Вы находитесь на странице: 1из 36

Program Book/Guidelines for

Eaton Vickers Hydraulics

Document: CL - F - Eaton Vickers Hydraulics


Version G1.2

Original Date: 09-15-2009


Revised Date: 1-1-2014

Page No.: 2 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

Document Management Information

The controlled version of this document is the one stored on the GMPT Machinery and Equipment Specifications web
site. Any printed copy is an uncontrolled copy. The user shall verify with the web site that he/she is in fact using the
appropriate version of the specification for the specific project he/she is working on.
Any questions or comments with respect to this specification should be directed to the project engineer for the specific
project in question.
Revision Date
09-15-2009

Version
No.
G 1.0

Document Name
CL-F-Eaton Vickers

10-20-2010

G 1.1

CL-F-Eaton Vickers

1-1-2014

G 1.2

CL-F-Eaton Vickers

Revision
Version G 1.0 prepared to comply with GMs
Global Hydraulic Specification SP-F Hydraulic
Contacts for Japan updated. Pilot operated
proportional relief valve (KBCG5-3) list added.
Added Walterscheid WALring tube fittings and
aeroquip hose. Added Hansen brand couplers

Paragraph
Affected
All
2.1, 2.2, 3.5.1
3.11, 3.12,
3.13, 3.14

Revised By
Eaton-Vickers
Eaton-Vickers
Joe Raccosta

Page No.: 3 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date: 1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

Table of Contents
1.0

INTRODUCTION .......................................................................................................................................................... 4

1.1

SCOPE OF DOCUMENT .............................................................................................................................................. 4

2.0

PROJECT CONTACT INFORMATION ........................................................................................................................ 4

2.1
2.2

MANAGEMENT CONTACTS ....................................................................................................................................... 4


SERVICE AND SUPPORT CONTACTS ....................................................................................................................... 5

3.0

PRODUCT OVERVIEW ................................................................................................................................................ 6

3.1
HYDRAULIC POWER UNITS. ...................................................................................................................................... 7
3.1.1
Vertical in tank Power Units. .................................................................................................................................. 7
3.1.2
Overhead / L shaped Power Units. ........................................................................................................................ 9
3.1.3
Horizontal Power Units ........................................................................................................................................ 11
3.1.4
Compact Power Units. ......................................................................................................................................... 13
3.1.5
In-Line Pressure Filters....................................................................................................................................... 14
3.1.6
In - Tank Return Filters ....................................................................................................................................... 16
3.1.7
Filter Electrical Indicators..................................................................................................................................... 18
3.2
DIRECTIONAL VALVES ............................................................................................................................................. 19
3.2.1
NG6 (D03) Four-Way Directional Control Valves ................................................................................................ 19
3.2.2
Single Stage NG10 (D05) Four-Way Directional Control Valves ......................................................................... 19
3.2.3
Two Stage NG10 (D05) Four-Way Directional Control Valves ............................................................................ 20
3.2.4
NG16 (D07) Four-Way Directional Control Valves .............................................................................................. 20
3.2.5
NG25 (D08) Four-Way Directional Control Valves .............................................................................................. 21
3.3
MODULAR SANDWICH VALVE. ................................................................................................................................ 22
3.3.1
NG6 (D03) Modular Sandwich Modules. ............................................................................................................. 22
3.3.2
NG10 (D05) Modular Sandwich Modules. ........................................................................................................... 23
3.3.3
NG16 (D07) Modular Sandwich Modules. ........................................................................................................... 25
3.3.4
NG25 (D08) Modular Sandwich Modules. ........................................................................................................... 26
3.4
INLINE CHECK VALVES. ........................................................................................................................................... 27
3.5
PROPORTIONAL VALVES......................................................................................................................................... 28
3.5.1
Proportional Pressure Controls............................................................................................................................ 28
3.5.2
Proportional Directional Valves ............................................................................................................................ 28
3.6
ACCUMULATORS 13.2 GALLONS (1 50 LITERS) ................................................................................................. 29
3.7
ACCUMULATOR SAFETY BLOCKS .......................................................................................................................... 30
3.8
SUB PLATES .............................................................................................................................................................. 31
3.9
MANIFOLDS ............................................................................................................................................................... 31
3.9.1
Cover Plates ........................................................................................................................................................ 32
3.10
CYLINDERS ............................................................................................................................................................ 33
3.11
WALTERSCHEID WALRING TUBE FITTINGS, AEROQUIP HOSE AND HANSEN COUPLERS ........................ 35
3.12
WALTERSCHEID WALRING TUBE FITTINGS ...................................................................................................... 35
3.13
AEROQUIP HOSE.................................................................................................................................................. 35
3.14
HANSEN COUPLERS ............................................................................................................................................. 36

Page No.: 4 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

1.0 INTRODUCTION
1.1

SCOPE OF DOCUMENT

The Program Book provides a list of Eaton Vickers Hydraulic Products to be used for new GMPT Programs. The use
of components not listed in the Program Book requires a deviation from GMPT Controls Engineering. For the
complete Hydraulic System requirements see GMPT Specification SP-F-Hydraulics.

2.0 PROJECT CONTACT INFORMATION


2.1

MANAGEMENT CONTACTS
NORTH AMERICA
Eaton Corporation

Address

54249 Shady Lane

BRAZIL

EUROPE

Eaton Corporation
Av. Julia Gaioli, 450
Bonsucesso

APAC / CHINA

Eaton Corporation
Am Joseph 16

Eaton Corporation
300 Huai Hai Zhong Rd.
th
11 Floor

Wehrheim, Germany DShanghai 200021


61273

Shelby Twp.

