The LNG fuel system consists of the cylinder (fluid reservoir), vaporizer, line regulator, buffer tank, pressure
building pipeline and other systems.
The LNG cylinder (fluid reservoir) is a cryo-insulation pressure vessel which can be used to multiply fill a gas.
With the double-layer vacuum insulation structure, the reservoir consists of the inside liner, housing, insulating layer,
valves and etc. The natural gas is stored in the low-temperature low-pressure vacuum insulation reservoir with
the form of liquid-state, the inside temperature of the fluid reservoir is generally between -138 and -162,
and the normal operating pressure of the cylinder shall be no more than 1.89MPa.
Vaporizer: The LNG gas shall be vaporized by the vaporizer to the CNG gas after its temperature rises, and
then the CNG gas is supplied to the engine. Much more heat will be absorbed during vaporization. The
vaporizer uses the engine circulating coolant to heat and vaporize the liquefied natural gas (LNG), and thus
make the natural gas meet the engine operating temperature and flowrate requirements.
The main function of the line regulator is to decrease the pressure of natural gas after vaporized by the
vaporizer and lower the pressure down to the set pressure of the pressure stabilizer so as to ensure that the
pressure of gas entering into the engine meets the operating requirement.
The function of the buffer tank is to store a certain amount of gas in the tank, and provide the additional gas
consumption if the higher gas consumption (e.g., high power required) is required while the vaporized gas is
insufficient, which avoids the shortage of gas supply.
For the LNG supply system, the gas supply and pressure will directly affect the engine performance and its
operating reliability.
The schematic diagram of a LNG system:
Page 1 of 7 pages
In the LNG system, the symbol, name and function description for its functional parts are as follows:
Symbol
Function description
C1
C2
Vv
Vu
Va
Vaporizer
FCv
DCv
Er
Economizer regulator
It is used to preferentially use the gas and thus ensure the pressure
inside the cylinder. The set value 0.9MPa
Ef
P1
P2
PBr
DYJ-06A
DL-06-10
DYS-06A1
It is used to prevent the excessive outflow of the LNG gas from the
cylinder when the external pipeline is loss of pressure.
Pr
Pv
LG
Svp
It is used to control the safety pressure inside the cylinder. The set
value 1.89MPa
Svs
LSv
LRe
Line Regulator
DYS-20 or DYS-15C
Cb
Convert Box
SV
Solenoid valve
DJ-10P5
Here, the operating principle of the LNG system isn't described in details.
Now, the common trouble diagnosis, possible cause analysis and troubleshooting for the LNG system are
summarized as follows:
Page 2 of 7 pages
Underpowered
Underpowered
Inspection Method
Possible Cause
Troubleshooting
Page 3 of 7 pages
Underpowered
Replace or tighten
Power unstable
normal;
The cylinder pressure gauge is
stable;
The pressure gauge of the buffer
tank fluctuates;
The pressure building coil is frosted;
The cylinder pressure gauge
fluctuates;
The pressure gauge of the buffer
tank fluctuates;
The pressure building coil is frosted;
The cylinder pressure gauge is
normal;
The pressure building coil is frosted;
The pressure gauge of the buffer
tank fluctuates;
The cylinder pressure gauge is
normal;
The pressure building coil is frosted;
The pressure gauge of the buffer
tank reduces in reading;
Page 4 of 7 pages
pressure
Page 5 of 7 pages
Normal
Page 6 of 7 pages
to
the
Page 7 of 7 pages