................................................................
55
Wide Base Sliding Insulated Pipe-Support-Heavy Duty, Base Mounted....................................... 56-63

Model B5000: .......................................................................................................................
56

Model B5100: .......................................................................................................................
57

Model B5200: .......................................................................................................................
58

Model B5300: .......................................................................................................................
59

Model B6000: .......................................................................................................................
60

Model B6100: .......................................................................................................................
61

Model B6200: .......................................................................................................................
62

Model B6300: .......................................................................................................................
63
Laterally Restrained Insulated Pipe Support-Heavy Duty, Base Mounted............................ 64-71

Model B7000: .......................................................................................................................
64

Model B7100: .......................................................................................................................
65

Model B7200: .......................................................................................................................
66

Model B7300: .......................................................................................................................
67

Model B8000: .......................................................................................................................
68

Model B8100: .......................................................................................................................
69

Model B8200: .......................................................................................................................
70

Model B8300: .......................................................................................................................
71
Section C: Insulated Pipe Support - Heavy Industrial - Anchors

Introduction/Index............................ ........................................................................................................................
Welded Tee Pipe Anchor Small Bore..............................................................................................

Model C1000, Model C1010, Model C1020, Model C1030.....................................................

Model C1100, Model C1110 , Model C1120, Model C1130.....................................................

Model C2000, Model C2010, Model C2020, Model C2030.....................................................

Model C2100, Model C2110, Model C2120, Model C2130 ....................................................
Insulated Friction Pipe Anchor .................................................................................................

Model C3000: .......................................................................................................................

Model C3100: .......................................................................................................................

Model C3200: .......................................................................................................................

Model C3300: .......................................................................................................................
Insulated Positive Anchor..............................................................................................................

Model C4000, Model C4010, Model C4020, Model C4030 ..................................................

Model C4100, Model C4110, Model C4120, Model C4130...................................................

Model C4200, Model C4210, Model C4220, Model C4230 ..................................................

Model C4300, Model C4310, Model C4320, Model C4330...................................................

Section D: Insulated Pipe Support - Heavy Industrial - Hung
Introduction/Index....................................................................................................................................................
Insulated 2-Bolt Hanger.....................................................................................................................

Model D1000......................................................................................................................

Model D2000:......................................................................................................................

Model D3000:.....................................................................................................................

Model D3100:.......................................................................................................................

Model D3200:.....................................................................................................................

Model D3300:.......................................................................................................................
Insulated 2-Rod Hanger.....................................................................................................................
Model D4000:....................................................................................................................

72-85
72-73
74-77
74
75
76
77
78-81
78
79
80
81
82-85
82
83
84
85
86-99
86-87
88-93
88
89
90
91
92
93
94-99
94

Pipe
Shields
Inc.




Model
Model
Model
Model
Model

95
96
97
98
99

D5000: ....................................................................................................................................
D6000: ....................................................................................................................................
D6100: ....................................................................................................................................
D6200: ....................................................................................................................................
D6300: ....................................................................................................................................
100-109
100-101
Section E: Insulated Pipe Support - Pipe Riser Clamp
Introduction/Index....................................................................................................................................................102-105
102
Insulated Pipe Riser Clamps for Downlward Loads......................................................................
103

Model E1000, Model E1010, Model E1020, Model E1030....................................................
104

Model E1100, Model E1110, Model E1120, Model E1130....................................................
105

Model E1200, Model E1210, Model E1220, Model E1230....................................................

Model E1300, Model E1310, Model E1320, Model E1330....................................................106-109
106
Insulated Pipe Riser Clamps for Upward or Downward Loads....................................................
107

Model E2000, Model E2010, Model E2020, Model E2030. ..................................................
108

Model E2100, Model E2110, Model E2120, Model E2130.....................................................
109

Model E2200, Model E2210, Model E2220, Model E2230....................................................

Model E2300, Model E2310, Model E2320, Model E2330 ...................................................
110-128
110-106
Section G: Pipe Clamps, Pipe Guide Straps, Pipe Guide U-Bolts
112
Introduction/Index.............................................................................................................................................
113

Model G1000: Pipe Shield Clamp.......................................................................................................
114

Model G1200: Pipe ClampTubing Clamp - Neoprene Sleeved...............................................................
115

Model G2000: Pipe Clamp Shield Guide Strap......................................................................................
116

Model G2200: Pipe ClampTubing Clamp - Neoprene Sleeved...............................................................

Model G3000: Pipe Guide U-Bolt Shield Guide U-Bolt............................................................................
119-125
Completed Projects...................................................................................................................................................
127-128
FrequentlyAsked Questions........................................................................................................................................

Pipe
Shields
Inc.

1.

2.

3.
1. Pre-insulated pipe shoes made with carbon steel.
2. High temperature support with an outside diameter of 58 and are
capable of handling temperatures up to 1500F. They are fabricated
from a combination of carbon steel for the top and stainless steel for
the bottom.

4.
4

3. 60 hot shoes for a chemical plant in Texas. These shoes are used
in processes where it is imperative that thermal energy is not lost
through the pipe support.
4. Hot shoes fabricated from steel carbon with a red oxide and
calcium sillicate insulation.

Pipe
Shields
Inc.

GENERAL INTRODUCTION

ipe Shields, Inc. pioneered the first insulated pipe support in 1971 for use on HVAC and plumbing lines.
These supports were designed because fiberglass pipe insulation is not strong enough to carry the load
at the point of support without crushing. The various methods contractors employed to compensate for this
weakness were inconsistent, non-uniform and labor intensive, often resulting in damage to the vapor barrier
and/or pipe insulation. The insulated pipe support filled the need for an energy efficient, economical and
practical support.
Pipe Shields, Inc. has developed a large and growing family of insulated pipe supports, using its standard
concept of incorporating materials strong enough to carry the load while insulating the pipe at the same
time. No welding to the pipe is required (except for insulated positive anchors and insulated pipe riser
clamps) and no direct metal-to-metal heat path exists. Insulated pipe supports meet an assortment of
requirements, including:

Pipe supported on:


o Flat Surface
o Pipe Roll
o Clevis Hanger
Gas
Steam
Super Heated Steam
Chilled Water
Styrene
Guide Supports
Sliding Supports
Restrained Supports

Anchors
Pipe Hangers
Pipe Riser Clamps
Thermal Growth Small or Large
Maximum Support Spacing
Light, Medium or Heavy Loads
Ultra-High Temperatures
Minimum Overhead Clearance
Minimum Horizontal Clearance
Minimum Field Labor
Minimum Friction Loads
Easy Installation

Other products designed, manufactured and supplied not included in this catalog are:
1.
2.
3.
4.

Seismic pipe restraints


Heat-traced pre-insulated pipe supports
Pipe supports used in computer chip, styrene plants and oil refineries
Pipe supports for solar energy projects to accommodate expansion travels in excess of
5- 0

Our highly sophisticated products are a direct result of years of research, engineering and
design to develop cost efficient products for the power, petrochemical, chemical and commercial
markets. We work closely with engineering firms and in-house engineering departments of
owners to provide working solutions to meet their engineering challenges. We have established
proprietary specifications that have now become an industry standard used by owners, engineers
and contractors throughout the world markets.
If you have a pipe support need not met by any of the items described in this catalog, please
contact us at
707-447-5014 or 1-800-538-7007.

Pipe
Shields
Inc.

TEMPERATURE, DIMENSIONAL AND MATERIAL VARIANCES

Temperature Ranges

Pipe Shields, Inc. strongly recommends the following temperature ranges for our standard insulation
material:
Material

Temperature

Calcium Silicate

+40oF to + 1200oF

Polyurethane

-275oF to +275oF

Permali/Insulam

-328oF to +248oF

Foamglas

-450oF to +900oF

Note: Can be increased to 1800F using higher density Calcium Silicate

Material Variances
Our standard paint finish is SP150 red oxide primer which meets full EPA and California safety regulations.
Other paint finishes are available upon request which include:





Hot dipped galvanized


Inorganic zinc (CZ11HS)
Dupont (Corlar) 25P epoxy
SP145 grey oxide
Carbothane 134HG
Carbozinc 859

Slide plate material and other field welded material are coated with deoxaluminate (silver coating).

Model Designation for Alternate Insulation Materials


Polyurethane Add U after Catalog Model Number
Urethane/Foamglas Add UF after Catalog Model Number
Calcium Silicate/Foamglas Add CF after Catalog Model Number

www.pipeshields.com/materials

Example: B1000U
Example: B1000UF
Example: B1000CF

Pipe
Shields
Inc.

Calcium Silicate

MATERIALS

Calcium Silicate often serves as the insulation for pipe supports in high temperature applications. Calcium
Silicate is also known as Thermo-12/Gold. It is an insulating material composed of hydrous calcium silicate
which, because of its light weight, low thermal conductivity and exceptional structural strength is ideal for
the insulation of high temperature piping and equipment. Sometimes it is also used as block insulation. The
pipe insulation comes in a complete selection of sizes. Block styles are available for application to various
flat and curved surface areas.
Some of Calcium Silicates major advantages and applications are given below:
Major Advantages:
Temperature Range to 1200F
Exceptional Strength
Low Thermal Conductivity
Easy Application: available sizes and shapes reduce the number of required joints and make
Calcium Silicate easy to work with.
Energy Savings: low thermal conductivity provides significant energy savings.
Adaptable: Calcium Silicate can also be used on a various shapes and sizes of surfaces.
Fire Resistant
Low Chloride Content: low corrosivity
Asbestos-Free
Major Applications:
Hot Line Pipe Supports in Power Generation and Process Industries.
Indoor and Outdoor Piping and Equipment.
Block Insulation - insulation of various flat and curved surface areas.

Polyurethane
Polyurethane is different from most plastic materials in that it can be tailored to meet various load
requirements of varying applications. Polyurethane foams are produced by reacting an equal ratio
of di- or polyisocyanurates with polyols, in the presence of water, which acts as the blowing agent.
Polyisocyanurates are formed when a higher ratio of di- or polyisocyanate are mixed with the polyol. All
rigid foams made from polyisocyanrate systems have some form of polyurethane in them and can be
called polyurethane foam. The physical properties differ very little at high densities. Polyisocyanurate
foams are used in applications where dimensional stability over 200oF is
required. However, for cryogenic applications, where your pipeline insulation
is not exposed to high temperatures, PUF is an acceptable substitution.
A common method used to obtain a change in load capacity is a change in
density. At Pipe Shields, we offer 10 lbs. / ft3, 14 lbs. / ft3, and 20 lbs. / ft3
densities.
Density varies when the amount of blowing agent (water content) changes.
The density of polyurethane decreases with increase in water content (See
Fig. 1). This relationship can be shown as follows:
W = 3.706 / D1.126
Where: W = % of water content
D = Density of foam (lbs./ft3.)

Pipe
Shields
Inc.
In addition to density, the strength of a rigid urethane foam is also influenced by many factors such as
catalyst, surfactant, type of mixing, the type of foaming system: base polyol and isosyanate, and the
influence of each of these on the foam cell structure.
Rigid urethane foams generally have an elastic region in which stress is nearly proportional to strain. They
do not exactly follow Hookes Law (stress is proportional to strain) because the curve is very slightly S
shaped. Fig. 2 shows this in detail.
Polyurethane is anisotropic, or polyurethane is stronger in the direction of foam rise. At Piping Technology
and Products, the anisotropic character or directional properties of our polyurethane is reduced by
overloading the mold used to form the polyurethane. By overloading the mold, we can control the cell
structure and provide uniform physical properties. A relationship between compressive strength and the
density of the foam is given in Fig. 3.

effects.

Polyurethane is a thermosetting
material; however, it does soften
slightly with increased temperature
and hardens somewhat at very low
temperatures. Softening at high temperatures
affects the polyurethane in two ways:
(a) loss of strength properties and (b)
change in foam dimensions (particularly lowdensity foams). Low temperatures generally
have very little effect on polyurethane
properties other than to make them a little
harder and more brittle. See Fig. 4 for these

Rigid polyurethane foams have a relatively large amount of cross-linking as the foam expands. Our
suppliers of the raw chemicals control the degree of cross-linking by functionality (higher functionality
produces more cross-links) and molecular weight of the components in the blend. The rigid cells provide the
poured foam with strength and the interior space provides low thermal conductivity. Water is used as the
blowing agent for foam in this 10 to 40 lb. density range.
The relationship between temperature,
thermal conductivity and the density of
polyurethane foam is shown in Fig. 5.
The relationships of foams density with
its Elastic Modulus in Compression,
Tensile Strength, Elastic Modulus in
Tension, and Shear Strength are given
in Figs. 6 through 9 respectively. Please
see the following for the respective
curves.
Pipe Shields has a complete
manufacturing facility for production
of polyurethane required for pipe supports. We invite our customers to visit our facility and observe the
fabrication of insulated pipe supports of all types.

Pipe
Shields
Inc.
DENSITY

COMPRESSIVE
STRENGTH
(psi)

FLEXURAL
STRENGTH
(flatwise with
grain) (psi)

TENSILE
TRENGTH
(with grain)
(psi)

MODULUS OF
ELASTICITY
(psi)

CLOSED
CELL
CONTENT
(%)

TEMPERA-

THERMAL
CONDUCTIVITY (btu/hr m^2

DENSITY
(lb/in^3)

F)

SHEAR
(flatwise
1/8" thk.
Psi)

WATER
ABSORPTION (%)

PUF
(10pcf)

200

400

300

6,000.00

95

-300

0.08

0.16

180

0.1157

0.22

PUF
(14pcf)

300

600

500

11,000.00

95

-300

0.12

0.2

200

0.1736

0.18

PUF
(20pcf)

500

1,100.00

600

20,000.00

95

-300

0.14

0.25

400

0.2893

0.13

TURE (F)
CONTINUOUS
OPERATION

K-FACTOR

Foamglas
Foamglas insulation is a lightweight, rigid insulation composed of millions of completely sealed glass
cells. Each cell serves as an insulating agent. Foamglas is widely used in the cryogenic and hot line
pipe supports and is fabricated in various ranges of shapes, thicknesses and sizes to meet the particular
requirements of an application.
One unique advantage that Foamglas has is its very low moisture absorption. Since, Foamglas insulation
is full of closed glass cells, it resists moisture in both liquid and vapor form. This guarantees the long
term performance of the insulation. Foamglas insulations resistance to moisture ensures that, properly
installed, it retains its original thermal efficiency.
The major advantages and applications of Foamglas insulation are listed below. For details about the
physical and mechanical properties of the Foamglas material, please refer to the table.
Major Advantages:
Constant Insulating Efficiency
Fire Protection
Corrosion Resistance
Long Term Dimensional Stability
Physical Strength
Major Applications:
Cryogenic and Hot Line Pipe Supports
Cryogenic Tanks and Vessels
Chilled and Hot Water Service Lines
Overfit and Revitalize the Old Insulation
Composite Insulation Systems for Special Conditions

Pipe
Shields
Inc.
Density

Foamglas (8 pcf)

Compressive Strength (psi)

100.00

Flexural Strength (flat wise with grain) (psi)

80.00

Tensile Strength (with grain)(psi)

N/A

Modulus of Elasticity (psi)

1.4 10^5

Closed Cell Content (%)

N/A

Temperature (F)-Continuous Operation

500 max.

K-Factor

N/A

Thermal Conductivity (btu-in/HR-ft^2-F)

0.32

Shear (flat wise) (1/8" thk.) (psi)

N/A

Density (lb/in^3)

0.0046

Water Absorption (%)

0.2%

Permali or Insulam or Laminated Beechwood


Permali or Insulam or Laminated Beechwood is an insulating material used in applications which
require high tensile and compressive strength (see table below). In addition, due to its exceptional
resistance to moisture, it serves as a suitable insulator where the support (flare lines & dummy legs)
is exposed to harsh environment elements. Permali or Insulam is a phenolic laminated (densified,
impregnated wood) product made from carefully selected thin beechwood veneers. These wood layers
are impregnated under vacuum conditions with a special synthetic resin and then densified through the
application of heat and pressure. The result is a homogenous material that combines the great strength
and toughness of wood fibers with the excellent stability and dielectric properties of the most advanced
thermosetting. The phenolic laminated block material is furnished with cross-directional fibers as shown
in the figure.

NOTE: Cross laminated.


For components in compression or for
parts stressed in more than one direction.
Sizes to suit most applications.

10

Density

Permali (82 pcf)

Compressive Strength (psi)

30,000.00

Flectual Strength (flatwise with grain) (psi)

15,000.00

Tensile Strength (with grain)(psi)

15,000.00

Modulus of Elasticity (psi)

2.0 x 10^6

Closed Cell Content (%)

N/A

Temperature(F)-Continuous Operation

221.00

K-Factor

N/A

Thermal Conductivity (btu/hr m^2 F)

0.0018

Shear (flatwise) (1/8 thick) (psi)

7200.00

Density (lb/in^3)

0.0469

Water Absorption (%)

0.75

Pipe
Shields
Inc.

Foamglas Technical Information


Foamglas insulation is a lightweight, rigid insulation composed of millions of completely sealed glass
cells. Each cell serves as an insulating agent. Foamglas is widely used in the cryogenic and hot line
pipe supports and is fabricated in various ranges of shapes, thicknesses and sizes to meet the particular requirements of an application.
One unique advantage that Foamglas has is its very low moisture absorption. Since, Foamglas insulation is full of closed glass cells, it resists moisture in both liquid and vapor form. This guarantees the
long term performance of the insulation. Foamglas insulations resistance to moisture ensures that,
properly installed, it retains its original thermal efficiency.
The major advantages and applications of Foamglas insulation are listed below. For details about the
physical and mechanical properties of the Foamglas material, please refer to the table.
Major Advantages:
Constant Insulating Efficiency
Fire Protection
Corrosion Resistance
Long Term Dimensional Stability
Physical Strength
Major Applications:
Cryogenic and Hot Line Pipe Supports
Cryogenic Tanks and Vessels
Chilled and Hot Water Service Lines
Overfit and Revitalize the Old Insulation
Composite Insulation Systems for Special ConditionsFoamglas Technical Information
Foamglas insulation is a lightweight, rigid insulation composed of millions of completely sealed glass
cells. Each cell serves as an insulating agent. Foamglas is widely used in the cryogenic and hot line
pipe supports and is fabricated in various ranges of shapes, thicknesses and sizes to meet the
particular requirements of an application.
Density

Foam Glass(8 pcf)

Compressive Strength (psi)

400.00

Flexural Strength (flat wise with grain) (psi)

80.00

Tensile Strength (with grain)(psi)

N/A

Modulus of Elasticity (psi)

1.3 10^6

Closed Cell Content (%)

N/A

Temperature (F)-Continuous Operation

500 max.

K-Factor

N/A

Thermal Conductivity
(btu/hr m^2 F)

0.7000

Shear (flat wise) (1/8 thk.) (psi)

N/A

Density (lb/in^3)

0.0046

Water Absorption (%)

0.070

11

Pipe
Shields
Inc.

Insulated Pipe Support Selection Guide

USE OF THE INSULATED PIPE SUPPORT SELECTION GUIDE


The tables on the following pages will assist you in making a selection of the proper and most economic
insulated pipe support for your application.
These Selection Guide Tables are organized by:
1. SERVICE
A. Water
B. Steam, Gas, or Air
2. APPLICATION
A. Pipe supported from below
a. On flat surface
b. On pipe roll
B. Pipe supported from above
a. In clevis or 2-bolt hanger

Service

Configuration

Water

Support from Above

Clevis or 2-bolt clamp

View Selection Table 3

Support from Below

On Flat Surface

View SelectionTable 1

On Pipe Roll

View Selection Table 5

Support from Above

Clevis or 2-Bolt Clamp

View Selection Table 4

Support from Below

On Flat Surface

View Selection Table 2

On Pipe Roll

View Selection Table 6

Steam, Gas, or Air

Spacing Guide

The product data sheets describing each model refer to other models in the catalog with features such as
load rating, axial or lateral travel, or restraint, etc. which you may have an interest.
If you have a pipe support need not met by any of the items described in this catalog, please contact us at
707-447-5014 or 1-800-538-7007.

12

www.pipeshields.com/selectionguide

Pipe
Shields
Inc.

Insulated Pipe Support Selection Guide


TABLE 1
SERVICE:

WATER

APPLICATION: PIPE SUPPORTED FROM ABOVE OR BELOW


Pipe Shields Model:
Commercial
Pipe Size
(inches)

Light Industrial

Heavy Industrial

Rated for Combined

w/ Load Distribution Plate

on Slide Pad

Lateral and Vertical Loads

For
reference:
ASME
B31.1

A1000
A2000

A3000
A4000

A5000
A6000

A7000

A7200

A7400

B1000
B2000
B3000
B4000
B5000
B6000

B1100
B2100
B3100
B4100
B5100
B6100

B1200
B2200
B3200
B4200
B5200
B6200

B1300
B2300
B3300
B4300
B5300
B6300

B7000
B8000

B7100
B8100

B7200
B8200

B7300
B8300

maximum hanger support spacing (feet)


1/2
3/4

7
7

11
12

12
13

1
1 1/2
2
2 1/2

7
9
10
11

13
15
15
12

14
16
17
14

16

21

3
3 1/2
4
5

12
13
14
16

12
12
13
12

13
13
14
14

17
16
17
16

20
19
19
17

6
8
10
12

17
19
22
23

10
7
6

12
8
6

13
11
7
8

14
12
10
14

26
21
18
20

14
16
18
20

25
27
28
30

13
12
10
9

24
60
63
42

32
33
35
36

35
35
35
35

45
45
45
45

55
55
55
55

32
33
35
33

45
45
45
45

55
55
55
55

25
31

34
29
24
20

45
45
45
40

55
55
55
55

65

30
26
21
17

45
45
42
36

55
55
55
54

64

22
21
19
17

31
28
26
23

20
19
17
15

40
37
34
31

55
55
52
46

65
65
65
62

18
16
15
14

35
34
30
27

53
50
46
41

65
65
61
55

14
10

18
12

12
11
9
8

24
21
18
16

36
32
28
24

48
43
37
32

10
9
8
7

21
19
16
14

32
29
24
21

43
39
33
28

Note: The maximum hanger spacing shown in Table 1 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc.
models, assuming weight of standard pipe, water, and 2 insulation. The customer should be guided by the hanger spacings allowed
by the applicable code or the project engineers specifications before making a selection. Refer to the appropriate Product Data
Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.
Example: Given:

Pipe Diameter: 8 standard weight

Service:

Water

Support Spacing:

20 - 0

Determine:

Insulated pipe support model number

Method:
In table 1, for 8 pipe size, find the model(s) rated for handling 20- 0 or greater support spacing. In
this case, Model A7200 is selected since it is capable of handling 21-0 support spacing. The Index Sheets to Sections A & B
indicate some of the differences between models. Check Product Data Sheet for description before making a final selection. In
this example, if the support is required to handle +/-4 1/2 of axial travel, Model B2000 would be selected (Section B Index &
Product Data Sheet B2000).

www.pipeshields.com/table1

13

Pipe
Shields
Inc.

Insulated Pipe Support Selection Guide


TABLE 2

SERVICE:

STEAM, GAS OR AIR

APPLICATION: PIPE SUPPORTED FROM ABOVE OR BELOW

Pipe Shields Model:


Commercial
Pipe Size
(inches)

Light Industrial

Heavy Industrial

Rated for Combined

w/ Load Distribution Plate

on Slide Pad

Lateral and Vertical Loads

For
reference:
ASME
B31.1

A1000
A2000

A3000
A4000

A5000
A6000

A7000

A7200

A7400

B1000
B2000
B3000
B4000
B5000
B6000

B1100
B2100
B3100
B4100
B5100
B6100

B1200
B2200
B3200
B4200
B5200
B6200

B1300
B2300
B3300
B4300
B5300
B6300

B7000
B8000

B7100
B8100

B7200
B8200

B7300
B8300

maximum hanger support spacing (feet)


1/2
3/4

8
9

11
12

12
13

1
1 1/2
2
2 1/2

9
12
13
14

14
17
18
15

15
19
20
16

20

25

3
3
1/2
4
5

15
16
17
19

15
16
17
17

17
18
19
20

21
21
23
22

26
25
26
25

6
8
10
12

21
24
26
30

16
12
10
9

18
14
10
9

20
17
13
15

22
19
17
26

40
35
31
37

14
16
18
20

32
35
37
39

8
8

9
8

15
14
14
14

25
24
24
22

24
60
63
42

42
44
48
50

11
10
9

20
18
15
12

40
40
40
40

50
50
50
50

60
60
60
60

40
40
40
40

50
50
50
50

60
60
60
60

40
45

40
40
40
36

50
50
50
50

60
60
60
60

70

40
40
36
32

50
50
50
50

60
60
60
60

70

40
40
40
40

45
45
45
45

38
39
38
36

50
50
50
50

60
60
60
60

70
70
70
70

34
25
34
32

50
50
50
50

60
60
60
60

70
70
70
70

36
32
27
23

45
39

32
33
33
31

50
50
50
50

60
60
60
60

70
70
70
70

28
30
29
28

50
50
50
50

60
60
60
60

70
70
70
70

Note: The maximum hanger spacing shown in Table 2 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc.
models, assuming weight of standard pipe, and 2 insulation. The customer should be guided by the hanger spacings allowed by the
applicable code or the project engineers specifications before making a selection. Refer to the appropriate Product Data Sheets for
additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.
Example: Given:

Service:

Steam

Support Spacing:

30 - 0

Determine:

14

Pipe Diameter: 8 standard weight

Insulated pipe support model number

Method:
In table 2, for 8 pipe size, find the model(s) rated for handling 30- 0 or greater support spacing. In
this case, Model A7200 is selected since it is capable of handling 35-0 support spacing. The Index Sheets to Sections A & B
indicate some of the differences between models. Check Product Data Sheet for description before making a final selection. In
this example, if the support is required to handle +/-4 1/2 of axial travel, Model B2000 would be selected (Section B Index &
Product Data Sheet B2000).

www.pipeshields.com/table2

Pipe
Shields
Inc.

Insulated Pipe Support Selection Guide


TABLE 3
SERVICE:

WATER

APPLICATION: PIPE SUPPORTED FROM ABOVE IN CLEVIS OR 2-BOLT HANGER

Pipe Shields Model:


Clevis Hanger
Pipe Size
(inches)

2-Bolt Hanger

For
reference:
ASME
B31.1
A1000
A2000

A3000
A4000

A9000

D1000
D2000
D4000
D5000

D3000
D6000

D3100
D6100

D3200
D6200

D3300
D6300

maximum hanger support spacing (feet)


1/2
3/4

7
7

11
12

12
13

13
15

1
1 1/2
2
2 1/2

7
9
10
11

14
16
17
16

15
18
18
18

17
19
21
21

19
22
29
24

3
3 1/2
4
5

12
13
14
16

17
16
16
15

18
17
18
16

20
19
19
19

25
22
22

6
8
10
12

17
19
22
23

14
13
12
11

15
13
13
12

14
16
18
20

25
27
28
30

11
10
9
9

24
30

32
33

21

40

16
15
14
13

21
22
24
22

40
32
28
26

12
11
10
9

13
12
11
10

20
21
18
16

23
26
22
18

40
33
28

37

15
11

19
13

29
19

38
26

Note: The maximum hanger spacing shown in Table 3 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc.
models, assuming weight of standard pipe, water, and 2 insulation. The customer should be guided by the hanger spacings allowed
by the applicable code or the project engineers specifications before making a selection. Refer to the appropriate Product Data
Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.
Example: Given:

Pipe Diameter: 8 standard weight

Service:

Water

Support Spacing:

20 - 0

Determine:

Insulated pipe support model number

Method:
In table 3, for 8 pipe size, find the model(s) rated for handling 20- 0 or greater support spacing. In
this case, Model D3000 is selected since it is capable of handling 22-0 support spacing. The Index Sheets to Sections A & D
indicate some of the differences between models. Check Product Data Sheet for description before making a final selection. In
this example, if the clearance is above the support limited, Model D6000 might be selected (Section D Index & Product Data
Sheet D6000).

www.pipeshields.com/table3

15

Pipe
Shields
Inc.

Insulated Pipe Support Selection Guide


TABLE 4

SERVICE:

STEAM, GAS OR AIR

APPLICATION: PIPE SUPPORTED FROM ABOVE IN CLEVIS OR 2-BOLT HANGER

Pipe Shields Model:


Clevis Hanger
Pipe Size
(inches)

2-Bolt Hanger

For
reference:
ASME
B31.1

A1000
A2000

A3000
A4000

A9000

D1000
D2000
D4000
D5000

D3000
D6000

D3100
D6100

D3200
D6200

D3300
D6300

maximum hanger support spacing (feet)


1/2
3/4

8
9

11
12

12
13

13
15

1
1 1/2
2
2 1/2

9
12
13
14

15
19
20
20

16
20
22
22

19
22
25
25

21
26
36
29

3
3 1/2
4
5

15
16
17
19

21
21
23
22

24
23
24
24

26
25
26
28

32
29
31

30

55

6
8
10
12

21
24
26
30

22
21
20
20

23
22
22
21

24
25
24
24

32
25
40
40

55
52
45
45

14
16
18
20

32
35
37
39

21
21
21
21

23
22
22
22

25
25
25
25

38
40
40
38

55
55
49
44

60
60
60
60

65

24
30

42
44

20

21

24

40
34

50
51

60
60

65
65

Note: The maximum hanger spacing shown in Table 4 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc.
models, assuming weight of standard pipe, and 2 insulation. The customer should be guided by the hanger spacings allowed by the
applicable code or the project engineers specifications before making a selection. Refer to the appropriate Product Data Sheets for
additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.
Example: Given:

Pipe Diameter: 8 standard weight

Service:

Steam

Support Spacing:

24 - 0

Determine:

16

Insulated pipe support model number

Method:
In table 4, for 8 pipe size, find the model(s) rated for handling 24- 0 or greater support spacing. In
this case, Model A9000 is selected since it is capable of handling 25-0 support spacing. The Index Sheets to Sections A & D
indicate some of the differences between models. Check Product Data Sheet for description before making a final selection. In
this example, if the clearance is above the support limited, Model D6000 might be selected (Section D Index & Product Data
Sheet D6000).

www.pipeshields.com/table4

Pipe
Shields
Inc.

Insulated Pipe Support Selection Guide


TABLE 5
SERVICE:

WATER

APPLICATION: PIPE SUPPORTED FROM BELOW ON PIPE ROLL OR ABOVE

Pipe Shields Model:


Commerical
Pipe Size
(inches)

Light Industrial w/ Load Distribution Plate

For reference: ASME


B31.1
A3000
A4000

A5000
A6000

A8000

A8200

A8400

maximum hanger support spacing (feet)


1/2
3/4

7
7

12
13

1
1 1/2
2
2 1/2

7
9
10
11

13
15
15
12

3
3 1/2
4
5

12
13
14
16

12
12
13

6
8
10
12

17
19
22
23

14
16
18
20

25
27
28
30

24
30

32
33

15

18

15
12
15
14

17
16
16
15

12
9

13
10
10
12

24
19
16
23

22
31

11
10
9
8

21
19
17
15

28
25
23
20

12
9

16
12

Note: The maximum hanger spacing shown in Table 5 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc.
models, assuming weight of standard pipe, water, and 2 insulation. The customer should be guided by the hanger spacings allowed
by the applicable code or the project engineers specifications before making a selection. Refer to the appropriate Product Data
Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.
Example: Given:

Pipe Diameter: 8 standard weight

Service:

Water

Support Spacing:

18 - 0

Determine:

Insulated pipe support model number

Method:
In table 5, for 8 pipe size, find the model(s) rated for handling 18- 0 or greater support spacing. In
this case, Model A8200 is selected since it is capable of handling 19-0 support spacing. The Index Sheet to Section A indicates
some of the differences between models. Check Product Data Sheet for description before making a final selection. If greater
support spacings are desired, see Section B (Base Mounted Supports).

www.pipeshields.com/table5

17

Pipe
Shields
Inc.

Insulated Pipe Support Selection Guide


TABLE 6

SERVICE:

STEAM, GAS OR AIR

APPLICATION: PIPE SUPPORTED FROM BELOW ON PIPE ROLL OR ABOVE

Pipe Shields Model:


Commerical
Pipe Size
(inches)

Light Industrial w/ Load Distribution Plate

For reference: ASME


B31.1
A3000
A4000

A5000
A6000

A8000

A8200

A8400

maximum hanger support spacing (feet)


1/2
3/4

8
9

12
13

1
1 1/2
2
2 1/2

9
12
13
14

14
17
18
15

3
3 1/2
4
5

15
16
17
19

15
16
17

6
8
10
12

18

22

19
19
20
20

21
21
23
22

21
24
26
30

18
15
11
13

20
17
17
23

36
31
27
40

38
50

14
16
18
20

32
35
37
39

13
13
12
12

22
22
21
20

40
39
38
36

50
50
50
49

24
30
36
42

42
44
48
50

11
9
8

18
16
13
11

33
29
24
20

44
39

Note: The maximum hanger spacing shown in Table 6 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc.
models, assuming weight of standard pipe, and 2 insulation. The customer should be guided by the hanger spacings allowed by the
applicable code or the project engineers specifications before making a selection. Refer to the appropriate Product Data Sheets for
additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.
Example: Given:

Pipe Diameter: 8 standard weight

Service:

Water

Support Spacing:

25 - 0

Determine:

18

Insulated pipe support model number

Method:
In table 6, for 8 pipe size, find the model (s) rated for handling 25-0 or greater support spacing. In
this case, Model A8200 is selected since it is capable of handling 25-0 or 31-0 support spacing. The Index Sheet to Section A
indicates some of the differences between models. Check Product Data Sheet for description before making a final selection. If
greater support spacings are desired, see Section B (Base Mounted Supports).

www.pipeshields.com/table6

Pipe
Shields
Inc.

19

Pipe
Shields
Inc.

Introduction: Section A

INTRODUCTION
SECTION A
PRE-INSULATED PIPE SUPPORTS
APPLICATION Commercial and Light Industrial
Most commercial applications are well served by Models A1000 and A2000, which are recommended for
use on common 10-0 hanger space for small bore pipe sizes (see Selection Guide). However, should the
need arise, because of increased hanger spacing or the manner in which the insulated support is mounted,
heavier duty supports are available.
As is readily seen in the Section Index on the following page, some models are meant for installation
only in a clevis hanger, on a flat surface, or on a pipe roll. Other models may be installed in any two or
all three mounting methods.
The load ratings (see Product Data Sheets) reflect consideration for the manner in which each of these
models will be mounted.
Note: In the A7000 through A7400 Series and the A8000 through A8400 Series, the higher the
model number, the higher the load rating.
We are committed to providing the most economical and appropriate insulated pipe support to satisfy the
requirements of the piping system.
If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at
707-447-5014 or 1-800-538-7007.

Please acquaint yourself with the selection guide at the front of this catalog and the section index on
the page following this introduction, for assistance in determining the most appropriate support for your
application.

20

Pipe
Shields
Inc.

Section A Index
PRE-INSULATED PIPE SUPPORTS

COMMERCIAL AND LIGHT INDUSTRIAL


MODEL

A1000
A2000
A3000
A3000
A4000
A4000

1/2 - 24
1/2 - 24
1/2 - 24
1/2 - 4
1/2 - 24
1/2 - 4

A5000
A6000
A7000
A7200
A7400
A8000
A8200
A8400

2 1/2 - 42
2 1/2 - 42
2 1/2 - 42
6 - 42
10 - 30
2 1/2 - 42
6 - 42
10 - 30

X
X
X
X
X
X
X

X
X
X
X
X
X
X

A9000

1/2 - 24

A1000, A3000, A9000

A5000, A7000 - A8400

A1000, A3000, A9000

PRIMARY
APPLICATION
HOT
COLD

PIPE
SIZE
RANGE

X
X
X

INSTALLED ON
FLAT
CLEVIS
SURFACE HANGER

X
X
X

PIPE
ROLL

X
X
X
X

X
X

X
X

X
X
X
X
X

X
X

X
X
X

DUTY

LIGHT
LIGHT
MEDIUM
MEDIUM
MEDIUM
MEDIUM

MED/HEAVY
MED/HEAVY
HEAVY
HEAVIER
HEAVIEST
HEAVY
HEAVIER
HEAVIEST

HEAVY

TO ORDER, specify:
1. Quantity 20
2. Pipe Size & Type
2 IPS
3. Insulation Thickness
2-1/2
4. Model Number
A1000
EXAMPLE:(20) 2 x 2-1/2
A1000

www.pipeshields.com/a-series

21

A1000, A3000, A9000

Pipe
Shields
Inc.A1000, A3000, A9000

Model A1000 Insulated Pipe Support Regular Duty

Pipe
Size
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24

A
INCHES

Oper.
Temp.
o
F

Hardware sold separately.


Note: For higher load ratings, see A3000, A9000.

Mult.
Factor
"F"

500
0.90
750
0.75
1000
0.50
1200
0.30
TABLE III

The load ratings represent average values obtained in accordance with accepted
methods and are subject to normal manufacturing variations. Dimensions and ratings
are subject to change without notice.
a) To develop maximum load rating, width of support surface should be at
least 1/2 of dimension A in Table II.
b) To develop maximum load rating, use band, ring or clevis hanger with
manufacturers load rating equal to or greater than values shown in Table I.