Guarulhos

MI 48315

www.eaton.com

www.eaton.com

Website
Project
Contact
Company

www.eaton.com

So Paulo 07250-270
Brazil
www.eaton.com

Joe Raccosta

Antunes, Alvaro A

Armin Steinmann

Vivian Wan

Office

586-232-4942

55-11-2465-8815

+49-(0) 172 6026-821

+86-21-6387-9988 Ext
712

Mobile

586-292-1557

Fax
E-Mail

josephsraccosta@eaton AlvaroAAntunes@eaton. ArminSteinmann@eaton VivianWan@eaton.com


.com
com
.com
JAPAN

Address

Website
Project
Contact
Company
Office
Mobile
Fax
E-Mail

KOREA

INDIA

Eaton Corporation
Uruma Kowa Bldg.,
8-11-37, Akasaka,
Minato-ku, Tokyo
Japan
www.eaton.com

Eaton Corporation
Seoul
Korea

Eaton Corporation
54249 Shady Lane.
Shelby Twp.
MI 48315

www.eaton.com

www.eaton.com

Hirokazu Nishida

DooWhan Kim

Joe Raccosta

+81 35-786-2560
+81 90-9882-5031

(822)562-3870

586-232-4942
586-292-1557

DooWhanKim@eaton.com

josephsraccosta@eaton.com

+81 3-5786-2561
HirokazuNishida
@eaton.com

Page No.: 5 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

2.2

SERVICE AND SUPPORT CONTACTS


NORTH AMERICA

BRAZIL

EUROPE

APAC/CHINA

Company

Eaton Corporation

Eaton Corporation

Eaton Corporation

Eaton Corporation

Address

2668 Pine Ridge Rd.

Av. Julia Gaioli, 450


Bonsucesso

Am Joseph 16

388 AiDu Rd.

West Bloomfield, MI
48324-1957

So Paulo 07250-270

Wehrheim, Germany
D-61273

Wai Gao, Shanghai


200131

www.eaton.com

www.eaton.com

Armin Heyer
+49 (0) 6081 103-340

Jason Lin
+86-21-3850-3303

Website

www.eaton.com

Local Support Duane Jaros


248-681-2990
Office
313-910-8036
Mobile

Guarulhos Brazil
www.eaton.com
Antunes, Alvaro A
55-11-2465-8815

Fax
E-Mail

DuaneAJaros@eaton.c AlvaroAAntunes@eaton
huiqiangwang@eaton.c
arminheyer@eaton.com
om
.com
om

JAPAN
Address

Website
Project
Contact
Company
Office
Mobile
Fax
E-Mail

KOREA

INDIA

Eaton Corporation
Uruma Kowa Bldg.,
8-11-37, Akasaka,
Minato-ku, Tokyo
Japan
www.eaton.com

Eaton Corporation
Seoul
Korea

Eaton Corporation
145 Off Mumbai-Pune Road
Pune 411018
INDIA

www.eaton.com

www.eaton.com

Hirokazu Nishida

DooWhan Kim

Suneel Patil

+81 35-786-2560
+81 90-9882-5031

(822)562-3870

+91-20-3061-1026
+91-976-5567060

DooWhanKim@eaton.com

SuneelBpatil@eaton.com

+81 3-5786-2561
HirokazuNishida
@eaton.com

Program Book / Guidelines for


Eaton Vickers Products

Page No.: 6 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

3.0 PRODUCT OVERVIEW


Eaton components required for GMPT are listed below. For more information, visit our website.
Product Main page
: http://hydraulics.eaton.com/products/menu_main.htm
Direction Control Valves
: http://www.eaton.com/ecm/groups/public/@pub/@eaton/@hyd/documents/content/pll_1634.pdf
Pressure Control
:http://www.eaton.com/Eaton/ProductsServices/Hydraulics/Valves/IndustrialValves/index.htm
Filters
: http://www.eaton.com/ecm/groups/public/@pub/@eaton/@hyd/documents/content/pll_1225.pdf
Stack Valves
:
:http://www.eaton.com/ecm/groups/public/@pub/@eaton/@hyd/documents/content/pll_1901.pdf
Accumulators
: http://www.eaton.com/ecm/groups/public/@pub/@eaton/@hyd/documents/content/pll_1224.pdf
Prop.Direction Control Valve
::
:http://www.eaton.com/ecm/groups/public/@pub/@eaton/@hyd/documents/content/pll_2104.pdf
:http://www.eaton.com/ecm/groups/public/@pub/@eaton/@hyd/documents/content/pll_2095.pdf

Page No.: 7 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.1

HYDRAULIC POWER UNITS.

