Академический Документы
Профессиональный Документы
Культура Документы
Group 1
Alejandro Lopez Perez
Dragana Stojanovic
Kostantinos Papanikolaou
Priyanka Vaiude
Eindhoven 27/3/2015
List of Acronyms
EPH
GLY
HCl
GTE
HOCl
1,3-DCP
2,3-DCP
NaOH
a-MCH
b-MCH
GLUA
DCP
PFD
HPS
LPS
MPS
AA
CAPEX
Epichlorohydrin
Glycerol
Hydrogen chloride
Glycerol to epichlorohydrin
Hypochlorous acid
1,3-dichloro propan-2-ol
2,3-dichloro propan-1-ol
Sodium hydroxide
a-Monochlohydrin
b-Monochlorohydrin
Glutamic acid
Dichloropropanols
Process flow diagram
High pressure steam
Low pressure steam
Medium Pressure steam
Adipic acid
Capital expenditure
OPEX
Operating expenditure
NaCl
Sodium chloride
CSTR
*DCPs are referred as dichlorohydrins in the text in some instances, expressing the same
compounds (1,3-DCP, 2,3-DCP).
Nomenclature
Units
r1
mol/m3 s
Gas constant
J/mol K
k1
mol s/m3
[OH-]
mol/m3
[EPH]
Concentration of EPH
mol/m3
[DCP]
Concentration of DCP
mol/m3
Temperature
k2
mol s/m3
r2
mol/m3 s
SGLY/1,3-DCP
Cp
kJ/kg K
Molar flow
kmol/s
FCp
kW/K
Qinterval
kW
Tinterval
NHE,AP
NHE,BP
NS,BP
NS,AP
TCW
hvap
Latent heat
kJ/kg
Qutility
kW
Cpo
CBM
FBM
Fm
FP
M&S
Executive Summary
Epichlorohydrin is a valuable fine chemical, mainly dedicated to the manufacturing of epoxy resins.
Currently, several routes are available for the production of this chemical with the predominant one
to be the allylic chlorination of propylene, referred also as conventional process route in this text.
The extensive formation of undesired chlorinated organics from this process that are difficult to be
disposed of and the escalating cost of petrochemical raw materials such as propylene postulate the
investigation of alternative routes for epichlorohydrin manufacturing.
The above disadvantages of the conventional process in combination with the growing availability of
glycerol, as consequence of the increase of biodiesel production have played decisive role in the
rapid development of the glycerol to epichlorohydrin route (known as GTE process) which was
historically prevented due to the high cost of glycerol.
GTE route is divided into two steps; chlorination of glycerol is the first and dehydrochlorination of
dichloropropanols the second one. In the present study both steps have been examined thoroughly
and the entire process has been simulated on Aspen Plus V8.6 software.
Two reactor configurations have been proposed for the first step, utilising adipic acid as a liquid
catalyst, whilst a reactive distillation column has been designed for the second step accompanied by
a separation train for production of almost 99% pure final product.
Sizing of process equipment and economic evaluation of the process have been performed, revealing
strong potential of GTE route compared to the conventional technology. China has been chosen as
the location of the plant and the payback period has been estimated to endure 3 years for 1800 $/ton
selling price of epichlorohydrin. Heat integration by Pinch point analysis showed 0.167 M$/year
savings from utilities and finally a preliminary control scheme has been suggested for the process.
Design Considerations
The basis of design considered in the current project is specified in this section. The topics
considered in the Basis of Design are the plant capacity, plant location, composition and prices of
materials (i.e. raw material), physical and chemical properties of the substances involved in the
process and storage information about some of these materials.
Plant capacity
The capacity of the GTE process in order to produce epichlorohydrin (EPH) is given to be 100
kton/year.
Plant location
Formula
Purity wt.%
Purchase price
Glycerol
C3H8O3
99.9
$/ton
800
Hydrogen
HCl
100
360
NaOH
99.99
120
chloride gas
Sodium
hydroxide
Table of Contents
1.
INTRODUCTION......................................................................................................................................2
2.
Literature Review.......................................................................................................................................5
3.
4.
5.
6.
2.1.
2.2.
2.3.
2.4.
3.2.
Dehydrochlorination of DCP............................................................................................................31
4.2.
4.3.
Economic evaluation................................................................................................................................41
5.1.
5.2.
Results..............................................................................................................................................42
Appendix..........................................................................................................................................................46
Heat Integration of GTE Process-Pinch Point Analysis....................................................................................49
GTE Heat Exchanger Network Design above Pinch Point...........................................................................52
GTE Heat Exchanger Network Design below Pinch Point...........................................................................54
Annual Savings Estimation...........................................................................................................................56
Control Scheme of GTE Process......................................................................................................................58
Control of Reactors.......................................................................................................................................58
Control of Distillation columns....................................................................................................................59
Heat Exchangers and Decanters...................................................................................................................59
References........................................................................................................................................................63
Introduction
1. INTRODUCTION
Several routes are known to manufacture EPH, most is made in a two-step process from allyl
chloride and hypochlorous acid procuring a mixture of two chlorinated alcohols which can be
converted into EPH by treating with a base sodium hydroxide.
In the different reactions occurring in the above process, large amount of undesired organic
compounds which are very expensive to be discarded resulting to a high required selling price. In
combination with the high price of propylene, which is used a raw material, this route of EPH
production becomes less attractive leading to a need for alternative routes.
Owing to the disadvantages mentioned above, other routes have been investigated and GTE is
highlighted as the most promising technology representing an economically and environmentally
advantageous process. The commercial development of the process was obstructed until recently,
because of the high cost of glycerol. The recent advances in the technology related to biofuels have
caused the GLY price to drop dramatically since it can be obtained as a biodiesel by-product. This
new development and subsequent reduction in prices of GLY has indicated a great potential for the
feasibility of GTE process.
In 2007 Solvay, a traditional GLY and EPH manufacturer was the first to start GTE process.
Previously in the early 2000s the company was producing GLY from EPH but after the glycerol price
drop, it reversed its process to produce EPH from GLY. The picture below taken from the company
website represents this reversal trend in the process of production of EPH and glycerol.
Figure 1.1 Trend reversal in the processes concerning Glycerol and EPH from Solvay.
Solvay has acquired many patents in this regard and the innovative process is registered as
Epicerol, characterized as the most important patented process for the production EPH. The
2
company claims that this process is very environment friendly and reduces the carbon footprint by
60% as compared to the conventional route. GTE process of EPH production has been patented by
other well-known chemical industries like DOW chemicals.
The aim of this project is the evaluation of technical as well as economic feasibility of GTE process
and comprehensive comparison with the conventional process. To that end, GTE process has to be
thoroughly designed with subsequent estimation of Capital Expenditure (CAPEX) and Operating
Expenditure (OPEX). ASPEN PLUS (version 8.2) will be used for that purpose and the efficiency of
GTE will be established.