Contact factory for other dimensions,


temperatures, and loads.
Available in all insulation thicknesses.

c) To obtain load ratings for operating temperatures of 500 F and higher,


multiply load rating by factor F in Table III.
Iron
Pipe
Size
1/2 - 1 1/2
2
2 1/2 - 4
5
6-7
8 - 10
12 - 18
20 - 24

A
4
6
6

1/2

B
24
24
20

A
4
6
6

3/4

B
24
24
20

Insulation Thickness
1 1/2
2
2 1/2
3
B
A
B
A
B
A
B
A
B
24
4
24
4
24
4
24
6
24
24
6
24
6
24
6
24
6
24
20
6
20
6
20
6
20
9
20
20
6
20
6
20
6
20
9
20
20
6
20
6
20
6
20
9
16
9
16
9
16
9
16
9
16
12 16 12 16 12 16 12 16
18 16 18 16 18 16 18 16
TABLE II "B" = gauge of sheet metal jacket

3 1/2
A
B
6
24
6
24
9
20
9
20
9
16
9
16
12 16
18 16

A
6
6
9
9
9
9
12
18

B
24
24
20
20
16
16
16
16

Copper
Tubing
Size O.D.
5/8 - 1 5/8
2 1/8
2 5/8 - 4 1/8
5 1/8
6 1/8
8 1/8 -10 1/8
12 1/8

Application:

Features:

Material Data:

Model A1000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Minimizes heat loss and/or condensation
Copper tubing sizes available
Other I.D.s and/or O.D.s available on request

A1000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces
Band, ring or clevis pipe hanger

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A1000U)

22

A
4
6
6
6
6

MAXIMUM LOAD
RATING (LBS)
On Flat
In Clevis
Surface
Hanger
(a) (c)
(b) (c)
35
40
40
45
60
65
70
80
100
110
125
140
150
200
180
250
225
300
270
350
350
450
400
550
450
750
500
1000
550
1200
575
1400
600
1600
625
1800
675
2000
750
2300
TABLE I

Standard Insulation: Calcium silicate


asbestos-free, treated with water
repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive

Clamps available (see G-series)


Clevis available (see PTP fig. 83)

Formal submittal sheets available.

Performance test results on file:


Available upon request.

www.pipeshields.com/a1000

Pipe
Shields
Inc.

A2000, A4000

A1000, A3000, A9000

Model A2000 Insulated Pipe Support

Regular Duty with


Extended Insulation
1"
TYP

Pipe
Size
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24

A
INCHES

Oper.
Temp.
o
F

Hardware sold separately


Note: For higher load ratings, see A4000, A9000.

Mult.
Factor
"F"

500
0.90
750
0.75
1000
0.50
1200
0.30
TABLE III

The load ratings represent average values obtained in accordance with accepted
methods and are subject to normal manufacturing variations. Dimensions and ratings
are subject to change without notice.
a) To develop maximum load rating, width of support surface should be at
least 1/2 of dimension A in Table II.
b) To develop maximum load rating, use band, ring or clevis hanger with
manufacturers load rating equal to or greater than values shown in Table I.

Contact factory for other dimensions, temperatures,


and loads.
Available in all insulation thicknesses.

c) To obtain load ratings for operating temperatures of 500F and higher,


multiply load rating by factor F in Table III.
Iron
Pipe
Size
1/2 - 1 1/2
2
2 1/2 - 4
5
6-7
8 - 10
12 - 18
20 - 24

A
6
6
6

1/2

B
24
24
20

A
6
6
6

3/4

B
24
24
20

A
6
6
6
6
6

MAXIMUM LOAD
RATING (LBS)
On Flat
In Clevis
Surface
Hanger
(a) (c)
(b) (c)
35
40
40
45
60
65
70
80
100
110
125
140
150
200
180
250
225
300
270
350
350
450
400
550
450
750
500
1000
550
1200
575
1400
600
1600
625
1800
675
2000
750
2300
TABLE I

Insulation Thickness
1 1/2
2
2 1/2
3
B
A
B
A
B
A
B
A
B
24
6
24
6
24
6
24
6
24
24
6
24
6
24
6
24
6
24
20
6
20
6
20
6
20
9
20
20
6
20
6
20
6
20
9
20
20
6
20
6
20
6
20
9
16
9
16
9
16
9
16
9
16
12 16 12 16 12 16 12 16
18 16 18 16 18 16 18 16
TABLE II B = gauge of sheet metal jacket

3 1/2
A
B
6
24
6
24
9
20
9
20
9
16
9
16
12 16
18 16

A
6
6
9
9
9
9
12
18

B
24
24
20
20
16
16
16
16

Copper
Tubing
Size O.D.
5/8 - 15/8
2 1/8
2 5/8 - 4 1/8
5 1/8
6 1/8
8 1/8 -10 1/8
12 1/8

Application:

Features:

Material Data:

Model A2000 is designed for use on:


Cold water
Chilled water

Compact

A2000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces
Band, ring or clevis pipe hanger

Minimizes heat loss and/or condensation

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A2000U)

www.pipeshields.com/a2000

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Calcium silicate insulation extends 1 beyond the
galvanized sheet metal jacket providing for an
easier vapor barrier joint with the pipe insulation
Copper tubing sizes available

Insulation: Calcium silicate asbestosfree, treated with water repellant


Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Formal submittal sheets available.

Other I.D.s and/or O.D.s available on request


Clamps available (see G-series)
Clevis available (see PTP fig. 83)
Performance test results on file:
Available upon request.

23

A1000, A3000, A9000


PipeA1000, A3000, A9000
Shields
Inc.

Model A3000 Insulated Pipe Support

Pipe
Size
A
INCHES

Oper.
Temp.
o
F

Hardware sold separately


Note: For higher load ratings, see A5000, A9000.

Mult.
Factor
"F"

500
0.90
750
0.75
1000
0.50
1200
0.30
TABLE III

The load ratings represent average values obtained in accordance with accepted
methods and are subject to normal manufacturing variations. Dimensions and
ratings are subject to change without notice.
a) To develop maximum load rating, width of support surface should be at
least 1/2 of dimension A in Table II.
b) Divide A in Table II by 6 to find maximum allowable travel on pipe roll
(+/- from centered position).
c) To develop maximum load rating, use band, ring or clevis hanger with
manufacturers load rating equal to or greater than values shown in Table I.
d) To obtain load ratings for operating temperatures of 500F and higher,
multiply load rating by factor F in Table III.
Iron
Pipe
Size
1/2 - 1 1/2
2
2 1/2 - 4
5
6-7
8 - 10
12 - 18
20 - 24

A
4
6
6

1/2

B
24
24
20

A
4
6
6

Contact factory for other dimensions,


temperatures, and loads.
Available in all insulation thicknesses.

Copper
Tubing
Size O.D.
5/8 -1 5/8
2 1/8
2 5/8 - 4 1/8
5 1/8
6 1/8
8 1/8 -10 1/8
12 1/8

Application:

Features:

Material Data:

Model A3000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

A3000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces
Pipe rolls
Band, ring or clevis pipe hanger
Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A3000U)

24

MAXIMUM LOAD
RATING (LBS)
On Flat
On Pipe
In Ring
Surface
Roll
or Clevis
Hanger
(c) (d)
(a) (d)
(b) (d)
40
35
45
45
40
50
65
60
70
80
70
90
110
100
120
140
125
155
165
150
220
200
180
275
250
225
325
300
270
375
400
475
450
575
500
800
See
525
1100
575
1300
600
1500
625
1700
A5000
650
1900
700
2100
775
2400
TABLE I

Insulation Thickness
1 1/2
2
2 1/2
3
3 1/2
4
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
24
4
24
4
24
4
24
4
24
6
24
6
24
6
24
24
6
24
6
24
6
24
6
24
6
24
6
24
6
24
20
6
20
6
20
6
20
6
20
9
20
9
20
9
20
6
20
6
20
6
20
6
20
9
20
9
20
9
20
6
20
6
20
6
20
6
20
9
16
9
16
9
16
9
16
9
16
9
16
9
16
9
16
9
16
12 16 12 16 12 16 12 16 12 16 12 16
18 16 18 16 18 16 18 16 18 16 18 16
"B" = gauge of sheet metal jacket (bottom jac ket approx. 2 X ga. of top jacket)

3/4

TABLE II

1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24

Extra Heavy
Bottom Jacket

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket

Insulation: Calcium silicate asbestosfree, treated with water repellant

Minimizes heat loss and/or condensation

Jackets: Galvanized Steel ASTM A-653

Double thickness bottom jacket for added structural

Glue: Industrial contact adhesive

strength and abrasive wear resistance


Copper tubing sizes available
Other I.D.s and/or O.D.s available on request

Formal submittal sheets available

Clamps available (see G-series)


Clevis available (see PTP fig. 83)
Performance test results on file:
Available upon request.

www.pipeshields.com/a3000

A1000, A3000, A9000

A2000, A4000

Model A4000 Insulated Pipe Support

Pipe
Shields
Inc.

Extra Heavy Bottom Jacket


with extended Insulation
1"
TYP

Pipe
Size
A
INCHES

Oper.
Temp.
o
F

Hardware sold separately


Note: For higher load ratings, see A6000, A9000.

Mult.
Factor
"F"

500
0.90
750
0.75
1000
0.50
1200
0.30
TABLE III

The load ratings represent average values obtained in accordance with accepted
methods and are subject to normal manufacturing variations. Dimensions and
ratings are subject to change without notice.
a) To develop maximum load rating, width of support surface should be at
least 1/2 of dimension A in Table II.
b) Divide A in Table II by 6 to find maximum allowable travel on pipe roll
(+/- from centered position).
c) To develop maximum load rating, use band, ring or clevis hanger with
manufacturers load rating equal to or greater than values shown in Table I.
d) To obtain load ratings for operating temperatures of 500F and higher,
multiply load rating by factor F in Table III.
Iron
Pipe
Size
1/2 - 1 1/2
2
2 1/2 - 4
5
6-7
8 - 10
12 - 18
20 - 24

A
6
6
6

1/2

B
24
24
20

A
6
6
6

Contact factory for other dimensions,


temperatures, and loads.
Available in all insulation thicknesses.

Insulation Thickness
1 1/2
2
2 1/2
3
3 1/2
4
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
24
6
24
6
24
6
24
6
24
6
24
6
24
6
24
24
6
24
6
24
6
24
6
24
6
24
6
24
6
24
20
6
20
6
20
6
20
6
20
9
20
9
20
9
20
6
20
6
20
6
20
6
20
9
20
9
20
9
20
6
20
6
20
6
20
6
20
9
16
9
16
9
16
9
16
9
16
9
16
9
16
9
16
9
16
12 16 12 16 12 16 12 16 12 16 12 16
18 16 18 16 18 16 18 16 18 16 18 16
"B" = gauge of sheet metal jacket (bottom jac ket approx. 2 X ga. of top jacket)

3/4

TABLE II

1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24

MAXIMUM LOAD
RATING (LBS)
On Flat
On Pipe
In Ring
Surface
Roll
or Clevis
Hanger
(c) (d)
(a) (d)
(b) (d)
40
35
45
45
40
50
65
60
70
80
70
90
110
100
120
140
125
155
165
150
220
200
180
275
250
225
325
300
270
375
400
475
450
575
500
800
See
525
1100
575
1300
600
1500
625
1700
A6000
650
1900
700
2100
775
2400
TABLE I

Application:

Features:

Model A4000 is designed for use on:


Cold water
Chilled water

Compact
Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Double thickness bottom jacket for added structural
strength and abrasive wear resistance
Minimizes heat loss and/or condensation
Calcium silicate insulation extends 1 beyond the
galvanized sheet metal jacket providing for an easier
vapor barrier joint with the pipe
Copper tubing sizes available

Intended for installation on:


Flat surfaces
Pipe rolls
Band, ring or clevis pipe hanger
Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A4000U)

www.pipeshields.com/a4000

Other I.D.s and/or O.D.s available on request


Clamps available (see G-series)

Copper
Tubing
Size O.D.
5/8-1 5/8
2 1/8
2 5/8 - 4 1/8
5 1/8
6 1/8
8 1/8 -10 1/8
12 1/8

Material Data:
A4000: Applicable PSI spec. doc.: No. 205
Insulation: Calcium silicate asbestosfree, treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Formal submittal sheets available

Clevis available (see PTP fig. 83)


Performance test results on file:
Available upon request.

25

Pipe
Shields
Inc.

Model A5000 Insulated Pipe Support

Pipe
Size
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42

A5000, A7000 - A8400


7000 - A8400

C THK.

B
A
INCHES

Oper.
Temp.
o
F

Mult.
Factor
"F"

MAXIMUM LOAD
RATING (LBS)
On Flat
Surface
(a) (b)

On Pipe
Roll
(b)

200
250
300
350
450
500
625
650
925
1000
1100
1200
1300
1400
1500
1500
1500

180
225
270
315
400
450
550
575
825
900
975
1075
1150
1250
1350
1350
1350

9
9
9
9
9
9
9
9
12
12
12
12
12
12
12
12
12
TABLE I

6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9

1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4

With load
distribution plate
Max. Axial
Travel
(inches)
on
Pipe Roll
+/2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3

Contact factory for other dimensions, temperatures, and loads. Available in


all insulation thicknesses.

500
0.90
750
0.75
1000
0.50
1200
0.30
TABLE II
Hardware sold separately
Note: For higher load ratings, see A7000

The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subject to change without notice. Contact fac tory for current information.
a) To develop maximum load rating, width of support surf ace should be at least 1/2 of dimension B in Table I.
b) To obtain load ratings for operating temperatures of 500 oF and higher, multiply maximum load rating by factor F in Table II.

Application:

Features:

Material Data:

Model A5000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Overlapping galvanized sheet metal jacket
Minimizes heat loss and/or condensation
Load distribution plate integral with bottom
jacket
Other I.D.s and/or O.D.s available on request

A5000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces
Pipe rolls
Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A5000U)

26

Performance test results on file:


Available upon request

Insulation: Calcium silicate asbestos-free,


treated with water repellant
Jackets: Galvanized steel ASTM A-653
Load distribution Plate: Carbon steel
ASTM A-36
Coating: Primer coated or hot-dip galvanized
Other coatings available upon request
Glue: Industrial contact adhesive
Formal submittal sheets available

www.pipeshields.com/a5000

Model A6000 Insulated Pipe Support

With load distribution plate


with exterior Insulation

Pipe
Size
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42

, A7000 A6000
- A8400

1"
TYP

C THK.

B
A
INCHES

Oper.
Temp.
o
F

Mult.
Factor
"F"

Pipe
Shields
Inc.

MAXIMUM LOAD
RATING (LBS)
On Flat
Surface
(a) (b)

On Pipe
Roll
(b)

200
250
300
350
450
500
625
650
925
1000
1100
1200
1300
1400
1500
1500
1500

180
225
270
315
400
450
550
575
825
900
975
1075
1150
1250
1350
1350
1350

9
9
9
9
9
9
9
9
12
12
12
12
12
12
12
12
12
TABLE I

6
6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9

1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4

Max. Axial
Travel
(inches)
on
Pipe Roll
+/2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3

Contact factory for other dimensions, temperatures, and loads. Available in


all insulation thicknesses.

500
0.90
750
0.75
1000
0.50
1200
0.30
TABLE II
Hardware sold separately
Note: For higher load ratings, see A7000

The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subject to change without notice. Contact fac tory for current information.
a) To develop maximum load rating, width of support surf ace should be at least 1/2 of dimension B in Table I.
b) To obtain load ratings for operating temperatures of 500 oF and higher, multiply maximum load rating by factor F in Table II.

Application:

Features:

Material Data:

Model A6000 is designed for use on:


Cold water
Chilled water

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Overlapping galvanized sheet metal jacket
Minimizes heat loss and/or condensation
Load distribution plate integral with bottom
jacket
Calcium silicate insulation extends 1 beyond
the galvanized sheet metal jacket providing
for an easier vapor barrier joint with the pipe
Other I.D.s and/or O.D.s available on request

A6000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces
Pipe rolls
Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A6000U)

Performance test results on file:

Insulation: Calcium Silicate asbestosfree, treated with water repellant


Jackets: Galvanized Steel ASTM A-653
Load distribution Plate: Carbon steel
ASTM A-36
Coating : Primer coated or hot-dip galvanized
Other coatings available upon request
Glue: Industrial contact adhesive
Formal submittal sheets available

Available upon request

www.pipeshields.com/a6000

27

Pipe
Shields
Inc.

Heavy Duty with


load bearing plate

Model A7000 Insulated Pipe Support

Pipe
Size

2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42

A5000, A7000 - A8400


A5000, A7000 - A8400

C THK.

B
A
INCHES

Note: For higher load ratings, see A7200

MAXIMUM
LOAD RTG.
(LBS)
On Flat
Surface
(a)
250
300
350
400
500
550
700
875
1600
1650
1850
2000
2100
2300
2500
2500
2500
TABLE I

6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9
9

3
3
3
3
3
3
3
6
6
6
6
6
6
6
6
6
6

1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4

Contact factory for other dimensions,


temperatures, and loads. Available in all
insulation thicknesses.

The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.
a) To develop maximum load rating, width of support sur face should be at least 1/2 of dimension B in Table I.

Application:

Features:

Material Data:

Model A7000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Minimizes heat loss and/or condensation

A7000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces
Pipe rolls, see A8000
Clevis hangers, see A9000

Insulating structural inserts for load transfer


Overlapping galvanized sheet metal jacket
Load distribution plate integral with bottom
jacket
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A7000U)

28

Insulation: Calcium silicate asbestosfree, treated with water repellant


Jackets: Galvanized steel ASTM A-653
Structural Inserts: High-density calcium
silicate asbestos-free, treated with water
repellant.
Load distribution Plate: Carbon steel
ASTM A-36

Performance test results on file:

Coating: Primer coated or hot-dip galvanized


Other coatings available upon request

Available upon request

Glue: Industrial contact adhesive


Formal submittal sheets available

www.pipeshields.com/a7000

Pipe
Shields
Inc.

Heavy Duty with


load bearing plate

Model A7200 Insulated Pipe Support

Pipe
Size
6
8
10
12
14
16
18
20
24
30
36
42

A5000, A7000 - A5000,


A8400 A7000 - A8400

C THK.

MAXIMUM
LOAD RTG.
(LBS)
On Flat
Surface
(a)
1000
1250
1550
2250
2780
3300
3600
3800
4100
4500
4500
4500
TABLE I

9
9
9
9
9
9
9
9
9
9
9
9

6
6
6
6
6
6
6
6
6
6
6
6

1/2
1/2
5/8
5/8
5/8
3/4
3/4
3/4
1
1
1
1

Contact factory for other dimensions,


temperatures, and loads. Available in all
insulation thicknesses.

A
INCHES

Note: For higher load ratings, see A7400, B1100


The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.
a) To develop maximum load rating, width of support sur face should be at least 1/2 of dimension B in Table I.

Application:

Features:

Material Data:

Model A7200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Minimizes heat-loss and/or condensation

A7200: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces
Pipe rolls, see A8200
Clevis hangers, see A9000

Insulating structural inserts for load transfer


Overlapping galvanized sheet metal jacket
Load distribution plate integral with bottom
jacket
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A7200U)

www.pipeshields.com/a7200

Insulation: Calcium silicate asbestosfree, treated with water repellant


Jackets: Galvanized steel ASTM A-653
Structural Inserts: High-density calcium
silicate asbestos-free, treated with water
repellant
Load distribution Plate: Carbon steel
ASTM A-36

Performance test results on file:

Coating: Primer coated or hot-dip galvanized


Other coatings available upon request

Available upon request

Glue: Industrial contact adhesive


Formal Submittal Sheets available

29

Pipe
Shields
Inc.

Model A7400 Insulated Pipe Support

Pipe
Size
10
12
14
16
18
20
24
30
36
42

A5000, A7000 - A8400


, A7000 - A8400

Heavy Duty with


load bearing plate

MAXIMUM
LOAD RTG.
(LBS)
On Flat
Surface
(a)
2100
3400
3900
4400
4800
5100
5500
5500
6500
7500

9
9
9
9
9
9
9
9
9
9

6
6
6
6
6
6
6
6
6
6

3/4
3/4
3/4
1
1
1
1
1
1
1

TABLE I
Contact factory for other dimensions,
temperatures, and loads. Available in all
insulation thicknesses.
C THK.

B
A
INCHES

Note: For higher load ratings, see B1200


The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.
a) To develop maximum load rating, width of support sur face should be at least 1/2 of dimension B in Table I.

Application:

Features:

Material Data:

Model A7400 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Minimizes heat-loss and/or condensation

A7400: Applicable PSI spec. doc.: No. 205.

Intended for installation on:


Flat surfaces
Pipe rolls, see A8400
Clevis hangers, see A9000

Insulating structural inserts for load transfer


Overlapping galvanized sheet metal jacket
Load distribution plate integral with bottom
jacket
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A7400U)

30

Insulation: Calcium Silicate asbestosfree, treated with water repellant


Jackets: Galvanized Steel ASTM A-653
Structural Inserts: High-density calcium
silicate asbestos-free, treated with water
repellant.
Load distribution Plate: Carbon steel
ASTM A-36

Performance Test Results on File:

Coating: Primer coated or hot-dip galvanized


Other coatings available upon request

Available upon request

Glue: Industrial contact adhesive


Formal Submittal Sheets available

www.pipeshields.com/a7400

Model A8000 Insulated Pipe Support

Pipe
Shields
Inc.

Heavy Duty with


load bearing plate

Pipe
Size
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24
30
36
42

A5000, A7000 - A8400

000 - A8400

C THK.

B
A
INCHES

MAXIMUM
LOAD RTG.
(LBS)
On
Pipe
Roll
225
250
300
350
450
500
625
875
1400
1475
1650
1800
1875
2050
2250
2250
2250

Max. Axial
Travel
(Inches)
on
Pipe Roll

9
9
9
9
9
9
9
12
12
12
12
12
12
12
12
12
12
TABLE I

6
6
6
6
6
6
6
9
9
9
9
9
9
9
9
9
9

1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4

2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4

Contact factory for other dimensions, temperatures, and


loads. Available in all insulation thicknesses.

Hardware sold separately


Note: For higher load ratings, see A8200
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.

Application:

Features:

Material Data:

Model A8000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Minimizes heat loss and/or condensation

A8000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Flat surfaces, see A7000
Pipe rolls
Clevis hangers, see A9000

Insulating structural inserts for load transfer


Overlapping galvanized sheet metal jacket
Load distribution plate integral with bottom
jacket
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A8000U)

www.pipeshields.com/a8000

Insulation: Calcium silicate asbestosfree, treated with water repellant


Jackets: Galvanized steel ASTM A-653
Structural Inserts: High-density calcium
silicate asbestos-free, treated with water
repellant
Load distribution Plate: Carbon steel
ASTM A-36

Performance test results on file:

Coating: Primer coated or hot-dip galvanized.


Other coatings available upon request

Available upon request

Glue: Industrial contact adhesive


Formal submittal sheets available

31

Pipe
Shields
Inc.

Model A8200 Insulated Pipe Support

Pipe
Size
6
8
10
12
14
16
18
20
24
30
36
42

000 - A8400
A5000, A7000 - A8400

MAXIMUM
LOAD RTG.
(LBS)
On
Pipe
Roll
900
1125
1375
2550
2650
2950
3200
3375
3675
4050
4050
4050

Heavy Duty with


load bearing plate

Max. Axial
Travel
(Inches)
on
Pipe Roll

12
12
12
12
12
12
12
12
12
12
12
12
TABLE I

9
9
9
9
9
9
9
9
9
9
9
9

1/2
1/2
5/8
5/8
5/8
3/4
3/4
3/4
1
1
1
1

3
3
3
3
3
3
3
3
3
3
3
3

C THK.

Contact factory for other dimensions, temperatures, and


loads. Available in all insulation thicknesses.

B
A
INCHES

Hardware sold separately


Note: For higher load ratings, see A8400, B1100
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.

Application:

Features:

Material Data:

Model A8200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Minimizes heat loss and/or condensation

A8200: Applicable PSI spec. doc.: No. 205.

Intended for installation on:


Pipe rolls
Flat surfaces, see A7200
Clevis hangers, see A9000

Insulating structural inserts for load transfer


Overlapping galvanized sheet metal jacket
Load distribution plate integral with bottom
jacket
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A8200U)

32

Insulation: Calcium silicate asbestosfree, treated with water repellant


Jackets: Galvanized steel ASTM A-653
Structural Inserts: High-density calcium
silicate asbestos-free, treated with water
repellant
Load distribution Plate: Carbon steel
ASTM A-36

Performance test results on file:

Coating: Primer coated or hot-dip galvanized


Other coatings available upon request

Available upon request

Glue: Industrial contact adhesive


Formal submittal sheets available

www.pipeshields.com/a8200

Model A8400 Insulated Pipe Support

Pipe
Shields
Inc.

Heavy Duty with


load bearing plate

Pipe
Size
10
12
14
16
18
20
24
30
36
42

, A7000 -A5000,
A8400 A7000 - A8400

MAXIMUM
LOAD RTG.
(LBS)
On
Pipe
Roll
1875
3400
3500
3950
4300
4550
4950
5450
6450
7450

Max. Axial
Travel
(Inches)
on
Pipe Roll

12
12
12
12
12
12
12
12
12
12
TABLE I

9
9
9
9
9
9
9
9
9
9

1
1
1
1
1
1
1
1
1
1

2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4
2 1/4

Contact factory for other dimensions, temperatures, and


loads. Available in all insulation thicknesses.

C THK.

B
A
INCHES

Hardware sold separately


Note: For higher load ratings, see B1200
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing
variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.

Application:

Features:

Material Data:

Model A8400 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Copper tubing sizes available
Minimizes heat loss and/or condensation

A8400: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Pipe rolls
Flat surfaces, see A7400
Clevis hangers, see A9000

Insulating structural inserts for load transfer


Overlapping galvanized sheet metal jacket
Load distribution plate integral with bottom
jacket
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A8400U)

www.pipeshields.com/a8400

Insulation: Calcium silicate asbestosfree, treated with water repellant


Jackets: Galvanized steel ASTM A-653
Structural Inserts: High-density calcium
silicate asbestos-free, treated with water
repellant
Load distribution Plate: Carbon steel
ASTM A-36

Performance test results on file:

Coating: Primer coated or hot-dip galvanized


Other coatings available upon request

Available upon request

Glue: Industrial contact adhesive


Formal submittal sheets available

33

Pipe
Shields
Inc.

Heavy Duty for use


with rod hangers

Model A9000 Insulated Pipe Support


A1000, A3000, A9000

MAXIMUM
LOAD RTG.
(LBS)
In Ring
or Clevis
Hanger
(a)

A1000, A3000, A9000

Pipe
Size

A
INCHES

Hardware sold separately


Note: For higher load ratings, see D1000, D3000
The load ratings represent average values obtained in accordance with accepted methods and are subject
to normal manufacturing variations. Dim ensions and ratings are subject to change without notice.
a) To develop maximum load rating use band, ring or clevis hanger with manufacturers load rating
equal to or greater than values shown in Table I.

1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
14
16
18
20
24

TABLE I

50
55
80
100
130
175
250
300
350
400
550
600
900
1200
1450
1650
1900
2150
2400
2750

Contact factory for other dimensions,


temperatures, and loads. Available in all
insulation thicknesses.
Iron
Pipe
Size
1/2 - 1 1/2
2
2 1/2 - 4
5
6-7
8 - 10
12 - 18
20 - 24

A
4
6
6

1/2

B
24
24
20

A
4
6
6

3/4

B
24
24
20

TABLE II

Insulation Thickness
1 1/2
2
2 1/2
3
A
B
A
B
A
B
A
B
A
4
24
4
24
4
24
4
24
6
6
24
6
24
6
24
6
24
6
6
20
6
20
6
20
6
20
9
6
20
6
20
6
20
6
20
9
6
20
6
20
6
20
6
20
9
9
16
9
16
9
16
9
12
16
12
16
12
16
12
18
16
18
16
18
16
18
"B" = gauge of sheet metal jacket (bottom jac ket approx. 2

3 1/2
B
A
B
24
6
24
24
6
24
20
9
20
20
9
20
16
9
16
16
9
16
16
12
16
16
18
16
X ga. of top jacket)

A
6
6
9
9
9
9
12
18

B
24
24
20
20
16
16
16
16

Copper
Tubing
Size O.D.
5/8-1 5/8
2 1/8
2 5/8 - 4 1/8
5 1/8
6 1/8
8 1/8 -10 1/8
12 1/8

Application:

Features:

Material Data:

Model A9000 is designed for use on:


Hot water
Steam
Cold wwater
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact
Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal
jacket
Minimizes heat loss and/or condensation
Insulating structural inserts for load transfer
Copper tubing available
Other I.D.s and/or O.D.s available on
request

A9000: Applicable PSI spec. doc.: No. 205

Intended for installation on:


Band, ring or clevis pipe hangers
Flat surfaces, see A7000
Pipe rolls, see A8000
Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., A9000U)

34

Insulation: Calcium silicate asbestosfree, treated with water repellant


Jackets: Galvanized steel ASTM A-653
Structural Inserts: High-density calcium
silicate asbestos-free, treated with water
repellant
Glue: Industrial contact adhesive
Formal submittal sheets available

Performance test results on file:


Available upon request

www.pipeshields.com/a9000

Pipe
Shields
Inc.

35

Pipe
Shields
Inc.

Introduction: Section B

INTRODUCTION
SECTION B
PRE-INSULATED PIPE SUPPORTS - Base Mounted
APPLICATION Heavy Industrial and Large HVAC Distribution Systems
Features:
Accommodation of thermal movement
Provision or lateral guide or restraint
Minimization of side friction loads
Wide range of maximum load requirements for each pipe size
Note: In each model number series (for example: B1000 through B1300 Series), the higher the
model number, the higher the load rating.
Models B1000 - B1300

Sliding supports free to travel axially and laterally.

Models B2000 - B2300

Same as B1000 - B1300 except can accommodate greater axial travel.

Models B3000 - B3300

Sliding supports with lateral guides.

Models B4000 - B4300

Same as B3000 - B3300 except can accommodate greater axial travel.

Models B5000 - B5300

Same as B1000 - B1300 except can accommodate greater lateral travel.

Models B6000 - B6300

Same as B2000 - B2300 except can accommodate greater lateral travel.

Models B7000 - B7300

Same as B3000 - B3300 except with reduced vertical load ratings to allow greater
lateral loads. Minimum side friction is assured by the addition of lateral slide pads.

Models B8000 - B8300

Same as B4000 - B4300 except with reduced vertical load ratings to allow greater
lateral loads. Minimum side friction is assured by the addition of lateral slide pads.

To meet special thermal movement requirements, Pipe Shields, Inc. has provided supports that have
accommodated axial travels in excess of five (5) feet. By modifying our standard pipe support concept
with combinations of structural insulation materials, steel base and strap design, and slide plate
configuration, we can readily and economically respond to virtually any pipe support requirement.
If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at
707-447-5014 or 1-800-538-7007.

Please acquaint yourself with the selection guide at the front of this catalog and the section index
on the page following this introduction, for assistance in determining the most appropriate support
for your application.

36

Pipe
Shields
Inc.

Section B Index
PRE-INSULATED PIPE SUPPORTS

HEAVY INDUSTRIAL - BASE MOUNTED


B1000

B2000

B3000

B4000

TRAVEL
(INCHES) +/AXIAL
LATERAL

MODEL

PIPE
SIZE
RANGE

B1000
B1100
B1200
B1300

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

1.5
1.5
1.5
1.5

B2000
B2100
B2200
B2300

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

B3000
B3100
B3200
B3300

B4000
B4100
B4200
B4300

www.pipeshields.com/b-series

LATERAL
GUIDE

DUTY

1.5
1.5
1.5
1.5

NO
NO
NO
NO

MEDIUM
HEAVY
HEAVIER
HEAVIEST

4.5
4.5
4.5
4.5

1.5
1.5
1.5
1.5

NO
NO
NO
NO

MEDIUM
HEAVY
HEAVIER
HEAVIEST

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

1.5
1.5
1.5
1.5

0
0
0
0

YES
YES
YES
YES

MEDIUM
HEAVY
HEAVIER
HEAVIEST

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

4.5
4.5
4.5
4.5

0
0
0
0

YES
YES
YES
YES

MEDIUM
HEAVY
HEAVIER
HEAVIEST

37

Pipe
Shields
Inc.

Section B Index
PRE-INSULATED PIPE SUPPORTS

HEAVY INDUSTRIAL - BASE MOUNTED


B5000

B6000

B7000

B8000

38

TRAVEL
(INCHES) +/AXIAL
LATERAL

MODEL

PIPE
SIZE
RANGE

B5000
B5100
B5200
B5300

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

1.5
1.5
1.5
1.5

B6000
B6100
B6200
B6300

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

B7000
B7100
B7200
B7300

B8000
B8100
B8200
B8300

LATERAL
GUIDE

DUTY

1.5 - 4.5
1.5 - 4.5
1.5 - 4.5
1.5 - 4.5

NO
NO
NO
NO

MEDIUM
HEAVY
HEAVIER
HEAVIEST

4.5
4.5
4.5
4.5

1.5 - 4.5
1.5 - 4.5
1.5 - 4.5
1.5 - 4.5

NO
NO
NO
NO

MEDIUM
HEAVY
HEAVIER
HEAVIEST

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

1.5
1.5
1.5
1.5

0
0
0
0

YES
YES
YES
YES

MEDIUM
HEAVY
HEAVIER
HEAVIEST

1/2 - 42
1/2 - 42
1/2 - 42
1/2 - 42

4.5
4.5
4.5
4.5

0
0
0
0

YES
YES
YES
YES

MEDIUM
HEAVY
HEAVIER
HEAVIEST

www,pipeshields.com/b-series

Pipe
Shields
Inc.

Section B Index

THE FOLLOWING TABLE ILLUSTRATES


BOTTOM-O F-PIPE TO TOP-OF-STEEL DIMENSIONS
(DIMENSION B) FOR B MODEL PIPE SUPPORTS AND C M ODEL PIPE ANCHORS FOR
INTERMEDIATE INSULATION THICKNESS
INSULATION THICKNESS

PIPE
SIZE

3 1/2

4 1/2

5 1/2

6 1/2

7 1/2

8 1/2

9 1/2

10

10

12

12

12

12

13

14

3 1/2

10

12

12

12

12

13

14

10

12

12

12

12

13

14

10

12

12

12

12

13

14

10

12

12

12

12

13

14

10

10

12

12

12

12

13

14

10

10

10

12

12

12

12

13

14

12

10

10

12

12

12

12

13

14

14

10

10

12

12

12

12

13

14

16

10

10

10

12

12

12

12

13

14

18

10

10

10

12

12

12

12

13

14

20

10

10

10

12

12

12

12

13

14

24

10

10

10

12

12

12

12

13

14

30

10

10

10

10

12

12

12

12

13

14

36

10

10

10

10

12

12

12

12

13

14

42

10

10

10

10

12

12

12

12

13

14

COMMENTS:
The insulation thickness shown on the Product Data Sheets in Sections B and C are in
even 1 increments. The table shown here provides Bottom-of-Pipe to Top-of-Steel dimensions
(B Dimensions) for 3 1/2, 4 1/2, 5 1/2, 6, 6 1/2, 7, 7 1/2, 8, 8 1/2, 9, 9 1/2, and 10 insulation
thicknesses. Check with factory if you require a B dimension other than those shown in this table.

TO ORDER, specify:
1. Quantity 20
2. Pipe Size & Type
18 IPS
3. Insulation Thickness
2
4. Model Number
B1000
EXAMPLE: (20) 18

www.pipeshields.com/b-series

B1000

39

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B1000 Sliding Insulated Pipe Support


B1000
1/2" MAX.

B5000LATERAL TRAVEL
E

"L" MAX.
LATERAL TRAVEL

9"
9"

PIPE
B.O.P.
B

T.O.S.

1 1/2" MAX.
AXIAL TRAVEL

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

6"

3"

6"

STEEL MOUNTING PLATE

STEEL MOUNTING PLATE

POLYETHYLENE SLIDE PAD

POLYETHYLENE SLIDE PAD


3"

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions
and ratings are subject to change without notice.
Note: For higher load ratings, see: B1100 - For greater axial travel, see: B2000 - For lateral restraint, see: B3000 - For lateral travel, see: B5000.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
140
175
225
325
375
460
530
840
1050
1275
1700
2000
2200
2500
2900
3200
3400
3600
4700
5500
6200

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.25
1.5
3.25
2
3.875
2
4.375
2.5
5
2.5
5.5
3
6.062
4
7.25
4.5
8.25
5.5
9.25
7.5
11.625
9
13.625
10.5
16.125
11
17.125
12.5
19.125
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
39.625
31
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
2
4.375
4
2
4.375
4
2.5
4.875
4
2.5
5.5
4
3
6.0625
4
4
7.125
4
4
7.125
4
4.5
8.25
4
5.5
9.25
4
6.5
10.25
4
8
12.625
4
9.5
14.875
4
11
17.125
4
12
18.125
4
13
20.125
4
14.5
22.375
4
16
24.375
4
19
28.375
6
23
34.625
6
27.5
41.125
6
31.5
47.125

Insul. Thk. = 2"


C
E
2.5
5.375
2.5
5.375
3
5.937
4
7
4
7
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.25
7.5
11.375
9
13.625
10.5
15.875
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
4
7
4
4
7
4
4
7
4
4.5
8
4
4.5
8
4
5.5
9.125
4
5.5
9.125
4
6.5
10.25
4
7.5
11.375
4
8
12.625
6
9.5
14.875
6
11
16.875
6
12.5
19.125
6
13
20.125
6
14.5
22.375
6
16
24.375
6
17.5
26.375
6
20.5
30.375
6
24.5
36.625
6
28.5
43.125
6
33
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8
4.5
8
4.5
8
5.5
9
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.375
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
6.5
10
6.5
10
6.5
10
7.5
11.25
7.5
11.25
8
12.25
8
12.375
9
13.375
9.5
14.875
10.5
15.875
12
17.875
13
20.125
14.5
22.125
15.5
23.125
16.5
25.375
18
27.375
19.5
29.375
22.5
33.375
26.5
39.625
31
46.125
35
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
8
12.125
8
12.125
8
12.25
9
13.25
9
13.25
9.5
14.5
9.5
14.625
10.5
15.625
11
16.875
12
17.875
13
20.125
14.5
22.125
16
24.125
16.5
25.125
18
27.375
19.5
29.375
21
31.375
24
35.375
28
41.625
32.5
48.125
36.5
54.125

Application:

Features:

Material Data:

Model B1000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B1000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B1000U)

40

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request

Formal Submittal Sheets available

www,pipingtech.com/b1000

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B1100 Sliding Insulated Pipe Support


B1000

1/2" MAX.

B5000LATERAL TRAVEL
E

"L" MAX.
LATERAL TRAVEL

9"
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

PIPE

B.O.P.

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.

T.O.S.

