Академический Документы
Профессиональный Документы
Культура Документы
ExamID:84
90multiplechoicequestions
31/2hourlimit
Openbook
Scope:
TheStructuralMasonrySpecialInspectorisresponsibleforenforcingtheconstructiondetailscontainedin
theapprovedplansandspecificationsforstructuralmasonryelementsofthebuilding.Thespecial
inspectorreviewsthestatementofspecialinspectionsandtheapprovedplansandspecifications,and
verifiesthatstructuralmasonrymaterialsandplacementofmasonry,reinforcement,andgroutare
installedasshownandasspecifiedintheapprovedplansandspecifications.Thespecialinspectoris
responsibleforcollectingsamplesofmaterialsandforperformingrequiredtests.Thespecialinspectoris
responsibleforwritingandsubmittingrequiredreports,includingreportsofitemsthatdonotcomply
withtheplans,tothebuildingofficial,contractor,and/orregistereddesignprofessional.
01
GeneralRequirements
9%
0101 DutiesandResponsibilities
Reviewapprovedplans,specifications,andsubmittalsforspecialinspectionrequirements.
Complywithspecialinspectionrequirementsoftheenforcingjurisdictioninaccordancewith
theapplicablecode,approvedplans,andspecifications.
3%
0102 NotificationofDiscrepancies
Notifythecontractorofdeviationsfromapprovedplansandspecifications.Ifthedeviations
areuncorrected,notifythearchitectorengineerofrecordandthebuildingofficialof
3%
0103 InspectionReports
Submitprogressreportstothearchitectorengineerofrecordandthebuildingofficial,
describingtestswhichwereperformedandcomplianceofwork.Submitfinalsummary
reportstatingwhetherworkrequiringspecialinspectionwasinconformancewiththe
approvedplansandapplicableprovisionsofthebuildingcode.
3%
02
Materials
16%
0201 MaterialVerification
Verifythatbrick,block,cement,lime,aggregates,reinforcement,connectors,water,
admixtures,andothermaterialsarethetypespecifiedandapproved.Verifythatmaterials
areproperlystored.
3%
0202 Mortar
Verifythatmixproportions,materialhandling,andmixingareinaccordancewithcode
requirements.
3%
0203 Grout
Verifythatgroutisbatchedinaccordancewithapprovedmix.
3%
0204 Testing
Determinetherequiredmaterialstrength'stypeandfrequencyofteststobeperformed.
Observesampling,fieldtesting,andfabricationoftestspecimens.Verifythatmasonry
strengthmeetsapprovedspecifications.
4%
0205 SpecimenHandlingandProtection
Verifypropersampleidentification,sitestorage,protection,andtransportationtothetesting
laboratory.
3%
03
MasonryPlacement
21%
0301 MasonryUnits
Verifythattheconditionofsubstrateisacceptableforplacement,thatmortarisproperly
placed,andthatthemasonryunitsareplacedinaccordancewiththeapprovedplans.
7%
0302 EmbeddedItems
Verifythatthetype,quantity,size,spacing,andlocationofembeddeditemsareasspecified.
6%
0303 MovementJoints
Verifythatthelocationandpreparationofmovementjointsareinaccordancewiththe
approvedplans,specifications,andbuildingcoderequirements.
4%
0304 Protection
Verifythatthemasonryisprotectedfromtemperatureextremesandadverseweather
conditions.
4%
04
ReinforcementandConnectorPlacement
30%
0401 Size,Spacing,andPlacement
Verifythatthereinforcingsteelandconnectorscomplywithrequiredsize,spacing,profile,
condition,andquantityrequirements,asindicatedbyboththeapprovedplansand
installationdrawings.
9%
0402 Tolerances,Clearances,andCoverage
Verifythatreinforcingsteelandconnectorsareplacedintheproperlocationwithin
acceptabletolerances.Verifyminimumcoverageandclearancetomasonrysurfaces.
8%
0403 Details
Verifythathooks,bends,ties,stirrups,andsupplementalreinforcementarefabricatedand
placedasspecified.
7%
0404 Splices
Verifythatrequiredlaplengths,stagger,andoffsetsareprovided.Verifyinstallationof
approvedmechanicalconnectionspermanufacturersinstructionsand/orevaluationreports.
6%
05
GroutPlacement
24%
0501 Preplacement
Verifythatgroutspacesarefreeofobstructionsandthatcleanoutsareprovidedasrequired.
9%
0502 Placement
Verifythatmethodsofconveyingandplacinggroutavoidcontaminationandsegregationand
complywithtimelimitsandgroutliftrequirements.
8%
0503 Consolidation
Verifythatgroutisbeingproperlyconsolidatedandreconsolidatedduringplacement.
7%