Literature Review
2. Literature Review
EPH is a liquid epoxide being used as an intermediate chemical for the production of epoxy resins
for coatings paintings and electronic circuits but also for non-epoxy applications such as paper
chemicals, water treatment and health care products [1]. China is highlighted as the leading market in
EPH production. Almost 97 % of the annual production is being consumed in the production of
epoxy resins and ca. 5% increase in annual production rate is predicted until 2018 [2].
Many different routes for EPH manufacture have been suggested in the literature; however the
predominant one in industry is the allylic chlorination of propylene to allyl chloride, starting from
propylene and chlorine as primary raw materials in a multi-step process as indicating in Figure 2.1.
Figure 2.1 The conventional route to EPH production in a multi-step process [3].
The first reaction is the allylic chlorination of propylene to allyl chloride. In parallel hypochlorous
acid (HOCl) being produced via dissolving of chlorine into water and subsequently reacts with the
produced allyl chloride from the first step to yield a mixture of 1,3-dichloropropan-2-ol (1,3-DCP)
and 2,3-dichloropropan-1-ol (2,3-DCP). The last step of the process includes the reaction between
dichloropropanols (DCP) and a base (e.g. NaOH or Ca(OH) 2) for the formation of the final product.
The described process can yield EPH of very high purity but suffers from numerous undesirable
features such as very low chlorine atom efficiency (i.e. only one of the four chlorine atoms
participating in the reaction is retained in the product molecule), significant inefficiencies in the
chlorination and hypochlorination steps, resulting to the formation of unwanted chlorinated organics
5
(ca. 0.5t/tEPH) and finally the continuous increase in the cost of petrochemical raw material like
propylene. [4]. In order these problems to be addressed different routes were examined in the past
based on less expensive raw materials. One such a route relies on the conversion of GLY through
DCP to EPH, known as glycerine to epichlorohydrin process (GTE). The high cost of GLY prevented
the development and the consideration of this process previously. This situation has been changed
recently since GLY can be obtained as by-product of biodiesel production (ca. 0.1 tn/tn Biodiesel),
and investigation on this process being conducted extensively [5,6]. Figure 2.2 shows the rise in
biodiesel production from 2000 to 2008, implying the potential of GTE process in the near future.
2.1.
The first step of the process is the chlorination of GLY as mentioned previously, where four reactions
in series and parallel (i.e. complex reactions) are taking place. The reaction of GLY with HCl yields a
mixture of a-Monochlorohydrin (a-MCH) and 2-Monochlorohydrin (b-MCH) as indicated in Figure
2.5. Subsequently a-MCH reacts with HCl to produce the final product of the first step, i.e. DCP. All
the reactions involved in reaction network are reversible but kinetics studies have shown negligible
kinetic constants of the reverse reactions, thus they can be considered as irreversible.
Catalyst Selection
Catalyst Concentration
HCl state
Operating conditions
Reaction kinetics
E. Santacesaria [4] tested different carboxylic acids by using an apparatus operating in continuous
mode for HCl and batch for GLY in an effort to define catalysts with similar performance as acetic
acid but significantly lower volatilities. In this study the crucial role of pK a value in relation to the
performance of the catalyst was fortified. Specifically catalysts with pK a greater than 4 showed high
selectivity to DCP, while those with less than 1.2 demonstrated high selectivity to a-MCH and bMCH. The experiments were conducted at 100 oC and 5.5 bar HCl pressure and the downstream
composition was measured after 3 h. Adipic acid (AA) found to be very selective to 1,3-DCP, with
molar concentration of
combination with high boiling point of AA (337.5 oC) highlights it as a promising catalyst.
R. Vitello et. Al [5] performed experiments with two series of catalysts, specifically glycolic acid
series and amminoacid series. The runs conducted at 100 oC for different pressures of gaseous HCl
and different concentration of catalysts. Glutamic acid (GLUA) found to be the best one in terms of
performance and further investigation followed. Higher concentration of catalyst proved to be very
beneficial regarding the selectivity to the desired product as seen in Figure 2.6, as from 2% catalyst
loading to 8%, a rise of 40% to selectivity towards 1,3-DCP is noted.
Figure 2.6 Effect of catalyst loading in selectivity for GLUA catalyst at P=4.5bar and T=100 oC [5]
Propionic acid has been discussed as another alternative [6] but with no good perspective because of
its slightly lower volatility than AA.
Figure 2.7 Effect of water concentration to the reaction rate constant of a-MCP production [7].
Apparently, hydration degree strongly affects the reaction rates, resulting to smaller amount of
products formed and consequently to large reaction volumes. This problem can be tackled by feeding
gaseous HCl in the reactor. The feed pressure of HCl is a critical parameter as influences strongly the
conversion of GLY but also the selectivity toward 1,3-DCH which can react 20 times faster than 2,3DCP for EPH production.
10
Bruce M. et. al [3] demonstrated the effect of HCl pressure on product molar composition by
utilising 2 wt% acetic acid catalyst. Three different values of pressure were tested, 20, 30 and 50 psi.
The formation of 1,3-DCP in the case of 20 psi was observed to be negligible, while for 50 psi it has
the highest concentration in the reactor outlet. This behaviour can be explained by the reaction
nature. The reaction seems to be equilibrium limited at low HCl pressures resulting to very low
conversions and after 1 h run the concentrations of a-MCP and GLY reach a limit and no change can
be observed afterwards. Additionally, in the same study proved that the absorption of HCl to GLY is
higher working at higher pressures, indicating that higher conversion of GLY can be achieved.
Figure
2.8 demonstrates product evolution for different HCl pressures [3].
Similar results presented by R. Tesser et. al. [8] where monochloro-acetic acid catalyst tested under
2, 5.5 and 9 bar pressures. At 9 bar pressure complete conversion of GLY achieved after almost 3 hr
of experiment and 30 % rise of selectivity appeared after 225 min as shown in Figure 2.9.
11
Figure 2.9 Selectivity to dichlorohydrins (i.e. DCP) as a function of HCl partial pressure [8].
S.H. Lee et al. [9] highlighted the importance of proper mixing of the GLY and HCl for good yields
and selectivity. Experiments were conducted in a batch reactor revealing that at low stirrer speed
chlorination of GLY is mass transfer limited but above 600 rpm HCl is dissolved effectively in the
liquid phase providing higher yields of 1,3-DCP. This a critical observation that should be taken into
account for the reactor design and proper mixing will be required.
12
2.1.3.
Reaction Kinetics
The reaction kinetics were retrieved from the literature [10]. AA referred as promising catalyst for
industrial production and the kinetics by utilising this catalyst are presented in Table 2.1 for
temperature equal to 120 oC. In this a study a model developed for describing kinetics of DCP
production assuming 1st order kinetics for all the reactions and found quiet reliable compared to the
experimental results. These kinetic values were used later from us for simulation of the process.
Table 2.1 Reaction kinetic values of chlorination of GLY at 120 oC [10].
Rate Constant k (min-1)
2.56
9.07
5.03
11.37
Reaction
1
2
3
4
2.2.
