SWIMMING POOL CALCULATION (AS SUBMISSION 08/04/2013)

APPROXIMATE DIMENSION
MALE POOL
AREA
TOTAL
FEMALE POOL
TOTAL
WADING POOL

MALE
FLOWRATE

123 HEIGHT
52
62
38

1.2
0.9

19

0.6

6 HOUR RECIRCULATION
194.4 M3
32.4 M3/HR
118.9 IGPM

FLOWRATE INLET
FEMALE
FLOWRATE

85.25 IGPM

TOTAL
185.3 IGPM
187.55 IGPM
WADING
FLOWRATE

SKIMMER PIPE

DIA

NOZZLE FLOWRATE
24
8.525

VELOCITY
MALE + FEMALE + WADING P
VELOCITY
DIA
AREA
FLOWRATE
VELOCITY

2 HOUR RECIRCULATION
11.4 M3
5.7 M3/HR
20.9 IGPM

FLOWRATE INLET

PUMP RATE
465
465
930
204.6

102.3 IGPM

6 HOUR RECIRCULATION
108.6 M3
18.1 M3/HR
66.427 IGPM

FLOWRATE INLET

1.2 VOLUME
0.9

17.05 IGPM
30 IGPM
0.002274 M3/S
0.5 M/S
0.004548 M2
0.076097 M

VELOCITY RETURN PIPE


2 NOS 100mm
204.6
102.3
100
0.007854
0.007754
0.987313

76.09661 MM
63 MM/(1 M/S)

147.6 M3
46.8 M3
194.4 M3
74.4 M3
34.2 M3
108.6 M3
11.4 M3

UMP RATE
L/MIN
L/MIN
L/MIN
IGPM

DUTY 1
DUTY 2
TOTAL
TOTAL

OZZLE FLOWRATE
NOS
IGPM/NOS

MALE + FEMALE + WADING PER NOZZLE


NOT EXCEED 3M/S
50 MM
0.001963495 M2
0.0 M3/S
0.3 M/S

ELOCITY RETURN PIPE


NOS 100mm
IGPM
IGPM/PIPE
MM
M2
M3/S
M/S