T.O.S.
3"

6"

3"

6"

STEEL MOUNTING PLATE

STEEL MOUNTING PLATE

POLYETHYLENE SLIDE PAD

POLYETHYLENE SLIDE PAD


3"

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B1200 - For greater axial travel, see: B2100 - For lateral restraint, see: B3100 - For lateral travel, see: B5100.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
280
350
450
650
750
920
1060
1680
2100
2550
3400
4000
4400
5000
5800
6400
6800
7200
9400
11000
12400

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.25
1.5
3.25
2
3.875
2
4.5
2.5
5
2.5
5.5
3
6.187
4
7.25
4.5
8.5
5.5
9.5
7.5
11.625
9
13.875
10.5
16.125
11
17.125
12.5
19.375
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
40.125
31
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
2
4.375
4
2
4.375
4
2.5
5
4
2.5
5.5
4
3
6.0625
4
4
7.125
4
4
7.125
4
4.5
8.25
4
5.5
9.5
4
6.5
10.5
4
8
12.625
4
9.5
15.125
4
11
17.125
4
12
18.125
4
13
20.375
4
14.5
22.375
4
16
24.375
4
19
28.375
6
23
34.625
6
27.5
41.125
6
31.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
2.5
5.375
2.5
5.375
3
6.062
4
7.125
4
7.125
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.5
7.5
11.625
9
13.625
10.5
16.125
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
4
7
4
4
7
4
4
7
4
4.5
8.125
4
4.5
8.125
4
5.5
9.125
4
5.5
9.125
4
6.5
10.25
4
7.5
11.625
4
8
12.625
6
9.5
14.875
6
11
17.125
6
12.5
19.125
6
13
20.125
6
14.5
22.375
6
16
24.375
6
17.5
26.375
6
20.5
30.375
6
24.5
36.625
6
28.5
43.125
6
33
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8
4.5
8
4.5
8
5.5
9.125
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.625
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
6.5
10
6.5
10
6.5
10
7.5
11.25
7.5
11.25
8
12.25
8
12.375
9
13.375
9.5
14.875
10.5
15.875
12
18.125
13
20.125
14.5
22.125
15.5
23.125
16.5
25.375
18
27.375
19.5
29.375
22.5
33.375
26.5
39.625
31
46.125
35
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
8
12.125
8
12.25
8
12.25
9
13.25
9
13.25
9.5
14.5
9.5
14.625
10.5
15.625
11
16.875
12
17.875
13
20.125
14.5
22.125
16
24.125
16.5
25.125
18
27.375
19.5
29.375
21
31.375
24
35.375
28
41.625
32.5
48.125
36.5
54.125

Application:

Features:

Material Data:

Model B1100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B1100: Applicable PSI spec. doc.: No. 209.


Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant.
Steel Straps/Base: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (PTFE optional).
Coating: Primer coated or hot dipped galvanized.

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B1100U)

www.pipeshields.com/b1100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request.

Available upon request.

Formal submittal sheets available

41

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B1200 Sliding Insulated Pipe Support


B1000
B5000

1/2" MAX.
LATERAL TRAVEL

"L" MAX.
LATERAL TRAVEL
9"

9"

PIPE

PIPE

1 1/2" MAX.
1 1/2" MAX.
AXIAL TRAVEL AXIAL TRAVEL

B.O.P.

B.O.P.
B

T.O.S.

T.O.S.

3"

6"

3"
C

STEEL MOUNTING PLATE

6"

POLYETHYLENE
STEEL
MOUNTING SLIDE
PLATEPAD

POLYETHYLENE SLIDE PAD


3"

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B1300 - For greater axial travel, see: B2200 - For lateral restraint, see: B3200 - For lateral travel, see: B5200.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
400
500
650
950
1100
1350
1600
2500
3100
3800
5100
6000
6600
7500
8700
9600
10200
10800
14100
16500
18600

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.25
1.5
3.25
2
4
2
4.5
2.5
5
2.5
5.5
3
6.187
4
7.25
4.5
8.5
5.5
9.5
7.5
11.625
9
13.875
10.5
16.125
11
17.125
12.5
19.375
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
40.125
31
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
2
4.375
4
2
4.375
4
2.5
5
4
2.5
5.5
4
3
6.1875
4
4
7.125
4
4
7.125
4
4.5
8.25
4
5.5
9.5
4
6.5
10.5
4
8
12.625
4
9.5
15.125
4
11
17.125
4
12
18.125
4
13
20.375
4
14.5
22.375
4
16
24.375
4
19
28.375
6
23
34.625
6
27.5
41.125
6
31.5
47.125

Insul. Thk. = 2"


C
E
2.5
5.375
2.5
5.375
3
6.062
4
7.125
4
7.125
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.5
7.5
11.625
9
13.625
10.5
16.125
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
4
7
4
4
7
4
4
7.125
4
4.5
8.125
4
4.5
8.125
4
5.5
9.125
4
5.5
9.125
4
6.5
10.25
4
7.5
11.625
4
8
12.625
6
9.5
14.875
6
11
17.125
6
12.5
19.125
6
13
20.125
6
14.5
22.375
6
16
24.375
6
17.5
26.375
6
20.5
30.375
6
24.5
36.625
6
28.5
43.125
6
33
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8
4.5
8
4.5
8.125
5.5
9.125
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.625
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
6.5
10
6.5
10
6.5
10.125
7.5
11.25
7.5
11.25
8
12.25
8
12.375
9
13.375
9.5
14.875
10.5
15.875
12
18.125
13
20.125
14.5
22.125
15.5
23.125
16.5
25.375
18
27.375
19.5
29.375
22.5
33.375
26.5
39.625
31
46.125
35
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
8
12.125
8
12.25
8
12.25
9
13.25
9
13.25
9.5
14.5
9.5
14.625
10.5
15.625
11
16.875
12
17.875
13
20.125
14.5
22.125
16
24.125
16.5
25.125
18
27.375
19.5
29.375
21
31.375
24
35.375
28
41.625
32.5
48.125
36.5
54.125

Application:

Features:

Material Data:

Model B1200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B1200: Applicable PSI spec. doc.: No. 209.


Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant.
Steel Straps/Base: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Slide Pad: UHMW Polyethylene (PTFE optional).
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B1200U)

42

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on sile:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

www.pipeshields.com/b1200

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B1300 Sliding Insulated Pipe Support


B1000

1/2" MAX.

B5000 LATERAL TRAVEL


E

"L" MAX.
LATERAL TRAVEL

9"
9"

PIPE
B.O.P.
B

T.O.S.

1 1/2" MAX.
AXIAL TRAVEL 1 1/2" MAX.

PIPE

AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

6"

3"

6"

STEEL MOUNTING PLATE

STEEL MOUNTING PLATE

POLYETHYLENE SLIDE PAD

POLYETHYLENE SLIDE PAD


3"

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings contact factory - For greater axial travel, see: B2300 - For lateral restraint, see: B3300 - For lateral travel, see: B5300.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.375
1.5
3.375
2
4
2
4.5
2.5
5
2.5
5.5
3
6.187
4
7.25
4.5
8.5
5.5
9.5
7.5
11.625
9
13.875
10.5
16.125
11
17.125
12.5
19.375
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
40.125
31
46.125

Insul.
B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

Thk. =
C
2
2
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5

1-1/2"
E
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
2.5
5.5
2.5
5.5
3
6.062
4
7.125
4
7.125
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.5
7.5
11.625
9
13.625
10.5
16.125
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul.
B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

Thk. =
C
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33

2-1/2"
E
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8.125
4.5
8.125
4.5
8.125
5.5
9.125
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.625
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk.
C
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35

=4"

E
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
8
12.25
8
12.25
8
12.25
9
13.25
9
13.25
9.5
14.625
9.5
14.625
10.5
15.625
11
16.875
12
17.875
13
20.125
14.5
22.125
16
24.125
16.5
25.125
18
27.375
19.5
29.375
21
31.375
24
35.375
28
41.625
32.5
48.125
36.5
54.125

Application:

Features:

Material Data:

Model B1300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B1300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium Silicate asbestos-free,
treated with water repellant
Jackets: Galvanized Steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B1300U)

www.pipeshields.com/b1300

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request

Formal submittal sheets available

43

Pipe
Shields
Inc.

Model
B2000

Heavy Duty,
Base Mounted

B2000 Sliding Insulated Pipe Support


B5000
1/2" MAX.
LATERAL TRAVEL

"L" MAX.
LATERAL TRAVEL
9"

15"

PIPE

PIPE
B.O.P.

1 1/2" MAX.
AXIAL TRAVEL

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
B

3"

T.O.S.

3"

6"

STEEL MOUNTING PLATE

12"

POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B2100 - For lesser axial travel, see: B1000 - For lateral restraint, see: B4000 - For lateral travel, see: B6000.

Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
140
175
225
325
375
460
530
840
1050
1275
1700
2000
2200
2500
2900
3200
3400
3600
4700
5500
6200

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.25
1.5
3.25
2
3.875
2
4.375
2.5
5
2.5
5.5
3
6.062
4
7.25
4.5
8.25
5.5
9.25
7.5
11.625
9
13.625
10.5
16.125
11
17.125
12.5
19.125
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
39.625
31
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
2
4.375
4
2
4.375
4
2.5
4.875
4
2.5
5.5
4
3
6.0625
4
4
7.125
4
4
7.125
4
4.5
8.25
4
5.5
9.25
4
6.5
10.25
4
8
12.625
4
9.5
14.875
4
11
17.125
4
12
18.125
4
13
20.125
4
14.5
22.375
4
16
24.375
4
19
28.375
6
23
34.625
6
27.5
41.125
6
31.5
47.125

Insul. Thk. = 2"


C
E
2.5
5.375
2.5
5.375
3
5.937
4
7
4
7
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.25
7.5
11.375
9
13.625
10.5
15.875
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
4
7
4
4
7
4
4
7
4
4.5
8
4
4.5
8
4
5.5
9.125
4
5.5
9.125
4
6.5
10.25
4
7.5
11.375
4
8
12.625
6
9.5
14.875
6
11
16.875
6
12.5
19.125
6
13
20.125
6
14.5
22.375
6
16
24.375
6
17.5
26.375
6
20.5
30.375
6
24.5
36.625
6
28.5
43.125
6
33
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8
4.5
8
4.5
8
5.5
9
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.375
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
6.5
10
6.5
10
6.5
10
7.5
11.25
7.5
11.25
8
12.25
8
12.375
9
13.375
9.5
14.875
10.5
15.875
12
17.875
13
20.125
14.5
22.125
15.5
23.125
16.5
25.375
18
27.375
19.5
29.375
22.5
33.375
26.5
39.625
31
46.125
35
52.125

Insul. Thk. = 5"


B
C
E
8
8
12.125
8
8
12.125
8
8
12.25
8
9
13.25
8
9
13.25
8
9.5
14.5
8
9.5
14.625
8
10.5
15.625
8
11
16.875
8
12
17.875
8
13
20.125
8
14.5
22.125
8
16
24.125
8
16.5
25.125
8
18
27.375
8
19.5
29.375
8
21
31.375
8
24
35.375
8
28
41.625
8
32.5
48.125
8
36.5
54.125

Application:

Features:

Material Data:

Model B2000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B2000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B2000U)

44

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request

Formal submittal sheets available

www.pipeshields.com/b2000

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

B2000
Model B2100 Sliding Insulated Pipe
Support
B5000

1/2" MAX.
LATERAL TRAVEL

"L" MAX.
LATERAL TRAVEL
9"

15"

PIPE

PIPE
B.O.P.

1 1/2" MAX.
AXIAL TRAVEL

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
B
3"

T.O.S.

3"

6"

STEEL MOUNTING PLATE

12"

POLYETHYLENE SLIDE PAD

STEEL MOUNTING PLATE

3"

POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B2200 - For lesser axial travel, see: B1100 - For lateral restraint, see: B4100 - For lateral travel, see: B6100.

Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
280
350
450
650
750
920
1060
1680
2100
2550
3400
4000
4400
5000
5800
6400
6800
7200
9400
11000
12400

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.25
1.5
3.25
2
3.875
2
4.5
2.5
5
2.5
5.5
3
6.187
4
7.25
4.5
8.5
5.5
9.5
7.5
11.625
9
13.875
10.5
16.125
11
17.125
12.5
19.375
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
40.125
31
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
2
4.375
4
2
4.375
4
2.5
5
4
2.5
5.5
4
3
6.0625
4
4
7.125
4
4
7.125
4
4.5
8.25
4
5.5
9.5
4
6.5
10.5
4
8
12.625
4
9.5
15.125
4
11
17.125
4
12
18.125
4
13
20.375
4
14.5
22.375
4
16
24.375
4
19
28.375
6
23
34.625
6
27.5
41.125
6
31.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
2.5
5.375
2.5
5.375
3
6.062
4
7.125
4
7.125
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.5
7.5
11.625
9
13.625
10.5
16.125
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
4
7
4
4
7
4
4
7
4
4.5
8.125
4
4.5
8.125
4
5.5
9.125
4
5.5
9.125
4
6.5
10.25
4
7.5
11.625
4
8
12.625
6
9.5
14.875
6
11
17.125
6
12.5
19.125
6
13
20.125
6
14.5
22.375
6
16
24.375
6
17.5
26.375
6
20.5
30.375
6
24.5
36.625
6
28.5
43.125
6
33
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8
4.5
8
4.5
8
5.5
9.125
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.625
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
6.5
10
6.5
10
6.5
10
7.5
11.25
7.5
11.25
8
12.25
8
12.375
9
13.375
9.5
14.875
10.5
15.875
12
18.125
13
20.125
14.5
22.125
15.5
23.125
16.5
25.375
18
27.375
19.5
29.375
22.5
33.375
26.5
39.625
31
46.125
35
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
8
12.125
8
12.25
8
12.25
9
13.25
9
13.25
9.5
14.5
9.5
14.625
10.5
15.625
11
16.875
12
17.875
13
20.125
14.5
22.125
16
24.125
16.5
25.125
18
27.375
19.5
29.375
21
31.375
24
35.375
28
41.625
32.5
48.125
36.5
54.125

Application:

Features:

Material Data:

Model B2100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B2100: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B2100U)

www.pipeshields.com/b2100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

45

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model
B2000 B2200 Sliding Insulated Pipe Support
1/2" MAX.

B5000LATERAL TRAVEL
E

"L" MAX.
LATERAL TRAVEL

15"
9"

PIPE
B.O.P.
B

4 1/2" MAX.
1 1/2" MAX.
AXIAL TRAVEL

PIPE

AXIAL TRAVEL

B.O.P.
B

T.O.S.

T.O.S.
3"

3"

6"

12"

STEEL MOUNTING PLATE

STEEL MOUNTING PLATE

POLYETHYLENE SLIDE PAD

POLYETHYLENE SLIDE PAD


3"

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B2300 - For lesser axial travel, see: B1200 - For lateral restraint, see: B4200 - For lateral travel, see: B6200.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
400
500
650
950
1100
1350
1600
2500
3100
3800
5100
6000
6600
7500
8700
9600
10200
10800
14100
16500
18600

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.25
1.5
3.25
2
4
2
4.5
2.5
5
2.5
5.5
3
6.187
4
7.25
4.5
8.5
5.5
9.5
7.5
11.625
9
13.875
10.5
16.125
11
17.125
12.5
19.375
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
40.125
31
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
2
4.375
4
2
4.375
4
2.5
5
4
2.5
5.5
4
3
6.1875
4
4
7.125
4
4
7.125
4
4.5
8.25
4
5.5
9.5
4
6.5
10.5
4
8
12.625
4
9.5
15.125
4
11
17.125
4
12
18.125
4
13
20.375
4
14.5
22.375
4
16
24.375
4
19
28.375
6
23
34.625
6
27.5
41.125
6
31.5
47.125

Insul. Thk. = 2"


C
E
2.5
5.375
2.5
5.375
3
6.062
4
7.125
4
7.125
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.5
7.5
11.625
9
13.625
10.5
16.125
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
4
7
4
4
7
4
4
7.125
4
4.5
8.125
4
4.5
8.125
4
5.5
9.125
4
5.5
9.125
4
6.5
10.25
4
7.5
11.625
4
8
12.625
6
9.5
14.875
6
11
17.125
6
12.5
19.125
6
13
20.125
6
14.5
22.375
6
16
24.375
6
17.5
26.375
6
20.5
30.375
6
24.5
36.625
6
28.5
43.125
6
33
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8
4.5
8
4.5
8.125
5.5
9.125
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.625
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
6.5
10
6.5
10
6.5
10.125
7.5
11.25
7.5
11.25
8
12.25
8
12.375
9
13.375
9.5
14.875
10.5
15.875
12
18.125
13
20.125
14.5
22.125
15.5
23.125
16.5
25.375
18
27.375
19.5
29.375
22.5
33.375
26.5
39.625
31
46.125
35
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
8
12.125
8
12.25
8
12.25
9
13.25
9
13.25
9.5
14.5
9.5
14.625
10.5
15.625
11
16.875
12
17.875
13
20.125
14.5
22.125
16
24.125
16.5
25.125
18
27.375
19.5
29.375
21
31.375
24
35.375
28
41.625
32.5
48.125
36.5
54.125

Application:

Features:

Material Data:

Model B2200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B2200: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B2200U)

46

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

www.pipeshields.com/b2200

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B2300 Sliding Insulated Pipe


B2000 Support

1/2" MAX.
B5000LATERAL
TRAVEL
E

"L" MAX.
LATERAL TRAVEL

15"
9"

PIPE

4 1/2" MAX.
1 1/2" MAX.
AXIAL TRAVEL
AXIAL TRAVEL

PIPE

B.O.P.

B.O.P.
B

T.O.S.

T.O.S.
3"

3"

6"

12"

STEEL MOUNTING PLATE

STEEL
MOUNTINGSLIDE
PLATEPAD
POLYETHYLENE
POLYETHYLENE SLIDE PAD
3"

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - For lesser axial travel, see: B1300 - For lateral restraint, see: B4300 - For lateral travel, see: B6300.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
1.5
3.375
1.5
3.375
2
4
2
4.5
2.5
5
2.5
5.5
3
6.187
4
7.25
4.5
8.5
5.5
9.5
7.5
11.625
9
13.875
10.5
16.125
11
17.125
12.5
19.375
14
21.375
15.5
23.375
18
27.375
22.5
33.625
26.5
40.125
31
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
2
4.5
4
2
4.5
4
2.5
5
4
2.5
5.5
4
3
6.0625
4
4
7.125
4
4
7.125
4
4.5
8.25
4
5.5
9.5
4
6.5
10.5
4
8
12.625
4
9.5
15.125
4
11
17.125
4
12
18.125
4
13
20.375
4
14.5
22.375
4
16
24.375
4
19
28.375
6
23
34.625
6
27.5
41.125
6
31.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
2.5
5.5
2.5
5.5
3
6.062
4
7.125
4
7.125
4.5
8.125
4.5
8.125
5.5
9.25
6.5
10.5
7.5
11.625
9
13.625
10.5
16.125
12
18.125
12.5
19.125
14
21.375
15.5
23.375
16.5
25.375
19.5
29.375
24
35.625
28
42.125
32.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
4
7.125
4
4
7.125
4
4
7.125
4
4.5
8.125
4
4.5
8.125
4
5.5
9.125
4
5.5
9.125
4
6.5
10.25
4
7.5
11.625
4
8
12.625
6
9.5
14.875
6
11
17.125
6
12.5
19.125
6
13
20.125
6
14.5
22.375
6
16
24.375
6
17.5
26.375
6
20.5
30.375
6
24.5
36.625
6
28.5
43.125
6
33
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
4.5
8.125
4.5
8.125
4.5
8.125
5.5
9.125
5.5
9.125
6.5
10.125
6.5
10.125
7.5
11.375
8
12.625
9
13.625
10.5
15.875
12
18.125
13
20.125
14
21.125
15.5
23.375
16.5
25.375
18
27.375
21
31.375
25
37.625
29.5
44.125
33.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
6.5
10.125
6.5
10.125
6.5
10.125
7.5
11.25
7.5
11.25
8
12.375
8
12.375
9
13.375
9.5
14.875
10.5
15.875
12
18.125
13
20.125
14.5
22.125
15.5
23.125
16.5
25.375
18
27.375
19.5
29.375
22.5
33.375
26.5
39.625
31
46.125
35
52.125

Insul. Thk. = 5"


B
C
E
8
8
12.25
8
8
12.25
8
8
12.25
8
9
13.25
8
9
13.25
8
9.5
14.625
8
9.5
14.625
8
10.5
15.625
8
11
16.875
8
12
17.875
8
13
20.125
8
14.5
22.125
8
16
24.125
8
16.5
25.125
8
18
27.375
8
19.5
29.375
8
21
31.375
8
24
35.375
8
28
41.625
8
32.5
48.125
8
36.5
54.125

Application:

Features:

Material Data:

Model B2300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B2300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized Steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE Optional)
Coating: Primer coated or hot dipped galvanized.

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B2300U)

www.pipeshields.com/b2300

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

47

Pipe
Shields
Inc.

Model
B3000 B3000 Guided Insulated Pipe Support

Heavy Duty,
Base Mounted

9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

STEEL MOUNTING PLATE


WITH RESTRAINTS

1/8" CLR
TYP
C

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B3100 - For greater axial travel, see: B4000 - For lateral travel, see: B5000.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
140
175
225
325
375
460
530
840
1050
1275
1700
2000
2200
2500
2900
3200
3400
3600
4700
5500
6200

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.25
6
3.25
6.5
3.875
6.5
4.375
7
5
7
5.5
7.5
6.062
8.5
7.25
10
8.25
11
9.25
13.5
11.625
15
13.625
17
16.125
17.5
17.125
20.5
19.125
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
39.625
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.375
4
6.5
4.375
4
7
4.875
4
7
5.5
4
7.5
6.0625
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.25
4
12
10.25
4
14
12.625
4
15.5
14.875
4
17.5
17.125
4
18.5
18.125
4
21
20.125
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

Insul. Thk. = 2"


C
E
7
5.375
7
5.375
7.5
5.937
8.5
7
8.5
7
9
8.125
9
8.125
10
9.25
12
10.25
13
11.375
15
13.625
16.5
15.875
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7
4
8.5
7
4
8.5
7
4
9
8
4
9
8
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.375
4
13.5
12.625
6
15.5
14.875
6
17
16.875
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8
9
8
9
8
10
9
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.375
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10
11
10
11
10
12
11.25
12
11.25
12.5
12.25
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
17.875
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

Insul. Thk. = 5"


B
C
E
8
12.5
12.125
8
12.5
12.125
8
12.5
12.25
8
13.5
13.25
8
13.5
13.25
8
14
14.5
8
14
14.625
8
15
15.625
8
16.5
16.875
8
17.5
17.875
8
19
20.125
8
20.5
22.125
8
22.5
24.125
8
23
25.125
8
26
27.375
8
27.5
29.375
8
29
31.375
8
32
35.375
8
38
41.625
8
42.5
48.125
8
46.5
54.125

Application:

Features:

Material Data:

Model B3000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B3000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat Surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B3000U)

48

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/b3000

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

B3000

Model B3100 Guided Insulated Pipe Support

9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

STEEL MOUNTING PLATE


WITH RESTRAINTS

1/8" CLR
TYP
C

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B3200 - For greater axial travel, see: B4100 - For lateral travel, see: B5100
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
280
350
450
650
750
920
1060
1680
2100
2550
3400
4000
4400
5000
5800
6400
6800
7200
9400
11000
12400

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.25
6
3.25
6.5
3.875
6.5
4.5
7
5
7
5.5
7.5
6.187
8.5
7.25
10
8.5
11
9.5
13.5
11.625
15
13.875
17
16.125
17.5
17.125
20.5
19.375
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
40.125
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.375
4
6.5
4.375
4
7
5
4
7
5.5
4
7.5
6.0625
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.5
4
12
10.5
4
14
12.625
4
15.5
15.125
4
17.5
17.125
4
18.5
18.125
4
21
20.375
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
7
5.375
7
5.375
7.5
6.062
8.5
7.125
8.5
7.125
9
8.125
9
8.125
10
9.25
12
10.5
13
11.625
15
13.625
16.5
16.125
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7
4
8.5
7
4
8.5
7
4
9
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.625
4
13.5
12.625
6
15.5
14.875
6
17
17.125
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8
9
8
9
8
10
9.125
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.625
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10
11
10
11
10
12
11.25
12
11.25
12.5
12.25
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
18.125
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
12.5
12.125
12.5
12.25
12.5
12.25
13.5
13.25
13.5
13.25
14
14.5
14
14.625
15
15.625
16.5
16.875
17.5
17.875
19
20.125
20.5
22.125
22.5
24.125
23
25.125
26
27.375
27.5
29.375
29
31.375
32
35.375
38
41.625
42.5
48.125
46.5
54.125

Application:

Features:

Material Data:

Model B3100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B3100: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized.

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B3100U)

www.pipeshields.com/b3100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

49

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

B3000

Model B3200 Guided Insulated Pipe Support


9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

STEEL MOUNTING PLATE


WITH RESTRAINTS

1/8" CLR
TYP
C

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B3300 - For greater axial travel, see: B4200 - For lateral travel, see: B5200.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.375
6
3.375
6.5
4
6.5
4.5
7
5
7
5.5
7.5
6.187
8.5
7.25
10
8.5
11
9.5
13.5
11.625
15
13.875
17
16.125
17.5
17.125
20.5
19.375
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
40.125
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.5
4
6.5
4.5
4
7
5
4
7
5.5
4
7.5
6.0625
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.5
4
12
10.5
4
14
12.625
4
15.5
15.125
4
17.5
17.125
4
18.5
18.125
4
21
20.375
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

Insul. Thk. = 2"


C
E
7
5.5
7
5.5
7.5
6.062
8.5
7.125
8.5
7.125
9
8.125
9
8.125
10
9.25
12
10.5
13
11.625
15
13.625
16.5
16.125
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7.125
4
8.5
7.125
4
8.5
7.125
4
9
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.625
4
13.5
12.625
6
15.5
14.875
6
17
17.125
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8.125
9
8.125
9
8.125
10
9.125
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.625
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10.125
11
10.125
11
10.125
12
11.25
12
11.25
12.5
12.375
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
18.125
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
12.5
12.25
12.5
12.25
12.5
12.25
13.5
13.25
13.5
13.25
14
14.625
14
14.625
15
15.625
16.5
16.875
17.5
17.875
19
20.125
20.5
22.125
22.5
24.125
23
25.125
26
27.375
27.5
29.375
29
31.375
32
35.375
38
41.625
42.5
48.125
46.5
54.125

Application:

Features:

Material Data:

Model B3200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B3200: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B3200U)

50

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/b3200

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

B3000
Model B3300 Guided Insulated
Pipe Support

9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

STEEL MOUNTING PLATE


WITH RESTRAINTS

1/8" CLR
TYP
C

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - For greater axial travel, see: B4300 - For lateral travel, see: B5300
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.375
6
3.375
6.5
4
6.5
4.5
7
5
7
5.5
7.5
6.187
8.5
7.25
10
8.5
11
9.5
13.5
11.625
15
13.875
17
16.125
17.5
17.125
20.5
19.375
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
40.125
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.5
4
6.5
4.5
4
7
5
4
7
5.5
4
7.5
6.0625
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.5
4
12
10.5
4
14
12.625
4
15.5
15.125
4
17.5
17.125
4
18.5
18.125
4
21
20.375
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
7
5.5
7
5.5
7.5
6.062
8.5
7.125
8.5
7.125
9
8.125
9
8.125
10
9.25
12
10.5
13
11.625
15
13.625
16.5
16.125
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7.125
4
8.5
7.125
4
8.5
7.125
4
9
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.625
4
13.5
12.625
6
15.5
14.875
6
17
17.125
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8.125
9
8.125
9
8.125
10
9.125
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.625
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10.125
11
10.125
11
10.125
12
11.25
12
11.25
12.5
12.375
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
18.125
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
12.5
12.25
12.5
12.25
12.5
12.25
13.5
13.25
13.5
13.25
14
14.625
14
14.625
15
15.625
16.5
16.875
17.5
17.875
19
20.125
20.5
22.125
22.5
24.125
23
25.125
26
27.375
27.5
29.375
29
31.375
32
35.375
38
41.625
42.5
48.125
46.5
54.125

Application:

Features:

Material Data:

Model B3300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B3300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium Silicate asbestos-free,
treated with water repellant
Jackets: Galvanized Steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE Optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat Surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B3300U)

www.pipeshields.com/b3300

Easy Installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance Test Results on File:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

51

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B4000 Guided Insulated Pipe Support


B4000
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

1/8" CLR
TYP

12"

STEEL MOUNTING PLATE


WITH RESTRAINTS
POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B4100 - For lateral travel, see: B6000.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
140
175
225
325
375
460
530
840
1050
1275
1700
2000
2200
2500
2900
3200
3400
3600
4700
5500
6200

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.25
6
3.25
6.5
3.875
6.5
4.375
7
5
7
5.5
7.5
6.062
8.5
7.25
10
8.25
11
9.25
13.5
11.625
15
13.625
17
16.125
17.5
17.125
20.5
19.125
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
39.625
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.375
4
6.5
4.375
4
7
4.875
4
7
5.5
4
7.5
6.0625
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.25
4
12
10.25
4
14
12.625
4
15.5
14.875
4
17.5
17.125
4
18.5
18.125
4
21
20.125
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

Insul. Thk. = 2"


C
E
7
5.375
7
5.375
7.5
5.937
8.5
7
8.5
7
9
8.125
9
8.125
10
9.25
12
10.25
13
11.375
15
13.625
16.5
15.875
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7
4
8.5
7
4
8.5
7
4
9
8
4
9
8
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.375
4
13.5
12.625
6
15.5
14.875
6
17
16.875
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8
9
8
9
8
10
9
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.375
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10
11
10
11
10
12
11.25
12
11.25
12.5
12.25
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
17.875
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
12.5
12.125
12.5
12.125
12.5
12.25
13.5
13.25
13.5
13.25
14
14.5
14
14.625
15
15.625
16.5
16.875
17.5
17.875
19
20.125
20.5
22.125
22.5
24.125
23
25.125
26
27.375
27.5
29.375
29
31.375
32
35.375
38
41.625
42.5
48.125
46.5
54.125

Application:

Features:

Material Data:

Model B4000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B4000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE Optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B4000U)

52

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/b4000

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B4100 Guided Insulated Pipe Support


B4000

15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

1/8" CLR
TYP

12"

STEEL MOUNTING PLATE


WITH RESTRAINTS
POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B4200 - For lateral travel, see: B6100.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
280
350
450
650
750
920
1060
1680
2100
2550
3400
4000
4400
5000
5800
6400
6800
7200
9400
11000
12400

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.25
6
3.25
6.5
3.875
6.5
4.5
7
5
7
5.5
7.5
6.187
8.5
7.25
10
8.5
11
9.5
13.5
11.625
15
13.875
17
16.125
17.5
17.125
20.5
19.375
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
40.125
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.375
4
6.5
4.375
4
7
5
4
7
5.5
4
7.5
6.0625
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.5
4
12
10.5
4
14
12.625
4
15.5
15.125
4
17.5
17.125
4
18.5
18.125
4
21
20.375
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
7
5.375
7
5.375
7.5
6.062
8.5
7.125
8.5
7.125
9
8.125
9
8.125
10
9.25
12
10.5
13
11.625
15
13.625
16.5
16.125
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7
4
8.5
7
4
8.5
7
4
9
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.625
4
13.5
12.625
6
15.5
14.875
6
17
17.125
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8
9
8
9
8
10
9.125
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.625
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10
11
10
11
10
12
11.25
12
11.25
12.5
12.25
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
18.125
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
12.5
12.125
12.5
12.25
12.5
12.25
13.5
13.25
13.5
13.25
14
14.5
14
14.625
15
15.625
16.5
16.875
17.5
17.875
19
20.125
20.5
22.125
22.5
24.125
23
25.125
26
27.375
27.5
29.375
29
31.375
32
35.375
38
41.625
42.5
48.125
46.5
54.125

Application:

Features:

Material Data:

Model B4100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B4100: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B4100U)

www.pipeshields.com/b4100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

53

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B4200 Guided Insulated Pipe Support


B4000
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

1/8" CLR
TYP

12"

STEEL MOUNTING PLATE


WITH RESTRAINTS
POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B4300 - For lateral travel, see: B6200.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
400
500
650
950
1100
1350
1600
2500
3100
3800
5100
6000
6600
7500
8700
9600
10200
10800
14100
16500
18600

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.25
6
3.25
6.5
4
6.5
4.5
7
5
7
5.5
7.5
6.187
8.5
7.25
10
8.5
11
9.5
13.5
11.625
15
13.875
17
16.125
17.5
17.125
20.5
19.375
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
40.125
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.375
4
6.5
4.375
4
7
5
4
7
5.5
4
7.5
6.1875
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.5
4
12
10.5
4
14
12.625
4
15.5
15.125
4
17.5
17.125
4
18.5
18.125
4
21
20.375
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

Insul. Thk. = 2"


C
E
7
5.375
7
5.375
7.5
6.062
8.5
7.125
8.5
7.125
9
8.125
9
8.125
10
9.25
12
10.5
13
11.625
15
13.625
16.5
16.125
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7
4
8.5
7
4
8.5
7.125
4
9
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.625
4
13.5
12.625
6
15.5
14.875
6
17
17.125
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8
9
8
9
8.125
10
9.125
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.625
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10
11
10
11
10.125
12
11.25
12
11.25
12.5
12.25
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
18.125
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
12.5
12.125
12.5
12.25
12.5
12.25
13.5
13.25
13.5
13.25
14
14.5
14
14.625
15
15.625
16.5
16.875
17.5
17.875
19
20.125
20.5
22.125
22.5
24.125
23
25.125
26
27.375
27.5
29.375
29
31.375
32
35.375
38
41.625
42.5
48.125
46.5
54.125

Application:

Features:

Material Data:

Model B4200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B4200: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE Optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B4200U)

54

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/b4200

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B4300 Guided Insulated Pipe Support


B4000

15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
1/8" CLR
TYP

T.O.S.
4"

1/8" CLR
TYP

12"

STEEL MOUNTING PLATE


WITH RESTRAINTS
POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 20% of vertical load, contact factory. Available in
all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - For lateral travel, see: B6300.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
6
3.375
6
3.375
6.5
4
6.5
4.5
7
5
7
5.5
7.5
6.187
8.5
7.25
10
8.5
11
9.5
13.5
11.625
15
13.875
17
16.125
17.5
17.125
20.5
19.375
22
21.375
23.5
23.375
26
27.375
32.5
33.625
36.5
40.125
41
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
6.5
4.5
4
6.5
4.5
4
7
5
4
7
5.5
4
7.5
6.0625
4
8.5
7.125
4
8.5
7.125
4
9
8.25
4
11
9.5
4
12
10.5
4
14
12.625
4
15.5
15.125
4
17.5
17.125
4
18.5
18.125
4
21
20.375
4
22.5
22.375
4
24
24.375
4
27
28.375
6
33
34.625
6
37.5
41.125
6
41.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
7
5.5
7
5.5
7.5
6.062
8.5
7.125
8.5
7.125
9
8.125
9
8.125
10
9.25
12
10.5
13
11.625
15
13.625
16.5
16.125
18.5
18.125
19
19.125
22
21.375
23.5
23.375
24.5
25.375
27.5
29.375
34
35.625
38
42.125
42.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
8.5
7.125
4
8.5
7.125
4
8.5
7.125
4
9
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
11
10.25
4
13
11.625
4
13.5
12.625
6
15.5
14.875
6
17
17.125
6
19
19.125
6
19.5
20.125
6
22.5
22.375
6
24
24.375
6
25.5
26.375
6
28.5
30.375
6
34.5
36.625
6
38.5
43.125
6
43
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
9
8.125
9
8.125
9
8.125
10
9.125
10
9.125
11
10.125
11
10.125
12
11.375
13.5
12.625
14.5
13.625
16.5
15.875
18
18.125
19.5
20.125
20.5
21.125
23.5
23.375
24.5
25.375
26
27.375
29
31.375
35
37.625
39.5
44.125
43.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
11
10.125
11
10.125
11
10.125
12
11.25
12
11.25
12.5
12.375
12.5
12.375
13.5
13.375
15
14.875
16
15.875
18
18.125
19
20.125
21
22.125
22
23.125
24.5
25.375
26
27.375
27.5
29.375
30.5
33.375
36.5
39.625
41
46.125
45
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
12.5
12.25
12.5
12.25
12.5
12.25
13.5
13.25
13.5
13.25
14
14.625
14
14.625
15
15.625
16.5
16.875
17.5
17.875
19
20.125
20.5
22.125
22.5
24.125
23
25.125
26
27.375
27.5
29.375
29
31.375
32
35.375
38
41.625
42.5
48.125
46.5
54.125

Application:

Features:

Material Data:

Model B4300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B4300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B4300U)

www.pipeshields.com/b4300

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

55

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B5000 Wide Base Sliding Insulated Pipe Support


B5000

"L" MAX.
LATERAL TRAVEL
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

6"

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B5100 - For greater axial travel, see: B6000 - For lateral restraint, see: B3000 - For lateral travel, see: B1000.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

140
175
225
325
375
460
530
840
1050
1275
1700
2000
2200
2500
2900
3200
3400
3600
4700
5500
6200

Insul. Thk. = 1"


L = +/- 1-1/2
B
C
E
4
5.25
3.25
4
5.25
3.25
4
5.75
3.875
4
6.25
4.375
4
6.75
5
4
7.25
5.5
4
7.75
6.062
4
8.25
7.25
4
9
8.25
4
9.5
9.25
4
10.5
11.625
4
11.5
13.625
4
12.5
16.125
4
13
17.125
4
14
19.125
4
15
21.375
4
16
23.375
4
18.5
27.375
4
23.5
33.625
4
27.5
39.625
4
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
B
C
E
4
6.25
4.375
4
6.25
4.375
4
6.75
4.875
4
7.25
5.5
4
7.75
6.0625
4
8.75
7.125
4
8.75
7.125
4
9.25
8.25
4
10
9.25
4
10.5
10.25
4
11.5
12.625
4
12.5
14.875
4
13.5
17.125
4
14
18.125
4
15
20.125
4
16
22.375
4
17
24.375
4
19.5
28.375
6
24
34.625
6
28.5
41.125
6
32.5
47.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
B
C
E
4
8.75
7
4
8.75
7
4
8.75
7
4
9.75
8
4
9.75
8
4
10.75
9.125
4
10.75
9.125
4
11.25
10.25
4
12
11.375
4
12.5
12.625
6
13.5
14.875
6
14.5
16.875
6
15.5
19.125
6
16
20.125
6
17
22.375
6
18
24.375
6
19
26.375
6
21
30.375
6
25.5
36.625
6
29.5
43.125
6
34
49.125