In the second step of the process dehydrochlorination of DCP occurs for the production of the final
product EPH. The base to be used is defined from the formulation of the problem as sodium
hydroxide (NaOH). The reaction taking place are the main one but also in parallel hydrolysis of DCP
occurs resulting to the consumption of value product as illustrated from Reaction 1 and 2.
1.
2.
Apparently, to avoid undesired consumption of the valuable product from hydrolysis reaction it
should be removed promptly. This can be achieved by performing the reaction in a reactive
distillation column with instantaneous removal of EPH. Reactions conditions are relatively mild at
around 60 oC and atmospheric pressure [11] and the optimal ration of base to DCP is defined at
0.89:1 obtaining 97 % selectivity to EPH and 88 % of DCP [12].
MA et.al [13] showed that both reactions can be well represented by 2 nd order kinetics using titration
technique as seen from Equations (2.3) and (2.4). These kinetic parameters were used from us for
the simulation of the reaction unit afterwards.
13
Main Reaction
OH
r 1=8.971020 e
123200
RT
[ DCP ]
(2.3)
Side Reaction
OH
r 2=5.661010 e
70790
RT
[ EPH ]
(2.4)
Where [OH-] the concentration of hydroxide ions and [EPH] the one for EPC.
2.3.
Production of Dichlorohydrins :
In this process the catalyst, glycerol and HCL are fed to a reactor where the chlorohydrination
reaction takes place. The products are subjected to distillation to remove impurities like unreacted
raw materials and undesired products. The top product from this operation is subjected to decantation
where the DCPs are separated from water [15].
Operating conditions of DCP production
Production of EPH:
14
The EPH is manufactured in two steps: the first step is reaction and extraction followed by
distillation separation train. The distillation operation can be in combination with adsorption, but this
is not the most preferred option. The reactor has to be equipped with stream stripping to remove the
EPH from the reaction environment as soon as it is formed to avoid the side reaction.
Operating conditions of EPH production [16]:
REACTORS
Excess of DCP as compared to NaOH: 0.89 effective equivalent (in order to reduce EPH
2.4.
Regarding to the first step of the process (chlorination of GLY), the catalyst can strongly influence
the efficiency of the reaction. A catalyst is characterised as successful when is active, selective to 1,3DCP and non-volatile. According to the above criteria AA seems to be the optimal choice at a
concentration around 8 % mol. HCl should be fed as a gas inside the reactor to avoid accumulation
of water and therefore slow kinetics. Water is also produced as a product of chlorination of GLY, thus
a combination of reaction and intermediate separation might be a promising solution for water
removal and lower reactor volume. The pressure of HCl and mixing intensity are highlighted as very
important parameters in relation to yield and selectivity toward DCP. HCl at 5 bar pressure can
provide very good results, whilst good mixing should be provided to overcome mass transfer
limitations. Upon the dehydrochlorination of DCP, EPH produced should be removed instantly from
the reaction system, and to that end a reactive distillation column has to be utilised. The optimum
ratio between the base and DCP was found to be 0.89:1 giving high selectivity on EPH and
conversion of DCP. Finally the kinetics of both reactions were found in the literature and will be used
for the simulation of the process on Aspen Plus.
15
16
mainly DCPs and water, but also a-MCH and b-MCH. In the next step water with
monochlorohydrins are removed giving a stream rich in DCPs which react with NaOH in the
dehydrochlorination unit to produce EPH and water. At the same time a solution of sodium chloride,
one of the products of the reaction, is removed from the bottom of the unit. Finally the separation of
EPH from water is performed in the purification unit. For the simulation Electrochemical NRTL has
chosen as base method due to the presence of electrolytes in the process, such as HCl and NaOH.
3.1.
The reaction is taking place in liquid phase and HCl decided to be fed in gas phase. As pointed out in
the previous chapter effective mixing is required in order to increase the yield and selectivity to DCP.
17
The most commonly used reactors on bench scale apparatus are either batch or semi-batch; however
these types of reactors are inappropriate for large scale production and particularly when the annual
capacity of the product is 100 kt. In industrial scale the previous types can be replaced by continuous
stirred tank reactors (CSTRs), retaining the capability of intense mixing in a continuous mode.
Initially, the reaction system was simulated on Aspen only with one CSTR but an extremely large
reactor volume was needed , ca. 360 m 3, in order to obtain the desired conversion of GLY and at the
same time the necessary mole flow of DCP for 100 kt/yr production of EPH. This result most likely
is attributed to the fact that CSTR operates at the same operating conditions (i.e. temperature and
concentration) as the exit stream. To reduce the reactor volume, CSTRs in series were simulated in
order to approximate plug flow behaviour but at the same time retaining perfect mixing. The
following configurations are based on the same principle, but lower volumes for the same conversion
can be achieved in the second case making them the preferred option.
18
R1,3 DCP
Ra MCH
k3Ca MCH
k1CGLY
(3.1)
The production of a-MCH and 1,3-DCH are 1st order reactions as mentioned before and they occur in
series. Thus by formulating the selectivity of GLY toward 1,3-DCH becomes clear that for high
concentration of GLY high selectivity to a-MCH can be achieved and this occurs in the first reaction
block where the entire stream of GLY is distributed. After the first reaction unit high concentration of
a-MCH has been obtained and therefore the process is primarily selective to 1,3-DCH in the second
reaction unit. Feed of GLY is interupted after CSTR-2 so as to speed up the kinetics of 1,3-DCH
formation and at the last unit the feed of HCl is stopped where the remaining a-MCH reacts with the
unreacted HCl. The distribution of HCl is targeting to complete consumption of GLY in the first
block, preventing 1,3-DCH formation.
19
Water removal has been pointed out as very beneficial for the kinetics of GLY chlorination and to
that end DC-1 unit is present between the two reaction blocks where 177 kmol/hr out 186 kmol/hr of
water are removed from the top stream, while the bottom stream composed of MCP, DCP and GLY
moves to the next reaction unit (CSTR-3). This amount of water removal can be achieved with a
column of 25 bubble cap trays and reflux ratio around 1.3. The downstream of the reactor is
composed of large amount of DCP, around 126 kmol/hr and therefore the yield of GLY to DCP is
estimated around 90 %. Also water (ca. 77 kmol/hr) and small amount of monochlorohydrins (ca.12
kmol/hr) are present, with negligible amounts of GLY and HCl. Table 3.1 and Table 3.2 show the
moleflow of HCl and GLY after S-1 and S-2 respectively.
Table 3.1 Stream 3 (HCl) splitting.
Stream
Molar Flow (kmol/hr)
3
285
HCl-1
107.99
HCl-2
107.99
HCl-3
53.9
HCl4
15.02
6
140
GLY-1
70
GLY-2
70
The volumes of the reaction units with the corresponding dimensions by assuming cylindrical vessel
geometries are tabulated in Table 3.3.
Table 3.3 Reaction units diamensions.
Unit
Volume (m3)
Diameter (m)
Height (m)
CSTR-1
31.5
4.4
CSTR-2
36.3
5.1
CSTR-3
47
6.6
CSTR-4
40
5.6
CSTR-5
24.2
3.4
Total Volume
179
20
Figure 3.3 Kinetics Comparison between experimental results and the developed model for
chlorination of GLY [10].