GMPT Global Specification SP-F-Hydraulic lists three preferred styles of power units where the design provides for
flooded pump inlets. The three preferred power unit styles are: (1) Vertical with the pumps being submersed in the
reservoir (2) L Shaped where the pump-motor assembly is mounted to a base next to the reservoir and (3)
Overhead where the pump/motor assembly is mounted under the reservoir. An alternative Horizontal power unit
where the pump-motor assembly is mounted on top of the reservoir may be used provided that three design
considerations listed in the GMPT Hydraulic specification have been met. A synopsis of the tree design
considerations for power unit sound level, plant elevation and fluid viscosity is provided in section 3.1.3. All Power
units for GMPT must meet a sound specification of 75 dB(A) maximum.
GMPT hydraulic specification paragraph 8.2.2.9 states that the interior of reservoirs should not be painted. GMPT will
approve the interior painting of reservoirs when the system is operating on mineral oil. For GMPT Casting plants, the
machine builder must confirm the hydraulic fluid selection with the applicable plant. Systems operating with the fire
resistant fluids will require lower operating temperatures. In addition, the fluid selection may require that the reservoir
interior not be painted but coated with a rust preventative.
GMPT encourages the design of energy efficient hydraulic systems, which do not require heat exchangers.
3.1.1 Vertical in tank Power Units.
The Vertical power units for GMPT are available in four standard sizes, 100, 250, 400 & 800-Liter reservoirs. The
power unit will employ a thru-drive PVM/PVQ variable volume piston pump for main system flow with V series fixed
displacement vane pump for the Re-circulation / Filtration loop. Should a heat exchanger be required for a specific
application, a plate style heat exchanger will be added in the re-circulation line. For GMPT maintenance, purposes the
pump case drain line will access through the reservoir removable top plate and then connected to the return side of
the reservoir. The clean out covers are fixed with a minimum of six studs to prevent cover leakage. Power units will
be supplied with c isolation / level pads. If a heat exchanger is required for an application, a Plate style exchanger will
be part of the re- circulation loop. In addition, should an accumulator be required for certain application, it will be
added to the power unit along with the required lockable accumulator isolation block.

SIZE

100 LITER

1000 mm

700 mm

1200 mm

250 LITER

1060 mm

850 mm

1450 mm

400 LITER

1400 mm

950 mm

1750 mm

800 LITER

1700 mm

1150 mm

2100 mm

Page No.: 8 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

Power units for special machine applications, such as for long clamping cycles should be equipped with a heat
exchanger in the re-circulation line.

Sound Spec: Less than 75 dB(A)

Ports: ISO 1179-1 (G thread)

Fill point: H6-63 BSPP

Labels: Per GM Spec.

Main Pump, Var.


Displacement
Theo.Flow @ 1000
RPM
Theo.Flow @ 1200
RPM
Theo. Flow @1500
RPM
Pump Drive Speed
Electric Motor
Aux Pump for
Filtering/Cooling
Loop

Options: Accumulator circuit, heat exchanger circuit


Tubing & Fittings: Trivalent Chrome metric tubing &
metric flareless fittings per GM spec.
400L
800 L

100 L

250 L

PVM018ER17DS05A
AC2314000A00A

PVM045ER17DS08AAC23
14000A00A

PVM081ER18FS08AAC231
4000A00A

PVM131ER18HS08AAC2
314000A00A

18.0 LPM

45.0 LPM

80.9 LPM

131.0 LPM

21.6 LPM

54.0 LPM

97.1 LPM

157.3 LPM

27.0 LPM

67.6 LPM

121.4 LPM

196.6 LPM

The electric motor drive speeds for the regions are 1000 RPM for Europe, 1200 RPM for North America, 1500
RPM for China, Asia and South America. For China, Asia and South America 1500 RPM electric motors should
be used unless the max. Sound level of 75dB(A) cannot be achieved. In this case, 1000-RPM electric motors
may be used; however, the GM country unit must be consulted.
The machine builder should confirm the G.M. plant location to determine the exact motor voltage requirements.
V101S5S11A20

V201S11S62A11

V201S11S62A11

V201S11S62A11

DIN Return Filter

DRT 1 063 BC 4 XX N
B C 06 /w VR2LZ. 0 /
BO Dual Elec Indicator

DRT 1 160 BE 4 XX N B
C 06 /w VR 2 LZ. 0 / BO
Dual Elec Indicator

DRT 1 250 BF 4 XX N B C
06 /w VR 2 LZ. 0 / BO
Dual Elec Indicator

DRT 1 630 BM 4 XX N B C
06 /w VR 2 LZ. 0 / BO
Dual Elec Indicator

Filter Element

VDT 063 B C 06

VDT 160 B C 06

VDT 250 B C 06

VDT 630 B C 06

Return Filter

DIN Filters should be used for all regions except North America. For North America HF4 series return filters
should be used.

Temp. Switch

TR7430

TR7430

TR7430

TR7430

Level Switch
Pressure Switch

LK7023
PN7001

LK7023
PN7001

LK7023
PN7001

LK7023
PN7001

Page No.: 9 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.1.2

Overhead / L shaped Power Units.

Both Overhead and L Shaped power units provide the pumps with flooded inlets. The power unit will employ
PVM/PVQ variable volume piston pump for main system flow and separate V series fixed displacement vane pump
for the Re-circulation / Filtration loop. The power unit is equipped with an independent offline filtration circuit. Both the
main pump and the offline pump have ball valves with prox. Switches. The main pump is equipped with a secondary
relief valve, check valve and pressure switch. The power unit is equipped with both dual level and dual temperature
switches. If a heat exchanger is required for an application, a Plate style exchanger will be part of the re- circulation
loop. In addition, should an accumulator be required for certain application, it will be added to the power unit along
with the required lockable accumulator isolation block. For special applications, please consult Eaton Vickers.

Sound Spec: Less than 75 dB(A)

Ports: ISO 1179-1 (G thread)

Fill point: H6-63 BSPP

Labels: Per GM Spec.

Options: Accumulator circuit, heat exchanger circuit


Tubing & Fittings: Trivalent Chrome metric tubing &
metric flareless fittings per GM spec.

