Академический Документы
Профессиональный Документы
Культура Документы
106-PFC Globe
Pressure Reducing
KEY FEATURES
Product Overview
The 106-PFC / 206 PFC Pressure Modulation Valve is a pressure reducing valve with a special
3DWHQWHGSLORWWKDWLQFUHDVHVGRZQVWUHDPSUHVVXUHDVRZLQFUHDVHV
7KH3)&YDOYHDOWHUVDQGFRQWUROVSUHVVXUHZLWKRZWRFUHDWHYLUWXDOO\FRQVWDQWSUHVVXUHDWWKHFULWLFDO
pressure point in a system. It will also automatically adjust for distribution friction losses. The PFC valve
will deliver consistent performance as it has no electrical components and is not affected should the
YDOYHFKDPEHUEHRRGHG7KHYDOYHPD\EHXVHGZKHUHYHUDVWDQGDUG359LVLQVWDOOHG
Typical Application
A gate valve immediately downstream of the PFC Control Valve is partially closed to produce for
H[DPSOHSVLEDUSUHVVXUHGURSDWPD[LPXPRZ7KLVSUHVVXUHGLIIHUHQWLDOLVDSSOLHGWR
each side of an actuating diaphragm which is connected to the yoke of the pressure reducing pilot.
Increasing the differential raises the pilot setting and raises downstream pressure approximately 18 psi
/ 1.24 bar in this example (6 times gate valve differential).
Main Supply
PFC
Remote users
105
2011.4
www.singervalve.com
Schematic Drawing
1. Main Valve - 106-PG or 206-PG
2. Isolation Valve (2A, 2B, 2C, 2D) - standard on
all valves
3. Strainer - 40 mesh stainless steel screen
4. Model 26 Flow Stabilizer / Opening speed control
Standard (106 or 206) on at diaphragm valves
Optional on rolling (S106 or S206)
diaphragm valves
5. Fixed Restriction
6. Model 160-PFC Pressure / Flow Control Pilot
(6A, 6B)
6C. Actuator position indicator
6D. Travel stop (adjustable)
7. Gate or buttery valve (adjustable) - not included
8. Model 852-B Air Bleed and Test Valve
9. Model 852-B Speed Control
10. Downstream connector
Schematic A-8270E
Selection Summary
1. The Singer model 106-PFC / 206-PFC should be sized as a normal pressure reducing valve. Refer
to section 106-PR / 206-PR, page 108, for size selection and main pilot spring ranges (pages 249).
2. Installation is the same as a standard pressure reducing valve. See section 106-PR / 206-PR,
page 108. Customer to connect 3/8 in / 15 mm or 1/2 in / 10 mm tubing downstream of the partially
closed gate valve.
3. Maximum pressure increase range over base setting: 35 psi / 2.4 bar.
4. For correct application provide
i. Maximum & minimum inlet pressure and base (minimum) outlet pressure setting
ii. Maximum & minimum ow rates
iii. Pressure increase _____ psi / _____ bar at _____ USGPM / L/s
iv. Maximum pressure increase at any ow _____ psi / _____ bar.
5. For good control, inlet pressure should be at least 15 psi / 1 bar valve loss greater than the
maximum downstream pressure desired.
6. (nsure the ange ratings exceed the maximum worNing pressure.
SSecications
The valve shall be a Singer Valve model 106-PFC / 206-PFC, size _____, ANSI Class 150 (ANSI
300, ANSI anges drilled to IS2 PN 10 / 16 / 25 or 40) pressure rating / ange standard, globe
(angle), style valve. The Model PFC Actuator inlet pressure will vary from ___ to ___ psi /
___ bar. The low ow minimum downstream pressure shall be controlled at ___ psi / ___ bar
increasing to ___ psi / ___ bar, when the ow increases to ___ USGPM / L/s.
106
2011.2
Pressure Reducing
The maximum downstream pressure under any ow condition shall be ___ psi / ___ bar.
Assembly shall be according to Schematic A-8270E .
(i) Remote pressure locations shall remain relatively steady within a 35 psi / 2.4 bar increase.
(ii) The valve provides high pressure (adjustable) for periods of high demand but lower pressure
for off peak periods or periods of lesser demand. The valve shall reduce line leakage loss as
leakage loss is related directly to pressure.
Refer to Main Valve section, page 11, 106-PG or 206-PG for detailed information pertaining to
valve sizes and materials, selection criteria and specications. Model PFC Actuator specication
information is available from Singer Valve.
Ordering Instructions
Refer to page 286 for the order form and ordering instructions.
Additionally, include the following information for this product:
1. Full port (106) or reduced port (206)
2. Outlet pressure range
3. Minimum / maximum ow rate
4. Pressure increase at high ow
Flow Capacity
(See 106-PG in Main Valve section for other valve data)
106-PFC
Size (inches)
3 in
4 in
6 in
8 in
10 in
12 in
14 in
16 in
20 in
24 in
36 in
80 mm
100
mm
150
mm
200
mm
250
mm
300
mm
350
mm
400
mm
500 mm
600 mm
900
mm
10
20
40
10
10
20
0.3
0.6
1.3
2.5
0.1
0.1
0.2
0.2
0.2
0.2
0.6
0.6
0.6
460
800
1800
3100
4900
7000
8500 11000
17500
25800
55470
29
50
114
196
309
442
536
1104
1628
3500
Size (mm)
Minimum Continuous (USGPM)
Flat Diaphragm
Minimum Continuous (USGPM)
Rolling Diaphragm
Minimum Continuous (L/s)
Flat Diaphragm
Minimum Continuous (L/s)
Rolling Diaphragm
694
Flow Capacity
(See 206-PG in Main Valve section for other valve data)
206-PFC
Size (inches)
4 in
6 in
8 in
10 in
12 in
16 in
18 in
20 in
24 x 16 in 24 x 20 in
28 in
30 in
32 in
36 in
Size (mm)
100
mm
150
mm
200
mm
250
mm
300
mm
400
mm
450
mm
500
mm
700
mm
750
mm
800
mm
900 mm
10
20
40
10
10
10
10
0.3
0.6
1.3
2.5
0.2
0.2
0.2
0.2
0.2
0.2
0.6
0.6
0.6
0.6
580
1025
2300
4100
6400
16500
21700
37
65
145
259
404
582
1040
1370
2120
2011.2
1040
1040
2123
2126
2132
www.singervalve.com
107