As a consequence, the reactors needed for the DCP production have very high volumes. In each
CSTR, water is being generated in the system reducing the concentration of GLY, there is non21
reacted HCl and very high pressure is needed to reduce the overall volume of the gas phase for the
non-reacted HCl.
The first solution to deal with these problems is working at very high pressures (>20 bar) therefore
the volumetric flow of HCl is reduced. However, the residence times are still high and the volume
cannot be further reduced. The idea to decrease the residence time and achieve high yields was to
increase the number of CSTR in series until the configuration assembled a more realistic PFR.
Figure 3.4 Absorption of HCl as a function of time for different pressures [3].
The model of the real PFR is developed by using many CSTR in series. As described in the literature
review chapter, the HCl is not participating on the kinetics, the flow of HCl introduced is optimized
to be the exact amount that can react in each reactor. Introducing more than required increases the
overall volume significantly and an additional separation is needed. Splitters are used to distribute
the flows of HCl. The split ratio is optimized so the outlet of each reactor does not contain unreacted
HCl, this ensures that the correct amount is used. The custom model of this reactor is shown in
Figure 3.5.
Introducing the exact amount of HCl in each reactor decreased the overall volume of reaction and
allowed to decrease the pressure of operation from 20 bar to 5 bar. All the amount of HCl has reacted
and therefore there is no gas phase in the reactor. Increasing the number of CSTRs used has shown to
improve the distribution of HCl among the reactor and reduces the overall volume and residence
times required to achieve the required yield of DCP.
22
The model of the reaction part in Aspen is as shown in Figure 3.8 and 3.9. The model is equivalent
to use a total of four PFR. The hierarchies A and B are equivalent. These blocks are composed of two
PFR in series. They are interconnected with a distillation column in the middle that extracts all the
water formed during the reaction in the first reactor and sends back the products and unreacted
species to the second reactor.
23
24
W1
39(IN)
W2
PFRA2IN
B3
PFRA1OUT
B2
40(OUT)
B1
PFRB2OUT
38(IN)
41(OUT)
PFRB1OUT
HCL
C-1
HE-1
B5
1HP
PFR1
HCL1
PFR1OUT
1HC
HIERARCHY
B2
HCL2
PRODUCTS
HE-2
GLY
B3
P-1
GLY1
PFR2
S32
1HT
GLY2
PFR2OUT
HIERARCHY
V-1
PL
16
DC-2
DC-1
DICHL
17
HE-3
PLTL
19
18
HE-4
21
25
Figure 3.9 PFR Reactor 1 and 2 in series (blocks A and B equivalents) with water extraction.
The injection point was arithmetically determined according to the volume of each CSTR respect the
total volume of the PFR. Table 3.4 and 3.5 show the injection point of HCl, the exact flows of HCl
needed to completely react, the total length of the reactors, and the total volume of each reactor.
The diameter of the PFRs is fixed at 2.5m. As can be checked in bold letters in the following tables,
the first reactor has 24 m3 and 4.89 m of length, and the second reactor has 44 m3 and 9 m of length.
Table 3.4 Injection points of HCl for the first PFR.
Reactor 1
26
VCSTR
t/h
VPFR(L) / cc
L/m
Injection / m
HCl / kg/h
HCl / L/s
1567
0.25
1567
0.02
0.01
799
36.23
1701
0.50
3268
0.05
0.04
608
27.53
1806
0.75
5074
0.07
0.06
480
21.74
1891
1.00
6965
0.10
0.09
384
17.39
1971
1.25
8936
0.13
0.12
288
13.04
2036
1.50
10972
0.16
0.14
352
15.94
2085
1.75
13057
0.19
0.17
224
10.14
2127
2.00
15184
0.22
0.21
192
8.70
2162
2.25
17346
0.25
0.24
160
7.25
2193
2.50
19539
0.28
0.27
144
6.52
2221
2.75
21760
0.32
0.30
128
5.80
2245
3.00
24005
0.35
0.33
96
4.35
V(Length) / cc
PFR2Length / m
Injection / m
HCl / kg/h
HCl / L/s
3.25
1762
0.37
0.19
13.5
0.61
3.50
3545
0.40
0.39
9.6
0.44
27
3.75
5347
0.43
0.41
12.5
0.57
4.00
7167
0.45
0.44
10.6
0.48
4.25
9002
0.48
0.47
8.3
0.38
4.50
10853
0.51
0.49
8.2
0.37
4.75
12716
0.53
0.52
57.6
2.61
5.00
14591
0.56
0.55
54.4
2.46
5.25
16477
0.59
0.58
48.0
2.17
5.50
18372
0.62
0.60
41.6
1.88
5.75
20275
0.64
0.63
36.8
1.67
6.00
22186
0.67
0.66
38.4
1.74
6.25
24105
0.70
0.69
35.2
1.59
6.50
26031
0.73
0.71
32.0
1.45
6.75
27963
0.76
0.74
28.8
1.30
7.00
29901
0.78
0.77
25.6
1.16
7.25
31843
0.81
0.80
22.4
1.01
7.50
33790
0.84
0.83
19.2
0.87
7.75
35741
0.87
0.86
22.4
1.01
8.00
37697
0.90
0.88
16.0
0.72
8.25
39656
0.93
0.91
19.2
0.87
8.50
41618
0.95
0.94
16.0
0.72
8.75
43583
0.98
0.97
12.8
0.58
9.00
44369
0.99
0.99
0.5
0.02
Plotting the injection ratio of HCl/GLY mole ratio against the normalized length of reaction (PFR1
and PFR2 length), it is obtained a logarithmic expression that relates the optimized HCl injection
divided by the GLY mole flow (140 kmol/h of GLY at the inlet of the reactors) and the inject zones
across the reactor. This would be an advantage for designing the real reactor, where the nozzles could
be distributed evenly and it can even be extrapolated to other reactor size and other production
requirements.
28
Normalized injection
Reactor 1
Logarithmic (Reactor 1)
Reactor 2
Logarithmic (Reactor 2)
Figure 3.10 Plotting of HCl injection points across PFR1 and PFR2.
HCL
-MCH
-MCH
1:3 DCP
2:3 DCP
HCL
C-1
HE-1
B5
-85.05
213
220.35
174.3
184
PFR1
HCL1
PFR1OUT
columns as seen in Figure 3.11. In the first column DC-1, water and traces of HCl are extracted from
B2
PROD
the product
mix. The P-1
inlet stream B3
of the column
stream 15 is at 130 C and at 1 bar. A partial
GLY1
HE-2
condenser
GLY
PFR2
has been
column to flash remaining HCl before
the condenser
1HT used on the S32
PFR2OUT (stream-16).
GLY2
HIERARCHY
The bottom stream is heated up by HE-4 and is sent to the second column DC-2, the desired product
V-1
of the first reaction, DCP, are retrieved on stream 20 with 99.5 % purity.