Insul. Thk. = 3"


L = +/- 2-1/2
B
C
E
6
9.75
8
6
9.75
8
6
9.75
8
6
10.75
9
6
10.75
9.125
6
11.75
10.125
6
11.75
10.125
6
12.25 11.375
6
13
12.375
6
13.5
13.625
6
14.5
15.875
6
15.5
18.125
6
16.5
20.125
6
17
21.125
6
18
23.375
6
19
25.375
6
20
27.375
6
22
31.375
6
26
37.625
6
30.5
44.125
6
34.5
50.125

Insul. Thk. =4"


L = +/- 3
B
C
E
6
11.75
10
6
11.75
10
6
11.75
10
6
12.75
11.25
6
12.75
11.25
6
13.75
12.25
6
13.75 12.375
6
14.25 13.375
6
15
14.875
6
15.5
15.875
6
16.5
17.875
6
17.5
20.125
6
18.5
22.125
6
19
23.125
8
20
25.375
8
21
27.375
8
22
29.375
8
24
33.375
8
27.5
39.625
8
32
46.125
8
36
52.125

Insul. Thk. = 5"


L = +/- 3-1/2
B
C
E
8
13.75 12.125
8
13.75 12.125
8
13.75
12.25
8
14.75
13.25
8
14.75
13.25
8
15.75
14.5
8
15.75 14.625
8
16.25 15.625
8
17
16.875
8
17.5
17.875
8
18.5
20.125
8
19.5
22.125
8
20.5
24.125
8
21
25.125
8
22
27.375
8
23
29.375
8
24
31.375
8
26
35.375
8
29
41.625
8
33.5
48.125
8
37.5
54.125

Application:

Features:

Material Data:

Model B5000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B5000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B5000U)

56

Insul. Thk. = 2"


L = +/- 2
B
C
E
4
7.25
5.375
4
7.25
5.375
4
7.75
5.937
4
8.75
7
4
8.75
7
4
9.75
8.125
4
9.75
8.125
4
10.25
9.25
4
11
10.25
4
11.5
11.375
4
12.5
13.625
4
13.5
15.875
4
14.5
18.125
4
15
19.125
6
16
21.375
6
17
23.375
6
18
25.375
6
20
29.375
6
25
35.625
6
29
42.125
6
33.5
48.125

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/b5000

Model B5100 Wide Base Sliding Insulated Pipe Support


B5000

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

"L" MAX.
LATERAL TRAVEL
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

6"

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B5200 - For greater axial travel, see: B6100 - For lateral restraint, see: B3100 - For lateral travel, see: B1100.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

280
350
450
650
750
920
1060
1680
2100
2550
3400
4000
4400
5000
5800
6400
6800
7200
9400
11000
12400

Insul. Thk. = 1"


L = +/- 1-1/2
B
C
E
4
5.25
3.25
4
5.25
3.25
4
5.75
3.875
4
6.25
4.5
4
6.75
5
4
7.25
5.5
4
7.75
6.187
4
8.25
7.25
4
9
8.5
4
9.5
9.5
4
10.5
11.625
4
11.5
13.875
4
12.5
16.125
4
13
17.125
4
14
19.375
4
15
21.375
4
16
23.375
4
18.5
27.375
4
23.5
33.625
4
27.5
40.125
4
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
B
C
E
4
6.25
4.375
4
6.25
4.375
4
6.75
5
4
7.25
5.5
4
7.75
6.0625
4
8.75
7.125
4
8.75
7.125
4
9.25
8.25
4
10
9.5
4
10.5
10.5
4
11.5
12.625
4
12.5
15.125
4
13.5
17.125
4
14
18.125
4
15
20.375
4
16
22.375
4
17
24.375
4
19.5
28.375
6
24
34.625
6
28.5
41.125
6
32.5
47.125

Insul. Thk. = 2"


L = +/- 2
B
C
E
4
7.25
5.375
4
7.25
5.375
4
7.75
6.062
4
8.75
7.125
4
8.75
7.125
4
9.75
8.125
4
9.75
8.125
4
10.25
9.25
4
11
10.5
4
11.5
11.625
4
12.5
13.625
4
13.5
16.125
4
14.5
18.125
4
15
19.125
6
16
21.375
6
17
23.375
6
18
25.375
6
20
29.375
6
25
35.625
6
29
42.125
6
33.5
48.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
B
C
E
4
8.75
7
4
8.75
7
4
8.75
7
4
9.75
8.125
4
9.75
8.125
4
10.75
9.125
4
10.75
9.125
4
11.25
10.25
4
12
11.625
4
12.5
12.625
6
13.5
14.875
6
14.5
17.125
6
15.5
19.125
6
16
20.125
6
17
22.375
6
18
24.375
6
19
26.375
6
21
30.375
6
25.5
36.625
6
29.5
43.125
6
34
49.125

Insul. Thk. = 3"


L = +/- 2-1/2
B
C
E
6
9.75
8
6
9.75
8
6
9.75
8
6
10.75
9.125
6
10.75
9.125
6
11.75 10.125
6
11.75 10.125
6
12.25 11.375
6
13
12.625
6
13.5
13.625
6
14.5
15.875
6
15.5
18.125
6
16.5
20.125
6
17
21.125
6
18
23.375
6
19
25.375
6
20
27.375
6
22
31.375
6
26
37.625
6
30.5
44.125
6
34.5
50.125

Insul. Thk. =4"


L = +/- 3
B
C
E
6
11.75
10
6
11.75
10
6
11.75
10
6
12.75
11.25
6
12.75
11.25
6
13.75
12.25
6
13.75 12.375
6
14.25 13.375
6
15
14.875
6
15.5
15.875
6
16.5
18.125
6
17.5
20.125
6
18.5
22.125
6
19
23.125
8
20
25.375
8
21
27.375
8
22
29.375
8
24
33.375
8
27.5
39.625
8
32
46.125
8
36
52.125

Insul. Thk. = 5"


L = +/- 3-1/2
B
C
E
8
13.75 12.125
8
13.75
12.25
8
13.75
12.25
8
14.75
13.25
8
14.75
13.25
8
15.75
14.5
8
15.75 14.625
8
16.25 15.625
8
17
16.875
8
17.5
17.875
8
18.5
20.125
8
19.5
22.125
8
20.5
24.125
8
21
25.125
8
22
27.375
8
23
29.375
8
24
31.375
8
26
35.375
8
29
41.625
8
33.5
48.125
8
37.5
54.125

Application:

Features:

Material Data:

Model B5100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B5100: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B5100U)

www.pipeshields.com/b5100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

57

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B5200 Wide Base Sliding Insulated Pipe Support


B5000

"L" MAX.
LATERAL TRAVEL
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

6"

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B5300 - For greater axial travel, see: B6200 - For lateral restraint, see: B3200 - For lateral travel, see: B1200.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

400
500
650
950
1100
1350
1600
2500
3100
3800
5100
6000
6600
7500
8700
9600
10200
10800
14100
16500
18600

Insul. Thk. = 1"


L = +/- 1-1/2
B
C
E
4
5.25
3.25
4
5.25
3.25
4
5.75
4
4
6.25
4.5
4
6.75
5
4
7.25
5.5
4
7.75
6.187
4
8.25
7.25
4
9
8.5
4
9.5
9.5
4
10.5
11.625
4
11.5
13.875
4
12.5
16.125
4
13
17.125
4
14
19.375
4
15
21.375
4
16
23.375
4
18.5
27.375
4
23.5
33.625
4
27.5
40.125
4
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
B
C
E
4
6.25
4.375
4
6.25
4.375
4
6.75
5
4
7.25
5.5
4
7.75
6.1875
4
8.75
7.125
4
8.75
7.125
4
9.25
8.25
4
10
9.5
4
10.5
10.5
4
11.5
12.625
4
12.5
15.125
4
13.5
17.125
4
14
18.125
4
15
20.375
4
16
22.375
4
17
24.375
4
19.5
28.375
6
24
34.625
6
28.5
41.125
6
32.5
47.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
B
C
E
4
8.75
7
4
8.75
7
4
8.75
7.125
4
9.75
8.125
4
9.75
8.125
4
10.75
9.125
4
10.75
9.125
4
11.25
10.25
4
12
11.625
4
12.5
12.625
6
13.5
14.875
6
14.5
17.125
6
15.5
19.125
6
16
20.125
6
17
22.375
6
18
24.375
6
19
26.375
6
21
30.375
6
25.5
36.625
6
29.5
43.125
6
34
49.125

Insul. Thk. = 3"


L = +/- 2-1/2
B
C
E
6
9.75
8
6
9.75
8
6
9.75
8.125
6
10.75
9.125
6
10.75
9.125
6
11.75 10.125
6
11.75 10.125
6
12.25 11.375
6
13
12.625
6
13.5
13.625
6
14.5
15.875
6
15.5
18.125
6
16.5
20.125
6
17
21.125
6
18
23.375
6
19
25.375
6
20
27.375
6
22
31.375
6
26
37.625
6
30.5
44.125
6
34.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


L = +/- 3
C
E
11.75
10
11.75
10
11.75 10.125
12.75
11.25
12.75
11.25
13.75
12.25
13.75 12.375
14.25 13.375
15
14.875
15.5
15.875
16.5
18.125
17.5
20.125
18.5
22.125
19
23.125
20
25.375
21
27.375
22
29.375
24
33.375
27.5
39.625
32
46.125
36
52.125

Insul. Thk. = 5"


L = +/- 3-1/2
B
C
E
8
13.75 12.125
8
13.75
12.25
8
13.75
12.25
8
14.75
13.25
8
14.75
13.25
8
15.75
14.5
8
15.75 14.625
8
16.25 15.625
8
17
16.875
8
17.5
17.875
8
18.5
20.125
8
19.5
22.125
8
20.5
24.125
8
21
25.125
8
22
27.375
8
23
29.375
8
24
31.375
8
26
35.375
8
29
41.625
8
33.5
48.125
8
37.5
54.125

Application:

Features:

Material Data:

Model B5200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B5200: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B5200U)

58

Insul. Thk. = 2"


L = +/- 2
B
C
E
4
7.25
5.375
4
7.25
5.375
4
7.75
6.062
4
8.75
7.125
4
8.75
7.125
4
9.75
8.125
4
9.75
8.125
4
10.25
9.25
4
11
10.5
4
11.5
11.625
4
12.5
13.625
4
13.5
16.125
4
14.5
18.125
4
15
19.125
6
16
21.375
6
17
23.375
6
18
25.375
6
20
29.375
6
25
35.625
6
29
42.125
6
33.5
48.125

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/b5200

Model B5300 Wide Base Sliding Insulated Pipe Support


B5000

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

"L" MAX.
LATERAL TRAVEL
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

6"

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - For greater axial travel, see: B6300 - For lateral restraint, see: B3300 - For lateral travel, see: B1300.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800

Insul. Thk. = 1"


L = +/- 1-1/2
B
C
E
4
5.25
3.375
4
5.25
3.375
4
5.75
4
4
6.25
4.5
4
6.75
5
4
7.25
5.5
4
7.75
6.187
4
8.25
7.25
4
9
8.5
4
9.5
9.5
4
10.5
11.625
4
11.5
13.875
4
12.5
16.125
4
13
17.125
4
14
19.375
4
15
21.375
4
16
23.375
4
18.5
27.375
4
23.5
33.625
4
27.5
40.125
4
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
B
C
E
4
6.25
4.5
4
6.25
4.5
4
6.75
5
4
7.25
5.5
4
7.75
6.0625
4
8.75
7.125
4
8.75
7.125
4
9.25
8.25
4
10
9.5
4
10.5
10.5
4
11.5
12.625
4
12.5
15.125
4
13.5
17.125
4
14
18.125
4
15
20.375
4
16
22.375
4
17
24.375
4
19.5
28.375
6
24
34.625
6
28.5
41.125
6
32.5
47.125

Insul. Thk. = 2"


L = +/- 2
B
C
E
4
7.25
5.5
4
7.25
5.5
4
7.75
6.062
4
8.75
7.125
4
8.75
7.125
4
9.75
8.125
4
9.75
8.125
4
10.25
9.25
4
11
10.5
4
11.5
11.625
4
12.5
13.625
4
13.5
16.125
4
14.5
18.125
4
15
19.125
6
16
21.375
6
17
23.375
6
18
25.375
6
20
29.375
6
25
35.625
6
29
42.125
6
33.5
48.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
B
C
E
4
8.75
7.125
4
8.75
7.125
4
8.75
7.125
4
9.75
8.125
4
9.75
8.125
4
10.75
9.125
4
10.75
9.125
4
11.25
10.25
4
12
11.625
4
12.5
12.625
6
13.5
14.875
6
14.5
17.125
6
15.5
19.125
6
16
20.125
6
17
22.375
6
18
24.375
6
19
26.375
6
21
30.375
6
25.5
36.625
6
29.5
43.125
6
34
49.125

Insul. Thk. = 3"


L = +/- 2-1/2
B
C
E
6
9.75
8.125
6
9.75
8.125
6
9.75
8.125
6
10.75
9.125
6
10.75
9.125
6
11.75 10.125
6
11.75 10.125
6
12.25 11.375
6
13
12.625
6
13.5
13.625
6
14.5
15.875
6
15.5
18.125
6
16.5
20.125
6
17
21.125
6
18
23.375
6
19
25.375
6
20
27.375
6
22
31.375
6
26
37.625
6
30.5
44.125
6
34.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


L = +/- 3
C
E
11.75 10.125
11.75 10.125
11.75 10.125
12.75
11.25
12.75
11.25
13.75 12.375
13.75 12.375
14.25 13.375
15
14.875
15.5
15.875
16.5
18.125
17.5
20.125
18.5
22.125
19
23.125
20
25.375
21
27.375
22
29.375
24
33.375
27.5
39.625
32
46.125
36
52.125

Insul. Thk. = 5"


L = +/- 3-1/2
B
C
E
8
13.75
12.25
8
13.75
12.25
8
13.75
12.25
8
14.75
13.25
8
14.75
13.25
8
15.75
14.625
8
15.75
14.625
8
16.25
15.625
8
17
16.875
8
17.5
17.875
8
18.5
20.125
8
19.5
22.125
8
20.5
24.125
8
21
25.125
8
22
27.375
8
23
29.375
8
24
31.375
8
26
35.375
8
29
41.625
8
33.5
48.125
8
37.5
54.125

Application:

Features:

Material Data:

Model B5300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B5300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE Optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B5300U)

www.pipeshields.com/b5300

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

59

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B6000 Wide Base Sliding Insulated Pipe Support


B6000
B5000

"L" MAX.
LATERAL TRAVEL
E

15"

"L" MAX.
LATERAL TRAVEL

9"

PIPE
B.O.P.

4 1/2" MAX.
AXIAL TRAVEL

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.

T.O.S.
B

3"

T.O.S.

3"

12"

6" MOUNTING PLATE


STEEL

POLYETHYLENE SLIDE PAD


STEEL MOUNTING PLATE
POLYETHYLENE SLIDE PAD

3"

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B6100 - For lateral restraint, see: B4000 - For minimal lateral travel, see: B2000.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

140
175
225
325
375
460
530
840
1050
1275
1700
2000
2200
2500
2900
3200
3400
3600
4700
5500
6200

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


L = +/- 1-1/2
C
E
5.25
3.25
5.25
3.25
5.75
3.875
6.25
4.375
6.75
5
7.25
5.5
7.75
6.062
8.25
7.25
9
8.25
9.5
9.25
10.5
11.625
11.5
13.625
12.5
16.125
13
17.125
14
19.125
15
21.375
16
23.375
18.5
27.375
23.5
33.625
27.5
39.625
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
C
E
6.25
4.375
6.25
4.375
6.75
4.875
7.25
5.5
7.75
6.0625
8.75
7.125
8.75
7.125
9.25
8.25
10
9.25
10.5
10.25
11.5
12.625
12.5
14.875
13.5
17.125
14
18.125
15
20.125
16
22.375
17
24.375
19.5
28.375
24
34.625
28.5
41.125
32.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

Insul. Thk. = 2"


L = +/- 2
C
E
7.25
5.375
7.25
5.375
7.75
5.937
8.75
7
8.75
7
9.75
8.125
9.75
8.125
10.25
9.25
11
10.25
11.5
11.375
12.5
13.625
13.5
15.875
14.5
18.125
15
19.125
16
21.375
17
23.375
18
25.375
20
29.375
25
35.625
29
42.125
33.5
48.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
C
E
8.75
7
8.75
7
8.75
7
9.75
8
9.75
8
10.75
9.125
10.75
9.125
11.25
10.25
12
11.375
12.5
12.625
13.5
14.875
14.5
16.875
15.5
19.125
16
20.125
17
22.375
18
24.375
19
26.375
21
30.375
25.5
36.625
29.5
43.125
34
49.125

B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


L = +/- 2-1/2
C
E
9.75
8
9.75
8
9.75
8
10.75
9
10.75
9.125
11.75 10.125
11.75 10.125
12.25 11.375
13
12.375
13.5
13.625
14.5
15.875
15.5
18.125
16.5
20.125
17
21.125
18
23.375
19
25.375
20
27.375
22
31.375
26
37.625
30.5
44.125
34.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


L = +/- 3
C
E
11.75
10
11.75
10
11.75
10
12.75
11.25
12.75
11.25
13.75
12.25
13.75 12.375
14.25 13.375
15
14.875
15.5
15.875
16.5
17.875
17.5
20.125
18.5
22.125
19
23.125
20
25.375
21
27.375
22
29.375
24
33.375
27.5
39.625
32
46.125
36
52.125

Insul. Thk. = 5"


L = +/- 3-1/2
C
E
13.75
12.125
13.75
12.125
13.75
12.25
14.75
13.25
14.75
13.25
15.75
14.5
15.75
14.625
16.25
15.625
17
16.875
17.5
17.875
18.5
20.125
19.5
22.125
20.5
24.125
21
25.125
22
27.375
23
29.375
24
31.375
26
35.375
29
41.625
33.5
48.125
37.5
54.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Application:

Features:

Material Data:

Model B6000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B6000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE Optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B6000U)

60

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

www.pipeshields.com/b6000

Heavy Duty,
Base Mounted

Model B6100 Wide Base Sliding Insulated Pipe Support


B6000

Pipe
Shields
Inc.

"L" MAX.
LATERAL TRAVEL
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

12"

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B6200 - For lateral restraint, see: B4100 - For minimal lateral travel, see: B2100.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

280
350
450
650
750
920
1060
1680
2100
2550
3400
4000
4400
5000
5800
6400
6800
7200
9400
11000
12400

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


L = +/- 1-1/2
C
E
5.25
3.25
5.25
3.25
5.75
3.875
6.25
4.5
6.75
5
7.25
5.5
7.75
6.187
8.25
7.25
9
8.5
9.5
9.5
10.5
11.625
11.5
13.875
12.5
16.125
13
17.125
14
19.375
15
21.375
16
23.375
18.5
27.375
23.5
33.625
27.5
40.125
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
C
E
6.25
4.375
6.25
4.375
6.75
5
7.25
5.5
7.75
6.0625
8.75
7.125
8.75
7.125
9.25
8.25
10
9.5
10.5
10.5
11.5
12.625
12.5
15.125
13.5
17.125
14
18.125
15
20.375
16
22.375
17
24.375
19.5
28.375
24
34.625
28.5
41.125
32.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


L = +/- 2
C
E
7.25
5.375
7.25
5.375
7.75
6.062
8.75
7.125
8.75
7.125
9.75
8.125
9.75
8.125
10.25
9.25
11
10.5
11.5
11.625
12.5
13.625
13.5
16.125
14.5
18.125
15
19.125
16
21.375
17
23.375
18
25.375
20
29.375
25
35.625
29
42.125
33.5
48.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
C
E
8.75
7
8.75
7
8.75
7
9.75
8.125
9.75
8.125
10.75
9.125
10.75
9.125
11.25
10.25
12
11.625
12.5
12.625
13.5
14.875
14.5
17.125
15.5
19.125
16
20.125
17
22.375
18
24.375
19
26.375
21
30.375
25.5
36.625
29.5
43.125
34
49.125

B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


L = +/- 2-1/2
C
E
9.75
8
9.75
8
9.75
8
10.75
9.125
10.75
9.125
11.75 10.125
11.75 10.125
12.25 11.375
13
12.625
13.5
13.625
14.5
15.875
15.5
18.125
16.5
20.125
17
21.125
18
23.375
19
25.375
20
27.375
22
31.375
26
37.625
30.5
44.125
34.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


L = +/- 3
C
E
11.75
10
11.75
10
11.75
10
12.75
11.25
12.75
11.25
13.75
12.25
13.75 12.375
14.25 13.375
15
14.875
15.5
15.875
16.5
18.125
17.5
20.125
18.5
22.125
19
23.125
20
25.375
21
27.375
22
29.375
24
33.375
27.5
39.625
32
46.125
36
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


L = +/- 3-1/2
C
E
13.75
12.125
13.75
12.25
13.75
12.25
14.75
13.25
14.75
13.25
15.75
14.5
15.75
14.625
16.25
15.625
17
16.875
17.5
17.875
18.5
20.125
19.5
22.125
20.5
24.125
21
25.125
22
27.375
23
29.375
24
31.375
26
35.375
29
41.625
33.5
48.125
37.5
54.125

Application:

Features:

Material Data:

Model B6100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B6100: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B6100U)

www.pipeshields.com/b6100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

61

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B6200 Wide Base Sliding Insulated Pipe Support


B6000

"L" MAX.
LATERAL TRAVEL
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

12"

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B6300 - For lateral restraint, see: B4200 - For minimal lateral travel, see: B2200.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

400
500
650
950
1100
1350
1600
2500
3100
3800
5100
6000
6600
7500
8700
9600
10200
10800
14100
16500
18600

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


L = +/- 1-1/2
C
E
5.25
3.25
5.25
3.25
5.75
4
6.25
4.5
6.75
5
7.25
5.5
7.75
6.187
8.25
7.25
9
8.5
9.5
9.5
10.5
11.625
11.5
13.875
12.5
16.125
13
17.125
14
19.375
15
21.375
16
23.375
18.5
27.375
23.5
33.625
27.5
40.125
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
C
E
6.25
4.375
6.25
4.375
6.75
5
7.25
5.5
7.75
6.1875
8.75
7.125
8.75
7.125
9.25
8.25
10
9.5
10.5
10.5
11.5
12.625
12.5
15.125
13.5
17.125
14
18.125
15
20.375
16
22.375
17
24.375
19.5
28.375
24
34.625
28.5
41.125
32.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

Insul. Thk. = 2"


L = +/- 2
C
E
7.25
5.375
7.25
5.375
7.75
6.062
8.75
7.125
8.75
7.125
9.75
8.125
9.75
8.125
10.25
9.25
11
10.5
11.5
11.625
12.5
13.625
13.5
16.125
14.5
18.125
15
19.125
16
21.375
17
23.375
18
25.375
20
29.375
25
35.625
29
42.125
33.5
48.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
C
E
8.75
7
8.75
7
8.75
7.125
9.75
8.125
9.75
8.125
10.75
9.125
10.75
9.125
11.25
10.25
12
11.625
12.5
12.625
13.5
14.875
14.5
17.125
15.5
19.125
16
20.125
17
22.375
18
24.375
19
26.375
21
30.375
25.5
36.625
29.5
43.125
34
49.125

B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


L = +/- 2-1/2
C
E
9.75
8
9.75
8
9.75
8.125
10.75
9.125
10.75
9.125
11.75 10.125
11.75 10.125
12.25 11.375
13
12.625
13.5
13.625
14.5
15.875
15.5
18.125
16.5
20.125
17
21.125
18
23.375
19
25.375
20
27.375
22
31.375
26
37.625
30.5
44.125
34.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


L = +/- 3
C
E
11.75
10
11.75
10
11.75 10.125
12.75
11.25
12.75
11.25
13.75
12.25
13.75 12.375
14.25 13.375
15
14.875
15.5
15.875
16.5
18.125
17.5
20.125
18.5
22.125
19
23.125
20
25.375
21
27.375
22
29.375
24
33.375
27.5
39.625
32
46.125
36
52.125

Insul. Thk. = 5"


L = +/- 3-1/2
C
E
13.75 12.125
13.75
12.25
13.75
12.25
14.75
13.25
14.75
13.25
15.75
14.5
15.75 14.625
16.25 15.625
17
16.875
17.5
17.875
18.5
20.125
19.5
22.125
20.5
24.125
21
25.125
22
27.375
23
29.375
24
31.375
26
35.375
29
41.625
33.5
48.125
37.5
54.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Application:

Features:

Material Data:

Model B6200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B6200: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized.

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B6200U)

62

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/b6200

Heavy Duty,
Base Mounted

Model B6300 Wide Base Sliding Insulated Pipe Support


B6000

Pipe
Shields
Inc.

"L" MAX.
LATERAL TRAVEL
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.
3"

12"

STEEL MOUNTING PLATE


POLYETHYLENE SLIDE PAD

3"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - For lateral restraint, see: B4300 - For minimal lateral travel, see: B2300.
Pipe
Size

Vert.
Load

1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

550
700
900
1300
1500
1800
2100
3350
4200
5100
6800
8000
8800
10000
11600
12800
13600
14400
18800
22000
24800

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


L = +/- 1-1/2
C
E
5.25
3.375
5.25
3.375
5.75
4
6.25
4.5
6.75
5
7.25
5.5
7.75
6.187
8.25
7.25
9
8.5
9.5
9.5
10.5
11.625
11.5
13.875
12.5
16.125
13
17.125
14
19.375
15
21.375
16
23.375
18.5
27.375
23.5
33.625
27.5
40.125
32
46.125

Insul. Thk. = 1-1/2"


L = +/- 1-3/4
C
E
6.25
4.5
6.25
4.5
6.75
5
7.25
5.5
7.75
6.0625
8.75
7.125
8.75
7.125
9.25
8.25
10
9.5
10.5
10.5
11.5
12.625
12.5
15.125
13.5
17.125
14
18.125
15
20.375
16
22.375
17
24.375
19.5
28.375
24
34.625
28.5
41.125
32.5
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


L = +/- 2
C
E
7.25
5.5
7.25
5.5
7.75
6.062
8.75
7.125
8.75
7.125
9.75
8.125
9.75
8.125
10.25
9.25
11
10.5
11.5
11.625
12.5
13.625
13.5
16.125
14.5
18.125
15
19.125
16
21.375
17
23.375
18
25.375
20
29.375
25
35.625
29
42.125
33.5
48.125

Insul. Thk. = 2-1/2"


L = +/- 2-1/4
C
E
8.75
7.125
8.75
7.125
8.75
7.125
9.75
8.125
9.75
8.125
10.75
9.125
10.75
9.125
11.25
10.25
12
11.625
12.5
12.625
13.5
14.875
14.5
17.125
15.5
19.125
16
20.125
17
22.375
18
24.375
19
26.375
21
30.375
25.5
36.625
29.5
43.125
34
49.125

B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


L = +/- 2-1/2
C
E
9.75
8.125
9.75
8.125
9.75
8.125
10.75
9.125
10.75
9.125
11.75 10.125
11.75 10.125
12.25 11.375
13
12.625
13.5
13.625
14.5
15.875
15.5
18.125
16.5
20.125
17
21.125
18
23.375
19
25.375
20
27.375
22
31.375
26
37.625
30.5
44.125
34.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


L = +/- 3
C
E
11.75 10.125
11.75 10.125
11.75 10.125
12.75
11.25
12.75
11.25
13.75 12.375
13.75 12.375
14.25 13.375
15
14.875
15.5
15.875
16.5
18.125
17.5
20.125
18.5
22.125
19
23.125
20
25.375
21
27.375
22
29.375
24
33.375
27.5
39.625
32
46.125
36
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


L = +/- 3-1/2
C
E
13.75
12.25
13.75
12.25
13.75
12.25
14.75
13.25
14.75
13.25
15.75
14.625
15.75
14.625
16.25
15.625
17
16.875
17.5
17.875
18.5
20.125
19.5
22.125
20.5
24.125
21
25.125
22
27.375
23
29.375
24
31.375
26
35.375
29
41.625
33.5
48.125
37.5
54.125

Application:

Features:

Material Data:

Model B6300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B6300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B6300U)

www.pipeshields.com/b6300

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

63

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B7000 Laterally Restrained Insulated Pipe Support


B7000
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

4"

1/8" CLR
TYP

STEEL MOUNTING PLATE

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B7100 - For greater axial travel, see: B8000 - For lateral travel, see: B5000.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
125
155
200
290
335
410
475
750
940
1140
1500
1800
1950
2250
2600
2850
3050
3200
4200
4900
5550

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
3.5
3.25
3.5
3.25
4
3.875
4
4.375
4.5
5
4.5
5.5
6.5
6.062
7.5
7.25
8
8.25
9
9.25
11
11.625
13.5
13.625
15
16.125
16
17.125
17.5
19.125
19.5
21.375
21
23.375
24
27.375
29.5
33.625
34
39.625
39
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
4
4.375
4
4
4.375
4
4.5
4.875
4
4.5
5.5
4
5
6.0625
4
6
7.125
4
7.5
7.125
4
8
8.25
4
9
9.25
4
10
10.25
4
11.5
12.625
4
14
14.875
4
15.5
17.125
4
17
18.125
4
18
20.125
4
20
22.375
4
21.5
24.375
4
25
28.375
6
30
34.625
6
35
41.125
6
39.5
47.125

Insul. Thk. = 2"


C
E
4.5
5.375
4.5
5.375
5
5.937
6
7
6
7
6.5
8.125
8
8.125
9
9.25
10
10.25
11
11.375
12.5
13.625
15
15.875
16.5
18.125
17.5
19.125
19
21.375
21
23.375
22
25.375
25.5
29.375
31
35.625
35.5
42.125
40.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
6
7
4
6
7
4
6
7
4
6.5
8
4
6.5
8
4
7.5
9.125
4
9
9.125
4
10
10.25
4
11
11.375
4
11.5
12.625
6
13
14.875
6
15.5
16.875
6
17
19.125
6
18
20.125
6
19.5
22.375
6
21.5
24.375
6
23
26.375
6
26.5
30.375
6
31.5
36.625
6
36
43.125
6
41
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
6.5
8
6.5
8
6.5
8
7.5
9
7.5
9.125
8.5
10.125
10
10.125
11
11.375
11.5
12.375
12.5
13.625
14
15.875
16.5
18.125
17.5
20.125
19
21.125
20.5
23.375
22
25.375
23.5
27.375
27
31.375
32
37.625
37
44.125
41.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
8.5
10
8.5
10
8.5
10
9.5
11.25
9.5
11.25
10
12.25
11.5
12.375
12.5
13.375
13
14.875
14
15.875
15.5
17.875
17.5
20.125
19
22.125
20.5
23.125
21.5
25.375
23.5
27.375
25
29.375
28.5
33.375
33.5
39.625
38.5
46.125
43
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
10
12.125
10
12.125
10
12.25
11
13.25
11
13.25
11.5
14.5
13
14.625
14
15.625
14.5
16.875
15.5
17.875
16.5
20.125
19
22.125
20.5
24.125
21.5
25.125
23
27.375
25
29.375
26.5
31.375
30
35.375
35
41.625
40
48.125
44.5
54.125

Application:

Features:

Material Data:

Model B7000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B7000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium Silicate asbestos-free,
treated with water repellant
Jackets: Galvanized Steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B7000U)

64

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

www.pipeshields.com/b7000

Model B7100 Laterally Restrained Insulated Pipe Support

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

B7000
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

1/8" CLR
TYP

4"
C

STEEL MOUNTING PLATE

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B7200 - For lateral restraint, see: B8100 - For minimal lateral travel, see: B5100.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
250
310
400
580
670
820
950
1500
1880
2280
3000
3600
3900
4500
5200
5700
6100
6400
8400
9800
11100

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
5
3.25
5
3.25
5.5
3.875
5.5
4.5
6
5
6.5
5.5
7
6.187
8.5
7.25
9.5
8.5
10
9.5
13
11.625
14.5
13.875
16.5
16.125
17.5
17.125
19
19.375
21
21.375
22.5
23.375
25.5
27.375
31.5
33.625
36
40.125
41.5
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
5.5
4.375
4
5.5
4.375
4
6
5
4
6
5.5
4
6.5
6.0625
4
8
7.125
4
8
7.125
4
9
8.25
4
10.5
9.5
4
11
10.5
4
13.5
12.625
4
15
15.125
4
17
17.125
4
18.5
18.125
4
19.5
20.375
4
21.5
22.375
4
23
24.375
4
26.5
28.375
6
32
34.625
6
37
41.125
6
42
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
6
5.375
6
5.375
6.5
6.062
7.5
7.125
7.5
7.125
8.5
8.125
8.5
8.125
10
9.25
11.5
10.5
12
11.625
14.5
13.625
16
16.125
18
18.125
19
19.125
20.5
21.375
22.5
23.375
23.5
25.375
27
29.375
33
35.625
37.5
42.125
43
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
7.5
7
4
7.5
7
4
7.5
7
4
8
8.125
4
8
8.125
4
9.5
9.125
4
9.5
9.125
4
11
10.25
4
12.5
11.625
4
12.5
12.625
6
15
14.875
6
16.5
17.125
6
18.5
19.125
6
19.5
20.125
6
21
22.375
6
23
24.375
6
24.5
26.375
6
28
30.375
6
33.5
36.625
6
38
43.125
6
43.5
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
8
8
8
8
8
8
9
9.125
9
9.125
10.5
10.125
10.5
10.125
12
11.375
13
12.625
13.5
13.625
16
15.875
17.5
18.125
19
20.125
20.5
21.125
22
23.375
23.5
25.375
25
27.375
28.5
31.375
34
37.625
39
44.125
44
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
10
10
10
10
10
10
11
11.25
11
11.25
12
12.25
12
12.375
13.5
13.375
14.5
14.875
15
15.875
17.5
18.125
18.5
20.125
20.5
22.125
22
23.125
23
25.375
25
27.375
26.5
29.375
30
33.375
35.5
39.625
40.5
46.125
45.5
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
11.5
12.125
11.5
12.25
11.5
12.25
12.5
13.25
12.5
13.25
13.5
14.5
13.5
14.625
15
15.625
16
16.875
16.5
17.875
18.5
20.125
20
22.125
22
24.125
23
25.125
24.5
27.375
26.5
29.375
28
31.375
31.5
35.375
37
41.625
42
48.125
47
54.125

Application:

Features:

Material Data:

Model B7100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B7100: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B7100U)

www.pipeshields.com/b7100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

65

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B7200 Laterally Restrained Insulated Pipe Support


B7000
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

1/8" CLR
TYP

4"
C

STEEL MOUNTING PLATE

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B7300 - For greater axial travel, see: B8200 - For lateral travel, see: B5200.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
375
465
600
870
1005
1230
1425
2250
2820
3420
4500
5400
5850
6750
7800
8550
9150
9600
12600
14700
16650

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
5
3.25
5
3.25
5.5
4
6
4.5
7
5
7
5.5
7.5
6.187
9.5
7.25
12.5
8.5
12
9.5
16
11.625
19
13.875
21
16.125
22
17.125
23.5
19.375
25.5
21.375
28
23.375
31
27.375
37
33.625
43
40.125
49
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
5.5
4.375
4
5.5
4.375
4
6
5
4
6.5
5.5
4
7.5
6.1875
4
8.5
7.125
4
8.5
7.125
4
10
8.25
4
13
9.5
4
13.5
10.5
4
17
12.625
4
19.5
15.125
4
21.5
17.125
4
23
18.125
4
24
20.375
4
26.5
22.375
4
28.5
24.375
4
32
28.375
6
38
34.625
6
43.5
41.125
6
50
47.125

Insul. Thk. = 2"


C
E
6
5.375
6
5.375
6.5
6.062
8
7.125
8.5
7.125
9
8.125
9
8.125
11
9.25
14.5
10.5
15
11.625
18.5
13.625
20.5
16.125
22.5
18.125
24
19.125
25
21.375
27.5
23.375
29
25.375
32.5
29.375
38.5
35.625
44.5
42.125
51
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
7.5
7
4
7.5
7
4
7.5
7.125
4
8.5
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
12
10.25
4
16
11.625
4
16
12.625
6
19
14.875
6
21
17.125
6
23.5
19.125
6
24.5
20.125
6
26
22.375
6
28
24.375
6
29.5
26.375
6
33
30.375
6
39.5
36.625
6
45.5
43.125
6
51.5
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
8
8
8
8
8
8.125
9.5
9.125
10
9.125
11
10.125
11
10.125
13
11.375
17
12.625
17.5
13.625
20
15.875
22
18.125
24
20.125
25.5
21.125
27
23.375
28.5
25.375
30
27.375
34
31.375
40.5
37.625
46
44.125
52.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
10
10
10
10
10
10.125
11.5
11.25
12
11.25
12.5
12.25
12.5
12.375
14.5
13.375
19
14.875
18.5
15.875
21.5
18.125
23.5
20.125
26
22.125
27.5
23.125
28
25.375
29.5
27.375
31.5
29.375
35.5
33.375
42
39.625
47.5
46.125
54
52.125

Insul. Thk. = 5"


B
C
E
8
11.5
12.125
8
11.5
12.25
8
11.5
12.25
8
13
13.25
8
13.5
13.25
8
14
14.5
8
14
14.625
8
16
15.625
8
20.5
16.875
8
20.5
17.875
8
23
20.125
8
25.5
22.125
8
27.5
24.125
8
28.5
25.125
8
29
27.375
8
31
29.375
8
33
31.375
8
37
35.375
8
43.5
41.625
8
49.5
48.125
8
55.5
54.125

Application:

Features:

Material Data:

Model B7200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B7200: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat Surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B7200U)

66

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

www.pipeshields.com/b7200

Model B7300 Laterally Restrained Insulated Pipe Support

Heavy Duty,
Base Mounted

Pipe
Shields
Inc.