Page No.: 10 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

100 L

160 L

250L

Main Pump, Variable


Displacement

PVM018ER17DS05AAC23140
00000A

PVQ32MBR00SENS21CG14D
21S3

PVM045ER18DS08AAC23140
00000A

Theo. Flow @1000 RPM


Theo. Flow @ 1200 RPM
Theo. Flow @ 1500 RPM

18.0 LPM
32.9 LPM
45.0 LPM
21.6 LPM
39.5 LPM
54.0 LPM
27.0 LPM
52.6 LPM
67.6 LPM
The electric motor drive speeds for the regions are: 1000 RPM for Europe, 1200 RPM for North
America, 1500 RPM for China, Asia and South America. For China, Asia and South America 1500
RPM electric motors should be used unless the max. Sound level of 75dB(A) cannot be achieved.
In this case, 1000-RPM electric motors may be used; however, the GM country unit must be
consulted.
The machine builder should confirm the G.M. plant location to determine the exact motor voltage
requirements.
DIN Filters should be used for all regions except North America. For North America HF4 series
return filters should be used.
TR7430
TR7430
TR7430
LK7023
LK7023
LK7023
PN7001
PN7001
PN7001

Pump Drive Speed

Electric Motor
Return Filter
Temperature Switch
Level Switch
Pressure Switch

Page No.: 11 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.1.3

Horizontal Power Units

Horizontal power units may be used for a GMPT provided that three design considerations have been met. The three
design considerations listed in GMs Global Hydraulic Specifications are:
A) Altitude: Horizontal power units may not be used when the plant elevation exceeds 1000 meters.
B) Sound level: The complete power unit sound level must be below 75 dB(A).
C) Fluid Viscosity: The hydraulic fluid viscosity required for the application must not cause pump cavitations.
Horizontal power units can be provided in a number of different reservoir sizes, 100, 160, 250 & 400 Liters.. The
power unit will employ a PVM/PVQ variable volume piston pump for main system flow and separate V series fixed
displacement vane pump for the Re-circulation / Filtration loop. If a heat exchanger is required for an application, a
Plate style exchanger will be part of the re- circulation loop. In addition, should an accumulator be required for certain
application, it will be added to the power unit along with the required.

SIZE

100 LITER

1035 mm

860 mm

1050 mm

160 LITER

1300 mm

800 mm

1100 mm

250 LITER

1450 mm

860 mm

1200 mm

400 LITER

1050 mm

950 mm

1350 mm

Page No.: 12 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

Sound Spec: Less than 75 dB(A)

Ports: ISO 1179-1 (G thread)

Fill point: H6-63 BSPP

Labels: Per GM Spec.

Options: Accumulator circuit, heat exchanger circuit


Tubing & Fittings: Trivalent Chrome metric tubing &
metric flareless fittings per GM spec.

100 L

160 L

250L

400L

Main Pump, Variable


Displacement

PVM018ER17DS05AAC2
314000000A

PVQ32MBR00SENS21
CG14D21S3

PVM045ER17DS08AA
C2314000000A

PVM081ER18FS08AA
C2314000000A

Theo. Flow @1000 RPM


Theo. Flow @ 1200 RPM
Theo. Flow @ 1500 RPM

18.0 LPM
32.9 LPM
45.0 LPM
80.9 LPM
21.6 LPM
39.5 LPM
54.0 LPM
97.1 LPM
27.0 LPM
52.6 LPM
67.6 LPM
121.4 LPM
The electric motor drive speeds for the regions are: 1000 RPM for Europe, 1200 RPM for North America,
1500 RPM for China, Asia and South America. For China, Asia and South America 1500 RPM electric
motors should be used unless the max. Sound level of 75dB(A) cannot be achieved. In this case, 1000RPM electric motors may be used; however, the GM country unit must be consulted.
The machine builder should confirm the G.M. plant location to determine the exact motor voltage
requirements.
DIN Filters should be used for all regions except North America. For North America HF4 series return
filters should be used.
TR7430
TR7430
TR7430
TR7430
LK7023
LK7023
LK7023
LK7023
PN7001
PN7001
PN7001
PN7001

Pump Drive Speed

Electric Motor
Return Filter
Temperature Switch
Level Switch
Pressure Switch

Page No.: 13 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.1.4

Compact Power Units.

For special applications such as clamping, a 40L vertical power unit is available. The use of the 40L compact
power unit requires the approval of General Motors Engineering. Please consult with Eaton Vickers for design
assistance. The vertical power unit is provided with a fixed displacement vane pump to charge a small
accumulator, the pump is then unloaded. The power unit is equipped with both dual level and dual
temperature switches. The system directional valves must be mounted by the OEM to the machine and not
located on the power unit.

L
B
H

SIZE
620 mm
420 mm
660 mm

Page No.: 14 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.1.5

In-Line Pressure Filters


In- Line Pressure (HF*)

FOR INDICATOR REF : 3.1.7

Page No.: 15 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

In-Line Pressure DIN

FOR INDICATOR REF : 3.1.7

Page No.: 16 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.1.6

In - Tank Return Filters

In-Tank (HF*)

FOR INDICATOR REF : 3.1.7

Page No.: 17 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

In-Tank DIN

FOR INDICATOR REF : 3.1.7

Page No.: 18 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.1.7

Filter Electrical Indicators.