PL
16
DC-2
DC-1
DICHL
17
HE-3
PLTL
19
18
HE-4
21
Number of stages
Feed stage
Mole recovery
Sensitivity analysis was done to find the optimal parameters considering the above criteria.
Optimization was performed by varying number of stages, feed stage and reflux ratio, the minimum
duties are found (iterative process). The composition profile of the components of interest must
reveal a changing profile across the column, without pinches (feed stage not optimal) or stages at
30
constant compositions (excess of stages). For the recovery, the bottoms/distillate rate was varied to
obtain maximum recovery of desired product.
Sieve trays are used for the columns due to their low cost, low maintenance requirements, low
fouling tendency. The design specs were applied to mole recovery and mole purity of 1,3-DCP in the
first column and second column respectively, since that is most desired product. The Table 3.7 and
3.8 give information about the design specs and dimensions of the columns.
Table 3.7 Design spec of the columns
Column
Design Spec
DC1
DC2
Bottom: 0,999
Recovery and purity of 1,3-DCP in
Distillate: 0,99
Table 3.8 Dimensions of distillation columns
Column Parameters
Reflux ratio
Number of stages
Feed stage
DC1
0.5
10
5
DC2
0.5
25
18
The energy consumption of the columns were minimized is to be noted since it is an important
factor considering the overall economics of the process. The Table 3.9 shows the condenser and
reboiler duties of the columns.
Table 3.9 Energy Requirements of the columns
Column
C1
C2
3.2.
Qc
(MW)
-0.80
-2.61
Qreb
(MW)
1.22
0.60
Tc
(C)
98.88
172.52
Tr
(C)
174.52
215.75
Dehydrochlorination of DCP
Dehydrochlorination of GLY dichlorohydrin is the process in which the DCPs react with a base to
form EPH, salt and water. In industry this process is carried out with lime milk. It creates many
ecological problems caused by waste water containing calcium chloride. It is advisable to replace the
31
lime milk by NaOH or catholyte. The waste water after the concentration and purification could be
recycled to electrolysis [26].
RDISTILL
TPROD
DC-2
B1
DICHL
DCHLFEED
NAOH
BTM
21
1 bar
Number of stages
10
Feed stage
Distillate rate
Reflux ratio
365 kmol/hr
0.1
Reboiler duty
6.11 MW
Condenser duty
-4.7 MW
32
Temperature (feed)
63C
Temperature (top)
88 C
Temperature (bottom)
Reaction zone (stage
numbers) Time
Residence
148.8 C
Stages 4-6
10 mins.
In the reactive distillation model, either the residence time or the liquid hold up can be specified. The
reaction stages are from 4 to 6, with 10 minutes of residence time [16]. The thermodynamic property
method used to carry out this reactive distillation is Electro-NRTL. The separation of EPH and water
is an important aspect of this process since EPH forms an azeotrope with water at about 88 C and
101.3kPa. Aspen databases does not include the binary interaction for this mixture. In order to
achieve a proper simulation the parameters for the azeotropic distillation have to be introduced in the
properties environment.
Table 3.11 Binary parameters for NRTL method for EPH-water azeotropic distillation [23]
The top of this column i.e. the top product consist mainly of water and EPH. Sodium chloride
solution was obtained at the bottom. Design specifications were employed to achieve maximum
recovery of EPH at the top by varying the distillate rate. The yield of EPH was found to be 99%.
Almost no GLY was formed in the system.
3.2.1.
The last part of GTE process is the separation of water from the final product, EPH. As mentioned
previously these two components form an azeotrope at 88 oC, atmospheric pressure. The traditional
techniques to tackle with azeotrope via using distillation are pressure swing, when the equilibrium is
sensitive to pressure changes, entrainers or to resort to modern types of separation such as
membranes [18]. After assigning the binary NRTL parameters to Aspen plus, T-x-y diagram retrieved
as illustrated in Figure 3.13, whilst Figure 3.14 shows the corresponding graph derived from
experimental results. Apparently, the two graphs are almost identical indicating the azeotrope
composition to be at 0.34 mole fraction of water and 0.66 for EPH. This observation leads to the
33
conclusion that a promising separation can be simulated on Aspen Plus, but besides this fact , it is
evident that the forming azeotrope is heterogeneous with the formation of two liquid phases, one
organic and one aqueous.
Figure 3.13 T-x-y EPH/Water diagram obtained from Aspen Plus simulator after the assignments of
binary parameters.
For the simulation of the 2 nd separation train NRTL base method employed since is capable of
predicting vapour-liquid-liquid equilibrium. After the above observation the separation becomes
simpler due to ability to cross distillation boundaries in the case of heterogeneous azeotropic
distillation. The proper piece of equipment in order to achieve this is a simple decanter while phase
splitting is not constrained by distillation boundaries.
34
1,00
0,95
0,90
0,85
0,80
0,75
0,70
0,65
0,60
0,55
0,50
0,45
0,40
0,35
0,30
10
Stage Number
Figure 3.17 EPH liquid mole fraction per stage in unit DC-3.
35
The distillate of DC-1 is driven to the first decanter where significant amount of water (73.5 kmol/hr)
is removed due to the immiscibility of the two liquid phases. With utilisation of one more column
(DC-2) and a second decanter complete separation of EPH, retrieving 123.5 kmol/hr out of 125
kmol/hr of product with 99.1% purity. In such a way the principle of crossing the distillation
boundaries with decanters in the case of azeotrope is verified and the separation becomes simple
without any need of introduction of new materials (e.g. entrainers) to the process or pressure change.
Finally the relatively high difference in the boiling point of the azeotrope and EPH allows the usage
of small columns and therefore low capital cost.
Table 3.12 Column Input Specifications
Parameter
DC-1
DC-2
Number of stages
10
10
Distillate rate(kmol/hr)
133
25
Reflux ratio
0.1
0.5
Feed stage
65
65
Pressure (bar)
36
4.1.
The reaction unit for the chlorination of GLY was simulated by many CSTRs in series as presented
on Chapter 3; however in reality four PFRs will be utilised and thus the installed equipment cost
should be estimated accordingly. For that purpose Guthrie method has been employed by using
Marshall and Swift (M&S) indices and costing was carried out by considering every PFR as
horizontal pressure vessel. M&S indices could not be retrieved from the literature for 2015 and a
sufficiently high value (1800) was assumed compared to M&S indices in 2007 (ca. 1363) [19] in
37
order to avoid underestimation of the cost. Moreover, 30 % of the calculated cost was added to the
final price, taking into account the coating (i.e. glass line coating) as well as additional charges for
piping and construction. The total installed cost of the reactor found to be 1.04 M$ and the installed
cost of each individual unit is shown in Table 4.1, whilst the sizing and the installed cost of the
columns is demonstrated in Table 4.2.
Table 4.1 Dimensions PFR reactors for Chlorination of glycerol.