B7000
9"

PIPE

1 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

4"

1/8" CLR
TYP

STEEL MOUNTING PLATE

6"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - For greater axial travel, see: B8300 - For lateral travel, see: B5300.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
500
620
800
1160
1340
1640
1900
3000
3760
4560
6000
7200
7800
9000
10400
11400
12200
12800
16800
19600
22200

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
5
3.375
5
3.375
5.5
4
6
4.5
7
5
7
5.5
8
6.187
10
7.25
13
8.5
13
9.5
17
11.625
20
13.875
21.5
16.125
22.5
17.125
24.5
19.375
26.5
21.375
29
23.375
31.5
27.375
37.5
33.625
44
40.125
50
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
5.5
4.5
4
5.5
4.5
4
6
5
4
6.5
5.5
4
7.5
6.0625
4
8.5
7.125
4
9
7.125
4
10.5
8.25
4
13.5
9.5
4
14.5
10.5
4
18
12.625
4
20.5
15.125
4
22
17.125
4
23.5
18.125
4
25
20.375
4
27.5
22.375
4
29.5
24.375
4
32.5
28.375
6
38.5
34.625
6
44.5
41.125
6
51
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
6
5.5
6
5.5
6.5
6.062
8
7.125
8.5
7.125
9
8.125
9.5
8.125
11.5
9.25
15
10.5
16
11.625
19.5
13.625
21.5
16.125
23
18.125
24.5
19.125
26
21.375
28.5
23.375
30
25.375
33
29.375
39
35.625
45.5
42.125
52
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
7.5
7.125
4
7.5
7.125
4
7.5
7.125
4
8.5
8.125
4
9
8.125
4
10
9.125
4
10.5
9.125
4
12.5
10.25
4
16.5
11.625
4
17
12.625
6
20
14.875
6
22
17.125
6
24
19.125
6
25
20.125
6
27
22.375
6
29
24.375
6
30.5
26.375
6
33.5
30.375
6
40
37.125
6
46.5
43.125
6
52.5
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
8
8.125
8
8.125
8
8.125
9.5
9.125
10
9.125
11
10.125
11.5
10.125
13.5
11.375
17.5
12.625
18.5
13.625
21
15.875
23
18.125
24.5
20.125
26
21.125
28
23.375
29.5
25.375
31
27.375
34.5
31.375
41
38.125
47
44.125
53.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
10
10.125
10
10.125
10
10.125
11.5
11.25
12
11.25
12.5
12.375
13
12.375
15
13.375
19.5
14.875
19.5
15.875
22.5
18.125
24.5
20.125
26.5
22.125
28
23.375
29
25.375
30.5
27.375
32.5
29.375
36
33.625
42.5
40.125
48.5
46.125
55
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
11.5
12.25
11.5
12.25
11.5
12.25
13
13.25
13.5
13.25
14
14.625
14.5
14.625
16.5
15.625
21
16.875
21.5
17.875
24
20.125
26.5
22.125
28
24.375
29
25.375
30
27.375
32
29.375
34
31.375
37.5
35.625
44
42.125
50.5
48.125
56.5
54.125

Application:

Features:

Material Data:

Model B7300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B7300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B7300U)

www.pipeshields.com/b7300

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

67

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B8000 Laterally Restrained Insulated Pipe Support


B8000
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

4"

1/8" CLR
TYP

STEEL MOUNTING PLATE

12"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B8100 - For lateral travel, see: B6000.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
125
155
200
290
335
410
475
750
940
1140
1500
1800
1950
2250
2600
2850
3050
3200
4200
4900
5550

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
3.5
3.25
3.5
3.25
4
3.875
4
4.375
4.5
5
4.5
5.5
6.5
6.062
7.5
7.25
8
8.25
9
9.25
11
11.625
13.5
13.625
15
16.125
16
17.125
17.5
19.125
19.5
21.375
21
23.375
24
27.375
29.5
33.625
34
39.625
39
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
4
4.375
4
4
4.375
4
4.5
4.875
4
4.5
5.5
4
5
6.0625
4
6
7.125
4
7.5
7.125
4
8
8.25
4
9
9.25
4
10
10.25
4
11.5
12.625
4
14
14.875
4
15.5
17.125
4
17
18.125
4
18
20.125
4
20
22.375
4
21.5
24.375
4
25
28.375
6
30
34.625
6
35
41.125
6
39.5
47.125

Insul. Thk. = 2"


C
E
4.5
5.375
4.5
5.375
5
5.937
6
7
6
7
6.5
8.125
8
8.125
9
9.25
10
10.25
11
11.375
12.5
13.625
15
15.875
16.5
18.125
17.5
19.125
19
21.375
21
23.375
22
25.375
25.5
29.375
31
35.625
35.5
42.125
40.5
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
6
7
4
6
7
4
6
7
4
6.5
8
4
6.5
8
4
7.5
9.125
4
9
9.125
4
10
10.25
4
11
11.375
4
11.5
12.625
6
13
14.875
6
15.5
16.875
6
17
19.125
6
18
20.125
6
19.5
22.375
6
21.5
24.375
6
23
26.375
6
26.5
30.375
6
31.5
36.625
6
36
43.125
6
41
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
6.5
8
6.5
8
6.5
8
7.5
9
7.5
9.125
8.5
10.125
10
10.125
11
11.375
11.5
12.375
12.5
13.625
14
15.875
16.5
18.125
17.5
20.125
19
21.125
20.5
23.375
22
25.375
23.5
27.375
27
31.375
32
37.625
37
44.125
41.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
8.5
10
8.5
10
8.5
10
9.5
11.25
9.5
11.25
10
12.25
11.5
12.375
12.5
13.375
13
14.875
14
15.875
15.5
17.875
17.5
20.125
19
22.125
20.5
23.125
21.5
25.375
23.5
27.375
25
29.375
28.5
33.375
33.5
39.625
38.5
46.125
43
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
10
12.125
10
12.125
10
12.25
11
13.25
11
13.25
11.5
14.5
13
14.625
14
15.625
14.5
16.875
15.5
17.875
16.5
20.125
19
22.125
20.5
24.125
21.5
25.125
23
27.375
25
29.375
26.5
31.375
30
35.375
35
41.625
40
48.125
44.5
54.125

Application:

Features:

Material Data:

Model B8000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B8000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium Silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B8000U)

68

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

www.pipeshields.com/b8000

Model B8100 Laterally Restrained Insulated Pipe Support

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

B8000
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

1/8" CLR
TYP

4"
C

STEEL MOUNTING PLATE

12"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B8200 - For lateral travel, see: B6100.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
250
310
400
580
670
820
950
1500
1880
2280
3000
3600
3900
4500
5200
5700
6100
6400
8400
9800
11100

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
5
3.25
5
3.25
5.5
3.875
5.5
4.5
6
5
6.5
5.5
7
6.187
8.5
7.25
9.5
8.5
10
9.5
13
11.625
14.5
13.875
16.5
16.125
17.5
17.125
19
19.375
21
21.375
22.5
23.375
25.5
27.375
31.5
33.625
36
40.125
41.5
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
5.5
4.375
4
5.5
4.375
4
6
5
4
6
5.5
4
6.5
6.0625
4
8
7.125
4
8
7.125
4
9
8.25
4
10.5
9.5
4
11
10.5
4
13.5
12.625
4
15
15.125
4
17
17.125
4
18.5
18.125
4
19.5
20.375
4
21.5
22.375
4
23
24.375
4
26.5
28.375
6
32
34.625
6
37
41.125
6
42
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
6
5.375
6
5.375
6.5
6.062
7.5
7.125
7.5
7.125
8.5
8.125
8.5
8.125
10
9.25
11.5
10.5
12
11.625
14.5
13.625
16
16.125
18
18.125
19
19.125
20.5
21.375
22.5
23.375
23.5
25.375
27
29.375
33
35.625
37.5
42.125
43
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
7.5
7
4
7.5
7
4
7.5
7
4
8
8.125
4
8
8.125
4
9.5
9.125
4
9.5
9.125
4
11
10.25
4
12.5
11.625
4
12.5
12.625
6
15
14.875
6
16.5
17.125
6
18.5
19.125
6
19.5
20.125
6
21
22.375
6
23
24.375
6
24.5
26.375
6
28
30.375
6
33.5
36.625
6
38
43.125
6
43.5
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
8
8
8
8
8
8
9
9.125
9
9.125
10.5
10.125
10.5
10.125
12
11.375
13
12.625
13.5
13.625
16
15.875
17.5
18.125
19
20.125
20.5
21.125
22
23.375
23.5
25.375
25
27.375
28.5
31.375
34
37.625
39
44.125
44
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
10
10
10
10
10
10
11
11.25
11
11.25
12
12.25
12
12.375
13.5
13.375
14.5
14.875
15
15.875
17.5
18.125
18.5
20.125
20.5
22.125
22
23.125
23
25.375
25
27.375
26.5
29.375
30
33.375
35.5
39.625
40.5
46.125
45.5
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
11.5
12.125
11.5
12.25
11.5
12.25
12.5
13.25
12.5
13.25
13.5
14.5
13.5
14.625
15
15.625
16
16.875
16.5
17.875
18.5
20.125
20
22.125
22
24.125
23
25.125
24.5
27.375
26.5
29.375
28
31.375
31.5
35.375
37
41.625
42
48.125
47
54.125

Application:

Features:

Material Data:

Model B8100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B8100: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized Steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon Steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE Optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat Surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B8100U)

www.pipeshields.com/b8100

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

69

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

Model B8200 Laterally Restrained Insulated Pipe Support


B8000
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

1/8" CLR
TYP

4"
C

STEEL MOUNTING PLATE

12"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: B8300 - For lateral travel, see: B6200.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
375
465
600
870
1005
1230
1425
2250
2820
3420
4500
5400
5850
6750
7800
8550
9150
9600
12600
14700
16650

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
5
3.25
5
3.25
5.5
4
6
4.5
7
5
7
5.5
7.5
6.187
9.5
7.25
12.5
8.5
12
9.5
16
11.625
19
13.875
21
16.125
22
17.125
23.5
19.375
25.5
21.375
28
23.375
31
27.375
37
33.625
43
40.125
49
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
5.5
4.375
4
5.5
4.375
4
6
5
4
6.5
5.5
4
7.5
6.1875
4
8.5
7.125
4
8.5
7.125
4
10
8.25
4
13
9.5
4
13.5
10.5
4
17
12.625
4
19.5
15.125
4
21.5
17.125
4
23
18.125
4
24
20.375
4
26.5
22.375
4
28.5
24.375
4
32
28.375
6
38
34.625
6
43.5
41.125
6
50
47.125

Insul. Thk. = 2"


C
E
6
5.375
6
5.375
6.5
6.062
8
7.125
8.5
7.125
9
8.125
9
8.125
11
9.25
14.5
10.5
15
11.625
18.5
13.625
20.5
16.125
22.5
18.125
24
19.125
25
21.375
27.5
23.375
29
25.375
32.5
29.375
38.5
35.625
44.5
42.125
51
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
7.5
7
4
7.5
7
4
7.5
7.125
4
8.5
8.125
4
9
8.125
4
10
9.125
4
10
9.125
4
12
10.25
4
16
11.625
4
16
12.625
6
19
14.875
6
21
17.125
6
23.5
19.125
6
24.5
20.125
6
26
22.375
6
28
24.375
6
29.5
26.375
6
33
30.375
6
39.5
36.625
6
45.5
43.125
6
51.5
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
8
8
8
8
8
8.125
9.5
9.125
10
9.125
11
10.125
11
10.125
13
11.375
17
12.625
17.5
13.625
20
15.875
22
18.125
24
20.125
25.5
21.125
27
23.375
28.5
25.375
30
27.375
34
31.375
40.5
37.625
46
44.125
52.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
10
10
10
10
10
10.125
11.5
11.25
12
11.25
12.5
12.25
12.5
12.375
14.5
13.375
19
14.875
18.5
15.875
21.5
18.125
23.5
20.125
26
22.125
27.5
23.125
28
25.375
29.5
27.375
31.5
29.375
35.5
33.375
42
39.625
47.5
46.125
54
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
11.5
12.125
11.5
12.25
11.5
12.25
13
13.25
13.5
13.25
14
14.5
14
14.625
16
15.625
20.5
16.875
20.5
17.875
23
20.125
25.5
22.125
27.5
24.125
28.5
25.125
29
27.375
31
29.375
33
31.375
37
35.375
43.5
41.625
49.5
48.125
55.5
54.125

Application:

Features:

Material Data:

Model B8200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B8200: Applicable PSI spec. doc.: No. 209


Insulation: Calcium Silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat Surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B8200U)

70

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal Submittal Sheets available

www.pipeshields.com/b8200

Model B8300 Laterally Restrained Insulated Pipe Support

Pipe
Shields
Inc.

Heavy Duty,
Base Mounted

B8000
15"

PIPE

4 1/2" MAX.
AXIAL TRAVEL

B.O.P.
B

T.O.S.

1/8" CLR
TYP

4"
C

STEEL MOUNTING PLATE

12"

POLYETHYLENE SLIDE PAD

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. If lateral load is greater than 50% of actual vertical load, contact factory. Available
in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - For lateral travel, see: B6300.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert.
Load
500
620
800
1160
1340
1640
1900
3000
3760
4560
6000
7200
7800
9000
10400
11400
12200
12800
16800
19600
22200

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Insul. Thk. = 1"


C
E
5
3.375
5
3.375
5.5
4
6
4.5
7
5
7
5.5
8
6.187
10
7.25
13
8.5
13
9.5
17
11.625
20
13.875
21.5
16.125
22.5
17.125
24.5
19.375
26.5
21.375
29
23.375
31.5
27.375
37.5
33.625
44
40.125
50
46.125

Insul. Thk. = 1-1/2"


B
C
E
4
5.5
4.5
4
5.5
4.5
4
6
5
4
6.5
5.5
4
7.5
6.0625
4
8.5
7.125
4
9
7.125
4
10.5
8.25
4
13.5
9.5
4
14.5
10.5
4
18
12.625
4
20.5
15.125
4
22
17.125
4
23.5
18.125
4
25
20.375
4
27.5
22.375
4
29.5
24.375
4
32.5
28.375
6
38.5
34.625
6
44.5
41.125
6
51
47.125

B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

Insul. Thk. = 2"


C
E
6
5.5
6
5.5
6.5
6.062
8
7.125
8.5
7.125
9
8.125
9.5
8.125
11.5
9.25
15
10.5
16
11.625
19.5
13.625
21.5
16.125
23
18.125
24.5
19.125
26
21.375
28.5
23.375
30
25.375
33
29.375
39
35.625
45.5
42.125
52
48.125

Insul. Thk. = 2-1/2"


B
C
E
4
7.5
7.125
4
7.5
7.125
4
7.5
7.125
4
8.5
8.125
4
9
8.125
4
10
9.125
4
10.5
9.125
4
12.5
10.25
4
16.5
11.625
4
17
12.625
6
20
14.875
6
22
17.125
6
24
19.125
6
25
20.125
6
27
22.375
6
29
24.375
6
30.5
26.375
6
33.5
30.375
6
40
37.125
6
46.5
43.125
6
52.5
49.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Insul. Thk. = 3"


C
E
8
8.125
8
8.125
8
8.125
9.5
9.125
10
9.125
11
10.125
11.5
10.125
13.5
11.375
17.5
12.625
18.5
13.625
21
15.875
23
18.125
24.5
20.125
26
21.125
28
23.375
29.5
25.375
31
27.375
34.5
31.375
41
38.125
47
44.125
53.5
50.125

B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

Insul. Thk. =4"


C
E
10
10.125
10
10.125
10
10.125
11.5
11.25
12
11.25
12.5
12.375
13
12.375
15
13.375
19.5
14.875
19.5
15.875
22.5
18.125
24.5
20.125
26.5
22.125
28
23.375
29
25.375
30.5
27.375
32.5
29.375
36
33.625
42.5
40.125
48.5
46.125
55
52.125

B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

Insul. Thk. = 5"


C
E
11.5
12.25
11.5
12.25
11.5
12.25
13
13.25
13.5
13.25
14
14.625
14.5
14.625
16.5
15.625
21
16.875
21.5
17.875
24
20.125
26.5
22.125
28
24.375
29
25.375
30
27.375
32
29.375
34
31.375
37.5
35.625
44
42.125
50.5
48.125
56.5
54.125

Application:

Features:

Material Data:

Model B8300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes

B8300: Applicable PSI spec. doc.: No. 209


Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Slide Pad: UHMW Polyethylene (PTFE optional)
Coating: Primer coated or hot dipped galvanized

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., B8300U)

www.pipeshields.com/b8300

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Stainless steel to UHMW polyethylene slide
Other I.D.s and/or O.D.s available on request
Factory mounted polyethylene slide pad on steel
mounting plate
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

71

Pipe
Shields
Inc.

Introduction: Section C

INTRODUCTION
SECTION C
PIPE ANCHORS
APPLICATION Heavy Industrial and Large HVAC Distribution Systems
TYPES Welded and Insulated
Note: These anchors have been designed to provide dimensional compatibility with the base
mounted supports in Section B.
Models C1000

Welded Tee Anchor for carbon steel pipe sizes 3 to 6. See Product
Data Sheet for model numbers used with other pipe materials.

Models C1100

Welded Tee No Moment Anchor for carbon steel pipe sizes 3 to 6.


No weld required to sub-structure. See Product Data Sheet for model numbers
used with other pipe materials.

Models C2000

Welded Anchor similar to C1000 except for 8 pipe and larger.

Models C2100

Welded No Moment Anchor similar to C1100 except for 8 pipe and larger.

Models C3000 - C3300

Friction Anchors for relatively light axial forces and infrequent thermal
cycling. The higher the model number in this series, the higher the load rating.

Models C4000 - C4300

Insulated Positive Anchors for heavy axial forces. The higher the model
number in this series, the higher the load rating.

If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at
707-447-5014 or 1-800-538-7007.

Please acquaint yourself with the selection guide at the front of this catalog and the section index
on the page following this introduction, for assistance in determining the most appropriate support
for your application.

72

Pipe
Shields
Inc.

Section C Index

WELDED PIPE ANCHORS


MODEL

PIPE
SIZE
RANGE

INSULATION

FIELD
WELD TO
PIPE

C1000

3-6

NO

YES

YES

HEAVIEST

3-6

NO

YES

NO

HEAVIEST

8 - 30

NO

YES

HEAVIEST

8 - 30

NO

YES

NO

HEAVIEST

YES
YES
YES
YES

NO
NO
NO
NO

NO
NO
NO
NO

LIGHTEST
LIGHTER
LIGHT
MED/LIGHT

YES
YES
YES
YES

YES
YES
YES
YES

NO
NO
NO
NO

LIGHTEST
LIGHTER
LIGHT
MED/LIGHT

C1000

C1100

C2000

C2100

C1100

C2000

C3000

C2100

C4000

C3000
C3100
C3200
C3300

1/2
1/2
1/2
1/2

C4000
C4100
C4200
C4300

1
1
1
1

42
42
42
42

42
42
42
42

ROTATIONAL
RESTRAINT

YES

AXIAL LOAD
CAPACITY

TO ORDER, specify:
1. Quantity 20
2. Pipe Size & Type
4 IPS
3. Insulation Thickness
2
4. Model Number
C1000
EXAMPLE: (20) 4

www.pipeshields.com/c-series

C1000

73

Pipe
Shields
Inc.

Model C1000, Model C1010,


Model C1020, Model C1030 Welded Tee Pipe Anchor Small Bore
C1000

1/4"

"D" DIA.
(4) HOLES

1/4"

4"
6"

Dimensions and ratings are subject to change without notice.


Available in all insulation thickness.
Note:



Pipe
Size
3
3.5
4
5
6

A
3
3.5
4
5
6

For no moment anchor, see: C1100


For insulated friction anchor, see: C3000
For large bore welded anchor, see: C2000
For insulated positive anchor, see: C4000

C
1.75
2.25
2.75
3.5
4.5

D
0.56
0.56
0.56
0.69
0.69

1"
B
4
4
4
4
4

2"
B
4
4
4
4
4

Insulation Thickness
3"
4"
5"
B
B
B
6
6
8
6
6
8
6
6
8
6
6
8
6
6
8

Application:

Features:

Material Data:

Model C1000 and C1030 are designed for use on:


Pipe Sizes through 6

Supplied with bolt holes for choice of bolting or


welding to support structure.

C1000: A36 Carbon Steel.

Model No.

Bottom-of-pipe to top-of-steel matches base


mounted insulated supports. See B Series.

For use with Pipe Material

C1000 Carbon Steel


C1010 Chrome-Moly
C1020
Carbon Silicon
C1030 Stainless

Broad selection of materials to match pipe


material and eliminate galvanic action.

6"
B
8
8
8
8
8

7"
B
10
10
10
10
10

C1010: A387 Gr. 22 Chrome-Moly Steel.


C1020: A515 Gr. 70 Carbon Silicon Steel.
C1030: 304L Stainless Steel.
Primer Coating: Primer coated or
hot dipped galvanized. Other coatings
available upon request.
Other materials available upon request.
Formal submittal sheets available.

74

www.pipeshields.com/c1000

Pipe
Shields
Inc.

Model C1100, Model C1110,


Model C1120, Model C1130 Welded C1100
Tee Pipe Anchor Small Bore

1/4"
B

1/4"
A

6"

Dimensions and ratings are subject to change without notice.


Available in all insulation thickness.
Note:



Pipe
Size
3
3.5
4
5
6

A
3
3.5
4
5
6

For welded anchor, see: C1000


For insulated friction anchor, see: C3000
For large bore welded anchor, see: C2100
For insulated positive anchor, see: C4000

1"
B
4
4
4
4
4

2"
B
4
4
4
4
4

Insulation Thickness
3"
4"
5"
B
B
B
6
6
8
6
6
8
6
6
8
6
6
8
6
6
8

Application:

Features:

Material Data:

Model C1100 and C1130 are designed for use on:


Pipe Sizes through 6

Supplied with bolt holes for choice of bolting or


welding to support structure.

C1100: A36 Carbon Steel.

Model No.

Bottom-of-pipe to top-of-steel matches base


mounted insulated supports. See B Series.

For use with Pipe Material

C1100 Carbon Steel


C1110 Chrome-Moly
C1120
Carbon Silicon
C1130 Stainless

Broad selection of materials to match pipe


material and eliminate galvanic action.

6"
B
8
8
8
8
8

7"
B
10
10
10
10
10

C1110: A387 Gr. 22 Chrome-Moly Steel.


C1120: A515 Gr. 70 Carbon Silicon Steel.
C1130: 304L Stainless Steel.
Primer Coating: Primer coated or
hot dipped galvanized. Other coatings
available upon request.
Other materials available upon request.
Formal submittal sheets available

www.pipeshields.com/c1100

75

Pipe
Shields
Inc.

Model C2000, Model C2010,


Model C2020, Model C2030 Welded Tee Pipe Anchor Large Bore
C2000

"D" DIA.
(4) HOLES

Dimensions and ratings are subject to change without notice. Contact us for current information.
Available in all insulation thickness.
Note:



Pipe
Size
8
10
12
14
16
18
20
24
30

A
6
6
6
6
6
9
9
9
12

C
4
4
4
4
4
6.5
6.5
6.5
9

For small bore welded tee anchor, see: C1000


For large bore no moment anchor , see: C2100
For insulated friction anchor, see: C3000
For insulated positive anchor, see: C4000

D
0.69
0.69
0.81
0.81
0.81
0.94
0.94
0.94
1.06

E
9
9
9
9
9
15
15
15
15

F
12
12
12
12
12
18
18
18
18

G
0.38
0.38
0.38
0.38
0.38
0.5
0.5
0.5
0.5

1"
B
4
4
4
4
4
4
4
4
4

2"
B
4
4
4
4
6
6
6
6
6

Insulation Thickness
3"
4"
5"
B
B
B
6
6
8
6
6
8
6
6
8
6
6
8
6
8
8
6
8
8
6
8
8
6
8
8
6
8
8

Application:

Features:

Material Data:

Model C2000 and C2030 are designed for use on:


Pipe Sizes through 8 through 30

Supplied with bolt holes for choice of bolting or


welding to support structure.

C2000: A36 Carbon Steel.

Model No.

Bottom-of-pipe to top-of-steel matches base


mounted insulated supports. See B Series.

For use with Pipe Material

C2000 Carbon Steel


C2010 Chrome-Moly
C2020
Carbon Silicon
C2030 Stainless

Broad selection of materials to match pipe


material and eliminate galvanic action.
Slots in central web for insulation banding.

6"
B
8
8
8
8
10
10
10
10
10

7"
B
10
10
10
10
10
10
10
10
10

C2010: A387 Gr. 23 Chrome-Moly Steel.


C2020: A515 Gr. 70 Carbon Silicon Steel.
C2030: 304L Stainless Steel.
Primer Coating: Primer coated or
hot dipped galvanized. Other coatings
available upon request.
Other materials available upon request.
Formal submittal sheets available

76

www.pipeshields.com/c2000

Pipe
Shields
Inc.

Model C2100, Model C2110,


Model C2120, Model C2130 Welded Tee Pipe Anchor Large Bore
C2100

G
A

Dimensions and ratings are subject to change without notice.


Available in all insulation thickness.
Note:



Pipe
Size
8
10
12
14
16
18
20
24
30

A
6
6
6
6
6
9
9
9
12

F
12
12
12
12
12
18
18
18
18

For welded anchor, see: C2000


For small bore welded teeno moment anchor, see: C1100
For insulated friction anchor, see: C3000
For insulated positive anchor, see: C4000

G
0.38
0.38
0.38
0.38
0.38
0.5
0.5
0.5
0.5

1"
B
4
4
4
4
4
4
4
4
4

2"
B
4
4
4
4
6
6
6
6
6

Insulation Thickness
3"
4"
5"
B
B
B
6
6
8
6
6
8
6
6
8
6
6
8
6
8
8
6
8
8
6
8
8
6
8
8
6
8
8

Application:

Features:

Material Data:

Model C2100 and C2130 are designed for use on:


Pipe Sizes through 8 through 30

Supplied with bolt holes for choice of bolting or


welding to support structure.

C2100: A36 Carbon Steel.

Model No.

Bottom-of-pipe to top-of-steel matches base


mounted insulated supports. See B Series.

For use with Pipe Material

C2100 Carbon Steel


C2110 Chrome-Moly
C2120
Carbon Silicon
C2130 Stainless

Broad selection of materials to match pipe


material and eliminate galvanic action.

6"
B
8
8
8
8
10
10
10
10
10

7"
B
10
10
10
10
10
10
10
10
10

C2110: A387 Gr. 11 Chrome-Moly Steel.


C2120: A515 Gr. 70 Carbon Silicon Steel.
C2130: 304L Stainless Steel.
Primer Coating: Primer coated or
hot dipped galvanized. Other coatings
available upon request.
Other materials available upon request.
Formal submittal sheets available

www.pipeshields.com/c2100

77

Pipe
Shields
Inc.

Model C3000 Insulated Friction Pipe Anchor

C3000

9"

6"

PIPE
B.O.P.
B

T.O.S.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: C3100, C4000.

Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Load Rating
Lat.
Vert.
Lbs
Lbs
140
70
88
175
113
225
163
325
375
188
460
230
265
530
420
840
525
1050
638
1275
850
1700
2000
1000
2200
1100
2500
1250
1450
2900
1600
3200
3400
1700
3600
1800
2350
4700
2750
5500
3100
6200

Axial
Lbs
28
35
45
65
75
92
106
168
210
255
340
400
440
500
580
640
680
720
940
1100
1240

Insul. Thk. = 1"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

C
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31

E
3.25
3.25
3.875
4.375
5
5.5
6.062
7.25
8.25
9.25
11.625
13.625
16.125
17.125
19.125
21.375
23.375
27.375
33.625
39.625
46.125

C
2
2
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5

E
4.375
4.375
4.875
5.5
6.0625
7.125
7.125
8.25
9.25
10.25
12.625
14.875
17.125
18.125
20.125
22.375
24.375
28.375
34.625
41.125
47.125

Insul. Thk. = 2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

C
2.5
2.5
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5

E
5.375
5.375
5.937
7
7
8.125
8.125
9.25
10.25
11.375
13.625
15.875
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125

Insul. Thk. = 2-1/2"


B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

C
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33

E
7
7
7
8
8
9.125
9.125
10.25
11.375
12.625
14.875
16.875
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125

Insul. Thk. = 3"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

C
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5

E
8
8
8
9
9.125
10.125
10.125
11.375
12.375
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125

Insul. Thk. = 4"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

C
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35

E
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
17.875
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125

Insul. Thk. = 5"


B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

C
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5

E
12.125
12.125
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125

Application:

Features:

Material Data:

Model C3000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Where thermal cycle are infrequent
Where axial forces are relatively light or in balance
Intended for installation on:
Flat Surfaces

All pipe sizes

C3000: Applicable PSI spec. doc.: No. 209


Insulation: Calcium Silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos-free, treated with water repellant
Steel Straps/Base: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped galvanized

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C3000U)

78

Insul. Thk. = 1-1/2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated
supports in B series
Performance test results on file:

Other coatings available upon request

Available upon request.

Formal submittal sheets available

www.pipeshields.com/c3000

Pipe
Shields
Inc.

Model C3100 Insulated Friction Pipe Anchor


C3000

9"

6"

PIPE
B.O.P.
B

T.O.S.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: C3200, C4100.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Load Rating
Lat.
Vert.
Lbs
Lbs
280
140
350
175
225
450
325
650
750
375
920
460
530
1060
840
1680
2100
1050
2550
1275
1700
3400
2000
4000
4400
2200
5000
2500
2900
5800
3200
6400
6800
3400
7200
3600
4700
9400
5500
11000
6200
12400

Axial
Lbs
56
70
90
130
150
184
212
336
420
510
680
800
880
1000
1160
1280
1360
1440
1880
2200
2480

Insul. Thk. = 1"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

C
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31

E
3.25
3.25
3.875
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125

Insul. Thk. = 1-1/2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

C
2
2
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5

E
4.375
4.375
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125

Insul. Thk. = 2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

C
2.5
2.5
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5

E
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125

Insul. Thk. = 2-1/2"


B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

C
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33

E
7
7
7
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125

Insul. Thk. = 3"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

C
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5

E
8
8
8
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125

Insul. Thk. = 4"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

C
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35

E
10
10
10
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125

Insul. Thk. = 5"


B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

C
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5

E
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125

Application:

Features:

Material Data:

Model C3100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Where thermal cycle are infrequent
Where axial forces are relatively light or in balance

All pipe sizes

C3100: Applicable PSI spec. doc.: No. 209.


Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos-free, treated with water repellant.
Steel Straps/Base: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.

Intended for installation on:


Flat surfaces

Temperature Range:

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated
supports in B series
Performance test results on file:

Other coatings available upon request.

Available upon request.

Formal submittal sheets available

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C3100U)

www.pipeshields.com/c3100

79

Pipe
Shields
Inc.

Model C3200 Insulated Friction Pipe Anchor


C3000

9"

6"

PIPE
B.O.P.
B

T.O.S.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: C3300, C4200.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Load Rating
Lat.
Vert.
Lbs
Lbs
400
200
500
250
325
650
475
950
1100
550
1350
675
800
1600
1250
2500
3100
1550
3800
1900
2550
5100
3000
6000
6600
3300
7500
3750
4350
8700
4800
9600
10200
5100
10800
5400
7050
14100
8250
16500
9300
18600

Axial
Lbs
80
100
130
190
220
270
320
500
620
760
1020
1200
1320
1500
1740
1920
2040
2160
2820
3300
3720

Insul. Thk. = 1"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

C
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31

E
3.25
3.25
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125

C
2
2
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5

E
4.375
4.375
5
5.5
6.1875
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125

Insul. Thk. = 2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

C
2.5
2.5
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5

E
5.375
5.375
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125

Insul. Thk. = 2-1/2"


B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

C
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33

E
7
7
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125

Insul. Thk. = 3"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

C
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5

E
8
8
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125

Insul. Thk. = 4"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

C
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35

E
10
10
10.125
11.25
11.25
12.25
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125

Insul. Thk. = 5"


B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

C
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5

E
12.125
12.25
12.25
13.25
13.25
14.5
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125

Application:

Features:

Material Data:

Model C3200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Where thermal cycle are infrequent
Where axial forces are relatively light or in balance

All pipe sizes

C3200: Applicable PSI spec. doc.: No. 209.


Insulation: Calcium Silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized Steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos-free, treated with water repellant.
Steel Straps/Base: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C3200U)

80

Insul. Thk. = 1-1/2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated
supports in B series
Performance test results on file:

Other coatings available upon request.

Available upon request.

Formal submittal sheets available

www.pipeshields.com/c3200

Pipe
Shields
Inc.

Model C3300 Insulated Friction Pipe Anchor


C3000

9"

6"

PIPE
B.O.P.
B

T.O.S.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: C4300.
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Load Rating
Lat.
Vert.
Lbs
Lbs
550
275
700
350
450
900
650
1300
1500
750
1800
900
1050
2100
1675
3350
4200
2100
5100
2550
3400
6800
4000
8000
8800
4400
10000
5000
5800
11600
6400
12800
13600
6800
14400
7200
9400
18800
11000
22000
12400
24800

Axial
Lbs
110
140
180
260
300
360
420
670
840
1020
1360
1600
1760
2000
2320
2560
2720
2880
3760
4400
4960

Insul. Thk. = 1"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

C
1.5
1.5
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31

E
3.375
3.375
4
4.5
5
5.5
6.187
7.25
8.5
9.5
11.625
13.875
16.125
17.125
19.375
21.375
23.375
27.375
33.625
40.125
46.125

Insul. Thk. = 1-1/2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

C
2
2
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5

E
4.5
4.5
5
5.5
6.0625
7.125
7.125
8.25
9.5
10.5
12.625
15.125
17.125
18.125
20.375
22.375
24.375
28.375
34.625
41.125
47.125

Insul. Thk. = 2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

C
2.5
2.5
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5

E
5.5
5.5
6.062
7.125
7.125
8.125
8.125
9.25
10.5
11.625
13.625
16.125
18.125
19.125
21.375
23.375
25.375
29.375
35.625
42.125
48.125

Insul. Thk. = 2-1/2"


B
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

C
4
4
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33

E
7.125
7.125
7.125
8.125
8.125
9.125
9.125
10.25
11.625
12.625
14.875
17.125
19.125
20.125
22.375
24.375
26.375
30.375
36.625
43.125
49.125

Insul. Thk. = 3"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

C
4.5
4.5
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5

E
8.125
8.125
8.125
9.125
9.125
10.125
10.125
11.375
12.625
13.625
15.875
18.125
20.125
21.125
23.375
25.375
27.375
31.375
37.625
44.125
50.125

Insul. Thk. = 4"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

C
6.5
6.5
6.5
7.5
7.5
8
8
9
9.5
10.5
12
13
14.5
15.5
16.5
18
19.5
22.5
26.5
31
35

E
10.125
10.125
10.125
11.25
11.25
12.375
12.375
13.375
14.875
15.875
18.125
20.125
22.125
23.125
25.375
27.375
29.375
33.375
39.625
46.125
52.125

Insul. Thk. = 5"


B
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

C
8
8
8
9
9
9.5
9.5
10.5
11
12
13
14.5
16
16.5
18
19.5
21
24
28
32.5
36.5

E
12.25
12.25
12.25
13.25
13.25
14.625
14.625
15.625
16.875
17.875
20.125
22.125
24.125
25.125
27.375
29.375
31.375
35.375
41.625
48.125
54.125

Application:

Features:

Material Data:

Model C3300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Where thermal cycle are infrequent
Where axial forces are relatively light or in balance

All pipe sizes

C3300: Applicable PSI spec. doc.: No. 209.


Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium silicate
asbestos-free, treated with water repellant.
Steel Straps/Base: Carbon Steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.

Intended for installation on:


Flat Surfaces

Temperature Range:

Easy installation
Eliminates welding to pipe
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated
supports in B series
Performance test results on file:

Other coatings available upon request.

Available upon request.

Formal submittal sheets available

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C3300U)

www.pipeshields.com/c3300

81

Pipe
Shields
Inc.

Model C4000, Model C4010,


Model C4020, Model C4030 Insulated Positive Pipe Anchor
C4000

7"
D

PIPE
B.O.P.
B

T.O.S.

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: C4100.
If thrust plate thickness D is greater than pipe wall thickness, consult factory.