Filter Series

Hydac Model code

Hydac Part Number

HF3P Pressure filters

VD 5 LZ. 0 / BO

01265195

DHP DIN Pressure filters

VD 5 LZ. 0 / BO

01265195

DRT DIN Tank top Return filters

VR 2 LZ. 0 / BO

012654422

HF4RT Tank top Return filters

VMF 2 LZ. 1 / BO

02074114

Page No.: 19 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.2

DIRECTIONAL VALVES

3.2.1

NG6 (D03) Four-Way Directional Control Valves

Subplate mounted, 24 V DC, NBR seals, M12 connector on each Sol., pin configuration: Pin 1 & 2 not used, Pin 3
0volt, Pin 4 24Volt.
Symbol

Model Number & Description


F6-DG4V-3-6C-M-KUPM4L-D7-H7-60
P = 30 Watts
F6-DG4V-3-6C-M-KUPM4L-D7-HL7-60
P = 18 Watts

F6-DG4V-3-6C208-M-KUPM4L-D7-H7-60
Soft shift, P = 30 Watts
F6-DG4V-3-33C-M-KUPM4L-D7-H7-60
P = 30 Watts
F6-DG4V-3-33C-M-KUPM4L-D7-HL7-60 P = 18
Watts

02-400431
02-400432
02-400433
02-400434
02-400435

F6-DG4V-3-33C208-M-KUPM4L-D7-H7-60
Soft shift, P = 30 Watts

02-400436

F6-DG4V-3-2A-M-KUPM4L-D7-H7-60
P = 30 Watts

02-400425

F6-DG4V-3-2A-M-KUPM4L-D7-HL7-60
P = 18 Watts

F6-DG4V-3-2A208-M-KUPM4L-D7-H7-60
Soft shift, P = 30 Watts
F6-DG4V-3-2N-M-KUPM4L-D7-H7-60
P = 30 Watts
F6-DG4V-3-2N-M-KUPM4L-D7-HL7-60
P = 18 Watts

3.2.2

Part Number

F6-DG4V-3-2A208-M-KUPM4L-D7-H7-60
Soft shift, P = 30 Watts
Single Stage NG10 (D05) Four-Way Directional Control Valves

02-400426
02-400427
02-400428
02-400429
02-400430

Subplate mounted, 24 V DC, NBR seals, M12 connector on each Sol., pin configuration: Pin 1 & 2 not used, Pin 3
0volt, Pin 4 24Volt.
Symbol

Model Number & Description

F6-DG4V4-016C-M-KUPM4L-D7-H-5-10
P = 45 Watts
F6-DG4V4-016C-M-KUPM4L-D7-HL-4-10
P = 30 Watts
F6-DG4V4-0133C-M-KUPM4L-D7-H-5-10
P = 45 Watts
F6-DG4V4-0133C-M-KUPM4L-D7-HL-4-10
P = 30 Watts
F6-DG4V4-012A-M-KUPM4L-D7-H-5-10
P = 45 Watts
F6-DG4V4-012A-M-KUPM4L-D7-HL-4-10
P = 30 Watts
F6-DG4V4-012N-M-KUPM4L-D7-H-5-10
P = 45 Watts

F6-DG4V4-012N-M-KUPM4L-D7-HL-4-10
P = 30 Watts

Part Number
02-400441
02-400442
02-400443
02-400444
02-400437
02-400438
02-400439
02-400440

Page No.: 20 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.2.3

Two Stage NG10 (D05) Four-Way Directional Control Valves

Subplate mounted, 24 V DC, P=18 Watts, NBR seals, M12 connector on each Sol., pin configuration: Pin 1 & 2 not
used, Pin 3 0volt, Pin 4 24Volt.
Symbol

Model Number

Part Number

F6-DG5V-5-6C-M-KUPM4L-D7-HL7-10

02-400447

F6-DG5V-5-33C-M-KUPM4L-D7-HL7-10

02-400448

F6-DG5V-5-2A-M-KUPM4L-D7-HL7-10

02-400445

F6-DG5V-5-2N-M-KUPM4L-D7-HL7-10

02-400446

3.2.4

NG16 (D07) Four-Way Directional Control Valves

Subplate mounted, 24 V DC, P=18 Watts, NBR seals, M12 connector on each Sol., pin configuration: Pin 1 & 2 not
used, Pin 3 0volt, Pin 4 24Volt.
Symbol

Model Number

Part Number

F6-DG5V-7-6C-M-KUPM4L-D7-HL7-10

02-400451

F6-DG5V-7-33C-M-KUPM4L-D7-HL7-10

02-400452

F6-DG5V-7-2A-M-KUPM4L-D7-HL7-30

02-400449

F6-DG5V-7-2N-M-KUPM4L-D7-HL7-30

02-400450

Page No.: 21 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.2.5 NG25 (D08) Four-Way Directional Control Valves


Subplate mounted, 24 V DC, P=18 Watts, NBR seals, M12 connector on each Sol., pin configuration: Pin 1 & 2 not
used, Pin 3 0volt, Pin 4 24Volt.
Symbol

Model Number

Part Number

F6-DG5V-8-H-6C-M-KUPM4L-D7-HL7-10

02-400455

F6-DG5V-8-H-33C-M-KUPM4L-D7-HL7-10

02-400456

F6-DG5V-8-H-2A-M-KUPM4L-D7-HL7-10

02-400453

F6-DG5V-8-H-2N-M-KUPM4L-D7-HL7-10

02-400454

Note: To be used for clamping applications only. Other applications require written approval from GMPT Controls
Engineering

Page No.: 22 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.3

MODULAR SANDWICH VALVE.