PFR1A
PFR2A
PFR1B
PFR2B
Volume (m3)
24
44
24
44
5.7
5.7
Diameter (m)
2.5
2.5
2.5
2.5
Length (m)
4.8
9.0
4.8
9.0
Installed Equipment
15.2
24.8
15.2
24.8
Cost (k$)
Table 4.2 Costs and sizing of distillation columns and reactive distillation (RDC-1).
DCW-1
DC-1
DC-2
RDC-1
DC-3
DC-4
Diameter (m)
1.22
0.91
1.37
1.83
1.37
0.76
Number of trays
33
12
12
12
12
12
0.61
0.61
0.61
0.61
0.61
0.61
Height (m)
20.13
7.32
7.32
7.32
7.32
7.32
-2.86
-0.80
-2.61
-4.70
-1.72
0.55
Condenser duty MW
1.97
1.22
0.60
6.12
2.10
0.55
586
520
557
724
557
442
38
4.2.
It is assumed that the raw materials enter the plant at 30C and 1 bar. They need to be compressed to
the working pressure of the reactor (5 bar). The details for the equipment needed is shown in Table
4.3 and 4.4.
Table 4.3 Costs and sizing of pressure changers for raw materials
Isoentropic compressor HCl
478
Efficiency
0.8
Outlet pressure
Outlet temperature
kW
Electricity
1.5
kW
Flow
l/s
bar
Outlet pressure
bar
250
NSPHa
8.5
Isentropic outlet
207
Head
34
temperature
Equipment cost
1.1
M$
Equipment cost
80
k$
Installed cost
5.1
M$
Installed cost
140
k$
Installed cost / $
Capital cost / $
SW.DW-reflux pump
2.85
32500
5300
SW.B1 pump
4.62
90300
66200
DC-1-reflux pump
0.83
28200
5100
DC-2-reflux pump
13.21
43900
6123
DC-3-reflux pump
3.49
33900
5900
DC-4-reflux pump
0.89
31700
5100
RDC-1-reflux pump
10.00
40100
8100
4.3.
The results for required heat exchangers and decanters are shown in the tables below.
Table 4.5 Costs and flows of additional pumps.
39
HE-1
HE-2
HE-3
HE-4
HE-5
HE-6
HE-7
SW.HE
13.9
6.2
3.8
53.2
12.4
36.8
4.7
56.5
Capital cost / $
10900
10800
8500
8400
10800
15200
9600
24800
Installed cost / $
61600
63200
61300
61200
60700
74300
58800
103200
504
128
162
658
-1485
213
1925
Energy / kW
-432
D-3
D-2
Liquid volume m3
170
170
170
Vessel diameter / m
9.8
9.8
9.8
Heat duty / kW
148
278
1.2
Design temperature / C
122
121
157
Operating temperature / C
88
87
130
Capital cost / $
15400
15400
15400
Installed cost / $
119900
116200
117600
40
5. Economic evaluation
The selling price for conventional EPH ranges from 1700 to 2200 $/ton in the Asian market. In this
section, this prices will be compared to the required selling price and to recommended selling price.
5.1.
As the required amount of hydrogen chloride is very high (85848 kton/year) for the production of
100kton/year of EPH, ideally a neighbour plant which produces HCl may be required. However, in
order to make an economic evaluation it is necessary make assumptions to establish a price for each
stream. This price was extrapolated from the price of 36% hydrochloric acid (100$/ton), dividing by
0.36 (concentration), the price per ton HCl is extracted (277$/ton). Assuming a factor of 30% for the
separation of hydrogen chloride from water, the value of the HCl stream was obtained (360$/ton).
The price of solid pearls of pure NaOH (300$/ton) was used to extract the price of the NaOH (aq)
41
30% mol (120$/ton). The refined vegetal glycerol price ranges from 700-800$/ton [24] in the Asian
market. The summary of the prices introduced is shown in the following table:
Table 5.1 Raw materials price
Raw materials price
HCl
360
$/ton
GLY
800
$/ton
120
$/ton
5.2.
Results
After introducing the raw materials price, extracting the price of the CSTR in series and adding the
price for the PFR reactors it is possible to use ASPEN economics to obtain all the desired economic
information.The utility costs are found in Table 5.2.
Table 5.2 Raw materials price
Utility
Fluid
Electricity
Rate
Units
Cost per
Cost
690.5
kW
Hour
77.1
Units
$/ hr
Cooling Water
Water
1065.6
m3/hr
33.7
$/ hr
Steam @690KPA
Steam
19.7
ton/hr
353
$/ hr
Steam @1135KPA
Steam
5.74
ton/hr
123
$/ hr
Steam @2760KPA
Steam
5.20
ton/hr
134
$/ hr
42
Price
30.0
163.3
140.8
199.6
6.3
20
4.3
10.7
1633
1800-2,500
The required selling price (1633 $/ton) was calculated by dividing the total operating cost of the
plant (163 M$/year) by the production capacity 100,000 ton/year.
The percentage of investment returned each year is calculated in aspen assuming the total cash flow
for each year. Taking into account the total expenses and the total income, the percentage of
investment returned each year is defined as return over investment. Assuming a final recommended
selling price for the EPH in Asia of 1800 $/ton [25], the return over investment (R.O.I) is
33%/year.
Results of ASPEN economics for cash flows and detailed revenues and costs are found in appendix.
Both EPH and GLY prices vary significantly over the time. In order to study the viability of the
project a sensitivity analysis was performed. This analysis is shown in Figure 5.1.
43
Using the relation found on Figure 5.1, it is possible to predict the minimum required selling price
for EPH. This process is economically viable when the price of GLY in the market is lower than
900$/ton. The price market trend for glycerol is shown in Figure 5.2.
44
45
Conclusions
has been estimated 3 years for 1800 $/ton EPH selling price, highlighting GTE process as
economically viable and a promising alternative.
For the first step of the process (i.e. chlorination of GLY) two reactor configurations have been
proposed and intermediate water removal is strongly recommended in order to achieve smaller
reaction volume. Custom PFR model is suggested for further reduction of residence times and
therefore reaction volume. For the second step, a reactive distillation column is used for fast removal
of EPH and improved yields. The purification of EPH has been done with consecutive decanters and
distillation column in order to tackle the heterogeneous azeotrope, giving 99% pure product (EPH).
The overall yield of GLY to EPH found to be 89%.
Pinch point analysis including only the heat exchanger units of the process showed annual savings
ca. 168 k$/year in the utility costs. More thorough heat integration including the column of the
process is recommended for further reduction.
Appendix
The following figures (Figure 1, Figure 2 and Figure 3) represent the 3D design regarding the first
proposal of the reaction system for chlorination of GLY from two different perspectives. The first
reaction block is composed of two CSTRs in series, focusing on the production of a-MCH. GLY is
fed only to the first reaction unit after Splitter-1, whilst HCl is fed to the first five reactors for the
reasons explained on Chapter 3. In order to reduce the number of units, reaction towers with stages
will be utilised. In each stage a downcomer will be designed for the flow of the reaction mixture
from on stage to the other so as to achieve the required residence time for every reactor. GLY lines
are painted in red colour and HCl lines are in blue. In each reaction column a shaft is employed
having had multi-impellers incorporated.