Pipe
Size
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Load Rating
Vert.
Lat.
Lbs
Lbs
200
100
290
145
360
180
440
220
265
530
420
840
1050
525
1275
638
850
1700
2000 1000
2200 1100
2500 1250
2900 1450
3200 1600
3400 1700
3600 1800
4700 2350
5500 2750
6200 3100

Axial
Lbs B
410
4
590
4
730
4
890
4
1400 4
1730 4
2060 4
2400 4
3020 4
3700 4
4320 4
4700 4
5340 4
5970 4
6600 4
7850 4
9740 4
11600 4
13500 4

Insul. Thk. = 1"


C
2
2
2.5
2.5
3
4
4.5
5.5
7.5
9
10.5
11
12.5
14
15.5
18
22.5
26.5
31

D
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875
0.1875

E
4.125
4.625
5.125
5.625
6.187
7.25
8.25
9.25
11.375
13.625
15.625
16.625
18.625
20.625
22.625
26.625
33.125
39.125
45.125

C
2.5
2.5
3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5
16
19
23
27.5
31.5

D
0.1875
0.1875
0.1875
0.1875
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25

E
5.125
5.625
6.1875
7.25
7.25
8.25
9.25
10.25
12.375
14.875
16.875
17.875
19.875
21.875
23.875
27.875
34.125
40.125
46.125

Insul. Thk. = 2"


B
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6

C
3
4
4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5
16.5
19.5
24
28
32.5

D
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25

E
6.187
7.25
7.25
8.25
8.25
9.25
10.25
11.375
13.375
15.875
17.875
18.875
20.875
22.875
24.875
28.875
35.125
41.125
47.125

Insul. Thk. = 2-1/2"


B
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6

C
4
4.5
4.5
5.5
5.5
6.5
7.5
8
9.5
11
12.5
13
14.5
16
17.5
20.5
24.5
28.5
33

D
0.25
0.25
0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125

E
7.25
8.25
8.25
9.25
9.25
10.25
11.375
12.375
14.625
16.875
18.875
19.875
21.875
23.875
25.875
29.875
36.125
42.125
48.125

Insul. Thk. = 3"


B
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

C
4.5
5.5
5.5
6.5
6.5
7.5
8
9
10.5
12
13
14
15.5
16.5
18
21
25
29.5
33.5

D
0.25
0.25
0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125

E
8.25
9.25
9.25
10.25
10.25
11.375
12.375
13.375
15.625
17.875
19.875
20.875
22.875
24.875
26.875
30.875
37.125
43.125
49.125

Insul. Thk. = 4"


B
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8

C
D
E
6.5
0.25
10.25
7.5
0.25 11.375
7.5 0.3125 11.375
8 0.3125 12.375
8
0.375 12.375
9
0.375 13.375
9.5 0.375 14.625
10.5 0.375 15.625
12 0.375 17.625
13 0.375 19.875
14.5 0.375 21.875
15.5 0.375 22.875
16.5 0.375 24.875
18 0.375 26.875
19.5 0.375 28.875
22.5 0.375 32.875
26.5 0.375 39.125
31 0.375 45.125
35 0.375 51.125

Application:

Features:

Material Data:

Model C4000 through C4030 are designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Where large axial forces must be resisted

All pipe sizes

C4000 - C4030: specification document: No. 209.


Steel Inner Thrust Plates (supplied loose):

Intended for installation on:


Flat Surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C4000U)

82

Insul. Thk. = 1-1/2"


B
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6

Easy installation
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated
supports in B series
Performance test results on file:
Available upon request.

Model
C4000
C4010
C4020
C4030

ASTM
For Pipe Material
A36
Carbon Steel
A387GR.22 Chrome-Moly
A515GR.70
Carbon Silicon
A304L
Stainless Steel

Structural Inserts: High-density calcium silicate.


Asbestos-free, treated with water repellant.

Jackets: Galvanized Steel ASTM A-653.


Steel Straps & Base: Carbon Steel ASTM A-36
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request.
Fasteners: ASTM A-307 plated.

Formal submittal sheets available

www.pipeshields.com/c4000

Pipe
Shields
Inc.

Model C4100, Model C4110,


Model C4120, Model C4130 Insulated Positive Pipe Anchor
C4000

7"
D

PIPE
B.O.P.
B

T.O.S.

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: C4200.
If thrust plate thickness D is greater than pipe wall thickness, consult factory.

1
1 1/2

Load Rating
Vert.
Lat.
Lbs
Lbs
400
200
580
290

Axial
Lbs
640
930

B
4
4

C
2.5
2.5

D
0.25
0.25

E
5.375
5.875

B
4
4

C
3
4

D
0.25
0.25

E
6.437
7.5

B
4
4

C
4
4.5

2
2 1/2
3
4
5
6
8
10
12
14
16
18

720
870
1060
1680
2100
2550
3400
4000
4400
5000
5800
6400

360
435
530
840
1050
1275
1700
2000
2200
2500
2900
3200

1160
1410
2400
2900
3400
3900
4850
5850
6800
7350
8320
9240

4
4
4
4
4
4
4
4
4
4
4
4

3
4
4
4.5
5.5
6.5
8
9.5
11
12
13
14.5

0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125

6.4375
7.5
7.5
8.5
9.5
10.5
12.625
15.125
17.125
18.125
20.125
22.125

4
4
4
4
4
4
4
4
4
4
6
6

4
4.5
4.5
5.5
6.5
7.5
9
10.5
12
12.5
14
15.5

0.25
0.25
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125
0.3125

7.5
8.5
8.5
9.5
10.5
11.625
13.625
16.125
18.125
19.125
21.125
23.125

4
4
4
4
4
4
6
6
6
6
6
6

20
24
30
36
42

6800
7200
9400
11000
12400

3400
3600
4700
5500
6200

10200
12000
14900
17750
20500

4
4
6
6
6

16
19
23
27.5
31.5

0.3125
0.3125
0.3125
0.3125
0.3125

24.125
28.125
34.375
40.375
46.375

6
6
6
6
6

16.5
19.5
24
28
32.5

0.3125
0.3125
0.3125
0.3125
0.3125

25.125
29.125
35.375
41.375
47.375

6
6
6
6
6

Pipe
Size

Insul. Thk. = 1-1/2"

Insul. Thk. = 2"

Insul. Thk. = 2-1/2"


D
0.25
0.3125

Insul. Thk. = 3"


B
6
6

C
4.5
5.5

4.5 0.3125
8.5
5.5 0.3125
9.5
5.5 0.375
9.5
6.5 0.375
10.5
7.5 0.375 11.625
8
0.375 12.625
9.5 0.375 14.875
11
0.375 17.125
12.5 0.375 19.125
13 0.375 20.125
14.5 0.375 22.125
16 0.375 24.125

6
6
6
6
6
6
6
6
6
6
6
6

17.5
20.5
24.5
28.5
33

6
6
6
6
6

0.375
0.375
0.375
0.375
0.375

E
7.5
8.5

26.125
30.125
36.375
42.375
48.375

D
0.25
0.3125

Insul. Thk. = 4"


B
6
6

C
6.5
7.5

5.5 0.3125
9.5
6.5 0.3125 10.5
6.5 0.375
10.5
7.5 0.375 11.625
8
0.375 12.625
9
0.375 13.625
10.5 0.375 15.875
12 0.375 18.125
13 0.375 20.125
14 0.375 21.125
15.5 0.375 23.125
16.5 0.375 25.125

6
6
6
6
6
6
6
6
6
6
8
8

7.5 0.3125 11.625


8
0.375 12.625
8
0.5
12.625
9
0.5
13.625
9.5
0.5
14.875
10.5
0.5
15.875
12
0.5
17.875
13
0.5
20.125
14.5
0.5
22.125
15.5
0.5
23.125
16.5
0.5
25.125
18
0.5
27.125

18
21
25
29.5
33.5

8
8
8
8
8

19.5
22.5
26.5
31
35

0.375
0.375
0.375
0.375
0.375

E
8.5
9.5

27.125
31.125
37.375
43.375
49.375

D
E
0.3125 10.5
0.3125 11.625

0.5
0.5
0.5
0.5
0.5

29.125
33.125
39.375
45.375
51.375

Application:

Features:

Material Data:

Model C4100 through C4130 are designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Where large axial forces must be resisted

All pipe sizes

C4100 - C4130: specification document: No. 209.


Steel Inner Thrust Plates (supplied loose):

Intended for installation on:


Flat Surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C4100U)

www.pipeshields.com/c4100

Easy installation
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated

Model
C4100
C4110
C4120
C4130

ASTM
For Pipe Material
A36
Carbon Steel
A387GR.22 Chrome-Moly
A515GR.70
Carbon Silicon
A304L
Stainless Steel

supports in B series

Structural Inserts: High-density calcium silicate.

Performance test results on file:

Jackets: Galvanized Steel ASTM A-653.


Steel Straps & Base: Carbon Steel ASTM A-36
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dipped galvanized.

Available upon request.

Asbestos-free, treated with water repellant.

Other coatings available upon request.


Fasteners: ASTM A-307 plated.

Formal submittal sheets available

83

Pipe
Shields
Inc.

Model C4200, Model C4210,


Model
C4220, Model C4230 Insulated Positive Pipe Anchor
C4000
E

7"
D

PIPE
B.O.P.
B

T.O.S.

4"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load ratings, see: C4300.
If thrust plate thickness D is greater than pipe wall thickness, consult factory.

1
1 1/2

Load Rating
Vert.
Lat.
Lbs
Lbs
600
300
870
435

Axial
Lbs
900
1290

B
4
4

C
3
4

D
0.3125
0.3125

E
6.687
7.75

B
4
4

C
4
4.5

D
0.3125
0.3125

E
7.75
8.75

B
6
6

C
4.5
5.5

D
0.3125
0.375

E
8.75
9.75

B
6
6

C
6.5
7.5

D
0.3125
0.375

E
10.75
11.875

2
2 1/2
3
4

1090
1310
1600
2500

545
655
800
1250

1620
1960
3450
4100

4
4
4
4

4
4.5
4.5
5.5

0.3125
0.3125
0.375
0.375

7.75
8.75
8.75
9.75

4
4
4
4

4.5
5.5
5.5
6.5

0.3125
0.375
0.5
0.5

8.75
9.75
9.75
10.75

6
6
6
6

5.5
6.5
6.5
7.5

0.375
0.375
0.5
0.5

9.75
10.75
10.75
11.875

6
6
6
6

7.5
8
8
9

0.375
0.375
0.5
0.5

11.875
12.875
12.875
13.875

5
6
8
10
12
14
16
18

3100
3800
5100
6000
6600
7500
8700
9600

1550
1900
2550
3000
3300
3750
4350
4800

4750
5400
6675
8000
9300
10000
11300
12500

4
4
4
4
4
4
6
6

6.5
7.5
9
10.5
12
12.5
14
15.5

0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375

10.75
11.875
13.875
16.375
18.375
19.375
21.375
23.375

4
4
6
6
6
6
6
6

7.5
8
9.5
11
12.5
13
14.5
16

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

11.875
12.875
15.125
17.375
19.375
20.375
22.375
24.375

6
6
6
6
6
6
6
6

8
9
10.5
12
13
14
15.5
16.5

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

12.875
13.875
16.125
18.375
20.375
21.375
23.375
25.375

6
6
6
6
6
6
8
8

9.5
10.5
12
13
14.5
15.5
16.5
18

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

15.125
16.125
18.125
20.375
22.375
23.375
25.375
27.375

20
24
30
36
42

10200
10800
14100
16500
16500

5100
5400
7050
8250
8250

13800
16300
20100
23900
23900

6
6
6
6
6

16.5
19.5
24
28
32.5

0.375
0.375
0.375
0.375
0.375

25.375
29.375
35.625
41.625
47.625

6
6
6
6
6

17.5
20.5
24.5
28.5
33

0.5
0.5
0.5
0.5
0.5

26.375
30.375
36.625
42.625
48.625

6
6
6
6
6

18
21
25
29.5
33.5

0.5
0.5
0.5
0.5
0.5

27.375
31.375
37.625
43.625
49.625

8
8
8
8
8

19.5
22.5
26.5
31
35

0.5
0.5
0.5
0.5
0.5

29.375
33.375
39.625
45.625
51.625

Pipe
Size

Insul. Thk. = 2-1/2"

Insul. Thk. = 3"

Insul. Thk. = 4"

Application:

Features:

Material Data:

Model C4200 through C4230 are designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Where large axial forces must be resisted

All pipe sizes

C4200 - C4230: specification document: No. 209.


Steel Inner Thrust Plates (supplied loose):

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C4200U)

84

Insul. Thk. = 2"

Easy installation
Overlapping galvanized sheet metal jacket
Positive stop - axial, lateral, vertical
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated
supports in B series
Performance test results on file:
Available upon request.

Model
C4200
C4210
C4220
C4230

ASTM
For Pipe Material
A36
Carbon Steel
A387GR.22 Chrome-Moly
A515GR.70
Carbon Silicon
A304L
Stainless Steel

Structural Inserts: High-density calcium silicate.


Asbestos-free, treated with water repellant.

Jackets: Galvanized steel ASTM A-653.


Steel Straps & Base: Carbon steel ASTM A-36
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request.
Fasteners: ASTM A-307 plated.

Formal submittal sheets available

www.pipeshields.com/c4200

Pipe
Shields
Inc.

Model C4300, Model C4310,


Model C4320, Model C4330 Insulated Positive Pipe Anchor
C4300

9"

E
D

PIPE
B.O.P.
B

T.O.S.

6"

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.
The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.
Dimensions and ratings are subject to change without notice.
Note: For higher load rating contact factory - If thrust plate thickness D is greater than pipe wall thickness, consult factory.
Load Rating
Vert.
Lat.
Axial
Lbs
Lbs
Lbs
910
455
1360
1310
655
1970
1640
820
2460
1980
990
2980
2420 1210
3620
3110 1555
4660

B
4
4
4
4
4
4

C
4
4.5
4.5
5.5
5.5
6.5

D
0.375
0.5
0.5
0.5
0.5
0.5

E
8
9
9
10
10
11

B
6
6
6
6
6
6

C
4.5
5.5
5.5
6.5
6.5
7.5

D
0.5
0.5
0.5
0.5
0.5
0.5

E
9
10
10
11
11
12.125

B
6
6
6
6
6
6

C
6.5
7.5
7.5
8
8
9

D
0.5
0.5
0.5
0.625
0.625
0.625

E
11
12.125
12.125
13.125
13.125
14.125

5
6
8
10

3840
4570
5950
7420

1920
2285
2975
3710

5760
6860
8930
11130

4
4
6
6

7.5
8
9.5
11

0.5
0.5
0.5
0.5

12.125
13.125
15.375
17.375

6
6
6
6

8
9
10.5
12

0.5
0.625
0.625
0.625

13.125
14.125
16.375
18.375

6
6
6
6

9.5
10.5
12
13

0.625
0.625
0.625
0.625

15.375
16.375
18.375
20.375

12
14
16
18

8800
10000
11600
12800

4400
5000
5800
6400

13200
15000
17400
19200

6
6
6
6

12.5
13
14.5
16

0.5
0.5
0.5
0.5

19.625
20.625
22.625
24.625

6
6
6
6

13
14
15.5
16.5

0.625
0.625
0.625
0.625

20.625
21.625
23.625
25.625

6
6
8
8

14.5
15.5
16.5
18

0.625
0.625
0.625
0.625

22.625
23.625
25.625
27.625

20
24
30
36
42

13600 6800
14400 7200
18800 9400
22000 11000
24800 12400

20400
21600
28200
33000
37200

6
6
6
6
6

17.5
20.5
24.5
28.5
33

0.5
0.5
0.5
0.5
0.5

26.625
30.625
37.125
43.125
49.125

6
6
6
6
6

18
21
25
29.5
33.5

0.625
0.625
0.625
0.625
0.625

27.625
31.625
38.125
44.125
50.125

8
8
8
8
8

19.5
22.5
26.5
31
35

0.625
0.625
0.625
0.625
0.625

29.625
33.625
40.125
46.125
52.125

Pipe
Size
1
1 1/2
2
2 1/2
3
4

Insul. Thk. = 2-1/2"

Insul. Thk. = 3"

Insul. Thk. = 4"

Application:

Features:

Material Data:

Model C4300 through C4330 are designed for


use on:
Hot Water
Steam
Cold Water
Air
Chilled Water
Gas
Dual Temperature
Vacuum
Where large axial forces must be resisted

All pipe sizes

C4300 - C4330: specification document: No. 209.


Steel Inner Thrust Plates (supplied loose):

Intended for installation on:


Flat surfaces

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., C4300U)

www.pipeshields.com/c4300

Easy Installation
Overlapping galvanized sheet metal jacket
Positive stop - axial, lateral, vertical
Other I.D.s and/or O.D.s available on request
Bottom-of-pipe to top-of-shield matches insulated
supports in B series
Performance test results on file:
Available upon request.

Model
ASTM
For Pipe Material
C4300
A36
Carbon Steel
C4310 A387GR.11 Chrome-Moly
C4320
A515GR.70
Carbon Silicon
C4330
A304L
Stainless Steel

Structural Inserts: High-density calcium silicate.


Asbestos-free, treated with water repellant.

Jackets: Galvanized Steel ASTM A-653.


Steel Straps & Base: Carbon Steel ASTM A-36
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request.
Fasteners: ASTM A-307 plated.

Formal Submittal Sheets available

85

Pipe
Shields
Inc.

Introduction: Section D

INTRODUCTION
SECTION D
PRE-INSULATED PIPE SUPPORTS Hanger Type
APPLICATION Heavy Industrial and Large HVAC Distribution Systems
Note: These supports were designed to take advantage of maximum hanger spacings and/or
to accommodate thermal loads or loads due to the presence of valves or other pipe systems
components.
Models D1000 D2000

Two-bolt hanger insulated supports for up to 4 pipe size.

Models D3000 D3300

Two-bolt hanger insulated supports for 1 through 42 pipe size.

Models D4000 D5000

Double-rod hung insulated supports for up to 4 pipe size. Designed to


accommodate minimum overhead clearance conditions.

Models D6000 D6300

Double-rod insulated supports for 5 through 30 pipe size. Designed to


accommodate minimum overhead clearance conditions.

By modifying our standard pipe support concept with combinations of structural insert materials and
strap design, we can readily and economically respond to virtually any pipe support requirement.
If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at
707-447-5014 or 1-800-538-7007.

Please acquaint yourself with the selection guide at the front of this catalog and the section index on
the page following this introduction, for assistance in determining the most appropriate support for your
application.

86

Pipe
Shields
Inc.

Section D Index
PRE-INSULATED PIPE SUPPORTS

HANGER TYPE

D1000, D3000

D4000, D6000

PRIMARY
APPLICATION
HOT
COLD

MODEL

PIPE
SIZE
RANGE

D1000
D2000
D3000
D3100
D3200
D3300

1/2 - 4
1/2 - 4
1 - 42
1 - 42
1 - 42
1 - 42

D4000
D5000
D6000
D6100
D6200
D6300

1/2 - 4
1/2 - 4
5 - 30
5 - 30
16 - 30
20 - 30

X
X
X
X
X

X
X
X
X

SPECIAL
FEATURES

2 - BOLT
2 - BOLT
2 - BOLT
2 - BOLT
2 - BOLT
2 - BOLT

MIN. OVERHEAD
CLEARANCE

X
X
X
X
X

X
X
X
X

"
"
"
"
"

DUTY

HEAVY
HEAVY
HEAVY
EXTRA-HEAVY

HEAVIER
HEAVIEST

HEAVY
HEAVY
HEAVY
EXTRA-HEAVY

HEAVIER
HEAVIEST

TO ORDER, specify:
1. Quantity 20
2. Pipe Size & Type
2 IPS
3. Insulation Thickness
3
4. Model Number
D1000
EXAMPLE:

www.pipeshields.com/d-series

(20) 2

D1000

87

Pipe
Shields
Inc.

D1000, D3000

Model D1000 Insulated 2-Bolt Hanger

BEAD
(TYP.)
A

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.

Iron
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4

Vert

load
lbs.
65
75
90
150
245
290
365
475

A
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2

B
0.38
0.38
0.38
0.38
0.50
0.50
0.63
0.63

C
0.69
0.69
0.69
0.69
0.81
0.81
1.06
1.06

Insul.
Thk. 1"
D
E
F
0.56 2.38
4
0.56 2.38
4
0.56 2.69
4
0.56 2.94
4
6
0.63 3.56
0.63 3.81
6
0.63 4.22
6
0.63 4.75
6
TABLE I

Insul.
Thk. 3"
E
F
4.75
6
4.75
6
4.75
6
5.25
6
5.63
6
6.13
9
6.25
9
6.81
9

Insul.
Thk. 4"
E
F
5.75
6
5.75
6
5.75
6
6.31
6
6.69
6
7.19
9
7.31
9
7.81
9

Insul.
Thk. 5"
E
F
6.81
6
6.81
6
6.81
6
7.31
6
7.69
6
8.31
9
8.44
9
8.94
9

Application:

Features:

Material Data:

Model D1000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D1000: Applicable PSI specification document:


No. 209.
Insulation: Calcium Silicate Asbestos-free,
treated with water repellant.
Jackets: Galvanized Steel ASTM A-653.
Steel Straps: Carbon Steel ASTM A-36
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request.

Intended to be hung from threaded rod.

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat loss and/or condensation
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D1000U)

88

Insul.
Thk. 2"
E
F
3.44
4
3.44
4
3.72
4
4.25
4
4.63
6
5.13
6
5.25
6
5.75
6

Fasteners: ASTM A-307 plated.


Performance test results on file:

Formal submittal sheets available

Available upon request.

www.pipeshields.com/d1000

Pipe
Shields
Inc.

Model D2000 Insulated 2-Bolt Hanger


D2000

1"

BEAD
(TYP.)

(TYP.)

A
E

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.

Iron
Pipe
Size
1/2
3/4
1
1 1/2
2
2 1/2
3
4

Vert
load
lbs.
65
75
90
150
245
290
365
475

A
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/8x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2
1/4x 1 1/2

B
0.38
0.38
0.38
0.38
0.50
0.50
0.63
0.63

C
0.69
0.69
0.69
0.69
0.81
0.81
1.06
1.06

Insul.
Thk. 1"
D
E
F
0.56 2.38
6
0.56 2.38
6
0.56 2.69
6
0.56 2.94
6
0.63 3.56
6
0.63 3.81
6
0.63 4.22
6
0.63 4.75
6
TABLE I

Insul.
Thk. 2"
E
F
3.44
6
3.44
6
3.72
6
4.25
6
4.63
6
5.13
6
5.25
6
5.75
6

Insul.
Thk. 3"
E
F
4.75
6
4.75
6
4.75
6
5.25
6
5.63
6
6.13
9
6.25
9
6.81
9

Insul.
Thk. 4"
E
F
5.75
6
5.75
6
5.75
6
6.31
6
6.69
6
7.19
9
7.31
9
7.81
9

Insul.
Thk. 5"
E
F
6.81
6
6.81
6
6.81
6
7.31
6
7.69
6
8.31
9
8.44
9
8.94
9

Application:

Features:

Material Data:

D2000 is designed for use on:


Cold water
Chilled water

Compact

D2000: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate Asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Steel Straps: Carbon steel ASTM A-36
Glue: Industrial contact adhesive.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request.

Intended to be hung from threaded rod

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D2000U)

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat loss and/or condensation
Other I.D.s and/or O.D.s available on request
Calcium silicate insulation extend 1 beyond the
galvanized sheet metal jacket providing for an

Fasteners: ASTM A-307 plated.


Formal submittal sheets available

easier wet lag butt joint with the pipe insulation.


Performance test results on file:
Available upon request.

www.pipeshields.com/d2000

89

Pipe
Shields
Inc.

Model D3000 Insulated 2-Bolt Hanger

D1000, D3000

BEAD
(TYP.)
A

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load ratings, see: D3100.
Pipe
Size

Vert
load
lbs.

Insul.
Thk. 1"
E
F

285

3/16x2

0.375

0.675

0.75

2.81

1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

320
320
540
540
770
1125
1430
1805
2310
2705
2705
3035
3750
3855
4935
5295
7855
7970

3/16x2
3/16x2
1/4x2
1/4x2
1/4x3
3/8x3
3/8x3
1/2x3
1/2x3
5/8x3
5/8x3
5/8x3
3/4x3
3/4x3
1x3
1x3
1x6
1x6

0.375
0.375
0.375
0.375
0.5
0.5
0.625
0.625
0.75
0.75
0.75
0.875
0.875
1
1
1.25
1.25
1.25

0.675
0.675
0.675
0.675
0.84
0.84
1.05
1.05
1.05
1.05
1.05
1.315
1.315
1.315
1.315
1.66
1.66
1.66

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1
1
1.25
1.25
1.25

3.06
6
3.31
6
3.69
6
3.97
6
4.63
6
5.38
6
6
6
7.31
6
8.44
6
9.69
6
10.19
6
11.31
6
12.56
6
13.69
6
16.19
6
19.44
6
22.44
9
25.44
9
TABLE I

Insul.
Thk. 2"
E
F

Insul.
Thk. 4"
E
F

Insul.
Thk. 5"
E
F

3.84

4.88

5.88

6.94

4.38
4.38
5
5
5.63
6.38
7.06
8.31
9.56
10.69
11.19
12.31
13.56
14.69
17.19
20.44
23.44
26.44

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9

5.38
5.38
6
6
6.69
7.44
8.06
9.44
10.56
11.69
12.18
13.31
14.56
15.69
18.19
21.44
24.44
27.44

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9

6.44
6.44
7.06
7.06
7.69
8.56
9.18
10.44
11.56
12.69
13.19
14.31
15.56
16.69
19.18
22.44
25.44
28.44

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9

7.44
7.44
8.19
8.19
8.81
9.56
10.19
11.44
12.56
13.69
14.19
15.31
16.56
17.69
20.19
23.44
26.44
29.44

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
9
9

Application:

Features:

Material Data:

D3000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D3000: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request
Formal submittal sheets available

Intended to be hung from threaded rod.

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat loss and/or condensation
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D3000U)

90

Insul.
Thk. 3"
E
F

Performance test results on file:


Available upon request.

www.pipeshields.com/d3000

Pipe
Shields
Inc.

D1000, D3000

Model D3100 Insulated 2-Bolt Hanger

BEAD
(TYP.)
A

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load ratings, see: D3200.
Pipe
Size
1
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

Vert
load
lbs.
510
605
605
810
1125
1720
2340
2705
3605
3630
4660
4660
6820
6820
7970
10285
10600
13020
13020

A
3/16x3
1/4x3
1/4x3
1/4x3
3/8x3
3/8x3
1/2x3
1/2x3
5/8x3
5/8x3
3/4x3
3/4x3
3/4x5
3/4x5
1x6
1x6
1x6
1 1/4x6
1 1/4x6

B
0.375
0.375
0.375
0.5
0.5
0.625
0.75
0.75
0.875
0.875
1
1
1.25
1.25
1.25
1.5
1.5
2
2

C
0.675
0.675
0.675
0.84
0.84
1.05
1.05
1.05
1.315
1.315
1.315
1.315
1.66
1.66
1.66
1.9
1.9
2.375
2.375

D
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1
1
1.25
1.25
1.25
1.25
1.25
1.75
1.75

Insul.
Thk. 1"
E
F
2.81
6
3.19
6
3.44
6
3.81
6
4.34
6
5
6
5.88
6
6.38
6
7.69
6
8.69
6
10.19
6
10.69
6
11.94
9
12.94
9
14.44
9
16.69
9
19.69
9
23.69
9
26.69
9
TABLE I

Insul.
Thk. 2"
E
F
3.84
6
4.5
6
4.5
6
5.13
6
5.38
6
6
6
6.88
6
7.44
6
8.69
6
9.81
6
11.19
6
11.69
6
12.94
9
13.94
9
15.44
9
17.69
9
20.69
9
24.69
9
27.69
9

Insul.
Thk. 3"
E
F
4.88
6
5.5
6
5.5
6
6.13
6
6.38
6
7.06
6
7.94
6
8.44
6
9.81
6
10.81
6
12.19
6
12.69
6
13.94
9
14.94
9
16.44
9
18.69
9
21.69
9
25.69
9
28.69
9

Insul.
Thk. 4"
E
F
5.88
6
6.56
6
6.56
6
7.19
6
7.44
6
8.06
6
9.06
6
9.56
6
10.81
6
11.81
6
13.19
6
13.69
6
14.94
9
15.94
9
17.44
9
19.69
9
22.69
9
26.69
9
29.69
9

Insul.
Thk. 5"
E
F
6.94
6
7.56
6
7.56
6
8.31
6
8.56
6
9.19
6
10.06
6
10.56
6
11.81
6
12.81
6
14.19
6
14.69
6
15.94
9
16.94
9
18.44
9
20.69
9
23.69
9
27.69
9
30.69
9

Application:

Features:

Material Data:

D3100 is designed for use on:


Hot Water
Steam
Cold Water
Air
Chilled Water
Gas
Dual Temperature
Vacuum

Compact

D3100: Applicable PSI specification document:


No. 209
Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant
Steel Straps: Carbon steel ASTM A-36
Fasteners: ASTM A-307 plated
Coating: Primer coated or hot dipped galvanized
Other coatings available upon reques

Intended to be hung from threaded rod

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D3100U)

Performance test results on file:


Available upon request.

Formal submittal sheets available

www.pipeshields.com/d3100

91

Pipe
Shields
Inc.

D1000, D3000

Model D3200 Insulated 2-Bolt Hanger


D

BEAD
(TYP.)
A

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load ratings, see: D3300.
Pipe
Size

Vert
load
lbs.

Insul.
Thk. 1"
E
F

850

1/4x4 1/2

0.625

1.05

0.75

3.19

1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

1215
1215
1215
1805
2585
2705
3750
4215
6045
7770
7770
7970
11270
11465
12220
16480
17370
17370

1/4x4 1/2
1/4x4 1/2
1/4x4 1/2
3/8x4 1/2
3/8x4 1/2
1/2x4 1/2
1/2x4 1/2
1/2x5
5/8x5
3/4x5
3/4x5
1x5
1x5
1x6
1x6
1 1/4x6
1 1/4x8
1 1/4x8

0.625
0.625
0.625
0.625
0.75
0.75
0.875
1
1.25
1.25
1.25
1.25
1.5
1.5
2
2
2
2

1.05
1.05
1.05
1.05
1.05
1.05
1.315
1.315
1.66
1.66
1.66
1.66
1.9
1.9
2.375
2.375
2.375
2.375

0.75
0.75
0.75
0.75
0.75
0.75
1
1
1.25
1.25
1.25
1.25
1.25
1.25
1.75
1.75
1.75
1.75

3.44
9
3.69
9
3.94
9
4.47
9
5.13
9
5.88
9
6.5
9
7.81
9
9.06
9
10.44
9
10.94
9
12.44
9
13.69
9
14.69
9
17.06
9
20.69
9
23.69
12
26.69
12
TABLE I

Insul.
Thk. 2"
E
F

Insul.
Thk. 3"
E
F

Insul.
Thk. 4"
E
F

Insul.
Thk. 5"
E
F

4.22

5.25

6.25

7.31

4.75
4.75
5.25
5.5
6.13
6.88
7.56
8.81
10.19
11.44
11.94
13.44
14.69
15.69
18.06
21.69
24.69
27.69

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12

5.75
5.75
6.25
6.5
7.19
7.94
8.56
9.94
11.19
12.44
12.94
14.44
15.69
16.69
19.06
22.69
25.69
28.69

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12

6.81
6.81
7.31
7.56
8.19
9.06
9.69
10.94
12.19
13.44
13.94
15.44
16.69
17.69
20.06
23.69
26.69
29.69

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12

7.81
7.81
8.44
8.69
9.31
10.06
10.69
11.94
13.19
14.44
14.94
16.44
17.69
18.69
21.06
24.69
27.69
30.69

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12

Application:

Features:

Material Data:

D3200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D3200: Applicable PSI specification document:


No. 209
Insulation: Calcium silicate asbestos-free,
treated with water repellant
Jackets: Galvanized steel ASTM A-653
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request

Intended to be hung from threaded rod

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D3200U)

Performance Test Results on File:


Available upon request.

Formal submittal sheets available

92

www.pipeshields.com/d3200

Pipe
Shields
Inc.

D1000, D3000

Model D3300 Insulated 2-Bolt Hanger

BEAD
(TYP.)
A

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Note: For higher load ratings contact factory. Contact factory for current inform ation.

Pipe
Size

Vert
load
lbs.

Insul.
Thk. 1"
E
F

1135

1/4x6

0.625

1.05

0.75

3.188

1.5
2
2.5
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42

1630
1715
1805
2705
3445
3750
4935
7215
7257
9320
9320
11465
14445
16580
19005
20605
24905
24905

1/4x6
1/4x6
3/8x6
3/8x6
3/8x6
1/2x6
1/2x6
5/8x6
5/8x6
3/4x6
3/4x6
1x6
1x6
1 1/4x6
1 1/4x6
1 1/4x8
1 1/2x8
1 1/2x8

0.625
0.625
0.625
0.75
0.875
0.875
1
1.25
1.25
1.5
1.5
1.5
2
2
2
2
2.5
2.5

1.05
1.05
1.05
1.05
1.315
1.315
1.315
1.66
1.66
1.9
1.9
1.9
2.375
2.375
2.375
2.375
3.508
3.508

0.75
0.75
0.75
0.75
1
1
1
1.25
1.25
1.25
1.25
1.25
1.75
1.75
1.75
1.75
1.75
1.75

3.44
9
3.69
9
4.19
9
4.59
9
5.25
9
6
9
6.75
9
8.06
9
9.06
9
10.69
9
11.19
9
12.69
9
14.06
9
15.69
9
17.69
9
20.69
12
24.44
12
27.44
12
TABLE I

Insul.
Thk. 2"
E
F

Insul.
Thk. 3"
E
F

Insul.
Thk. 4"
E
F

Insul.
Thk. 5"
E
F

4.22

5.25

6.25

7.31

4.75
4.75
5.5
5.63
6.25
7
7.81
9.06
10.19
11.69
12.19
13.69
15.06
16.69
18.69
21.69
25.44
28.44

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12

5.75
5.75
6.5
6.63
7.31
8.06
8.81
10.19
11.19
12.69
13.19
14.69
16.06
17.69
19.69
22.69
26.44
29.44

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12

6.81
6.81
7.56
7.69
8.31
9.19
9.94
11.19
12.19
13.69
14.19
15.69
17.06
18.69
20.69
23.69
27.44
30.44

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12

7.81
7.81
8.69
8.81
9.44
10.19
10.94
12.19
13.19
14.69
15.19
16.69
18.06
19.69
21.69
24.69
28.44
31.44

9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
12
12
12

Application:

Features:

Material Data:

D3300 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D3300: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request
Formal submittal sheets available

Intended to be hung from threaded rod

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D3300U)

www.pipeshields.com/d3300

Performance test results on file:


Available upon request.

93

Pipe
Shields
Inc.

D4000, D6000

Model D4000 Insulated 2-Rod Hanger

THREADED ROD
(BY OTHERS)

BEAD
(TYP.)

1/4" THK.
TOP STRAP
C

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are subject
to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load rating contact factory

Pipe
Size

Vert
load
lbs.

1/2
3/4
1
1 1/2
2
2 1/2
3
4

65
75(a)
90
130
245
290
365
475

Insul.
Thk. 1"
D

1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2

0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375

1.63
1.63
1.94
2.19
2.44
2.69
2.97
3.5

4.75
4.75
5.375
5.875
6.875
7.375
7.937
9

6
6
6
6
6
6
6
6

2.69 6.875
2.69 6.875
2.97 7.437
3.50
8.5
3.50
9
4.0
10
4.0
10
4.5
11
TABLE I

Insul.
Thk. 3"
D

6
6
6
6
6
6
6
6

4.0
4.0
4.0
4.5
4.5
5.0
5.0
5.56

9.5
9.5
9.5
10.5
11
12
12
13.125

E
6
6
6
6
6
9
9
9

Insul.
Thk. 4"
D

5.0
5.0
5.0
5.56
5.56
6.06
6.06
6.56

11.5
11.5
11.5
12.625
13.125
14.125
14.125
15.125

6
6
6
6
6
9
9
9

Application:

Features:

Material Data:

D4000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D4000: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request
Formal submittal sheets available

Intended to be hung from two threaded rods in


close overhead clearance conditions.

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D4000U)

94

Insul.
Thk. 2"
D

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Other I.D.s and/or O.D.s available on request

Performance test results on file:


Available upon request.

www.pipeshields.com/d4000

Pipe
Shields
Inc.

D5000
Model D5000 Insulated 2-Rod
Hanger

THREADED ROD
(BY OTHERS)
1"

BEAD
(TYP.)

(TYP.)
B

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load rating contact factory

Pipe
Size

Vert
load
lbs.

1/2
3/4
1
1 1/2
2
2 1/2
3
4

65
75
90
130
245
290
365
475

1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/8x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2
1/4x1 1/2

0.375
0.375
0.375
0.375
0.375
0.375
0.375
0.375

Insul.
Thk. 1"
D

Insul.
Thk. 2"
D

1.63
1.63
1.94
2.19
2.44
2.69
2.97
3.5

4.75
4.75
5.375
5.875
6.875
7.375
7.937
9

6
6
6
6
6
6
6
6

2.69
2.69
2.97
3.50
3.50
4.0
4.0
4.5
TABLE I

6.875
6.875
7.437
8.5
9
10
10
11

Insul.
Thk. 3"
D

6
6
6
6
6
6
6
6

4.0
4.0
4.0
4.5
4.5
5.0
5.0
5.56

9.5
9.5
9.5
10.5
11
12
12
13.125

E
6
6
6
6
6
9
9
9

Insul.
Thk. 4"
D

5.0
5.0
5.0
5.56
5.56
6.06
6.06
6.56

11.5
11.5
11.5
12.625
13.125
14.125
14.125
15.125

6
6
6
6
6
9
9
9

Application:

Features:

Material Data:

D5000 is designed for use on:


Cold water
Chilled water

Compact

D5000: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request
Formal submittal sheets available

Intended to be hung from two threaded rods in


close overhead clearance conditions.

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D5000U)

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Minimal overhead clearance requirement
Other I.D.s and/or O.D.s available on request

Performance test results on file:


Available upon request.

www.pipeshields.com/d5000

95

Pipe
Shields
Inc.

D4000, D6000

Model D6000 Insulated 2-Rod Hanger

THREADED ROD
(BY OTHERS)

BEAD
(TYP.)

1/4" THK.
TOP STRAP
C

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load ratings, see: D6100.
Pipe
Size

Vert
load
lbs.

5
6
8
10
12
14
16
18
20
24
30

600
800
1300
2000
2400
2500
3300
3500
3600
4500
4800

1/2x3
1/2x3
1/2x3
1/2x3
5/8x3
5/8x3
3/4x3
3/4x3
3/4x3
1x3
1x3

0.375
0.375
0.500
0.500
0.625
0.625
0.750
0.750
0.750
0.750
0.750

Insul.
Thk. 1"
D

4.13
4.63
5.68
6.69
7.81
8.31
9.31
10.31
11.31
13.31
16.31

11
12
14.375
16.375
19.375
20.375
22.875
24.875
26.875
31.625
37.625

6
6
6
6
6
6
6
9
9
9
12

5.13
5.68
6.68
7.81
8.81
9.31
10.31
11.31
12.31
14.31
17.31
TABLE

Insul.
Thk. 2"
D

13
14.125
16.375
18.625
21.375
22.375
24.875
26.875
28.875
33.625
39.625

6
6
6
6
6
6
9
9
9
12
12

Insul.
Thk. 3"
D

6.18
6.68
7.81
8.81
9.81
10.31
11.31
12.31
13.31
15.31
18.31

15.125
16.125
18.625
20.625
23.375
24.375
26.875
28.875
30.875
35.625
41.625

6
6
6
6
6
9
9
9
9
12
12

C
7.31
7.81
8.81
9.81
10.81
11.31
12.31
13.31
14.31
16.31
19.31

Insul.
Thk. 4"
D

17.375
18.375
20.625
22.625
25.375
26.375
28.875
30.875
32.875
37.625
43.625

6
6
6
9
9
9
9
12
12
12
12

Application:

Features:

Material Data:

D6000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D6000: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request

Intended to be hung from two threaded rods in


close overhead clearance conditions.