3.3.1

NG6 (D03) Modular Sandwich Modules.


Symbol

Model Number & Description

Part Number

Dual Flow control Module


Meter out
On port A & B.
DGMFN-3-Y-A1W-B1W-41

694411

Flow control Module


Meter out
On port B.
DGMFN-3-Y-B1W-41

02-138526

Flow control Module


Meter out
On port A.
DGMFN 3 Y A1W 41

02-138527

Dual P.O. Check Module


On Port A & B
Pilot Ratio 3:1
DGMPC 3 ABK BAK 41

A Port P.O Check Module


On Port A
Pilot Ratio 3:1
DGMPC 3 ABK 41

B Port P.O Check Module


On Port B
Pilot Ratio 3:1
DGMPC 3 BAK 41
P Port Check Module
0.5 bar (8 psi) Spring
DGMDC 3 Y PK 41

694400

870024

870023

694415

P Port Pressure Reducing / Releiving Module


30 bar max.DGMX23PPAWB40

870021

80 bar max. DGMX23PPBWB40

870036

120 bar maxDGMX23PPCWB40

870037

Page No.: 23 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

A Port Pressure Reducing / Releiving Module


80 bar max. DGMX23PABWB40

870031

120 bar maxDGMX23PACWB40

870032

B Port Pressure Reducing / Releiving Module


80 bar max. DGMX23PBBWB40

870047

120 bar maxDGMX23PBCWB40

8700267

P to T Pressure Relief Module


50 bar max DGMC 3 PT AW 41
02-108132
100 bar max DGMC 3 PT BW 41

02-147590

200 bar max DGMC 3 PT CW 41

870233

B to T Pressure Relief Module


50 bar max DGMC 3 BT AW 41

871703

100 bar max DGMC 3 BT BW 41

02-108538

200 bar max DGMC 3 BT CW 41

870257

A to T Pressure Relief Module

3.3.2

50 bar max DGMC 3 AT AW 41

02-138107

100 bar max DGMC 3 AT BW 41

02-138108

200 bar max DGMC 3 AT CW 41

02-139196

NG10 (D05) Modular Sandwich Modules.


Symbol

Model Number & Description

Part Number

Dual Flow control Module


Meter out
On port A & B.
DGMFN 5 Y A1W B1W 30

868884

Flow control Module


Meter out
On port B.
DGMFN 5 Y B1W 30

02-140612

Flow control Module


Meter out
On port A.
DGMFN 5 Y A1W 30

867334

Page No.: 24 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

Dual P.O. Check Module


On Port A & B
Pilot Ratio 3:1
DGMPC 5 ABK BAK 30

P.O. Check Module


On Port A
Pilot Ratio 3:1
DGMPC 5 ABK 30

P.O. Check Module


On Port B
Pilot Ratio 3:1
DGMPC 5 BAK 30

867364

867339

867340

P Port Check Module


1bar (15 psi)

867341

DGMDC 5 Y PK 30
T Port Check Module
1bar (15 psi)

867342

DGMDC 5 X TK 30
P Port Pressure Reducing / Releiving Module
50 bar max. DGMX2 5 PP AW B 30

879343

100 bar max. DGMX2 5 PP BW B 30

868314

200 bar max. DGMX2 5 PP FW B 30

880553

A Port Pressure Reducing / Releiving Module


50 bar max. DGMX2 5 PA AW B 30

879344

100 bar max. DGMX2 5 PA BW B 30

868316

200 bar max. DGMX2 5 PA FW B 30

02-101968

Page No.: 25 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

B Port Pressure Reducing / Releiving Module


50 bar max. DGMX2 5 PB AW B 30

880554

100 bar max. DGMX2 5 PB BW B 30

868317

200 bar max. DGMX2 5 PB FW B 30

02-145043

P to T Pressure Relief Module


50 bar : DGMC 5 PT AW 30

879341

100 bar : DGMC 5 PT BW 30

868650

200 bar : DGMC 5 PT FW 30

879342

A to T Pressure Relief Module


50 bar : DGMC 5 AT AW 30

02-336089

100 bar : DGMC 5 AT BW 30

868651

200 bar : DGMC 5 AT FW 30

02-149394

B to T Pressure Relief Module

3.3.3

50 bar : DGMC 5 BT AW 30

868651

100 bar : DGMC 5 BT BW 30

868652

200 bar : DGMC 5 BT FW 30

02-127594

NG16 (D07) Modular Sandwich Modules.


Symbol

Model Number & Description


Dual Flow control Module
Meter out
On port A & B.
DGMFN 7 Y A2W B2W 30

Dual P.O. Check Module


On Port A & B
DGMPC 7 ABK BAK 30

P.O. Check Module


On Port A
DGMPC 7 ABK 30

Part Number

02-413078

02-413103

02-413102

Page No.: 26 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

P.O. Check Module


On Port B
DGMPC 7 BAK 30

3.3.4

02-413106

NG25 (D08) Modular Sandwich Modules.


Symbol

Model Number & Description

Dual Flow control Module


Meter out
On port A & B.
DGMN H8 Y A2W B2W 30

Part Number

02-413088

Dual P.O. Check Module


On Port A & B
DGMPC H8 ABK BAK 30

02-413055

P.O. Check Module


On Port A
DGMPC H8 ABK 30

02-413112

P.O. Check Module


On Port B
DGMPC H8 BAK 30

02-413114

Page No.: 27 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.4

INLINE CHECK VALVES.