47
48
(1)
Where H is the length of the reactor, D the diameter and Cp0 the f.o.b. cost in 1968.
Then the installed cost can be calculated from Equation (2),
CBM [( FBM 1) Fm FP ]Cop
(2)
Where FBM is a correction factor equal to 4.23, F m the material correction factor which is equal to 1
for Carbon Steel and FP the pressure correction factor equal to 1.05 for pressure less or equal to 6.7
49
bar. The calculated cost is for 1968 and by using Equation (3) the corresponding for 2015 can be
found.
(3)
Tin (K)
Tout (K)
Cp (kJ/kmol K)
F (kmol/sec)
FCp (kW/K)
H2
523
363
28.8
268
2.1
H21
446
333
167.2
126
5.8
H28
472
338
141
217
8.5
H33
403
338
236.1
58
3.8
H35
361
353
183.9
25
1.2
C4
303
363
217.3
140
8.4
C14
393
403
137.9
198
7.6
C18
448
468
172.4
140
6.7
C25
361
472
54.3
365
5.5
C31
361
403
54.3
133
From the inlet and outlet temperatures of hot streams is evident that the requirements of cold utilities
are significantly higher than the requirements for hot utilities. Figure 4 represents the process
streams as vectors and the temperature scale for cold streams is shifted by min as pinch point
analysis dictates. The problem, as it can be observed is divided into fifteen temperature intervals (I1,
50
I2 etc.) where hot streams and cold streams are able to exchange heat and heat surplus can be
transferred from one interval to the other owing to the driving force or i.e. temperature gradient.
H2
523 K
I-1
492 K
503 K
472 K
I-2
468 K
488 K
I-3
472 K
452 K
I-4
468 K
448 K
I-5
446 K
426 K
I-6
433 K
403 K
I-7
413 K
393 K
H28
C18
H21
C14
I-8
403 K
383 K
I-9
383 K
363 K
I-
381 K
361 K
H33
C25
10
I-11
I-12
I-13
I-14
C31
363 K
343 K
H35 361 K
341 K
353 K
333 K
338 K
318 K
51
I-15
333 K
303 K
C4
Qint erval
FCH ,i
hot streams ,i
FC
int erval
C,j
hot streams , j
int erval
(4)
Where FCH,i is the heat capacity of the hot stream i in the specific interval, FC C,i the heat flow
capacity of cold stream j and interval the temperature difference between the limits of the interval.
The heat duty of each interval was calculated and afterwards cascade calculations were performed so
as to define the minimum hot and cold utilities of the process as demonstrated in Table 2.
Table 2 Minimum hot and cold utilities estimation.
Interval
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FCp,interval
2.1
-3.3
-10
-1.5
5.1
11
3.4
9
12.8
4.3
11.8
9.7
11
9.7
-2.5
interval (K)
31
4
16
4
22
13
20
10
20
2
18
2
8
15
5
Qinterval (kW)
Cascade
+66.7
-13.4
-160.9
-6.2
+113.3
+143.2
+67.9
+90
+256.5
+8.7
+214
+19.4
+88.1
+146
-12.9
Qj (kW)
0
+113.8
+66.7
180.6
+53.3
167.2
-107.6
6.2
-113.8
0
-0.56
113.3
+142.6
256.5
+210.6
324.5
+300.7
414.5
+557.2
671.0
+565.9
679.8
+779.9
893.8
+799.4
913.3
+887.5
1001.4
+1033.5
1147.4
+1020.6
+1134.5
As it can be observed the heat duty of each interval is calculated by Equation 4, and fourth column
is derived by cascade calculation of column 3. Negative values on column 4 imply heat transfer from
lower temperatures to higher temperatures, violating in such a way the second law of
thermodynamics. The most negative value (-113.8 kW) is observed in the fourth row and thus in
52
order to obstruct further violation of the second thermodynamic law this amount of heat should be
provided as an absolute value to the first interval (I-1) as being done in the sixth column. This
amount of heat simultaneously is the minimum requirements in hot utilities. The minimum amount
of cold utility is found by proceeding again with cascade calculations and it can be seen at the bottom
cell of the sixth column (+1134.5 kW). Finally by definition the point where the flux of heat equals
zero is the pinch point and it is located at interval 4 or at 472 K for hot streams and 452 K for cold
streams; because of the zero heat flux in the pinch point, the problem now is separated into two
different problems, namely above pinch point and below pinch point.
The minimum hot and cold utilities have been found; however further analysis is needed in order to
define the minimum number of heat-exchange units and also the way at which the different streams
should be combined together for the achievement of minimum utilities. To that end the problem is
separated to two sub-problems, namely above and below the pinch, and both of them are analysed on
the following sections.
N HE ,AP NS,AP 1 4 1 3
Where NHE,AP the number of heat exchange units and NS,AP the number of streams above pinch point.
Taking into account one more unit for the hot utility above pinch, the predicted number of units is
four. Figure 5 represents the problem above pinch. Stream H28 has 8.5 kW/K flow heat capacity, a
higher number than the two cold streams. Therefore, this stream cannot be utilized for heating up the
cold streams C25 and C18 which have lower flow heat capacities [20]. Splitting of stream H28 into
two streams with smaller flow heat capacities (8.5-x and x) is the necessary action to enable heat
transfer.
53
Tout ,C 25 469 K
Stream H28 is divided into two streams with flow heat capacities 8.5-x and x. Presuming that we
want to satisfy stream C25 with the stream of x flow heat capacity. The value of x can be found from
the energy balance between the two streams as follows,
54
N HE ,BP N S,BP 1 9 1 8
Therefore eight heat exchange units plus one unit for the utility are expected and this result can be
verified by Figure 6 where there are 9 units in total. The minimum cold utility requirements can be
found by summing up all the cold utility duties from Figure 6, and the total duty is found equal to
1134.1 kW, indicating optimum stream combination. Having performed pinch point analysis, the last
step is to provide some rough estimations of annual savings ($/year) achieved by applying the
technique in practice.
55
56
Price ($/tn)
0.06
Cost ($/tn)
3.5
Cp (kJ/kg K)
4.2
hvap (kJ/kg)
3.8
C)
Medium Pressure steam (MPS,11 bar-
2.54
184 oC)
Low Pressure steam (LPS,6 bar-160
18
2.15
C)
The heat content of each process stream can be estimated by Equation 5, depicting the amount of
heat that should be added or removed from the stream so as the target temperature to be reached. The
annual mass flow rate of water is calculated by Equation 6 and the one for steam from Equation 7
and subsequently the annual cost of utilities.
Qstream FC p stream
g
(5)
(6)
(7)
Where FCp the flow heat capacity of the stream, m cw the mass flow of cooling water, m steam the mass
flow of steam and hvap the latent heat of steam as given in Table 3.
57
Table 4 shows the calculation of the annual utility cost without heat integration of the process and it
is estimated around 287 k$/year. By performing pinch point and combining hot and cold streams this
cost can be reduced by ca. 56 % as demonstrating in Table 5.