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Minimal overhead clearance requirement
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D6000U)

Performance test results on file:


Available upon request.

Formal submittal sheets available

96

www.pipeshields.com/d6000

Pipe
Shields
Inc.

D4000, D6000

Model D6100 Insulated 2-Rod Hanger

THREADED ROD
(BY OTHERS)

BEAD
(TYP.)

1/4" THK.
TOP STRAP
C

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load ratings, see: D6200.
Pipe
Size
5
6
8
10
12
14
16
18
20
24
30

Vert
load
lbs.
1200
1600
2600
4000
4800
5000
6150
6150
6150
8550
8550

A
1/2x3
1/2x3
1/2x3
5/8x3
3/4x3
3/4x3
1x3
1x4 1/2
1x4 1/2
1x4 1/2
1x4 1/2

B
0.50
0.50
0.63
0.75
0.75
0.75
0.88
0.88
0.88
1.00
1.25

C
4.13
4.63
5.68
6.69
7.81
8.31
9.31
10.31
11.31
13.31
16.31

Insul.
Thk. 1"
D
11.25
12.25
14.625
17.125
19.875
20.875
24.125
26.125
28.125
32.375
38.875

E
6
6
6
6
6
6
6
9
9
9
12

C
5.13
5.68
6.68
7.81
8.81
9.31
10.31
11.31
12.31
14.31
17.31
TABLE I

Insul.
Thk. 2"
D
13.25
14.375
16.625
19.375
21.875
22.875
26.125
28.125
30.125
34.375
40.875

E
6
6
6
6
6
6
9
9
9
12
12

C
6.18
6.68
7.81
8.81
9.81
10.31
11.31
12.31
13.31
15.31
18.31

Insul.
Thk. 3"
D
15.375
16.375
18.875
21.375
23.875
24.875
28.125
30.125
32.125
36.375
42.875

E
6
6
6
6
6
9
9
9
9
12
12

C
7.31
7.81
8.81
9.81
10.81
11.31
12.31
13.31
14.31
16.31
19.31

Insul.
Thk. 4"
D
17.625
18.625
20.875
23.375
25.875
26.875
30.125
32.125
34.125
38.375
44.875

E
6
6
6
9
9
9
9
9
12
12
12

Application:

Features:

Material Data:

D6100 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D6100: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request

Intended to be hung from two threaded rods in


close overhead clearance conditions.

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Minimal overhead clearance requirement
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D6100U)

Performance test results on file:


Available upon request.

Formal submittal sheets available

www.pipeshields.com/d6100

97

Pipe
Shields
Inc.

Model D6200 Insulated 2-Rod Hanger

D4000, D6000

THREADED ROD
(BY OTHERS)

BEAD
(TYP.)

1/4" THK.
TOP STRAP
C

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load ratings, see: D6300.

Pipe
Size

Vert
load
lbs.

16
18
20
24
30

6600
7000
7200
9000
9600

A
1x4
1x4
1x4
1x4
1x4

1/2
1/2
1/2
1/2
1/2

Insul.
Thk. 1"
D

1.25
1.25
1.25
1.25
1.25

9.31
10.31
11.31
13.31
16.31

24.875
26.875
28.875
32.875
38.875

6
9
9
9
12

10.31
11.31
12.31
14.31
17.31
TABLE

Insul.
Thk. 2"
D

26.875
28.875
30.875
34.875
40.875

9
9
9
12
12

Insul.
Thk. 3"
D

11.31
12.31
13.31
15.31
18.31

28.875
30.875
32.875
36.875
42.875

9
9
9
12
12

Insul.
Thk. 4"
D

12.31
13.31
14.31
16.31
19.31

30.875
32.875
34.875
38.875
44.875

9
9
12
12
12

Application:

Features:

Material Data:

D6200 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Compact

D6200: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request

Intended to be hung from two threaded rods in


close overhead clearance conditions.

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Minimal overhead clearance requirement
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D6200U)

Performance test results on file:


Available upon request.

Formal submittal sheets available

98

www.pipeshields.com/d6200

Pipe
Shields
Inc.

D4000, D6000

Model D6300 Insulated 2-Rod Hanger

THREADED ROD
(BY OTHERS)

BEAD
(TYP.)

1/4" THK.
TOP STRAP
C

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thickness.
Contact factory for current inform ation.
Note: For higher load ratings contact factory.

Pipe
Size

Vert
load
lbs.

Bolt
Torq
ft-lbs

20
24
30

8200
11400
11400

50
50
50

1x6
1x6
1x6

1.25
1.50
1.50

Insul.
Thk. 1"
D

11.31
13.31
16.31

28.875
33.375
39.375

9
9
12

Application:
D6300 is designed for use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum
Intended to be hung from two threaded rods in
close overhead clearance conditions.

Insul.
Thk. 2"
D

12.31 30.875
14.31 35.375
17.31 41.375
TABLE I

www.pipeshields.com/d6300

9
12
12

13.31
15.31
18.31

32.875
37.375
43.375

E
9
12
12

Insul.
Thk. 4"
D

14.31
16.31
19.31

34.875
39.375
45.375

12
12
12

Features:

Material Data:

Compact

D6300: Applicable PSI specification document:


No. 209.
Insulation: Calcium silicate asbestos-free,
treated with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive
Structural Inserts: High-density calcium
silicate asbestos free, treated with water
repellant.
Steel Straps: Carbon steel ASTM A-36.
Fasteners: ASTM A-307 plated.
Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request

Easy installation
Eliminates welding to pipe
Copper tubing sizes and pipe sizes
Overlapping galvanized sheet metal jacket
Minimizes heat-loss and/or condensation
Minimal overhead clearance requirement
Other I.D.s and/or O.D.s available on request

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., D6300U)

Insul.
Thk. 3"
D

Performance test results on file:


Available upon request.

Formal submittal sheets available

99

Pipe
Shields
Inc.

Introduction: Section E

INTRODUCTION
SECTION E
INSULATED PIPE RISER CLAMPS
APPLICATION Commercial, Light and Heavy Industrial and Large HVAC Distribution Systems
Models E1000 E1300 Insulated pipe riser clamps for restraint of downward loads only.
These models require the field welding of two (2) factory supplied thrust plates
against the upper side of the riser clamp. The higher the model number in this
series, the higher the load rating.
Models E2000 E2300 Insulated Pipe Riser Clamps for restraint of either, or both, upward or
downward loads. These models require field welding of two (2) factory supplied
thrust plates on both the upper and lower sides of the riser clamp. The higher
the model number in this series, the higher the load rating.
Pipe Shields, Inc. can also supply similar clamps (not catalogued) for the support of pipe insulation.
Insulated clamps (not catalogued) can be supplied for use as pipe guides on vertical risers.
If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at
707-447-5014 or 1-800-538-7007.

Please acquaint yourself with the selection guide at the front of this catalog and the section index on
the page following this introduction, for assistance in determining the most appropriate support for your
application.

100

Pipe
Shields
Inc.

Section E Index

INSULATED PIPE RISER CLAMPS


E1000

MODEL

PIPE
SIZE
RANGE

E1000
E1100
E1200
E1300
E2000
E2100
E2200
E2300

2 - 24
2 - 24
2 - 24
12 - 24
2 - 24
2 - 24
2 - 24
12 - 24

PRIMARY
APPLICATION
DOWNWARD
UPWARD

X
X
X
X
X
X
X
X

X
X
X
X

DUTY

MEDIUM
HEAVY
HEAVIER
HEAVIEST
MEDIUM
HEAVY
HEAVIER
HEAVIEST

TO ORDER, specify:
1. Quantity 20
2. Pipe Size & Type
4 IPS
3. Insulation Thickness
2
4. Model Number
E1000
EXAMPLE:

www.pipeshields.com/e-series

(20) 4

x 2

E1000

101

Pipe
Shields
Inc.

Model E1000, Model E1010,


Model E1020, Model E1030

Insulated Pipe Riser Clamps for Downward Loads

E1000

PIPE
A

a) If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b) One pair thrust plates supplied loose for field
welding, top only.

Pipe
Size

Vert
Load
lbs.

2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24

250
300
400
600
800
1000
1300
1600
1700
2000
2300
2500
2700
2800

0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
0.88
0.88

0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 4.00
0.25 x 4.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00

1.50
1.50
1.50
1.50
1.50
2.00
2.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00

0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625

Insul. Thk. = 1"


F
G
H
3.69
3.94
4.22
4.75
5.25
5.75
6.81
8.06
9.19
9.69
10.69
11.69
12.69
14.69

5.69
5.94
6.22
6.75
7.25
7.75
8.81
10.31
11.44
11.94
12.94
13.94
14.94
17.19

5.13
5.63
6.19
7.25
8.25
9.25
11.38
13.63
15.88
16.88
18.88
20.88
22.88
26.88

Insul. Thk. = 2"


F
G
H
4.75
5.25
5.25
5.75
6.25
6.81
7.81
9.19
10.19
10.69
11.69
12.69
13.69
15.69

6.75
7.25
7.25
7.75
8.25
8.81
9.81
11.44
12.44
12.94
13.94
14.94
15.94
18.19

7.25
8.25
8.25
9.25
10.25
11.38
13.38
15.88
17.88
18.88
20.88
22.88
24.88
28.88

Insul. Thk. = 3"


F
G
H
5.75
6.25
6.25
6.81
7.31
7.81
8.94
10.19
11.19
11.69
12.69
13.69
14.69
16.69

7.75
8.25
8.25
8.81
9.31
9.81
10.94
12.44
13.44
13.94
14.94
15.94
16.94
19.19

9.25
10.25
10.25
11.38
12.38
13.38
15.63
17.88
19.88
20.88
22.88
24.88
26.88
30.88

Insul. Thk. = 4"


F
G
H
6.81
7.31
7.31
7.81
8.44
8.94
9.94
11.19
12.19
12.69
13.69
14.69
15.69
17.69

8.81
9.31
9.31
9.81
10.44
10.94
11.94
13.44
14.44
14.94
15.94
16.94
17.94
20.19

11.38
12.38
12.38
13.38
14.63
15.63
17.63
19.88
21.88
22.88
24.88
26.88
28.88
32.88

Application:

Features:

Material Data:

Model E1000 through E1030 is designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy installation
Positive stop - axially downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E1000 - E1030: specification document: No. 206.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with downward
load only.
Other:
For handling both upward and downward
loads, see E2000

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E1000U)

102

Note: For higher load ratings, see: E1100.


Available in all insulation thickness.

Model
ASTM
For Pipe Material
E1000 A36
Carbon-Steel
E1010
A387GR.22 Chrome-Moly
E1020
A515GR.70
Carbon Silicon
E1030
A304L
Stainless Steel
Insulation: Calcium silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive

Performance test results on file:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized
Other coatings available upon request.
Formal submittal sheets available

www.pipeshields.com/e1000

Model E1100, Model E1110,


Model E1120, Model E1130

Pipe
Shields
Inc.

Insulated Pipe Riser Clamps for Downward Loads


E1000

PIPE
A

a) If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b) One pair thrust plates supplied loose for field
welding, top only.

Pipe
Size

Vert
Load
lbs

2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24

500
600
800
1200
1600
2000
2600
3200
3400
4000
4600
5000
5400
5600

0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
0.88
0.88
0.88
0.88

0.38
0.38
0.38
0.38
0.38
0.38
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 4.00
0.38 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00

1.50
1.50
1.50
1.50
2.00
2.00
2.00
3.00
3.00
3.00
4.00
4.00
4.00
4.00

0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.75
0.75
0.75
0.75
0.75

Note: For higher load ratings, see: E1200.


Available in all insulation thickness.

Insul. Thk. = 1"


F
G
H
3.94
4.19
4.47
5.00
5.50
6.00
7.31
8.31
9.44
10.06
11.06
12.06
13.06
15.06

6.19
6.44
6.72
7.25
7.75
8.25
9.81
10.81
11.94
12.69
13.69
14.69
15.69
17.69

5.38
5.88
6.44
7.50
8.50
9.50
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13

Insul. Thk. = 2"


F
G
H
5.00
5.50
5.50
6.00
6.50
7.06
8.31
9.44
10.44
11.06
12.06
13.06
14.06
16.06

7.25
7.75
7.75
8.25
8.75
9.31
10.81
11.94
12.94
13.69
14.69
15.69
16.69
18.69

Insul. Thk. = 3"


F
G
H

7.50
8.50
8.50
9.50
10.50
11.63
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13

6.00
6.50
6.50
7.06
7.56
8.06
9.44
10.44
11.44
12.06
13.06
14.06
15.06
17.06

8.25
8.75
8.75
9.31
9.81
10.31
11.94
12.94
13.94
14.69
15.69
16.69
17.69
19.69

9.50
10.50
10.50
11.63
12.63
13.63
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13

Insul. Thk. = 4"


F
G
H
7.06
7.56
7.56
8.06
8.69
9.19
10.44
11.44
12.44
13.06
14.06
15.06
16.06
18.06

9.31
9.81
9.81
10.31
10.94
11.44
12.94
13.94
14.94
15.69
16.69
17.69
18.69
20.69

11.63
12.63
12.63
13.63
14.88
15.88
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13

Application:

Features:

Material Data:

Model E1100 through E1130 is designed for use


on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy installation
Positive stop - axially downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E1100 - E1130: specification document: No. 206.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with downward
load only.
Other:
For handling both upward and downward
loads, see E2100

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E1100U)

www.pipeshields.com/e1100

Model
ASTM
For Pipe Material
E1100 A36
Carbon-Steel
E1110
A387GR.22 Chrome-Moly
E1120
A515GR.70
Carbon Silicon
E1130
A304L
Stainless Steel
Insulation: Calcium silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive

Performance test results on file:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized
Other coatings available upon request.
Formal submittal sheets available

103

Pipe
Shields
Inc.

Model E1200, Model E1210,


Model E1220,
Model E1230
E1000

Insulated Pipe Riser Clamps for Downward Loads


C

PIPE
A

a) If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b) One pair thrust plates supplied loose for field
welding, top only.

Pipe
Size

Vert
Load
lbs

2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24

750
900
1200
1800
2400
3000
3900
4800
5100
6000
6900
7500
8100
8400

0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
1.13
1.13
1.13
1.13
1.13
1.13

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

0.50 x 3.00
0.50 x 3.00
0.50 x 3.00
0.50 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 7.00
0.50 x 7.00
0.50 x 7.00
0.50 x 7.00

1.50
1.50
1.50
2.00
2.00
3.00
3.00
4.00
4.00
4.00
5.00
5.00
5.00
5.00

0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.75
0.75
0.75
0.88
0.88
0.88
0.88

Insul. Thk. = 1"


F
G
H
4.19
4.44
4.72
5.25
5.75
6.25
7.31
8.44
9.56
10.06
11.19
12.19
13.19
15.19

6.19
6.44
6.72
7.25
7.75
8.25
9.31
10.69
11.81
12.31
13.44
14.44
15.44
17.69

5.63
6.13
6.69
7.75
8.75
9.75
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13

Insul. Thk. = 2"


F
G
H
5.25
5.75
5.75
6.25
6.75
7.31
8.31
9.56
10.56
11.06
12.19
13.19
14.19
16.19

7.25
7.75
7.75
8.25
8.75
9.31
10.31
11.81
12.81
13.31
14.44
15.44
16.44
18.69

Insul. Thk. = 3"


F
G
H

7.75
8.75
8.75
9.75
10.75
11.88
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13

6.25
6.75
6.75
7.31
7.81
8.31
9.44
10.56
11.56
12.06
13.19
14.19
15.19
17.19

8.25
8.75
8.75
9.31
9.81
10.31
11.44
12.81
13.81
14.31
15.44
16.44
17.44
19.69

9.75
10.75
10.75
11.88
12.88
13.88
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13

Insul. Thk. = 4"


F
G
H
7.31
7.81
7.81
8.31
8.94
9.44
10.44
11.56
12.56
13.06
14.19
15.19
16.19
18.19

9.31
9.81
9.81
10.31
10.94
11.44
12.44
13.81
14.81
15.31
16.44
17.44
18.44
20.69

11.88
12.88
12.88
13.88
15.13
16.13
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13

Application:

Features:

Material Data:

Model E1200 through E1230 is designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy installation
Positive stop - axially downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E1200 - E1230: specification document: No. 206.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with downward
load only.
Other:
For handling both upward and downward
loads, see E2200

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E1200U)

104

Note: For higher load ratings, see: E1300.


Available in all insulation thickness.

Model
ASTM
For Pipe Material
E1200 A36
Carbon-Steel
E1210
A387GR.22 Chrome-Moly
E1220
A515GR.70
Carbon Silicon
E1230
A304L
Stainless Steel
Insulation: Calcium Silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized Steel ASTM A-653.
Glue: Industrial contact adhesive

Performance test results on file:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon Steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized
Other coatings available upon request.
Formal Submittal Sheets available

www.pipeshields.com/e1200

Model E1300, Model E1310,


Model E1320, Model E1330

Pipe
Shields
Inc.

E1000
Insulated Pipe
Riser Clamps for Downward Loads

PIPE
A

a) If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b) One pair thrust plates supplied loose for field welding, top only.
Note: For higher load ratings contact factory. Available in all insulation thickness.

Pipe
Size

Vert
Load
lbs

12

6800

1.13 0.50

0.50 x 7.00

5.00 0.875 9.69 11.94 16.13 10.69 12.94 18.13 11.69 13.94 20.13 12.69 14.94 22.13

14
16

8000
9200

1.13 0.50
1.13 0.63

0.50 x 7.00
0.63 x 7.00

5.00 0.875 10.19 12.44 17.13 11.19 13.44 19.13 12.19 14.44 21.13 13.19 15.44 23.13
5.00 1.00 11.44 13.69 19.38 12.44 14.69 21.38 13.44 15.69 23.38 14.44 16.69 25.38

18
20
24

10000
10800
11200

1.13 0.63
1.13 0.63
1.13 0.63

0.63 x 7.00
0.63 x 7.00
0.63 x 7.00

5.00
5.00
5.00

Insul. Thk. = 1"


F
G
H

Insul. Thk. = 2"


F
G
H

Insul. Thk. = 3"


F
G
H

Insul. Thk. = 4"


F
G
H

1.00 12.44 14.69 21.38 13.44 15.69 23.38 14.44 16.69 25.38 15.44 17.69 27.38
1.00 13.44 15.69 23.38 14.44 16.69 25.38 15.44 17.69 27.38 16.44 18.69 29.38
1.25 15.69 18.19 27.38 16.69 19.19 29.38 17.69 20.19 31.38 18.69 21.19 33.38

Application:

Features:

Material Data:

Model E1300 through E1330 is designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy installation
Positive stop - axially downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E1300 - E1330: specification document: No. 206.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with downward
load only.
Other:
For handling both upward and downward
loads, see E2300

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E1300U)

www.pipeshields.com/e1300

Model
ASTM
For Pipe Material
E1300 A36
Carbon-Steel
E1310
A387GR.22 Chrome-Moly
E1320
A515GR.70
Carbon Silicon
E1330
A304L
Stainless Steel
Insulation: Calcium silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive

Performance test results on file:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized
Other coatings available upon request.
Formal submittal sheets available

105

Pipe
Shields Model E2000, Model E2010,
Inc.
Model E2020, Model E2030

Insulated Pipe Riser Clamps for Upward or Downward Loads

E2000
C

PIPE
A

a) If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b) Two pair thrust plates supplied loose for field
welding, top and bottom.

Pipe
Size

Vert
Load
lbs

2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24

250
300
400
600
800
1000
1300
1600
1700
2000
2300
2500
2700
2800

0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
0.88
0.88

0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 3.00
0.25 x 4.00
0.25 x 4.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00
0.38 x 5.00

1.50
1.50
1.50
1.50
1.50
2.00
2.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00

0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625

Insul. Thk. = 1"


F
G
H
3.69
3.94
4.22
4.75
5.25
5.75
6.81
8.06
9.19
9.69
10.69
11.69
12.69
14.69

5.69
5.94
6.22
6.75
7.25
7.75
8.81
10.31
11.44
11.94
12.94
13.94
14.94
17.19

5.13
5.63
6.19
7.25
8.25
9.25
11.38
13.63
15.88
16.88
18.88
20.88
22.88
26.88

Insul. Thk. = 2"


F
G
H
4.75
5.25
5.25
5.75
6.25
6.81
7.81
9.19
10.19
10.69
11.69
12.69
13.69
15.69

6.75
7.25
7.25
7.75
8.25
8.81
9.81
11.44
12.44
12.94
13.94
14.94
15.94
18.19

7.25
8.25
8.25
9.25
10.25
11.38
13.38
15.88
17.88
18.88
20.88
22.88
24.88
28.88

Insul. Thk. = 3"


F
G
H
5.75
6.25
6.25
6.81
7.31
7.81
8.94
10.19
11.19
11.69
12.69
13.69
14.69
16.69

7.75
8.25
8.25
8.81
9.31
9.81
10.94
12.44
13.44
13.94
14.94
15.94
16.94
19.19

9.25
10.25
10.25
11.38
12.38
13.38
15.63
17.88
19.88
20.88
22.88
24.88
26.88
30.88

Insul. Thk. = 4"


F
G
H
6.81
7.31
7.31
7.81
8.44
8.94
9.94
11.19
12.19
12.69
13.69
14.69
15.69
17.69

8.81
9.31
9.31
9.81
10.44
10.94
11.94
13.44
14.44
14.94
15.94
16.94
17.94
20.19

11.38
12.38
12.38
13.38
14.63
15.63
17.63
19.88
21.88
22.88
24.88
26.88
28.88
32.88

Application:

Features:

Material Data:

Model E2000 through E2030 is designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy installation
Positive stop - axially upward or downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E2000 - E2030: specification document: No. 206.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with upward and/
or downward load.
Other:
For handling downward loads only, see E1000

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E2000U)

106

Note: For higher load ratings, see: E2100.


Available in all insulation thickness.

Model
ASTM
For Pipe Material
E2000 A36
Carbon-Steel
E2010
A387GR.22 Chrome-Moly
E2020
A515GR.70
Carbon Silicon
E2030
A304L
Stainless Steel
Insulation: Calcium silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive

Performance test results on file:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized
Other coatings available upon request.
Formal Submittal Sheets available

www.pipeshields.com/e2000

Model E2100, Model E2110,


Model E2120, Model E2130

Insulated Pipe Riser Clamps for Upward or Downward Loads


E2000

Pipe
Shields
Inc.
C

PIPE
A

a) If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b) Two pairs thrust plates supplied loose for field
welding, top and bottom.

Pipe
Size

Vert
Load
lbs

2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24

500
600
800
1200
1600
2000
2600
3200
3400
4000
4600
5000
5400
5600

0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
0.88
0.88
0.88
0.88

0.38
0.38
0.38
0.38
0.38
0.38
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 4.00
0.38 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00

1.50
1.50
1.50
1.50
2.00
2.00
2.00
3.00
3.00
3.00
4.00
4.00
4.00
4.00

0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.75
0.75
0.75
0.75
0.75

Note: For higher load ratings, see: E2200.


Available in all insulation thickness.

Insul. Thk. = 1"


F
G
H
3.94
4.19
4.47
5.00
5.50
6.00
7.31
8.31
9.44
10.06
11.06
12.06
13.06
15.06

6.19
6.44
6.72
7.25
7.75
8.25
9.81
10.81
11.94
12.69
13.69
14.69
15.69
17.69

5.38
5.88
6.44
7.5
8.5
9.5
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13

Insul. Thk. = 2"


F
G
H
5.00
5.50
5.50
6.00
6.50
7.06
8.31
9.44
10.44
11.06
12.06
13.06
14.06
16.06

7.25
7.75
7.75
8.25
8.75
9.31
10.81
11.94
12.94
13.69
14.69
15.69
16.69
18.69

Insul. Thk. = 3"


F
G
H

7.5
8.5
8.5
9.5
10.5
11.63
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13

6.00
6.50
6.50
7.06
7.56
8.06
9.44
10.44
11.44
12.06
13.06
14.06
15.06
17.06

8.25
8.75
8.75
9.31
9.81
10.31
11.94
12.94
13.94
14.69
15.69
16.69
17.69
19.69

9.5
10.5
10.5
11.63
12.63
13.63
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13

Insul. Thk. = 4"


F
G
H
7.06
7.56
7.56
8.06
8.69
9.19
10.44
11.44
12.44
13.06
14.06
15.06
16.06
18.06

9.31
9.81
9.81
10.31
10.94
11.44
12.94
13.94
14.94
15.69
16.69
17.69
18.69
20.69

11.63
12.63
12.63
13.63
14.88
15.88
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13

Application:

Features:

Material Data:

Model E2100 through E2130 is designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy Installation
Positive stop - axially upward or downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E2100 - E2130: specification document: No. 206.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with upward and/
or downward load.
Other:
For handling downward loads only, see E1200

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E2100U)

Model
ASTM
For Pipe Material
E2100 A36
Carbon-Steel
E2110
A387GR.22 Chrome-Moly
E2120
A515GR.70
Carbon Silicon
E2130
A304L
Stainless Steel
Insulation: Calcium silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive

Performance Test Results on File:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized
Other coatings available upon request.
Formal submittal sheets available

www.pipeshields.com/e2100

107

Pipe
Shields
Inc.

Model E2200, Model E2210,


Model E2220, Model E2230

Insulated Pipe Riser Clamps for Upward or Downward Loads

E2000
C

PIPE
A

a) If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b) Two pairs thrust plates supplied loose for field
welding, top and bottom.

Pipe
Size

Vert
Load
lbs

2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24

750
900
1200
1800
2400
3000
3900
4800
5100
6000
6900
7500
8100
8400

0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.88
0.88
0.88
0.88
0.88
0.88
0.88

0.38
0.38
0.38
0.38
0.38
0.38
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 3.00
0.38 x 4.00
0.38 x 4.00
0.50 x 4.00
0.50 x 5.00
0.50 x 5.00
0.50 x 5.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00
0.50 x 6.00

1.50
1.50
1.50
1.50
2.00
2.00
2.00
3.00
3.00
3.00
4.00
4.00
4.00
4.00

0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.625
0.75
0.75
0.75
0.75
0.75

Note: For higher load ratings, see: E2200.


Available in all insulation thickness.

Insul. Thk. = 1"


F
G
H
3.94
4.19
4.47
5.00
5.50
6.00
7.31
8.31
9.44
10.06
11.06
12.06
13.06
15.06

6.19
6.44
6.72
7.25
7.75
8.25
9.81
10.81
11.94
12.69
13.69
14.69
15.69
17.69

5.38
5.88
6.44
7.5
8.5
9.5
11.88
13.88
16.13
17.13
19.13
21.13
23.13
27.13

Insul. Thk. = 2"


F
G
H
5.00
5.50
5.50
6.00
6.50
7.06
8.31
9.44
10.44
11.06
12.06
13.06
14.06
16.06

7.25
7.75
7.75
8.25
8.75
9.31
10.81
11.94
12.94
13.69
14.69
15.69
16.69
18.69

Insul. Thk. = 3"


F
G
H

7.5
8.5
8.5
9.5
10.5
11.63
13.88
16.13
18.13
19.13
21.13
23.13
25.13
29.13

6.00
6.50
6.50
7.06
7.56
8.06
9.44
10.44
11.44
12.06
13.06
14.06
15.06
17.06

8.25
8.75
8.75
9.31
9.81
10.31
11.94
12.94
13.94
14.69
15.69
16.69
17.69
19.69

9.5
10.5
10.5
11.63
12.63
13.63
16.13
18.13
20.13
21.13
23.13
25.13
27.13
31.13

Insul. Thk. = 4"


F
G
H
7.06
7.56
7.56
8.06
8.69
9.19
10.44
11.44
12.44
13.06
14.06
15.06
16.06
18.06

9.31
9.81
9.81
10.31
10.94
11.44
12.94
13.94
14.94
15.69
16.69
17.69
18.69
20.69

11.63
12.63
12.63
13.63
14.88
15.88
18.13
20.13
22.13
23.13
25.13
27.13
29.13
33.13

Application:

Features:

Material Data:

Model E2200 through E2230 is designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy installation
Positive stop - axially upward or downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E2200 - E2230: specification document: No. 209.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with upward and/
or downward load.
Other:
For handling downward loads only, see E1200

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E2200U)

Model
ASTM
For Pipe Material
E2200 A36
Carbon-Steel
E2210
A387GR.22 Chrome-Moly
E2220
A515GR.70
Carbon Silicon
E2230
A304L
Stainless Steel
Insulation: Calcium silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive

Performance Test Results on File:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized
Other coatings available upon request.
Formal submittal sheets available

108

www.pipeshields.com/e2200

Model E2300, Model E2310,


Model E2320, Model E2330

Pipe
Shields
Inc.

Insulated Pipe Riser Clamps for Upward or Downward Loads

E2000
C

PIPE
A

a. If thrust plate thickness B is greater than


pipe wall thickness, consult factory.
b. Two pairs thrust plates supplied loose for field welding, top and bottom.
Note: For higher load ratings contact factory. Available in all insulation thickness.

Pipe
Size

Vert
Load
lbs

12
14
16

6800
8000
9200

1.13 0.50
1.13 0.50
1.13 0.63

0.50 x 7.00
0.50 x 7.00
0.63 x 7.00

5.00 0.875 9.69 11.94 16.13 10.69 12.94 18.13 11.69 13.94 20.13 12.69 14.94 22.13
5.00 0.875 10.19 12.44 17.13 11.19 13.44 19.13 12.19 14.44 21.13 13.19 15.44 23.13
5.00 1.00 11.44 13.69 19.38 12.44 14.69 21.38 13.44 15.69 23.38 14.44 16.69 25.38

18
20
24

10000
10800
11200

1.13 0.63
1.13 0.63
1.13 0.63

0.63 x 7.00
0.63 x 7.00
0.63 x 7.00

5.00
5.00
5.00

Insul. Thk. = 1"


F
G
H

Insul. Thk. = 2"


F
G
H

Insul. Thk. = 3"


F
G
H

Insul. Thk. = 4"


F
G
H

1.00 12.44 14.69 21.38 13.44 15.69 23.38 14.44 16.69 25.38 15.44 17.69 27.38
1.00 13.44 15.69 23.38 14.44 16.69 25.38 15.44 17.69 27.38 16.44 18.69 29.38
1.25 15.69 18.19 27.38 16.69 19.19 29.38 17.69 20.19 31.38 18.69 21.19 33.38

Application:

Features:

Material Data:

Model E2300 through E2330 is designed for


use on:
Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

All pipe sizes


Easy installation
Positive stop - axially upward or downward
May be supported from below or above
Overlapping galvanized sheet metal jacket
Insulating structural inserts for load transfer
Other I.D.s and/or O.D.s Available on Request
Eliminates condensation sweating on chilled
water risers

E2300 - E2330: specification document: No. 209.


Steel Inner Thrust Plates:

Intended for installation on:


Vertical runs of insulated pipe with upward and/
or downward load.
Other:
For handling downward loads only, see E1300

Temperature Range:

Standard: +40F to +1200F CalSil Insulation


Note: Up to 1800F available upon request.
Cryogenic: -275F to +275F Urethane Insulation.
Add U after the model number (i.e., E2300U).

Model
ASTM
For Pipe Material
E2300 A36
Carbon-Steel
E2310
A387GR.22 Chrome-Moly
E2320
A515GR.70
Carbon Silicon
E2330
A304L
Stainless Steel
Insulation: Calcium silicate asbestos-free, treated
with water repellant.
Jackets: Galvanized steel ASTM A-653.
Glue: Industrial contact adhesive

Performance test results on file:

Structural Inserts: High-density calcium silicate


asbestos free, treated with water repellant.
Steel Straps/Base:Carbon steel ASTM A-36.

Available upon request.

Fasteners: ASTM A-307 plated.


Coating: Primer coated or hot dipped galvanized.
Other coatings available upon request.
Formal submittal sheets available

www.pipeshields.com/e2300

109

Pipe
Shields
Inc.

Introduction: Section G

INTRODUCTION
SECTION G
PIPE CLAMPS, PIPE GUIDE STRAPS, PIPE GUIDE U-BOLTS
APPLICATION For installation on standard 1-5/8 width framing channel.
The models listed in the Section Index are selected based upon the following considerations:

FOR USE WITH


Bare Pipe
Bare Copper Tubing
Insulated Pipe Support
PURPOSE
Clamp
Guide
DUTY
Light
Heavy
If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at
707-447-0030 or 1-800-538-7007.
Please acquaint yourself with the selection guide at the front of this catalog and the section index on
the page following this introduction, for assistance in determining the most appropriate support for your
application.

110

Pipe
Shields
Inc.

Section G Index

PIPE CLAMPS, PIPE GUIDE STRAPS, PIPE GUIDE U-BOLTS


FOR USE ON
BARE
PIPE

G1000

MODEL

BARE
COPPER
TUBING

PURPOSE

INSULATED
PIPE SUPPORT

CLAMP

LIGHT

LIGHT

GUIDE

DUTY

G1200

G1000

G1200

G2000

X
HEAVY

G2200

G2000

G3000

G2200

G3000

HEAVY

LIGHT

TO ORDER, specify:
1. Quantity
20
2. Pipe Size & Type
2 IPS
3. Insulation Thickness
2-1/2
4. Model Number
G1000
5. For use on (bare pipe or insulated pipe support model) A1000
EXAMPLE: (20) 2 x 2-1/2 G1000 (For use on A1000)

www.pipeshields.com/g-series

111

Pipe
Shields
Inc.

G1000

Model G1000 Pipe Shield Clamp

A307 PLD. BOLT

1/4 CLR

1 1/4"

"A" A36 STL.


STRAPS

1 3/8"

PSI MODEL
A SERIES

B.O.P.
T.O.S.

1 5/8"
REF

*PSI A-Series Model purchased separately

Maximum
Pipe Size
3/4
1
1-1/4
1-1/2
2
2-1/2
3

Lateral
Load - Lbs
50
50
50
50
50
50
50

3-1/2
4
5
6
8
10
12

50
50
50
50
50
50
50

TABLE I

Insulation
Thicknesses
0
1/2
3/4
1
1-1/2
2
2-1/2
3
3-1/2
4
TABLE II

Contact factory for pipe sizes or insulation thicknesses not shown.


Note: For neoprene lined clamps, see: G1200; For bolt-on clamps,
see: G2000; For U-bolts, see: G3000.

Insulation and Framing Channel sold separately.

Application:

Features:

Material Data:

Model G1000 is designed for use on:


Hot Water
Steam
Cold Water
Air
Chilled Water
Gas
Dual Temperature
Vacuum

Easy installation
Rugged
Fits standard 1-5/8 width framing channel
Sized to clamp on O.D. of bare pipe
Sized to clamp on O.D. of insulated pipe
support models A1000 through A7400
Complete with top bolt and nut
Other sizes available on request

G1000: Applicable PSI specification document:


No. 208.
Steel A: Galvanized steel 11 ga. X 1-1/4 wide
ASTM A-653

Intended for installation on:


Standard 1-5/8 width framing channels

112

Fasteners: ASTM A-307 Plated.


Formal submittal sheets available

www.pipeshields.com/g1000

Model G1200 G1200


Pipe Clamp Tubing Clamp

A307 PLD. BOLT


1 3/8"

Pipe
Shields
Inc.

Neoprene
Sleeved

1/4 CLR

1 1/4"

"A" A36 STL.


STRAPS
1/4"x2"
NEOPRENE

1 5/8"
REF

Maximum

Pipe Size
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6
8
10
12

Lateral
Load - Lbs.
50
50
50
50
50
50
50
50
50
50
50
50
50
50
TABLE I

Copper
Tubing
O.D.

Maximum
Lateral
Load - Lbs.

1-1/8
1-3/8
1-5/8
2-1/8
2-5/8
3-1/8
3-5/8
4-1/8
TABLE II

50
50
50
50
50
50
50
50

Contact factory for pipe sizes not shown.


Note: For neoprene lined clamps, see: G1000; For bolt-on clamps,
see: G2200; For U-bolts, see: G3000

Framing Channel sold separately.

Application:

Features:

Material Data:

Model G1200 is designed for use on:


Hot water
Air
Cold water
Gas
Chilled water
Vacuum
Dual temperature

Easy installation
Rugged
Fits standard 1-5/8 width framing channel
Sized to clamp on O.D. of bare pipe or bare

G1200: Applicable PSI specification document:

Intended for installation on:


Standard 1-5/8 width Framing Channels

www.pipeshields.com/g1200

copper tubing
Vibration isolator
Complete with top bolt and nut
Other sizes available on request
Neoprene sleeve eliminates galvanic action
between clamp, framing channel and copper
tubing.

No. 208.

Steel A: Galvanized Steel 11 ga. X 1-1/4 wide

ASTMA-653

Fasteners: ASTMA-307 Plated.


Sleeve : 1/4 thick X 2 wide closed cell

neoprene..
Formal submittal sheets available

113

Pipe
Shields
Inc.

Model G2000 Pipe Clamp Shield Guide Strap

G2000

A307 PLD. BOLT


1 /16" CLR
(TYP)

0 CLR

1 1/2"

"A" A36 STL.


STRAPS

1 3/4"
(TYP 3 PLCS)

PSI MODEL
A SERIES

1/2-13 UNC
CHANNEL NUT

1/16" CLR

1 5/8"
REF.