DT8P1-02-05-10-UB
DT8P1-02-30-10-UB

0.3 bar (5 psi )cracking, G


2 bar(30 psi) cracking, G

Flow in
lpm
12
12

DT8P1-03-05-10-UB
DT8P1-03-30-10-UB

0.3 bar (5 psi )cracking, G 3/8


2 bar(30 psi) cracking, G 3/8

30
30

465451
465605

DT8PI-06-05-11-ENB
DT8PI-06-30-11-ENB

0.3 bar (5 psi )cracking, G


2 bar(30 psi) cracking, G

76
76

796127
796131

DT8PI-10-05-11-ENB
DT8PI-10-30-11-ENB

0.3 bar (5 psi )cracking, G1


2 bar(30 psi) cracking, G 1

190
190

796133
796137

Model Code

Cracking Pressure , Port Size

Part Number
796121
796125

Waltersheid Check valve


Model Code
RS 8 S
RS 10 S
RS 16 S
RS 20 S
RS 25 S
RS 30 S
RS 38 S

Cracking Pressure , Pipe Size


0.5 bar(7 psi) cracking, 8 mm OD
0.5 bar(7 psi) cracking, 10 mm OD
0.5 bar(7 psi) cracking, 16 mm OD
0.5 bar(7 psi) cracking, 20 mm OD
0.5 bar(7 psi) cracking, 25 mm OD
0.5 bar(7 psi) cracking, 30 mm OD
0.5 bar(7 psi) cracking, 30 mm OD

Flow in lpm
20
30
50
150
150
200
200

Part Number
067401 + 032431
067402 + 032431
025190 + 032438
067404 + 032445
067405 + 032445
067406 + 032451
067407 + 032457

Page No.: 28 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.5

PROPORTIONAL VALVES

3.5.1

Proportional Pressure Controls

Direct Operated, Max. Flow 5 L/min, with On-Board Electronics (OBE)


Size
Description
Model Number
NG6 (D03)

100 bar
160 bar
250 bar

Part Number

KBCG-3-100-DZM1-2-A-PE7-H1-10

02-352464

KBCG-3-160-DZM1-2-A-PE7-H1-10

02-352465

KBCG-3-250-DZM1-2-A-PE7-H1-10

02-354566

Electrical Connector

934939

Pilot Operated, Max. Flow 40 L/min, with On-Board Electronics (OBE)


Size
Description
Model Number

Part Number

NG6 (D03)

100 bar
160 bar
250 bar

KBCG5-3-100D-Z-T-M1-4-A-PE7-H1-10

02-413924

KBCG5-3-160D-Z-T-M1-4-A-PE7-H1-10

02-413925

KBCG5-3-250D-Z-T-M1-4-A-PE7-H1-10

02-413926

Electrical Connector

3.5.2

934939

Proportional Directional Valves

Direct Operated with On-Board Electronics (OBE)


Size

Description

Model Number

Part Number

NG6 (D03)

13L/min

KBFDG4V-3-33C13N-Z-M1-PE7-H7-11

5995984-001

32L/min

CONSULT EATON

Electrical Connector

934939

Size

Description

Model Number

Part Number

NG610 (D05)

50L/min

KBFDG4V-5-33C50N-Z-M1-PE7-H7-11

5996181-001

80L/min

CONSULT EATON

Electrical Connector

934939

Page No.: 29 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.6

ACCUMULATORS 13.2 Gallons (1 50 Liters)

Diaphragm Type Accumulators


Volume

Pressure
Rating

Ports
ISO 1179-1
G thread

Hydac Model Code

1 Liter

210 bar

SB0 210 1 E1 /112 ** 210 AK

Bottom Repairable Bladder Accumulators


Volume

Pressure
Rating

Ports
ISO 1179-1
G thread

Hydac Model Code

4 Liter

330 bar

G 1

SB 330 4 A1 / 112 ** 330 A

6 Liters

330 bar

G 1

SB 330 6 A1 / 112 ** 330 A

10 Liters

330 bar

G2

SB 330 10 A1 / 112 ** 330 A

20 Liters

330 bar

G2

SB 330 20 A1 / 112 ** 330 A

32 Liters

330 bar

G2

SB 330 32 A1 / 112 ** 330 A

50 Liters

330 bar

G2

SB 330 50 A1 / 112 ** 330 A

Above 50
liters
Accessories

Use Piston Accumulators. Consult Eaton for further Details


Volume

Qty

Part Number

Clamp

1 ltr

100AV00048A

Clamp

4 6 ltr

100AV00041A

Clamp

10 ltr

100AV00042A

Clamp

20 50 ltr

100AV00042A

Support Bracket w/ Ring

4 6 Liters

100AV00054A

Support Bracket w/ Ring

1032 Liters

100AV00055A

Charging kit

100AV00093A

** Note: The accumulator model codes may require a different suffix code dependant upon the country where the
accumulator is being shipped. For the U.S. and Mexico this is an ASME suffix code, Ontario Canada requires ASME
plus TSSA certification, CE for Europe, SELO for China and NR-13 for Brazil. Other countries may have different
certification requirements and the suffix code may change. Please check with Eaton Vickers for the requirements of
the final destination country.