Utility
Qstream (kW)
Utility Mass
Cost ($/year)
Flowrates
H2
H21
H28
H33
H35
C4
C14
C18
C25
C31
(tn/year)
344
258962
662
497763
1139
855827
248
186247
10
7672
507
5898
76
885
134
1510
611
6890
84
980
Total annual utility cost M$
CW
CW
CW
CW
CW
LPS
LPS
HPS
HPS
LPS
15537
29865
51349
11174
460
20644
3100
27197
124024
3432
0.287
Qutility
1134.6
116.5
Cost ($/year)
102230
23626
0.12
58
Changes in the feed flow rate for example changes in the temperature or feed composition.
Changes in the conditions of utilities like steam or cooling water temperature fluctuations.
Ambient conditions in the environment like temperature fluctuations or moisture content.
The basic parameters under consideration for designing a control scheme for a process are:
Temperature
Pressure
Level
Flow
The process scheme under consideration consists of various equipment supposed to be working at
specified conditions. This equipment requires a control mechanism so that desired quality of product
is obtained. The main equipment under consideration for this case are the reactors, distillation
columns, the heat exchangers and the decanters.
Control of Reactors
The reactor system consists of the PFRs and the reactive distillation column (which is a hybrid vessel
consisting of a reactor and a distillation column in one equipment). As mentioned previously, the
main parameters considered for the control of the PFRs is the pressure in the vessel, and the level in
the vessel. The temperature of the vessel is controlled by using a jacketed vessel. The flow of the
coolant in the jacket is the manipulated variable used for the control of this parameter. The pressure
of the vessel is controlled by regulating the feed flow of the HCl gas in both the vessel, at the valve
after the splitter. The level of the vessels is controlled by the product outflow from the vessel. The
flow to these vessels is kept in a ratio which is already specified in the splitter equipment.
The reactive distillation column is slightly different equipment since it combines two unit operations
in a single vessel. The temperature of the reactive zone is regulated by the flow of dichlorohydrins to
the column. The composition of the product at the top is regulated by the flow of the NaOH to the
column. The control of this equipment is otherwise very similar to a normal distillation column
which is explained in the next section.
59
UNITS
Weeks/period
Period
Period
Period
Percent/period
Percent/period
Percent/period
Cost
Cost/period
Cost/period
Cost/period
Cost/period
Percent/period
Percent/period
Period
Percent
Percent/period
Percent/period
Percent/period
Percent/period
Percent/period
Period
Period
Period
Percent/Period
Period
Percent/Period
Period
52
20
0.846154
0.929487
5
25
50
3.06E+07
1.41E+08
2.00E+08
2.37E+06
6.33E+06
20
5
40
1.2
30
20
Straight Line
1
5
5
3.5
3
3
1
10.5
30
8
0.326923
62
Cost/period
Cost/period
2.06E+06
305714
CASH FLOW
1st year
2nd year
3rd year
4th year
5th year
6th year
7th year
8th 10
10th year
Period
R (Revenue)
DEP (Depreciation Expense)
E (Earnings Before Taxes)
TAX (Taxes)
NE (Net Earnings)
TED (Total Earnings)
TEX (Total Expenses (Excludes
-4.50E+07
817172
-4.58E+07
0
-4.58E+07
-4.50E+07
5.98E+07
4.52E+07
817172
4.44E+07
1.78E+07
2.66E+07
2.75E+07
1.75E+08
5.02E+07
817172
4.94E+07
1.97E+07
2.96E+07
3.04E+07
1.81E+08
5.55E+07
817172
5.46E+07
2.19E+07
3.28E+07
3.36E+07
1.87E+08
6.11E+07
817172
6.03E+07
2.41E+07
3.62E+07
3.70E+07
1.94E+08
6.71E+07
817172
6.63E+07
2.65E+07
3.98E+07
4.06E+07
2.00E+08
7.36E+07
817172
7.27E+07
2.91E+07
4.36E+07
4.45E+07
2.07E+08
8.04E+07
817172
7.96E+07
3.18E+07
4.78E+07
4.86E+07
2.15E+08
8.77E+07
817172
8.69E+07
3.48E+07
5.21E+07
5.30E+07
2.22E+08
-4.50E+07
1.48E+07
2.75E+07
2.38E+08
3.04E+07
5.16E+08
3.36E+07
8.62E+08
3.70E+07
1.29E+09
4.06E+07
1.82E+09
4.45E+07
2.46E+09
4.86E+07
3.25E+09
5.30E+07
4.20E+09
Cash Inflows)
PVI (Present Value of Cumulative
1.23E+07
1.65E+08
2.99E+08
4.16E+08
5.18E+08
6.08E+08
6.86E+08
7.55E+08
8.15E+08
Cash Inflows)
PVOP (Present Value of
4.98E+07
1.84E+08
3.00E+08
4.01E+08
4.88E+08
5.64E+08
6.30E+08
6.87E+08
7.37E+08
4.98E+07
1.84E+08
3.00E+08
4.01E+08
4.88E+08
5.64E+08
6.30E+08
6.87E+08
7.37E+08
Cash Outfows)
NPV (Net Present Value)
-3.75E+07
-1.84E+07
-820491
1.54E+07
3.02E+07
4.38E+07
5.63E+07
6.76E+07
7.78E+07
33%/year
63
References
[1]
Solvay.http://www.solvaychemicals.com/EN/products/chlorinated/Allylicproducts/Epichloro
hydrin.aspx. http://www.solvaychemicals.com/. [Online] May 2013.
[2]
Guan, Eric Linak with Akihiro Kishi and Maoshi. July 2014. CEH Report Epichlorohydrin:
IHS Chemicals, July 2014.
[3]
[4]
[5]
[6]
[7]
[8]
64
[9]
Sang Hee Lee a, Sun Ho Song a, Dong Ryul Park a, Ji Chul Jung a, Ji Hwan Song b, Sung
Yul Wooc,Won Seob Song c, Myong Suk Kwon c, In Kyu Song a,. 2008. Seoul : Catalysis
Communications, 2008.
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
Fogler, Scott. Elements of Chemical Reaction Engineering. Michigan : Prentice Hall, 1989.
[18]
Smith, Robin. 2005. Chemical Process Design and Integration. Manchester : Wiley , 2005.
[19]
[20]
Gavin Towler, Ray Sinnot and Gavin. 2010. Chemical Engineering Design. Oxford : BH
Elsevier, 2010.
[21]
J.M. Smith, H.C.Van Ness, M.M. Abbott. 2005. Introduction to Chemical Engineering
Thermodynamics. New York : McGraw Hill, 2005.
[22]
Thielemans, Geert L.B. 2014. Lecture Notes Process Design. Eindhoven, 2014.
65
[23]
Qun Yue, Jia-wen Zhu, Yan-yangWu, Xiang-qian Yuan, Liang Ma. Liquidliquid equilibria
and vaporliquid equilibria for the binary system of epichlorohydrin and water. Shangai :
Fluid Phase Equilibria, 2009.
[24]
[25]
[26]
66