(TYP)

*PSI A-Series Model purchased separately

Maximum

Pipe Size
3/4
1
1-1/4
1-1/2
2
2-1/2
3

Lateral
Load - Lbs.
200
200
200
200
400
400
400

3-1/2
4
5
6
8
10
12

400
400
400
400
400
400
400

TABLE I

Insulation
Thicknesses
0
1/2
3/4
1
1-1/2
2
2-1/2
3
3-1/2
4
TABLE II

Contact factory for pipe sizes or insulation thicknesses not shown.


Note: For neoprene lined straps, see: G2200; For pipe/shield
clamps, see: G1000; For U-bolts, see: G3000.

Insulation and Framing Channel sold separately.

Application:

Features:

Material Data:

Model G2000 is designed for use on:


Hot Water
Steam
Cold Water
Air
Chilled Water
Gas
Dual Temperature
Vacuum

Easy installation
Rugged
Bolts to standard 1-5/8 width framing channel
Sized to clamp on O.D. of bare pipe
Sized to provide approximately 1/16 radial
clearance around O.D. of insulated pipe
support models A1000 through A7400
Complete with top bolt and nut plus two (2) tie
down bolts and channel nuts with springs
Other sizes available on request

G2000: Applicable PSI specification

Intended for installation on:


Standard 1-5/8 width Framing Channels

114

document: No. 208.


Steel A: ASTM A-36 1/4 X 1-1/2
Fasteners: ASTM A-307 Plated.
Coating: Primer coating or hot dipped
galvanized. Other coatings available upon
request.
Formal submittal sheets available

www.pipeshields.com/g2000

G2200
Model G2200 Pipe
Clamp Tubing Clamp

A307 PLD. BOLT


1 3/4"
(TYP 3 PLCS)

Pipe
Shields
Inc.

Neoprene
Sleeved

0 CLR

1 1/2"

"A" A36 STL.


STRAPS
1/4"x2"
NEOPRENE

1/2-13 UNC
CHANNEL NUT

1 5/8"
REF.

Maximum

Pipe Size
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6
8
10
12

Lateral
Load - Lbs
200
200
200
200
400
400
400
400
400
400
400
400
400
400
TABLE I

Copper
Tubing
O.D.

Maximum
Lateral
Load - Lbs

1-1/8
200
1-3/8
200
1-5/8
200
2-1/8
400
2-5/8
400
3-1/8
400
3-5/8
400
4-1/8
400
TABLE II

Contact factory for pipe sizes not shown.


Note: For neoprene lined clamps, see: G2000; For bolt-on clamps,
see: G2200; For U-bolts, see: G3000.

Framing Channel sold separately.

Application:

Features:

Material Data:

Model G2200 is designed for use on:


Hot water
Air
Cold water
Gas
Chilled water
Vacuum
Dual temperature

Easy installation

G2200: Applicable PSI specification

Intended for installation on:


Standard 1-5/8 width Framing Channels

www.pipeshields.com/g2200

Rugged
Bolts to standard 1-5/8 width framing channel
Sized to clamp on O.D. of bare pipe or bare

copper tubing.
Vibration isolator
Complete with top bolt and nut plus two
(2) tie down bolts and channel nuts with
springs.
Other sizes available on request
Neoprene sleeve eliminates galvanic
action between clamp, framing and
copper tubing.

document: No. 208.

Steel A: ASTM A-36 1/4 X 1-1/2


Fasteners: ASTM A-307 Plated.
Sleeve : 1/4 thick X 2 wide closed cell

neoprene.

Coating: Primer coated or hot dipped

galvanized. Other coatings available upon


request.

Formal submittal sheets available

115

Pipe
Shields
Inc.

Model G3000 Pipe Guide U-Bolt Shield Guide U-Bolt


G3000

"D" ROD

1/16" CLR
(TYP)

PSI MODEL
A SERIES

A307
PLD. BOLTS
B

*PSI A-Series Model purchased separately

Insulation and plate sold separately.


Contact factory for pipe, tube sizes, or insulation thicknesses not shown.
Note: For pipe clamps, see: G1000, G1200, G2000, G2200; For shield
clamps, see: G1000; For shield guide straps, see: G2000.
Insulation Thickness
3/4
1

Pipe

Maximum
Lateral

D-Rod

Size

Load-Lbs

Thread

1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4

50
50
50
50
50
50
50
50
50
50

1/4-20
1/4-20
1/4-20
3/8-16
3/8-16
3/8-16
1/2-13
1/2-13
1/2-13
1/2-13

1.25
1.5
1.75
2.25
2.5
2.88
3.5
4.13
4.63
5.13

2.75
3
3
3.5
3.63
3.88
4.38
4.63
4.88
5.13

2.5
2.5
2.88
3.38
3.5
4.13
4.88
5.38
5.88
6.38

3.38
3.38
3.63
4.13
4.13
4.38
4.88
5.13
5.38
5.75

2.88
2.88
3.38
3.38
4.13
4.63
5.38
5.88
6.38
7.5

BARE

1/2

1-1/2
A

2
A

2-1/2
B

3.63 3.38 3.88 4.5 4.38 5.5 4.88 7.13 5.88


3.63 3.38 3.88 4.5 4.38 5.5 4.88 7.13 5.88
3.88
4
4.25
5
4.63 6.25 5.25 7.13 5.88
4.13 4.13 4.38 5.63 5.13 6.25 5.5 7.25
6
4.38 4.63 4.63 5.63 5.13 7.25
6
8.25 6.5
4.63 5.13 4.88 6.25 5.5 7.25
6
8.25 6.5
5.13 5.88 5.38 7.5 6.25 8.5 6.75 9.5 7.25
5.38 6.38 5.63 7.5 6.25 8.5 6.75 9.5 7.25
5.75 7.5 6.25 8.5 6.75 9.5 8.63 10.5 7.75
6.25 7.5 6.25 8.5 6.75 9.5 8.63 10.5 7.75
TABLE I

8.13
8.13
8.13
8.25
9.25
9.25
10.50
10.50
11.50
11.50

6.25
6.25
6.25
6.50
7.00
7.00
7.75
7.75
8.25
8.25

A
10.13
10.13
10.13
10.25
11.25
11.25
12.50
12.50
13.50
13.50

B
7.25
7.25
7.25
7.50
8.00
8.00
8.75
8.75
9.25
9.25

Application:

Features:

Material Data:

Model G3000 is designed for use on:


Hot water
Steam
Cold water
Air
Chilled water
Gas
Dual temperature
Vacuum

Easy installation
Sized to provide approximately 1/16 to 1/8
radial clearance around O.D. of bare pipe or
insulated pipe support models A1000 through
A7000
Complete with 4 hex nuts and 4 plain washers
Other sizes available on request

G3000: Applicable PSI specification document:


No.208
Steel: Low carbon threaded rod.
Hex Nuts: ASTM A-563 Gr. A.
Coating: Primer coating or hot dipped
galvanized. Other coatings available upon
request.
Formal submittal sheets available

116

www.pipeshields.com/g3000

Pipe
Shields
Inc.

1.

2.

3.
1. Insulated pipe support with
temperature range of 40F to 1200F.
2. Cryogenic shoes.
3. Finished with hot dipped galvanized.
4. Pre-insulated pipe supports coated
with red oxide paint.

4.
117

Pipe
Shields
Inc.

1.

2.
4.

3.
1. Cryogenic shoes.
2. Pre-insulated pipe support with hot
dipped galvanized finish.
3. Cold Shoes.
4.Hot dipped galvanized finish on high
temperature pipe supports.
5. Pre-insulated supports for an LNG
plant in Algeria.

5.
118

Pipe
Shields
Inc.

Completed Projects
Aerospace

Banks

Bell Helicopter
Boeing
Hughes Aircraft
Hughes Helicopter
Lockheed
Martin Marietta
McDonnell-Douglas Aircraft
NASA

Bank of America (Los Angeles & Berkeley)


Colorado National Bank (Denver, CO)
Commercial National Bank (Shreveport)
Crocker Bank (Salinas, CA)
First Federal Savings & Loan (Calhoun, CA)
First Interstate Bank (Denver, CO)
Household Bank (Monterey, CA)
San Francisco, CA Federal Savings (CA)
Security Savings & Loan (Salina, KS)
Utica Savings Bank (Utica)

Airports
American Airlines Alliance Airport (Ft.Worth,TX)
American Airlines (Tulsa,OK)
Dulles International Airport Utility Bldg.
Fresno Air Terminal
Greater Orlando International Airport
Greensboro/High Point/Winston Salem Airport
Greensboro Regional Airport
Luis Munoz Marin Airport (Hato Rey, PR)
Portland International Airport
Raleigh-Durham Airport
Riyadh International Airport
San Francisco, CA Airport
Stapleton International Airport
Automotive
American Honda
Bendix
BMW
Chrysler
CPC Fisher
Cummins
Firestone
Ford
General Motors
Goodyear
Hyundai
Mack Truck
Navistar
Nippondenso
Toyota

www.pipeshields.com/major-projects

Breweries
Adolph Coors (Golden,CO)
Miller (Trenton, OH)
Molson (Montreal, Quebec)
Cogeneration
AES/Deepwater Cogeneration Plant (TX)
Altavista Cogen (VA)
Basic Foods (CA)
CFI Cogeneration Plant
California Portland Cement
CamdenCogeneration Plant (NJ)
CBC - SRC Combined Cycle Plant (CA)
Cogentrix (Rocky Mt, NC)
Dow Chemical-Phase I, II, III (LA)
Dow Elsta (The Netherlands)
Dow Midland Cogen (Midland, Ml)
Derwent Cogen (United Kingdom)
Detroit Resource Recovery (Detroit, MI)
East County Regoinal Center
Encogen (Sweetwater, TX)
Fraser Paper Co. (Edmunston, Canada)
Gilroy Foods (CA)
GWF Power Systems
Hershey Chocolate Cogeneration Plant (PA)
Hopewell Cogen (VA)
Louisiana-Pacific (CA)
LSWhitewater Cogen (WI)
Nevada Power (NV)
PT&T Cogeneration Facility (CA)
Pawtucket Cogen (RI)
RJ Reynolds (NC)
San Diego State University (CA)
Tampa Electric Co. (FL)
Teesside Cogen (Middlesbrough, UK)
TransCanada Kapuskasing
TransCanada North Bay

119

Pipe
Shields
Inc.
Ultrasystems Alta Vista Cogen
Wabash River Generating (IN)
Western Cogen (CA)
Commercial
Denver International Airport
Dulles Airport
Henry Ford Health System
NW Airlines
University of Michigan East Engineering Building
University of Michigan Medical Science
University of North Carolina
Computer Facilities
Alps Electronics
Amdahl
Burroughs
Burroughs Wellcome
Digital
Dysan
Fairchild
Fairchild Wafer Fabrication
Fujitsu
Gates Computer
General Electric
Hewlett-Packard Oregon
Hewlett-Packard California
Hewlett-Packard Colorado
Hewlett-Packard Washington
Hewlett-Packard Ohio
Hewlett-Packard Idaho
Honeywell Marine
IBM
Intel Carribbean Interconnect (PR)
InfelCUB (AZ)
Intel Oregon
Intel Ireland
Intel Israel
Intel California
Intel New Mexico
International Rectifier
Johnson Controls
Micron
Monolithic Memories
Motorola White Oak
NCR
National Semiconductor
Perkin-Elmer
Signetics

120

Completed Projects
Sperry
Syntex
Tektronix
Texas Instruments
Trilogy
Varian
Xerox
Construction
Aker Construction, Inc.
Caterpillar Tractor Co.
Caterpillar Tractor Co. Bldg. D (Peoria, IL)
Caterpillar Tractor Co. Bldg. AD (Peoria, IL)
Caterpillar Tractor Co. Bldg. N (Peoria, IL)
Caterpillar Tractor Co. Bldg. BB (Peoria, IL)
Caterpillar Tractor Co. Bldg. J (Peoria, IL)
Caterpillar Tractor Co. Bldg.W (Peoria, IL)
Caterpillar Office Expansion (Peoria, IL)
Caterpillar Steam Heat (Mapleton, IL)
Caterpillar Bldg. R2 (Mossville, IL)
Caterpillar Bldg. KK (East Peoria, IL)
Ferguson
Lauren Engineers and Constructors, Inc.
Offenhauser Company
Quality Plus Services
Vibra-Conn
Correctional Facilities/Prisons
Avenal Medium Security Prison
Baldwin County Courthouse & Jail (AL)
Birmingham Jail Building (AL)
Bullock County Correctional Center
California Medical Facility
Fairfax Detention Center (Fairfax, VA)
Fresno County Jail (CA)
Jail Building (Birmingham, AL)
North Dakota State Penetentiary
PeoriaCounty Jail (Peoria, IL)
Regional Justice Center (Kent, WA)
Southern Maximum Security Complex (CA)
Spring Creek Correctional Facility
State Penitentiary (Bismarck, CA)
Walla Walla State Penitentiary
Food
American Maize Products
Basic
Beringer Vineyards
www.pipeshields.com/major-projects

Completed Projects
Corn Products International
Del Monte
General Foods
General Mills
Gilroy
Hershey Chocolate
Humboldt Creamery
Pepsi-Cola
Peter Paul-Cadbury
Pioneer National Foods
Ragu Foods
Ralston Purina
Wrigleys Gum
Highrises and Office Buildings
One Concord Center (Concord, CA)
101 California (San Francisco, CA)
12 Wyandotte Plaza (Kansas City)
#2 Corporate Center (Concord, CA)
2405 Grand Building (Kansas City)
333 Bush (San Francisco, CA)
456 Montgomery (San Francisco, CA)
595 Market Street (San Francisco, CA)
The Broadmoor Hotel (Colorado Springs)
Bay Hill Four (San Bruno, CA)
Blount International Office Building (AL)
Bowman Grey School/Med. Research Tower (NC)
Capital South Hotel (Columbus, OH)
Chevron (Denver, CO)
Chevron (San Ramon, CA)
Crown Center (Kansas City, MO)
Dean Whitter Reynolds (Dallas, TX)
DuPont (Research Triangle Park, NC)
EastTower (Chicago, IL)
Elihu Harris Office Bldg. (Oakland, CA)
First Stamford Place (Stamford, CT)
Georgia Power Co. Office Tower (Atlanta, GA)
WW Grainger Corporate Hdqrtrs (Skoki, IL)
Hacienda Midrise (Pleasanton, CA)
Hilton Hotel (Cairo, Egypt)
MGM Grand (Las Vegas, NV)
MGM Hotel (Reno,NV)
Mission Viejo Office Bldg (CO)
Hospitals
Affiliated Hospital Center (Boston)
Aga Khan Hosp. & Med. College (Pakistan)
Alta Bates Hospital (Berkeley, CA)
American Cancer Research (Denver, CO)
www.pipeshields.com/major-projects

Pipe
Shields
Inc.
Audrain County Medical Center (St. Louis, MO)
Aultman Hospital (Canton,OH)
Bakersfield Memorial Hospital (Bakersfield, CA)
Baptist Hospital (Birmingham, AL)
Baptist Memorial Hospital East (Memphis, TN)
Bartholomew Hospital (Columbus, IN)
Beth Israel Hospital (Denver, CO)
Boulder Community Hospital (Boulder, CO)
Brighton Community Hospital (Brighton, CO)
Brooks Memorial Hospital (Dunkirk, NY)
Childrens Hospital (San Francisco, CA)
Community Memorial Hospital (Ventura, CA)
Cottage Hospital (Santa Barbara, CA)
Crippled Childrens Hospital (Richmond, VA)
Dameron Hospital (Stockton, CA)
David Grant Medical Facility (Fairfield, CA)
Delray Community Hospital (Delray Beach, FL)
East & West Alabama Medical Center (AL)
El Camino Hospital (Mountain View, CA)
Fresno Community Hospital (Fresno, CA)
Greenville Memorial Hospital (Greenville, SC)
Guernsey Memorial Hospital (Cambridge, OH)
Harrisburg State Hospital (Harrisburg, PA)
Holy Name of Jesus Hospital (Gadsden, AL)
Kaiser Hospital (Fontana, CA)
Kaiser Hospital (Oakland, CA)
Kaiser Hospital (Vallejo, CA)
Kaiser Hospital (Sacramento, CA)
Kaiser Hospital (West Los Angeles, CA)
Kaiser Medical Center (Denver, CO)
Kaiser Permanente Medical Center (Riverside,CA)
Kaiser Permanente Medical Center (Vacaville, CA)
Kaiser Sunset Hospital (Long Beach, CA)
Lutheran General Hospital (Park Ridge, IL)
Merritt Hospital (Oakland, CA)
Mills Hospital (Marin, CA)
Moffitt Hospital (San Francisco, CA)
Mt. Zion Hospital (San Francisco, CA)
New David Grant Medical Facility (Travis AFB)
Olive View MedicalCenter (Sylmar, CA)
Pleasant Valley Hospital (Camarillo, CA)
Porter Memorial Hospital (Denver, CO)
Presbyterian Hospital (Denver, CO)
Queen Alia Heart Institute (Ammaivjoidah)
Redding Medical Center (Redding, CA)
Robert Packard Hospital (Syracuse, NY)
Rose Medical Center (Denver, CO)
Salinas Valley Memorial Hospital (Salinas, CA)
San Francisco, CA General Hospital (San
Francisco,CA)
Santa Monica Hospital (Santa Monica, CA)

121

Pipe
Shields
Inc.
Shriners Hospital (Sacramento, CA)
St. Francis Hospital (Memphis, TN)
St. Joseph Hospital (Denver,CO)
St. Lukes Hospital (Tempe, AZ)
Stanford Medical Center (Stanford, CA)
Sutter General Hospital (Sacramento, CA)
Thunderbird Samaritan Hospital (Pheonix, AZ)
Univ. of Cincinnati, OH General Hospital ( OH)
Univ. of Michigan Burn Center (Detroit, MI)
Univ. of Michigan Hospital (Detroit, MI)
VA Hospital (Martinez, CA)
VA Medical Centers
Ventura County Hospital (Ventura, CA)
West Alabama Medical Center (Montgomery, AL)
Industrial
3M
Ascension Industries, Inc.
Boeing 25-01
Boeing 25-02
Boeing 40-37
Boeing 40-41
Boeing Hot GasTest Facility
Boeing MBU-2
Boeing Site Development
Boeing Skin & Spar Facility
Caterpillar
Chrysler Technology Center
Chrysler/CTC Environmental Lab
Cummins Engine
Eastman Chemicals
Ford Cold Fluids
Ford (Lima, OH)
G.E. Silicones
Genentech
Huls America (R.C.)
Hyundai 100,000 MTA SM Plant
Intel Energy Center (Folsom,CA)
Intel JP2
Intel UF2
Intel-Rio Rancho
Kodak
Loctite
Nissan Motor Manufacturing
Proctor & Gamble
Toyota, Building 100
Uniroyal

122

Completed Projects
Laboratories
Abbott-Ross Laboratories
Bio-Rad Labs
Cetus Labs
Chem/Vet LabBuilding,University of Wyoming
Colorado State University Controlled Lab
Cutter Laboratories
Genentech
Miles Lab (Clayton, NC)
Newport Aquaculture Lab
Sandia Molten Salt Receiver
Sandia Radiation Hardening Circuits Facility
Sphio Research and Development
Surge Building - Stanford Hospital
Underwriters Laboratories
UC Berkeley SSCL Lab
UC Davis Agricultural Sciences Lab
UC Lawrence Livermore Lab Bldg. 490/494
University of Delaware-Colburn Lab
Zoecon Labs
Military and/or Government
Air National Guard Hangar/Harrisburgh Intl
Airport
Ames Research, Moffett Field
Army Defense Depot Mech. Freight Term.
(Memphis)
Brooke Army Medical Center
Cape Canaveral
Castle AFB Medical/Dental Facility
David Grant Med. Fac. Travis AFB (Fairfield,CA)
Elmendorf AFB, Satcom Ground Terminal
Federal Bureau of Investigation (San Francisco,
CA)
Fourth Antenna Raydome Support (Mathews,
NC)
Hamilton AFB
King Khalid Military City (Saudi Arabia)
Kings Bay Rtl.
Knights Ferry Administration Building
Lawrence Radiation Lab Building 3.2
Lowry AFB
Medical/Dental Facility (Castle AFB)
McClellan AFB (CA)
Navy Submarine Spt. Fac./Pier Steam Pit (San
Diego)
Pentagon
Sandia Radiation Hardening Facility
United Technology (Colorado Springs, CO)
www.pipeshields.com/major-projects

Pipe
Shields
Inc.

Completed Projects
United Technologies Corporation (Coyote, CA)
Warren AFB
Weapon Systems Support Facility (China Lake, CA)
Wyoming International Guard (Cheyenne, WY)
Petrochemical
Allied Signal
Amoco Project
ARCO Chem
Ashland Petroleum Hydrogen Plant
ATOChem
Chevron Asphalt Plant
Chevron St. James
China Petrochem
Citcon
Cosmar
CVIP, Inc
DeepwaterIodines
Dow Elsta
Dow Flame Kit
Dow Hydro Carbons (Ft. Saskatchewan, Canada)
Dow (Freeport, TX)
Dow - Hydro Carbons Project
Dow - Oyster Creek Connection
Dow - Tiger Bay
DuPont Beaumont MMA Project
DuPont Sabine
DuPont - Cooper River
DuPont (Corpus Christi, TX)
DuPont (Gulf States)
DuPont (Taiwan)
Ethyl Corporation
Exxon
Formosa Heavy Industries (Taiwan)
Gulf Coast Fractionators
Hitachi
Hoechst Celanese Millhaven Resins
Huntsman Styrene
ICI Americas
Koch Refinery
Mobay Corporation
Mobil Bakersfield
Monsanto Environmental Chemical
Nan Ya Plastics (South Carolina)
Occidental Chemical/Bipheyl
Petro-Chem Development Company
Sadaf
Samsung
Shell Chemical, BPA - 4
Star Enterprises - Star Port Arthur
www.pipeshields.com/major-projects

Sun Oil - Sun Refinery & Market


Tennessee Eastman - Eastman FGAP Proj.
Unocal 250 KW Demp Plant
Vista Chemical
Westlake Styrene Corporation
Yukong Oxychem (China)
Pharmaceutical
American Pharmaseal
Bayer-Miles
Ciba-Geigy Corporation
Eli Lilly
Eli Lilly Building C644
Eli Lilly Bldg 98
Eli Lilly K8 Cafeteria
Eli Lilly Research Center
Eli Lilly T29
Eythyl Corporation
Genentech - SSF
Genentech - Vacaville
L.Lynch & Company Ltd
Merck Project B
Miles Lab
Pfizer Groton
Pfizer Litesse
Roche Carolina
San Ramon Fuel Cell Pilot Plant
Shared Brine/Upjohn
Upjohn
Power
Alvin W. Vogtle
Arkansas Nuclear One
Bellefonte - 1 & 2
Boardman Fossil Fuel Plant
Callaway 1
Camden Cogen
Colstrip Fossil Fuel Plant
Crystal River - 3
Diablo Canyon -1 & 2
DuPont
Ebasco
Exxon
Florida Power & Light (Ft. Lauderdale, FL)
Ghazlan
Gordonsville
HB Robinson
Indian Point - 3
Joseph M. Farley -1 & 2

123

Pipe
Shields
Inc.
Labadie Fossil Fuel Plant
Laguna Verde -1 & 2
Lauderdale Re-Power
Limerick - 1 & 2
LS Whitewater
Miller Steam Plant
Montana Power, Units 3 & 4
Monticello
Nevada Power
North Anna -1 & 2
Nuclear One 1
Pawnee Fossil Fuel Plant
Peach Bottom - 2 & 3
Plant Scherer - Units 1 & 2
Plant Scherer - Unit 4
RanchoSeco
San Onofre -1,2 & 3
Satsop Power Plant
Seabrook -1 & 2
Shearon Harris -1
Sioux Fossil Fuel Plant
Sithe
St. Lucie
Surry
Susquehanna 1 & 2
TECO (Florida)
Transcanada North Bay
Transcanada Kapuskasing
Turkey Point - 3 & 4
Vogtle 1
Wabash Coal Gasification (Indiana)
Wabash River Gen. Station
Watts Bar 1 & 2
Wolf Creek
WPPSS 1 & 4
WPPSS 2
WPPSS 3 & 5
Process
3M
EI DuPont Experimental Station
Haliburton Headquarters Plant
Kimberly Clark
Meredith Burda Plant
Northwest Pipeline LNG II Plant
Proctor & Gamble
Whitney Canyon Gas Plant
Public Works
4th District Court (Chicago, IL)
Alameda County Offices

124

Completed Projects
Albuquerque Law Enforcement Center
Bessemer Civic Center
Bulk Mail Facility (Pittsburgh)
Clay County Justice Center
Cleveland Public Library
Communications Emergency Operations Ctr.
Denver, CO Museum of Natural History
Foothill Community Law & Justice Center
Hayward Hall of Justice
Humboldt County Courthouse
Loop Transportation Center (Chicago, IL)
Los Angeles Metro System
Lucas State Office Bldg. Chiller Addition (IA)
Montgomery Courthouse
Montgomery Fire Station
Moscone Convention Center
Mountain Bell (Colorado Springs, CO)
Ntl. Archives, Federal Records (San Bruno,CA)
Ohio Theater (Columbus, OH)
Opera House (San Francisco, CA)
San Jose Convention Center
San Jose Museum of Art
Shasta CountyJustice Building
Social Security Headquarters (Richmond, VA)
Sunnyvale Public Safety Building
Tallahassee Capitol Complex
US Embassy (Moscow)
US Federal Courthouse (San Jose, CA)
Pulp & Paper
Celanese Fibers Operations
Champion Paper Company
Fraser Paper Company
Louisiana-Pacific
Olin Corporation, Ecusta Paper & Film Group
Wallula - Ponderosa Pulp & Paper (WA)
Weyerhaeuser
Refineries
Amoco Gas Plant (Evanston, WY)
Exxon (Baytown,TX)
Kuwait National Petroleum Refinery
Ultramar Canada, Inc. - Vacuum Unit
Schools
Aga Khan Hospital & Medical College
(Pakistan)
Basic Science Building, University of Alabama
www.pipeshields.com/major-projects

Pipe
Shields
Inc.

Completed Projects
Bellarmine College, ODonnell Hall
Bowman Grey School of Medicine (NC)
Brigham Young University
Buffalo State University (Buffalo, NY)
Cherry Creek Elementary School (Denver, CO)
Cherry Creek High School (Denver,CO)
Copperfield Junior High School (TX)
Douglas County High School (Denver, CO)
Harvard University (MA)
James Madison Univ. Heat Recovery Project
Lowry High School (Winnemucca, NV)
Lurleen Wallace Cancer Institute(Unv. of AL)
Mendocino College
Michigan State University (East Lansing, MI)
New Bradford Central School (Bradford, NY)
Northwestern University (Chicago, IL)
Santa Clara University Energy Center
Stanford Psychiatric Building
Stanley School (Stanley, ND)
State University (Oswego, NY)
UC Davis Life Science Building (Davis, CA)
UC Davis Cole B
UC Davis, Veterinary Hospital
UCSF, CA
UCSF, CA Koret Vision
UCLA Louis Factor Health Sciences Building
University of Akron
University of Alabama
University of Delaware (Newark, DE)
University of Michigan (Ann Arbor, MI)
UNC Chiller (Chapel Hill)
University of Tennessee College ofMedicine
Universityof Wyoming
Wayne State University, Outpatient Clinic
Western Michigan University
West Jefferson Junior High School (Denver, CO)
WMU Goldsworth (Kalamazoo, MI)

RJ Reynolds Building 95-1


RJ Reynolds Downtown Building
RJ Reynolds Flanor Building
RJ Reynolds Leaf Storage Warehouse
RJ Reynolds M &K Warehouse
RJ Reynolds Plaza Building
RJ Reynolds Skinners Warehouse
RJ Reynolds Switch Gear Relocation
RJ Reynolds Tobaccoville
RJ Reynolds Whitaker Park
Waste Treatment
Cedar Creek Sewage Treatment Plant
Lead-Deadwood Sewage Treatment
Manitowoc Wastewater Treatment Plant
Pacific Gas & Electric Waste Line (Antioch, CA)
Rawhide River Project
Red Oaks Waste Water Treatment Plant (Red Oak,
IA)
Rock Creek Sewage Treatment Plant
San Francisco Waste Treatment
Solid Waste Recovery System (Newport News,VA)
Sunnyvale Sewage Treatment Plant
Waste Treatment Facility (Medway, MA)

Solar
SEGS I & II (Daggett, CA)
Tobacco
Phillip Morris
RJ Reynolds Building 50-1
RJ Reynolds Building 601-11
RJ Reynolds Building 611-16
RJ Reynolds Building 611-7
RJ Reynolds Building 631-1
RJ Reynolds Building 90-3
www.pipeshields.com/major-projects

125

Pipe
Shields
Inc.

FAQs

FREQUENTLY ASKED QUESTIONS


Why should I use insulated pipe supports?
The insulated pipe support can save you money on your bid and on the job. On commercial and light
industrial work, when an insulated pipe support is installed in a clevis hanger, the Insulation Contractor
never touches the pipe hanger and only needs to make a simple butt joint between the pipe insulation and
the insulated support. The Mechanical Contractor does not have to return for expensive, final adjustment.
On heavy industrial work, on alloy steel or stainless steel pipe, there is no welding, no pre-heat or
post-heat, no certified welders and no x-ray inspection required. On any type of work, if otherwise
permitted, there is an insulated pipe support available which will allow you to maximize the support spacing
and, thus, reduce the number of supports required on the job. The Insulation Contractor should reduce his
bid to allow for labor and materials not used.
What is the primary reason why I should consider insulated pipe supports in my building/plant?
Insulated pipe supports are energy conservation devices and continue to pay for themselves over the full
life of the building/plant. On request, Pipe Shields, Inc. will make an economic analysis for your
particular application.
Are there any other reasons why I should consider insulated pipe supports?
Insulated pipe supports also provide reduction in noise and vibration. Insulated pipe supports on hot lines
provide for personnel comfort and protection in tunnels, corridors, mechanical rooms and other tight places.
Insulated pipe supports on hot lines also often result in a reduced heat load for an air conditioning system
to handle. Insulated pipe supports permit the Insulating Contractor to make a perfect vapor barrier seal
which is also effective against the damaging effect of water intrusion - a condition impossible to achieve
with a welded shoe configuration.
How do I know which models to use?
The catalog is arranged to simplify the selection process. To obtain the most benefit from the catalog,
familiarize yourself with the Selection Guide, Product Data and Indexes to the various sections of the
catalog. In addition, many of the product data sheets have references to other models having features such
as higher load ratings or provisions for thermal expansion or physical restraint.
Why are there so many models of insulated pipe supports?
The load rating of each support is often dependent upon how the support is mounted (flat surface, roller,
clevis hanger). Heavy valve loads, wind loads, and/or thermal loads may have to be accommodated.
Provision for axial and/or lateral travel, due to thermal growth, may have to be made. The pipe may require
guiding or restraint. Supports mounted on 10'-0 centers do not require the load carrying capability that is
required by supports on 40'-0 centers. These and other considerations resulted in the creation of a family
of insulated pipe supports enabling the customer to select the most economic unit sufficient for the purpose
intended.

126

www.pipeshields.com/faqs

FAQs

Pipe
Shields
Inc.

Why does the same model commercial support (example A3000) have three different load ratings?
When this cylindrical shaped support is mounted on a flat surface, its load carrying capability is limited
because there is only line contact at the underside of the support. Similarly, there is an even greater
limitation on the load carrying capability of this model when mounted on pipe rolls because of the point
contact resulting in deformation of the sheet metal jacket and/or damage to the calcium silicate insulation
under heavy loads. In a ring or clevis hanger, however, the load is well distributed through the lower 180
section, permitting higher load ratings.
Why can't I specify pipe supports the "old way"?
Weld-on supports represent heat sink conditions with resulting energy loss. Expensive like materials,
welding and inspection procedures are often required on high temperature alloy steel pipe to minimize
the likelihood of stress corrosion and to assure a sound weld. Available standard catalog hangers may
not permit the maximization of support spacing and the resulting minimization of the number of supports
required on the job - possible with the use of pre-insulated pipe supports. Today's light density fiberglass
insulation has insufficient compressive strength to support most pipe loads without crushing out - often
requiring the contractor to be innovative at each support point. Load rated insulated pipe supports offer an
appropriate and economic solution.
My design requirements are special and I do not find exactly what I want in your catalog. Why don't
I design a pipe support for myself?
Pipe Shields, Inc. has developed a "standard concept" for its family of insulated pipe supports. Utilizing that
concept, we have been able to readily modify it and adapt it to meet a wide variety of applications. Many of
these modifications and adaptations have not been included in this catalog. In addition, the materials and
design configurations have been extensively tested and/or analyzed, allowing Pipe Shields, Inc. to readily
and economically respond to any pipe support need. As experts in the insulated pipe support field, we can
save you expensive design time - especially on "fast-track" projects.
How long does it take to install an insulated pipe support?
This depends upon the size and model considered. The popular commercial and light industrial supports
up through 8 pipe size can generally be installed by one man in half-a-minute or less. The two halves, with
their overlapping jackets, merely slip together over the pipe at the point of support. If for any reason, the
support must be relocated, it is just as easy to remove and move, as it was to install in the first place. The
larger the diameter, heavy industrial supports may require the time of two men for 15 minutes plus a welder
to attach the base plate to the support structure. As with the small bore commercial supports, these too are
easy to relocate.
Why dont I add Pipe Shields, Inc.'s name to a list of methods and/or vendors currently in our
specifications?
To control the quality of pipe supports on the project, it is necessary to avoid the ambiguity present in
many of today's existing specifications. The Insulating Contractor must be made aware that the purchase
and installation of insulated pipe supports are responsibilities of the Mechanical Contractor, so that his bid
may be adjusted accordingly. To assist you, we have prepared typical, general mechanical specifications
for insulated pipe supports which may be found elsewhere in this catalog. If you have a current set of
specifications, send it to us for our review and recommendations.

www.pipeshields.com/faqs

127

Pipe
Shields
Inc.

FAQs

Can heat trace lines be accommodated?


Pipe Shields, Inc. has supplied many insulated pipe supports, each with one or more grooves to handle
heat traces. Advise us of the number, size, configuration and orientation of your heat tracing and we can
readily and economically incorporate the necessary groove(s) in the supports you require.
How can I make certain that insulated pipe supports will be used in my facility?
Whether you have an in-house engineering capability or sub-contract the engineering effort to an outside
firm, you should make clear that one or more of the typical General Mechanical Specifications, included
elsewhere in this catalog, are followed. Over the years, specifications have become so ambiguous that
they often result in a complete license to have anything but what the owner/operator wishes installed on the
project. In addition, a properly written specification places the responsibility for the purchase and installation
of insulated pipe supports with the Mechanical Contractor, resulting in a lower bid - (and lower total project
cost) from the Insulating Contractor. Pipe Shields, Inc. has an open offer to work with you and/or your
Engineer, to review your current specifications and provide recommendations to assure that the most
economic and appropriate supports are used on your project.
Is there any reason to consider insulated pipe supports on chilled water lines?
Old-style sheet metal insulation "protection" shields, when used with today's low density fiberglass
insulation, often damages the very insulation and vapor barrier they are supposed to protect when the
shield moves in relation to a clevis hanger, becomes unbalanced, and cuts through both the vapor barrier
and the insulation. An insulated pipe support provides the best protection against condensation/sweating
problems and enhances the life of the insulation system.

High temperature insulated pipe support. The base, clamps, nuts, jackets and bolts are all
fabricated from hot-dipped galvanized carbon steel. The cold shoes have 3 thick high density
calcium silicate insulation, and are designed for 12 - 42 diameter pipes. The dimensions are
47 L X 51 W X 16 H.

128

www.pipeshields.com/faqs

Pipe
Shields
Inc.

1.

2.

4.

3.
1. 25-7/8 Diameter high temperature supports for a rush
job.
2. 48 Guided pre-insulated pipe supports for high
temperatures.
3. Hot shoes for a power plant in Argentina.
4. These cryogenic supports are fabricated from 20 PCF
polyurethane insulation, weigh 650 lb. each and are designed for 30 diameter pipe.
5. 58 Diameter high temperature rotational and axial
stop insulated supports.

5.

Pipe
Shields
Inc.

Pipe Shields, Inc. Product Catalog


a subsidiary of Piping Technology & Products, Inc.

Engineered Pipe Supports


(Variables, Constants & Big Ton
Springs)

Plant Location:
3701 Holmes Road
Houston, TX 77051-1545
Mailing Address:
P.O. Box 34506
Houston, TX 77234-4506

site:

www.pipeshields.com
www.pipingtech.com
email: info@pipeshields.com
info@pipingtech.com
Phone: (800) 538-7007
(713) 731-0030
Fax: (707) 447-4641
(713) 731-8640

Sales Office:
O
5030 Business Center Dr. St. 210
Fairfield, CA 94534

Pre-Insulated Pipe Supports


(Hot Shoes for High Temp.
Pipe Lines, Cold Shoes for
Cryogenic Lines)

Expansion Joints (Metallic Bellows,


Thick Wall, Thin Wall, Furnace Bags. Support Assembly
Components (Pipe Hangers,
Rectangular, Slip-Type, Fabric)
Clamps & Risers, Saddle
Supports & Coverings,
Pipe Shoes, Guides & Anchors
Hardware, Rods & U-Bolts,
(Pipe Shoes & Stands, Cylinder
Hold-Down Clamps, Beam
Pipe Guides, Anchors)
Attachments, Clevis Hangers)
Slide Plates (PTFE, 25% Glass
Dynamic Restraints
Filled, Bronzphite, Marinite,
(Hydraulic Shock & Sway
Graphite)
Supressors, Vibration Control
ASME/Misc. Fabricated Products Sway Braces, Mechanical
(ASME Pressure Vessels Tanks, Pig Snubbers, Sway Struts)
Launchers & Receivers, Duct &
Transition Pieces, Spectacle & Line Value-Added Services (24x7
Quick-Turn / Emergency,
Blinds, Bellmouth Reducers,
Stress Analysis / Product
Instrument Supports, Dampers /
Testing, Engineering & Design,
Louvers, Conical Strainers)
Field Services)

2nd Edition

Piping Technology & Products, Inc.

Copyright 2014 Pipe Shields Inc. Printed in USA 25M December 2014 2nd Edition

Вам также может понравиться