Page No.: 30 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.7

ACCUMULATOR SAFETY BLOCKS


Required per
GM spec.
The Accumulator Safety Blocks are used for safety, isolation
and unloading of hydraulic accumulators. GMPT specifications
require a safety block to be provided for each accumulator
application. Each safety block is equipped with a manual
isolation valve with locking handle, manual unloading valve,
safety valve and a 24 V solenoid unloading valve.

Accumulator Size

Size Model Code

Ports
ISO 1179-1
G thread

Part Numbers

1 Liter

NG 10 ESS 10E 16Y1-N250A-S30- L

G 1/2

100AV00169A

4 to 6 Liters

NG 10 ESS 10E 16Y1-N250A-S12- L

G 1

100AV00170A

10 to 20 Liters

NG 20 ESS 20E16Y1-N250A-S13- L

G2

100AV00171A

34 to 50 Liters

NG 32 ESS 32E16Y1-N250A-S309- L

G2

100AV00172A

Accessories Part Number


DIN-M12 Connector
Equipped with Z diode and indicator light
(DIN to M12 adapter to be added)

Part Number
VAG-029-3401 ( MENCOM )

Page No.: 31 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.8

SUB PLATES
Steel or Ductile Iron Subplates with Metric Threads for Valve Bolt Down

Valve Pattern

Port ISO 228 #

MODEL CODE

Description

Part Numbers

NG6(D03)

G 3/8

DGVM 3 10 R

Bottom Ported

466730

NG10 (D05)

E DGSM 01Y 10 R

Bottom Ported

711921

NG16(D07)

G 3/4

E DGVM 7X D 10 R

Bottom Ported w/ X & Y Ports

984617

NG25(D08)

G1

E DGVM 8X D 10 R

Bottom Ported w/ X & Y Ports

788298

3.9

MANIFOLDS
Ductile Iron Manifolds with Bottom and Side Ports and Metric Valve Bolt Down Threads
SIZE

NG6(D03)

Ports

Nr. Of Stations

MODEL CODE

A&B: G
P&T : G
A B Test Points G1/4
ISO 228 Ports
P & T : Both Ends
A& B : Bottom Face
Test Points : One on each side

PREMIUM - 3 2 LPR BP

PREMIUM - 3 3 LPR BP

PREMIUM - 3 4 LPR BP

PREMIUM - 3 5 LPR BP

PREMIUM - 3 6 LPR BP

PREMIUM - 3 7 LPR BP

Alternate manifolds (For North America or as requested by other regions)


A&B: G 3/4
P&T : G1
A B Test Points G1/4
ISO 228 Ports
P & T : Both Ends
A& B : Bottom Face
Test Points : One on each side

DD03HPB023B

DD03HPB033B

DD03HPB043B

DD03HPB053B

DD03HPB063B

DD03HPB073B

Page No.: 32 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

Ductile Iron Manifolds with Bottom and Side Ports and Metric Valve Bolt Down Threads
SIZE

NG10 (D05)

Ports

Nr. Of Stations

MODEL CODE

A&B: G 1
P:G
T:G1
A B Test Points G1/4
ISO 228 Ports
P & T : Both Ends
A& B : Bottom Face
Test Points : One on each side

MR K - 5 - 2 G

MR K - 5 - 3 G

MR K - 5 - 4 G

MR K - 5 - 5 G

MR K - 5 - 6 G

Alternate manifolds (For North America or as requested by other regions)


A&B: G 3/4
P&T : G 1
A B Test Points G1/4
ISO 228 Ports
P & T : Both Ends
A& B : Bottom Face
Test Points : One on each side

3.9.1

DD05HPB023B

DD05HPB033B

DD05HPB043B

DD05HPB053B

DD05HPB063B

Cover Plates

Valve Pattern

Description

NG6 (D03)

Cover Plate with


Metric Bolts & O
Rings

NG10 (D05)

Cover Plate with


Metric Bolts & O
Rings

NG6 (D03) NG10(D05)

D05(NG10) Adapter
with Metric Bolts &
O Rings

Model code
MR C - 3 PA
Alternate for North America or as requested by other regions
D D03 COP G M
MR C - 5 PA
Alternate for North America or as requested by other regions
D D05 COP G M
MR A - 5 / 3
Alternate for North America or as requested by other regions
D D03 D05 VA AB M

Page No.: 33 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

3.10

CYLINDERS
METRIC / ISO CYLINDERS

SAMPLE MODEL CODE:


IHMAD-80X100X-N-36-2-G-H-B-1-1-X

Program Book / Guidelines for


Eaton Vickers Products

Gland Drain Options:


Gland drains are primarily used for long stroke cylinders
(over 1 m) when extend speed exceeds retract speed.
The Gland drain is used to return any accumulated fluid,
between the rod seal and wiper, to tank. This is used in
servo applications for ultra low leakage requirements or
for remote visual monitoring of rod seal leakage for
preventive maintenance purpose.

Page No.: 34 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Program Book / Guidelines for


Eaton Vickers Products

Page No.: 35 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

3.11 WALTERSCHEID WALRING TUBE FITTINGS, AEROQUIP HOSE AND HANSEN COUPLERS
3.12 WALTERSCHEID WALRING TUBE FITTINGS

3.13 AEROQUIP HOSE


Data sheet: refer to hose catalogue

Program Book / Guidelines for


Eaton Vickers Products

3.14 HANSEN COUPLERS


Data sheet: ISO 7241-1 series B

Page No.: 36 of 36
Document No.: CL-F-Eaton Vickers
Version G 1.2
Original Date: 09-15-2009
Revised Date:1-1-2014

Вам также может понравиться